Instant Quote Shop Filters Call Air Bros Book Service

Largo, FL

air-bros-team-with-truck

Largo, FL, Home Comfort Solutions

As a locally owned and operated company, Air Bros is proud to be a part of the Largo community. We understand the challenges that Florida's heat and humidity can bring, and we're dedicated to providing our neighbors with reliable HVAC solutions to keep their homes comfortable year-round. Whether you're just steps from the Gulf or nestled in a quiet neighborhood, you can count on Air Bros for top-notch service and personalized solutions.

Call us at 727-217-6148 or contact us online.

Why Choose Air Bros in Largo?

  • Local Expertise: We're familiar with the unique climate challenges of Largo and the specific needs of its residents.
  • Customer-Focused Approach: Your comfort and satisfaction are our top priorities. We listen to your concerns, answer your questions, and provide tailored solutions that fit your needs and budget.
  • Experienced and Certified Technicians: Our team consists of highly skilled and certified technicians with extensive experience in all aspects of HVAC service. You can trust us to get the job done right.
  • Fast and Reliable Service: We know that HVAC issues can be disruptive. That's why we prioritize prompt and reliable service, offering same-day service for AC emergencies and quick response times for all your HVAC needs.
  • Upfront Pricing: We believe in transparency and honesty. You'll always receive upfront pricing with no hidden costs or surprises.

Comprehensive HVAC Services in Largo, FL

  • Complete Comfort Solutions: We're your one-stop shop for heating and cooling in Largo. Whether you need AC repair on a scorching summer day or a new furnace installed before winter arrives, our expert technicians have you covered. We service all makes and models, ensuring your home stays comfortable no matter the season.
  • Healthy Indoor Air: We go beyond temperature control to ensure the air you breathe is clean and healthy. Our indoor air quality solutions, including dehumidifiers and UV light air purifiers, help control humidity, eliminate allergens, and create a healthier home environment for you and your family.
  • Efficient Airflow: Your ductwork plays a crucial role in your home's comfort and energy efficiency. Our professional ductwork services ensure optimal airflow, prevent energy waste, and improve the overall performance of your HVAC system.

Beyond the Basics

  • Pool Heater Services: Enjoy your pool year-round with our pool heater installation and repair services.
  • Electrical Services: We can handle your electrical needs, including outlet and switch replacements, ceiling fan installations, and whole-house surge protector installations.

Contact Air Bros Today!

We're your trusted HVAC partner in Largo. Contact us today for a free consultation or to schedule a service appointment. Experience the Air Bros difference!

Call us at 727-217-6148 or contact us online.

Recent Jobs and Reviews in Largo, FL

Job Locations and Reviews

Justin G.
Justin G. Checked in
On arrival found unit not cooling due to thermostat not sending proper signal to condenser. Client declined replacement of thermostat and will change themselves. Explained to client our thermostats are covered by warranty through our company. Reset power and unit operates at this time.
Largo, FL 33771
Reason for call:
Member tuneup

Equipment:
2020 trane 2.5 ton 
Vertical in closet 
Condenser on right side of home 

Summary:
Completed tune up to find dirty blower assembly. All equipment is operating within manufacturing specifications. Confirmed pressures, temps, and amps. Checked cap readings. Clean drain line and condensation pump. Flushed both indoor and outdoor coils. 

Solution: 
Recommended uv treatment and cleaning of blower assembly across three repair options.
Reason for call:
Member tuneup

Equipment:
2020 trane 2.5 ton 
Vertical in closet 
Condenser on right side of home 

Summary:
Completed tune up to find dirty blower assembly. All equipment is operating within manufacturing specifications. Confirmed pressures, temps, and amps. Checked cap readings. Clean drain line and condensation pump. Flushed both indoor and outdoor coils. 

Solution: 
Recommended uv treatment and cleaning of blower assembly across three repair options.
Corbin C.
Corbin C. Checked in
Reason for call: Member tuneup Equipment: 2020 trane 2.5 ton Vertical in closet Condenser on right side of home Summary: Completed tune up to find dirty blower assembly. All equipment is operating within manufacturing specifications. Confirmed pressures, temps, and amps. Checked cap readings. Clean drain line and condensation pump. Flushed both indoor and outdoor coils. Solution: Recommended uv treatment and cleaning of blower assembly across three repair options.
Largo, FL 33770
Reason for call:
No cool 

Equipment:
2020 condenser Goodman 
2011 air handler Goodman 

Summary:
Found failed capacitor and buzzing contactor. Replaced both starting components operation was restored to the equipment unit is cooling with a 20 degree split.
Reason for call:
No cool 

Equipment:
2020 condenser Goodman 
2011 air handler Goodman 

Summary:
Found failed capacitor and buzzing contactor. Replaced both starting components operation was restored to the equipment unit is cooling with a 20 degree split.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Equipment: 2020 condenser Goodman 2011 air handler Goodman Summary: Found failed capacitor and buzzing contactor. Replaced both starting components operation was restored to the equipment unit is cooling with a 20 degree split.
Largo, FL 33774
3 Ton American standard system not cooling for conference room. 
Upon my inspection? Found system not cooling due to clogged condensate line and pan. 
Scope of work: 
Condensate Drain cleaning and treatment 
Now cooling with a 20° temperature split

Authorized approval and payment from Lori
Could not get in contact with landlord Ken. Lori called and told Ken that she is approving the work to be done and authorized payment
3 Ton American standard system not cooling for conference room. 
Upon my inspection? Found system not cooling due to clogged condensate line and pan. 
Scope of work: 
Condensate Drain cleaning and treatment 
Now cooling with a 20° temperature split

Authorized approval and payment from Lori
Could not get in contact with landlord Ken. Lori called and told Ken that she is approving the work to be done and authorized payment
Michael A.
Michael A. Checked in
3 Ton American standard system not cooling for conference room. Upon my inspection? Found system not cooling due to clogged condensate line and pan. Scope of work: Condensate Drain cleaning and treatment Now cooling with a 20° temperature split Authorized approval and payment from Lori Could not get in contact with landlord Ken. Lori called and told Ken that she is approving the work to be done and authorized payment
Largo, FL 33773
Upon arrival, I began by checking the temperature differential between the supply and return air and measured a 20°F split, which is within a healthy operating range. I then evaluated the refrigerant circuit and found no signs of leaks, restrictions, or abnormal operating conditions. Refrigerant pressures and system performance were operating as expected.

Next, I inspected the electrical components. All components are operating within their proper amperage ranges, and no shorts, burnouts, or electrical failures were found during testing.

After completing the diagnostic, I determined that the system is functioning properly from a mechanical and electrical standpoint, with no current issues affecting operation. Based on my findings, it appears the drain line condition caused the float switch to activate, which intermittently shut the system off throughout the day.

I performed a drain line treatment to help prevent future blockages and relocated the float switch to a more appropriate p
Upon arrival, I began by checking the temperature differential between the supply and return air and measured a 20°F split, which is within a healthy operating range. I then evaluated the refrigerant circuit and found no signs of leaks, restrictions, or abnormal operating conditions. Refrigerant pressures and system performance were operating as expected.

Next, I inspected the electrical components. All components are operating within their proper amperage ranges, and no shorts, burnouts, or electrical failures were found during testing.

After completing the diagnostic, I determined that the system is functioning properly from a mechanical and electrical standpoint, with no current issues affecting operation. Based on my findings, it appears the drain line condition caused the float switch to activate, which intermittently shut the system off throughout the day.

I performed a drain line treatment to help prevent future blockages and relocated the float switch to a more appropriate p
ihsan m.
ihsan m. Checked in
Upon arrival, I began by checking the temperature differential between the supply and return air and measured a 20°F split, which is within a healthy operating range. I then evaluated the refrigerant circuit and found no signs of leaks, restrictions, or abnormal operating conditions. Refrigerant pressures and system performance were operating as expected. Next, I inspected the electrical components. All components are operating within their proper amperage ranges, and no shorts, burnouts, or electrical failures were found during testing. After completing the diagnostic, I determined that the system is functioning properly from a mechanical and electrical standpoint, with no current issues affecting operation. Based on my findings, it appears the drain line condition caused the float switch to activate, which intermittently shut the system off throughout the day. I performed a drain line treatment to help prevent future blockages and relocated the float switch to a more appropriate p
Largo, FL 33770
Reason for call:
Ac not keeping up 

Equipment:
2025 Lennox 3 ton heat pump 
Vertical in closet 
Condenser out back 

Summary:
Completed diagnosis to confirm refrigerant pressures were low. Gave homeowner option was to charge system sign up on membership for reevaluation. Or do leak search today. She chose to fill up and sign up on membership. System have felt the same since install and her old company informed her the installers who did this job were "fired due to drug use" 

Performed visual leak search today confirmed all braze joints are good and no oil spots in coils. 

Solution:
System has felt the same since install. 
We will top of charge. 
Reevaluate at first maintenance visit
Reason for call:
Ac not keeping up 

Equipment:
2025 Lennox 3 ton heat pump 
Vertical in closet 
Condenser out back 

Summary:
Completed diagnosis to confirm refrigerant pressures were low. Gave homeowner option was to charge system sign up on membership for reevaluation. Or do leak search today. She chose to fill up and sign up on membership. System have felt the same since install and her old company informed her the installers who did this job were "fired due to drug use" 

Performed visual leak search today confirmed all braze joints are good and no oil spots in coils. 

Solution:
System has felt the same since install. 
We will top of charge. 
Reevaluate at first maintenance visit
Corbin C.
Corbin C. Checked in
Reason for call: Ac not keeping up Equipment: 2025 Lennox 3 ton heat pump Vertical in closet Condenser out back Summary: Completed diagnosis to confirm refrigerant pressures were low. Gave homeowner option was to charge system sign up on membership for reevaluation. Or do leak search today. She chose to fill up and sign up on membership. System have felt the same since install and her old company informed her the installers who did this job were "fired due to drug use" Performed visual leak search today confirmed all braze joints are good and no oil spots in coils. Solution: System has felt the same since install. We will top of charge. Reevaluate at first maintenance visit
Largo, FL 33771
Upon arrival, I checked System #1 downstairs and recorded a 23° temperature difference, which is within a healthy operating range. I then checked System #2 and recorded a 20° temperature difference, also within a healthy range.

I inspected the electrical components on both systems, and everything is functioning properly with no issues or concerns at this time. I also performed condenser cleanings, drain line treatments, and full air handler inspections on both systems.

At this time, both systems are operating properly and efficiently. If you have any questions or concerns, please feel free to reach out. Thank you for your business, and have a great day.
Upon arrival, I checked System #1 downstairs and recorded a 23° temperature difference, which is within a healthy operating range. I then checked System #2 and recorded a 20° temperature difference, also within a healthy range.

I inspected the electrical components on both systems, and everything is functioning properly with no issues or concerns at this time. I also performed condenser cleanings, drain line treatments, and full air handler inspections on both systems.

At this time, both systems are operating properly and efficiently. If you have any questions or concerns, please feel free to reach out. Thank you for your business, and have a great day.
ihsan m.
ihsan m. Checked in
Upon arrival, I checked System #1 downstairs and recorded a 23° temperature difference, which is within a healthy operating range. I then checked System #2 and recorded a 20° temperature difference, also within a healthy range. I inspected the electrical components on both systems, and everything is functioning properly with no issues or concerns at this time. I also performed condenser cleanings, drain line treatments, and full air handler inspections on both systems. At this time, both systems are operating properly and efficiently. If you have any questions or concerns, please feel free to reach out. Thank you for your business, and have a great day.
Largo, FL 33778
Install dual capacitor. 
Duct seal in three connections. 
Finish tune up from yesterday.
Install dual capacitor. 
Duct seal in three connections. 
Finish tune up from yesterday.
Corbin C.
Corbin C. Checked in
Install dual capacitor. Duct seal in three connections. Finish tune up from yesterday.
Largo, FL 33777
Reason for call:
Tune up on two systems 

Equipment:
2022 rheem 
Horizontal in second floor closet 
Condenser on left side of home 

2019 Goodman 
Horizontal in first floor attic 
Condenser is on left side of home 

Solution:
Rheem new capacitor
Rheem needs duct seal 
Work was sold for tmr due ti weather 

Summary:
Completed tune ups minus flush drain will handle tmr with repairs. Goodman is in fair condition pressures and temps were spot on 
Rheem isn't running due to shut off on high head pressure confirmed cap is dead will be replaced tmr.
Reason for call:
Tune up on two systems 

Equipment:
2022 rheem 
Horizontal in second floor closet 
Condenser on left side of home 

2019 Goodman 
Horizontal in first floor attic 
Condenser is on left side of home 

Solution:
Rheem new capacitor
Rheem needs duct seal 
Work was sold for tmr due ti weather 

Summary:
Completed tune ups minus flush drain will handle tmr with repairs. Goodman is in fair condition pressures and temps were spot on 
Rheem isn't running due to shut off on high head pressure confirmed cap is dead will be replaced tmr.
Corbin C.
Corbin C. Checked in
Reason for call: Tune up on two systems Equipment: 2022 rheem Horizontal in second floor closet Condenser on left side of home 2019 Goodman Horizontal in first floor attic Condenser is on left side of home Solution: Rheem new capacitor Rheem needs duct seal Work was sold for tmr due ti weather Summary: Completed tune ups minus flush drain will handle tmr with repairs. Goodman is in fair condition pressures and temps were spot on Rheem isn't running due to shut off on high head pressure confirmed cap is dead will be replaced tmr.
Largo, FL 33777
Reason for call:
No cool

Equipment:
2013 package unit 

Summary: 
on arrival found after market fan motor recently installed on condenser. Found capacitor dead. Found disconnect to have poor connection holding out voltage. Replaced both capacitor and disconnect. Operation was restored to equipment. 

Solution:
Replaced disconnect and fan capacitor. Informed homeowner of age and condition of equipment. Signed homeowner up on membership.
Reason for call:
No cool

Equipment:
2013 package unit 

Summary: 
on arrival found after market fan motor recently installed on condenser. Found capacitor dead. Found disconnect to have poor connection holding out voltage. Replaced both capacitor and disconnect. Operation was restored to equipment. 

Solution:
Replaced disconnect and fan capacitor. Informed homeowner of age and condition of equipment. Signed homeowner up on membership.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Equipment: 2013 package unit Summary: on arrival found after market fan motor recently installed on condenser. Found capacitor dead. Found disconnect to have poor connection holding out voltage. Replaced both capacitor and disconnect. Operation was restored to equipment. Solution: Replaced disconnect and fan capacitor. Informed homeowner of age and condition of equipment. Signed homeowner up on membership.
Largo, FL 33778
Replace 150 amp main panel 
Run a new Electrcial chase 
Install new surge protector 
Relabel panel directory
Replace 150 amp main panel 
Run a new Electrcial chase 
Install new surge protector 
Relabel panel directory
Griffin K.
Griffin K. Checked in
Replace 150 amp main panel Run a new Electrcial chase Install new surge protector Relabel panel directory
Largo, FL 33771
Client states system is not cooling. Found the cooling wire not getting voltage from the thermostat to the condenser. Took the thermostat off the wall and jumped out cooling and system turned on. Reconnected the thermostat and tested system and system began running. There may be an intermittent issue with this thermostat. At this time, the system is cooling and the client would like to leave it.

While here, the system is due for a six month Maintenence. 
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.
Client states system is not cooling. Found the cooling wire not getting voltage from the thermostat to the condenser. Took the thermostat off the wall and jumped out cooling and system turned on. Reconnected the thermostat and tested system and system began running. There may be an intermittent issue with this thermostat. At this time, the system is cooling and the client would like to leave it.

While here, the system is due for a six month Maintenence. 
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.
Michael A.
Michael A. Checked in
Client states system is not cooling. Found the cooling wire not getting voltage from the thermostat to the condenser. Took the thermostat off the wall and jumped out cooling and system turned on. Reconnected the thermostat and tested system and system began running. There may be an intermittent issue with this thermostat. At this time, the system is cooling and the client would like to leave it. While here, the system is due for a six month Maintenence. Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.
Largo, FL 33774
Reason for call:
No cool 

Summary:
On arrival found both fans running no compressor. Found dead capacitor. Replaced capacitor confirmed operation or equipment. Found condenser coil and evaporator coil dirty. Homeowner are aware of this and are plan to address it at next maintenance visit. 
Td is 20 upon departure.
Reason for call:
No cool 

Summary:
On arrival found both fans running no compressor. Found dead capacitor. Replaced capacitor confirmed operation or equipment. Found condenser coil and evaporator coil dirty. Homeowner are aware of this and are plan to address it at next maintenance visit. 
Td is 20 upon departure.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: On arrival found both fans running no compressor. Found dead capacitor. Replaced capacitor confirmed operation or equipment. Found condenser coil and evaporator coil dirty. Homeowner are aware of this and are plan to address it at next maintenance visit. Td is 20 upon departure.
Largo, FL 33771
Diagnostic 
-clogged drain line and pan caused system to overflow and damage ceiling. 
-no primary overflow safety switch 
-unit had backwards pitch 

Solutions 
-cleared drain line and drain pan (verified proper drainage)
-pitched air handler Wants
-added pan tabs to help with buildup 
-installed primary safety overflow 

Next Step Solutions 
-remove water damaged return plenum 
-install new return plenum and connect flex ducting 

Verified system operations. No further issues
Diagnostic 
-clogged drain line and pan caused system to overflow and damage ceiling. 
-no primary overflow safety switch 
-unit had backwards pitch 

Solutions 
-cleared drain line and drain pan (verified proper drainage)
-pitched air handler Wants
-added pan tabs to help with buildup 
-installed primary safety overflow 

Next Step Solutions 
-remove water damaged return plenum 
-install new return plenum and connect flex ducting 

Verified system operations. No further issues
Nathan A.
Nathan A. Checked in
Diagnostic -clogged drain line and pan caused system to overflow and damage ceiling. -no primary overflow safety switch -unit had backwards pitch Solutions -cleared drain line and drain pan (verified proper drainage) -pitched air handler Wants -added pan tabs to help with buildup -installed primary safety overflow Next Step Solutions -remove water damaged return plenum -install new return plenum and connect flex ducting Verified system operations. No further issues
Largo, FL 33774
Backed up drain line, home owner will clear. Checked pressures and temp splits. Checked starting components. Debris accumulating on back side of air handler coils.
Backed up drain line, home owner will clear. Checked pressures and temp splits. Checked starting components. Debris accumulating on back side of air handler coils.
Nathan A.
Nathan A. Checked in
Backed up drain line, home owner will clear. Checked pressures and temp splits. Checked starting components. Debris accumulating on back side of air handler coils.
Largo, FL 33770
On arrival found ICP rooftop package unit not cooling due to bad blower motor. Replaced part. Start and test. Pressures good. Electrical good. Unit cooling properly at this time.
On arrival found ICP rooftop package unit not cooling due to bad blower motor. Replaced part. Start and test. Pressures good. Electrical good. Unit cooling properly at this time.
Justin G.
Justin G. Checked in
On arrival found ICP rooftop package unit not cooling due to bad blower motor. Replaced part. Start and test. Pressures good. Electrical good. Unit cooling properly at this time.
Largo, FL 33773
Michael A.
Michael A. Checked in
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. System has no safety float switch. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is not within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. Replaced capacitor. Found very dirty blower wheel. Removed blower assembly and deep cleaned/sanitized. Send membership info to client and if they move forward by end of day April 6th 2026 we will refund 10% of invoice.
Largo, FL 33774
Full System Tuneup 

Full system tuneup 

Wiped Down Air Handler 

Checked temperature splits 

Verified IAQ Operation 

Tested Safety Overflow Switch 

Inspected Air Handler Coils 

Inspected Blower Wheel & Assembly 

Checked cap mfd 

Checked contactor 

Inspected wiring/Tightened Connections 

Compressor amps 

Motor amps 

Cleaned Service Panel

Cleared drain line and pan 

Added pan tab to help with buildup 

Checked refrigerant pressures 

Checked blower amps 

Checked filter 

Thermostat operations 

Checked  cooling 

Unit is operating at this time 

Recommendations 
-replace failed capacitor
-chemically clean outdoor coils 

Went over these repairs with home owner and completed work 

Further Notes
-air handler coils starting to rust 
-outdoor filter drier start to corrode and rust 
-outdoor insulation failing
Full System Tuneup 

Full system tuneup 

Wiped Down Air Handler 

Checked temperature splits 

Verified IAQ Operation 

Tested Safety Overflow Switch 

Inspected Air Handler Coils 

Inspected Blower Wheel & Assembly 

Checked cap mfd 

Checked contactor 

Inspected wiring/Tightened Connections 

Compressor amps 

Motor amps 

Cleaned Service Panel

Cleared drain line and pan 

Added pan tab to help with buildup 

Checked refrigerant pressures 

Checked blower amps 

Checked filter 

Thermostat operations 

Checked  cooling 

Unit is operating at this time 

Recommendations 
-replace failed capacitor
-chemically clean outdoor coils 

Went over these repairs with home owner and completed work 

Further Notes
-air handler coils starting to rust 
-outdoor filter drier start to corrode and rust 
-outdoor insulation failing
Nathan A.
Nathan A. Checked in
Full System Tuneup Full system tuneup Wiped Down Air Handler Checked temperature splits Verified IAQ Operation Tested Safety Overflow Switch Inspected Air Handler Coils Inspected Blower Wheel & Assembly Checked cap mfd Checked contactor Inspected wiring/Tightened Connections Compressor amps Motor amps Cleaned Service Panel Cleared drain line and pan Added pan tab to help with buildup Checked refrigerant pressures Checked blower amps Checked filter Thermostat operations Checked cooling Unit is operating at this time Recommendations -replace failed capacitor -chemically clean outdoor coils Went over these repairs with home owner and completed work Further Notes -air handler coils starting to rust -outdoor filter drier start to corrode and rust -outdoor insulation failing
Largo, FL 33771
Scope of work:
- Disconnect condenser unit
- Raise condenser on wall mount brackets
- Extend low voltage to condenser
- Extend high voltage electrical to condenser from disconnect
- Extend copper lineset
- Install new UV rated insulation
- Hurricane strap unit to wall mount brackets
*No guarantee of system working due to system age being 16 years old*

After completion, home still does not have power. Told Leah to give us a call if there’s any issues in the future once power is restored.
Scope of work:
- Disconnect condenser unit
- Raise condenser on wall mount brackets
- Extend low voltage to condenser
- Extend high voltage electrical to condenser from disconnect
- Extend copper lineset
- Install new UV rated insulation
- Hurricane strap unit to wall mount brackets
*No guarantee of system working due to system age being 16 years old*

After completion, home still does not have power. Told Leah to give us a call if there’s any issues in the future once power is restored.
Justin G.
Justin G. Checked in
Scope of work: - Disconnect condenser unit - Raise condenser on wall mount brackets - Extend low voltage to condenser - Extend high voltage electrical to condenser from disconnect - Extend copper lineset - Install new UV rated insulation - Hurricane strap unit to wall mount brackets *No guarantee of system working due to system age being 16 years old* After completion, home still does not have power. Told Leah to give us a call if there’s any issues in the future once power is restored.
Largo, FL 33774
Largo, FL - Install surge protection device on the panel 

Inspected meter can and panels and did not smell or see any thing burned or any sign of Electrcial damage
Griffin K.
Griffin K. Checked in
Install surge protection device on the panel Inspected meter can and panels and did not smell or see any thing burned or any sign of Electrcial damage
Largo, FL 33778
Upon my inspection, found system was not wired properly for heat pump condenser. Thermostat is too small for client to view numbers. Found drain line not properly insulated and a connection not glued properly causing condensation to drip onto garage floor. 
Made all necessary repairs. Set up thermostat with clients phone. 
Verified heating and cooling functions. 

Performed first system Maitenence. Cleaned and treated drain line and primary drain pan. Checked capacitor and amp draws on motors and compressor. Cleaned condenser coils.

Client is interested in bigger back up heating strips however that would require increasing the wire size and breaker from the main electrical panel. System is heating just fine at this time. 

Supply plenum and return plenum are not mastic sealed at this time but are not leaking air.
Upon my inspection, found system was not wired properly for heat pump condenser. Thermostat is too small for client to view numbers. Found drain line not properly insulated and a connection not glued properly causing condensation to drip onto garage floor. 
Made all necessary repairs. Set up thermostat with clients phone. 
Verified heating and cooling functions. 

Performed first system Maitenence. Cleaned and treated drain line and primary drain pan. Checked capacitor and amp draws on motors and compressor. Cleaned condenser coils.

Client is interested in bigger back up heating strips however that would require increasing the wire size and breaker from the main electrical panel. System is heating just fine at this time. 

Supply plenum and return plenum are not mastic sealed at this time but are not leaking air.
Michael A.
Michael A. Checked in
Upon my inspection, found system was not wired properly for heat pump condenser. Thermostat is too small for client to view numbers. Found drain line not properly insulated and a connection not glued properly causing condensation to drip onto garage floor. Made all necessary repairs. Set up thermostat with clients phone. Verified heating and cooling functions. Performed first system Maitenence. Cleaned and treated drain line and primary drain pan. Checked capacitor and amp draws on motors and compressor. Cleaned condenser coils. Client is interested in bigger back up heating strips however that would require increasing the wire size and breaker from the main electrical panel. System is heating just fine at this time. Supply plenum and return plenum are not mastic sealed at this time but are not leaking air.
Largo, FL 33771
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.
Michael A.
Michael A. Checked in
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.
Largo, FL 33774
25 year old system in poor condition. Client would like a quote for new system. Quote sent to client. Refund $95 with install
25 year old system in poor condition. Client would like a quote for new system. Quote sent to client. Refund $95 with install
Michael A.
Michael A. Checked in
25 year old system in poor condition. Client would like a quote for new system. Quote sent to client. Refund $95 with install
Largo, FL 33771
Upon my inspection, found pool heater capacitor is bad. Replaced capacitor and checked pressures. Pressures are good. System turned off again on high refrig alarm code. Found pool flow pressure was too low. Adjusted valves to create more pressure for heat exchange. System is functioning properly at this time.
Upon my inspection, found pool heater capacitor is bad. Replaced capacitor and checked pressures. Pressures are good. System turned off again on high refrig alarm code. Found pool flow pressure was too low. Adjusted valves to create more pressure for heat exchange. System is functioning properly at this time.
Michael A.
Michael A. Checked in
Upon my inspection, found pool heater capacitor is bad. Replaced capacitor and checked pressures. Pressures are good. System turned off again on high refrig alarm code. Found pool flow pressure was too low. Adjusted valves to create more pressure for heat exchange. System is functioning properly at this time.
Largo, FL 33771
Ruud 3.5 ton heat pump
15 seer heat pump
10 year parts warranty
5 year labor warranty
-Two hurricane pads
-Tiedowns
-Strap pads to each other no cinders 
-Replace breakers as needed
-Thermostat WiFi
-Coffin box
-Seal to existing plenums 
-Safety switch
-Flush drain
-Reinsulate all exposed piping 
-Financing 0% 18months avail
-3% cash discount
Ruud 3.5 ton heat pump
15 seer heat pump
10 year parts warranty
5 year labor warranty
-Two hurricane pads
-Tiedowns
-Strap pads to each other no cinders 
-Replace breakers as needed
-Thermostat WiFi
-Coffin box
-Seal to existing plenums 
-Safety switch
-Flush drain
-Reinsulate all exposed piping 
-Financing 0% 18months avail
-3% cash discount
Martin W.
Martin W. Checked in
Ruud 3.5 ton heat pump 15 seer heat pump 10 year parts warranty 5 year labor warranty -Two hurricane pads -Tiedowns -Strap pads to each other no cinders -Replace breakers as needed -Thermostat WiFi -Coffin box -Seal to existing plenums -Safety switch -Flush drain -Reinsulate all exposed piping -Financing 0% 18months avail -3% cash discount
Largo, FL 33773

Contact the Bros You Know Today!

Schedule Service Online
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at 727-217-6148 .

By pressing Submit I agree to receive phone, email, or text messages from Air Bros Air Conditioning & Heating to the provided mobile number and also agree to the Air Bros Air Conditioning & Heating terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next