Air Conditioning, Heating & Electrical Repair in Seminole, FL

Air Bros has deep roots on this side of Pinellas County. Our shop sits right on 131st Street, so when your air conditioner quits on a 95-degree afternoon, help isn't coming from a call center two counties over — it's a licensed technician a few minutes down the road. We've worked on homes from the Seminole Springs and Lake Seminole neighborhoods out toward the barrier-island beaches, and we know what the heat, the salt air, and the summer storms do to a comfort system around here.

We handle the whole house, too: air conditioning, heating, indoor air quality, and the electrical work that ties it all together. One team, one number, day or night.

Call us at 727-217-6148 or reach out online — same-day service is available, and we're open around the clock.

The HVAC & Electrical Challenges We See Most in Seminole

Living a stone's throw from the Gulf is the whole point of being here. It's also hard on equipment. The problems we get called for in this part of Pinellas tend to fall into a few familiar buckets.

Salt Air Eats Coastal Systems Alive

Homes near the beaches catch a steady dose of salt-laden air, and it doesn't stay outside. It settles on condenser coils, corrodes fan motors, and works its way into outdoor electrical connections far faster than it would inland. We routinely find pitted contactors, rusted cabinets, and weak capacitors on systems that are barely a few years old. Regular coil flushing, sealed connections, and corrosion-rated parts make a real difference, which is why a maintenance plan pays for itself quickly near the water.

Humidity That Never Really Lets Up

Our subtropical air carries moisture twelve months a year, and a huge share of the "no cool" calls we run trace right back to it. A clogged condensate drain. A slime-coated drain pan. Biological growth on a blower wheel or evaporator coil that chokes airflow and pushes humidity back into the house. Left alone, that moisture turns into musty air and water damage. We clear and treat drains as part of every tune-up, and for homes that fight stubborn humidity we install whole-home dehumidifiers and UV air purification to keep coils and ducts clean.

Storms, Lightning, and Power Surges

Tampa Bay sits in one of the most lightning-prone corners of the country, and a single summer storm can send a surge through your home that fries a capacitor, a control board, or an entire electrical panel. We see the aftermath all season. Protecting a system here means more than a good warranty — it means whole-home surge protection at the panel and at the equipment. And because hurricane season is a fact of life, every system we install gets properly anchored with a code-rated pad and hurricane tie-down straps so your condenser stays put when the wind picks up.

Aging Equipment and Strained Electrical

A lot of homes around here still run older systems on their original panels and wiring. We've opened up units to find aluminum branch wiring, breakers running hot under load, and circuits that were never sized for today's demands. As neighbors add EV chargers, pool heaters, and higher-capacity AC systems, the electrical side has to keep pace — or it becomes the thing that fails next. Our licensed electricians handle panel upgrades, wiring repairs, surge protection, and EV charger installation so the whole house can keep up with the way you actually live.

What We Do for Homes in the Area

We offer a full range of comfort and electrical services, all under one roof:

When something can't wait, we run 24/7 emergency service, too.

Why Neighbors Call Air Bros

  • We're local, not a franchise. We live and work in the same climate you do, and we understand what coastal Pinellas does to a system.
  • Day-or-night, same-day service. When you need us, we show up — fast.
  • Honest, upfront pricing. You'll know the cost before we start. No mystery fees, no pressure.
  • Trained, licensed technicians. HVAC and electrical work done right the first time. (License #CAC1820499 · License #EC13015085)
  • 100% satisfaction, guaranteed. Your comfort is the whole job.

Get Comfortable Again

Whether it's an emergency AC repair, a new system, a surge-protection upgrade, or a pool heater that's ready for summer, we're ready to help. Call the Bros You Know and let's get your home back to comfortable.

Call 727-217-6148 or request service online today.

Recent Jobs and Reviews in Seminole, FL

Seminole, FL at a glance

Air Bros Air Conditioning & Electrical has completed 25 jobs in Seminole, FL between August 2026 and September 2026.

The most recent job was on September 15, 2026.

Job Locations and Reviews

Kyle K.
Kyle K. Checked in
Replace supply plenum Replace return plenums Reconnect and seal all duct work to plenums Replace 30 ft 8in flex with micro bacterial Install remi halo led in new supply plenum Patch any small blemishes in attic on mixing boxes
Seminole, FL 33772
Justin G.
Justin G. Checked in
Replace blower board
Seminole, FL 33776
On arrival found unit not cooling due to bad compressor. Will submit estimates for repair and replacement options. Unit does not cool.
On arrival found unit not cooling due to bad compressor. Will submit estimates for repair and replacement options. Unit does not cool.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to bad compressor. Will submit estimates for repair and replacement options. Unit does not cool.
Seminole, FL 33776
Reason for call:
Duct work and equipment inspection

Summary:
Performed inspection of entirety of System. 
Found that the fan was set to on. Informed tenants that they need to have the fan set to auto.
Inspected ductwork to find majority of ductwork Had Ronan damage this was causing condensation and biological growth within the ductwork.
Found ductwork buried inside insulation

Informed homeowner of concerns provided estimate for full ductwork replacement.
Reason for call:
Duct work and equipment inspection

Summary:
Performed inspection of entirety of System. 
Found that the fan was set to on. Informed tenants that they need to have the fan set to auto.
Inspected ductwork to find majority of ductwork Had Ronan damage this was causing condensation and biological growth within the ductwork.
Found ductwork buried inside insulation

Informed homeowner of concerns provided estimate for full ductwork replacement.
Corbin C.
Corbin C. Checked in
Reason for call: Duct work and equipment inspection Summary: Performed inspection of entirety of System. Found that the fan was set to on. Informed tenants that they need to have the fan set to auto. Inspected ductwork to find majority of ductwork Had Ronan damage this was causing condensation and biological growth within the ductwork. Found ductwork buried inside insulation Informed homeowner of concerns provided estimate for full ductwork replacement.
Seminole, FL 33778
Ruud 3 ton 14.3 seer2 heat pump split system with 5kw heater
Use existing stand for condenser
Thermostat 
Anchor condenser
Aux pan
Float switches
Remove existing equipment 
Connect to existing ducts and electrical 
Seal unit to code
Tax labor and permit included 
10 year parts warranty 
3 year labor warranty 
Check price only
Ruud 3 ton 14.3 seer2 heat pump split system with 5kw heater
Use existing stand for condenser
Thermostat 
Anchor condenser
Aux pan
Float switches
Remove existing equipment 
Connect to existing ducts and electrical 
Seal unit to code
Tax labor and permit included 
10 year parts warranty 
3 year labor warranty 
Check price only
Kyle K.
Kyle K. Checked in
Ruud 3 ton 14.3 seer2 heat pump split system with 5kw heater Use existing stand for condenser Thermostat Anchor condenser Aux pan Float switches Remove existing equipment Connect to existing ducts and electrical Seal unit to code Tax labor and permit included 10 year parts warranty 3 year labor warranty Check price only
Seminole, FL 33776
Reason for call:
Tune up 

Summary:
Completed tune up to find operation of equipment within manufacturing specifications. 
Confirmed proper temperatures. 
Confirmed proper amp draws. 
Confirmed proper capacitor readings. 
Flushed drain line and drain pan. 
Flushed indoor and outdoor coils. 
Filters have been maintained properly. 

Solution:
Informed client about membership plan
Reason for call:
Tune up 

Summary:
Completed tune up to find operation of equipment within manufacturing specifications. 
Confirmed proper temperatures. 
Confirmed proper amp draws. 
Confirmed proper capacitor readings. 
Flushed drain line and drain pan. 
Flushed indoor and outdoor coils. 
Filters have been maintained properly. 

Solution:
Informed client about membership plan
Corbin C.
Corbin C. Checked in
Reason for call: Tune up Summary: Completed tune up to find operation of equipment within manufacturing specifications. Confirmed proper temperatures. Confirmed proper amp draws. Confirmed proper capacitor readings. Flushed drain line and drain pan. Flushed indoor and outdoor coils. Filters have been maintained properly. Solution: Informed client about membership plan
Seminole, FL 33776
Reason for call:
Tune up 

Summary:
Completed tune up to find operation of equipment within manufacturing specifications. 
Flushed both indoor and outdoor coils. 
Flushed drain line and pan. 
Confirmed proper temperatures. 
Found weak capacitor and buzzing contactor. 
Unit is in good condition. 
Blower, coils are very clean. 


Solution:
Replace dual capacitor 
Replace contactor 
1 year parts and labor warranty
Reason for call:
Tune up 

Summary:
Completed tune up to find operation of equipment within manufacturing specifications. 
Flushed both indoor and outdoor coils. 
Flushed drain line and pan. 
Confirmed proper temperatures. 
Found weak capacitor and buzzing contactor. 
Unit is in good condition. 
Blower, coils are very clean. 


Solution:
Replace dual capacitor 
Replace contactor 
1 year parts and labor warranty
Corbin C.
Corbin C. Checked in
Reason for call: Tune up Summary: Completed tune up to find operation of equipment within manufacturing specifications. Flushed both indoor and outdoor coils. Flushed drain line and pan. Confirmed proper temperatures. Found weak capacitor and buzzing contactor. Unit is in good condition. Blower, coils are very clean. Solution: Replace dual capacitor Replace contactor 1 year parts and labor warranty
Seminole, FL 33772
On arrival found unit leaking due to failed float switch and clogged drain. Replaced float switch and cleared. Added chemical to pan. Added refrigerant back to factory specs on unit. Unit is cooling properly at this time.
On arrival found unit leaking due to failed float switch and clogged drain. Replaced float switch and cleared. Added chemical to pan. Added refrigerant back to factory specs on unit. Unit is cooling properly at this time.
Justin G.
Justin G. Checked in
On arrival found unit leaking due to failed float switch and clogged drain. Replaced float switch and cleared. Added chemical to pan. Added refrigerant back to factory specs on unit. Unit is cooling properly at this time.
Seminole, FL 33777
On arrival found unit not cooling due to bad blower board. By passed board to test. Blower is operational. Will submit estimate to replace board. Blower will run continuously until board is replaced. Unit cooling.
On arrival found unit not cooling due to bad blower board. By passed board to test. Blower is operational. Will submit estimate to replace board. Blower will run continuously until board is replaced. Unit cooling.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to bad blower board. By passed board to test. Blower is operational. Will submit estimate to replace board. Blower will run continuously until board is replaced. Unit cooling.
Seminole, FL 33776
System not cooling due to bad capacitor. Replaced capacitor and started system. System is cooling at this time with good amp draws, and a good temperature split. 
Lifetime warranty on capacitor installed.
System not cooling due to bad capacitor. Replaced capacitor and started system. System is cooling at this time with good amp draws, and a good temperature split. 
Lifetime warranty on capacitor installed.
Michael A.
Michael A. Checked in
System not cooling due to bad capacitor. Replaced capacitor and started system. System is cooling at this time with good amp draws, and a good temperature split. Lifetime warranty on capacitor installed.
Seminole, FL 33772
Client states system not cooling properly. They had to clean their drain line. 

Upon my inspection, found system cooling with a 20° temperature split. Good amp draws. Capacitor is within range. 

Ecobee thermostat was giving them a high humidity alert for the past 2 days. Found humidity was off set by about 9°. Made adjustment. 
While looking over everything. Noticed compressor turned off. Found the condensate pump was extremely clogged up and potentially causing the safety float switch to short cycle the compressor. 
Cleaned and treated condensate pump and restarted system. If issue persists, the compressor may be faulty. 

Upon my inspection, found system cooling with a 20° temperature split. Good amp draws. Capacitor is within range. 

Inspected duct work and found severely poor duct work design and installation. Client would like a quote to replace all duct work. Will provide a quote this weekend.
Client states system not cooling properly. They had to clean their drain line. 

Upon my inspection, found system cooling with a 20° temperature split. Good amp draws. Capacitor is within range. 

Ecobee thermostat was giving them a high humidity alert for the past 2 days. Found humidity was off set by about 9°. Made adjustment. 
While looking over everything. Noticed compressor turned off. Found the condensate pump was extremely clogged up and potentially causing the safety float switch to short cycle the compressor. 
Cleaned and treated condensate pump and restarted system. If issue persists, the compressor may be faulty. 

Upon my inspection, found system cooling with a 20° temperature split. Good amp draws. Capacitor is within range. 

Inspected duct work and found severely poor duct work design and installation. Client would like a quote to replace all duct work. Will provide a quote this weekend.
Michael A.
Michael A. Checked in
Client states system not cooling properly. They had to clean their drain line. Upon my inspection, found system cooling with a 20° temperature split. Good amp draws. Capacitor is within range. Ecobee thermostat was giving them a high humidity alert for the past 2 days. Found humidity was off set by about 9°. Made adjustment. While looking over everything. Noticed compressor turned off. Found the condensate pump was extremely clogged up and potentially causing the safety float switch to short cycle the compressor. Cleaned and treated condensate pump and restarted system. If issue persists, the compressor may be faulty. Upon my inspection, found system cooling with a 20° temperature split. Good amp draws. Capacitor is within range. Inspected duct work and found severely poor duct work design and installation. Client would like a quote to replace all duct work. Will provide a quote this weekend.
Seminole, FL 33776
Reason for call:
No cool

Summary:
On arrival found compressor to have open windings. Failing to start.
Informed homeowner of his options he decided to replace unit
Install is for tomorrow, Saturday 9/5
Client is expecting a portable unit between 1-3 today
Homeowner signed up for membership
Reason for call:
No cool

Summary:
On arrival found compressor to have open windings. Failing to start.
Informed homeowner of his options he decided to replace unit
Install is for tomorrow, Saturday 9/5
Client is expecting a portable unit between 1-3 today
Homeowner signed up for membership
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: On arrival found compressor to have open windings. Failing to start. Informed homeowner of his options he decided to replace unit Install is for tomorrow, Saturday 9/5 Client is expecting a portable unit between 1-3 today Homeowner signed up for membership
Seminole, FL 33776
Install new ceiling fan and move the bedroom fan to the office 

Fan controllers were not pairing with the wall remotes fans are operational from the pull chains
Install new ceiling fan and move the bedroom fan to the office 

Fan controllers were not pairing with the wall remotes fans are operational from the pull chains
Griffin K.
Griffin K. Checked in
Install new ceiling fan and move the bedroom fan to the office Fan controllers were not pairing with the wall remotes fans are operational from the pull chains
Seminole, FL 33777
Seminole, FL - Inspected mini split for not cooling properly. Found very poor installation of mini split. Filter dryer installed in line with soft solder. Told client we are unable to make repairs due to install. Client declined full system replacement at this time.
Justin G.
Justin G. Checked in
Inspected mini split for not cooling properly. Found very poor installation of mini split. Filter dryer installed in line with soft solder. Told client we are unable to make repairs due to install. Client declined full system replacement at this time.
Seminole, FL 33772
Justin G.
Justin G. Checked in
Pull and clean blower wheel and evap coil. Replace stall primary float switch. Pull vacuum. Start and test. Perform maintenance on system. Tax and labor included.
Seminole, FL 33777
Upon arrival, the homeowner expressed concerns regarding the ductwork after noticing condensation on the ceiling. Upon inspection, I found that the condensation is originating from the original metal ductwork in the home. The ductwork is currently suspended improperly and is experiencing condensation, which is contributing to the moisture on the ceiling.

I discussed the findings with the homeowner and explained that the recommended long-term solution is to replace the existing metal ductwork with properly insulated flex ductwork to help prevent future condensation issues.

I also inspected the drain line and discussed its condition with the homeowner. The drain line is aged, and the homeowner expressed interest in replacing the existing trap as well as the interior and exterior portions of the drain line.

The homeowner would like a few days to consider the recommended repairs and requested that I follow up with her around the middle of the week.

If you have any questions, please fee
Upon arrival, the homeowner expressed concerns regarding the ductwork after noticing condensation on the ceiling. Upon inspection, I found that the condensation is originating from the original metal ductwork in the home. The ductwork is currently suspended improperly and is experiencing condensation, which is contributing to the moisture on the ceiling.

I discussed the findings with the homeowner and explained that the recommended long-term solution is to replace the existing metal ductwork with properly insulated flex ductwork to help prevent future condensation issues.

I also inspected the drain line and discussed its condition with the homeowner. The drain line is aged, and the homeowner expressed interest in replacing the existing trap as well as the interior and exterior portions of the drain line.

The homeowner would like a few days to consider the recommended repairs and requested that I follow up with her around the middle of the week.

If you have any questions, please fee
ihsan m.
ihsan m. Checked in
Upon arrival, the homeowner expressed concerns regarding the ductwork after noticing condensation on the ceiling. Upon inspection, I found that the condensation is originating from the original metal ductwork in the home. The ductwork is currently suspended improperly and is experiencing condensation, which is contributing to the moisture on the ceiling. I discussed the findings with the homeowner and explained that the recommended long-term solution is to replace the existing metal ductwork with properly insulated flex ductwork to help prevent future condensation issues. I also inspected the drain line and discussed its condition with the homeowner. The drain line is aged, and the homeowner expressed interest in replacing the existing trap as well as the interior and exterior portions of the drain line. The homeowner would like a few days to consider the recommended repairs and requested that I follow up with her around the middle of the week. If you have any questions, please fee
Seminole, FL 33772
Ricky O.
Ricky O. Checked in
Replaced relay for blower motor. System is running as of now. 16 years old sent client quote for replacement
Seminole, FL 33776
Seminole, FL - On arrival found unit not cooling due to bad contactor. Replaced part. Added refrigerant back to factory specs. Unit cooling. Will submit estimate for condenser coil replacement.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to bad contactor. Replaced part. Added refrigerant back to factory specs. Unit cooling. Will submit estimate for condenser coil replacement.
Seminole, FL 33772
On arrival found unit with impacted coil and blower causing airflow restriction. Unit is leaking water from dirty coil as well. Will return to perform proper cleaning on system. Made client aware of further diagnostic after cleanings are performed. Air handler and condenser are mixed matched.
On arrival found unit with impacted coil and blower causing airflow restriction. Unit is leaking water from dirty coil as well. Will return to perform proper cleaning on system. Made client aware of further diagnostic after cleanings are performed. Air handler and condenser are mixed matched.
Justin G.
Justin G. Checked in
On arrival found unit with impacted coil and blower causing airflow restriction. Unit is leaking water from dirty coil as well. Will return to perform proper cleaning on system. Made client aware of further diagnostic after cleanings are performed. Air handler and condenser are mixed matched.
Seminole, FL 33777
Ricky O.
Ricky O. Checked in
Found unit not working because incoming power from Duke not working. Not getting 230v. Client is calling duke
Seminole, FL 33777
Upon my inspection, found 1 condenser 3 head mini split system purchased from Amazon is poorly installed. 
Two head units are not mounted properly on the walls causing water issues as well as one head is falling off the wall. 
Found system freezing up due to low refrigerant. System has a refrigerant leak. 
We will not perform repairs on an Amazon system that was very poorly installed as it is a liability and we cannot guarantee anything. 

We are providing a quote for a full system replacement with professional installation practices and Name brand equipment from Mitsubishi that come with warranties. 

Systems should not be ran at this time. 

Will apply $95 service fee towards new system installation
Upon my inspection, found 1 condenser 3 head mini split system purchased from Amazon is poorly installed. 
Two head units are not mounted properly on the walls causing water issues as well as one head is falling off the wall. 
Found system freezing up due to low refrigerant. System has a refrigerant leak. 
We will not perform repairs on an Amazon system that was very poorly installed as it is a liability and we cannot guarantee anything. 

We are providing a quote for a full system replacement with professional installation practices and Name brand equipment from Mitsubishi that come with warranties. 

Systems should not be ran at this time. 

Will apply $95 service fee towards new system installation
Michael A.
Michael A. Checked in
Upon my inspection, found 1 condenser 3 head mini split system purchased from Amazon is poorly installed. Two head units are not mounted properly on the walls causing water issues as well as one head is falling off the wall. Found system freezing up due to low refrigerant. System has a refrigerant leak. We will not perform repairs on an Amazon system that was very poorly installed as it is a liability and we cannot guarantee anything. We are providing a quote for a full system replacement with professional installation practices and Name brand equipment from Mitsubishi that come with warranties. Systems should not be ran at this time. Will apply $95 service fee towards new system installation
Seminole, FL 33776
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on  compressor. Checked amp draw on fan motor. Checked capacitor is not within factory range. Inspected Contactar and found contactar has weak contacts. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.

Recommending replacing the capacitor and contactar. Sending quote for both. Also sending quote for our Maitenence plan which will apply 10% off for repairs.
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on  compressor. Checked amp draw on fan motor. Checked capacitor is not within factory range. Inspected Contactar and found contactar has weak contacts. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.

Recommending replacing the capacitor and contactar. Sending quote for both. Also sending quote for our Maitenence plan which will apply 10% off for repairs.
Michael A.
Michael A. Checked in
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is not within factory range. Inspected Contactar and found contactar has weak contacts. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. Recommending replacing the capacitor and contactar. Sending quote for both. Also sending quote for our Maitenence plan which will apply 10% off for repairs.
Seminole, FL 33777
Reason for call:
Return repair

Summary:
Replaced Evaporator coil on master bedroom zone. 
Completed repair to restore operation to equipment. 
Unit is cooling with a 20 degree split. 
Proper pressure.
Drain line operation is proper.
Reason for call:
Return repair

Summary:
Replaced Evaporator coil on master bedroom zone. 
Completed repair to restore operation to equipment. 
Unit is cooling with a 20 degree split. 
Proper pressure.
Drain line operation is proper.
Corbin C.
Corbin C. Checked in
Reason for call: Return repair Summary: Replaced Evaporator coil on master bedroom zone. Completed repair to restore operation to equipment. Unit is cooling with a 20 degree split. Proper pressure. Drain line operation is proper.
Seminole, FL 33772
11 Year Daikin System (Second Owner)

2.5T Downstairs (Vertical Closet)

Diagnostic 
-system low on refrigerant unit indicating leak (outdoor data tag panel indicates a dye test was performed a year ago, home owner states they were not able to trace leak)
-outdoor capacitor reading outside factory specifications 
-drain line has active water in float 

System has not been maintenance since last year 

Air Handler Further Notes 
-bacterial growth on back side of coils 
-bacterial growth inside air handler cabinet/blower wheel 

Outdoor Condenser Further Notes 
-outdoor coils impacted with debris 
-outdoor disconnect exposed (face plate missing)
-outdoor suction line lacking insulation 

Went over all issues with home owner. Offered leak search options and replacement options. Home owner would like to complete minimal repair and keep system going. 

Scope of work performed 
-cleared drain line 
-cleared drain pan & pan canals 
-added pan tablets and solution to help with further buildup
11 Year Daikin System (Second Owner)

2.5T Downstairs (Vertical Closet)

Diagnostic 
-system low on refrigerant unit indicating leak (outdoor data tag panel indicates a dye test was performed a year ago, home owner states they were not able to trace leak)
-outdoor capacitor reading outside factory specifications 
-drain line has active water in float 

System has not been maintenance since last year 

Air Handler Further Notes 
-bacterial growth on back side of coils 
-bacterial growth inside air handler cabinet/blower wheel 

Outdoor Condenser Further Notes 
-outdoor coils impacted with debris 
-outdoor disconnect exposed (face plate missing)
-outdoor suction line lacking insulation 

Went over all issues with home owner. Offered leak search options and replacement options. Home owner would like to complete minimal repair and keep system going. 

Scope of work performed 
-cleared drain line 
-cleared drain pan & pan canals 
-added pan tablets and solution to help with further buildup
Nathan A.
Nathan A. Checked in
11 Year Daikin System (Second Owner) 2.5T Downstairs (Vertical Closet) Diagnostic -system low on refrigerant unit indicating leak (outdoor data tag panel indicates a dye test was performed a year ago, home owner states they were not able to trace leak) -outdoor capacitor reading outside factory specifications -drain line has active water in float System has not been maintenance since last year Air Handler Further Notes -bacterial growth on back side of coils -bacterial growth inside air handler cabinet/blower wheel Outdoor Condenser Further Notes -outdoor coils impacted with debris -outdoor disconnect exposed (face plate missing) -outdoor suction line lacking insulation Went over all issues with home owner. Offered leak search options and replacement options. Home owner would like to complete minimal repair and keep system going. Scope of work performed -cleared drain line -cleared drain pan & pan canals -added pan tablets and solution to help with further buildup
Seminole, FL 33776
Griffin K.
Griffin K. Checked in
-5" duct run -Connect directly to back of main plenum -Run as close to new addition as possible -New boot and grille -Strap and seal run
Seminole, FL 33772

Contact the Bros You Know Today!

Gravity Forms Pagination Must be Steps