Instant Quote Shop Filters Call Air Bros

Largo, FL

air-bros-team-with-truck

Largo, FL, Home Comfort Solutions

As a locally owned and operated company, Air Bros is proud to be a part of the Largo community. We understand the challenges that Florida's heat and humidity can bring, and we're dedicated to providing our neighbors with reliable HVAC solutions to keep their homes comfortable year-round. Whether you're just steps from the Gulf or nestled in a quiet neighborhood, you can count on Air Bros for top-notch service and personalized solutions.

Call us at 727-217-6148 or contact us online.

Why Choose Air Bros in Largo?

  • Local Expertise: We're familiar with the unique climate challenges of Largo and the specific needs of its residents.
  • Customer-Focused Approach: Your comfort and satisfaction are our top priorities. We listen to your concerns, answer your questions, and provide tailored solutions that fit your needs and budget.
  • Experienced and Certified Technicians: Our team consists of highly skilled and certified technicians with extensive experience in all aspects of HVAC service. You can trust us to get the job done right.
  • Fast and Reliable Service: We know that HVAC issues can be disruptive. That's why we prioritize prompt and reliable service, offering same-day service for AC emergencies and quick response times for all your HVAC needs.
  • Upfront Pricing: We believe in transparency and honesty. You'll always receive upfront pricing with no hidden costs or surprises.

Comprehensive HVAC Services in Largo, FL

  • Complete Comfort Solutions: We're your one-stop shop for heating and cooling in Largo. Whether you need AC repair on a scorching summer day or a new furnace installed before winter arrives, our expert technicians have you covered. We service all makes and models, ensuring your home stays comfortable no matter the season.
  • Healthy Indoor Air: We go beyond temperature control to ensure the air you breathe is clean and healthy. Our indoor air quality solutions, including dehumidifiers and UV light air purifiers, help control humidity, eliminate allergens, and create a healthier home environment for you and your family.
  • Efficient Airflow: Your ductwork plays a crucial role in your home's comfort and energy efficiency. Our professional ductwork services ensure optimal airflow, prevent energy waste, and improve the overall performance of your HVAC system.

Beyond the Basics

  • Pool Heater Services: Enjoy your pool year-round with our pool heater installation and repair services.
  • Electrical Services: We can handle your electrical needs, including outlet and switch replacements, ceiling fan installations, and whole-house surge protector installations.

Contact Air Bros Today!

We're your trusted HVAC partner in Largo. Contact us today for a free consultation or to schedule a service appointment. Experience the Air Bros difference!

Call us at 727-217-6148 or contact us online.

Recent Jobs and Reviews in Largo, FL

Largo, FL at a glance

Air Bros Air Conditioning & Electrical has completed 25 jobs in Largo, FL between July 2026 and September 2026.

The most recent job was on September 5, 2026.

Air Bros Air Conditioning & Electrical has completed 106 jobs in Largo, FL in the last 12 months. The first job there was in February 2025.

Job Locations and Reviews

Michael A.
Michael A. Checked in
Upon my inspection, found system turned off due to clogged drain line and tripped to primary safety float switch. Performed a drain cleaning and treatment. Started system. Client signed up for maintenance plan today. Performed first maintenance today. System is cooling with a 19° temperature split, good amp draws, we clean the condenser coils, found that the capacitor is out of tolerance range. Replaced capacitor today. System is cooling and draining properly at this time Inside the air handler, we found a heavy amount of bacterial growth. I showed the client and the client wanted a quote for cleaning and the installation of a UV air purifier. Sending a quote for cleanings and UV protection.
Largo, FL 33778
Found system has a clogged drain line. Performed a drain cleaning and treatment. Drain line was very clogged with a lack of maintenance. If drain line needs to be cleaned again too soon, we recommend a level three treatment.
System is cooling with a 20° temperature split at this time.

Replaced air filter with client supplied
Found system has a clogged drain line. Performed a drain cleaning and treatment. Drain line was very clogged with a lack of maintenance. If drain line needs to be cleaned again too soon, we recommend a level three treatment.
System is cooling with a 20° temperature split at this time.

Replaced air filter with client supplied
Michael A.
Michael A. Checked in
Found system has a clogged drain line. Performed a drain cleaning and treatment. Drain line was very clogged with a lack of maintenance. If drain line needs to be cleaned again too soon, we recommend a level three treatment. System is cooling with a 20° temperature split at this time. Replaced air filter with client supplied
Largo, FL 33774
Mitsubishi 12k heat pump
12 year parts warranty
12 year labor warranty
-Electric run from panel
-New breaker homeline
-Service disconnect
-Hurricane pad
-Hurricane tiedowns
-Insulated line set
-Line cover
-Comm wire
-Seal penetrations
-100% satisfaction guarantee
Mitsubishi 12k heat pump
12 year parts warranty
12 year labor warranty
-Electric run from panel
-New breaker homeline
-Service disconnect
-Hurricane pad
-Hurricane tiedowns
-Insulated line set
-Line cover
-Comm wire
-Seal penetrations
-100% satisfaction guarantee
Kyle K.
Kyle K. Checked in
Mitsubishi 12k heat pump 12 year parts warranty 12 year labor warranty -Electric run from panel -New breaker homeline -Service disconnect -Hurricane pad -Hurricane tiedowns -Insulated line set -Line cover -Comm wire -Seal penetrations -100% satisfaction guarantee
Largo, FL 33774
Install new 2.5 ton package unit Goodman
Install new package unit pad 
Install new thermostat 
Custom fabrication of duct work to unit 
New custom built duct work cover 
Reuse electrical 
cash
Install new 2.5 ton package unit Goodman
Install new package unit pad 
Install new thermostat 
Custom fabrication of duct work to unit 
New custom built duct work cover 
Reuse electrical 
cash
Ricky O.
Ricky O. Checked in
Install new 2.5 ton package unit Goodman Install new package unit pad Install new thermostat Custom fabrication of duct work to unit New custom built duct work cover Reuse electrical cash
Largo, FL 33771
Replace 20 foot 10 in 
Replace 15 foot of 4 in 

Completed repair. All duct work is sealed and strapped in guest apt.
Replace 20 foot 10 in 
Replace 15 foot of 4 in 

Completed repair. All duct work is sealed and strapped in guest apt.
Corbin C.
Corbin C. Checked in
Replace 20 foot 10 in Replace 15 foot of 4 in Completed repair. All duct work is sealed and strapped in guest apt.
Largo, FL 33777
Upon my inspection, found air handler located in garage is not sealed properly. Observed with smoke device showing that the supply plenum is leaking air and the return side is allowing for garage air to enter the home. Also found the electrical conduit snapped in half and client would like it replaced. 
Quote sent for these repairs on the system. 

Air handler is sweating inside the garage. The garage has no humidity control or ventilation. We recommend a standalone dehumidifier set up right next to the air handler to aid in dehumidifying the garage. 
Client does not want a mini split installed. 


In the attic, there are no ridge vents. Attic does not have adequate ventilation causing supply ducts to sweat. We recommend installing a solar attic fan. Quote sent for attic fan. 

System is cooling with a 20° temp split at this time. 
Primary safety float switch is operating properly.
Upon my inspection, found air handler located in garage is not sealed properly. Observed with smoke device showing that the supply plenum is leaking air and the return side is allowing for garage air to enter the home. Also found the electrical conduit snapped in half and client would like it replaced. 
Quote sent for these repairs on the system. 

Air handler is sweating inside the garage. The garage has no humidity control or ventilation. We recommend a standalone dehumidifier set up right next to the air handler to aid in dehumidifying the garage. 
Client does not want a mini split installed. 


In the attic, there are no ridge vents. Attic does not have adequate ventilation causing supply ducts to sweat. We recommend installing a solar attic fan. Quote sent for attic fan. 

System is cooling with a 20° temp split at this time. 
Primary safety float switch is operating properly.
Michael A.
Michael A. Checked in
Upon my inspection, found air handler located in garage is not sealed properly. Observed with smoke device showing that the supply plenum is leaking air and the return side is allowing for garage air to enter the home. Also found the electrical conduit snapped in half and client would like it replaced. Quote sent for these repairs on the system. Air handler is sweating inside the garage. The garage has no humidity control or ventilation. We recommend a standalone dehumidifier set up right next to the air handler to aid in dehumidifying the garage. Client does not want a mini split installed. In the attic, there are no ridge vents. Attic does not have adequate ventilation causing supply ducts to sweat. We recommend installing a solar attic fan. Quote sent for attic fan. System is cooling with a 20° temp split at this time. Primary safety float switch is operating properly.
Largo, FL 33773
Sante Fe 70 dehumidifier 
Aux pans
Safety switches
Hanging kit
New drains and insulate
Electrical
Triangle platform
6 year parts warranty 
3 year labor warranty 
Tax and labor included 
Price include 2 dehumidifiers installed
Check price only
Sante Fe 70 dehumidifier 
Aux pans
Safety switches
Hanging kit
New drains and insulate
Electrical
Triangle platform
6 year parts warranty 
3 year labor warranty 
Tax and labor included 
Price include 2 dehumidifiers installed
Check price only
Justin G.
Justin G. Checked in
Sante Fe 70 dehumidifier Aux pans Safety switches Hanging kit New drains and insulate Electrical Triangle platform 6 year parts warranty 3 year labor warranty Tax and labor included Price include 2 dehumidifiers installed Check price only
Largo, FL 33778
Upon my inspection, found thermostat has a humid stack connected to it that was not set properly. The humid thermostat was not allowing the system to turn on. I set the humid stat to the on position and the system turns on and turns off with the thermostat only now. System is cooling with a 20° temperature split. Looked over the condenser and found no apparent issues at this time.
Recommended that Client set up a maintenance soon.
Upon my inspection, found thermostat has a humid stack connected to it that was not set properly. The humid thermostat was not allowing the system to turn on. I set the humid stat to the on position and the system turns on and turns off with the thermostat only now. System is cooling with a 20° temperature split. Looked over the condenser and found no apparent issues at this time.
Recommended that Client set up a maintenance soon.
Michael A.
Michael A. Checked in
Upon my inspection, found thermostat has a humid stack connected to it that was not set properly. The humid thermostat was not allowing the system to turn on. I set the humid stat to the on position and the system turns on and turns off with the thermostat only now. System is cooling with a 20° temperature split. Looked over the condenser and found no apparent issues at this time. Recommended that Client set up a maintenance soon.
Largo, FL 33774
Reason for call:
No cool 

Summary:
Found failed capacitor. Found buzzing contactor. 
Restored operation to equipment. 
Homeowner is not Intrested in maintenance plan. 
Unit cooling by 18 degrees 

Replace capacitor and contactor to restore operation to equipment
Reason for call:
No cool 

Summary:
Found failed capacitor. Found buzzing contactor. 
Restored operation to equipment. 
Homeowner is not Intrested in maintenance plan. 
Unit cooling by 18 degrees 

Replace capacitor and contactor to restore operation to equipment
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: Found failed capacitor. Found buzzing contactor. Restored operation to equipment. Homeowner is not Intrested in maintenance plan. Unit cooling by 18 degrees Replace capacitor and contactor to restore operation to equipment
Largo, FL 33771
Upon arrival, I began by inspecting the outdoor condenser. I found that the compressor was running, but the condenser fan motor was not operating. Further diagnostic testing determined that the capacitor had failed.

I replaced the faulty capacitor and inspected the contactor to ensure proper operation and prevent potential premature failure. After completing the repair, I verified that the system was operating properly.

I also signed the homeowners up for our maintenance plan, which will help keep the system operating efficiently and allow us to identify potential issues before they become major repairs.

If you have any questions or concerns, please feel free to reach out. Thank you for your business, and have a great day!
Upon arrival, I began by inspecting the outdoor condenser. I found that the compressor was running, but the condenser fan motor was not operating. Further diagnostic testing determined that the capacitor had failed.

I replaced the faulty capacitor and inspected the contactor to ensure proper operation and prevent potential premature failure. After completing the repair, I verified that the system was operating properly.

I also signed the homeowners up for our maintenance plan, which will help keep the system operating efficiently and allow us to identify potential issues before they become major repairs.

If you have any questions or concerns, please feel free to reach out. Thank you for your business, and have a great day!
Ace m.
Ace m. Checked in
Upon arrival, I began by inspecting the outdoor condenser. I found that the compressor was running, but the condenser fan motor was not operating. Further diagnostic testing determined that the capacitor had failed. I replaced the faulty capacitor and inspected the contactor to ensure proper operation and prevent potential premature failure. After completing the repair, I verified that the system was operating properly. I also signed the homeowners up for our maintenance plan, which will help keep the system operating efficiently and allow us to identify potential issues before they become major repairs. If you have any questions or concerns, please feel free to reach out. Thank you for your business, and have a great day!
Largo, FL 33773
Upon arrival, the workers at the home explained that the system had been struggling to maintain a temperature below 74°F during the daytime. I performed a complete diagnostic of the system and found a 19°F temperature split, indicating the system is cooling properly. The refrigerant cycle was operating within a healthy range, and all electrical components were functioning properly with no signs of excessive amperage or components struggling under load.

Based on the diagnostic findings and further discussion, it appears the primary concern is related to the outdoor conditions. With outdoor temperatures reaching approximately 93°F, it is not always realistic for the system to maintain temperatures below 74°F during the hottest part of the day, particularly depending on the home’s insulation, ductwork, windows, occupancy, and overall heat load.

While the system was running during the visit, the indoor temperature dropped an additional degree to 73°F, confirming that the system is active
Upon arrival, the workers at the home explained that the system had been struggling to maintain a temperature below 74°F during the daytime. I performed a complete diagnostic of the system and found a 19°F temperature split, indicating the system is cooling properly. The refrigerant cycle was operating within a healthy range, and all electrical components were functioning properly with no signs of excessive amperage or components struggling under load.

Based on the diagnostic findings and further discussion, it appears the primary concern is related to the outdoor conditions. With outdoor temperatures reaching approximately 93°F, it is not always realistic for the system to maintain temperatures below 74°F during the hottest part of the day, particularly depending on the home’s insulation, ductwork, windows, occupancy, and overall heat load.

While the system was running during the visit, the indoor temperature dropped an additional degree to 73°F, confirming that the system is active
Ace m.
Ace m. Checked in
Upon arrival, the workers at the home explained that the system had been struggling to maintain a temperature below 74°F during the daytime. I performed a complete diagnostic of the system and found a 19°F temperature split, indicating the system is cooling properly. The refrigerant cycle was operating within a healthy range, and all electrical components were functioning properly with no signs of excessive amperage or components struggling under load. Based on the diagnostic findings and further discussion, it appears the primary concern is related to the outdoor conditions. With outdoor temperatures reaching approximately 93°F, it is not always realistic for the system to maintain temperatures below 74°F during the hottest part of the day, particularly depending on the home’s insulation, ductwork, windows, occupancy, and overall heat load. While the system was running during the visit, the indoor temperature dropped an additional degree to 73°F, confirming that the system is active
Largo, FL 33778
Ricky O.
Ricky O. Checked in
System is 20 years old and low on refrigerant. Talked to landlord who lives out of state. He wants me to send him a quote
Largo, FL 33774
Ricky O.
Ricky O. Checked in
Replaced warranty cap
Largo, FL 33771
Replace evaporator coil under parts warranty
Replace filter dryer
Vacuum system
Critically charge system


Competed repair proper operation was restored to the equipment.
Replace evaporator coil under parts warranty
Replace filter dryer
Vacuum system
Critically charge system


Competed repair proper operation was restored to the equipment.
Corbin C.
Corbin C. Checked in
Replace evaporator coil under parts warranty Replace filter dryer Vacuum system Critically charge system Competed repair proper operation was restored to the equipment.
Largo, FL 33771
Performed tune up on system. 
Cleaned and treated drain line. Cleaned condenser coils. Performed full inspection on system. 
Amp draws are good. 
Primary drain pan is holding excess water and it is escaping the pan and saturating the bottom of the furnace/air handler. This is due to the evaporator coils being improperly installed and not properly leveled. 
Blower wheel is dirty and impacted with bacterial growth
Found media filter in air handler that hasn’t been changed in a long time and client was unaware of its existence. Removed and made sure there was a filter in the ceiling. 
Drain line is missing insulation and is sweating with condensation as it is exposed to the hot garage air. 
At the condenser I found a weak capacitor and contactar. Replaced these components while here. 

Let client know system is 13 years old and not in the best condition. 
Sending quote for full replacement with new warranties. 
System is cooling at this time with a 20° temperature split. 
System will cont
Performed tune up on system. 
Cleaned and treated drain line. Cleaned condenser coils. Performed full inspection on system. 
Amp draws are good. 
Primary drain pan is holding excess water and it is escaping the pan and saturating the bottom of the furnace/air handler. This is due to the evaporator coils being improperly installed and not properly leveled. 
Blower wheel is dirty and impacted with bacterial growth
Found media filter in air handler that hasn’t been changed in a long time and client was unaware of its existence. Removed and made sure there was a filter in the ceiling. 
Drain line is missing insulation and is sweating with condensation as it is exposed to the hot garage air. 
At the condenser I found a weak capacitor and contactar. Replaced these components while here. 

Let client know system is 13 years old and not in the best condition. 
Sending quote for full replacement with new warranties. 
System is cooling at this time with a 20° temperature split. 
System will cont
Michael A.
Michael A. Checked in
Performed tune up on system. Cleaned and treated drain line. Cleaned condenser coils. Performed full inspection on system. Amp draws are good. Primary drain pan is holding excess water and it is escaping the pan and saturating the bottom of the furnace/air handler. This is due to the evaporator coils being improperly installed and not properly leveled. Blower wheel is dirty and impacted with bacterial growth Found media filter in air handler that hasn’t been changed in a long time and client was unaware of its existence. Removed and made sure there was a filter in the ceiling. Drain line is missing insulation and is sweating with condensation as it is exposed to the hot garage air. At the condenser I found a weak capacitor and contactar. Replaced these components while here. Let client know system is 13 years old and not in the best condition. Sending quote for full replacement with new warranties. System is cooling at this time with a 20° temperature split. System will cont
Largo, FL 33774
Michael A.
Michael A. Checked in
Upon my inspection, found system not cooling due to a seized up condenser fan motor and a failed start/run capacitor. Thermostat inside is faulty and not showing the display properly. Replaced the condenser fan motor, replaced the capacitor, replaced the thermostat and programmed. Made sure all connections are tight. Started system and system is now cooling with a 20° temperature split. System is operating within manufacture specifications at this time. Inspected evaporator coils and found dirty coils. I let the client know that this will affect efficiency and make the indoor blower motor work harder. Compressor is pulling 11.4 amps with a max rating of 14.1 Waived $95 service fee with repair. 1 year warranty on condenser fan motor 1 year warranty on thermostat 1 year warranty on capacitor
Largo, FL 33770
Upon my inspection, found a severely clogged drain line. Performed drain cleaning on system. System is now draining and cooling with a 20° temperature split. I let the client know that the drain line is not perfectly clean as there is built-up almost cemented debris in the drain line. That is very difficult to remove. If drain line issues persist in the future, I recommended we replace the drain line for guaranteed solution.
Client signed up for Maitenence plan today. Discounts applied and system is cooling at this time.
Upon my inspection, found a severely clogged drain line. Performed drain cleaning on system. System is now draining and cooling with a 20° temperature split. I let the client know that the drain line is not perfectly clean as there is built-up almost cemented debris in the drain line. That is very difficult to remove. If drain line issues persist in the future, I recommended we replace the drain line for guaranteed solution.
Client signed up for Maitenence plan today. Discounts applied and system is cooling at this time.
Michael A.
Michael A. Checked in
Upon my inspection, found a severely clogged drain line. Performed drain cleaning on system. System is now draining and cooling with a 20° temperature split. I let the client know that the drain line is not perfectly clean as there is built-up almost cemented debris in the drain line. That is very difficult to remove. If drain line issues persist in the future, I recommended we replace the drain line for guaranteed solution. Client signed up for Maitenence plan today. Discounts applied and system is cooling at this time.
Largo, FL 33773
Reason for call:
Precision tune up 

Equipment:
2014 package unit Goodman 

Summary:
Completed tune up to find operation of equipment within manufacturing specifications. Found proper temperature. Found proper amp draws. Flushed drain line, pan and coils. Found both the blower capacitor and the main dual capacitor weak. Informed homeowner of age and caps. He decided to replace capacitors. And try and get another couple years out of equipment. 

Solution:
10 mfd for blower 
45/5 mfd for Condneser side of unit
Reason for call:
Precision tune up 

Equipment:
2014 package unit Goodman 

Summary:
Completed tune up to find operation of equipment within manufacturing specifications. Found proper temperature. Found proper amp draws. Flushed drain line, pan and coils. Found both the blower capacitor and the main dual capacitor weak. Informed homeowner of age and caps. He decided to replace capacitors. And try and get another couple years out of equipment. 

Solution:
10 mfd for blower 
45/5 mfd for Condneser side of unit
Corbin C.
Corbin C. Checked in
Reason for call: Precision tune up Equipment: 2014 package unit Goodman Summary: Completed tune up to find operation of equipment within manufacturing specifications. Found proper temperature. Found proper amp draws. Flushed drain line, pan and coils. Found both the blower capacitor and the main dual capacitor weak. Informed homeowner of age and caps. He decided to replace capacitors. And try and get another couple years out of equipment. Solution: 10 mfd for blower 45/5 mfd for Condneser side of unit
Largo, FL 33771
On arrival found unit not cooling due to clogged drain. Cleared pan and drain, added chemical to pan. Performed first maintenance. Electrical checked good. Pressures good. Rinsed outdoor condenser coil. Filter checked and was changed. Unit cooling at this time. 
During clearing of drain, observed line is restricted. Recommend to perform chemical cleaning to help line drain better.
On arrival found unit not cooling due to clogged drain. Cleared pan and drain, added chemical to pan. Performed first maintenance. Electrical checked good. Pressures good. Rinsed outdoor condenser coil. Filter checked and was changed. Unit cooling at this time. 
During clearing of drain, observed line is restricted. Recommend to perform chemical cleaning to help line drain better.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to clogged drain. Cleared pan and drain, added chemical to pan. Performed first maintenance. Electrical checked good. Pressures good. Rinsed outdoor condenser coil. Filter checked and was changed. Unit cooling at this time. During clearing of drain, observed line is restricted. Recommend to perform chemical cleaning to help line drain better.
Largo, FL 33773
Scope of Work
-replace rusted drain pan 
-pitch air handler properly 
-install primary safety overflow switch 
-replace p trap 
-clean drain pan and add pan solution
-clear drain line 
-glue with pvc joints and air handler connections 
-prime drain and trap 

Verified system is draining
Scope of Work
-replace rusted drain pan 
-pitch air handler properly 
-install primary safety overflow switch 
-replace p trap 
-clean drain pan and add pan solution
-clear drain line 
-glue with pvc joints and air handler connections 
-prime drain and trap 

Verified system is draining
Nathan A.
Nathan A. Checked in
Scope of Work -replace rusted drain pan -pitch air handler properly -install primary safety overflow switch -replace p trap -clean drain pan and add pan solution -clear drain line -glue with pvc joints and air handler connections -prime drain and trap Verified system is draining
Largo, FL 33774
Compressor shorted to ground
Compressor shorted to ground
Nathan A.
Nathan A. Checked in
Compressor shorted to ground
Largo, FL 33774
Upon arrival, the homeowner stated that water was leaking through the ceiling and had noticed water around the air handler. After performing a diagnostic, I found that the condensate drain line was clogged, causing water to back up into the system and overflow onto the floor, which resulted in the ceiling leak.

I completed a full system inspection and found a 20°F temperature difference between the supply and return, healthy refrigerant pressures, and all electrical components operating properly.

I performed a condensate drain line treatment and verified that the drain line was flowing and draining properly after the service. At this time, the system is operating as designed.

If you have any questions, please don’t hesitate to reach out. Thank you for your business, and have a great day!
Upon arrival, the homeowner stated that water was leaking through the ceiling and had noticed water around the air handler. After performing a diagnostic, I found that the condensate drain line was clogged, causing water to back up into the system and overflow onto the floor, which resulted in the ceiling leak.

I completed a full system inspection and found a 20°F temperature difference between the supply and return, healthy refrigerant pressures, and all electrical components operating properly.

I performed a condensate drain line treatment and verified that the drain line was flowing and draining properly after the service. At this time, the system is operating as designed.

If you have any questions, please don’t hesitate to reach out. Thank you for your business, and have a great day!
Ace m.
Ace m. Checked in
Upon arrival, the homeowner stated that water was leaking through the ceiling and had noticed water around the air handler. After performing a diagnostic, I found that the condensate drain line was clogged, causing water to back up into the system and overflow onto the floor, which resulted in the ceiling leak. I completed a full system inspection and found a 20°F temperature difference between the supply and return, healthy refrigerant pressures, and all electrical components operating properly. I performed a condensate drain line treatment and verified that the drain line was flowing and draining properly after the service. At this time, the system is operating as designed. If you have any questions, please don’t hesitate to reach out. Thank you for your business, and have a great day!
Largo, FL 33771
Found clogged drain line. Cleaned and treated drain line and primary pan. Found system cooling with 10° split. Added 2lbs refrigerant and cleaned condenser coils. System now has good pressures and a 16-17° split. Let client know system may have a refrigerant leak. We will check pressures annd temp split again on next visit.
Found clogged drain line. Cleaned and treated drain line and primary pan. Found system cooling with 10° split. Added 2lbs refrigerant and cleaned condenser coils. System now has good pressures and a 16-17° split. Let client know system may have a refrigerant leak. We will check pressures annd temp split again on next visit.
Michael A.
Michael A. Checked in
Found clogged drain line. Cleaned and treated drain line and primary pan. Found system cooling with 10° split. Added 2lbs refrigerant and cleaned condenser coils. System now has good pressures and a 16-17° split. Let client know system may have a refrigerant leak. We will check pressures annd temp split again on next visit.
Largo, FL 33773
Found bedrooms not cooling properly due to original sheet metal ductwork. Bedrooms are recommended to be on separate mini split systems to guarantee proper comfort for rooms. Client is aware of age of ductwork and main unit. Told client to plan to replace in near future. Unit is cooling to the best of its ability at this time.
Found bedrooms not cooling properly due to original sheet metal ductwork. Bedrooms are recommended to be on separate mini split systems to guarantee proper comfort for rooms. Client is aware of age of ductwork and main unit. Told client to plan to replace in near future. Unit is cooling to the best of its ability at this time.
Justin G.
Justin G. Checked in
Found bedrooms not cooling properly due to original sheet metal ductwork. Bedrooms are recommended to be on separate mini split systems to guarantee proper comfort for rooms. Client is aware of age of ductwork and main unit. Told client to plan to replace in near future. Unit is cooling to the best of its ability at this time.
Largo, FL 33774
Diagnostic 
-drain line backing up causing system to intermittently shut off 
-outside capacitor reading weak on compressor side 
-Subcool value high due to dirty outdoor coils 

Scope of work 
-flush drain line & drain pan 
-added pan tablets to help with buildup 
-clean outdoor condenser coils
-replace outdoor capacitor 
-taped spliced outdoor wiring
-removed failed hard start kit 

Verified system is cooling & draining 
Complimentary cleaned outdoor coils 
Taped outdoor wiring 
Fan speed on low
Diagnostic 
-drain line backing up causing system to intermittently shut off 
-outside capacitor reading weak on compressor side 
-Subcool value high due to dirty outdoor coils 

Scope of work 
-flush drain line & drain pan 
-added pan tablets to help with buildup 
-clean outdoor condenser coils
-replace outdoor capacitor 
-taped spliced outdoor wiring
-removed failed hard start kit 

Verified system is cooling & draining 
Complimentary cleaned outdoor coils 
Taped outdoor wiring 
Fan speed on low
Nathan A.
Nathan A. Checked in
Diagnostic -drain line backing up causing system to intermittently shut off -outside capacitor reading weak on compressor side -Subcool value high due to dirty outdoor coils Scope of work -flush drain line & drain pan -added pan tablets to help with buildup -clean outdoor condenser coils -replace outdoor capacitor -taped spliced outdoor wiring -removed failed hard start kit Verified system is cooling & draining Complimentary cleaned outdoor coils Taped outdoor wiring Fan speed on low
Largo, FL 33770