Your Tampa, FL, HVAC & Electrical Experts

Air Bros Air Conditioning & Heating is proud to be part of the city of Tampa, FL. As a major metropolitan area, Tampa presents unique challenges and demands when it comes to home comfort. Whether you live in a historic bungalow in Seminole Heights, a modern condo in Channelside, or a spacious family home in New Tampa, we have the expertise and experience to keep your indoor environment comfortable year-round. Our team of skilled technicians is dedicated to providing top-quality HVAC solutions tailored to the specific needs of Tampa residents and businesses.

Call us at 727-217-6148 or contact us online for help in Tampa, FL.

Comprehensive HVAC Services in Tampa

We offer a full range of heating and cooling services designed to meet the diverse needs of Tampa homeowners and businesses.

  • Stay Cool in the Summer: Tampa summers are no joke! We offer comprehensive air conditioning services, including repair, installation, and maintenance for all AC makes and models, to keep your home cool and comfortable even on the hottest days.
  • Cozy Up in the Winter: Don't let the occasional cold front leave you shivering. Our heating services cover everything from furnace repair and heat pump installation to preventative maintenance, ensuring your home stays warm and cozy all winter long.
  • Breathe Easy: Improve your indoor air quality and create a healthier home environment with our air quality solutions. We install dehumidifiers to control humidity and UV light air purifiers to eliminate airborne contaminants.
  • Optimize Your Airflow: Ensure your HVAC system is running at peak efficiency with our ductwork services. We can repair leaks, address damage, and design a new ductwork system that's optimized for your Tampa home.

Our experienced technicians are skilled in all aspects of HVAC service and are dedicated to providing top-quality workmanship and customer care.

Why Choose Air Bros in Tampa?

  • Your Tampa HVAC Experts: We know Tampa! Our team understands the unique needs of homes and businesses throughout the city, from historic bungalows to modern high-rises.
  • Always On Time: We value your time and strive to provide prompt and reliable service. We offer same-day service for AC emergencies and prioritize quick response times for all your HVAC needs.
  • Skilled and Experienced: Our technicians are highly trained and experienced in all aspects of HVAC service, ensuring you receive top-quality workmanship on every job.
  • Honest and Transparent: We believe in upfront pricing with no hidden fees or surprises. You'll always know exactly what to expect.
  • Your Comfort is Our Goal: We're dedicated to ensuring your complete satisfaction with our services and your home comfort.

Contact Air Bros Today!

We're your one-stop shop for all your HVAC needs in Tampa. Whether you're facing an AC emergency, need a new heating system installed, or simply want to schedule routine maintenance, our team is here to help. Contact us today for a free consultation and let us show you why we're the trusted choice for home comfort in Tampa!

Call us at 727-217-6148 or contact us online for help in Tampa, FL.

Recent Jobs and Reviews in Tampa, FL

Job Locations and Reviews

2 Ton 15.2 SEER Heat Pump 2 stage cooling RUUD system 
~ 10 Year parts warranty  
~ 3 year Labor warranty
- paying with Card
______
- Installation of vertical air handler in attic
- New secondary safety pan (vertical unit)
- 1”filter rack
- Seal plenums to unit
- New insulated return stand
- 5 kw back up heat element
- New Wifi Thermostat
- New safety float switches
- New insulation on copper
- Strap up drain line for proper pitch
- Replace breakers as needed
- Flush and test existing condensate drain line
______
- Installation of Condenser unit on existing stands
- Flush existing refrigerant lines
- Replace breakers as needed
- New Hurricane straps 
- New UV rated insulation on copper
- New filter line dryer
- Refrigerant locking caps
- Vacuum system to 500 microns
- Charge system with refrigerant to proper pressures

- Completed to code
100% satisfaction
2 Ton 15.2 SEER Heat Pump 2 stage cooling RUUD system 
~ 10 Year parts warranty  
~ 3 year Labor warranty
- paying with Card
______
- Installation of vertical air handler in attic
- New secondary safety pan (vertical unit)
- 1”filter rack
- Seal plenums to unit
- New insulated return stand
- 5 kw back up heat element
- New Wifi Thermostat
- New safety float switches
- New insulation on copper
- Strap up drain line for proper pitch
- Replace breakers as needed
- Flush and test existing condensate drain line
______
- Installation of Condenser unit on existing stands
- Flush existing refrigerant lines
- Replace breakers as needed
- New Hurricane straps 
- New UV rated insulation on copper
- New filter line dryer
- Refrigerant locking caps
- Vacuum system to 500 microns
- Charge system with refrigerant to proper pressures

- Completed to code
100% satisfaction
Kyle K.
Kyle K. Checked in
2 Ton 15.2 SEER Heat Pump 2 stage cooling RUUD system ~ 10 Year parts warranty ~ 3 year Labor warranty - paying with Card ______ - Installation of vertical air handler in attic - New secondary safety pan (vertical unit) - 1”filter rack - Seal plenums to unit - New insulated return stand - 5 kw back up heat element - New Wifi Thermostat - New safety float switches - New insulation on copper - Strap up drain line for proper pitch - Replace breakers as needed - Flush and test existing condensate drain line ______ - Installation of Condenser unit on existing stands - Flush existing refrigerant lines - Replace breakers as needed - New Hurricane straps - New UV rated insulation on copper - New filter line dryer - Refrigerant locking caps - Vacuum system to 500 microns - Charge system with refrigerant to proper pressures - Completed to code 100% satisfaction
Tampa, FL 33629
Found system not cooling due to a bad capacitor. System is out of two year labor warranty. Replaced the capacitor at a discounted rate. System is cooling at this time with good amp draws and a 20° temperature split. Rinsed condenser coils and filled p trap in drain line with water as client vacuumed drain and did not introduce water back into the trap. 
System cooling and draining at this time.
Found system not cooling due to a bad capacitor. System is out of two year labor warranty. Replaced the capacitor at a discounted rate. System is cooling at this time with good amp draws and a 20° temperature split. Rinsed condenser coils and filled p trap in drain line with water as client vacuumed drain and did not introduce water back into the trap. 
System cooling and draining at this time.
Michael A.
Michael A. Checked in
Found system not cooling due to a bad capacitor. System is out of two year labor warranty. Replaced the capacitor at a discounted rate. System is cooling at this time with good amp draws and a 20° temperature split. Rinsed condenser coils and filled p trap in drain line with water as client vacuumed drain and did not introduce water back into the trap. System cooling and draining at this time.
Tampa, FL 33616
On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Found evaporator coil dirty with oil residue in pan. Recommend to replace evaporator coil instead of performing pull and clean. Unit draining properly.
On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Found evaporator coil dirty with oil residue in pan. Recommend to replace evaporator coil instead of performing pull and clean. Unit draining properly.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Found evaporator coil dirty with oil residue in pan. Recommend to replace evaporator coil instead of performing pull and clean. Unit draining properly.
Tampa, FL 33626
Downstairs 

Scope of work 
-pump down refrigerant 
-remove leaking txv
-weld and nylog new txv
-insulate sensing bulb 
-pressure test system 
-vacuum system 
-charge system 410a

System is currently operating within manufacture specifications
Downstairs 

Scope of work 
-pump down refrigerant 
-remove leaking txv
-weld and nylog new txv
-insulate sensing bulb 
-pressure test system 
-vacuum system 
-charge system 410a

System is currently operating within manufacture specifications
Nathan A.
Nathan A. Checked in
Downstairs Scope of work -pump down refrigerant -remove leaking txv -weld and nylog new txv -insulate sensing bulb -pressure test system -vacuum system -charge system 410a System is currently operating within manufacture specifications
Tampa, FL 33602
Need tune up on 4 systems (maint plan)
Drains and condenser coils need cleanings

Tested all safety float switches. All are functioning at this time. 
Goodman system: 2016
Movie room
Evap coils are clean
Uv light broken
 19° split
Condenser capacitor is very weak almost dead
Contactar has pitting

Trane system: foyer
2006
Replacement quote accepted

Lennox (3) 3 ton: kitchen dining 
2023
19° split
AHU in closet downstairs 
Outside looks good 
*Found loose high voltage connections. Tightened up complimentary

Lennox (4) 2 ton: master bedroom
2023
Good 
Uv light broken
Evap coils are clean
*Blower speed too low. Adjusted for proper airflow. Temp split was 27. Now 20° split. Complimentary adjustment
 

Recommendations:
4 system maintenance plan (on schedule now)
Capacitor and contactar replacement on movie room system
Replace foyer system (on schedule for Tuesday 8:30am)
Install new UV systems in all units if wanted by client.
Need tune up on 4 systems (maint plan)
Drains and condenser coils need cleanings

Tested all safety float switches. All are functioning at this time. 
Goodman system: 2016
Movie room
Evap coils are clean
Uv light broken
 19° split
Condenser capacitor is very weak almost dead
Contactar has pitting

Trane system: foyer
2006
Replacement quote accepted

Lennox (3) 3 ton: kitchen dining 
2023
19° split
AHU in closet downstairs 
Outside looks good 
*Found loose high voltage connections. Tightened up complimentary

Lennox (4) 2 ton: master bedroom
2023
Good 
Uv light broken
Evap coils are clean
*Blower speed too low. Adjusted for proper airflow. Temp split was 27. Now 20° split. Complimentary adjustment
 

Recommendations:
4 system maintenance plan (on schedule now)
Capacitor and contactar replacement on movie room system
Replace foyer system (on schedule for Tuesday 8:30am)
Install new UV systems in all units if wanted by client.
Michael A.
Michael A. Checked in
Need tune up on 4 systems (maint plan) Drains and condenser coils need cleanings Tested all safety float switches. All are functioning at this time. Goodman system: 2016 Movie room Evap coils are clean Uv light broken 19° split Condenser capacitor is very weak almost dead Contactar has pitting Trane system: foyer 2006 Replacement quote accepted Lennox (3) 3 ton: kitchen dining 2023 19° split AHU in closet downstairs Outside looks good *Found loose high voltage connections. Tightened up complimentary Lennox (4) 2 ton: master bedroom 2023 Good Uv light broken Evap coils are clean *Blower speed too low. Adjusted for proper airflow. Temp split was 27. Now 20° split. Complimentary adjustment Recommendations: 4 system maintenance plan (on schedule now) Capacitor and contactar replacement on movie room system Replace foyer system (on schedule for Tuesday 8:30am) Install new UV systems in all units if wanted by client.
Tampa, FL 33629
System #1 

Diagnostic 
-system low refrigerant indicating leak in system 

Leak very obvious at TXV inside air handler 

Called carrier to verify warranty and parts (parts on hold carrier for airbros) 

Explained that the txv is weld in and would have to recover refrigerant/pump down 

Estimate sent over 

System currently not operating properly 

Did not bill for leak search
System #1 

Diagnostic 
-system low refrigerant indicating leak in system 

Leak very obvious at TXV inside air handler 

Called carrier to verify warranty and parts (parts on hold carrier for airbros) 

Explained that the txv is weld in and would have to recover refrigerant/pump down 

Estimate sent over 

System currently not operating properly 

Did not bill for leak search
Nathan A.
Nathan A. Checked in
System #1 Diagnostic -system low refrigerant indicating leak in system Leak very obvious at TXV inside air handler Called carrier to verify warranty and parts (parts on hold carrier for airbros) Explained that the txv is weld in and would have to recover refrigerant/pump down Estimate sent over System currently not operating properly Did not bill for leak search
Tampa, FL 33602
Found downstairs system is off due to clogged drain line. 
Performed drain cleaning. Drain line may require an extensive lvl 3 treatment upon next issue with the drain backing up. 
System is 20 years old. 
Started system up and found compressor is over amping at 9.78 amps when rated for 8.7 amps. Found evaporator coils are severely rusted. 
Presented findings to client and clients would like a quote for a new system to be proactive. 
Quote sent for system replacement.
System is cooling and draining at this time.
Found downstairs system is off due to clogged drain line. 
Performed drain cleaning. Drain line may require an extensive lvl 3 treatment upon next issue with the drain backing up. 
System is 20 years old. 
Started system up and found compressor is over amping at 9.78 amps when rated for 8.7 amps. Found evaporator coils are severely rusted. 
Presented findings to client and clients would like a quote for a new system to be proactive. 
Quote sent for system replacement.
System is cooling and draining at this time.
Michael A.
Michael A. Checked in
Found downstairs system is off due to clogged drain line. Performed drain cleaning. Drain line may require an extensive lvl 3 treatment upon next issue with the drain backing up. System is 20 years old. Started system up and found compressor is over amping at 9.78 amps when rated for 8.7 amps. Found evaporator coils are severely rusted. Presented findings to client and clients would like a quote for a new system to be proactive. Quote sent for system replacement. System is cooling and draining at this time.
Tampa, FL 33616
Upon arrival, the homeowner informed me that the system had stopped working overnight. I found that the air handler was operating, but the condenser was not running. Upon further diagnosis, I found that the low-pressure safety switch was open.

I connected my gauges and found that the system was completely empty of refrigerant. I discussed the issue with the homeowner, and we agreed to perform a leak search. During the leak search, I located a refrigerant leak at a copper line joint where the joint had failed and was actively leaking refrigerant.

I discussed the repair options and cost with the homeowner, and they approved the repair. I was able to complete the copper repair the same day. After completing the repair, I pulled the system into a vacuum and verified that it was holding properly before adding the appropriate amount of refrigerant back into the system.

After completing the repair and charging the system, I tested the equipment and confirmed that it is operating properly.
Upon arrival, the homeowner informed me that the system had stopped working overnight. I found that the air handler was operating, but the condenser was not running. Upon further diagnosis, I found that the low-pressure safety switch was open.

I connected my gauges and found that the system was completely empty of refrigerant. I discussed the issue with the homeowner, and we agreed to perform a leak search. During the leak search, I located a refrigerant leak at a copper line joint where the joint had failed and was actively leaking refrigerant.

I discussed the repair options and cost with the homeowner, and they approved the repair. I was able to complete the copper repair the same day. After completing the repair, I pulled the system into a vacuum and verified that it was holding properly before adding the appropriate amount of refrigerant back into the system.

After completing the repair and charging the system, I tested the equipment and confirmed that it is operating properly.
ihsan m.
ihsan m. Checked in
Upon arrival, the homeowner informed me that the system had stopped working overnight. I found that the air handler was operating, but the condenser was not running. Upon further diagnosis, I found that the low-pressure safety switch was open. I connected my gauges and found that the system was completely empty of refrigerant. I discussed the issue with the homeowner, and we agreed to perform a leak search. During the leak search, I located a refrigerant leak at a copper line joint where the joint had failed and was actively leaking refrigerant. I discussed the repair options and cost with the homeowner, and they approved the repair. I was able to complete the copper repair the same day. After completing the repair, I pulled the system into a vacuum and verified that it was holding properly before adding the appropriate amount of refrigerant back into the system. After completing the repair and charging the system, I tested the equipment and confirmed that it is operating properly.
Tampa, FL 33647
Install new 3 ton 15 seer RUUD heat pump vertical 
Install New Air Handler
Install adjustable Stand
Install 4" Media Filter
New condensation pump 
Install New Outdoor Condenser
New Filter Drier
Install Thermostat (Auto Change over)
Thermostat Wire Included
Primary Float Safety Switch
UV Rated Outdoor Insulation
Refrigerant Locking Caps
Flush Existing Refrigerant Lines
Flush Drain Line
Vibration Pads
Hurricane Tie Down Straps
Vacuum System
Seal Supply/Return Plenums
Remove Current Equipment
Permitting
10 Year Parts Warranty
3 Year Labor Warranty
100% Satisfaction
100% property protection 

18 m 0%
Install new 3 ton 15 seer RUUD heat pump vertical 
Install New Air Handler
Install adjustable Stand
Install 4" Media Filter
New condensation pump 
Install New Outdoor Condenser
New Filter Drier
Install Thermostat (Auto Change over)
Thermostat Wire Included
Primary Float Safety Switch
UV Rated Outdoor Insulation
Refrigerant Locking Caps
Flush Existing Refrigerant Lines
Flush Drain Line
Vibration Pads
Hurricane Tie Down Straps
Vacuum System
Seal Supply/Return Plenums
Remove Current Equipment
Permitting
10 Year Parts Warranty
3 Year Labor Warranty
100% Satisfaction
100% property protection 

18 m 0%
Ricky O.
Ricky O. Checked in
Install new 3 ton 15 seer RUUD heat pump vertical Install New Air Handler Install adjustable Stand Install 4" Media Filter New condensation pump Install New Outdoor Condenser New Filter Drier Install Thermostat (Auto Change over) Thermostat Wire Included Primary Float Safety Switch UV Rated Outdoor Insulation Refrigerant Locking Caps Flush Existing Refrigerant Lines Flush Drain Line Vibration Pads Hurricane Tie Down Straps Vacuum System Seal Supply/Return Plenums Remove Current Equipment Permitting 10 Year Parts Warranty 3 Year Labor Warranty 100% Satisfaction 100% property protection 18 m 0%
Tampa, FL 33615
Replace both components they were shorted from a large power outage also found capacitor wiped out by surge. 
Unit cooling by 20 degrees
Replace both components they were shorted from a large power outage also found capacitor wiped out by surge. 
Unit cooling by 20 degrees
Corbin C.
Corbin C. Checked in
Replace both components they were shorted from a large power outage also found capacitor wiped out by surge. Unit cooling by 20 degrees
Tampa, FL 33610
First co condenser
First co pancake unit 
5 year compressor warranty
1 year parts warranty
1 year labor warranty
-Permit
-Txv kit
-Will cover drywall repair
-Clean drain
-Safety
-Seal around condenser with concrete patch
-Insulate exposed copper
-Replace breakers as needed 
-Removal and disposal of current equipment 
-Vacuum lines to 500 microns
-Start up and verify operarions
First co condenser
First co pancake unit 
5 year compressor warranty
1 year parts warranty
1 year labor warranty
-Permit
-Txv kit
-Will cover drywall repair
-Clean drain
-Safety
-Seal around condenser with concrete patch
-Insulate exposed copper
-Replace breakers as needed 
-Removal and disposal of current equipment 
-Vacuum lines to 500 microns
-Start up and verify operarions
Kyle K.
Kyle K. Checked in
First co condenser First co pancake unit 5 year compressor warranty 1 year parts warranty 1 year labor warranty -Permit -Txv kit -Will cover drywall repair -Clean drain -Safety -Seal around condenser with concrete patch -Insulate exposed copper -Replace breakers as needed -Removal and disposal of current equipment -Vacuum lines to 500 microns -Start up and verify operarions
Tampa, FL 33613
Upon arrival, the homeowner stated that the indoor blower motor was not consistently turning on. During my diagnostic, I found that the blower motor capacitor was testing below its rated capacitance, which was causing intermittent operation.

The homeowner also informed me that electrical rewiring work was recently performed on the home. During my inspection, I found that the contactor lead wires had overheated and were visibly burnt. I discussed my findings with the homeowner, and approval was given to replace the blower motor capacitor, replace the contactor, and install new lead wires to ensure safe and reliable operation.

After completing the repairs, I tested the system through a full cooling cycle. The system is now operating properly with a 19°F temperature difference between the return and supply air, which is within the normal operating range.

At this time, the system is functioning properly.

If you have any questions, please feel free to reach out. Thank you for your busin
Upon arrival, the homeowner stated that the indoor blower motor was not consistently turning on. During my diagnostic, I found that the blower motor capacitor was testing below its rated capacitance, which was causing intermittent operation.

The homeowner also informed me that electrical rewiring work was recently performed on the home. During my inspection, I found that the contactor lead wires had overheated and were visibly burnt. I discussed my findings with the homeowner, and approval was given to replace the blower motor capacitor, replace the contactor, and install new lead wires to ensure safe and reliable operation.

After completing the repairs, I tested the system through a full cooling cycle. The system is now operating properly with a 19°F temperature difference between the return and supply air, which is within the normal operating range.

At this time, the system is functioning properly.

If you have any questions, please feel free to reach out. Thank you for your busin
ihsan m.
ihsan m. Checked in
Upon arrival, the homeowner stated that the indoor blower motor was not consistently turning on. During my diagnostic, I found that the blower motor capacitor was testing below its rated capacitance, which was causing intermittent operation. The homeowner also informed me that electrical rewiring work was recently performed on the home. During my inspection, I found that the contactor lead wires had overheated and were visibly burnt. I discussed my findings with the homeowner, and approval was given to replace the blower motor capacitor, replace the contactor, and install new lead wires to ensure safe and reliable operation. After completing the repairs, I tested the system through a full cooling cycle. The system is now operating properly with a 19°F temperature difference between the return and supply air, which is within the normal operating range. At this time, the system is functioning properly. If you have any questions, please feel free to reach out. Thank you for your busin
Tampa, FL 33611
Griffin K.
Griffin K. Checked in
Install pre ran wires in panel and box install conduits from pipes to the panel and box for proper wire coverage
Tampa, FL 33602
Upon arrival, the system was not turning on, and I checked the float switch, and it was currently triggered. The pan was full of water, and the PVC pipe was clogged up. I performed a drain line treatment in a pan, cleaning, after cleaning up everything, the system turned on And with a 19° temperature difference.
Upon arrival, the system was not turning on, and I checked the float switch, and it was currently triggered. The pan was full of water, and the PVC pipe was clogged up. I performed a drain line treatment in a pan, cleaning, after cleaning up everything, the system turned on And with a 19° temperature difference.
ihsan m.
ihsan m. Checked in
Upon arrival, the system was not turning on, and I checked the float switch, and it was currently triggered. The pan was full of water, and the PVC pipe was clogged up. I performed a drain line treatment in a pan, cleaning, after cleaning up everything, the system turned on And with a 19° temperature difference.
Tampa, FL 33629
Upon arrival, I turned on the system and found that the condenser was not operating. I began my diagnostic by checking the electrical components and found a failed capacitor. I replaced the capacitor; however, the compressor still would not start.

I verified that proper high voltage was present at the compressor, but the compressor remained non-operational. To further diagnose the issue, I cooled the compressor with ice water and restarted the system. The compressor started and the system began operating temporarily, indicating the compressor is failing internally and overheating.

While the system was running, I recorded a 26°F temperature differential. I also checked the refrigerant cycle and found a subcooling reading of 22°F, which is indicative of a restricted or malfunctioning metering device (TXV).

Based on today’s diagnostic findings, I have concluded that the system has a failing compressor and a faulty TXV. I discussed these findings with the homeowner and explained that th
Upon arrival, I turned on the system and found that the condenser was not operating. I began my diagnostic by checking the electrical components and found a failed capacitor. I replaced the capacitor; however, the compressor still would not start.

I verified that proper high voltage was present at the compressor, but the compressor remained non-operational. To further diagnose the issue, I cooled the compressor with ice water and restarted the system. The compressor started and the system began operating temporarily, indicating the compressor is failing internally and overheating.

While the system was running, I recorded a 26°F temperature differential. I also checked the refrigerant cycle and found a subcooling reading of 22°F, which is indicative of a restricted or malfunctioning metering device (TXV).

Based on today’s diagnostic findings, I have concluded that the system has a failing compressor and a faulty TXV. I discussed these findings with the homeowner and explained that th
ihsan m.
ihsan m. Checked in
Upon arrival, I turned on the system and found that the condenser was not operating. I began my diagnostic by checking the electrical components and found a failed capacitor. I replaced the capacitor; however, the compressor still would not start. I verified that proper high voltage was present at the compressor, but the compressor remained non-operational. To further diagnose the issue, I cooled the compressor with ice water and restarted the system. The compressor started and the system began operating temporarily, indicating the compressor is failing internally and overheating. While the system was running, I recorded a 26°F temperature differential. I also checked the refrigerant cycle and found a subcooling reading of 22°F, which is indicative of a restricted or malfunctioning metering device (TXV). Based on today’s diagnostic findings, I have concluded that the system has a failing compressor and a faulty TXV. I discussed these findings with the homeowner and explained that th
Tampa, FL 33606
Upon arrival, I noticed water in the drain pan and the drain line that’s connected to the building was restricted. I did a nitrogen treatment in a pan cleaning, system is draining properly. If you have any questions please reach out. Thank you for your business. have a great day.
Upon arrival, I noticed water in the drain pan and the drain line that’s connected to the building was restricted. I did a nitrogen treatment in a pan cleaning, system is draining properly. If you have any questions please reach out. Thank you for your business. have a great day.
ihsan m.
ihsan m. Checked in
Upon arrival, I noticed water in the drain pan and the drain line that’s connected to the building was restricted. I did a nitrogen treatment in a pan cleaning, system is draining properly. If you have any questions please reach out. Thank you for your business. have a great day.
Tampa, FL 33607
On arrival found 2 system not cooling. 2007 r22 unit has bad blower motor. Will submit estimate for repair and replacement options.
On arrival found 2 system not cooling. 2007 r22 unit has bad blower motor. Will submit estimate for repair and replacement options.
Justin G.
Justin G. Checked in
On arrival found 2 system not cooling. 2007 r22 unit has bad blower motor. Will submit estimate for repair and replacement options.
Tampa, FL 33610
Justin G.
Justin G. Checked in
Performed maintenance on 1 system. Cleared pan and drain. Added chemical to help prevent growth. Wiped down air handler. Filter, evaporator coil, and blower clean. Temp split good. Changed batteries in thermostat. Pressures good. Electrical checked good. Unit cooling properly at this time.
Tampa, FL 33611
Replace compressor under warranty 
8 pounds of 410a
Completed repair proper operation was restored to the equipment.
Replace compressor under warranty 
8 pounds of 410a
Completed repair proper operation was restored to the equipment.
Corbin C.
Corbin C. Checked in
Replace compressor under warranty 8 pounds of 410a Completed repair proper operation was restored to the equipment.
Tampa, FL 33629
Replace damper motor reuse all other damper components
Replace damper motor reuse all other damper components
Corbin C.
Corbin C. Checked in
Replace damper motor reuse all other damper components
Tampa, FL 33606
Reason for call:
No cool 

Equipment:
Unit 1 
2022 Lennox 3 ton heat pump 
Horizontal on second floor attic 
Condenser on left side of home 
Unit 2 
2022 Lennox 3 ton heat pump 
Horizontal in garage 
Condenser in left side of home 

Summary:
Found unit 1 no cool today. Found low refrigerant charge. Found leak at compressor female joint. Compressor replacement under warranty sold for Wednesday 6-10. 
Unit 2 completed maintenance on operation within manufacturing specifications.
Reason for call:
No cool 

Equipment:
Unit 1 
2022 Lennox 3 ton heat pump 
Horizontal on second floor attic 
Condenser on left side of home 
Unit 2 
2022 Lennox 3 ton heat pump 
Horizontal in garage 
Condenser in left side of home 

Summary:
Found unit 1 no cool today. Found low refrigerant charge. Found leak at compressor female joint. Compressor replacement under warranty sold for Wednesday 6-10. 
Unit 2 completed maintenance on operation within manufacturing specifications.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Equipment: Unit 1 2022 Lennox 3 ton heat pump Horizontal on second floor attic Condenser on left side of home Unit 2 2022 Lennox 3 ton heat pump Horizontal in garage Condenser in left side of home Summary: Found unit 1 no cool today. Found low refrigerant charge. Found leak at compressor female joint. Compressor replacement under warranty sold for Wednesday 6-10. Unit 2 completed maintenance on operation within manufacturing specifications.
Tampa, FL 33629
Upon arrival, I inspected both systems. The upstairs system had a 20°F temperature differential, and the secondary system had a 19°F temperature differential, both of which are within normal operating range.

I then performed a complete electrical inspection. Both systems are operating properly with no issues or concerns at this time. The refrigerant cycles appear healthy, with no signs of leaks or restrictions.

As part of today’s maintenance, I performed a drain line treatment, condenser coil cleaning, and air handler inspection on both systems.

I also discussed the benefits of our maintenance membership program, which can help reduce long-term operating costs and keep the systems running efficiently.

If you have any questions or concerns, please don’t hesitate to reach out. Thank you for your business, and have a great day.
Upon arrival, I inspected both systems. The upstairs system had a 20°F temperature differential, and the secondary system had a 19°F temperature differential, both of which are within normal operating range.

I then performed a complete electrical inspection. Both systems are operating properly with no issues or concerns at this time. The refrigerant cycles appear healthy, with no signs of leaks or restrictions.

As part of today’s maintenance, I performed a drain line treatment, condenser coil cleaning, and air handler inspection on both systems.

I also discussed the benefits of our maintenance membership program, which can help reduce long-term operating costs and keep the systems running efficiently.

If you have any questions or concerns, please don’t hesitate to reach out. Thank you for your business, and have a great day.
ihsan m.
ihsan m. Checked in
Upon arrival, I inspected both systems. The upstairs system had a 20°F temperature differential, and the secondary system had a 19°F temperature differential, both of which are within normal operating range. I then performed a complete electrical inspection. Both systems are operating properly with no issues or concerns at this time. The refrigerant cycles appear healthy, with no signs of leaks or restrictions. As part of today’s maintenance, I performed a drain line treatment, condenser coil cleaning, and air handler inspection on both systems. I also discussed the benefits of our maintenance membership program, which can help reduce long-term operating costs and keep the systems running efficiently. If you have any questions or concerns, please don’t hesitate to reach out. Thank you for your business, and have a great day.
Tampa, FL 33611
Replace evaporator coil
Replace evaporator coil
ihsan m.
ihsan m. Checked in
Replace evaporator coil
Tampa, FL 33618
Reason for call:
No cool

Equipment:
2019 Lennox 3 ton heat pump 
Vertical on second floor in laundry room 
Condenser on left side of home 
Home has 3 split system heat pumps 

Summary:
On arrival found drain line clogged. Confirmed operation of equipment without float switch. Found equipment operating well. Found growth on blower. Installed uv treatment kit today. Flushed drain line and drain pan today. Changed all filters today.
Reason for call:
No cool

Equipment:
2019 Lennox 3 ton heat pump 
Vertical on second floor in laundry room 
Condenser on left side of home 
Home has 3 split system heat pumps 

Summary:
On arrival found drain line clogged. Confirmed operation of equipment without float switch. Found equipment operating well. Found growth on blower. Installed uv treatment kit today. Flushed drain line and drain pan today. Changed all filters today.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Equipment: 2019 Lennox 3 ton heat pump Vertical on second floor in laundry room Condenser on left side of home Home has 3 split system heat pumps Summary: On arrival found drain line clogged. Confirmed operation of equipment without float switch. Found equipment operating well. Found growth on blower. Installed uv treatment kit today. Flushed drain line and drain pan today. Changed all filters today.
Tampa, FL 33606
Upon arrival, the air handler was powered on; however, there was no airflow coming from the supply vents. I checked the blower motor and found that it was not operating. I turned off power at the thermostat and attempted to run the blower manually, but the motor still did not turn on.

Further diagnostics confirmed that proper voltage is being supplied to the motor, but the motor is non-responsive and has failed internally. The blower motor is currently burnt out. Due to the age of the system, a specific replacement motor from Carrier will need to be ordered.

Please contact the homeowner tomorrow to discuss scheduling the repair and replacement. If you have any questions, please reach out. Thank you for your business, and have a great day.
Upon arrival, the air handler was powered on; however, there was no airflow coming from the supply vents. I checked the blower motor and found that it was not operating. I turned off power at the thermostat and attempted to run the blower manually, but the motor still did not turn on.

Further diagnostics confirmed that proper voltage is being supplied to the motor, but the motor is non-responsive and has failed internally. The blower motor is currently burnt out. Due to the age of the system, a specific replacement motor from Carrier will need to be ordered.

Please contact the homeowner tomorrow to discuss scheduling the repair and replacement. If you have any questions, please reach out. Thank you for your business, and have a great day.
ihsan m.
ihsan m. Checked in
Upon arrival, the air handler was powered on; however, there was no airflow coming from the supply vents. I checked the blower motor and found that it was not operating. I turned off power at the thermostat and attempted to run the blower manually, but the motor still did not turn on. Further diagnostics confirmed that proper voltage is being supplied to the motor, but the motor is non-responsive and has failed internally. The blower motor is currently burnt out. Due to the age of the system, a specific replacement motor from Carrier will need to be ordered. Please contact the homeowner tomorrow to discuss scheduling the repair and replacement. If you have any questions, please reach out. Thank you for your business, and have a great day.
Tampa, FL 33610

Contact the Bros You Know Today!

Gravity Forms Pagination Must be Steps