Your Hometown HVAC Experts
Air Bros Air Conditioning & Heating is deeply rooted in the Seminole, FL, community. We're not just your HVAC service provider; we're your neighbors. We understand the importance of reliable and efficient HVAC systems in Florida's climate, and we're dedicated to keeping your Seminole home comfortable year-round. Whether you live in a cozy bungalow near the beaches or a spacious family home in the heart of Seminole, our team is here to provide top-notch service with a personal touch.
Call us at 727-217-6148 or contact us online for help in Seminole, FL.
Comprehensive HVAC Services in Seminole:
We offer a full range of heating and cooling services tailored to the needs of Seminole residents that provide:
- Year-Round Comfort: From scorching summers to chilly winter nights, we've got your comfort covered. Our expert technicians provide comprehensive AC and heating services, including repair, installation, and maintenance for all makes and models. We'll keep your home at the perfect temperature, no matter the season.
- Easy Breathing: Enjoy clean, healthy air in your Largo home. Our indoor air quality solutions, including dehumidifiers and UV light air purifiers, help reduce allergens, control humidity, and create a healthier living environment for you and your family.
- Optimized Airflow: Maximize your comfort and energy efficiency with our professional ductwork services. We'll ensure proper airflow, prevent energy waste, and improve the overall performance of your HVAC system.
Why Choose Air Bros in Seminole?
- Your Seminole Neighbors: We're not just an HVAC company; we're part of the Seminole community. We understand the local climate and the importance of reliable HVAC systems for your home.
- Prompt and Dependable Service: When you need us, we'll be there. We offer same-day service for AC emergencies and prioritize quick response times for all your HVAC needs.
- Expert Technicians: Our team is highly trained and experienced in all aspects of HVAC service, ensuring you receive top-quality workmanship every time.
- Honest and Transparent Pricing: We believe in upfront pricing with no hidden fees or surprises. You'll always know exactly what to expect.
- Your Comfort is Our Priority: We're dedicated to ensuring your complete satisfaction with our services and your home comfort.
Contact Air Bros Today!
Whether you need emergency AC repair, a new heating system installation, or any other HVAC service, Air Bros is here to help. Contact us today for a free consultation or to schedule a service appointment. We're proud to be your trusted HVAC partner in Seminole!
Call us at 727-217-6148 or contact us online for help in Seminole, FL.
Recent Jobs and Reviews in Seminole, FL
Job Locations and Reviews
Upon my inspection, I found the condenser fan motor was not engaging. After further diagnosis, I found the motor start run capacitor was weak and no longer functional. Replaced capacitor. Amp draws on start up and running are great on both the compressor and fan motor. Owner was notified that the brakered disconnect is faulty and needs to be replaced as it does not cut full power to the condenser unit. Complimentary condenser coil cleaning included. System pressures are good. System is cooling. Discussed with Jim that the duct work going to the back room of the house can be re routed for better air flow by moving it further down away from the air handler on the supply plenum box.
Return to complete repairs. Also found capacitor reading very weak. Swapped capacitor at no charge. Verified system is cooling. Replaced filter as well.
Ruud 1.5 ton heat pump split system w/ 5 kw heater 15.2 seer 2 10 year parts warranty 3 year labor warranty -Permit -Hurricane pad -Hurricane tiedowns -Uv rated armorflex -Flush drain -Move air handler down 6” for better accessibility -Connect to existing duct system -Float switch -Thermostat -Filter rack (optional) -100% satisfaction guarantee
Replace outdoor electrical disconnect Verified operations
Add return duct to master bedroom Insulate drain line in garage
Home owner states unit is overflowing through vents. Found drain line heavily backed up. Cleared drain line and pan. System has not been maintenance for some time. Would recommend clearing coil plugs if issue persist. Verified system was cooling and draining. Pancake unit located in ceiling. Condenser requires extension ladder to roof. Would recommend cleaning coil plugs and tray.
I arrived onsite and found system freezing due to clogged filter, lack of return air and low on charge. I removed filter and thawed out system. I added refrigerant and inspected ductwork. Recommend replacing ducts in winter but for now need to add a return to master bedroom. Sending seperate quote for that. Unit is cooling best as possible right now.
Ruud 18 seer invertor 10 year parts warranty 3 year labor warranty -Hurricane pad -Surge protection -Hurricane straps -Hurricane tiedowns -Adjustable stand -4” media filter -Condensate pump -Receptacle in room -Vertical drain pan -Safeties -New disconnect for air handler -Box in supply plenum
Arrived onsite and found air handler panels etc had been taken apart by home owner. Disconnect on air handler had also been pulled. I plugged in and started system. Checked full operation and found no issues. Pressure and temps good. Cap good and unit is draining. Taped up small air leak on top of supply plenum. Advised client if system goes down again don’t touch anything and call us we will come back no service fee.
On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Added chemical to help prevent growth. Unit cooling at this time.
Return repair- evaporator coil pull and clean Homeowner mentioned the system stopped cooling again before this appointment. Runs but blows non cool air. Found weak capacitor 16/35 mfd. Replaced capacitor during maintenance. Performed full system maintenance. Cleaned drain line. Informed homeowner that the UV system they have is no longer working. Sent replacement estimate as blower motor does have microbial growth. Pumped down all refrigerant into compressor Cut out evaporator coil Performed full chemical cleaning on evaporator coil and outdoor condenser coil Reinstalled and brazed in evaporator coil Pressure tested with nitrogen Pulled vacuum under 500 microns Released refrigerant and restarted system in cooling Advised homeowners if system shows the same systems again, not to change thermostat or turn off breakers until service call.
No cool Homeowner states system has not kept up with desired temp during afternoon heat. Noticed this issue today. Checked refrigerant pressures and air temp split in cooling. System is working properly but not running efficiently due to dirty evaporator and condenser coils. Recommend homeowner has maintenance done and evaporator coil pull and clean. Condenser coil cleaning will be included at time of evaporator cleaning+ first maintenance. Signed up for maintenance membership today. Office will call tomorrow to schedule return visit. Recommended filter - pleated air filter MERV 8, buy on amazon
Install New Air Handler New Supply Plenum Install Air Handler UV System Install New Outdoor Condenser New Filter Drier Install Thermostat (Locking Screen) Thermostat Wire Included Primary Float Safety Switch Secondary Float Safety Switch Install Horizontal Drain Pan UV Rated Outdoor Insulation Refrigerant Locking Caps Flush Existing Refrigerant Lines Flush Drain Line 4” Hurricane Pad Hurricane Tie Down Straps Vacuum System Seal Supply/Return Plenums Remove Current Equipment Permitting 10 Year Parts Warranty 3 Year Labor Warranty 100% Satisfaction *Complimentary Duct Sanitation (495$ Value)
Older R22 system running low on refrigerant. Air handler motor is intermittently failing. Home owner states it will turn on and off. Unit will need a supply plenum and primary float safety switch. Recommend replacing motor but not able to fill system due to being r22. Bacterial growth on blower wheel/assembly.
No cool In cooling mode compressor will not start. Capacitor is weak- installed new capacitor, compressor still doesn’t start. Tested compressor ohms and checked continuity to ground. No reading on locked rotor amps. cooled compressor with water. Installed hard start kit- no change. Condenser is 2004 R22 and air handler is 2017 410A. R22 is no longer available and 410A systems are no longer available. The only repair option is full system replacement. Homeowner does not want system replacement estimate at this time. System is not cooling, homeowner is aware that i left the condenser breaker OFF.
On arrival found unit not cooling due to weak capacitor. Replaced part. Start and test. Pressures good. Temp split good. Unit cooling properly at this time.
No cool Upon arrival found thermostat set to off. Homeowner says system stopped cooling this morning and blows warm air. Set thermostat to cool, system runs as normal. While standing at condenser i noticed the fan motor stopped running for a few seconds then than back on. Monitored refrigerant pressures and air temp for 30 mins. System is slightly low on refrigerant but not enough to stop the system from cooking the home. Recommend replacement fan motor as it seems to be having intermittent issues. Homeowner would like to move forward with outdoor fan motor replacement. Also found weak capacitor and sent estimate for replacement. Signed up for maintenance membership.
Ruud 15 seer heat pump 10 year parts warranty 3 year labor warranty Quote is good until May 16 5 year 0% interest financing 2 stage system -Permit -Hurricane pad -Hurricane tiedowns -Electrical whip -Breakers -Coffin box with legs -Duct plenum on return up to ceiling as per code -Flush drain and Reinsulate -Thermostat -Insulate all exposed copper -Connect to existing supply plenum -100% satisfaction guarantee
Precision tune up Checked refrigerant pressures and air temp split. Tested capacitor and cleaned electrical cabinet. Cleaned and treated drain pan/ line. Filter is dirty but homeowner does not have a replacement at this time. Tested float switch. Air handler interior is clean. Removed and cleaned return grille. Homeowner is not interested in membership.
System freezing over due to air handler coils being impacted with debris. Recommend coil pull and clean. Checked starting components. Checked pressures and temp splits
Replaced bad contactor and capacitor. 5% police discount. Checked full system operation. No further issues.
Return visit- replace capacitor came back to change out weak 30+5 mfd capacitor. Tested system function after repair. Advised homeowner we will give him a call when it’s time for his next maintenance.
On arrival found unit not on. Set thermostat. Found probable cause for condenser not running is weak capacitor. Replaced part and made wire repair. Start and test. Flushed drain. Pressures good. Temp split good. Unit is cooling at this time.
On arrival found both systems with clogged drains causing units not to cool. Cleared pan and drains. Pressures good. Temp split good. Both systems are cooling properly at this time.
Upon arrival found thermostat set to off. Set system in cooling and outdoor unit is not starting. Found dead capacitor. Additionally, float switch is tripped because of clogged drain line. Homeowner decided to move forward with these repairs today. Replaced capacitor and flushed and treated drain line. Cleared water from float switch and made sure system is draining on its own. Checked refrigerant pressures and air temp.