Your Tampa, FL, HVAC & Electrical Experts
Air Bros Air Conditioning & Heating is proud to be part of the city of Tampa, FL. As a major metropolitan area, Tampa presents unique challenges and demands when it comes to home comfort. Whether you live in a historic bungalow in Seminole Heights, a modern condo in Channelside, or a spacious family home in New Tampa, we have the expertise and experience to keep your indoor environment comfortable year-round. Our team of skilled technicians is dedicated to providing top-quality HVAC solutions tailored to the specific needs of Tampa residents and businesses.
Call us at 727-217-6148 or contact us online for help in Tampa, FL.
Comprehensive HVAC Services in Tampa
We offer a full range of heating and cooling services designed to meet the diverse needs of Tampa homeowners and businesses.
- Stay Cool in the Summer: Tampa summers are no joke! We offer comprehensive air conditioning services, including repair, installation, and maintenance for all AC makes and models, to keep your home cool and comfortable even on the hottest days.
- Cozy Up in the Winter: Don't let the occasional cold front leave you shivering. Our heating services cover everything from furnace repair and heat pump installation to preventative maintenance, ensuring your home stays warm and cozy all winter long.
- Breathe Easy: Improve your indoor air quality and create a healthier home environment with our air quality solutions. We install dehumidifiers to control humidity and UV light air purifiers to eliminate airborne contaminants.
- Optimize Your Airflow: Ensure your HVAC system is running at peak efficiency with our ductwork services. We can repair leaks, address damage, and design a new ductwork system that's optimized for your Tampa home.
Our experienced technicians are skilled in all aspects of HVAC service and are dedicated to providing top-quality workmanship and customer care.
Why Choose Air Bros in Tampa?
- Your Tampa HVAC Experts: We know Tampa! Our team understands the unique needs of homes and businesses throughout the city, from historic bungalows to modern high-rises.
- Always On Time: We value your time and strive to provide prompt and reliable service. We offer same-day service for AC emergencies and prioritize quick response times for all your HVAC needs.
- Skilled and Experienced: Our technicians are highly trained and experienced in all aspects of HVAC service, ensuring you receive top-quality workmanship on every job.
- Honest and Transparent: We believe in upfront pricing with no hidden fees or surprises. You'll always know exactly what to expect.
- Your Comfort is Our Goal: We're dedicated to ensuring your complete satisfaction with our services and your home comfort.
Contact Air Bros Today!
We're your one-stop shop for all your HVAC needs in Tampa. Whether you're facing an AC emergency, need a new heating system installed, or simply want to schedule routine maintenance, our team is here to help. Contact us today for a free consultation and let us show you why we're the trusted choice for home comfort in Tampa!
Call us at 727-217-6148 or contact us online for help in Tampa, FL.
Recent Jobs and Reviews in Tampa, FL
Job Locations and Reviews
Upon my inspection, found system completely out of refrigerant and the condenser has a bunch of oil underneath it. System is 15 years old Sent quotes for a new system install
Upon my inspection, I found system #2 for the 2nd floor had a weak capacitor, dirty condenser coils, and low on refrigerant. Cleaned condenser coils, changed capacitor, and added 1lb of refrigerant. System is now cooling with a perfect 20° temperature split. Will send quote for duct work to add a supply to the master bedroom as well as moving the other with a new supply grill for aesthetics. System #1 for the main house is low on refrigerant. Added 1 lb and client wants to wait to see what it does to determine if they would rather invest into a new system. Amp draws are good. Drain line and primary drain pan is now clean and treated. Rinsed condenser coils. System charge is indicating low on refrigerant based on subcool being at 4 and target is 8. Sending quote for system replacement as an option. System is cooling at this time.
Downstairs clogged drain. Cleaned drains on both systems. Verified proper operation
Upon my inspection, I found an intermittently backed up drain line issue. Cleaned and treated drain line/drain pan. Will monitor situation and possibly add a p-trap to the drainage system if issue reoccurs soon. Amp draws on compressor and fan motor are good. Capacitor is within factory specs. System is cooling at this time with a 20° temperature split Recommendations: - condenser chemical coil cleaning. - Maitenence plan
Replaced bad cap no further issues
On arrival found unit with clogged drain and water in float switch causing unit to shut down intermittently. Cleared pan and drain. Added chemical to help prevent growth. Found unit sweating in encapsulated attic. Made client aware that a dehumidifier should be added to prevent sweating and excess moisture. Will submit estimate for dehumidifier and enlarging duct to bedroom.
System is in good working order. Amp draws are good Pressures are good Temp split is good at 18° Cleaned and treated drain line/drain pan Lightly cleaned evaporator coils Cleaned condenser coils Recommended a high voltage wire repair on the seal tight connector and the disconnect box mounted to the building. Made necessary repairs to prevent any future issues. System is cooling properly at this time.
Replace txv, drier and recharge system Return repair -recovered refrigerant -replaced indoor txv -replaced outdoor filter drier -pressure test system -vacuum system -charged system 410a (180oz) Verified system is operating
Found system not cooling due to bad compressor contactor. I replaced and checked operations. Unit is now cooling properly.
Upon arrival found unit not cooling due to failed outdoor capacitor. Found outdoor coils impacted with dirt/debris. Cleaned outdoor unit coils and interiors. Changed capacitor and verified operations. Unit is currently cooling and working within manufacture specifications.


On arrival found upstairs unit low on refrigerant and a possible cause for system to not keep up during heat of day. Added refrigerant back to factory specs. Inspected systems. Units are cooling at this time.


No cool Homeowner says recently system doesn’t cool the house well and never shuts off. Found weak capacitor and replaced. Blower motor runs continuously. Issue was constant power to heat, causing blower motor and heater to run, even when system is set to cool. Thermostat has an internal short which is feeding 24v to heater System is not running upon departure because homeowner took old thermostat and returned it to the store for a new one. Homeowner declined estimate for us to install thermostat and will have his son do it for him. Advise homeowner if everything is running fine after he installed new thermostat I recommend having maintenance done in the next couple months so that we can check over the system again
member maintenance performed full system maintenance. Checked refrigerant pressures and air temperature. Checked all wiring and electrical components. Found both capacitors for blower and compressor weak. Replaced capacitors during today’s maintenance. Flushed and vacuumed condensate drain line. Treated evaporator coil pan with viper spray and left pan tabs. Air handler interior is clean. The system is running well at this time.
Full system maintenance- 1 central system & 1 mini split Central- Checked refrigerator pressures and air temperature split. Flushed vacuumed and treated condensate drain line. Tested capacitor. Tested float switch. Checked contactor contactor was heavily pitted recommended replacement. Homeowner decided to move forward with contactor replacement during today’s maintenance. blower wheel is dirty provided estimate for cleaning, homeowner is not interested at this time. Removed outdoor fan and washed condenser coil/unit. Mini split- Removed and cleaned filters. Coils in head unit do not have any buildup. Washed outdoor condenser coil/unit. Unable to check refrigerant pressures as there is a leak from the Schrader core. Brought this to the homeowners attention and advised to fix this issue we would have to remove refrigerant charge, homeowner declined. sent estimate for two system maintenance membership
Member maintenance Checked refrigerant pressures and air temp split. Air handler interior is clean. Flushed vacuumed and treated drain line. Tested float switch. Checked electrical components in condenser. Tested capacitor- capacitor is weak reading 34/40 mfd. Replaced capacitor and tested system function after repair.
Clean drain Add clean out Cleaned pan as well. Checked full operation. No issues at this time
member maintenance Checked all wiring and electrical components. Checked refrigerant pressures and air temperature split. Cleaned flushed and vacuumed condensate drain line and evaporator coil pan. Blower wheel and evaporator coil are dusty. Tested capacitor. Removed lizards from defrost board. Performed full duct inspection because homeowner was concerned she may have a disconnected duct. All ducts are intact
Installation of Ruud 3 ton 19 SEER SD Invertor (variable speed AH) 10 year parts warranty 3 year labor warranty
Drain line backed up and caused secondary pan to back up. Cleared drain line, primary drain pan, secondary drain pan. Primary drain pan is starting to rust/crack. This would cause water to fill secondary drain pan. Unit is currently cooling
Clean clogged drain line and pan
Found no issues. Unit has 18°split. I checked pressures and temps. No issues found unit cooling best as possible. Advised client on other solutions or ways to keep home cool during peak heat
Replaced bad afci 15amp breaker in panel with new one (video) Installed new 2 pole 45amp breaker for correct wire connection (to much exposed copper out of breaker connection) Installed new ac disconnect for air handler with cover plate Removed exterior recep capped wires and installed wp blank cover Installed Knock out seal on side of exterior camper plug


3.5T Lennox HP Complaint about power bill being high. Previous contractor here 2 weeks ago. Found new stat installed, hard start kit installed, and leak bubble search left behind. Unit is currently operating within factory specs. Checked amp draws and temp splits. Inspected coils and filter. Bacterial growth starting to accumulate inside air handler


Full system tuneup (2 Systems) Wiped Down Air Handler Checked cap mfd Checked contactor Inspected wiring Compressor amps Motor amps Cleaned condenser coils Cleared drain line and pan Checked refrigerant pressures Checked blower amps Checked filter Thermostat operations Checked heating and cooling Unit is operating at this time
Full system tuneup Wiped Down Air Handler Checked cap mfd Checked contactor Inspected wiring Compressor amps Motor amps Cleaned condenser coils Cleared drain line and pan Checked refrigerant pressures Checked blower amps Checked filter Thermostat operations Checked heating and cooling Unit is operating at this time *Estimate for new thermostat and solution drain feeder *Growth accumulating on blower wheel *Need to size up wiring and breaker to install larger heater kit