Instant Quote Shop Filters Call Air Bros

St. Petersburg, FL

air-bros-team-with-truck

The Best AC Repair in St. Petersburg, FL — From Technicians Your Neighbors Already Trust

When your AC quits in the middle of a St. Pete summer, you don't want a stranger in an unmarked van. You want a technician your neighbors already know and trust. Air Bros Air Conditioning & Electrical has been fixing air conditioners in St. Petersburg since 2020, but our roots run deeper — founder Ricky Orta grew up learning the trade from his father and has been a licensed HVAC contractor since 2006. That local, hands-on experience is why homeowners from Historic Kenwood to Snell Isle call us the best AC repair company in St. Petersburg.

We're headquartered right here in the Shore Acres neighborhood, so when you call, you're not routed to a call center — you're talking to the same local team that services your street.

Call us at 727-217-6148 or contact us online today for all of your HVAC, indoor air quality and electrical needs.

Meet the technicians who service St. Petersburg

What to expect when we show up

Calling a repair company you've never used before shouldn't feel like a gamble. Here's exactly how an Air Bros service call goes, every time.

You'll get a heads-up before we arrive, then a uniformed technician in a marked Air Bros vehicle shows up in the window we promised. We diagnose the whole system — not just the obvious symptom — then explain what we found and what your options are before any work starts. You approve the price up front, we make the repair, and we don't leave until we've confirmed the system is cooling the way it should.

Every technician is a background-checked, drug-tested Air Bros employee — never a subcontractor — and each one is trained to service every major AC and heat pump brand. It's the kind of consistency you can only get from a local team that answers to its own name.

And if something isn't right? Our 100% satisfaction guarantee means we make it right.

Signs you need AC repair

St. Petersburg's heat and humidity push air conditioners harder than almost anywhere else in the country. Call for AC repair if you notice:

  • Warm air blowing from vents, or the system running constantly without cooling
  • Water pooling around your air handler (a common issue in St. Pete's older homes with attic-run drain lines)
  • Musty odors or visible mold near vents — a sign of a clogged condensate line or dirty coil
  • Rising humidity indoors despite the AC running
  • Short cycling, tripped breakers, or a system that won't turn on at all

Our technicians diagnose the full system on every call — refrigerant charge, temperature split, electrical connections, and drain line — so you get a real fix, not a temporary patch.

Comprehensive HVAC Services in St. Petersburg

We offer a full range of heating and cooling services to keep your St. Petersburg, FL, home comfortable year-round:

  • Air Conditioning: From AC repair and AC installation to routine maintenance, we ensure your cooling system keeps you comfortable during those hot Florida summers. We offer same-day service for AC emergencies, so you never have to suffer in the heat.
  • Heating: Stay warm and cozy in the winter with our comprehensive heating services. We repair and install all types of heating systems, including furnaces and heat pumps, and offer preventative maintenance to keep your system running efficiently.
  • Indoor Air Quality: Improve your indoor air quality with our dehumidifier and UV light installation services. We'll help you control excess humidity and eliminate airborne contaminants, creating a healthier home environment.
  • Ductwork: Ensure optimal airflow and energy efficiency with our ductwork repair and installation services. We can address leaks and damage, and design a system that's perfect for your home.
  • Pool Heater Services: Extend your swim season with our pool heater installation and repair services.
  • Electrical Services: From outlet and switch replacements to ceiling fan installations to whole-house surge protector installations, we have the experts to handle your electrical service needs.

Our experienced technicians are skilled in all aspects of HVAC service and are dedicated to providing top-quality workmanship and customer care.

Why Choose Air Bros?

  • Local Expertise: We understand the unique climate challenges of St. Petersburg.
  • Fast and Reliable Service: We offer same-day service for AC emergencies and prioritize prompt service for all your HVAC needs.
  • Experienced Technicians: Our team is highly trained and experienced in all aspects of HVAC service.
  • Upfront Pricing: We provide transparent pricing with no hidden costs.
  • Customer Satisfaction Guaranteed: Your comfort and satisfaction are our top priorities.

Contact Air Bros Today!

Whether you need emergency AC repair, a new heating system installation, or any other HVAC service, Air Bros is here to help. Contact us today for a free consultation or to schedule a service appointment. We're proud to be your trusted HVAC partner in St. Petersburg!

Call us at 727-217-6148 or contact us online today!

Recent Jobs and Reviews in St. Petersburg, FL

St. Petersburg, FL at a glance

Air Bros Air Conditioning & Electrical has completed 25 jobs in St. Petersburg, FL in July 2026.

The most recent job was on July 25, 2026.

Air Bros Air Conditioning & Electrical has completed 1,919 jobs in St. Petersburg, FL in the last 12 months. The first job there was in December 2024.

Job Locations and Reviews

Justin G.
Justin G. Checked in
On arrival found unit not cooling due to tripped float switch. Drain and pan has growth casing drain to plug. Client declined drain cleaning at this time and will try to clear themselves. Emptied float switch for temporary cooling and told client it will shut down again soon.
St. Petersburg, FL 33714
Performed leak search on system and found condenser coil leaking. Will provide estimate with price and availability on Monday. Client declined adding refrigerant at this time. Unit not cooling
Performed leak search on system and found condenser coil leaking. Will provide estimate with price and availability on Monday. Client declined adding refrigerant at this time. Unit not cooling
Justin G.
Justin G. Checked in
Performed leak search on system and found condenser coil leaking. Will provide estimate with price and availability on Monday. Client declined adding refrigerant at this time. Unit not cooling
St. Petersburg, FL 33703
St. Petersburg, FL - Found unit set to 72 and reading 72. Found attic has no insulation and home has original windows from 1940. Explained to client that until insulation and windows are done that the system will continue to struggle in late afternoon. Unit cooling with 20* split.
Justin G.
Justin G. Checked in
Found unit set to 72 and reading 72. Found attic has no insulation and home has original windows from 1940. Explained to client that until insulation and windows are done that the system will continue to struggle in late afternoon. Unit cooling with 20* split.
St. Petersburg, FL 33704
On arrival found unit not cooling properly due to tripped float switch. Cleared pan and drain. Added chemical to help prevent growth in pan. Tested unit. Found worn and burnt contactor. Client declined repair. Pressure are inaccurate due to improper lineset. Rinsed condenser coil. Unit is cooling and draining at this time.
On arrival found unit not cooling properly due to tripped float switch. Cleared pan and drain. Added chemical to help prevent growth in pan. Tested unit. Found worn and burnt contactor. Client declined repair. Pressure are inaccurate due to improper lineset. Rinsed condenser coil. Unit is cooling and draining at this time.
Justin G.
Justin G. Checked in
On arrival found unit not cooling properly due to tripped float switch. Cleared pan and drain. Added chemical to help prevent growth in pan. Tested unit. Found worn and burnt contactor. Client declined repair. Pressure are inaccurate due to improper lineset. Rinsed condenser coil. Unit is cooling and draining at this time.
St. Petersburg, FL 33705
Client states thermostat no responding for cooling. She inspected unit. Pressures good. Temp split good. Float switches clear and operational. Recommend for client to replace thermostat. Will return on Monday to install client supplied nest . Unit cooling properly.
Client states thermostat no responding for cooling. She inspected unit. Pressures good. Temp split good. Float switches clear and operational. Recommend for client to replace thermostat. Will return on Monday to install client supplied nest . Unit cooling properly.
Justin G.
Justin G. Checked in
Client states thermostat no responding for cooling. She inspected unit. Pressures good. Temp split good. Float switches clear and operational. Recommend for client to replace thermostat. Will return on Monday to install client supplied nest . Unit cooling properly.
St. Petersburg, FL 33702
On arrival found unit not cooling due to blown fuse. Inspected unit and found shorted defrost board and bad thermostat. Replaced thermostat. By passed board for temporary cooling. Will submit estimate for defrost board replacement. Float switches are operational. Temp split good. Unit cooling at this time.
On arrival found unit not cooling due to blown fuse. Inspected unit and found shorted defrost board and bad thermostat. Replaced thermostat. By passed board for temporary cooling. Will submit estimate for defrost board replacement. Float switches are operational. Temp split good. Unit cooling at this time.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to blown fuse. Inspected unit and found shorted defrost board and bad thermostat. Replaced thermostat. By passed board for temporary cooling. Will submit estimate for defrost board replacement. Float switches are operational. Temp split good. Unit cooling at this time.
St. Petersburg, FL 33705
Upon arrival, the homeowner stated that a previous inspector had noted the evaporator coil was dirty and recommended it be cleaned. Upon inspection, I found the evaporator coil to be severely restricted with hair and dust buildup, leaving very little open surface area for proper airflow.

I performed an in-place coil cleaning and removed as much hair and debris as possible. While an in-place cleaning cannot restore the coil to like-new condition, it successfully eliminated the airflow restriction. The coil is not in perfect condition, but it is no longer causing any significant airflow issues, which will help improve overall system performance and efficiency.

After the cleaning, I verified system operation and checked the temperature split. The system is producing a healthy 18°F temperature difference, and all readings are within normal operating range. At this time, the system is functioning properly with no performance concerns.
Upon arrival, the homeowner stated that a previous inspector had noted the evaporator coil was dirty and recommended it be cleaned. Upon inspection, I found the evaporator coil to be severely restricted with hair and dust buildup, leaving very little open surface area for proper airflow.

I performed an in-place coil cleaning and removed as much hair and debris as possible. While an in-place cleaning cannot restore the coil to like-new condition, it successfully eliminated the airflow restriction. The coil is not in perfect condition, but it is no longer causing any significant airflow issues, which will help improve overall system performance and efficiency.

After the cleaning, I verified system operation and checked the temperature split. The system is producing a healthy 18°F temperature difference, and all readings are within normal operating range. At this time, the system is functioning properly with no performance concerns.
Ace m.
Ace m. Checked in
Upon arrival, the homeowner stated that a previous inspector had noted the evaporator coil was dirty and recommended it be cleaned. Upon inspection, I found the evaporator coil to be severely restricted with hair and dust buildup, leaving very little open surface area for proper airflow. I performed an in-place coil cleaning and removed as much hair and debris as possible. While an in-place cleaning cannot restore the coil to like-new condition, it successfully eliminated the airflow restriction. The coil is not in perfect condition, but it is no longer causing any significant airflow issues, which will help improve overall system performance and efficiency. After the cleaning, I verified system operation and checked the temperature split. The system is producing a healthy 18°F temperature difference, and all readings are within normal operating range. At this time, the system is functioning properly with no performance concerns.
St. Petersburg, FL 33701
System is operating within manufacture specifications 

Home has little to no insulation and single pain windows. System is also 10 years of age and becoming inefficient. 

Recommended insulation company
System is operating within manufacture specifications 

Home has little to no insulation and single pain windows. System is also 10 years of age and becoming inefficient. 

Recommended insulation company
Nathan A.
Nathan A. Checked in
System is operating within manufacture specifications Home has little to no insulation and single pain windows. System is also 10 years of age and becoming inefficient. Recommended insulation company
St. Petersburg, FL 33704
Client states duct was disconnected under home. Found duct separated for room. Pushed ducts back together to temporarily help with air flow. Found all ducts u see home are improper. Ducts are attic flex and should be mobile home flex that is required by code. Client is having foundation repairs made and will call once work is complete to give accurate estimate for replace all ducts. Access is very tight and will be expanded during foundation work for better serviceability.
Client states duct was disconnected under home. Found duct separated for room. Pushed ducts back together to temporarily help with air flow. Found all ducts u see home are improper. Ducts are attic flex and should be mobile home flex that is required by code. Client is having foundation repairs made and will call once work is complete to give accurate estimate for replace all ducts. Access is very tight and will be expanded during foundation work for better serviceability.
Justin G.
Justin G. Checked in
Client states duct was disconnected under home. Found duct separated for room. Pushed ducts back together to temporarily help with air flow. Found all ducts u see home are improper. Ducts are attic flex and should be mobile home flex that is required by code. Client is having foundation repairs made and will call once work is complete to give accurate estimate for replace all ducts. Access is very tight and will be expanded during foundation work for better serviceability.
St. Petersburg, FL 33705
On arrival found unit not cooling due to tripped breaker caused by grounded compressor. Unit is 16 year old r22 and we are unable to offer repair options. Will submit estimate for system replacement.
On arrival found unit not cooling due to tripped breaker caused by grounded compressor. Unit is 16 year old r22 and we are unable to offer repair options. Will submit estimate for system replacement.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to tripped breaker caused by grounded compressor. Unit is 16 year old r22 and we are unable to offer repair options. Will submit estimate for system replacement.
St. Petersburg, FL 33712
Reason for call:
No cool 

Equipment:
2024 ruud 
Horizontal in attic
Condenser on left side of home 

Summary:
Found dead capacitor replaced part under parts and labor warranty. 
20 degree split. Unit operating well now. 
Homeowner signed up for maintenance plan.
Reason for call:
No cool 

Equipment:
2024 ruud 
Horizontal in attic
Condenser on left side of home 

Summary:
Found dead capacitor replaced part under parts and labor warranty. 
20 degree split. Unit operating well now. 
Homeowner signed up for maintenance plan.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Equipment: 2024 ruud Horizontal in attic Condenser on left side of home Summary: Found dead capacitor replaced part under parts and labor warranty. 20 degree split. Unit operating well now. Homeowner signed up for maintenance plan.
St. Petersburg, FL 33704
Diagnostic 
-failed outdoor capacitor causing unit not to turn on 

Went over repair and maintenance agreement with home owner 

Scope of work 
-replace and wire 40/5 capacitor 

Verify system operations 

System is currently cooling
Diagnostic 
-failed outdoor capacitor causing unit not to turn on 

Went over repair and maintenance agreement with home owner 

Scope of work 
-replace and wire 40/5 capacitor 

Verify system operations 

System is currently cooling
Nathan A.
Nathan A. Checked in
Diagnostic -failed outdoor capacitor causing unit not to turn on Went over repair and maintenance agreement with home owner Scope of work -replace and wire 40/5 capacitor Verify system operations System is currently cooling
St. Petersburg, FL 33703
Found system to be extremely low in charge. 
Informed homeowner and he only wanted to add 410. 
After restoring operation to equipment found drain line to be constantly leaking in homeowners garage. Informed homeowner I could fix water leak he wanted to place down a bucket instead. 
Unit is cooling with 20 degree split. This could be a temporary fix. 

Add three pounds to balance systems pressure
Found system to be extremely low in charge. 
Informed homeowner and he only wanted to add 410. 
After restoring operation to equipment found drain line to be constantly leaking in homeowners garage. Informed homeowner I could fix water leak he wanted to place down a bucket instead. 
Unit is cooling with 20 degree split. This could be a temporary fix. 

Add three pounds to balance systems pressure
Corbin C.
Corbin C. Checked in
Found system to be extremely low in charge. Informed homeowner and he only wanted to add 410. After restoring operation to equipment found drain line to be constantly leaking in homeowners garage. Informed homeowner I could fix water leak he wanted to place down a bucket instead. Unit is cooling with 20 degree split. This could be a temporary fix. Add three pounds to balance systems pressure
St. Petersburg, FL 33703
Reason for call:
Tune up 

Equipment:
2021 oxbox 4 ton 
Vertical in closet 
Condenser out back 

Summary:
Completed service to find AC operating within manufacturing specification. Flush indoor and outdoor coils, flush drain pan, drain line and condensate pump. Filter needs attention. Homeowner decided to sign up on maintenance plan. Confirm pressures, capacitor, readings, and temperatures.
Reason for call:
Tune up 

Equipment:
2021 oxbox 4 ton 
Vertical in closet 
Condenser out back 

Summary:
Completed service to find AC operating within manufacturing specification. Flush indoor and outdoor coils, flush drain pan, drain line and condensate pump. Filter needs attention. Homeowner decided to sign up on maintenance plan. Confirm pressures, capacitor, readings, and temperatures.
Corbin C.
Corbin C. Checked in
Reason for call: Tune up Equipment: 2021 oxbox 4 ton Vertical in closet Condenser out back Summary: Completed service to find AC operating within manufacturing specification. Flush indoor and outdoor coils, flush drain pan, drain line and condensate pump. Filter needs attention. Homeowner decided to sign up on maintenance plan. Confirm pressures, capacitor, readings, and temperatures.
St. Petersburg, FL 33702
Performed tune up on two systems. 
Main system:
Deficiencies-
Outdoor condenser fan motor over amping
Evaporator coils are severely plugged and corroded
Blower wheel has debris and bacterial growth
Air handler has bacterial growth everywhere

Performed condenser coil cleaning and drain line cleaning. Temperature split is 19°. Compressor amp draw is ok. Capacitor is testing within factory tolerance. Changed air filter. 

Mini split:
Deficiencies- 
Found severely dirty indoor blower wheel with heavy bacterial growth. Recommending full cleaning and installation of UV system for future prevention. 
Cleaned and treated drain line 
Cleaned coils
Cleaned air filters
Condenser coils are very dirty, cleaned thoroughly 
Temperature split is 20°

Let client know all of the deficiencies with the systems. 
Recommended blower pull and clean on the mini split with an installation of a UV system. 
Talked about installing a new main system to solve all issues and cover under warranty.
Performed tune up on two systems. 
Main system:
Deficiencies-
Outdoor condenser fan motor over amping
Evaporator coils are severely plugged and corroded
Blower wheel has debris and bacterial growth
Air handler has bacterial growth everywhere

Performed condenser coil cleaning and drain line cleaning. Temperature split is 19°. Compressor amp draw is ok. Capacitor is testing within factory tolerance. Changed air filter. 

Mini split:
Deficiencies- 
Found severely dirty indoor blower wheel with heavy bacterial growth. Recommending full cleaning and installation of UV system for future prevention. 
Cleaned and treated drain line 
Cleaned coils
Cleaned air filters
Condenser coils are very dirty, cleaned thoroughly 
Temperature split is 20°

Let client know all of the deficiencies with the systems. 
Recommended blower pull and clean on the mini split with an installation of a UV system. 
Talked about installing a new main system to solve all issues and cover under warranty.
Michael A.
Michael A. Checked in
Performed tune up on two systems. Main system: Deficiencies- Outdoor condenser fan motor over amping Evaporator coils are severely plugged and corroded Blower wheel has debris and bacterial growth Air handler has bacterial growth everywhere Performed condenser coil cleaning and drain line cleaning. Temperature split is 19°. Compressor amp draw is ok. Capacitor is testing within factory tolerance. Changed air filter. Mini split: Deficiencies- Found severely dirty indoor blower wheel with heavy bacterial growth. Recommending full cleaning and installation of UV system for future prevention. Cleaned and treated drain line Cleaned coils Cleaned air filters Condenser coils are very dirty, cleaned thoroughly Temperature split is 20° Let client know all of the deficiencies with the systems. Recommended blower pull and clean on the mini split with an installation of a UV system. Talked about installing a new main system to solve all issues and cover under warranty.
St. Petersburg, FL 33704
Client states unit not cooling yesterday. Found system operating when arrived. Temp split good. Pressures good. Capacitor and contactor good. Amp draws are concerning for outdoor fan motor. Found water in float. Cleared pan and drain. Due to pitch of drain water stays in bottom of float switch. Told client to call if unit stops cooling again. Unable to fully diagnose system at this time.
Client states unit not cooling yesterday. Found system operating when arrived. Temp split good. Pressures good. Capacitor and contactor good. Amp draws are concerning for outdoor fan motor. Found water in float. Cleared pan and drain. Due to pitch of drain water stays in bottom of float switch. Told client to call if unit stops cooling again. Unable to fully diagnose system at this time.
Justin G.
Justin G. Checked in
Client states unit not cooling yesterday. Found system operating when arrived. Temp split good. Pressures good. Capacitor and contactor good. Amp draws are concerning for outdoor fan motor. Found water in float. Cleared pan and drain. Due to pitch of drain water stays in bottom of float switch. Told client to call if unit stops cooling again. Unable to fully diagnose system at this time.
St. Petersburg, FL 33701
Outdoor fan motor starting to fail. Will call for replacement/warranty
Outdoor fan motor starting to fail. Will call for replacement/warranty
Nathan A.
Nathan A. Checked in
Outdoor fan motor starting to fail. Will call for replacement/warranty
St. Petersburg, FL 33702
Inspected for possible hvac water leak. Client said roofer came out earlier today and said it was not a roof related issue. The water leak issue happened right during/after a major rain storm. 
Upon my inspection, found no evidence of any hvac equipment or ducts causing excessive water damage at the area of concern. 
I let client know they should wait for another rain storm and if the issue happens again that it is most likely a roofing issue and not related to hvac. 
Everything is dry today at the area of concern. 

Let client know that their duct work is not in great condition as all of the connections are poor and the ducts are not sealed and strapped up properly. Duct system will need to be redone in the future.
Inspected for possible hvac water leak. Client said roofer came out earlier today and said it was not a roof related issue. The water leak issue happened right during/after a major rain storm. 
Upon my inspection, found no evidence of any hvac equipment or ducts causing excessive water damage at the area of concern. 
I let client know they should wait for another rain storm and if the issue happens again that it is most likely a roofing issue and not related to hvac. 
Everything is dry today at the area of concern. 

Let client know that their duct work is not in great condition as all of the connections are poor and the ducts are not sealed and strapped up properly. Duct system will need to be redone in the future.
Michael A.
Michael A. Checked in
Inspected for possible hvac water leak. Client said roofer came out earlier today and said it was not a roof related issue. The water leak issue happened right during/after a major rain storm. Upon my inspection, found no evidence of any hvac equipment or ducts causing excessive water damage at the area of concern. I let client know they should wait for another rain storm and if the issue happens again that it is most likely a roofing issue and not related to hvac. Everything is dry today at the area of concern. Let client know that their duct work is not in great condition as all of the connections are poor and the ducts are not sealed and strapped up properly. Duct system will need to be redone in the future.
St. Petersburg, FL 33702
On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Performed first maintenance. Pressures good. Temp split good. Electrical checked good. Unit cooling at this time. Recommend to perform chemical cleaning on system of drain problem persists.
On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Performed first maintenance. Pressures good. Temp split good. Electrical checked good. Unit cooling at this time. Recommend to perform chemical cleaning on system of drain problem persists.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Performed first maintenance. Pressures good. Temp split good. Electrical checked good. Unit cooling at this time. Recommend to perform chemical cleaning on system of drain problem persists.
St. Petersburg, FL 33702
Reason for call:
No cool 

Equipment
R22 3 ton nordyne 
Vertical Ahu 
Condneser out back 

Summary:
Found system critically low on refrigerant. With r22 being fazed out I don't have access to the refrigerant. System replacement is homeowners best option. 
Homeowner wants to wait for his wife to go on vacation to replace system. She leaves n August for a month he plan to call back in at that point.
Reason for call:
No cool 

Equipment
R22 3 ton nordyne 
Vertical Ahu 
Condneser out back 

Summary:
Found system critically low on refrigerant. With r22 being fazed out I don't have access to the refrigerant. System replacement is homeowners best option. 
Homeowner wants to wait for his wife to go on vacation to replace system. She leaves n August for a month he plan to call back in at that point.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Equipment R22 3 ton nordyne Vertical Ahu Condneser out back Summary: Found system critically low on refrigerant. With r22 being fazed out I don't have access to the refrigerant. System replacement is homeowners best option. Homeowner wants to wait for his wife to go on vacation to replace system. She leaves n August for a month he plan to call back in at that point.
St. Petersburg, FL 33703
Upon arrival, I began by checking the main system. The temperature differential measured 23°F, which is within the optimal operating range. I inspected the electrical components and found them to be functioning properly with no signs of overamping. The refrigerant cycle was operating within manufacturer specifications. I then performed a drain line treatment and cleaned the condenser coil.

Next, I inspected the second system. The temperature differential measured 20°F, which is also within the normal operating range. The electrical components were functioning properly with no issues, and the refrigerant cycle was healthy. I completed a drain line cleaning, condenser coil cleaning, and a full air handler inspection.

At this time, both systems are operating properly and performing as expected. If you have any questions or concerns, please don’t hesitate to reach out. Thank you for choosing Airbros, and have a great day!
Upon arrival, I began by checking the main system. The temperature differential measured 23°F, which is within the optimal operating range. I inspected the electrical components and found them to be functioning properly with no signs of overamping. The refrigerant cycle was operating within manufacturer specifications. I then performed a drain line treatment and cleaned the condenser coil.

Next, I inspected the second system. The temperature differential measured 20°F, which is also within the normal operating range. The electrical components were functioning properly with no issues, and the refrigerant cycle was healthy. I completed a drain line cleaning, condenser coil cleaning, and a full air handler inspection.

At this time, both systems are operating properly and performing as expected. If you have any questions or concerns, please don’t hesitate to reach out. Thank you for choosing Airbros, and have a great day!
Ace m.
Ace m. Checked in
Upon arrival, I began by checking the main system. The temperature differential measured 23°F, which is within the optimal operating range. I inspected the electrical components and found them to be functioning properly with no signs of overamping. The refrigerant cycle was operating within manufacturer specifications. I then performed a drain line treatment and cleaned the condenser coil. Next, I inspected the second system. The temperature differential measured 20°F, which is also within the normal operating range. The electrical components were functioning properly with no issues, and the refrigerant cycle was healthy. I completed a drain line cleaning, condenser coil cleaning, and a full air handler inspection. At this time, both systems are operating properly and performing as expected. If you have any questions or concerns, please don’t hesitate to reach out. Thank you for choosing Airbros, and have a great day!
St. Petersburg, FL 33701
Drain line clogged. 
Cleaned and treated drain line and condensate pump. 
System is cooling at this time with 20° split. 
Power went out at this home while client was out of town. Checked electrical components and found not major issues at this time.
Drain line clogged. 
Cleaned and treated drain line and condensate pump. 
System is cooling at this time with 20° split. 
Power went out at this home while client was out of town. Checked electrical components and found not major issues at this time.
Michael A.
Michael A. Checked in
Drain line clogged. Cleaned and treated drain line and condensate pump. System is cooling at this time with 20° split. Power went out at this home while client was out of town. Checked electrical components and found not major issues at this time.
St. Petersburg, FL 33703
Upon my inspection, found system completely out of refrigerant. Performed leak search and found leak on liquid refrigerant line in attic. Made repair and charged system with 12lbs refrigerant. Strapped up lineset to prevent a similar leak in the future. System is cooling with proper pressures and 23° temperature split.
Upon my inspection, found system completely out of refrigerant. Performed leak search and found leak on liquid refrigerant line in attic. Made repair and charged system with 12lbs refrigerant. Strapped up lineset to prevent a similar leak in the future. System is cooling with proper pressures and 23° temperature split.
Michael A.
Michael A. Checked in
Upon my inspection, found system completely out of refrigerant. Performed leak search and found leak on liquid refrigerant line in attic. Made repair and charged system with 12lbs refrigerant. Strapped up lineset to prevent a similar leak in the future. System is cooling with proper pressures and 23° temperature split.
St. Petersburg, FL 33704
Client states system is not keeping up with temperature all of the sudden. 
Client replaced capacitor and condenser fan motor last week. 
This system is 13 years old and in poor condition. 
Evaporator coils are dirty/corroded/and very rusted. Drain line and primary drain pan are clogged up. Condenser fan motor is undersized at 1/6hp instead of factory 1/5hp. Fan blades are also mounted improperly low. 

Today we performed a drain cleaning and treatment on system. Adjusted fan blades. 

System is cooling with a 23° temperature split. 

System is doing the best it can considering its condition and age. I let client know not to expect too much out of this system and recommended full replacement. 
Sending quote for full replacement.
Client states system is not keeping up with temperature all of the sudden. 
Client replaced capacitor and condenser fan motor last week. 
This system is 13 years old and in poor condition. 
Evaporator coils are dirty/corroded/and very rusted. Drain line and primary drain pan are clogged up. Condenser fan motor is undersized at 1/6hp instead of factory 1/5hp. Fan blades are also mounted improperly low. 

Today we performed a drain cleaning and treatment on system. Adjusted fan blades. 

System is cooling with a 23° temperature split. 

System is doing the best it can considering its condition and age. I let client know not to expect too much out of this system and recommended full replacement. 
Sending quote for full replacement.
Michael A.
Michael A. Checked in
Client states system is not keeping up with temperature all of the sudden. Client replaced capacitor and condenser fan motor last week. This system is 13 years old and in poor condition. Evaporator coils are dirty/corroded/and very rusted. Drain line and primary drain pan are clogged up. Condenser fan motor is undersized at 1/6hp instead of factory 1/5hp. Fan blades are also mounted improperly low. Today we performed a drain cleaning and treatment on system. Adjusted fan blades. System is cooling with a 23° temperature split. System is doing the best it can considering its condition and age. I let client know not to expect too much out of this system and recommended full replacement. Sending quote for full replacement.
St. Petersburg, FL 33709
Found inadequate ductwork for guest bedrooms. Will need to enlarge ducts and mixing boxes to allow more flow to bedrooms. Will submit estimate.
Found inadequate ductwork for guest bedrooms. Will need to enlarge ducts and mixing boxes to allow more flow to bedrooms. Will submit estimate.
Justin G.
Justin G. Checked in
Found inadequate ductwork for guest bedrooms. Will need to enlarge ducts and mixing boxes to allow more flow to bedrooms. Will submit estimate.
St. Petersburg, FL 33703
How do I know if my AC needs repair or full replacement?

Our technicians inspect the full system — age, refrigerant type, corrosion, and repair history — and give you an honest recommendation. If a repair makes sense, we'll fix it. If the unit is beyond its useful life, we'll walk you through replacement options with no pressure.

Are your technicians background-checked and licensed?

Yes. Every Air Bros technician is background-checked, factory-trained, and works under our state HVAC license (#CAC1820499) and electrical license (#EC13015085).

What parts of St. Petersburg do you serve?

We serve all of St. Petersburg, including Downtown, Historic Kenwood, Old Northeast, Snell Isle, Crescent Lake, Shore Acres, and Coquina Key, plus Seminole, Largo, Pinellas Park, and the surrounding beach communities.

Do you offer same-day AC repair in St. Petersburg?

Yes. We offer 24/7 emergency AC repair with same-day service throughout St. Petersburg and the surrounding Pinellas County area.

Is Air Bros a local St. Petersburg company, or a franchise?

Air Bros is 100% locally owned and operated, headquartered in the Shore Acres neighborhood of St. Petersburg. We're not a franchise — every technician is a direct employee, not a subcontractor.

Contact the Bros You Know Today!

Gravity Forms Pagination Must be Steps