Instant Quote Shop Filters Call Air Bros Book Service

St. Petersburg, FL

air-bros-team-with-truck

Your St. Petersburg, FL HVAC Experts

Air Bros Air Conditioning & Heating is proud to serve the vibrant community of St. Petersburg, FL. We understand the unique challenges that St. Petersburg homeowners and businesses face when it comes to maintaining comfortable indoor temperatures year-round. Our team of experienced and certified technicians is dedicated to providing top-quality HVAC services tailored to the specific needs of our St. Petersburg customers.

Call us at 727-217-6148 or contact us online today for all of your HVAC, indoor air quality and electrical needs.

Comprehensive HVAC Services in St. Petersburg

We offer a full range of heating and cooling services to keep your St. Petersburg, FL, home comfortable year-round:

  • Air Conditioning: From AC repair and AC installation to routine maintenance, we ensure your cooling system keeps you comfortable during those hot Florida summers. We offer same-day service for AC emergencies, so you never have to suffer in the heat.
  • Heating: Stay warm and cozy in the winter with our comprehensive heating services. We repair and install all types of heating systems, including furnaces and heat pumps, and offer preventative maintenance to keep your system running efficiently.
  • Indoor Air Quality: Improve your indoor air quality with our dehumidifier and UV light installation services. We'll help you control excess humidity and eliminate airborne contaminants, creating a healthier home environment.
  • Ductwork: Ensure optimal airflow and energy efficiency with our ductwork repair and installation services. We can address leaks and damage, and design a system that's perfect for your home.
  • Pool Heater Services: Extend your swim season with our pool heater installation and repair services.
  • Electrical Services: From outlet and switch replacements to ceiling fan installations to whole-house surge protector installations, we have the experts to handle your electrical service needs.

Our experienced technicians are skilled in all aspects of HVAC service and are dedicated to providing top-quality workmanship and customer care.

Why Choose Air Bros?

  • Local Expertise: We understand the unique climate challenges of St. Petersburg.
  • Fast and Reliable Service: We offer same-day service for AC emergencies and prioritize prompt service for all your HVAC needs.
  • Experienced Technicians: Our team is highly trained and experienced in all aspects of HVAC service.
  • Upfront Pricing: We provide transparent pricing with no hidden costs.
  • Customer Satisfaction Guaranteed: Your comfort and satisfaction are our top priorities.

Contact Air Bros Today!

Whether you need emergency AC repair, a new heating system installation, or any other HVAC service, Air Bros is here to help. Contact us today for a free consultation or to schedule a service appointment. We're proud to be your trusted HVAC partner in St. Petersburg!

Call us at 727-217-6148 or contact us online today!

Our St. Petersburg Location

Address: 1579 Delaware Ave NESt. Petersburg, FL 33703

Phone: 727-217-6148

Count on perfect service; Trust the bros you know!

Recent Jobs and Reviews in St. Petersburg, FL

Job Locations and Reviews

Reason for call:
No cool

Equipment:
2012 nordyne 5 ton 
Horizontal air handler 
Condenser on right of home 

Summary:
On arrival found blower motor failed. Had low voltage calling for blower and high voltage supplied to blower and component was not operating. This would cause coil to freeze. 

Solution:
We will provide repair estimate in the morning. 
We provided replacement option tonight. 
They are trying to reach out to frontier due to frontier cutting a power line under ground during their work today. We can not confirm nor deny this failure being frontiers fault due to the age of the equipment.
Reason for call:
No cool

Equipment:
2012 nordyne 5 ton 
Horizontal air handler 
Condenser on right of home 

Summary:
On arrival found blower motor failed. Had low voltage calling for blower and high voltage supplied to blower and component was not operating. This would cause coil to freeze. 

Solution:
We will provide repair estimate in the morning. 
We provided replacement option tonight. 
They are trying to reach out to frontier due to frontier cutting a power line under ground during their work today. We can not confirm nor deny this failure being frontiers fault due to the age of the equipment.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Equipment: 2012 nordyne 5 ton Horizontal air handler Condenser on right of home Summary: On arrival found blower motor failed. Had low voltage calling for blower and high voltage supplied to blower and component was not operating. This would cause coil to freeze. Solution: We will provide repair estimate in the morning. We provided replacement option tonight. They are trying to reach out to frontier due to frontier cutting a power line under ground during their work today. We can not confirm nor deny this failure being frontiers fault due to the age of the equipment.
St. Petersburg, FL 33702
Reason for call:
No cool

Equipment:
2022 Bosch condenser
2021 Bosch air handler
Horizontal in attic 
Condenser on right side of hom

Summary:
On arrival found system extremely low on charge. Performed leak search to find refrigerant leak within the evaporator coil. Charged up system for free today for temporary cooling due to charging for a refrigerant a month ago and being low on charge once again.

Solution:
Level two evaporator coil replacement under warranty
Reason for call:
No cool

Equipment:
2022 Bosch condenser
2021 Bosch air handler
Horizontal in attic 
Condenser on right side of hom

Summary:
On arrival found system extremely low on charge. Performed leak search to find refrigerant leak within the evaporator coil. Charged up system for free today for temporary cooling due to charging for a refrigerant a month ago and being low on charge once again.

Solution:
Level two evaporator coil replacement under warranty
Corbin C.
Corbin C. Checked in
Reason for call: No cool Equipment: 2022 Bosch condenser 2021 Bosch air handler Horizontal in attic Condenser on right side of hom Summary: On arrival found system extremely low on charge. Performed leak search to find refrigerant leak within the evaporator coil. Charged up system for free today for temporary cooling due to charging for a refrigerant a month ago and being low on charge once again. Solution: Level two evaporator coil replacement under warranty
St. Petersburg, FL 33702
St. Petersburg, FL - On arrival found unit not cooling due to low on refrigerant. Performed leak search and found outdoor coil leaking. Filled with refrigerant for temporary cooling until part can be replaced. Will submit estimate and verify warranty. Unit cooling.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to low on refrigerant. Performed leak search and found outdoor coil leaking. Filled with refrigerant for temporary cooling until part can be replaced. Will submit estimate and verify warranty. Unit cooling.
St. Petersburg, FL 33714
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to bad thermostat. Will return tomorrow to install new thermostat. Unit not cooling.
St. Petersburg, FL 33701
Return visit 

Confirmed system has condensate pump. Pump is in attic area (was not aware or pump first visit)

Pump reservoir is inaccessible due to screws on head unit being rusted out. Home owner will try getting screws out. Once done we can clear pump and verify if pump is operating correctly. Single head unit runs for 1-2 minutes than 1 leg of power shuts off.
Return visit 

Confirmed system has condensate pump. Pump is in attic area (was not aware or pump first visit)

Pump reservoir is inaccessible due to screws on head unit being rusted out. Home owner will try getting screws out. Once done we can clear pump and verify if pump is operating correctly. Single head unit runs for 1-2 minutes than 1 leg of power shuts off.
Nathan A.
Nathan A. Checked in
Return visit Confirmed system has condensate pump. Pump is in attic area (was not aware or pump first visit) Pump reservoir is inaccessible due to screws on head unit being rusted out. Home owner will try getting screws out. Once done we can clear pump and verify if pump is operating correctly. Single head unit runs for 1-2 minutes than 1 leg of power shuts off.
St. Petersburg, FL 33701
Reason for call:
Tune up 

Equipment:
2020 American standard 2 ton 
Horizontal in attic 
Condenser left of home 

Summary:
Completed to find system slightly low in charge. Found drain line leaking slightly. Found uv kit not operating. Flushed indoor and outdoor coils. Flushed drain line and condensation pump. Confirmed pressure and temps. 

Solution:
Charge system top off 
Install locking cap 
Drain line repair due to leaking fittings 
Membership for one unit home as mother in law suite with a unit no membership
Reason for call:
Tune up 

Equipment:
2020 American standard 2 ton 
Horizontal in attic 
Condenser left of home 

Summary:
Completed to find system slightly low in charge. Found drain line leaking slightly. Found uv kit not operating. Flushed indoor and outdoor coils. Flushed drain line and condensation pump. Confirmed pressure and temps. 

Solution:
Charge system top off 
Install locking cap 
Drain line repair due to leaking fittings 
Membership for one unit home as mother in law suite with a unit no membership
Corbin C.
Corbin C. Checked in
Reason for call: Tune up Equipment: 2020 American standard 2 ton Horizontal in attic Condenser left of home Summary: Completed to find system slightly low in charge. Found drain line leaking slightly. Found uv kit not operating. Flushed indoor and outdoor coils. Flushed drain line and condensation pump. Confirmed pressure and temps. Solution: Charge system top off Install locking cap Drain line repair due to leaking fittings Membership for one unit home as mother in law suite with a unit no membership
St. Petersburg, FL 33703
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is not within factory range. Recommended replacing capacitor but client will wait till it fails. Inspected Contactar and found it is buzzing slightly. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.

System is older and air handler is condensating into the secondary pan. Let client know and if it becomes a problem we will diagnose what is causing it. Likely due to old age and poor connections to the duct work.
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is not within factory range. Recommended replacing capacitor but client will wait till it fails. Inspected Contactar and found it is buzzing slightly. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.

System is older and air handler is condensating into the secondary pan. Let client know and if it becomes a problem we will diagnose what is causing it. Likely due to old age and poor connections to the duct work.
Michael A.
Michael A. Checked in
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is not within factory range. Recommended replacing capacitor but client will wait till it fails. Inspected Contactar and found it is buzzing slightly. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. System is older and air handler is condensating into the secondary pan. Let client know and if it becomes a problem we will diagnose what is causing it. Likely due to old age and poor connections to the duct work.
St. Petersburg, FL 33712
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to insulation in plenum falling and blocking air flow. Removed insulation. Plenum is also wrapped on outside. Turned unit back on. Good air flow. Unit cooling.
St. Petersburg, FL 33701
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Added chemical to help prevent growth. Performed maintenance on system. Electrical checked good. Pressures and temp split in range. Rinsed outdoor coil. Indoor coil clean. Blower dirty. U it cooling and draining at this time.
St. Petersburg, FL 33701
Client states strange smell coming from system. Client wanted a coil cleaning to help with the smell. Upon my inspection, found a refrigerant leak in the evaporator coil. This coil is not manufactured anymore and cannot be replaced. Quotes being sent for new system options.
Client states strange smell coming from system. Client wanted a coil cleaning to help with the smell. Upon my inspection, found a refrigerant leak in the evaporator coil. This coil is not manufactured anymore and cannot be replaced. Quotes being sent for new system options.
Michael A.
Michael A. Checked in
Client states strange smell coming from system. Client wanted a coil cleaning to help with the smell. Upon my inspection, found a refrigerant leak in the evaporator coil. This coil is not manufactured anymore and cannot be replaced. Quotes being sent for new system options.
St. Petersburg, FL 33702
Upon arrival, I checked the temperature difference between the supply and return air and recorded a 20° split, which is within the proper operating range. I then inspected the electrical components and found no shorts, burnouts, or signs of electrical failure. The compressor and condenser fan motor were both operating within proper amperage specifications.

I performed a drain line treatment, cleaned the condenser coil, and completed a full air handler inspection. The system already has a UV light installed and operating.

If you have any questions, please feel free to reach out. Thank you for your business, and have a great day.
Upon arrival, I checked the temperature difference between the supply and return air and recorded a 20° split, which is within the proper operating range. I then inspected the electrical components and found no shorts, burnouts, or signs of electrical failure. The compressor and condenser fan motor were both operating within proper amperage specifications.

I performed a drain line treatment, cleaned the condenser coil, and completed a full air handler inspection. The system already has a UV light installed and operating.

If you have any questions, please feel free to reach out. Thank you for your business, and have a great day.
ihsan m.
ihsan m. Checked in
Upon arrival, I checked the temperature difference between the supply and return air and recorded a 20° split, which is within the proper operating range. I then inspected the electrical components and found no shorts, burnouts, or signs of electrical failure. The compressor and condenser fan motor were both operating within proper amperage specifications. I performed a drain line treatment, cleaned the condenser coil, and completed a full air handler inspection. The system already has a UV light installed and operating. If you have any questions, please feel free to reach out. Thank you for your business, and have a great day.
St. Petersburg, FL 33703
Reason for call:
company that installed is not responding* 
power not connected to rc wiring alert on thermostat
unit not cooling 

Summary:
Completed service to find float switch tripped. Drain line is clogged. Cleared drain line by blowing it with nitro. Confirmed proper temps, pressures and amps. Informed homeowner about our membership plan so we can prevent break downs like this in the future. 
Also noticed lights flicker when unit kicks on. Mentions this to homeowner. It happens with many item throughout the house not just ac. Informed her about soft start kit. She has been told the hose needs to be rewired.
Reason for call:
company that installed is not responding* 
power not connected to rc wiring alert on thermostat
unit not cooling 

Summary:
Completed service to find float switch tripped. Drain line is clogged. Cleared drain line by blowing it with nitro. Confirmed proper temps, pressures and amps. Informed homeowner about our membership plan so we can prevent break downs like this in the future. 
Also noticed lights flicker when unit kicks on. Mentions this to homeowner. It happens with many item throughout the house not just ac. Informed her about soft start kit. She has been told the hose needs to be rewired.
Corbin C.
Corbin C. Checked in
Reason for call: company that installed is not responding* power not connected to rc wiring alert on thermostat unit not cooling Summary: Completed service to find float switch tripped. Drain line is clogged. Cleared drain line by blowing it with nitro. Confirmed proper temps, pressures and amps. Informed homeowner about our membership plan so we can prevent break downs like this in the future. Also noticed lights flicker when unit kicks on. Mentions this to homeowner. It happens with many item throughout the house not just ac. Informed her about soft start kit. She has been told the hose needs to be rewired.
St. Petersburg, FL 33704
Remove Current Flex Ducting 
Duct Balancing & CFM Measurements 
Remove Back Bedrooms Ducting 
Remove Back Bathroom Ducting 
Install Main Feed to Mixing Box
Mixing Box Supply to Kitchen 
Mixing Box 4” Supply to Washer/Dryer 
Install 4” Ceiling Boot & Register 
Replace All Supply Ducting From Plenum 
Strap All Ducting to Code 
Seal All Ducting to Code 

10 Year No Leak Guarantee
Remove Current Flex Ducting 
Duct Balancing & CFM Measurements 
Remove Back Bedrooms Ducting 
Remove Back Bathroom Ducting 
Install Main Feed to Mixing Box
Mixing Box Supply to Kitchen 
Mixing Box 4” Supply to Washer/Dryer 
Install 4” Ceiling Boot & Register 
Replace All Supply Ducting From Plenum 
Strap All Ducting to Code 
Seal All Ducting to Code 

10 Year No Leak Guarantee
Kyle K.
Kyle K. Checked in
Remove Current Flex Ducting Duct Balancing & CFM Measurements Remove Back Bedrooms Ducting Remove Back Bathroom Ducting Install Main Feed to Mixing Box Mixing Box Supply to Kitchen Mixing Box 4” Supply to Washer/Dryer Install 4” Ceiling Boot & Register Replace All Supply Ducting From Plenum Strap All Ducting to Code Seal All Ducting to Code 10 Year No Leak Guarantee
St. Petersburg, FL 33707
Return to complete repairs 

Outdoor Condenser Scope of Work
-chemically rinse coils inside and out 
-replace outdoor contactor
-replace outdoor defrost board 
-replace outdoor fan motor 
-insulate outdoor refrigerant lines 
-clean service panel 

Indoor Air Handler 
-remove & sanitize blower wheel 
-sanitize wiring and interior cabinet 
-flush drain line 
-seal duct distribution box 
-patch insulation hole on refrigerant lines 

Verified system operations after completing work. Unit is operating within manufacture specifications
Return to complete repairs 

Outdoor Condenser Scope of Work
-chemically rinse coils inside and out 
-replace outdoor contactor
-replace outdoor defrost board 
-replace outdoor fan motor 
-insulate outdoor refrigerant lines 
-clean service panel 

Indoor Air Handler 
-remove & sanitize blower wheel 
-sanitize wiring and interior cabinet 
-flush drain line 
-seal duct distribution box 
-patch insulation hole on refrigerant lines 

Verified system operations after completing work. Unit is operating within manufacture specifications
Nathan A.
Nathan A. Checked in
Return to complete repairs Outdoor Condenser Scope of Work -chemically rinse coils inside and out -replace outdoor contactor -replace outdoor defrost board -replace outdoor fan motor -insulate outdoor refrigerant lines -clean service panel Indoor Air Handler -remove & sanitize blower wheel -sanitize wiring and interior cabinet -flush drain line -seal duct distribution box -patch insulation hole on refrigerant lines Verified system operations after completing work. Unit is operating within manufacture specifications
St. Petersburg, FL 33713
Justin G.
Justin G. Checked in
Replace Redlink thermostat and sensor. Start and test. Unit has 20* split and temp is dropping.
St. Petersburg, FL 33701
Scope of work:
- Remove blower assembly
- Clean and sanitize
- Install UV system (discounted extra with bundle)
- Re install blower assembly
- Test system.
Scope of work:
- Remove blower assembly
- Clean and sanitize
- Install UV system (discounted extra with bundle)
- Re install blower assembly
- Test system.
Michael A.
Michael A. Checked in
Scope of work: - Remove blower assembly - Clean and sanitize - Install UV system (discounted extra with bundle) - Re install blower assembly - Test system.
St. Petersburg, FL 33704
Diagnostic:

System had a refrigerant leak. After performing a leak search, I found the leak in the evaporator coil. I discussed the findings with the homeowner, and we decided to move forward with replacing the evaporator coil under warranty. Please reach out to the customer once scheduling is available so we can coordinate the installation.

Repair:

Upon arrival, I removed the existing evaporator coil and installed the new warranty replacement coil. I also replaced the filter drier at the condenser. After completing the installation, I performed a nitrogen pressure test, which held successfully for 20 minutes with no loss of pressure. I then pulled a vacuum on the system for approximately one hour and achieved a vacuum level of 600 microns.

Once the system was started, I added refrigerant as needed and verified proper system operation. The system is currently operating with an 18° temperature difference between return air and supply air, and refrigerant pressures are within normal
Diagnostic:

System had a refrigerant leak. After performing a leak search, I found the leak in the evaporator coil. I discussed the findings with the homeowner, and we decided to move forward with replacing the evaporator coil under warranty. Please reach out to the customer once scheduling is available so we can coordinate the installation.

Repair:

Upon arrival, I removed the existing evaporator coil and installed the new warranty replacement coil. I also replaced the filter drier at the condenser. After completing the installation, I performed a nitrogen pressure test, which held successfully for 20 minutes with no loss of pressure. I then pulled a vacuum on the system for approximately one hour and achieved a vacuum level of 600 microns.

Once the system was started, I added refrigerant as needed and verified proper system operation. The system is currently operating with an 18° temperature difference between return air and supply air, and refrigerant pressures are within normal
ihsan m.
ihsan m. Checked in
Diagnostic: System had a refrigerant leak. After performing a leak search, I found the leak in the evaporator coil. I discussed the findings with the homeowner, and we decided to move forward with replacing the evaporator coil under warranty. Please reach out to the customer once scheduling is available so we can coordinate the installation. Repair: Upon arrival, I removed the existing evaporator coil and installed the new warranty replacement coil. I also replaced the filter drier at the condenser. After completing the installation, I performed a nitrogen pressure test, which held successfully for 20 minutes with no loss of pressure. I then pulled a vacuum on the system for approximately one hour and achieved a vacuum level of 600 microns. Once the system was started, I added refrigerant as needed and verified proper system operation. The system is currently operating with an 18° temperature difference between return air and supply air, and refrigerant pressures are within normal
St. Petersburg, FL 33702
Made corrections to failed inspection. Cleared drains. Strapped flu pipe to allow proper uphill flow for exhaust gas. Sealed plenum with code tape and mastic.
Made corrections to failed inspection. Cleared drains. Strapped flu pipe to allow proper uphill flow for exhaust gas. Sealed plenum with code tape and mastic.
Justin G.
Justin G. Checked in
Made corrections to failed inspection. Cleared drains. Strapped flu pipe to allow proper uphill flow for exhaust gas. Sealed plenum with code tape and mastic.
St. Petersburg, FL 33703
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is not within factory range. Recommending replacing capacitor but client would like to leave it. Advised client on the stress this weak capacitor may put on the system. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.

Inside air handler there is biological growth present. Showed client and offered cleaning with a UV system. Client would like to hold off for now.
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is not within factory range. Recommending replacing capacitor but client would like to leave it. Advised client on the stress this weak capacitor may put on the system. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.

Inside air handler there is biological growth present. Showed client and offered cleaning with a UV system. Client would like to hold off for now.
Michael A.
Michael A. Checked in
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is not within factory range. Recommending replacing capacitor but client would like to leave it. Advised client on the stress this weak capacitor may put on the system. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. Inside air handler there is biological growth present. Showed client and offered cleaning with a UV system. Client would like to hold off for now.
St. Petersburg, FL 33702
Ricky O.
Ricky O. Checked in
Client requested float switch primary be installed I installed switch and informed client that this would not prevent future water issues as his secondary pan is rusted out. Quoted to replace secondary pan 300$ Quoted to perform leak check 250$ Quoted to fill system with Freon 450$ Quoted estimated repairs 2500-3000$ Quoted new system with ceiling repair 11,500$
St. Petersburg, FL 33702
3T Carrier Heat Pump 

Full System Tuneup 

Notes 
-indoor and outdoor unit flooded 
-air handler coils were submerged (corrosion on txv)
-outdoor compressor was submerged 
-indoor blower wheel & cabinet have bacterial growth 
-supply plenum not sealed properly (growth accumulating)
-outdoor capacitor reading very weak 
-system has a restriction 

System is 7-8 years old and currently out of manufacture warranty (2nd owner of system)

Went over repair and replacement options 

Home owner would like to wait till system fails 

Unit is not operating to full capacity
3T Carrier Heat Pump 

Full System Tuneup 

Notes 
-indoor and outdoor unit flooded 
-air handler coils were submerged (corrosion on txv)
-outdoor compressor was submerged 
-indoor blower wheel & cabinet have bacterial growth 
-supply plenum not sealed properly (growth accumulating)
-outdoor capacitor reading very weak 
-system has a restriction 

System is 7-8 years old and currently out of manufacture warranty (2nd owner of system)

Went over repair and replacement options 

Home owner would like to wait till system fails 

Unit is not operating to full capacity
Nathan A.
Nathan A. Checked in
3T Carrier Heat Pump Full System Tuneup Notes -indoor and outdoor unit flooded -air handler coils were submerged (corrosion on txv) -outdoor compressor was submerged -indoor blower wheel & cabinet have bacterial growth -supply plenum not sealed properly (growth accumulating) -outdoor capacitor reading very weak -system has a restriction System is 7-8 years old and currently out of manufacture warranty (2nd owner of system) Went over repair and replacement options Home owner would like to wait till system fails Unit is not operating to full capacity
St. Petersburg, FL 33703
Performed maintenance on 1 system. Pressures good. Temp split good. Rinsed condenser coil. Cleared pan and drain. Added chemical to help prevent growth. Tested secondary float switch. Unit is cooling properly at this time. 
Unit is 14” Frigidaire in very tight attic. Pan was extremely clogged with growth. Primary float unable to be used due to improper install. Recommend regular maintenance to prevent further issues with drain.
Performed maintenance on 1 system. Pressures good. Temp split good. Rinsed condenser coil. Cleared pan and drain. Added chemical to help prevent growth. Tested secondary float switch. Unit is cooling properly at this time. 
Unit is 14” Frigidaire in very tight attic. Pan was extremely clogged with growth. Primary float unable to be used due to improper install. Recommend regular maintenance to prevent further issues with drain.
Justin G.
Justin G. Checked in
Performed maintenance on 1 system. Pressures good. Temp split good. Rinsed condenser coil. Cleared pan and drain. Added chemical to help prevent growth. Tested secondary float switch. Unit is cooling properly at this time. Unit is 14” Frigidaire in very tight attic. Pan was extremely clogged with growth. Primary float unable to be used due to improper install. Recommend regular maintenance to prevent further issues with drain.
St. Petersburg, FL 33703
Justin G.
Justin G. Checked in
On arrival found master unit not cooling due to blown fuse. Replaced fuse and tested. Inspected inside and outside unit for possible short that caused fuse to fail. Unable to locate short at this time. Unit has 20* split and cooling at this time.
St. Petersburg, FL 33704
Upon arrival, I turned on the air handler, which was operating properly. I checked the temperature difference between the supply and return air and was getting a 0° split. I then moved to the condenser and found that the condenser was not turning on. After opening the electrical compartment and testing components, I found the capacitor was burnt out. 

I installed a temporary capacitor, and the system turned on properly. I allowed the system to run for approximately 15 minutes and rechecked the temperature split, which was then reading 18°, placing the system in a healthy operating range at this time.

I discussed with the homeowner that the system is quite old and has already had previous repairs. I recommended considering system replacement in the near future rather than continuing to invest money into an aging system. The homeowner stated they are moving out soon and only wanted a temporary repair at this time.

If you have any questions, please feel free to reach out. Thank you for
Upon arrival, I turned on the air handler, which was operating properly. I checked the temperature difference between the supply and return air and was getting a 0° split. I then moved to the condenser and found that the condenser was not turning on. After opening the electrical compartment and testing components, I found the capacitor was burnt out. 

I installed a temporary capacitor, and the system turned on properly. I allowed the system to run for approximately 15 minutes and rechecked the temperature split, which was then reading 18°, placing the system in a healthy operating range at this time.

I discussed with the homeowner that the system is quite old and has already had previous repairs. I recommended considering system replacement in the near future rather than continuing to invest money into an aging system. The homeowner stated they are moving out soon and only wanted a temporary repair at this time.

If you have any questions, please feel free to reach out. Thank you for
ihsan m.
ihsan m. Checked in
Upon arrival, I turned on the air handler, which was operating properly. I checked the temperature difference between the supply and return air and was getting a 0° split. I then moved to the condenser and found that the condenser was not turning on. After opening the electrical compartment and testing components, I found the capacitor was burnt out. I installed a temporary capacitor, and the system turned on properly. I allowed the system to run for approximately 15 minutes and rechecked the temperature split, which was then reading 18°, placing the system in a healthy operating range at this time. I discussed with the homeowner that the system is quite old and has already had previous repairs. I recommended considering system replacement in the near future rather than continuing to invest money into an aging system. The homeowner stated they are moving out soon and only wanted a temporary repair at this time. If you have any questions, please feel free to reach out. Thank you for
St. Petersburg, FL 33710
Client states unit is not cooling but thermostat is on. Upon my inspection, found clogged drain line and the safety float switch was tripped. Performed a drain cleaning/ treatment. Started up system and found compressor is pulling high amps. Inspected condenser coils and found dirty coils. Pressures indicate too much refrigerant in system. Client says they had compressor replaced last year by another company. It appears that the best practices installing a compressor were not followed based on copper connections and the amount of refrigerant in the system. 

Cleaned/ treated drain line and primary drain pan. 
Chemical cleaned condenser coils with fan removed. 
Adjusted refrigerant charge to achieve proper subcool. 

Found condenser disconnect is damaged and requires replacement. Will return later this week to replace. 

Compressor pulls high amps are starting to up. Recommended soft start kit to reduce amp draw and prolong the life of the compressor.
Client states unit is not cooling but thermostat is on. Upon my inspection, found clogged drain line and the safety float switch was tripped. Performed a drain cleaning/ treatment. Started up system and found compressor is pulling high amps. Inspected condenser coils and found dirty coils. Pressures indicate too much refrigerant in system. Client says they had compressor replaced last year by another company. It appears that the best practices installing a compressor were not followed based on copper connections and the amount of refrigerant in the system. 

Cleaned/ treated drain line and primary drain pan. 
Chemical cleaned condenser coils with fan removed. 
Adjusted refrigerant charge to achieve proper subcool. 

Found condenser disconnect is damaged and requires replacement. Will return later this week to replace. 

Compressor pulls high amps are starting to up. Recommended soft start kit to reduce amp draw and prolong the life of the compressor.
Michael A.
Michael A. Checked in
Client states unit is not cooling but thermostat is on. Upon my inspection, found clogged drain line and the safety float switch was tripped. Performed a drain cleaning/ treatment. Started up system and found compressor is pulling high amps. Inspected condenser coils and found dirty coils. Pressures indicate too much refrigerant in system. Client says they had compressor replaced last year by another company. It appears that the best practices installing a compressor were not followed based on copper connections and the amount of refrigerant in the system. Cleaned/ treated drain line and primary drain pan. Chemical cleaned condenser coils with fan removed. Adjusted refrigerant charge to achieve proper subcool. Found condenser disconnect is damaged and requires replacement. Will return later this week to replace. Compressor pulls high amps are starting to up. Recommended soft start kit to reduce amp draw and prolong the life of the compressor.
St. Petersburg, FL 33703
Review
Great service, came to my place the same day I called. Nate is a great communicator and technician; he kept me informed each step along the way. Nate and Griffin (the electrical technician) are honest, trustworthy, prompt, knowledgeable , and a pleasure to work with. Highly recommend!
Susan A. Valot - St. Petersburg, FL 33703
Response from Air Bros Air Conditioning & Electrical:

Thank you, Susan, for your wonderful 5-star rating; your support means a lot to us!

Review
I had an outstanding experience with Air Bros from the moment I scheduled my service through to the completion of the job. Nate arrived right on schedule and was incredibly professional from start to finish. He performed a thorough preventative maintenance and cleaning of our system with a high attention to detail. He took the time to check our entire system and went above and beyond to answer all my questions in detail about maintenance tips to help prevent future issues. Nate's expertise, friendly demeanor and professionalism along with the entire scheduling process were truly amazing!
Marci Gleicher - St. Petersburg, FL 33704
Response from Air Bros Air Conditioning & Electrical:

Thank you, Marci, for sharing your wonderful experience and recognizing Nate's professionalism and dedication; we truly appreciate your feedback and are glad to know our service met your expectations!

Review
Air Bros has been my go-to for HVAC since I bought my house in 2017, and I wouldnt trust anyone else! Ricky has kept my old unit running like a champ for years, and when my house recently flooded, Justin showed up to get it back up and runningbuying me some time before I finally replace it (after 20 years, its definitely earned its retirement!). Theyre always on time, know their stuff, and even a hit with my dogs. If you want honest, reliable, high-quality service in St. Pete, these guys are the way to go!
Amelia Johnson - St. Petersburg, FL 33704
Response from Air Bros Air Conditioning & Electrical:

Thank you, Amelia, for your kind words and for being a loyal customer since 2017! We're glad to hear that Ricky has kept your unit running smoothly and that Justin was there to help during a tough time. It means a lot to us to know we can provide reliable service for you and your furry friends!

Review
Nathan helped me out on very short notice, super professional and polite. Definitely will call again if need arises.
Ante Gotovina - St. Petersburg, FL 33704
Response from Air Bros Air Conditioning & Electrical:

Thank you, Ante, for your kind words about Nathan's professionalism and quick assistance; we look forward to helping you again in the future!

Contact the Bros You Know Today!

Schedule Service Online
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at 727-217-6148 .

By pressing Submit I agree to receive phone, email, or text messages from Air Bros Air Conditioning & Heating to the provided mobile number and also agree to the Air Bros Air Conditioning & Heating terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next