Instant Quote Shop Filters Call Air Bros

Largo, FL

air-bros-team-with-truck

Largo, FL, Home Comfort Solutions

As a locally owned and operated company, Air Bros is proud to be a part of the Largo community. We understand the challenges that Florida's heat and humidity can bring, and we're dedicated to providing our neighbors with reliable HVAC solutions to keep their homes comfortable year-round. Whether you're just steps from the Gulf or nestled in a quiet neighborhood, you can count on Air Bros for top-notch service and personalized solutions.

Call us at 727-217-6148 or contact us online.

Why Choose Air Bros in Largo?

  • Local Expertise: We're familiar with the unique climate challenges of Largo and the specific needs of its residents.
  • Customer-Focused Approach: Your comfort and satisfaction are our top priorities. We listen to your concerns, answer your questions, and provide tailored solutions that fit your needs and budget.
  • Experienced and Certified Technicians: Our team consists of highly skilled and certified technicians with extensive experience in all aspects of HVAC service. You can trust us to get the job done right.
  • Fast and Reliable Service: We know that HVAC issues can be disruptive. That's why we prioritize prompt and reliable service, offering same-day service for AC emergencies and quick response times for all your HVAC needs.
  • Upfront Pricing: We believe in transparency and honesty. You'll always receive upfront pricing with no hidden costs or surprises.

Comprehensive HVAC Services in Largo, FL

  • Complete Comfort Solutions: We're your one-stop shop for heating and cooling in Largo. Whether you need AC repair on a scorching summer day or a new furnace installed before winter arrives, our expert technicians have you covered. We service all makes and models, ensuring your home stays comfortable no matter the season.
  • Healthy Indoor Air: We go beyond temperature control to ensure the air you breathe is clean and healthy. Our indoor air quality solutions, including dehumidifiers and UV light air purifiers, help control humidity, eliminate allergens, and create a healthier home environment for you and your family.
  • Efficient Airflow: Your ductwork plays a crucial role in your home's comfort and energy efficiency. Our professional ductwork services ensure optimal airflow, prevent energy waste, and improve the overall performance of your HVAC system.

Beyond the Basics

  • Pool Heater Services: Enjoy your pool year-round with our pool heater installation and repair services.
  • Electrical Services: We can handle your electrical needs, including outlet and switch replacements, ceiling fan installations, and whole-house surge protector installations.

Contact Air Bros Today!

We're your trusted HVAC partner in Largo. Contact us today for a free consultation or to schedule a service appointment. Experience the Air Bros difference!

Call us at 727-217-6148 or contact us online.

Recent Jobs and Reviews in Largo, FL

Job Locations and Reviews

Upon my inspection, found thermostat has a humid stack connected to it that was not set properly. The humid thermostat was not allowing the system to turn on. I set the humid stat to the on position and the system turns on and turns off with the thermostat only now. System is cooling with a 20° temperature split. Looked over the condenser and found no apparent issues at this time.
Recommended that Client set up a maintenance soon.
Upon my inspection, found thermostat has a humid stack connected to it that was not set properly. The humid thermostat was not allowing the system to turn on. I set the humid stat to the on position and the system turns on and turns off with the thermostat only now. System is cooling with a 20° temperature split. Looked over the condenser and found no apparent issues at this time.
Recommended that Client set up a maintenance soon.
Michael A.
Michael A. Checked in
Upon my inspection, found thermostat has a humid stack connected to it that was not set properly. The humid thermostat was not allowing the system to turn on. I set the humid stat to the on position and the system turns on and turns off with the thermostat only now. System is cooling with a 20° temperature split. Looked over the condenser and found no apparent issues at this time. Recommended that Client set up a maintenance soon.
Largo, FL 33774
Reason for call:
No cool 

Summary:
Found failed capacitor. Found buzzing contactor. 
Restored operation to equipment. 
Homeowner is not Intrested in maintenance plan. 
Unit cooling by 18 degrees 

Replace capacitor and contactor to restore operation to equipment
Reason for call:
No cool 

Summary:
Found failed capacitor. Found buzzing contactor. 
Restored operation to equipment. 
Homeowner is not Intrested in maintenance plan. 
Unit cooling by 18 degrees 

Replace capacitor and contactor to restore operation to equipment
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: Found failed capacitor. Found buzzing contactor. Restored operation to equipment. Homeowner is not Intrested in maintenance plan. Unit cooling by 18 degrees Replace capacitor and contactor to restore operation to equipment
Largo, FL 33771
Upon arrival, I began by inspecting the outdoor condenser. I found that the compressor was running, but the condenser fan motor was not operating. Further diagnostic testing determined that the capacitor had failed.

I replaced the faulty capacitor and inspected the contactor to ensure proper operation and prevent potential premature failure. After completing the repair, I verified that the system was operating properly.

I also signed the homeowners up for our maintenance plan, which will help keep the system operating efficiently and allow us to identify potential issues before they become major repairs.

If you have any questions or concerns, please feel free to reach out. Thank you for your business, and have a great day!
Upon arrival, I began by inspecting the outdoor condenser. I found that the compressor was running, but the condenser fan motor was not operating. Further diagnostic testing determined that the capacitor had failed.

I replaced the faulty capacitor and inspected the contactor to ensure proper operation and prevent potential premature failure. After completing the repair, I verified that the system was operating properly.

I also signed the homeowners up for our maintenance plan, which will help keep the system operating efficiently and allow us to identify potential issues before they become major repairs.

If you have any questions or concerns, please feel free to reach out. Thank you for your business, and have a great day!
ihsan m.
ihsan m. Checked in
Upon arrival, I began by inspecting the outdoor condenser. I found that the compressor was running, but the condenser fan motor was not operating. Further diagnostic testing determined that the capacitor had failed. I replaced the faulty capacitor and inspected the contactor to ensure proper operation and prevent potential premature failure. After completing the repair, I verified that the system was operating properly. I also signed the homeowners up for our maintenance plan, which will help keep the system operating efficiently and allow us to identify potential issues before they become major repairs. If you have any questions or concerns, please feel free to reach out. Thank you for your business, and have a great day!
Largo, FL 33773
Upon arrival, the workers at the home explained that the system had been struggling to maintain a temperature below 74°F during the daytime. I performed a complete diagnostic of the system and found a 19°F temperature split, indicating the system is cooling properly. The refrigerant cycle was operating within a healthy range, and all electrical components were functioning properly with no signs of excessive amperage or components struggling under load.

Based on the diagnostic findings and further discussion, it appears the primary concern is related to the outdoor conditions. With outdoor temperatures reaching approximately 93°F, it is not always realistic for the system to maintain temperatures below 74°F during the hottest part of the day, particularly depending on the home’s insulation, ductwork, windows, occupancy, and overall heat load.

While the system was running during the visit, the indoor temperature dropped an additional degree to 73°F, confirming that the system is active
Upon arrival, the workers at the home explained that the system had been struggling to maintain a temperature below 74°F during the daytime. I performed a complete diagnostic of the system and found a 19°F temperature split, indicating the system is cooling properly. The refrigerant cycle was operating within a healthy range, and all electrical components were functioning properly with no signs of excessive amperage or components struggling under load.

Based on the diagnostic findings and further discussion, it appears the primary concern is related to the outdoor conditions. With outdoor temperatures reaching approximately 93°F, it is not always realistic for the system to maintain temperatures below 74°F during the hottest part of the day, particularly depending on the home’s insulation, ductwork, windows, occupancy, and overall heat load.

While the system was running during the visit, the indoor temperature dropped an additional degree to 73°F, confirming that the system is active
ihsan m.
ihsan m. Checked in
Upon arrival, the workers at the home explained that the system had been struggling to maintain a temperature below 74°F during the daytime. I performed a complete diagnostic of the system and found a 19°F temperature split, indicating the system is cooling properly. The refrigerant cycle was operating within a healthy range, and all electrical components were functioning properly with no signs of excessive amperage or components struggling under load. Based on the diagnostic findings and further discussion, it appears the primary concern is related to the outdoor conditions. With outdoor temperatures reaching approximately 93°F, it is not always realistic for the system to maintain temperatures below 74°F during the hottest part of the day, particularly depending on the home’s insulation, ductwork, windows, occupancy, and overall heat load. While the system was running during the visit, the indoor temperature dropped an additional degree to 73°F, confirming that the system is active
Largo, FL 33778
Ricky O.
Ricky O. Checked in
System is 20 years old and low on refrigerant. Talked to landlord who lives out of state. He wants me to send him a quote
Largo, FL 33774
Ricky O.
Ricky O. Checked in
Replaced warranty cap
Largo, FL 33771
Replace evaporator coil under parts warranty
Replace filter dryer
Vacuum system
Critically charge system


Competed repair proper operation was restored to the equipment.
Replace evaporator coil under parts warranty
Replace filter dryer
Vacuum system
Critically charge system


Competed repair proper operation was restored to the equipment.
Corbin C.
Corbin C. Checked in
Replace evaporator coil under parts warranty Replace filter dryer Vacuum system Critically charge system Competed repair proper operation was restored to the equipment.
Largo, FL 33771
Performed tune up on system. 
Cleaned and treated drain line. Cleaned condenser coils. Performed full inspection on system. 
Amp draws are good. 
Primary drain pan is holding excess water and it is escaping the pan and saturating the bottom of the furnace/air handler. This is due to the evaporator coils being improperly installed and not properly leveled. 
Blower wheel is dirty and impacted with bacterial growth
Found media filter in air handler that hasn’t been changed in a long time and client was unaware of its existence. Removed and made sure there was a filter in the ceiling. 
Drain line is missing insulation and is sweating with condensation as it is exposed to the hot garage air. 
At the condenser I found a weak capacitor and contactar. Replaced these components while here. 

Let client know system is 13 years old and not in the best condition. 
Sending quote for full replacement with new warranties. 
System is cooling at this time with a 20° temperature split. 
System will cont
Performed tune up on system. 
Cleaned and treated drain line. Cleaned condenser coils. Performed full inspection on system. 
Amp draws are good. 
Primary drain pan is holding excess water and it is escaping the pan and saturating the bottom of the furnace/air handler. This is due to the evaporator coils being improperly installed and not properly leveled. 
Blower wheel is dirty and impacted with bacterial growth
Found media filter in air handler that hasn’t been changed in a long time and client was unaware of its existence. Removed and made sure there was a filter in the ceiling. 
Drain line is missing insulation and is sweating with condensation as it is exposed to the hot garage air. 
At the condenser I found a weak capacitor and contactar. Replaced these components while here. 

Let client know system is 13 years old and not in the best condition. 
Sending quote for full replacement with new warranties. 
System is cooling at this time with a 20° temperature split. 
System will cont
Michael A.
Michael A. Checked in
Performed tune up on system. Cleaned and treated drain line. Cleaned condenser coils. Performed full inspection on system. Amp draws are good. Primary drain pan is holding excess water and it is escaping the pan and saturating the bottom of the furnace/air handler. This is due to the evaporator coils being improperly installed and not properly leveled. Blower wheel is dirty and impacted with bacterial growth Found media filter in air handler that hasn’t been changed in a long time and client was unaware of its existence. Removed and made sure there was a filter in the ceiling. Drain line is missing insulation and is sweating with condensation as it is exposed to the hot garage air. At the condenser I found a weak capacitor and contactar. Replaced these components while here. Let client know system is 13 years old and not in the best condition. Sending quote for full replacement with new warranties. System is cooling at this time with a 20° temperature split. System will cont
Largo, FL 33774
Michael A.
Michael A. Checked in
Upon my inspection, found system not cooling due to a seized up condenser fan motor and a failed start/run capacitor. Thermostat inside is faulty and not showing the display properly. Replaced the condenser fan motor, replaced the capacitor, replaced the thermostat and programmed. Made sure all connections are tight. Started system and system is now cooling with a 20° temperature split. System is operating within manufacture specifications at this time. Inspected evaporator coils and found dirty coils. I let the client know that this will affect efficiency and make the indoor blower motor work harder. Compressor is pulling 11.4 amps with a max rating of 14.1 Waived $95 service fee with repair. 1 year warranty on condenser fan motor 1 year warranty on thermostat 1 year warranty on capacitor
Largo, FL 33770
Upon my inspection, found a severely clogged drain line. Performed drain cleaning on system. System is now draining and cooling with a 20° temperature split. I let the client know that the drain line is not perfectly clean as there is built-up almost cemented debris in the drain line. That is very difficult to remove. If drain line issues persist in the future, I recommended we replace the drain line for guaranteed solution.
Client signed up for Maitenence plan today. Discounts applied and system is cooling at this time.
Upon my inspection, found a severely clogged drain line. Performed drain cleaning on system. System is now draining and cooling with a 20° temperature split. I let the client know that the drain line is not perfectly clean as there is built-up almost cemented debris in the drain line. That is very difficult to remove. If drain line issues persist in the future, I recommended we replace the drain line for guaranteed solution.
Client signed up for Maitenence plan today. Discounts applied and system is cooling at this time.
Michael A.
Michael A. Checked in
Upon my inspection, found a severely clogged drain line. Performed drain cleaning on system. System is now draining and cooling with a 20° temperature split. I let the client know that the drain line is not perfectly clean as there is built-up almost cemented debris in the drain line. That is very difficult to remove. If drain line issues persist in the future, I recommended we replace the drain line for guaranteed solution. Client signed up for Maitenence plan today. Discounts applied and system is cooling at this time.
Largo, FL 33773
Reason for call:
Precision tune up 

Equipment:
2014 package unit Goodman 

Summary:
Completed tune up to find operation of equipment within manufacturing specifications. Found proper temperature. Found proper amp draws. Flushed drain line, pan and coils. Found both the blower capacitor and the main dual capacitor weak. Informed homeowner of age and caps. He decided to replace capacitors. And try and get another couple years out of equipment. 

Solution:
10 mfd for blower 
45/5 mfd for Condneser side of unit
Reason for call:
Precision tune up 

Equipment:
2014 package unit Goodman 

Summary:
Completed tune up to find operation of equipment within manufacturing specifications. Found proper temperature. Found proper amp draws. Flushed drain line, pan and coils. Found both the blower capacitor and the main dual capacitor weak. Informed homeowner of age and caps. He decided to replace capacitors. And try and get another couple years out of equipment. 

Solution:
10 mfd for blower 
45/5 mfd for Condneser side of unit
Corbin C.
Corbin C. Checked in
Reason for call: Precision tune up Equipment: 2014 package unit Goodman Summary: Completed tune up to find operation of equipment within manufacturing specifications. Found proper temperature. Found proper amp draws. Flushed drain line, pan and coils. Found both the blower capacitor and the main dual capacitor weak. Informed homeowner of age and caps. He decided to replace capacitors. And try and get another couple years out of equipment. Solution: 10 mfd for blower 45/5 mfd for Condneser side of unit
Largo, FL 33771
On arrival found unit not cooling due to clogged drain. Cleared pan and drain, added chemical to pan. Performed first maintenance. Electrical checked good. Pressures good. Rinsed outdoor condenser coil. Filter checked and was changed. Unit cooling at this time. 
During clearing of drain, observed line is restricted. Recommend to perform chemical cleaning to help line drain better.
On arrival found unit not cooling due to clogged drain. Cleared pan and drain, added chemical to pan. Performed first maintenance. Electrical checked good. Pressures good. Rinsed outdoor condenser coil. Filter checked and was changed. Unit cooling at this time. 
During clearing of drain, observed line is restricted. Recommend to perform chemical cleaning to help line drain better.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to clogged drain. Cleared pan and drain, added chemical to pan. Performed first maintenance. Electrical checked good. Pressures good. Rinsed outdoor condenser coil. Filter checked and was changed. Unit cooling at this time. During clearing of drain, observed line is restricted. Recommend to perform chemical cleaning to help line drain better.
Largo, FL 33773
Scope of Work
-replace rusted drain pan 
-pitch air handler properly 
-install primary safety overflow switch 
-replace p trap 
-clean drain pan and add pan solution
-clear drain line 
-glue with pvc joints and air handler connections 
-prime drain and trap 

Verified system is draining
Scope of Work
-replace rusted drain pan 
-pitch air handler properly 
-install primary safety overflow switch 
-replace p trap 
-clean drain pan and add pan solution
-clear drain line 
-glue with pvc joints and air handler connections 
-prime drain and trap 

Verified system is draining
Nathan A.
Nathan A. Checked in
Scope of Work -replace rusted drain pan -pitch air handler properly -install primary safety overflow switch -replace p trap -clean drain pan and add pan solution -clear drain line -glue with pvc joints and air handler connections -prime drain and trap Verified system is draining
Largo, FL 33774
Compressor shorted to ground
Compressor shorted to ground
Nathan A.
Nathan A. Checked in
Compressor shorted to ground
Largo, FL 33774
Upon arrival, the homeowner stated that water was leaking through the ceiling and had noticed water around the air handler. After performing a diagnostic, I found that the condensate drain line was clogged, causing water to back up into the system and overflow onto the floor, which resulted in the ceiling leak.

I completed a full system inspection and found a 20°F temperature difference between the supply and return, healthy refrigerant pressures, and all electrical components operating properly.

I performed a condensate drain line treatment and verified that the drain line was flowing and draining properly after the service. At this time, the system is operating as designed.

If you have any questions, please don’t hesitate to reach out. Thank you for your business, and have a great day!
Upon arrival, the homeowner stated that water was leaking through the ceiling and had noticed water around the air handler. After performing a diagnostic, I found that the condensate drain line was clogged, causing water to back up into the system and overflow onto the floor, which resulted in the ceiling leak.

I completed a full system inspection and found a 20°F temperature difference between the supply and return, healthy refrigerant pressures, and all electrical components operating properly.

I performed a condensate drain line treatment and verified that the drain line was flowing and draining properly after the service. At this time, the system is operating as designed.

If you have any questions, please don’t hesitate to reach out. Thank you for your business, and have a great day!
ihsan m.
ihsan m. Checked in
Upon arrival, the homeowner stated that water was leaking through the ceiling and had noticed water around the air handler. After performing a diagnostic, I found that the condensate drain line was clogged, causing water to back up into the system and overflow onto the floor, which resulted in the ceiling leak. I completed a full system inspection and found a 20°F temperature difference between the supply and return, healthy refrigerant pressures, and all electrical components operating properly. I performed a condensate drain line treatment and verified that the drain line was flowing and draining properly after the service. At this time, the system is operating as designed. If you have any questions, please don’t hesitate to reach out. Thank you for your business, and have a great day!
Largo, FL 33771
Found clogged drain line. Cleaned and treated drain line and primary pan. Found system cooling with 10° split. Added 2lbs refrigerant and cleaned condenser coils. System now has good pressures and a 16-17° split. Let client know system may have a refrigerant leak. We will check pressures annd temp split again on next visit.
Found clogged drain line. Cleaned and treated drain line and primary pan. Found system cooling with 10° split. Added 2lbs refrigerant and cleaned condenser coils. System now has good pressures and a 16-17° split. Let client know system may have a refrigerant leak. We will check pressures annd temp split again on next visit.
Michael A.
Michael A. Checked in
Found clogged drain line. Cleaned and treated drain line and primary pan. Found system cooling with 10° split. Added 2lbs refrigerant and cleaned condenser coils. System now has good pressures and a 16-17° split. Let client know system may have a refrigerant leak. We will check pressures annd temp split again on next visit.
Largo, FL 33773
Found bedrooms not cooling properly due to original sheet metal ductwork. Bedrooms are recommended to be on separate mini split systems to guarantee proper comfort for rooms. Client is aware of age of ductwork and main unit. Told client to plan to replace in near future. Unit is cooling to the best of its ability at this time.
Found bedrooms not cooling properly due to original sheet metal ductwork. Bedrooms are recommended to be on separate mini split systems to guarantee proper comfort for rooms. Client is aware of age of ductwork and main unit. Told client to plan to replace in near future. Unit is cooling to the best of its ability at this time.
Justin G.
Justin G. Checked in
Found bedrooms not cooling properly due to original sheet metal ductwork. Bedrooms are recommended to be on separate mini split systems to guarantee proper comfort for rooms. Client is aware of age of ductwork and main unit. Told client to plan to replace in near future. Unit is cooling to the best of its ability at this time.
Largo, FL 33774
Diagnostic 
-drain line backing up causing system to intermittently shut off 
-outside capacitor reading weak on compressor side 
-Subcool value high due to dirty outdoor coils 

Scope of work 
-flush drain line & drain pan 
-added pan tablets to help with buildup 
-clean outdoor condenser coils
-replace outdoor capacitor 
-taped spliced outdoor wiring
-removed failed hard start kit 

Verified system is cooling & draining 
Complimentary cleaned outdoor coils 
Taped outdoor wiring 
Fan speed on low
Diagnostic 
-drain line backing up causing system to intermittently shut off 
-outside capacitor reading weak on compressor side 
-Subcool value high due to dirty outdoor coils 

Scope of work 
-flush drain line & drain pan 
-added pan tablets to help with buildup 
-clean outdoor condenser coils
-replace outdoor capacitor 
-taped spliced outdoor wiring
-removed failed hard start kit 

Verified system is cooling & draining 
Complimentary cleaned outdoor coils 
Taped outdoor wiring 
Fan speed on low
Nathan A.
Nathan A. Checked in
Diagnostic -drain line backing up causing system to intermittently shut off -outside capacitor reading weak on compressor side -Subcool value high due to dirty outdoor coils Scope of work -flush drain line & drain pan -added pan tablets to help with buildup -clean outdoor condenser coils -replace outdoor capacitor -taped spliced outdoor wiring -removed failed hard start kit Verified system is cooling & draining Complimentary cleaned outdoor coils Taped outdoor wiring Fan speed on low
Largo, FL 33770
Replace capacitor 

Replace Contactor

Diagnostic charge 

Cleaned condenser coils 

System is operating 

*Raining during visit
Replace capacitor 

Replace Contactor

Diagnostic charge 

Cleaned condenser coils 

System is operating 

*Raining during visit
Nathan A.
Nathan A. Checked in
Replace capacitor Replace Contactor Diagnostic charge Cleaned condenser coils System is operating *Raining during visit
Largo, FL 33771
On arrival found multiple issues with system. Pressures are reading incorrectly due to improper air flow. Evaporator coil extremely clogged and found issues with ductwork. Due to condition of system we are only able to provide a new system estimate. Will submit quote. Unit is cooling to the best of its ability.
On arrival found multiple issues with system. Pressures are reading incorrectly due to improper air flow. Evaporator coil extremely clogged and found issues with ductwork. Due to condition of system we are only able to provide a new system estimate. Will submit quote. Unit is cooling to the best of its ability.
Justin G.
Justin G. Checked in
On arrival found multiple issues with system. Pressures are reading incorrectly due to improper air flow. Evaporator coil extremely clogged and found issues with ductwork. Due to condition of system we are only able to provide a new system estimate. Will submit quote. Unit is cooling to the best of its ability.
Largo, FL 33771
Upon my inspection, found system #2 air handler secondary drain pan completely full of water. Performed lvl.3 drain cleaning and treatment on system. Drain line is draining properly at this time. Advised client to keep fan in the on position for 2 days and then return to auto afterwards in order to dry the air handler out. If this issue persists, we will need to replace the evaporator coil/primary drain pan under parts warranty if applicable. This primary drain pan could have a crack and letting water escape the unit. 
I noticed there’s evidence of rodent damage in the attic where multiple ducts have holes and one duct connection is separated. 
In the winter time we can address this issue by replacing the damaged ducts. 

Replaced air filter for system. System is cooling with a 20° temperature split at this time.
Upon my inspection, found system #2 air handler secondary drain pan completely full of water. Performed lvl.3 drain cleaning and treatment on system. Drain line is draining properly at this time. Advised client to keep fan in the on position for 2 days and then return to auto afterwards in order to dry the air handler out. If this issue persists, we will need to replace the evaporator coil/primary drain pan under parts warranty if applicable. This primary drain pan could have a crack and letting water escape the unit. 
I noticed there’s evidence of rodent damage in the attic where multiple ducts have holes and one duct connection is separated. 
In the winter time we can address this issue by replacing the damaged ducts. 

Replaced air filter for system. System is cooling with a 20° temperature split at this time.
Michael A.
Michael A. Checked in
Upon my inspection, found system #2 air handler secondary drain pan completely full of water. Performed lvl.3 drain cleaning and treatment on system. Drain line is draining properly at this time. Advised client to keep fan in the on position for 2 days and then return to auto afterwards in order to dry the air handler out. If this issue persists, we will need to replace the evaporator coil/primary drain pan under parts warranty if applicable. This primary drain pan could have a crack and letting water escape the unit. I noticed there’s evidence of rodent damage in the attic where multiple ducts have holes and one duct connection is separated. In the winter time we can address this issue by replacing the damaged ducts. Replaced air filter for system. System is cooling with a 20° temperature split at this time.
Largo, FL 33770
Replace high pressure switch solder on stem of discharge line 
Replace all 7.02 pounds of 410 A 
Replace drier on liquid line
Replace high pressure switch solder on stem of discharge line 
Replace all 7.02 pounds of 410 A 
Replace drier on liquid line
Corbin C.
Corbin C. Checked in
Replace high pressure switch solder on stem of discharge line Replace all 7.02 pounds of 410 A Replace drier on liquid line
Largo, FL 33773
Client states system cannot keep up during the day and it is getting worse. Her husband added refrigerant before he had to leave but they don’t think it solved the issue. Upon my inspection, I found the refrigerant circuit has a restriction causing the unit to not be able to cool efficiently. This system is an off brand and looks to be from 2010. We are not comfortable making the repair on this system given its age and that it’s not a reputable brand. A repair would look like a new TXV, new Liquid line filter drier, and all new refrigerant. 
We are providing an option to replace this system given its current condition and off brand in order to guarantee proper cooling with new warranties. Quote is being sent to clients email.
Client states system cannot keep up during the day and it is getting worse. Her husband added refrigerant before he had to leave but they don’t think it solved the issue. Upon my inspection, I found the refrigerant circuit has a restriction causing the unit to not be able to cool efficiently. This system is an off brand and looks to be from 2010. We are not comfortable making the repair on this system given its age and that it’s not a reputable brand. A repair would look like a new TXV, new Liquid line filter drier, and all new refrigerant. 
We are providing an option to replace this system given its current condition and off brand in order to guarantee proper cooling with new warranties. Quote is being sent to clients email.
Michael A.
Michael A. Checked in
Client states system cannot keep up during the day and it is getting worse. Her husband added refrigerant before he had to leave but they don’t think it solved the issue. Upon my inspection, I found the refrigerant circuit has a restriction causing the unit to not be able to cool efficiently. This system is an off brand and looks to be from 2010. We are not comfortable making the repair on this system given its age and that it’s not a reputable brand. A repair would look like a new TXV, new Liquid line filter drier, and all new refrigerant. We are providing an option to replace this system given its current condition and off brand in order to guarantee proper cooling with new warranties. Quote is being sent to clients email.
Largo, FL 33771
Found completely bad capacitor. Replaced capacitor and started system. Amp draws are good on compressor and fan motor. Rinsed condenser coils complimentary and plugged compressor harness plug back in as it was beginning to fall out from vibrations. 
1 year part warranty on capacitor.
Found completely bad capacitor. Replaced capacitor and started system. Amp draws are good on compressor and fan motor. Rinsed condenser coils complimentary and plugged compressor harness plug back in as it was beginning to fall out from vibrations. 
1 year part warranty on capacitor.
Michael A.
Michael A. Checked in
Found completely bad capacitor. Replaced capacitor and started system. Amp draws are good on compressor and fan motor. Rinsed condenser coils complimentary and plugged compressor harness plug back in as it was beginning to fall out from vibrations. 1 year part warranty on capacitor.
Largo, FL 33770
Upon my inspection, found clogged drain line. This was intermittently turning the system off when it drips the safety float switch. Client says system has not been maintenance since it was installed. Explain that all systems need routine maintenance to prevent issues such as this. Performed a drain cleaning and treatment. System is now cooling. System has a 20° temperature split.
I also found a supply air leak in the existing ductwork Plenum. Made a small patch to this leak complementary. This repair is unrelated to the install as it is existing ductwork. Our connection from the air handler to that duct. Plenum is still sealed properly.

Recommending our Maitenence plan
Upon my inspection, found clogged drain line. This was intermittently turning the system off when it drips the safety float switch. Client says system has not been maintenance since it was installed. Explain that all systems need routine maintenance to prevent issues such as this. Performed a drain cleaning and treatment. System is now cooling. System has a 20° temperature split.
I also found a supply air leak in the existing ductwork Plenum. Made a small patch to this leak complementary. This repair is unrelated to the install as it is existing ductwork. Our connection from the air handler to that duct. Plenum is still sealed properly.

Recommending our Maitenence plan
Michael A.
Michael A. Checked in
Upon my inspection, found clogged drain line. This was intermittently turning the system off when it drips the safety float switch. Client says system has not been maintenance since it was installed. Explain that all systems need routine maintenance to prevent issues such as this. Performed a drain cleaning and treatment. System is now cooling. System has a 20° temperature split. I also found a supply air leak in the existing ductwork Plenum. Made a small patch to this leak complementary. This repair is unrelated to the install as it is existing ductwork. Our connection from the air handler to that duct. Plenum is still sealed properly. Recommending our Maitenence plan
Largo, FL 33770

Contact the Bros You Know Today!