Instant Quote Shop Filters Call Air Bros

Pinellas Park, FL

air-bros-team-with-truck

Your Neighborhood HVAC Experts in Pinellas Park, FL

Pinellas Park residents can count on Air Bros Air Conditioning & Heating for all their HVAC needs. With our team of certified technicians and dedication to providing top-quality service, we ensure your home stays comfortable year-round, no matter the weather.

Call us at 727-217-6148 or contact us online for help in Pinellas Park, FL.

Your Comfort is Our Priority in Pinellas Park

Air Bros is your one-stop shop for all your home comfort needs in Pinellas Park. We offer a comprehensive range of services to keep your home comfortable and running smoothly year-round:

  • Cooling & Heating: Stay comfortable no matter the weather with our complete air conditioning and heating services. We handle everything from AC repairs and installations to furnace maintenance and heat pump replacements.
  • Healthy Air: Breathe easy with our indoor air quality solutions. We can install dehumidifiers to control humidity and UV light air purifiers to eliminate airborne contaminants, creating a healthier home environment for you and your family.
  • Efficient Airflow: Maximize your comfort and energy savings with our professional ductwork services. We can repair or replace your ductwork to ensure optimal airflow and efficiency.
  • Extended Comfort: Enjoy your pool year-round with our pool heater services. We also offer a range of electrical services, including outlet and switch replacements, ceiling fan installations, and whole-house surge protector installations.

Our experienced and certified technicians are dedicated to providing top-quality workmanship and customer care on every job.

Why Choose Air Bros in Pinellas Park?

  • Local Expertise: We understand the unique climate challenges of Pinellas Park.
  • Fast and Reliable Service: We offer same-day service for AC emergencies and prioritize prompt service for all your HVAC needs.
  • Experienced Technicians: Our team is highly trained and experienced in all aspects of HVAC service.
  • Upfront Pricing: We provide transparent pricing with no hidden costs.
  • Customer Satisfaction Guaranteed: Your comfort and satisfaction are our top priorities.

Contact Air Bros Today!

Whether you need emergency AC repair, a new heating system installation, or any other HVAC service, Air Bros is here to help. Contact us today for a free consultation or to schedule a service appointment. We're proud to be your trusted HVAC partner in Pinellas Park!

Call us at 727-217-6148 or contact us online for help in Pinellas Park, FL.

Count on perfect service; Trust the bros you know!

Recent Jobs and Reviews in Pinellas Park, FL

Pinellas Park, FL at a glance

Air Bros Air Conditioning & Electrical has completed 25 jobs in Pinellas Park, FL between March 2026 and August 2026.

The most recent job was on August 8, 2026.

Air Bros Air Conditioning & Electrical has completed 54 jobs in Pinellas Park, FL in the last 12 months. The first job there was in January 2025.

Job Locations and Reviews

Reason for call:
No cool 

Summary:
Found system to have wiring outside of manufacturing diagram. Found loose wire connection on high voltage line to blower plug. Wire was energizing cabinet.
Found proper spot for wire and operation was restore to equipment. 

Solution:
For wiring outside of manufacturing diagram
Reason for call:
No cool 

Summary:
Found system to have wiring outside of manufacturing diagram. Found loose wire connection on high voltage line to blower plug. Wire was energizing cabinet.
Found proper spot for wire and operation was restore to equipment. 

Solution:
For wiring outside of manufacturing diagram
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: Found system to have wiring outside of manufacturing diagram. Found loose wire connection on high voltage line to blower plug. Wire was energizing cabinet. Found proper spot for wire and operation was restore to equipment. Solution: For wiring outside of manufacturing diagram
Pinellas Park, FL 33782
Home owner states electric bill is high and unit is not cooling properly 

Air Handler Notes
-primary safety overflow bypassed (potential water damage)
-system is double filtered (4” media and 1” return)
-air handler coils starting to rust 
-bacterial growth around supply plenum (not sealed properly)

Outdoor Condenser Notes
-filter drier starting to rust 
-coils impacted with debris (have not been thoroughly cleaned)
-outdoor disconnect heavily rusted 

Diagnostic 
-system is low on refrigerant indicating leak in system 

System is 13 years of age and out of parts warranty. Explained potential repairs when finding leak. Also went over other issues in system 

Explained we can charge unit temporarily until new system goes in.

Went over replacement options. Home owner would like other estimates. System is currently not operating
Home owner states electric bill is high and unit is not cooling properly 

Air Handler Notes
-primary safety overflow bypassed (potential water damage)
-system is double filtered (4” media and 1” return)
-air handler coils starting to rust 
-bacterial growth around supply plenum (not sealed properly)

Outdoor Condenser Notes
-filter drier starting to rust 
-coils impacted with debris (have not been thoroughly cleaned)
-outdoor disconnect heavily rusted 

Diagnostic 
-system is low on refrigerant indicating leak in system 

System is 13 years of age and out of parts warranty. Explained potential repairs when finding leak. Also went over other issues in system 

Explained we can charge unit temporarily until new system goes in.

Went over replacement options. Home owner would like other estimates. System is currently not operating
Nathan A.
Nathan A. Checked in
Home owner states electric bill is high and unit is not cooling properly Air Handler Notes -primary safety overflow bypassed (potential water damage) -system is double filtered (4” media and 1” return) -air handler coils starting to rust -bacterial growth around supply plenum (not sealed properly) Outdoor Condenser Notes -filter drier starting to rust -coils impacted with debris (have not been thoroughly cleaned) -outdoor disconnect heavily rusted Diagnostic -system is low on refrigerant indicating leak in system System is 13 years of age and out of parts warranty. Explained potential repairs when finding leak. Also went over other issues in system Explained we can charge unit temporarily until new system goes in. Went over replacement options. Home owner would like other estimates. System is currently not operating
Pinellas Park, FL 33781
Diagnostic 
-previous contractor cut out filter drier 
-txv has contaminants due to no filter drier 
-system going into vacuum 

Recommend 
-removing contaminated refrigerant 
-purging refrigerant lines 
-install filter drier 
-install txv
-pressure test and vacuum system 
-charge system 9lb 410a
Diagnostic 
-previous contractor cut out filter drier 
-txv has contaminants due to no filter drier 
-system going into vacuum 

Recommend 
-removing contaminated refrigerant 
-purging refrigerant lines 
-install filter drier 
-install txv
-pressure test and vacuum system 
-charge system 9lb 410a
Nathan A.
Nathan A. Checked in
Diagnostic -previous contractor cut out filter drier -txv has contaminants due to no filter drier -system going into vacuum Recommend -removing contaminated refrigerant -purging refrigerant lines -install filter drier -install txv -pressure test and vacuum system -charge system 9lb 410a
Pinellas Park, FL 33781
Griffin K.
Griffin K. Checked in
Program the fans in living room Install a garage bright led
Pinellas Park, FL 33781
Client states drain was backing up. Found water in float switch. Cleared pan and drain. Added chemical to help prevent clogs. Blew with nitrogen. Performed maintenance on system. Found unit to have weak capacitor and worn contactor. Replaced parts. Pressures good. Temp split good. Amp draws good. Electrical checked good. Recommend to perform in place coil cleaning for evaporator coil and replace uv light. Will submit estimate. Rinsed outdoor condenser coil. Unit cooling properly at this time.
Client states drain was backing up. Found water in float switch. Cleared pan and drain. Added chemical to help prevent clogs. Blew with nitrogen. Performed maintenance on system. Found unit to have weak capacitor and worn contactor. Replaced parts. Pressures good. Temp split good. Amp draws good. Electrical checked good. Recommend to perform in place coil cleaning for evaporator coil and replace uv light. Will submit estimate. Rinsed outdoor condenser coil. Unit cooling properly at this time.
Justin G.
Justin G. Checked in
Client states drain was backing up. Found water in float switch. Cleared pan and drain. Added chemical to help prevent clogs. Blew with nitrogen. Performed maintenance on system. Found unit to have weak capacitor and worn contactor. Replaced parts. Pressures good. Temp split good. Amp draws good. Electrical checked good. Recommend to perform in place coil cleaning for evaporator coil and replace uv light. Will submit estimate. Rinsed outdoor condenser coil. Unit cooling properly at this time.
Pinellas Park, FL 33781
Upon arrival, I began by checking the system’s temperature split, which measured 18°F. I then inspected the electrical components and found both the compressor and blower motor operating within manufacturer specifications with no over-amping. The refrigerant cycle showed lower-than-normal pressures and reduced cooling performance. Under normal conditions, these readings could indicate a refrigerant leak; however, due to the mild outdoor temperatures, the system is not under a heavy cooling load, making the readings inconclusive. I advised the homeowner to monitor the system and contact us on a hotter day if it begins struggling to maintain the set temperature so further diagnostics can be performed under a proper load.

As part of today’s maintenance, I cleaned the drain line, drain pan, condenser coil, and completed a full air handler inspection. Before leaving, I enrolled the homeowner in our maintenance membership, which includes two maintenance visits per year (every six months), f
Upon arrival, I began by checking the system’s temperature split, which measured 18°F. I then inspected the electrical components and found both the compressor and blower motor operating within manufacturer specifications with no over-amping. The refrigerant cycle showed lower-than-normal pressures and reduced cooling performance. Under normal conditions, these readings could indicate a refrigerant leak; however, due to the mild outdoor temperatures, the system is not under a heavy cooling load, making the readings inconclusive. I advised the homeowner to monitor the system and contact us on a hotter day if it begins struggling to maintain the set temperature so further diagnostics can be performed under a proper load.

As part of today’s maintenance, I cleaned the drain line, drain pan, condenser coil, and completed a full air handler inspection. Before leaving, I enrolled the homeowner in our maintenance membership, which includes two maintenance visits per year (every six months), f
Ace m.
Ace m. Checked in
Upon arrival, I began by checking the system’s temperature split, which measured 18°F. I then inspected the electrical components and found both the compressor and blower motor operating within manufacturer specifications with no over-amping. The refrigerant cycle showed lower-than-normal pressures and reduced cooling performance. Under normal conditions, these readings could indicate a refrigerant leak; however, due to the mild outdoor temperatures, the system is not under a heavy cooling load, making the readings inconclusive. I advised the homeowner to monitor the system and contact us on a hotter day if it begins struggling to maintain the set temperature so further diagnostics can be performed under a proper load. As part of today’s maintenance, I cleaned the drain line, drain pan, condenser coil, and completed a full air handler inspection. Before leaving, I enrolled the homeowner in our maintenance membership, which includes two maintenance visits per year (every six months), f
Pinellas Park, FL 33781
System has an active leak. No guarantee on life span of refrigerant. Home owner would like to replace in future
System has an active leak. No guarantee on life span of refrigerant. Home owner would like to replace in future
Nathan A.
Nathan A. Checked in
System has an active leak. No guarantee on life span of refrigerant. Home owner would like to replace in future
Pinellas Park, FL 33781
Reason for call:
No cool

Equipment:
2012 Goodman heat pump 
Horizontal in garage 
Condneser out back 

Summary: 
On arrival system was cooling. Found water in saftey pan and switch. Found major drain debris in primary pan. Continued inspection to find weak dual capacitor and a burnt and pitted contactor. 
Pressure and temperatures were proper. 

Solution:
Drain line cleaning replace capacitor replace contactor. 
Work completed. System is on borrowed time and would recommend preparing for replacement.
Reason for call:
No cool

Equipment:
2012 Goodman heat pump 
Horizontal in garage 
Condneser out back 

Summary: 
On arrival system was cooling. Found water in saftey pan and switch. Found major drain debris in primary pan. Continued inspection to find weak dual capacitor and a burnt and pitted contactor. 
Pressure and temperatures were proper. 

Solution:
Drain line cleaning replace capacitor replace contactor. 
Work completed. System is on borrowed time and would recommend preparing for replacement.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Equipment: 2012 Goodman heat pump Horizontal in garage Condneser out back Summary: On arrival system was cooling. Found water in saftey pan and switch. Found major drain debris in primary pan. Continued inspection to find weak dual capacitor and a burnt and pitted contactor. Pressure and temperatures were proper. Solution: Drain line cleaning replace capacitor replace contactor. Work completed. System is on borrowed time and would recommend preparing for replacement.
Pinellas Park, FL 33782
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 16° temperature split at this time.
Checked system pressures and found system low on refrigerant. Client says that last company did a leak search on the equipment they installed and found no leaks. They treated the system with leak seal/UV dye. Client thinks leak is within the lineset that is burried into the foundation of the building underground. Client has issues with HOA and giving him the ability to install a new lineset through the attic. 
I offered a leak search as we cannot go based off of another companies findings but client would not like to move foward. Charged system with 2lbs of refrigerant today to bring back
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 16° temperature split at this time.
Checked system pressures and found system low on refrigerant. Client says that last company did a leak search on the equipment they installed and found no leaks. They treated the system with leak seal/UV dye. Client thinks leak is within the lineset that is burried into the foundation of the building underground. Client has issues with HOA and giving him the ability to install a new lineset through the attic. 
I offered a leak search as we cannot go based off of another companies findings but client would not like to move foward. Charged system with 2lbs of refrigerant today to bring back
Michael A.
Michael A. Checked in
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 16° temperature split at this time. Checked system pressures and found system low on refrigerant. Client says that last company did a leak search on the equipment they installed and found no leaks. They treated the system with leak seal/UV dye. Client thinks leak is within the lineset that is burried into the foundation of the building underground. Client has issues with HOA and giving him the ability to install a new lineset through the attic. I offered a leak search as we cannot go based off of another companies findings but client would not like to move foward. Charged system with 2lbs of refrigerant today to bring back
Pinellas Park, FL 33782
Ricky O.
Ricky O. Checked in
Client has bad blower motor. Gave option for repair vs replace. Client owns home with someone else and has to talk to them
Pinellas Park, FL 33781
On arrival found unit running. Client states thermostat shut off. Found unit leaking water and float switch had water in it. Cleared pan and drain. Added chemical to help prevent growth. Float tested good. Unit is a 2005 r22 in poor condition. Unit has 16* temperature split across the coil which is poor. Pressures are high and unit running hot. Found corroded contactor and weak capacitor. Made client aware of condition and will submit new system estimate.
On arrival found unit running. Client states thermostat shut off. Found unit leaking water and float switch had water in it. Cleared pan and drain. Added chemical to help prevent growth. Float tested good. Unit is a 2005 r22 in poor condition. Unit has 16* temperature split across the coil which is poor. Pressures are high and unit running hot. Found corroded contactor and weak capacitor. Made client aware of condition and will submit new system estimate.
Justin G.
Justin G. Checked in
On arrival found unit running. Client states thermostat shut off. Found unit leaking water and float switch had water in it. Cleared pan and drain. Added chemical to help prevent growth. Float tested good. Unit is a 2005 r22 in poor condition. Unit has 16* temperature split across the coil which is poor. Pressures are high and unit running hot. Found corroded contactor and weak capacitor. Made client aware of condition and will submit new system estimate.
Pinellas Park, FL 33781
Pinellas Park, FL - Found system not cooling due to clogged drain. Air handler is not accessible. Sucked and blew drain from outside best as possible. Unit is cooling properly for now
Ricky O.
Ricky O. Checked in
Found system not cooling due to clogged drain. Air handler is not accessible. Sucked and blew drain from outside best as possible. Unit is cooling properly for now
Pinellas Park, FL 33781
Justin G.
Justin G. Checked in
Units called in for service were not correct. Units 2 and 6 possibly referred to exhaust fans. Found those units operating. Recommend client to contact commercial hvac company due to communications on all units that we don’t have access to.
Pinellas Park, FL 33781
Pinellas Park, FL - Client wanted second opinion on unit. Found unit to have bad compressor. Client declined repairs from air bros at this time. Unit is not cooling.
Justin G.
Justin G. Checked in
Client wanted second opinion on unit. Found unit to have bad compressor. Client declined repairs from air bros at this time. Unit is not cooling.
Pinellas Park, FL 33781
Performed the cleaning for the blower motor in the evaporator coil
Performed the cleaning for the blower motor in the evaporator coil
Ace m.
Ace m. Checked in
Performed the cleaning for the blower motor in the evaporator coil
Pinellas Park, FL 33781
Upon arrival, I checked the temperature differential between the supply and return air and recorded an 18° split, which is within the normal operating range.

I then inspected the electrical components and found all wiring and connections to be secure and functioning properly, with no signs of shorts, burnouts, or electrical concerns. The compressor was operating within normal amperage range. However, the condenser fan motor was pulling slightly above its rated amperage.

During inspection, I found the condenser coils to be heavily impacted with dirt and debris, restricting airflow and causing the system to work harder than normal. I performed a water-based condenser coil cleaning and drain line treatment. The cleaning improved airflow and system performance, but the condenser would still benefit from a more advanced deep cleaning moving forward.

At the air handler, I inspected the evaporator coil and found it to be slightly dirty as well. Overall, the air handler is currently operati
Upon arrival, I checked the temperature differential between the supply and return air and recorded an 18° split, which is within the normal operating range.

I then inspected the electrical components and found all wiring and connections to be secure and functioning properly, with no signs of shorts, burnouts, or electrical concerns. The compressor was operating within normal amperage range. However, the condenser fan motor was pulling slightly above its rated amperage.

During inspection, I found the condenser coils to be heavily impacted with dirt and debris, restricting airflow and causing the system to work harder than normal. I performed a water-based condenser coil cleaning and drain line treatment. The cleaning improved airflow and system performance, but the condenser would still benefit from a more advanced deep cleaning moving forward.

At the air handler, I inspected the evaporator coil and found it to be slightly dirty as well. Overall, the air handler is currently operati
Ace m.
Ace m. Checked in
Upon arrival, I checked the temperature differential between the supply and return air and recorded an 18° split, which is within the normal operating range. I then inspected the electrical components and found all wiring and connections to be secure and functioning properly, with no signs of shorts, burnouts, or electrical concerns. The compressor was operating within normal amperage range. However, the condenser fan motor was pulling slightly above its rated amperage. During inspection, I found the condenser coils to be heavily impacted with dirt and debris, restricting airflow and causing the system to work harder than normal. I performed a water-based condenser coil cleaning and drain line treatment. The cleaning improved airflow and system performance, but the condenser would still benefit from a more advanced deep cleaning moving forward. At the air handler, I inspected the evaporator coil and found it to be slightly dirty as well. Overall, the air handler is currently operati
Pinellas Park, FL 33781
Charge system back to factory specifications
Charge system back to factory specifications
Nathan A.
Nathan A. Checked in
Charge system back to factory specifications
Pinellas Park, FL 33782
On arrival found unit leaking water due to impacted evap coil. Pulled and cleaned coil. Wiped down air handler. Replaced weak capacitor. Filled unit back to factory specs. Performed maintenance on system. Unit cooling properly  at this time .
On arrival found unit leaking water due to impacted evap coil. Pulled and cleaned coil. Wiped down air handler. Replaced weak capacitor. Filled unit back to factory specs. Performed maintenance on system. Unit cooling properly  at this time .
Justin G.
Justin G. Checked in
On arrival found unit leaking water due to impacted evap coil. Pulled and cleaned coil. Wiped down air handler. Replaced weak capacitor. Filled unit back to factory specs. Performed maintenance on system. Unit cooling properly at this time .
Pinellas Park, FL 33781
Justin G.
Justin G. Checked in
Replaced warranty evap coil and horizontal pan. Added primary float switch. Replaced filter dryer. Pulled vacuum below 500 microns. Start and test. Added refrigerant back to factory specs. Unit cooling and draining at this time.
Pinellas Park, FL 33781
Full System Tuneup 

System is operating within manufacture specifications 

Notes 
-indoor system 2019
-outdoor system 2009
-outdoor coils heavily corroded 
-outdoor fan motor pulling higher amps 
-outdoor disconnect rusting and not secured to wall
Full System Tuneup 

System is operating within manufacture specifications 

Notes 
-indoor system 2019
-outdoor system 2009
-outdoor coils heavily corroded 
-outdoor fan motor pulling higher amps 
-outdoor disconnect rusting and not secured to wall
Nathan A.
Nathan A. Checked in
Full System Tuneup System is operating within manufacture specifications Notes -indoor system 2019 -outdoor system 2009 -outdoor coils heavily corroded -outdoor fan motor pulling higher amps -outdoor disconnect rusting and not secured to wall
Pinellas Park, FL 33781
Full system tuneup 

Wiped Down Air Handler 

Checked temperature splits 

Tested Safety Overflow Switch 

Inspected Air Handler Coils 

Inspected Blower Wheel & Assembly 

Checked cap mfd 

Checked contactor 

Inspected wiring/Tightened Connections 

Compressor amps 

Motor amps 

Cleaned Service Panel

Cleared drain line and pan 

Added pan tab to help with buildup 

Checked blower amps 

Checked filter 

Thermostat operations 

Checked cooling 

Unit is operating at this time 

Notes
-blower wheel & assembly have construction debris buildup (recommend removing & sanitizing)
-outdoor suction line insulation breaking down 
-outdoor defrost board has heat exhaustion across terminals 

Will call manufacture to verify any warranties 

System is operating and in good standing
Full system tuneup 

Wiped Down Air Handler 

Checked temperature splits 

Tested Safety Overflow Switch 

Inspected Air Handler Coils 

Inspected Blower Wheel & Assembly 

Checked cap mfd 

Checked contactor 

Inspected wiring/Tightened Connections 

Compressor amps 

Motor amps 

Cleaned Service Panel

Cleared drain line and pan 

Added pan tab to help with buildup 

Checked blower amps 

Checked filter 

Thermostat operations 

Checked cooling 

Unit is operating at this time 

Notes
-blower wheel & assembly have construction debris buildup (recommend removing & sanitizing)
-outdoor suction line insulation breaking down 
-outdoor defrost board has heat exhaustion across terminals 

Will call manufacture to verify any warranties 

System is operating and in good standing
Nathan A.
Nathan A. Checked in
Full system tuneup Wiped Down Air Handler Checked temperature splits Tested Safety Overflow Switch Inspected Air Handler Coils Inspected Blower Wheel & Assembly Checked cap mfd Checked contactor Inspected wiring/Tightened Connections Compressor amps Motor amps Cleaned Service Panel Cleared drain line and pan Added pan tab to help with buildup Checked blower amps Checked filter Thermostat operations Checked cooling Unit is operating at this time Notes -blower wheel & assembly have construction debris buildup (recommend removing & sanitizing) -outdoor suction line insulation breaking down -outdoor defrost board has heat exhaustion across terminals Will call manufacture to verify any warranties System is operating and in good standing
Pinellas Park, FL 33781
Full system tuneup 

Wiped Down Air Handler 

Checked temperature splits (15° split) (unit will need 1lb 410a for 20° design split)

Inspected Air Handler Coils 

Inspected Blower Wheel & Assembly (bacterial growth accumulating)

Checked cap mfd (10% threshold) (herm side reading 42.7) (capacitor starting to rust)

Checked contactor 

Inspected wiring 

Compressor amps 

Motor amps 

Cleaned condenser coils 

Cleared drain line and pan 

Added pan tab to help with buildup 

Checked blower amps 

Checked filter (home owner just replaced) (2 ceiling returns)

Thermostat operations 

Checked cooling 

Unit is operating at this time
Full system tuneup 

Wiped Down Air Handler 

Checked temperature splits (15° split) (unit will need 1lb 410a for 20° design split)

Inspected Air Handler Coils 

Inspected Blower Wheel & Assembly (bacterial growth accumulating)

Checked cap mfd (10% threshold) (herm side reading 42.7) (capacitor starting to rust)

Checked contactor 

Inspected wiring 

Compressor amps 

Motor amps 

Cleaned condenser coils 

Cleared drain line and pan 

Added pan tab to help with buildup 

Checked blower amps 

Checked filter (home owner just replaced) (2 ceiling returns)

Thermostat operations 

Checked cooling 

Unit is operating at this time
Nathan A.
Nathan A. Checked in
Full system tuneup Wiped Down Air Handler Checked temperature splits (15° split) (unit will need 1lb 410a for 20° design split) Inspected Air Handler Coils Inspected Blower Wheel & Assembly (bacterial growth accumulating) Checked cap mfd (10% threshold) (herm side reading 42.7) (capacitor starting to rust) Checked contactor Inspected wiring Compressor amps Motor amps Cleaned condenser coils Cleared drain line and pan Added pan tab to help with buildup Checked blower amps Checked filter (home owner just replaced) (2 ceiling returns) Thermostat operations Checked cooling Unit is operating at this time
Pinellas Park, FL 33782
3 ton Ruud 18 seer invertor 
Heat pump
10 year parts warranty
3 year labor warranty
18 months 0% financing avail 
Qualifies for 1,000$ Duke rebate
-Hurricane pad
-Permit
-Hurricane tiedowns
-UV rated armorflex
-Replace breakers as needed
-Adjustable air handler stand
-4” filter
-Heat w breaker 
-Condensate pump
-Safeties
-Thermostat
-New drain line w clean out
3 ton Ruud 18 seer invertor 
Heat pump
10 year parts warranty
3 year labor warranty
18 months 0% financing avail 
Qualifies for 1,000$ Duke rebate
-Hurricane pad
-Permit
-Hurricane tiedowns
-UV rated armorflex
-Replace breakers as needed
-Adjustable air handler stand
-4” filter
-Heat w breaker 
-Condensate pump
-Safeties
-Thermostat
-New drain line w clean out
Kyle K.
Kyle K. Checked in
3 ton Ruud 18 seer invertor Heat pump 10 year parts warranty 3 year labor warranty 18 months 0% financing avail Qualifies for 1,000$ Duke rebate -Hurricane pad -Permit -Hurricane tiedowns -UV rated armorflex -Replace breakers as needed -Adjustable air handler stand -4” filter -Heat w breaker -Condensate pump -Safeties -Thermostat -New drain line w clean out
Pinellas Park, FL 33781
Replace 125 amp federal pacific panel
Label and remove existing wires from panel 
Remove panel 
Install new connectors on the 1 1/4in pvc feeding panel 
Install new 125 amp main lug panel 
Reinstall pre label wires into panel 
Install new whole home surge protector 
Drywall will need to be cut to install new panel 

***Air bros is not responsible for drywall repairs as well 
Air bros is not responsible for the main breaker does not function properly
Replace 125 amp federal pacific panel
Label and remove existing wires from panel 
Remove panel 
Install new connectors on the 1 1/4in pvc feeding panel 
Install new 125 amp main lug panel 
Reinstall pre label wires into panel 
Install new whole home surge protector 
Drywall will need to be cut to install new panel 

***Air bros is not responsible for drywall repairs as well 
Air bros is not responsible for the main breaker does not function properly
Griffin K.
Griffin K. Checked in
Replace 125 amp federal pacific panel Label and remove existing wires from panel Remove panel Install new connectors on the 1 1/4in pvc feeding panel Install new 125 amp main lug panel Reinstall pre label wires into panel Install new whole home surge protector Drywall will need to be cut to install new panel ***Air bros is not responsible for drywall repairs as well Air bros is not responsible for the main breaker does not function properly
Pinellas Park, FL 33781
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is not within factory range. Replaced capacitor under parts warranty. Inspected Contactar. Made sure all connections are tight. System is cooling with an 18° temperature split at this time.
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is not within factory range. Replaced capacitor under parts warranty. Inspected Contactar. Made sure all connections are tight. System is cooling with an 18° temperature split at this time.
Michael A.
Michael A. Checked in
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is not within factory range. Replaced capacitor under parts warranty. Inspected Contactar. Made sure all connections are tight. System is cooling with an 18° temperature split at this time.