Instant Quote Shop Filters Call Air Bros Book Service

St. Petersburg, FL

air-bros-team-with-truck

The Best AC Repair in St. Petersburg, FL — From Technicians Your Neighbors Already Trust

When your AC quits in the middle of a St. Pete summer, you don't want a stranger in an unmarked van. You want a technician your neighbors already know and trust. Air Bros Air Conditioning & Electrical has been fixing air conditioners in St. Petersburg since 2020, but our roots run deeper — founder Ricky Orta grew up learning the trade from his father and has been a licensed HVAC contractor since 2006. That local, hands-on experience is why homeowners from Historic Kenwood to Snell Isle call us the best AC repair company in St. Petersburg.

We're headquartered right here in the Shore Acres neighborhood, so when you call, you're not routed to a call center — you're talking to the same local team that services your street.

Call us at 727-217-6148 or contact us online today for all of your HVAC, indoor air quality and electrical needs.

Meet the technicians who service St. Petersburg

What to expect when we show up

Calling a repair company you've never used before shouldn't feel like a gamble. Here's exactly how an Air Bros service call goes, every time.

You'll get a heads-up before we arrive, then a uniformed technician in a marked Air Bros vehicle shows up in the window we promised. We diagnose the whole system — not just the obvious symptom — then explain what we found and what your options are before any work starts. You approve the price up front, we make the repair, and we don't leave until we've confirmed the system is cooling the way it should.

Every technician is a background-checked, drug-tested Air Bros employee — never a subcontractor — and each one is trained to service every major AC and heat pump brand. It's the kind of consistency you can only get from a local team that answers to its own name.

And if something isn't right? Our 100% satisfaction guarantee means we make it right.

Signs you need AC repair

St. Petersburg's heat and humidity push air conditioners harder than almost anywhere else in the country. Call for AC repair if you notice:

  • Warm air blowing from vents, or the system running constantly without cooling
  • Water pooling around your air handler (a common issue in St. Pete's older homes with attic-run drain lines)
  • Musty odors or visible mold near vents — a sign of a clogged condensate line or dirty coil
  • Rising humidity indoors despite the AC running
  • Short cycling, tripped breakers, or a system that won't turn on at all

Our technicians diagnose the full system on every call — refrigerant charge, temperature split, electrical connections, and drain line — so you get a real fix, not a temporary patch.

Comprehensive HVAC Services in St. Petersburg

We offer a full range of heating and cooling services to keep your St. Petersburg, FL, home comfortable year-round:

  • Air Conditioning: From AC repair and AC installation to routine maintenance, we ensure your cooling system keeps you comfortable during those hot Florida summers. We offer same-day service for AC emergencies, so you never have to suffer in the heat.
  • Heating: Stay warm and cozy in the winter with our comprehensive heating services. We repair and install all types of heating systems, including furnaces and heat pumps, and offer preventative maintenance to keep your system running efficiently.
  • Indoor Air Quality: Improve your indoor air quality with our dehumidifier and UV light installation services. We'll help you control excess humidity and eliminate airborne contaminants, creating a healthier home environment.
  • Ductwork: Ensure optimal airflow and energy efficiency with our ductwork repair and installation services. We can address leaks and damage, and design a system that's perfect for your home.
  • Pool Heater Services: Extend your swim season with our pool heater installation and repair services.
  • Electrical Services: From outlet and switch replacements to ceiling fan installations to whole-house surge protector installations, we have the experts to handle your electrical service needs.

Our experienced technicians are skilled in all aspects of HVAC service and are dedicated to providing top-quality workmanship and customer care.

Why Choose Air Bros?

  • Local Expertise: We understand the unique climate challenges of St. Petersburg.
  • Fast and Reliable Service: We offer same-day service for AC emergencies and prioritize prompt service for all your HVAC needs.
  • Experienced Technicians: Our team is highly trained and experienced in all aspects of HVAC service.
  • Upfront Pricing: We provide transparent pricing with no hidden costs.
  • Customer Satisfaction Guaranteed: Your comfort and satisfaction are our top priorities.

Contact Air Bros Today!

Whether you need emergency AC repair, a new heating system installation, or any other HVAC service, Air Bros is here to help. Contact us today for a free consultation or to schedule a service appointment. We're proud to be your trusted HVAC partner in St. Petersburg!

Call us at 727-217-6148 or contact us online today!

Recent Jobs and Reviews in St. Petersburg, FL

Job Locations and Reviews

New Construction 

New System 2025

Air handler error code indicating refrigerant sensor failed. Home owner will have contractor fix issue under warranty.
New Construction 

New System 2025

Air handler error code indicating refrigerant sensor failed. Home owner will have contractor fix issue under warranty.
Nathan A.
Nathan A. Checked in
New Construction New System 2025 Air handler error code indicating refrigerant sensor failed. Home owner will have contractor fix issue under warranty.
St. Petersburg, FL 33711
Client Concerns 
-Home is not cooling below 78° 
-Black particles coming out of vents 

1875sf Home With 3.5T System 

Outdoor System Notes 
-Condneser does not meet clearance to home wall. Outdoor system notes breathing properly allowing unit to disperse air 

Air Handler Notes 
-return (wood coffin box) not sealed properly. This is causing unit to remove garage air and pass through system. Integrity of coffin box very poor 
-Bacterial growth on blower wheel/assembly (passing through ductwork)
-No primary safety switch (potential water damage)

System has a 20° temperature split indicating it is cooling 

Attic Notes 
-ductwork has patches and holes 
-ductwork collapsed in some areas 
-ductwork not sized/balanced properly 
-ductwork pinched in some areas 
-attic insulation very low 

Recommend 
-replace ducting and blanching properly 
-adding insulation to home 
-install primary safety overflow switch 
-remove/sanitize blower wheel 

Outdoor system potentially flooded (unit is also on
Client Concerns 
-Home is not cooling below 78° 
-Black particles coming out of vents 

1875sf Home With 3.5T System 

Outdoor System Notes 
-Condneser does not meet clearance to home wall. Outdoor system notes breathing properly allowing unit to disperse air 

Air Handler Notes 
-return (wood coffin box) not sealed properly. This is causing unit to remove garage air and pass through system. Integrity of coffin box very poor 
-Bacterial growth on blower wheel/assembly (passing through ductwork)
-No primary safety switch (potential water damage)

System has a 20° temperature split indicating it is cooling 

Attic Notes 
-ductwork has patches and holes 
-ductwork collapsed in some areas 
-ductwork not sized/balanced properly 
-ductwork pinched in some areas 
-attic insulation very low 

Recommend 
-replace ducting and blanching properly 
-adding insulation to home 
-install primary safety overflow switch 
-remove/sanitize blower wheel 

Outdoor system potentially flooded (unit is also on
Nathan A.
Nathan A. Checked in
Client Concerns -Home is not cooling below 78° -Black particles coming out of vents 1875sf Home With 3.5T System Outdoor System Notes -Condneser does not meet clearance to home wall. Outdoor system notes breathing properly allowing unit to disperse air Air Handler Notes -return (wood coffin box) not sealed properly. This is causing unit to remove garage air and pass through system. Integrity of coffin box very poor -Bacterial growth on blower wheel/assembly (passing through ductwork) -No primary safety switch (potential water damage) System has a 20° temperature split indicating it is cooling Attic Notes -ductwork has patches and holes -ductwork collapsed in some areas -ductwork not sized/balanced properly -ductwork pinched in some areas -attic insulation very low Recommend -replace ducting and blanching properly -adding insulation to home -install primary safety overflow switch -remove/sanitize blower wheel Outdoor system potentially flooded (unit is also on
St. Petersburg, FL 33704
Downstairs Trane System Diagnostic 
-drain line backed up causing safety to shut off system 

Scope of work 
-cleared drain line 
-cleared drain pan and canals 
-added pan tablets to help with future buildup 
-primed drain & trap 

System is currently draining and operating within manufacture specifications
Downstairs Trane System Diagnostic 
-drain line backed up causing safety to shut off system 

Scope of work 
-cleared drain line 
-cleared drain pan and canals 
-added pan tablets to help with future buildup 
-primed drain & trap 

System is currently draining and operating within manufacture specifications
Nathan A.
Nathan A. Checked in
Downstairs Trane System Diagnostic -drain line backed up causing safety to shut off system Scope of work -cleared drain line -cleared drain pan and canals -added pan tablets to help with future buildup -primed drain & trap System is currently draining and operating within manufacture specifications
St. Petersburg, FL 33704
Upon arrival home owner states unit is coming back on and needed to cancel call. Explained unit turning off and on intermittently is not normal. Home owner allowed me to come into home for a quick check. 

Found water in safety indicating drain line backing up. Home owner asked if I could clear drain. 

Cleared drain line and drain pan 

Added pan solution to help with buildup 

Verified system is cooling and draining
Upon arrival home owner states unit is coming back on and needed to cancel call. Explained unit turning off and on intermittently is not normal. Home owner allowed me to come into home for a quick check. 

Found water in safety indicating drain line backing up. Home owner asked if I could clear drain. 

Cleared drain line and drain pan 

Added pan solution to help with buildup 

Verified system is cooling and draining
Nathan A.
Nathan A. Checked in
Upon arrival home owner states unit is coming back on and needed to cancel call. Explained unit turning off and on intermittently is not normal. Home owner allowed me to come into home for a quick check. Found water in safety indicating drain line backing up. Home owner asked if I could clear drain. Cleared drain line and drain pan Added pan solution to help with buildup Verified system is cooling and draining
St. Petersburg, FL 33713
Home shared video of outdoor unit short cycling. 

2.5T Goodman AH and Ameristar Outdoor 

Diagnostic 
-drain line backing up causing system to short cycle 

Cleared drain line and system began to run 

Found system 1lb low on 410a

Explained to home owner system has a potential leak. Went over leak search option.


Home owner would like to charge system and monitor 

Charged system back to factory specifications 

Recommend 
-leak search in future 
-maintenance on system (coils impacted)
-keeping up with filter (ah coils accumulating hair)
Home shared video of outdoor unit short cycling. 

2.5T Goodman AH and Ameristar Outdoor 

Diagnostic 
-drain line backing up causing system to short cycle 

Cleared drain line and system began to run 

Found system 1lb low on 410a

Explained to home owner system has a potential leak. Went over leak search option.


Home owner would like to charge system and monitor 

Charged system back to factory specifications 

Recommend 
-leak search in future 
-maintenance on system (coils impacted)
-keeping up with filter (ah coils accumulating hair)
Nathan A.
Nathan A. Checked in
Home shared video of outdoor unit short cycling. 2.5T Goodman AH and Ameristar Outdoor Diagnostic -drain line backing up causing system to short cycle Cleared drain line and system began to run Found system 1lb low on 410a Explained to home owner system has a potential leak. Went over leak search option. Home owner would like to charge system and monitor Charged system back to factory specifications Recommend -leak search in future -maintenance on system (coils impacted) -keeping up with filter (ah coils accumulating hair)
St. Petersburg, FL 33710
Odor complaint:
Found large gap on supply plenum in the attic allowing attic air to enter the system. 
Performed a lvl 2 duct seal repair to this affected area. 

Let client know their duct work is very old and insulation is poor around the metal ducts in some areas. 
Client is aware of duct system and interested in replacing duct work on the future. Will provide quote when client is ready.
Odor complaint:
Found large gap on supply plenum in the attic allowing attic air to enter the system. 
Performed a lvl 2 duct seal repair to this affected area. 

Let client know their duct work is very old and insulation is poor around the metal ducts in some areas. 
Client is aware of duct system and interested in replacing duct work on the future. Will provide quote when client is ready.
Michael A.
Michael A. Checked in
Odor complaint: Found large gap on supply plenum in the attic allowing attic air to enter the system. Performed a lvl 2 duct seal repair to this affected area. Let client know their duct work is very old and insulation is poor around the metal ducts in some areas. Client is aware of duct system and interested in replacing duct work on the future. Will provide quote when client is ready.
St. Petersburg, FL 33710
Reason for call:
No cool 

Summary:
On arrival found compressor not turning on. Found a failed capacitor on the compressor side. 
Replaced capacitor and contactor. 
This restored operation to equipment. 
Unit is cooling with a 18 degree split. 
Unit is draining properly. 
Homeowner signed up on maintenance contract. 
Service will be performed in 6 Mon.
Reason for call:
No cool 

Summary:
On arrival found compressor not turning on. Found a failed capacitor on the compressor side. 
Replaced capacitor and contactor. 
This restored operation to equipment. 
Unit is cooling with a 18 degree split. 
Unit is draining properly. 
Homeowner signed up on maintenance contract. 
Service will be performed in 6 Mon.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: On arrival found compressor not turning on. Found a failed capacitor on the compressor side. Replaced capacitor and contactor. This restored operation to equipment. Unit is cooling with a 18 degree split. Unit is draining properly. Homeowner signed up on maintenance contract. Service will be performed in 6 Mon.
St. Petersburg, FL 33702
Run a new dedicated circuit from main panel to the water heater on exterior of home 
Install a disconnect 
Run conduit on exterior set junction boxes as needed
Run a new dedicated circuit from main panel to the water heater on exterior of home 
Install a disconnect 
Run conduit on exterior set junction boxes as needed
Griffin K.
Griffin K. Checked in
Run a new dedicated circuit from main panel to the water heater on exterior of home Install a disconnect Run conduit on exterior set junction boxes as needed
St. Petersburg, FL 33702
Reason for call:
Precision tune up 

Summary:
Performed pm to find operation of equipment within manufacturing specifications. Confirmed proper temperature split and amp draws. Condenser has surge protection installed. Ahu had uv treatment kit installed. Sold uv bulb replacement to be installed on first maintenance visit flush drain line and both coils.
Reason for call:
Precision tune up 

Summary:
Performed pm to find operation of equipment within manufacturing specifications. Confirmed proper temperature split and amp draws. Condenser has surge protection installed. Ahu had uv treatment kit installed. Sold uv bulb replacement to be installed on first maintenance visit flush drain line and both coils.
Corbin C.
Corbin C. Checked in
Reason for call: Precision tune up Summary: Performed pm to find operation of equipment within manufacturing specifications. Confirmed proper temperature split and amp draws. Condenser has surge protection installed. Ahu had uv treatment kit installed. Sold uv bulb replacement to be installed on first maintenance visit flush drain line and both coils.
St. Petersburg, FL 33701
Ruud 2.5 ton Heat pump
15 seer two stage
10 year parts warranty
3 year labor warranty
18months 0% financing
«Hurricane tiedowns
-UV rated armorflex
-Flush drain line
-Vacuum refrigerant lines under 500 microns
-Replace breakers as needed
-Adjustable metal air handler stand
-1" filter rack with filter
-Replace exposed armorflex
-Cleanout tee for drain line
-Wifi thermostat Honeywell
-100% satisfaction guarantee
Ruud 2.5 ton Heat pump
15 seer two stage
10 year parts warranty
3 year labor warranty
18months 0% financing
«Hurricane tiedowns
-UV rated armorflex
-Flush drain line
-Vacuum refrigerant lines under 500 microns
-Replace breakers as needed
-Adjustable metal air handler stand
-1" filter rack with filter
-Replace exposed armorflex
-Cleanout tee for drain line
-Wifi thermostat Honeywell
-100% satisfaction guarantee
Martin W.
Martin W. Checked in
Ruud 2.5 ton Heat pump 15 seer two stage 10 year parts warranty 3 year labor warranty 18months 0% financing «Hurricane tiedowns -UV rated armorflex -Flush drain line -Vacuum refrigerant lines under 500 microns -Replace breakers as needed -Adjustable metal air handler stand -1" filter rack with filter -Replace exposed armorflex -Cleanout tee for drain line -Wifi thermostat Honeywell -100% satisfaction guarantee
St. Petersburg, FL 33708
Performed Maitenence in both systems. Bedroom system required a lvl 1 drain cleaning and treatment beyond a basic Maitenence. 
Drain lines and pans are clean and treated. 
Both systems are cooling at this time. 
Bedroom system secondary pan is tied into the drain line which is allowing water to back feed. If this becomes an issue in the future, we will need to reconfigure the set up. 
No apparent issues at this time after cleanings.
Performed Maitenence in both systems. Bedroom system required a lvl 1 drain cleaning and treatment beyond a basic Maitenence. 
Drain lines and pans are clean and treated. 
Both systems are cooling at this time. 
Bedroom system secondary pan is tied into the drain line which is allowing water to back feed. If this becomes an issue in the future, we will need to reconfigure the set up. 
No apparent issues at this time after cleanings.
Michael A.
Michael A. Checked in
Performed Maitenence in both systems. Bedroom system required a lvl 1 drain cleaning and treatment beyond a basic Maitenence. Drain lines and pans are clean and treated. Both systems are cooling at this time. Bedroom system secondary pan is tied into the drain line which is allowing water to back feed. If this becomes an issue in the future, we will need to reconfigure the set up. No apparent issues at this time after cleanings.
St. Petersburg, FL 33701
Reason for call:
water leak 

Summary:
Found unit above kitchen with a clogged drain. Water got into plenum and was leaking from there. Flushed drain line to restore operation to equipment and drainage system. Got all water out of pan, unit, and ceiling panels. Confirm unit had a 20 degree temperature split. Left fan on informed manager to leave fan on for 3 days.
Reason for call:
water leak 

Summary:
Found unit above kitchen with a clogged drain. Water got into plenum and was leaking from there. Flushed drain line to restore operation to equipment and drainage system. Got all water out of pan, unit, and ceiling panels. Confirm unit had a 20 degree temperature split. Left fan on informed manager to leave fan on for 3 days.
Corbin C.
Corbin C. Checked in
Reason for call: water leak Summary: Found unit above kitchen with a clogged drain. Water got into plenum and was leaking from there. Flushed drain line to restore operation to equipment and drainage system. Got all water out of pan, unit, and ceiling panels. Confirm unit had a 20 degree temperature split. Left fan on informed manager to leave fan on for 3 days.
St. Petersburg, FL 33713
The TXV is restricted, the system is under warranty. We can get the part from manufacturer, but the homeowner is responsible for labor. Also, the capacitor is completely empty and I replaced it for the homeowner at a discounted price.
The TXV is restricted, the system is under warranty. We can get the part from manufacturer, but the homeowner is responsible for labor. Also, the capacitor is completely empty and I replaced it for the homeowner at a discounted price.
ihsan m.
ihsan m. Checked in
The TXV is restricted, the system is under warranty. We can get the part from manufacturer, but the homeowner is responsible for labor. Also, the capacitor is completely empty and I replaced it for the homeowner at a discounted price.
St. Petersburg, FL 33705
Reason for call:
No cool 

Summary:
Found failed capacitor and outdated contactor. 

Operation was restored to equipment unit cooling by 20 degrees 

Unit needs filter installed 22x20x1 

Solution:
Replace cap and contactor 1 year parts and labor warranty
Reason for call:
No cool 

Summary:
Found failed capacitor and outdated contactor. 

Operation was restored to equipment unit cooling by 20 degrees 

Unit needs filter installed 22x20x1 

Solution:
Replace cap and contactor 1 year parts and labor warranty
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: Found failed capacitor and outdated contactor. Operation was restored to equipment unit cooling by 20 degrees Unit needs filter installed 22x20x1 Solution: Replace cap and contactor 1 year parts and labor warranty
St. Petersburg, FL 33712
On arrival found unit freezing up. Made client aware coil was dirty and below factory specs on refrigerant m. Cleaned coil in place. Added refrigerant. Unit cooling and draining properly. Made client aware to monitor unit. If unit freezes again due to low refrigerant, we will need to perform leak search to determine cause.
On arrival found unit freezing up. Made client aware coil was dirty and below factory specs on refrigerant m. Cleaned coil in place. Added refrigerant. Unit cooling and draining properly. Made client aware to monitor unit. If unit freezes again due to low refrigerant, we will need to perform leak search to determine cause.
Justin G.
Justin G. Checked in
On arrival found unit freezing up. Made client aware coil was dirty and below factory specs on refrigerant m. Cleaned coil in place. Added refrigerant. Unit cooling and draining properly. Made client aware to monitor unit. If unit freezes again due to low refrigerant, we will need to perform leak search to determine cause.
St. Petersburg, FL 33711
Install new attic gable vent fan and tie into existing electrical
Install new attic gable vent fan and tie into existing electrical
Griffin K.
Griffin K. Checked in
Install new attic gable vent fan and tie into existing electrical
St. Petersburg, FL 33705
Reason for call:
Humidity concerns

Summary:
Found unit operating well. Changed two setting in thermostat to help with dehumidification from the equipment. Recommended a low set point homeowner was ok with 74 degrees. 

Found sofets were painted over and causing a lack of airflow in the attic. Gable fan is install and operating. Two gable vents are present. 
Replacing the sofets will improve airflow in attic lowing attic humidity. 

Attic are is also leaking into home in many spots. Recommended trying the sofets and thermostat changes first. But if the issue persists they should look into air sealing of the attic.
Reason for call:
Humidity concerns

Summary:
Found unit operating well. Changed two setting in thermostat to help with dehumidification from the equipment. Recommended a low set point homeowner was ok with 74 degrees. 

Found sofets were painted over and causing a lack of airflow in the attic. Gable fan is install and operating. Two gable vents are present. 
Replacing the sofets will improve airflow in attic lowing attic humidity. 

Attic are is also leaking into home in many spots. Recommended trying the sofets and thermostat changes first. But if the issue persists they should look into air sealing of the attic.
Corbin C.
Corbin C. Checked in
Reason for call: Humidity concerns Summary: Found unit operating well. Changed two setting in thermostat to help with dehumidification from the equipment. Recommended a low set point homeowner was ok with 74 degrees. Found sofets were painted over and causing a lack of airflow in the attic. Gable fan is install and operating. Two gable vents are present. Replacing the sofets will improve airflow in attic lowing attic humidity. Attic are is also leaking into home in many spots. Recommended trying the sofets and thermostat changes first. But if the issue persists they should look into air sealing of the attic.
St. Petersburg, FL 33703
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Fan motor is pulling 1.4 amps with a max rating of .74. I found the fan motor was wired into the compressor side of the capacitor. I moved the wire to the proper terminal and checked that the fan motor is pulling .6 amps now.   Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 22° temperature split at this time.

Client says that it seems like the system has always struggled to maintain temperature at 77° during the middle of the day. 
I discovered that they have a 3 ton system installed in a 2000sqft home. This system is not big enough for this size home to cool efficiently. 
Duct work is also sized too small for a 4 ton system. 
The duct work and system installed currentl
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Fan motor is pulling 1.4 amps with a max rating of .74. I found the fan motor was wired into the compressor side of the capacitor. I moved the wire to the proper terminal and checked that the fan motor is pulling .6 amps now.   Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 22° temperature split at this time.

Client says that it seems like the system has always struggled to maintain temperature at 77° during the middle of the day. 
I discovered that they have a 3 ton system installed in a 2000sqft home. This system is not big enough for this size home to cool efficiently. 
Duct work is also sized too small for a 4 ton system. 
The duct work and system installed currentl
Michael A.
Michael A. Checked in
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Fan motor is pulling 1.4 amps with a max rating of .74. I found the fan motor was wired into the compressor side of the capacitor. I moved the wire to the proper terminal and checked that the fan motor is pulling .6 amps now. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 22° temperature split at this time. Client says that it seems like the system has always struggled to maintain temperature at 77° during the middle of the day. I discovered that they have a 3 ton system installed in a 2000sqft home. This system is not big enough for this size home to cool efficiently. Duct work is also sized too small for a 4 ton system. The duct work and system installed currentl
St. Petersburg, FL 33703
System has a clogged drain. Performed a drain cleaning and treatment on system. System is cooling with a 19° temperature split. Client signed up for maintenance plan at this property. Client would like us to schedule with tenant for future maintenance.
First Maitenence performed today. 

Found extremely dirty evaporator coils. 
Recommending full pull and clean. 
System needs better air flow for efficiency. 
Tenant needs to change filters with merv 8 filters instead of merv 1 and replace monthly. Tenant stated that he changes his merv 1 filters every 2 weeks however, the evaporator coils are still severely dirty and ridden with hair and debris.
System has a clogged drain. Performed a drain cleaning and treatment on system. System is cooling with a 19° temperature split. Client signed up for maintenance plan at this property. Client would like us to schedule with tenant for future maintenance.
First Maitenence performed today. 

Found extremely dirty evaporator coils. 
Recommending full pull and clean. 
System needs better air flow for efficiency. 
Tenant needs to change filters with merv 8 filters instead of merv 1 and replace monthly. Tenant stated that he changes his merv 1 filters every 2 weeks however, the evaporator coils are still severely dirty and ridden with hair and debris.
Michael A.
Michael A. Checked in
System has a clogged drain. Performed a drain cleaning and treatment on system. System is cooling with a 19° temperature split. Client signed up for maintenance plan at this property. Client would like us to schedule with tenant for future maintenance. First Maitenence performed today. Found extremely dirty evaporator coils. Recommending full pull and clean. System needs better air flow for efficiency. Tenant needs to change filters with merv 8 filters instead of merv 1 and replace monthly. Tenant stated that he changes his merv 1 filters every 2 weeks however, the evaporator coils are still severely dirty and ridden with hair and debris.
St. Petersburg, FL 33711
Replace blower motor. Start and test. Tax and labor included. Unit cooling.
Replace blower motor. Start and test. Tax and labor included. Unit cooling.
Justin G.
Justin G. Checked in
Replace blower motor. Start and test. Tax and labor included. Unit cooling.
St. Petersburg, FL 33711
Upon arrival, the homeowner explained that the system stopped working yesterday. He had already replaced the capacitor and contactor, but the system still would not operate.

Upon further diagnostic testing, I confirmed that proper power was reaching the blower motor; however, the motor was seized and not turning. The blower motor had failed and required replacement. I explained to the homeowner that the motor was out of warranty, so the repair would require payment for both the replacement part and labor.

Due to the overall condition of the system and the amount of money already invested into repairs, I also recommended considering system replacement. The homeowner stated that they are planning to replace the system next year but preferred to proceed with a repair for the time being.

The homeowner approved the blower motor replacement and also enrolled in our maintenance membership, which provides ongoing maintenance and discounted repair pricing. After replacing the blower motor, I
Upon arrival, the homeowner explained that the system stopped working yesterday. He had already replaced the capacitor and contactor, but the system still would not operate.

Upon further diagnostic testing, I confirmed that proper power was reaching the blower motor; however, the motor was seized and not turning. The blower motor had failed and required replacement. I explained to the homeowner that the motor was out of warranty, so the repair would require payment for both the replacement part and labor.

Due to the overall condition of the system and the amount of money already invested into repairs, I also recommended considering system replacement. The homeowner stated that they are planning to replace the system next year but preferred to proceed with a repair for the time being.

The homeowner approved the blower motor replacement and also enrolled in our maintenance membership, which provides ongoing maintenance and discounted repair pricing. After replacing the blower motor, I
ihsan m.
ihsan m. Checked in
Upon arrival, the homeowner explained that the system stopped working yesterday. He had already replaced the capacitor and contactor, but the system still would not operate. Upon further diagnostic testing, I confirmed that proper power was reaching the blower motor; however, the motor was seized and not turning. The blower motor had failed and required replacement. I explained to the homeowner that the motor was out of warranty, so the repair would require payment for both the replacement part and labor. Due to the overall condition of the system and the amount of money already invested into repairs, I also recommended considering system replacement. The homeowner stated that they are planning to replace the system next year but preferred to proceed with a repair for the time being. The homeowner approved the blower motor replacement and also enrolled in our maintenance membership, which provides ongoing maintenance and discounted repair pricing. After replacing the blower motor, I
St. Petersburg, FL 33710
Replace air handler fan control board

Performed drain cleaning complimentary. 
Client signed up for Maitenence plan. 
System is cooling and draining at this time. 

Office offered $50 coupon. Applied coupon to invoice today.
Replace air handler fan control board

Performed drain cleaning complimentary. 
Client signed up for Maitenence plan. 
System is cooling and draining at this time. 

Office offered $50 coupon. Applied coupon to invoice today.
Michael A.
Michael A. Checked in
Replace air handler fan control board Performed drain cleaning complimentary. Client signed up for Maitenence plan. System is cooling and draining at this time. Office offered $50 coupon. Applied coupon to invoice today.
St. Petersburg, FL 33704
Found system tripped on high pressure lock out. 
Reset system and made a couple of adjustments. System is cooling at this time with a 20° temp split. 
There may be an issue with the TXV. Possible floating restriction causing an issue. 
System is cooling and draining at this time.
Found system tripped on high pressure lock out. 
Reset system and made a couple of adjustments. System is cooling at this time with a 20° temp split. 
There may be an issue with the TXV. Possible floating restriction causing an issue. 
System is cooling and draining at this time.
Michael A.
Michael A. Checked in
Found system tripped on high pressure lock out. Reset system and made a couple of adjustments. System is cooling at this time with a 20° temp split. There may be an issue with the TXV. Possible floating restriction causing an issue. System is cooling and draining at this time.
St. Petersburg, FL 33704
On arrival found unit not cooling due to bad blower motor. Will return to replace.
On arrival found unit not cooling due to bad blower motor. Will return to replace.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to bad blower motor. Will return to replace.
St. Petersburg, FL 33711
Reason for call:
Return repair 

Summary:
Replace blower motor. 
Restored operation to equipment unit has 20 degree split. 
Repair has 1 year parts and labor warranty on blower only.
Reason for call:
Return repair 

Summary:
Replace blower motor. 
Restored operation to equipment unit has 20 degree split. 
Repair has 1 year parts and labor warranty on blower only.
Corbin C.
Corbin C. Checked in
Reason for call: Return repair Summary: Replace blower motor. Restored operation to equipment unit has 20 degree split. Repair has 1 year parts and labor warranty on blower only.
St. Petersburg, FL 33703
Review
Great service, came to my place the same day I called. Nate is a great communicator and technician; he kept me informed each step along the way. Nate and Griffin (the electrical technician) are honest, trustworthy, prompt, knowledgeable , and a pleasure to work with. Highly recommend!
Susan A. Valot - St. Petersburg, FL 33703
Response from Air Bros Air Conditioning & Electrical:

Thank you, Susan, for your wonderful 5-star rating; your support means a lot to us!

Review
I had an outstanding experience with Air Bros from the moment I scheduled my service through to the completion of the job. Nate arrived right on schedule and was incredibly professional from start to finish. He performed a thorough preventative maintenance and cleaning of our system with a high attention to detail. He took the time to check our entire system and went above and beyond to answer all my questions in detail about maintenance tips to help prevent future issues. Nate's expertise, friendly demeanor and professionalism along with the entire scheduling process were truly amazing!
Marci Gleicher - St. Petersburg, FL 33704
Response from Air Bros Air Conditioning & Electrical:

Thank you, Marci, for sharing your wonderful experience and recognizing Nate's professionalism and dedication; we truly appreciate your feedback and are glad to know our service met your expectations!

Review
Air Bros has been my go-to for HVAC since I bought my house in 2017, and I wouldnt trust anyone else! Ricky has kept my old unit running like a champ for years, and when my house recently flooded, Justin showed up to get it back up and runningbuying me some time before I finally replace it (after 20 years, its definitely earned its retirement!). Theyre always on time, know their stuff, and even a hit with my dogs. If you want honest, reliable, high-quality service in St. Pete, these guys are the way to go!
Amelia Johnson - St. Petersburg, FL 33704
Response from Air Bros Air Conditioning & Electrical:

Thank you, Amelia, for your kind words and for being a loyal customer since 2017! We're glad to hear that Ricky has kept your unit running smoothly and that Justin was there to help during a tough time. It means a lot to us to know we can provide reliable service for you and your furry friends!

Review
Nathan helped me out on very short notice, super professional and polite. Definitely will call again if need arises.
Ante Gotovina - St. Petersburg, FL 33704
Response from Air Bros Air Conditioning & Electrical:

Thank you, Ante, for your kind words about Nathan's professionalism and quick assistance; we look forward to helping you again in the future!

How do I know if my AC needs repair or full replacement?

Our technicians inspect the full system — age, refrigerant type, corrosion, and repair history — and give you an honest recommendation. If a repair makes sense, we'll fix it. If the unit is beyond its useful life, we'll walk you through replacement options with no pressure.

Are your technicians background-checked and licensed?

Yes. Every Air Bros technician is background-checked, factory-trained, and works under our state HVAC license (#CAC1820499) and electrical license (#EC13015085).

What parts of St. Petersburg do you serve?

We serve all of St. Petersburg, including Downtown, Historic Kenwood, Old Northeast, Snell Isle, Crescent Lake, Shore Acres, and Coquina Key, plus Seminole, Largo, Pinellas Park, and the surrounding beach communities.

Do you offer same-day AC repair in St. Petersburg?

Yes. We offer 24/7 emergency AC repair with same-day service throughout St. Petersburg and the surrounding Pinellas County area.

Is Air Bros a local St. Petersburg company, or a franchise?

Air Bros is 100% locally owned and operated, headquartered in the Shore Acres neighborhood of St. Petersburg. We're not a franchise — every technician is a direct employee, not a subcontractor.

Contact the Bros You Know Today!

Schedule Service Online
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at 727-217-6148 .

Consent
Privacy Policy and Terms & Conditions." required tabindex="20" aria-label="checkbox" aria-required="true" /> By checking this box and submitting this form, you agree to receive marketing, promotional, informational, and customer care text messages from The Air Bros at the mobile number provided. These messages may include special offers, product updates, appointment reminders, account notifications, customer support communications, and other business-related messages. Message frequency varies. Message and data rates may apply. Consent is not a condition of purchase. Reply STOP to opt out at any time or HELP for assistance. View our Privacy Policy and Terms & Conditions.
*
Back Next