Instant Quote Shop Filters Call Air Bros

St. Petersburg, FL

air-bros-team-with-truck

The Best AC Repair in St. Petersburg, FL — From Technicians Your Neighbors Already Trust

When your AC quits in the middle of a St. Pete summer, you don't want a stranger in an unmarked van. You want a technician your neighbors already know and trust. Air Bros Air Conditioning & Electrical has been fixing air conditioners in St. Petersburg since 2020, but our roots run deeper — founder Ricky Orta grew up learning the trade from his father and has been a licensed HVAC contractor since 2006. That local, hands-on experience is why homeowners from Historic Kenwood to Snell Isle call us the best AC repair company in St. Petersburg.

We're headquartered right here in the Shore Acres neighborhood, so when you call, you're not routed to a call center — you're talking to the same local team that services your street.

Call us at 727-217-6148 or contact us online today for all of your HVAC, indoor air quality and electrical needs.

Meet the technicians who service St. Petersburg

What to expect when we show up

Calling a repair company you've never used before shouldn't feel like a gamble. Here's exactly how an Air Bros service call goes, every time.

You'll get a heads-up before we arrive, then a uniformed technician in a marked Air Bros vehicle shows up in the window we promised. We diagnose the whole system — not just the obvious symptom — then explain what we found and what your options are before any work starts. You approve the price up front, we make the repair, and we don't leave until we've confirmed the system is cooling the way it should.

Every technician is a background-checked, drug-tested Air Bros employee — never a subcontractor — and each one is trained to service every major AC and heat pump brand. It's the kind of consistency you can only get from a local team that answers to its own name.

And if something isn't right? Our 100% satisfaction guarantee means we make it right.

Signs you need AC repair

St. Petersburg's heat and humidity push air conditioners harder than almost anywhere else in the country. Call for AC repair if you notice:

  • Warm air blowing from vents, or the system running constantly without cooling
  • Water pooling around your air handler (a common issue in St. Pete's older homes with attic-run drain lines)
  • Musty odors or visible mold near vents — a sign of a clogged condensate line or dirty coil
  • Rising humidity indoors despite the AC running
  • Short cycling, tripped breakers, or a system that won't turn on at all

Our technicians diagnose the full system on every call — refrigerant charge, temperature split, electrical connections, and drain line — so you get a real fix, not a temporary patch.

Comprehensive HVAC Services in St. Petersburg

We offer a full range of heating and cooling services to keep your St. Petersburg, FL, home comfortable year-round:

  • Air Conditioning: From AC repair and AC installation to routine maintenance, we ensure your cooling system keeps you comfortable during those hot Florida summers. We offer same-day service for AC emergencies, so you never have to suffer in the heat.
  • Heating: Stay warm and cozy in the winter with our comprehensive heating services. We repair and install all types of heating systems, including furnaces and heat pumps, and offer preventative maintenance to keep your system running efficiently.
  • Indoor Air Quality: Improve your indoor air quality with our dehumidifier and UV light installation services. We'll help you control excess humidity and eliminate airborne contaminants, creating a healthier home environment.
  • Ductwork: Ensure optimal airflow and energy efficiency with our ductwork repair and installation services. We can address leaks and damage, and design a system that's perfect for your home.
  • Pool Heater Services: Extend your swim season with our pool heater installation and repair services.
  • Electrical Services: From outlet and switch replacements to ceiling fan installations to whole-house surge protector installations, we have the experts to handle your electrical service needs.

Our experienced technicians are skilled in all aspects of HVAC service and are dedicated to providing top-quality workmanship and customer care.

Why Choose Air Bros?

  • Local Expertise: We understand the unique climate challenges of St. Petersburg.
  • Fast and Reliable Service: We offer same-day service for AC emergencies and prioritize prompt service for all your HVAC needs.
  • Experienced Technicians: Our team is highly trained and experienced in all aspects of HVAC service.
  • Upfront Pricing: We provide transparent pricing with no hidden costs.
  • Customer Satisfaction Guaranteed: Your comfort and satisfaction are our top priorities.

Contact Air Bros Today!

Whether you need emergency AC repair, a new heating system installation, or any other HVAC service, Air Bros is here to help. Contact us today for a free consultation or to schedule a service appointment. We're proud to be your trusted HVAC partner in St. Petersburg!

Call us at 727-217-6148 or contact us online today!

Recent Jobs and Reviews in St. Petersburg, FL

St. Petersburg, FL at a glance

Air Bros Air Conditioning & Electrical has completed 25 jobs in St. Petersburg, FL in July 2026.

The most recent job was on July 30, 2026.

Air Bros Air Conditioning & Electrical has completed 1,919 jobs in St. Petersburg, FL in the last 12 months. The first job there was in December 2024.

Job Locations and Reviews

Performed full system tuneup 

Home owner removed clog from condensate p trap 

Cleaned pump and drain line 

Cleaned drain pan

Added pan tablets to help with buildup 

Verified pump operations 

Glued broken pvc fitting 

Cleaned outdoor coils 

Checked filter and coils 

Verified IAQ operating 

System is currently operating and draining
Performed full system tuneup 

Home owner removed clog from condensate p trap 

Cleaned pump and drain line 

Cleaned drain pan

Added pan tablets to help with buildup 

Verified pump operations 

Glued broken pvc fitting 

Cleaned outdoor coils 

Checked filter and coils 

Verified IAQ operating 

System is currently operating and draining
Nathan A.
Nathan A. Checked in
Performed full system tuneup Home owner removed clog from condensate p trap Cleaned pump and drain line Cleaned drain pan Added pan tablets to help with buildup Verified pump operations Glued broken pvc fitting Cleaned outdoor coils Checked filter and coils Verified IAQ operating System is currently operating and draining
St. Petersburg, FL 33702
On arrival found unit freezing due to low refrigerant. Found leak in condenser coil. Temp split is poor. Unit not able to cool properly. Will provide estimate for system replacement.
On arrival found unit freezing due to low refrigerant. Found leak in condenser coil. Temp split is poor. Unit not able to cool properly. Will provide estimate for system replacement.
Justin G.
Justin G. Checked in
On arrival found unit freezing due to low refrigerant. Found leak in condenser coil. Temp split is poor. Unit not able to cool properly. Will provide estimate for system replacement.
St. Petersburg, FL 33702
Justin G.
Justin G. Checked in
On arrival found unit set and reading 73. Started unit. Temp split 20*. Float switch clear. Found unit to have schedule set and on. Turned schedule off. Filter clean. Unable to access roof due to wrong code for door. Unable to check pressures and electrical. Client will get correct code and call if we need to make return trip. Unit cooling.
St. Petersburg, FL 33701
Found clogged drain line. Performed drain cleaning and treatment. 
Client signed up for Maitenence plan today. 
Performed first Maitenence. Condenser coils cleaned, amp draws checked, temp split is poor at 16° prior to cleaning condenser coils. 
Client mentioned their father added refrigerant about 2 months ago. Explained that if system continues to lose refrigerant, we will need to perform a leak search as refrigerant cannot keep being added to a system with a known leak. 
System is cooling at this time and client would like to leave everything the way it is. 
Pressures indicate system is slightly low on refrigerant.
Found clogged drain line. Performed drain cleaning and treatment. 
Client signed up for Maitenence plan today. 
Performed first Maitenence. Condenser coils cleaned, amp draws checked, temp split is poor at 16° prior to cleaning condenser coils. 
Client mentioned their father added refrigerant about 2 months ago. Explained that if system continues to lose refrigerant, we will need to perform a leak search as refrigerant cannot keep being added to a system with a known leak. 
System is cooling at this time and client would like to leave everything the way it is. 
Pressures indicate system is slightly low on refrigerant.
Michael A.
Michael A. Checked in
Found clogged drain line. Performed drain cleaning and treatment. Client signed up for Maitenence plan today. Performed first Maitenence. Condenser coils cleaned, amp draws checked, temp split is poor at 16° prior to cleaning condenser coils. Client mentioned their father added refrigerant about 2 months ago. Explained that if system continues to lose refrigerant, we will need to perform a leak search as refrigerant cannot keep being added to a system with a known leak. System is cooling at this time and client would like to leave everything the way it is. Pressures indicate system is slightly low on refrigerant.
St. Petersburg, FL 33713
Upon my inspection, found failed primary float switch. 
Drain line backed up. 
Performed cleaning on drain line and explained that when we clean drains for the first time, often extra debris gets broken down from treating with chemicals and does not happen immediately with a Maitenence cleaning. 
Performed drain cleaning complimentary. 
Installed new primary float switch and tested functionality. 
System is cooling with a 19° temp split at this time. System is draining properly. 

1 year warranty on primary safety float switch
Upon my inspection, found failed primary float switch. 
Drain line backed up. 
Performed cleaning on drain line and explained that when we clean drains for the first time, often extra debris gets broken down from treating with chemicals and does not happen immediately with a Maitenence cleaning. 
Performed drain cleaning complimentary. 
Installed new primary float switch and tested functionality. 
System is cooling with a 19° temp split at this time. System is draining properly. 

1 year warranty on primary safety float switch
Michael A.
Michael A. Checked in
Upon my inspection, found failed primary float switch. Drain line backed up. Performed cleaning on drain line and explained that when we clean drains for the first time, often extra debris gets broken down from treating with chemicals and does not happen immediately with a Maitenence cleaning. Performed drain cleaning complimentary. Installed new primary float switch and tested functionality. System is cooling with a 19° temp split at this time. System is draining properly. 1 year warranty on primary safety float switch
St. Petersburg, FL 33713
Performed maintenance on system. Found weak capacitor and worn contactor causing fan motor to not turn on. Replaced parts. Amp draws good. Pressures good. Temp split good. Cleared pan and drain. Added chemical in pan to help prevent clogs. Found evap coil dirty. Performed chemical clean in place. Start and test. Unit cooling properly at this time.
Performed maintenance on system. Found weak capacitor and worn contactor causing fan motor to not turn on. Replaced parts. Amp draws good. Pressures good. Temp split good. Cleared pan and drain. Added chemical in pan to help prevent clogs. Found evap coil dirty. Performed chemical clean in place. Start and test. Unit cooling properly at this time.
Justin G.
Justin G. Checked in
Performed maintenance on system. Found weak capacitor and worn contactor causing fan motor to not turn on. Replaced parts. Amp draws good. Pressures good. Temp split good. Cleared pan and drain. Added chemical in pan to help prevent clogs. Found evap coil dirty. Performed chemical clean in place. Start and test. Unit cooling properly at this time.
St. Petersburg, FL 33703
St. Petersburg, FL - On arrival found unit not cooling due to arching condenser breaker. Removed panel cover and found bus bar and breakers burnt. Replaced air handler and condenser breakers. Start and test. Unit cooling properly with no error codes. Temp split in range. Will have electrician come out to perform free panel inspection. Unit cooling at this time.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to arching condenser breaker. Removed panel cover and found bus bar and breakers burnt. Replaced air handler and condenser breakers. Start and test. Unit cooling properly with no error codes. Temp split in range. Will have electrician come out to perform free panel inspection. Unit cooling at this time.
St. Petersburg, FL 33703
Upon arrival, found system not cooling. 
Outdoor condenser has a faulty capacitor. Replaced capacitor and replaced contactar as a precautionary as these components work together. 
Started system and found system cooling with a 13° temperature split. Inspected evaporator coils are clean enough. Found condenser coils dirty. Checked amp draws and found fan motor close to its max rating. Fan motor could potentially fail in the future but is within factory spec at this time. 
Client signed up for Maitenence plan so I cleaned the condenser coils as part of the Maitenence and also cleaned the drain line. After letting the coils dry, I found the system is low on refrigerant. I added 2lbs of refrigerant. Explained to client the system may have a potential refrigerant leak. Client opted to top off with refrigerant and see how long it lasts. We recommend re checking refrigerant pressures and temperature split on next Maitenence visit to verify if system is holding proper charge. 
System is now co
Upon arrival, found system not cooling. 
Outdoor condenser has a faulty capacitor. Replaced capacitor and replaced contactar as a precautionary as these components work together. 
Started system and found system cooling with a 13° temperature split. Inspected evaporator coils are clean enough. Found condenser coils dirty. Checked amp draws and found fan motor close to its max rating. Fan motor could potentially fail in the future but is within factory spec at this time. 
Client signed up for Maitenence plan so I cleaned the condenser coils as part of the Maitenence and also cleaned the drain line. After letting the coils dry, I found the system is low on refrigerant. I added 2lbs of refrigerant. Explained to client the system may have a potential refrigerant leak. Client opted to top off with refrigerant and see how long it lasts. We recommend re checking refrigerant pressures and temperature split on next Maitenence visit to verify if system is holding proper charge. 
System is now co
Michael A.
Michael A. Checked in
Upon arrival, found system not cooling. Outdoor condenser has a faulty capacitor. Replaced capacitor and replaced contactar as a precautionary as these components work together. Started system and found system cooling with a 13° temperature split. Inspected evaporator coils are clean enough. Found condenser coils dirty. Checked amp draws and found fan motor close to its max rating. Fan motor could potentially fail in the future but is within factory spec at this time. Client signed up for Maitenence plan so I cleaned the condenser coils as part of the Maitenence and also cleaned the drain line. After letting the coils dry, I found the system is low on refrigerant. I added 2lbs of refrigerant. Explained to client the system may have a potential refrigerant leak. Client opted to top off with refrigerant and see how long it lasts. We recommend re checking refrigerant pressures and temperature split on next Maitenence visit to verify if system is holding proper charge. System is now co
St. Petersburg, FL 33703
Griffin K.
Griffin K. Checked in
Install GFCI 20 amp breaker in pool panel
St. Petersburg, FL 33703
Performed a full diagnostic system was functioning properly. Homeowner poured vinegar down the flow switch on accident.
Performed a full diagnostic system was functioning properly. Homeowner poured vinegar down the flow switch on accident.
Ace m.
Ace m. Checked in
Performed a full diagnostic system was functioning properly. Homeowner poured vinegar down the flow switch on accident.
St. Petersburg, FL 33703
Master bedroom/office system:
Client states bedroom and office feel warmer than what the thermostat reads. Found thermostat off by 2-3°. Recalibrated thermostat. 
Client states a mark on the ceiling looks like water damage or mold. We determined it was a dirt smudge and we cleaned it off with all purpose cleaner. Ceiling is dry. 

Client says there was a power flicker a day or two ago. Could be why the thermostat was off a few degrees. 

System is cooling either way 25° temp split at this time. 
Air handler is dripping some water into the secondary pan. I let client know that their duct work still needs to be resolved and referred to the duct work quote I previously sent to resolve the issue. 

$90 labor charge for time and recalibration of thermostat today.
Master bedroom/office system:
Client states bedroom and office feel warmer than what the thermostat reads. Found thermostat off by 2-3°. Recalibrated thermostat. 
Client states a mark on the ceiling looks like water damage or mold. We determined it was a dirt smudge and we cleaned it off with all purpose cleaner. Ceiling is dry. 

Client says there was a power flicker a day or two ago. Could be why the thermostat was off a few degrees. 

System is cooling either way 25° temp split at this time. 
Air handler is dripping some water into the secondary pan. I let client know that their duct work still needs to be resolved and referred to the duct work quote I previously sent to resolve the issue. 

$90 labor charge for time and recalibration of thermostat today.
Michael A.
Michael A. Checked in
Master bedroom/office system: Client states bedroom and office feel warmer than what the thermostat reads. Found thermostat off by 2-3°. Recalibrated thermostat. Client states a mark on the ceiling looks like water damage or mold. We determined it was a dirt smudge and we cleaned it off with all purpose cleaner. Ceiling is dry. Client says there was a power flicker a day or two ago. Could be why the thermostat was off a few degrees. System is cooling either way 25° temp split at this time. Air handler is dripping some water into the secondary pan. I let client know that their duct work still needs to be resolved and referred to the duct work quote I previously sent to resolve the issue. $90 labor charge for time and recalibration of thermostat today.
St. Petersburg, FL 33702
Upon my inspection, found system low on refrigerant and system also has a faulty indoor blower motor. System running with a 30° temperature split causing ducts to sweat and inefficiency. 
Spoke with tech support. 
System replacement quotes sent.
Upon my inspection, found system low on refrigerant and system also has a faulty indoor blower motor. System running with a 30° temperature split causing ducts to sweat and inefficiency. 
Spoke with tech support. 
System replacement quotes sent.
Michael A.
Michael A. Checked in
Upon my inspection, found system low on refrigerant and system also has a faulty indoor blower motor. System running with a 30° temperature split causing ducts to sweat and inefficiency. Spoke with tech support. System replacement quotes sent.
St. Petersburg, FL 33713
St. Petersburg, FL - Inspected unit for not cooling. Pressures good. Amp draws good. Capacitor good. Contactor good. Diagnostic board shows error for compressor trip. Unit was cooling on arrival. Made client aware possible failing compressor. Told client to take video of loud noise if problem happens again and call immediately. 
Found air handler sweating due to improper sized plenums on unit. Return plenum causing large amounts of restrictions in airflow. Recommend in winter to have plenums replaced and enlarged for proper balance of system. Unit cooling at this time.
Justin G.
Justin G. Checked in
Inspected unit for not cooling. Pressures good. Amp draws good. Capacitor good. Contactor good. Diagnostic board shows error for compressor trip. Unit was cooling on arrival. Made client aware possible failing compressor. Told client to take video of loud noise if problem happens again and call immediately. Found air handler sweating due to improper sized plenums on unit. Return plenum causing large amounts of restrictions in airflow. Recommend in winter to have plenums replaced and enlarged for proper balance of system. Unit cooling at this time.
St. Petersburg, FL 33713
Diagnostic
-clogged drain line and pan causing unit to trip safety switch 

Scope of Work
-clear drain line and drain pan 
-add pan tablets to help with buildup 
-prime drain & trap 


Unit is currently operating within manufacture specifications
Diagnostic
-clogged drain line and pan causing unit to trip safety switch 

Scope of Work
-clear drain line and drain pan 
-add pan tablets to help with buildup 
-prime drain & trap 


Unit is currently operating within manufacture specifications
Nathan A.
Nathan A. Checked in
Diagnostic -clogged drain line and pan causing unit to trip safety switch Scope of Work -clear drain line and drain pan -add pan tablets to help with buildup -prime drain & trap Unit is currently operating within manufacture specifications
St. Petersburg, FL 33702
Full system tuneup (2 split systems)

Upstairs Trane system operating within manufacture specifications 

Downstairs 5T Heil system has active leak. Home owner would like to charge system than do leak search/repair/replacement in future 

Charged system 4lbs back to factory specifications. Explained no guarantee on life span of charge
Full system tuneup (2 split systems)

Upstairs Trane system operating within manufacture specifications 

Downstairs 5T Heil system has active leak. Home owner would like to charge system than do leak search/repair/replacement in future 

Charged system 4lbs back to factory specifications. Explained no guarantee on life span of charge
Nathan A.
Nathan A. Checked in
Full system tuneup (2 split systems) Upstairs Trane system operating within manufacture specifications Downstairs 5T Heil system has active leak. Home owner would like to charge system than do leak search/repair/replacement in future Charged system 4lbs back to factory specifications. Explained no guarantee on life span of charge
St. Petersburg, FL 33702
Reason for call:
Precision tune up 

Equipment:
2015 2.5 ton Goodman 
Horizontal in attic 
Condenser located on right side 

Summary:
Completed visit to find system low on charge. Found oil in drain pan insinuating leak in Evap coil. Informed homeowner of options. Homeowner chose replacement. Work was sold and scheduled for Thursday.
Reason for call:
Precision tune up 

Equipment:
2015 2.5 ton Goodman 
Horizontal in attic 
Condenser located on right side 

Summary:
Completed visit to find system low on charge. Found oil in drain pan insinuating leak in Evap coil. Informed homeowner of options. Homeowner chose replacement. Work was sold and scheduled for Thursday.
Corbin C.
Corbin C. Checked in
Reason for call: Precision tune up Equipment: 2015 2.5 ton Goodman Horizontal in attic Condenser located on right side Summary: Completed visit to find system low on charge. Found oil in drain pan insinuating leak in Evap coil. Informed homeowner of options. Homeowner chose replacement. Work was sold and scheduled for Thursday.
St. Petersburg, FL 33714
Diagnosis 
-outdoor capacitor failed 
-wiring front contactor burnt up (loose connections)

Scope of work 
-replace failed capacitor 
-splice new wiring connections 

Unit is not properly matched and out of warranty. Same issues as previous visit. System was also charged with MO99 (R-438A)

Home owner would like to wait till replace. Due to system issues and being charged with drop in refrigeration/age of system. Still recommend replacement.

No guarantee on lifespan of system or repairs being made

System is currently cooling to best ability
Diagnosis 
-outdoor capacitor failed 
-wiring front contactor burnt up (loose connections)

Scope of work 
-replace failed capacitor 
-splice new wiring connections 

Unit is not properly matched and out of warranty. Same issues as previous visit. System was also charged with MO99 (R-438A)

Home owner would like to wait till replace. Due to system issues and being charged with drop in refrigeration/age of system. Still recommend replacement.

No guarantee on lifespan of system or repairs being made

System is currently cooling to best ability
Nathan A.
Nathan A. Checked in
Diagnosis -outdoor capacitor failed -wiring front contactor burnt up (loose connections) Scope of work -replace failed capacitor -splice new wiring connections Unit is not properly matched and out of warranty. Same issues as previous visit. System was also charged with MO99 (R-438A) Home owner would like to wait till replace. Due to system issues and being charged with drop in refrigeration/age of system. Still recommend replacement. No guarantee on lifespan of system or repairs being made System is currently cooling to best ability
St. Petersburg, FL 33705
Diagnostic 
-drain line backing up causing water to overflow 
-primary safety had slime on it causing not to trip 
-coupler to common stack (if issue persist will need to call hoa and plumber)

Scope of work
-vacuumed drain line and drain pan 
-cleaned safety and glued properly to system 
-nitrogen purged drain line 
-added pan tablets and drain solution 
10% Off 

System is operating within manufacture specifications
Diagnostic 
-drain line backing up causing water to overflow 
-primary safety had slime on it causing not to trip 
-coupler to common stack (if issue persist will need to call hoa and plumber)

Scope of work
-vacuumed drain line and drain pan 
-cleaned safety and glued properly to system 
-nitrogen purged drain line 
-added pan tablets and drain solution 
10% Off 

System is operating within manufacture specifications
Nathan A.
Nathan A. Checked in
Diagnostic -drain line backing up causing water to overflow -primary safety had slime on it causing not to trip -coupler to common stack (if issue persist will need to call hoa and plumber) Scope of work -vacuumed drain line and drain pan -cleaned safety and glued properly to system -nitrogen purged drain line -added pan tablets and drain solution 10% Off System is operating within manufacture specifications
St. Petersburg, FL 33713
Corbin C.
Corbin C. Checked in
Install client supplied nest. Start and test. Tax and labor included.
St. Petersburg, FL 33702
Found system flooded during hurricane. 
New compressor, contactar, capacitor, and refrigerant lineset leak repair needed. 
Sending quotes for repairs and full replacement option along with raising the system
Found system flooded during hurricane. 
New compressor, contactar, capacitor, and refrigerant lineset leak repair needed. 
Sending quotes for repairs and full replacement option along with raising the system
Michael A.
Michael A. Checked in
Found system flooded during hurricane. New compressor, contactar, capacitor, and refrigerant lineset leak repair needed. Sending quotes for repairs and full replacement option along with raising the system
St. Petersburg, FL 33703
Reason for call:
Ac not keeping up 

Summary:
On arrival unit was operating cooling draining well homeowners informed me that they were on vacation and they turned the AC off when they came back. It was 86° and it took a long time for the AC to catch back up. They thought it would cool down quicker than it did.   In the summertime in Florida. We typically see 1° per hour. It roughly took 14 hours for the AC system to catch up. thermostat was set to 72 and satisfied at 72 during today's visit.
Informed them that they should just have a set temperature higher when they leave. Explained basic efficiencies and operation of the equipment to educate them a little. Unable to access condensing unit due to no information for rooftop. Unit is cooling with a 20° split no issues presented today.
Reason for call:
Ac not keeping up 

Summary:
On arrival unit was operating cooling draining well homeowners informed me that they were on vacation and they turned the AC off when they came back. It was 86° and it took a long time for the AC to catch back up. They thought it would cool down quicker than it did.   In the summertime in Florida. We typically see 1° per hour. It roughly took 14 hours for the AC system to catch up. thermostat was set to 72 and satisfied at 72 during today's visit.
Informed them that they should just have a set temperature higher when they leave. Explained basic efficiencies and operation of the equipment to educate them a little. Unable to access condensing unit due to no information for rooftop. Unit is cooling with a 20° split no issues presented today.
Corbin C.
Corbin C. Checked in
Reason for call: Ac not keeping up Summary: On arrival unit was operating cooling draining well homeowners informed me that they were on vacation and they turned the AC off when they came back. It was 86° and it took a long time for the AC to catch back up. They thought it would cool down quicker than it did. In the summertime in Florida. We typically see 1° per hour. It roughly took 14 hours for the AC system to catch up. thermostat was set to 72 and satisfied at 72 during today's visit. Informed them that they should just have a set temperature higher when they leave. Explained basic efficiencies and operation of the equipment to educate them a little. Unable to access condensing unit due to no information for rooftop. Unit is cooling with a 20° split no issues presented today.
St. Petersburg, FL 33701
Diagnostic 
-gfi tripped to condensate pump causing unit not to drain 
-pump sits directly on ceiling with no pan beneath 

Secondary pan filled with water. Vacuumed all water out of pan. Reset gfi and pump began to run. Unit is currently draining and operating within manufacture specifications Notes

Secondary pan heavily rusted, unit has overfilled in past. 

Will get electrician out to see if there’s an alternative to gfi and see how outlets are wired. Home owner states she’s had to reset gfi in bathroom which sits below air handler. 

Possibility condensate pump is going bad as well
Diagnostic 
-gfi tripped to condensate pump causing unit not to drain 
-pump sits directly on ceiling with no pan beneath 

Secondary pan filled with water. Vacuumed all water out of pan. Reset gfi and pump began to run. Unit is currently draining and operating within manufacture specifications Notes

Secondary pan heavily rusted, unit has overfilled in past. 

Will get electrician out to see if there’s an alternative to gfi and see how outlets are wired. Home owner states she’s had to reset gfi in bathroom which sits below air handler. 

Possibility condensate pump is going bad as well
Nathan A.
Nathan A. Checked in
Diagnostic -gfi tripped to condensate pump causing unit not to drain -pump sits directly on ceiling with no pan beneath Secondary pan filled with water. Vacuumed all water out of pan. Reset gfi and pump began to run. Unit is currently draining and operating within manufacture specifications Notes Secondary pan heavily rusted, unit has overfilled in past. Will get electrician out to see if there’s an alternative to gfi and see how outlets are wired. Home owner states she’s had to reset gfi in bathroom which sits below air handler. Possibility condensate pump is going bad as well
St. Petersburg, FL 33705
Performed first tune up on system. 
Found clogged drain line causing back up in the package unit and possibly adding to the smell the client had concerns with. 
Cleaned and treated drain line and primary pan. Drain line is improperly sized going from 3/4” to 1/2”. Let client know it should be 3/4 throughout. They want to handle it themselves. 
Checked amp draws. Capacitor is out of factory range. Replaced capacitor. Found bacterial growth inside blower compartment. Recommended sanitizing and installation of UV air purifier with 2 year warranty. Installer UV system after cleaning up and protecting wiring and the motor. Vacuumed out as much water as I could from the blower compartment but it will need days to dry out. 
System is cooling at this time.
Performed first tune up on system. 
Found clogged drain line causing back up in the package unit and possibly adding to the smell the client had concerns with. 
Cleaned and treated drain line and primary pan. Drain line is improperly sized going from 3/4” to 1/2”. Let client know it should be 3/4 throughout. They want to handle it themselves. 
Checked amp draws. Capacitor is out of factory range. Replaced capacitor. Found bacterial growth inside blower compartment. Recommended sanitizing and installation of UV air purifier with 2 year warranty. Installer UV system after cleaning up and protecting wiring and the motor. Vacuumed out as much water as I could from the blower compartment but it will need days to dry out. 
System is cooling at this time.
Michael A.
Michael A. Checked in
Performed first tune up on system. Found clogged drain line causing back up in the package unit and possibly adding to the smell the client had concerns with. Cleaned and treated drain line and primary pan. Drain line is improperly sized going from 3/4” to 1/2”. Let client know it should be 3/4 throughout. They want to handle it themselves. Checked amp draws. Capacitor is out of factory range. Replaced capacitor. Found bacterial growth inside blower compartment. Recommended sanitizing and installation of UV air purifier with 2 year warranty. Installer UV system after cleaning up and protecting wiring and the motor. Vacuumed out as much water as I could from the blower compartment but it will need days to dry out. System is cooling at this time.
St. Petersburg, FL 33710
Reason for call:
No cool 

Equipment:
2025 ruud 3 ton 
Horizontal in attic 
Condenser located on right side of home 

Summary:
Found a failed dual capacitor part was replaced under parts and labor warranty. 

Operation was restored to the equipment unit cooling with 20 degree split.
Reason for call:
No cool 

Equipment:
2025 ruud 3 ton 
Horizontal in attic 
Condenser located on right side of home 

Summary:
Found a failed dual capacitor part was replaced under parts and labor warranty. 

Operation was restored to the equipment unit cooling with 20 degree split.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Equipment: 2025 ruud 3 ton Horizontal in attic Condenser located on right side of home Summary: Found a failed dual capacitor part was replaced under parts and labor warranty. Operation was restored to the equipment unit cooling with 20 degree split.
St. Petersburg, FL 33713
System not cooling. Bad capacitor. Contactar is also old and worn. Replaced capacitor and contactar. 
Started system. Found condenser disconnect is bypassed and recommended replacing. 
System is cooling with a 20° temperature split and good amp draws at this time. 
Air handler and condenser are two different years and manufacturers. Let client know. 
Client takes care of their own drain line and are not interested in Maitenence plan at this time.
System not cooling. Bad capacitor. Contactar is also old and worn. Replaced capacitor and contactar. 
Started system. Found condenser disconnect is bypassed and recommended replacing. 
System is cooling with a 20° temperature split and good amp draws at this time. 
Air handler and condenser are two different years and manufacturers. Let client know. 
Client takes care of their own drain line and are not interested in Maitenence plan at this time.
Michael A.
Michael A. Checked in
System not cooling. Bad capacitor. Contactar is also old and worn. Replaced capacitor and contactar. Started system. Found condenser disconnect is bypassed and recommended replacing. System is cooling with a 20° temperature split and good amp draws at this time. Air handler and condenser are two different years and manufacturers. Let client know. Client takes care of their own drain line and are not interested in Maitenence plan at this time.
St. Petersburg, FL 33702
How do I know if my AC needs repair or full replacement?

Our technicians inspect the full system — age, refrigerant type, corrosion, and repair history — and give you an honest recommendation. If a repair makes sense, we'll fix it. If the unit is beyond its useful life, we'll walk you through replacement options with no pressure.

Are your technicians background-checked and licensed?

Yes. Every Air Bros technician is background-checked, factory-trained, and works under our state HVAC license (#CAC1820499) and electrical license (#EC13015085).

What parts of St. Petersburg do you serve?

We serve all of St. Petersburg, including Downtown, Historic Kenwood, Old Northeast, Snell Isle, Crescent Lake, Shore Acres, and Coquina Key, plus Seminole, Largo, Pinellas Park, and the surrounding beach communities.

Do you offer same-day AC repair in St. Petersburg?

Yes. We offer 24/7 emergency AC repair with same-day service throughout St. Petersburg and the surrounding Pinellas County area.

Is Air Bros a local St. Petersburg company, or a franchise?

Air Bros is 100% locally owned and operated, headquartered in the Shore Acres neighborhood of St. Petersburg. We're not a franchise — every technician is a direct employee, not a subcontractor.

Contact the Bros You Know Today!

Gravity Forms Pagination Must be Steps