Your Neighborhood HVAC Experts in Pinellas Park, FL
Pinellas Park residents can count on Air Bros Air Conditioning & Heating for all their HVAC needs. With our team of certified technicians and dedication to providing top-quality service, we ensure your home stays comfortable year-round, no matter the weather.
Call us at 727-217-6148 or contact us online for help in Pinellas Park, FL.
Your Comfort is Our Priority in Pinellas Park
Air Bros is your one-stop shop for all your home comfort needs in Pinellas Park. We offer a comprehensive range of services to keep your home comfortable and running smoothly year-round:
- Cooling & Heating: Stay comfortable no matter the weather with our complete air conditioning and heating services. We handle everything from AC repairs and installations to furnace maintenance and heat pump replacements.
- Healthy Air: Breathe easy with our indoor air quality solutions. We can install dehumidifiers to control humidity and UV light air purifiers to eliminate airborne contaminants, creating a healthier home environment for you and your family.
- Efficient Airflow: Maximize your comfort and energy savings with our professional ductwork services. We can repair or replace your ductwork to ensure optimal airflow and efficiency.
- Extended Comfort: Enjoy your pool year-round with our pool heater services. We also offer a range of electrical services, including outlet and switch replacements, ceiling fan installations, and whole-house surge protector installations.
Our experienced and certified technicians are dedicated to providing top-quality workmanship and customer care on every job.
Why Choose Air Bros in Pinellas Park?
- Local Expertise: We understand the unique climate challenges of Pinellas Park.
- Fast and Reliable Service: We offer same-day service for AC emergencies and prioritize prompt service for all your HVAC needs.
- Experienced Technicians: Our team is highly trained and experienced in all aspects of HVAC service.
- Upfront Pricing: We provide transparent pricing with no hidden costs.
- Customer Satisfaction Guaranteed: Your comfort and satisfaction are our top priorities.
Contact Air Bros Today!
Whether you need emergency AC repair, a new heating system installation, or any other HVAC service, Air Bros is here to help. Contact us today for a free consultation or to schedule a service appointment. We're proud to be your trusted HVAC partner in Pinellas Park!
Call us at 727-217-6148 or contact us online for help in Pinellas Park, FL.
Count on perfect service; Trust the bros you know!
Recent Jobs and Reviews in Pinellas Park, FL
Pinellas Park, FL at a glance
Air Bros Air Conditioning & Electrical has completed 25 jobs in Pinellas Park, FL between July 2026 and October 2026.
The most recent job was on October 7, 2026.
Air Bros Air Conditioning & Electrical has completed 52 jobs in Pinellas Park, FL in the last 12 months. The first job there was in January 2025.
Job Locations and Reviews
Ruud 3.5 ton 14.3 seer2 heat pump split system 5kw heater with pull disconnect Hurricane pad Anchor condenser WiFi thermostat Replace breakers as needed Vertical aux pan below unit in return Primary and secondary float switch Return at later date for complimentary duct sanitation ($475.00 value) Clear drain 1” filter rack for better drain pitch New top for stand if needed Remove existing equipment Connect to existing ducts and electrical Seal unit to code Tax labor and permit included 10 year parts warranty 3 year labor warranty Check or ACH payment only
On arrival found thermostat blank. Client states thermostat shut down randomly and had to be reset. Float switches clean. Thermostat gets proper power. Display on thermostat was flickering. Recommended to replace thermostat. Performed work. Connected new device to phone. Set up and tested. Pressures good. Temp split good. Filter and drain good. Unit operating properly at this time. Found insulation in bathroom. Inspected ducts and found loose grill. Tightened grill to seal. Made client aware condensate line is starting to clog causing condensate pump to run for extended period of time. Client will monitor for time being.
Home owner states unit is freezing over 2016 GOODMAN SC 3.5T System for 920sf Diagnostic -system has active refrigerant leak causing system to freeze over -air handler coils heavily damaged (look to have been scraped) Further Notes -outdoor coils impacted with debris -system is too large for home -no safety overflow on air handler (potential water damage) -no high voltage shutoff to air handler (code item) -outdoor capacitor not strapped properly -outdoor high voltage disconnect has pitting/signs of loose connection -no Hurrinace tie down straps (code item) Went over issues with home owner along with sizing of system. Offered the following services -charge system 410a (explained no guarantee on how ling refrigerant will last -replace air handler coils out of warranty -replace system with a properly sized system with permits/warranty Services declined Sending over estimates
Upon my inspection, found condenser short cycling due to bad capacitor. Outdoor fan motor was not able to come on. Replaced capacitor and started system. Found condenser coils are dirty. Client signed up for maintenance plan and we performed first maintenance today. System is cooling and draining at this time.
On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Added chemical to pan. Temp split good. Blower and evap coil had small amounts of growth. Unit is 2006 model. Made client aware to start preparing for new system in future. Unit is cooling.
Diagnostic -failed air handler blower wheel causing system to freeze over -system out of warranty (6 years second owner). Installed aftermarket 1/2hp ECM motor -cleaned blower wheel & assembly Verified system operations Further Notes -air handler coils dirty due to lack of filter changed. Recommend replacing filter System is currently operating Waived 95$ diagnostic Military discount
Upon my inspection, found one year-old system has a bad contactor due to damage from ants. Replaced contactor and recommended the client take care of the ant problem near the condenser. After starting the system, the client brought to my attention that the air handler leaks water frequently. Found that the drain line needs a cleaning and treatment. Performed a drain line cleaning and treatment. Client signed up for maintenance plan. Will return in six months to perform maintenance. Verified safety float switch inline with drain is working however it was clogged up with sludge. Cleaned float switch. System is cooling and draining at this time.
Checked full system operation. No issues found 20° split. Custom
Diagnostic -primary safety overflow switch wiring connection came loose. This caused low voltage fuse to short. Re wired safety and checked air handler connections. Found 2 other weak connections. Tightened and fixed. Replaced fuse. System is currently operating within manufacture specifications Further Notes -uv bulb is cutting in and out (bulb failing) (tested 24v coming to ballast)
Reason for call: No cool Summary: found secondary pan full of water on arrival tripping secondary float switch. Primary float was not present. Found extremely dirty filter. Found evaporator coil with debris on it. Found drain line clogged. Found sub cooling slightly low. Flushing clean drain line cleaned up secondary pan charge system with 1 pound of refrigerant. Unit is cooling by 20° draining properly Homeowners preparing for sale of home was not looking to invest a lot of money into the system today
Replace warranty compressor. 6lbs refrigerant Cleaned condenser coils. Compressor was a burn out. Treated/flushed lineset. Complimentary capacitor replacement
Replace evaporator coil, filter drier, 2lbs R410A. Unit outside of warranty. Unit cooling with 20 degree split. Unit draining properly.
Found system running upon arrival with 22° split. I checked pressures and amps no problems. Checked cap no problem. Contactor very worn but client does not want to replace right now. Wants to ride system out and only repair if absolutely necessary.
Reason for call: Member tune up Summary: Completed service to find previous hard start failed compressor failed to start up on pm. Added hard start kit and unit started to operate again. Prepared homeowner for replacement since unit is 15 years old and compressor had a hard time stating. Unit is cooling with 20 degree split.
Reason for call: No cool Summary: Found unit flooding return. Found drain clogged. Found failed primary float switch. Flushed and cleaned drain line and pan. Replace primary float switch wired to r. Operation was restored to equipment. 18 degree split. Performed 1st pm today. Schedule 6 months out. All operation of equipment is within manufacturing specifications.
Found weak capacitor replaced cap. Operation was restored to equipment 20 degree split.
Reason for call: No cool Equipment: 2018 Goodman Above the water heater Condneser on left side of home Summary: Found system critically low on charge. Charge up unit for temporary cooling possibility of refrigerant leaking out again. Found leak in Evap coil. Office will verify warranty on equipment and provide estimate for Evap coil replacement on Monday.
Reason for call: No cool Summary: Found system to have wiring outside of manufacturing diagram. Found loose wire connection on high voltage line to blower plug. Wire was energizing cabinet. Found proper spot for wire and operation was restore to equipment. Solution: For wiring outside of manufacturing diagram
Home owner states electric bill is high and unit is not cooling properly Air Handler Notes -primary safety overflow bypassed (potential water damage) -system is double filtered (4” media and 1” return) -air handler coils starting to rust -bacterial growth around supply plenum (not sealed properly) Outdoor Condenser Notes -filter drier starting to rust -coils impacted with debris (have not been thoroughly cleaned) -outdoor disconnect heavily rusted Diagnostic -system is low on refrigerant indicating leak in system System is 13 years of age and out of parts warranty. Explained potential repairs when finding leak. Also went over other issues in system Explained we can charge unit temporarily until new system goes in. Went over replacement options. Home owner would like other estimates. System is currently not operating
Diagnostic -previous contractor cut out filter drier -txv has contaminants due to no filter drier -system going into vacuum Recommend -removing contaminated refrigerant -purging refrigerant lines -install filter drier -install txv -pressure test and vacuum system -charge system 9lb 410a
Program the fans in living room Install a garage bright led
Client states drain was backing up. Found water in float switch. Cleared pan and drain. Added chemical to help prevent clogs. Blew with nitrogen. Performed maintenance on system. Found unit to have weak capacitor and worn contactor. Replaced parts. Pressures good. Temp split good. Amp draws good. Electrical checked good. Recommend to perform in place coil cleaning for evaporator coil and replace uv light. Will submit estimate. Rinsed outdoor condenser coil. Unit cooling properly at this time.
Upon arrival, I began by checking the system’s temperature split, which measured 18°F. I then inspected the electrical components and found both the compressor and blower motor operating within manufacturer specifications with no over-amping. The refrigerant cycle showed lower-than-normal pressures and reduced cooling performance. Under normal conditions, these readings could indicate a refrigerant leak; however, due to the mild outdoor temperatures, the system is not under a heavy cooling load, making the readings inconclusive. I advised the homeowner to monitor the system and contact us on a hotter day if it begins struggling to maintain the set temperature so further diagnostics can be performed under a proper load. As part of today’s maintenance, I cleaned the drain line, drain pan, condenser coil, and completed a full air handler inspection. Before leaving, I enrolled the homeowner in our maintenance membership, which includes two maintenance visits per year (every six months), f
System has an active leak. No guarantee on life span of refrigerant. Home owner would like to replace in future
Reason for call: No cool Equipment: 2012 Goodman heat pump Horizontal in garage Condneser out back Summary: On arrival system was cooling. Found water in saftey pan and switch. Found major drain debris in primary pan. Continued inspection to find weak dual capacitor and a burnt and pitted contactor. Pressure and temperatures were proper. Solution: Drain line cleaning replace capacitor replace contactor. Work completed. System is on borrowed time and would recommend preparing for replacement.