The Best AC Repair in St. Petersburg, FL — From Technicians Your Neighbors Already Trust

When your AC quits in the middle of a St. Pete summer, you don't want a stranger in an unmarked van. You want a technician your neighbors already know and trust. Air Bros Air Conditioning & Electrical has been fixing air conditioners in St. Petersburg since 2020, but our roots run deeper — founder Ricky Orta grew up learning the trade from his father and has been a licensed HVAC contractor since 2006. That local, hands-on experience is why homeowners from Historic Kenwood to Snell Isle call us the best AC repair company in St. Petersburg.

We're headquartered right here in the Shore Acres neighborhood, so when you call, you're not routed to a call center — you're talking to the same local team that services your street.

Call us at 727-217-6148 or contact us online today for all of your HVAC, indoor air quality and electrical needs.

Meet the technicians who service St. Petersburg

What to expect when we show up

Calling a repair company you've never used before shouldn't feel like a gamble. Here's exactly how an Air Bros service call goes, every time.

You'll get a heads-up before we arrive, then a uniformed technician in a marked Air Bros vehicle shows up in the window we promised. We diagnose the whole system — not just the obvious symptom — then explain what we found and what your options are before any work starts. You approve the price up front, we make the repair, and we don't leave until we've confirmed the system is cooling the way it should.

Every technician is a background-checked, drug-tested Air Bros employee — never a subcontractor — and each one is trained to service every major AC and heat pump brand. It's the kind of consistency you can only get from a local team that answers to its own name.

And if something isn't right? Our 100% satisfaction guarantee means we make it right.

Signs you need AC repair

St. Petersburg's heat and humidity push air conditioners harder than almost anywhere else in the country. Call for AC repair if you notice:

  • Warm air blowing from vents, or the system running constantly without cooling
  • Water pooling around your air handler (a common issue in St. Pete's older homes with attic-run drain lines)
  • Musty odors or visible mold near vents — a sign of a clogged condensate line or dirty coil
  • Rising humidity indoors despite the AC running
  • Short cycling, tripped breakers, or a system that won't turn on at all

Our technicians diagnose the full system on every call — refrigerant charge, temperature split, electrical connections, and drain line — so you get a real fix, not a temporary patch.

Comprehensive HVAC Services in St. Petersburg

We offer a full range of heating and cooling services to keep your St. Petersburg, FL, home comfortable year-round:

  • Air Conditioning: From AC repair and AC installation to routine maintenance, we ensure your cooling system keeps you comfortable during those hot Florida summers. We offer same-day service for AC emergencies, so you never have to suffer in the heat.
  • Heating: Stay warm and cozy in the winter with our comprehensive heating services. We repair and install all types of heating systems, including furnaces and heat pumps, and offer preventative maintenance to keep your system running efficiently.
  • Indoor Air Quality: Improve your indoor air quality with our dehumidifier and UV light installation services. We'll help you control excess humidity and eliminate airborne contaminants, creating a healthier home environment.
  • Ductwork: Ensure optimal airflow and energy efficiency with our ductwork repair and installation services. We can address leaks and damage, and design a system that's perfect for your home.
  • Pool Heater Services: Extend your swim season with our pool heater installation and repair services.
  • Electrical Services: From outlet and switch replacements to ceiling fan installations to whole-house surge protector installations, we have the experts to handle your electrical service needs.

Our experienced technicians are skilled in all aspects of HVAC service and are dedicated to providing top-quality workmanship and customer care.

Why Choose Air Bros?

  • Local Expertise: We understand the unique climate challenges of St. Petersburg.
  • Fast and Reliable Service: We offer same-day service for AC emergencies and prioritize prompt service for all your HVAC needs.
  • Experienced Technicians: Our team is highly trained and experienced in all aspects of HVAC service.
  • Upfront Pricing: We provide transparent pricing with no hidden costs.
  • Customer Satisfaction Guaranteed: Your comfort and satisfaction are our top priorities.

Contact Air Bros Today!

Whether you need emergency AC repair, a new heating system installation, or any other HVAC service, Air Bros is here to help. Contact us today for a free consultation or to schedule a service appointment. We're proud to be your trusted HVAC partner in St. Petersburg!

Call us at 727-217-6148 or contact us online today!

Recent Jobs and Reviews in St. Petersburg, FL

St. Petersburg, FL at a glance

Air Bros Air Conditioning & Electrical has completed 25 jobs in St. Petersburg, FL between July 2026 and August 2026.

The most recent job was on August 4, 2026.

Air Bros Air Conditioning & Electrical has completed 1,919 jobs in St. Petersburg, FL in the last 12 months. The first job there was in December 2024.

Job Locations and Reviews

Diagnostic 
-failed outdoor 40/5 capacitor on compressor side 
-outdoor coils impacted with dirt/debris 
-system 1.5lb low 410a

Inspected air handler and coils 

Inspected float and verified no water in system 

Checked filter 

Verified Thermosat operations 

Further Notes 
-ducts not sealed properly 
-2.5T system for 1050sf
-single pain windows 

Will assess ductwork in winter during maintenance 

Scope of work 
-replace outdoor capacitor 
-clean Condenser coils 
-add 1.5lb 410a

System is 6 years of age. Will monitor pressures in case of leak in system 

Unit is currently operating within manufacture specifications 
10% off with membership
Diagnostic 
-failed outdoor 40/5 capacitor on compressor side 
-outdoor coils impacted with dirt/debris 
-system 1.5lb low 410a

Inspected air handler and coils 

Inspected float and verified no water in system 

Checked filter 

Verified Thermosat operations 

Further Notes 
-ducts not sealed properly 
-2.5T system for 1050sf
-single pain windows 

Will assess ductwork in winter during maintenance 

Scope of work 
-replace outdoor capacitor 
-clean Condenser coils 
-add 1.5lb 410a

System is 6 years of age. Will monitor pressures in case of leak in system 

Unit is currently operating within manufacture specifications 
10% off with membership
Nathan A.
Nathan A. Checked in
Diagnostic -failed outdoor 40/5 capacitor on compressor side -outdoor coils impacted with dirt/debris -system 1.5lb low 410a Inspected air handler and coils Inspected float and verified no water in system Checked filter Verified Thermosat operations Further Notes -ducts not sealed properly -2.5T system for 1050sf -single pain windows Will assess ductwork in winter during maintenance Scope of work -replace outdoor capacitor -clean Condenser coils -add 1.5lb 410a System is 6 years of age. Will monitor pressures in case of leak in system Unit is currently operating within manufacture specifications 10% off with membership
St. Petersburg, FL 33703
Called tech support to diagnose e1 error code for 4 head mini split. Tech support diagnosed bad main board for outdoor unit. Will submit estimate for replacement. Unit is cooling to the best of its ability at this time.
Called tech support to diagnose e1 error code for 4 head mini split. Tech support diagnosed bad main board for outdoor unit. Will submit estimate for replacement. Unit is cooling to the best of its ability at this time.
Justin G.
Justin G. Checked in
Called tech support to diagnose e1 error code for 4 head mini split. Tech support diagnosed bad main board for outdoor unit. Will submit estimate for replacement. Unit is cooling to the best of its ability at this time.
St. Petersburg, FL 33705
Martin W.
Martin W. Checked in
Recover Refrigerant Remove Low Voltage to Air Handler Remove High Voltage to Air Handler Remove Supply Plenum Cut Refrigerant Lines Cut Drain Lines Install New Free Draw Wall Mounting Bracket Install Wall Mounting Anchors Rebuild Supply Plenum Insulate Refrigerant Lines Install High/Low Voltage Weld Refrigerant Lines Install Drain Line Pressure Test System Vacuum System Verify System Operations 3 Year Workmanship Warranty
St. Petersburg, FL 33702
Full system tuneup 

Unit is operating within manufacture specifications 

Notes
-fixed attic trim
-insulated air handler penetration points
Full system tuneup 

Unit is operating within manufacture specifications 

Notes
-fixed attic trim
-insulated air handler penetration points
Nathan A.
Nathan A. Checked in
Full system tuneup Unit is operating within manufacture specifications Notes -fixed attic trim -insulated air handler penetration points
St. Petersburg, FL 33702
Remove and replace 14” return duct connect duct board trunk lines in attic. Tax and labor included. Refund $50 from service fee for moving forward with repair.
Remove and replace 14” return duct connect duct board trunk lines in attic. Tax and labor included. Refund $50 from service fee for moving forward with repair.
Justin G.
Justin G. Checked in
Remove and replace 14” return duct connect duct board trunk lines in attic. Tax and labor included. Refund $50 from service fee for moving forward with repair.
St. Petersburg, FL 33703
Upon arrival, I began by checking the temperature split between the supply and return air, which measured 18°F, indicating normal system performance. I then inspected the electrical components and found all equipment operating within manufacturer specifications, with no components over-amping. The refrigerant cycle was checked and is operating properly.

As part of today’s maintenance, I performed a complete drain line treatment, cleaned the drain pan, cleaned the condenser coil, and completed a full air handler inspection. The system is operating properly at this time.

Homeowner noticed around eight months ago that the condenser was making a loud noise upon further diagnostic the compressor is happening internal weakness, and it is causing a loud noise. And situations like this when everything else looks good besides the internal parts of the compressor the only option is replacing the part to get rid of the noise. I provided a quote for the homeowner. Please reach out if you’d like
Upon arrival, I began by checking the temperature split between the supply and return air, which measured 18°F, indicating normal system performance. I then inspected the electrical components and found all equipment operating within manufacturer specifications, with no components over-amping. The refrigerant cycle was checked and is operating properly.

As part of today’s maintenance, I performed a complete drain line treatment, cleaned the drain pan, cleaned the condenser coil, and completed a full air handler inspection. The system is operating properly at this time.

Homeowner noticed around eight months ago that the condenser was making a loud noise upon further diagnostic the compressor is happening internal weakness, and it is causing a loud noise. And situations like this when everything else looks good besides the internal parts of the compressor the only option is replacing the part to get rid of the noise. I provided a quote for the homeowner. Please reach out if you’d like
Ace m.
Ace m. Checked in
Upon arrival, I began by checking the temperature split between the supply and return air, which measured 18°F, indicating normal system performance. I then inspected the electrical components and found all equipment operating within manufacturer specifications, with no components over-amping. The refrigerant cycle was checked and is operating properly. As part of today’s maintenance, I performed a complete drain line treatment, cleaned the drain pan, cleaned the condenser coil, and completed a full air handler inspection. The system is operating properly at this time. Homeowner noticed around eight months ago that the condenser was making a loud noise upon further diagnostic the compressor is happening internal weakness, and it is causing a loud noise. And situations like this when everything else looks good besides the internal parts of the compressor the only option is replacing the part to get rid of the noise. I provided a quote for the homeowner. Please reach out if you’d like
St. Petersburg, FL 33716

Client stated that they had to vacuum out drain line last week. 
System is 13-14 years old. 
Performed tuneup on system. Cleaned and treated drain line in primary drain pan. Clean condenser coils. Checked amp draws checked capacitor checked contactor. Blower wheel is impacted with debris and bacterial growth. Large amount of bacterial growth inside air handler. Visible rodent damage on the drain line insulation and duct work. System does not have a primary float switch installed. System has a 17° temperature split. 
Let client know they need to change their filter asap. 

We highly recommend installation of a primary float safety switch. 
Client would like to leave the system as is and get through the rest of this year leaving it alone. Client does not want to be on a Maitenence plan for biannual Maitenence at this time. Client will call of there’s any cooling issues they notice. 

System is cooling ok and draining at this time

Client stated that they had to vacuum out drain line last week. 
System is 13-14 years old. 
Performed tuneup on system. Cleaned and treated drain line in primary drain pan. Clean condenser coils. Checked amp draws checked capacitor checked contactor. Blower wheel is impacted with debris and bacterial growth. Large amount of bacterial growth inside air handler. Visible rodent damage on the drain line insulation and duct work. System does not have a primary float switch installed. System has a 17° temperature split. 
Let client know they need to change their filter asap. 

We highly recommend installation of a primary float safety switch. 
Client would like to leave the system as is and get through the rest of this year leaving it alone. Client does not want to be on a Maitenence plan for biannual Maitenence at this time. Client will call of there’s any cooling issues they notice. 

System is cooling ok and draining at this time
Michael A.
Michael A. Checked in
Client stated that they had to vacuum out drain line last week. System is 13-14 years old. Performed tuneup on system. Cleaned and treated drain line in primary drain pan. Clean condenser coils. Checked amp draws checked capacitor checked contactor. Blower wheel is impacted with debris and bacterial growth. Large amount of bacterial growth inside air handler. Visible rodent damage on the drain line insulation and duct work. System does not have a primary float switch installed. System has a 17° temperature split. Let client know they need to change their filter asap. We highly recommend installation of a primary float safety switch. Client would like to leave the system as is and get through the rest of this year leaving it alone. Client does not want to be on a Maitenence plan for biannual Maitenence at this time. Client will call of there’s any cooling issues they notice. System is cooling ok and draining at this time
St. Petersburg, FL 33703
Reason for call:
Water leak

Summary: found water damage coming from old metal duct work. Duct work can date 50+ years old. Duct work need to be replaced for issue to be solved. Quoted new duct work.
Reason for call:
Water leak

Summary: found water damage coming from old metal duct work. Duct work can date 50+ years old. Duct work need to be replaced for issue to be solved. Quoted new duct work.
Corbin C.
Corbin C. Checked in
Reason for call: Water leak Summary: found water damage coming from old metal duct work. Duct work can date 50+ years old. Duct work need to be replaced for issue to be solved. Quoted new duct work.
St. Petersburg, FL 33703
Reason for call:
Mini split no cool 

Summary:
Found compressor not operating properly found major communication faults. Found 20+ codes on remote. 
Spent time with tech support to diagnose faulty compressor and faulty inverter board. Both are intermittently failing. 

Both will need to be replace and both indoor and outdoor unit need to be cleaned.
Reason for call:
Mini split no cool 

Summary:
Found compressor not operating properly found major communication faults. Found 20+ codes on remote. 
Spent time with tech support to diagnose faulty compressor and faulty inverter board. Both are intermittently failing. 

Both will need to be replace and both indoor and outdoor unit need to be cleaned.
Corbin C.
Corbin C. Checked in
Reason for call: Mini split no cool Summary: Found compressor not operating properly found major communication faults. Found 20+ codes on remote. Spent time with tech support to diagnose faulty compressor and faulty inverter board. Both are intermittently failing. Both will need to be replace and both indoor and outdoor unit need to be cleaned.
St. Petersburg, FL 33701
Upon arrival, the air handler was turning on, but the condenser was not upon further diagnostic. The capacitor was dead, upon replacing the capacitor the system turned on and I had a 20° temperature difference, refrigerant cycle was healthy with no issues and electrical was also well. Homeowner wants to schedule a maintenance in December, if you have any questions, please reach out.
Upon arrival, the air handler was turning on, but the condenser was not upon further diagnostic. The capacitor was dead, upon replacing the capacitor the system turned on and I had a 20° temperature difference, refrigerant cycle was healthy with no issues and electrical was also well. Homeowner wants to schedule a maintenance in December, if you have any questions, please reach out.
Ace m.
Ace m. Checked in
Upon arrival, the air handler was turning on, but the condenser was not upon further diagnostic. The capacitor was dead, upon replacing the capacitor the system turned on and I had a 20° temperature difference, refrigerant cycle was healthy with no issues and electrical was also well. Homeowner wants to schedule a maintenance in December, if you have any questions, please reach out.
St. Petersburg, FL 33701
Ruud 15.2 seer2 3 ton heat pump split system with 5kw heater
Hurricane pad
Anchor condenser 
Primary float switch
Adjustable stand
Clear drain
Pressure test line set
Pull vacuum on lineset and equipment 
Thermostat 
1” filter rack
Remove existing equipment 
Connect to existing ducts and electrical 
Seal unit to code
Tax labor and permit included
10 year parts warranty 
3 year labor warranty 
0% for 18 months financing included
Ruud 15.2 seer2 3 ton heat pump split system with 5kw heater
Hurricane pad
Anchor condenser 
Primary float switch
Adjustable stand
Clear drain
Pressure test line set
Pull vacuum on lineset and equipment 
Thermostat 
1” filter rack
Remove existing equipment 
Connect to existing ducts and electrical 
Seal unit to code
Tax labor and permit included
10 year parts warranty 
3 year labor warranty 
0% for 18 months financing included
Kyle K.
Kyle K. Checked in
Ruud 15.2 seer2 3 ton heat pump split system with 5kw heater Hurricane pad Anchor condenser Primary float switch Adjustable stand Clear drain Pressure test line set Pull vacuum on lineset and equipment Thermostat 1” filter rack Remove existing equipment Connect to existing ducts and electrical Seal unit to code Tax labor and permit included 10 year parts warranty 3 year labor warranty 0% for 18 months financing included
St. Petersburg, FL 33701
4 Head Single Condenser (Left Side of Home)

Home owners state error code E1 has happened. Upon arrival system is working within manufacture specifications. Explained it issue happens again to not reset system. Verified pressures and temp splits. Inspected board and tightened connections 

2 Head Single Condenser (Right Side of Home)

Surge protector was not operable. Fixed surge and verified operations.
4 Head Single Condenser (Left Side of Home)

Home owners state error code E1 has happened. Upon arrival system is working within manufacture specifications. Explained it issue happens again to not reset system. Verified pressures and temp splits. Inspected board and tightened connections 

2 Head Single Condenser (Right Side of Home)

Surge protector was not operable. Fixed surge and verified operations.
Nathan A.
Nathan A. Checked in
4 Head Single Condenser (Left Side of Home) Home owners state error code E1 has happened. Upon arrival system is working within manufacture specifications. Explained it issue happens again to not reset system. Verified pressures and temp splits. Inspected board and tightened connections 2 Head Single Condenser (Right Side of Home) Surge protector was not operable. Fixed surge and verified operations.
St. Petersburg, FL 33705
Install wireless transponder for condenser to receive proper signal from air handler for cooling operation. Start and test. Verify operation. Possible further diagnostic after parts installed. Tax and labor included. Parts will take a couple days to receive.
Installed transponder. Unit cooling properly with 20* temperature split.
Install wireless transponder for condenser to receive proper signal from air handler for cooling operation. Start and test. Verify operation. Possible further diagnostic after parts installed. Tax and labor included. Parts will take a couple days to receive.
Installed transponder. Unit cooling properly with 20* temperature split.
Justin G.
Justin G. Checked in
Install wireless transponder for condenser to receive proper signal from air handler for cooling operation. Start and test. Verify operation. Possible further diagnostic after parts installed. Tax and labor included. Parts will take a couple days to receive. Installed transponder. Unit cooling properly with 20* temperature split.
St. Petersburg, FL 33715
Reason for call
No cool 

Equipment:
2019 Icp 
Horizontal in attic
Condenser behind home 

Summary:
On arrival found secondary pan full of water. Confirmed drain lien was clogged. Found missing primary float switch. 
Confirmed proper temperatures and operation of equipment. 

Solution:
Flush and clean drain line. 
Add primary float switch to bring system to code. 

Changed Safety wiring to r to cut power to stat. 
Operation was restored to equipment.
Reason for call
No cool 

Equipment:
2019 Icp 
Horizontal in attic
Condenser behind home 

Summary:
On arrival found secondary pan full of water. Confirmed drain lien was clogged. Found missing primary float switch. 
Confirmed proper temperatures and operation of equipment. 

Solution:
Flush and clean drain line. 
Add primary float switch to bring system to code. 

Changed Safety wiring to r to cut power to stat. 
Operation was restored to equipment.
Corbin C.
Corbin C. Checked in
Reason for call No cool Equipment: 2019 Icp Horizontal in attic Condenser behind home Summary: On arrival found secondary pan full of water. Confirmed drain lien was clogged. Found missing primary float switch. Confirmed proper temperatures and operation of equipment. Solution: Flush and clean drain line. Add primary float switch to bring system to code. Changed Safety wiring to r to cut power to stat. Operation was restored to equipment.
St. Petersburg, FL 33713
Upon arrival, the homeowner stated that she returned home on Saturday and found water on the floor near the air handler, which is located above the water heater. I began my diagnostic by checking the system’s temperature split and measured a 16°F difference. I then checked the refrigerant circuit and found both the suction and liquid line pressures to be low. Further diagnostics confirmed a minor refrigerant leak within the system.

To investigate the reported water leak, I performed a drain line test by pouring approximately one gallon of water through the drain. The drain flowed properly with no signs of restriction or backup. I allowed the system to operate for approximately one hour while monitoring for leaks. During this time, I found no water leaking from the air handler, the float switch remained dry, and there was no condensation dripping from the ductwork or any HVAC component.

Upon further inspection of the surrounding area, I found visible water stains and signs of leaking
Upon arrival, the homeowner stated that she returned home on Saturday and found water on the floor near the air handler, which is located above the water heater. I began my diagnostic by checking the system’s temperature split and measured a 16°F difference. I then checked the refrigerant circuit and found both the suction and liquid line pressures to be low. Further diagnostics confirmed a minor refrigerant leak within the system.

To investigate the reported water leak, I performed a drain line test by pouring approximately one gallon of water through the drain. The drain flowed properly with no signs of restriction or backup. I allowed the system to operate for approximately one hour while monitoring for leaks. During this time, I found no water leaking from the air handler, the float switch remained dry, and there was no condensation dripping from the ductwork or any HVAC component.

Upon further inspection of the surrounding area, I found visible water stains and signs of leaking
Ace m.
Ace m. Checked in
Upon arrival, the homeowner stated that she returned home on Saturday and found water on the floor near the air handler, which is located above the water heater. I began my diagnostic by checking the system’s temperature split and measured a 16°F difference. I then checked the refrigerant circuit and found both the suction and liquid line pressures to be low. Further diagnostics confirmed a minor refrigerant leak within the system. To investigate the reported water leak, I performed a drain line test by pouring approximately one gallon of water through the drain. The drain flowed properly with no signs of restriction or backup. I allowed the system to operate for approximately one hour while monitoring for leaks. During this time, I found no water leaking from the air handler, the float switch remained dry, and there was no condensation dripping from the ductwork or any HVAC component. Upon further inspection of the surrounding area, I found visible water stains and signs of leaking
St. Petersburg, FL 33710
Upon arrival, I found the system completely shut down. I inspected the air handler and found the secondary drain pan full of water, which had activated the float switch and shut the system off. I temporarily bypassed the float switch to perform a full diagnostic.

The system is operating properly with an 18°F temperature split. Refrigerant pressures are within the normal operating range, with no signs of leaks or restrictions. Mechanically, the equipment is functioning properly.

I tested the condensate drain line and found it to be clear with no restrictions. The water is not backing up from the drain line; instead, it is collecting beneath the air handler and draining into the secondary pan, eventually triggering the float switch.

Upon further inspection, I found several gaps in the return plenum that are allowing warm, humid attic air to be drawn into the system. When this humid air comes into contact with the cold air handler and duct surfaces, excessive condensation can form, con
Upon arrival, I found the system completely shut down. I inspected the air handler and found the secondary drain pan full of water, which had activated the float switch and shut the system off. I temporarily bypassed the float switch to perform a full diagnostic.

The system is operating properly with an 18°F temperature split. Refrigerant pressures are within the normal operating range, with no signs of leaks or restrictions. Mechanically, the equipment is functioning properly.

I tested the condensate drain line and found it to be clear with no restrictions. The water is not backing up from the drain line; instead, it is collecting beneath the air handler and draining into the secondary pan, eventually triggering the float switch.

Upon further inspection, I found several gaps in the return plenum that are allowing warm, humid attic air to be drawn into the system. When this humid air comes into contact with the cold air handler and duct surfaces, excessive condensation can form, con
Ace m.
Ace m. Checked in
Upon arrival, I found the system completely shut down. I inspected the air handler and found the secondary drain pan full of water, which had activated the float switch and shut the system off. I temporarily bypassed the float switch to perform a full diagnostic. The system is operating properly with an 18°F temperature split. Refrigerant pressures are within the normal operating range, with no signs of leaks or restrictions. Mechanically, the equipment is functioning properly. I tested the condensate drain line and found it to be clear with no restrictions. The water is not backing up from the drain line; instead, it is collecting beneath the air handler and draining into the secondary pan, eventually triggering the float switch. Upon further inspection, I found several gaps in the return plenum that are allowing warm, humid attic air to be drawn into the system. When this humid air comes into contact with the cold air handler and duct surfaces, excessive condensation can form, con
St. Petersburg, FL 33703
St. Petersburg, FL - On arrival found unit not cooling due to collapsed return duct. Will return Tuesday to replace duct. Unit does not cooling due at this time.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to collapsed return duct. Will return Tuesday to replace duct. Unit does not cooling due at this time.
St. Petersburg, FL 33703
Upon arrival, the homeowner stated that the system was unable to cool the home below 80°F. During my initial inspection, I found the thermostat set to 81°F. With the homeowner’s permission, I lowered the thermostat to 78°F, which is the temperature they normally prefer.

I allowed the system to operate for approximately one hour while monitoring its performance. Throughout the testing period, I repeatedly checked the refrigerant pressures, operating temperatures, and overall system performance. All readings remained within normal manufacturer specifications, and the system maintained a healthy 19°F temperature split between the supply and return air, indicating that it is cooling properly. No mechanical or refrigerant-related issues were found at this time.

I discussed the benefits of our maintenance plan with the homeowner. They were interested but would like some time to think it over and stated they will reach out if they decide to enroll.

If you have any questions, please don’t h
Upon arrival, the homeowner stated that the system was unable to cool the home below 80°F. During my initial inspection, I found the thermostat set to 81°F. With the homeowner’s permission, I lowered the thermostat to 78°F, which is the temperature they normally prefer.

I allowed the system to operate for approximately one hour while monitoring its performance. Throughout the testing period, I repeatedly checked the refrigerant pressures, operating temperatures, and overall system performance. All readings remained within normal manufacturer specifications, and the system maintained a healthy 19°F temperature split between the supply and return air, indicating that it is cooling properly. No mechanical or refrigerant-related issues were found at this time.

I discussed the benefits of our maintenance plan with the homeowner. They were interested but would like some time to think it over and stated they will reach out if they decide to enroll.

If you have any questions, please don’t h
Ace m.
Ace m. Checked in
Upon arrival, the homeowner stated that the system was unable to cool the home below 80°F. During my initial inspection, I found the thermostat set to 81°F. With the homeowner’s permission, I lowered the thermostat to 78°F, which is the temperature they normally prefer. I allowed the system to operate for approximately one hour while monitoring its performance. Throughout the testing period, I repeatedly checked the refrigerant pressures, operating temperatures, and overall system performance. All readings remained within normal manufacturer specifications, and the system maintained a healthy 19°F temperature split between the supply and return air, indicating that it is cooling properly. No mechanical or refrigerant-related issues were found at this time. I discussed the benefits of our maintenance plan with the homeowner. They were interested but would like some time to think it over and stated they will reach out if they decide to enroll. If you have any questions, please don’t h
St. Petersburg, FL 33714
On arrival found unit not cooling due to outdoor fan motor not running. Found capacitor not wired properly. Fixed wires and tested. Unit started cooling. Found pressures not actuate due to worn compressor. Will submit estimate for compressor replacement. Unit has 10* split and cooling to the best of its ability.
On arrival found unit not cooling due to outdoor fan motor not running. Found capacitor not wired properly. Fixed wires and tested. Unit started cooling. Found pressures not actuate due to worn compressor. Will submit estimate for compressor replacement. Unit has 10* split and cooling to the best of its ability.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to outdoor fan motor not running. Found capacitor not wired properly. Fixed wires and tested. Unit started cooling. Found pressures not actuate due to worn compressor. Will submit estimate for compressor replacement. Unit has 10* split and cooling to the best of its ability.
St. Petersburg, FL 33713
Install Single 9K BTU Head (Bedroom Facing Bathroom Area)
Install Single 12K BTU Head (Above TV Common Area)
Remote Operated 
Install Wall Mounting Bracket
Hurricane Tie Down Straps
Vibration Pads
New Refrigerant Lines
New Communication Wire
Install Hard Pipe PVC Drain
Install Exterior Line Covers
Install Multi Zone Outdoor Condenser (Back Side of Home)
Seal Penetration Points 
Pressure Test Systems 
Vacuum Systems 
Charge Systems 
UV Rated Outdoor Insulation 
Refrigerant Locking Caps
Electrical to Panel/Breaker (Run Through Attic)
Outdoor Surge Protection 
New Outdoor Electrical Whip
New Outdoor Electrical Disconnect 
12 Year Parts Warranty 
3 Year Labor Warranty 

*Cap ducts in addition area (3 supply ducts)
*Complimentary tuneup on main AC system
Install Single 9K BTU Head (Bedroom Facing Bathroom Area)
Install Single 12K BTU Head (Above TV Common Area)
Remote Operated 
Install Wall Mounting Bracket
Hurricane Tie Down Straps
Vibration Pads
New Refrigerant Lines
New Communication Wire
Install Hard Pipe PVC Drain
Install Exterior Line Covers
Install Multi Zone Outdoor Condenser (Back Side of Home)
Seal Penetration Points 
Pressure Test Systems 
Vacuum Systems 
Charge Systems 
UV Rated Outdoor Insulation 
Refrigerant Locking Caps
Electrical to Panel/Breaker (Run Through Attic)
Outdoor Surge Protection 
New Outdoor Electrical Whip
New Outdoor Electrical Disconnect 
12 Year Parts Warranty 
3 Year Labor Warranty 

*Cap ducts in addition area (3 supply ducts)
*Complimentary tuneup on main AC system
Kyle K.
Kyle K. Checked in
Install Single 9K BTU Head (Bedroom Facing Bathroom Area) Install Single 12K BTU Head (Above TV Common Area) Remote Operated Install Wall Mounting Bracket Hurricane Tie Down Straps Vibration Pads New Refrigerant Lines New Communication Wire Install Hard Pipe PVC Drain Install Exterior Line Covers Install Multi Zone Outdoor Condenser (Back Side of Home) Seal Penetration Points Pressure Test Systems Vacuum Systems Charge Systems UV Rated Outdoor Insulation Refrigerant Locking Caps Electrical to Panel/Breaker (Run Through Attic) Outdoor Surge Protection New Outdoor Electrical Whip New Outdoor Electrical Disconnect 12 Year Parts Warranty 3 Year Labor Warranty *Cap ducts in addition area (3 supply ducts) *Complimentary tuneup on main AC system
St. Petersburg, FL 33704
On arrival found blown fuse causing unit not to cool. Observed shorted wire on roof causing issue. Recommend to replace contactor and run new thermostat wire on roof. Replaced parts. Start and test. Unit cooling at this time.
On arrival found blown fuse causing unit not to cool. Observed shorted wire on roof causing issue. Recommend to replace contactor and run new thermostat wire on roof. Replaced parts. Start and test. Unit cooling at this time.
Justin G.
Justin G. Checked in
On arrival found blown fuse causing unit not to cool. Observed shorted wire on roof causing issue. Recommend to replace contactor and run new thermostat wire on roof. Replaced parts. Start and test. Unit cooling at this time.
St. Petersburg, FL 33705
Upon arrival, I began by checking the temperature split between the supply and return air, which measured 21°F, indicating normal system performance. I then inspected the electrical components and found all equipment operating within manufacturer specifications, with no components over-amping. The refrigerant cycle was checked and is operating properly.

As part of today’s maintenance, I performed a complete drain line treatment, cleaned the drain pan, cleaned the condenser coil, and completed a full air handler inspection. The system is operating properly at this time.

If you have any questions or concerns, please don’t hesitate to reach out. Thank you for your business, and have a great day
Upon arrival, I began by checking the temperature split between the supply and return air, which measured 21°F, indicating normal system performance. I then inspected the electrical components and found all equipment operating within manufacturer specifications, with no components over-amping. The refrigerant cycle was checked and is operating properly.

As part of today’s maintenance, I performed a complete drain line treatment, cleaned the drain pan, cleaned the condenser coil, and completed a full air handler inspection. The system is operating properly at this time.

If you have any questions or concerns, please don’t hesitate to reach out. Thank you for your business, and have a great day
Ace m.
Ace m. Checked in
Upon arrival, I began by checking the temperature split between the supply and return air, which measured 21°F, indicating normal system performance. I then inspected the electrical components and found all equipment operating within manufacturer specifications, with no components over-amping. The refrigerant cycle was checked and is operating properly. As part of today’s maintenance, I performed a complete drain line treatment, cleaned the drain pan, cleaned the condenser coil, and completed a full air handler inspection. The system is operating properly at this time. If you have any questions or concerns, please don’t hesitate to reach out. Thank you for your business, and have a great day
St. Petersburg, FL 33713
Justin G.
Justin G. Checked in
Replace section of thermostat wire from air handler and replaced fuse. Start and test. Unit cooling properly at this time.
St. Petersburg, FL 33704
Diagnostic 
-clogged condensate pump and drain line 
-drain pan and safety full of water 

Scope of work 
-clean drain line and drain pan 
-clean condensate pump 
-prime pump and drain line 
-add pan tablets to help with buildup 
-changed filter 

Verified all system operations and drainage
Diagnostic 
-clogged condensate pump and drain line 
-drain pan and safety full of water 

Scope of work 
-clean drain line and drain pan 
-clean condensate pump 
-prime pump and drain line 
-add pan tablets to help with buildup 
-changed filter 

Verified all system operations and drainage
Nathan A.
Nathan A. Checked in
Diagnostic -clogged condensate pump and drain line -drain pan and safety full of water Scope of work -clean drain line and drain pan -clean condensate pump -prime pump and drain line -add pan tablets to help with buildup -changed filter Verified all system operations and drainage
St. Petersburg, FL 33710
Ace m.
Ace m. Checked in
Upon arrival, I began the maintenance by performing a complete system diagnostic. First, I checked the temperature split between the supply and return air and recorded an 18°F temperature difference, which is within the normal operating range. Next, I inspected the electrical components. The compressor and blower motor are operating within manufacturer specifications, with no signs of over-amperage. I then checked the refrigerant cycle and found the operating pressures to be within the proper range, with no indications of refrigerant leaks or restrictions. As part of today’s maintenance, I cleaned the condensate drain pan, treated and cleaned the drain line to help prevent future clogs, cleaned the condenser coil, and performed a light cleaning of the evaporator coil. Overall, the system is operating properly and is in good condition with no issues found at this time. The homeowner is preparing to move out of the property, and the HVAC system is ready for the new buyers. If you have
St. Petersburg, FL 33703
How do I know if my AC needs repair or full replacement?

Our technicians inspect the full system — age, refrigerant type, corrosion, and repair history — and give you an honest recommendation. If a repair makes sense, we'll fix it. If the unit is beyond its useful life, we'll walk you through replacement options with no pressure.

Are your technicians background-checked and licensed?

Yes. Every Air Bros technician is background-checked, factory-trained, and works under our state HVAC license (#CAC1820499) and electrical license (#EC13015085).

What parts of St. Petersburg do you serve?

We serve all of St. Petersburg, including Downtown, Historic Kenwood, Old Northeast, Snell Isle, Crescent Lake, Shore Acres, and Coquina Key, plus Seminole, Largo, Pinellas Park, and the surrounding beach communities.

Do you offer same-day AC repair in St. Petersburg?

Yes. We offer 24/7 emergency AC repair with same-day service throughout St. Petersburg and the surrounding Pinellas County area.

Is Air Bros a local St. Petersburg company, or a franchise?

Air Bros is 100% locally owned and operated, headquartered in the Shore Acres neighborhood of St. Petersburg. We're not a franchise — every technician is a direct employee, not a subcontractor.

Contact the Bros You Know Today!