financing Special Offers Call Us Book Online

Largo, FL

air-bros-team-with-truck

Largo, FL, Home Comfort Solutions

As a locally owned and operated company, Air Bros is proud to be a part of the Largo community. We understand the challenges that Florida's heat and humidity can bring, and we're dedicated to providing our neighbors with reliable HVAC solutions to keep their homes comfortable year-round. Whether you're just steps from the Gulf or nestled in a quiet neighborhood, you can count on Air Bros for top-notch service and personalized solutions.

Call us at 727-217-6148 or contact us online.

Why Choose Air Bros in Largo?

  • Local Expertise: We're familiar with the unique climate challenges of Largo and the specific needs of its residents.
  • Customer-Focused Approach: Your comfort and satisfaction are our top priorities. We listen to your concerns, answer your questions, and provide tailored solutions that fit your needs and budget.
  • Experienced and Certified Technicians: Our team consists of highly skilled and certified technicians with extensive experience in all aspects of HVAC service. You can trust us to get the job done right.
  • Fast and Reliable Service: We know that HVAC issues can be disruptive. That's why we prioritize prompt and reliable service, offering same-day service for AC emergencies and quick response times for all your HVAC needs.
  • Upfront Pricing: We believe in transparency and honesty. You'll always receive upfront pricing with no hidden costs or surprises.

Comprehensive HVAC Services in Largo, FL

  • Complete Comfort Solutions: We're your one-stop shop for heating and cooling in Largo. Whether you need AC repair on a scorching summer day or a new furnace installed before winter arrives, our expert technicians have you covered. We service all makes and models, ensuring your home stays comfortable no matter the season.
  • Healthy Indoor Air: We go beyond temperature control to ensure the air you breathe is clean and healthy. Our indoor air quality solutions, including dehumidifiers and UV light air purifiers, help control humidity, eliminate allergens, and create a healthier home environment for you and your family.
  • Efficient Airflow: Your ductwork plays a crucial role in your home's comfort and energy efficiency. Our professional ductwork services ensure optimal airflow, prevent energy waste, and improve the overall performance of your HVAC system.

Beyond the Basics

  • Pool Heater Services: Enjoy your pool year-round with our pool heater installation and repair services.
  • Electrical Services: We can handle your electrical needs, including outlet and switch replacements, ceiling fan installations, and whole-house surge protector installations.

Contact Air Bros Today!

We're your trusted HVAC partner in Largo. Contact us today for a free consultation or to schedule a service appointment. Experience the Air Bros difference!

Call us at 727-217-6148 or contact us online.

Recent Jobs and Reviews in Largo, FL

Job Locations and Reviews

Installation of Air Purifier
Rinsed condenser coils
Vacuumed drain lines
Installation of Air Purifier
Rinsed condenser coils
Vacuumed drain lines
Michael A.
Michael A. Checked in
Installation of Air Purifier Rinsed condenser coils Vacuumed drain lines
Largo, FL 33777
Michael A.
Michael A. Checked in
Upon my inspection, found client had replaced their capacitor. Checked drain line and found clogged drain line and tripped safety switch. Recommended a drain line cleaning and treatment. Client does not want drain cleaning at this time. Found thermostat was not connected properly when it was removed prior to my arrival. Put thermostat on all the way and system started up. System is cooling with good amp draws and 18° temp split.
Largo, FL 33771
Ricky O.
Ricky O. Checked in
Cleaned drain line. Unit is cooling at this time. Clogged drain Service fee
Largo, FL 33778
Justin G.
Justin G. Checked in
replace boards, sensors, Eev and stepper motor Unit has 22* split
Largo, FL 33773
On arrival found unit not cooling properly. Found Eev not functioning properly. Unit has multiple error codes relating to sensors and boards. Found afc board not communicating. Recommended to replace boards, sensors, Eev and stepper motor. Will further diagnose system when parts are replaced.
On arrival found unit not cooling properly. Found Eev not functioning properly. Unit has multiple error codes relating to sensors and boards. Found afc board not communicating. Recommended to replace boards, sensors, Eev and stepper motor. Will further diagnose system when parts are replaced.
Justin G.
Justin G. Checked in
On arrival found unit not cooling properly. Found Eev not functioning properly. Unit has multiple error codes relating to sensors and boards. Found afc board not communicating. Recommended to replace boards, sensors, Eev and stepper motor. Will further diagnose system when parts are replaced.
Largo, FL 33773
3.5 ton 15 seer heat pump
10 year parts warranty
5 year labor warranty 
-Hurricane pad
-Hurricane tiedowns 
-Run drain from under home to exit home
-Connect to existing ducts
-WiFi stat
-Drain pan
-Safety switches
-UV light
-Breakers as needed
-Drain line clean out 
-Insulate piping in attic
3.5 ton 15 seer heat pump
10 year parts warranty
5 year labor warranty 
-Hurricane pad
-Hurricane tiedowns 
-Run drain from under home to exit home
-Connect to existing ducts
-WiFi stat
-Drain pan
-Safety switches
-UV light
-Breakers as needed
-Drain line clean out 
-Insulate piping in attic
Martin W.
Martin W. Checked in
3.5 ton 15 seer heat pump 10 year parts warranty 5 year labor warranty -Hurricane pad -Hurricane tiedowns -Run drain from under home to exit home -Connect to existing ducts -WiFi stat -Drain pan -Safety switches -UV light -Breakers as needed -Drain line clean out -Insulate piping in attic
Largo, FL 33770
Michael A.
Michael A. Checked in
Upon my inspection, I found a bad capacitor. I replaced the capacitor and checked amp draw on the compressor and fan motor and everything looks good. System is cooling properly at the moment.
Largo, FL 33777
Michael A.
Michael A. Checked in
Upon my arrival, clients main concern was the cleanliness of the air handler unit and making sure that the last company was honest about their diagnosis and trying to sell them a new system. I made sure the Client knew that they had options and a new system is not necessarily required. I sent a quote for repair/ Cleaning of the system to completely reset all of the growth and prevent future growth. I also sent a quote for a new system replacement incase the client would like to invest in a new system with 3 year labor warranty and 10 year parts warranty. All information for the quotes are listed in the summary sections and if there are any questions please don’t hesitate to ask. System is cooling at this time
Largo, FL 33773
Largo, FL - Install a gfci outlet and sleeve exposed wire in conduit
Bailey M.
Bailey M. Checked in
Install a gfci outlet and sleeve exposed wire in conduit
Largo, FL 33773
Upon arrival home owner states unit is running but not cooling. Found outdoor pressures high and indoor pressures low. Condenser coils dirty and suction pressure low due to refrigerant leak. Performed leak searches and determined leak in air handler coils. Cleaned outdoor condenser coils. Added 1lb so system is temporarily cooling. Inspected blower wheel and assembly. Tested temp splits and starting components. 

Will call manufacture to verify warranty and parts availability 

Went over potential pricing for repair vs replacement
Upon arrival home owner states unit is running but not cooling. Found outdoor pressures high and indoor pressures low. Condenser coils dirty and suction pressure low due to refrigerant leak. Performed leak searches and determined leak in air handler coils. Cleaned outdoor condenser coils. Added 1lb so system is temporarily cooling. Inspected blower wheel and assembly. Tested temp splits and starting components. 

Will call manufacture to verify warranty and parts availability 

Went over potential pricing for repair vs replacement
Nathan A.
Nathan A. Checked in
Upon arrival home owner states unit is running but not cooling. Found outdoor pressures high and indoor pressures low. Condenser coils dirty and suction pressure low due to refrigerant leak. Performed leak searches and determined leak in air handler coils. Cleaned outdoor condenser coils. Added 1lb so system is temporarily cooling. Inspected blower wheel and assembly. Tested temp splits and starting components. Will call manufacture to verify warranty and parts availability Went over potential pricing for repair vs replacement
Largo, FL 33774
Michael A.
Michael A. Checked in
Upon my inspection, I found a clogged drain line and drain pan. In the attic, I noticed a massive hole in the 14” return duct work that needs to be replaced with new. I also found a dirty evaporator coil. System pressures were good, capacitor tested good, and amp draws on the compressor and fan motor were good. Cleaned and treated drain line/pan Scheduled for duct line replacement on August 18th 7:30am. Recommended to clean evaporator coils as they will get worse with the hole in the duct work. Client would like to wait on cleaning coils. System is cooling but not as efficient as it should be with only a 10° split.
Largo, FL 33771
Replace the return plenum and move the float switch to lower side of the pan
Replace the return plenum and move the float switch to lower side of the pan
Ricky O.
Ricky O. Checked in
Replace the return plenum and move the float switch to lower side of the pan
Largo, FL 33771
Michael A.
Michael A. Checked in
Upon arrival, found condenser fan motor not working. Tested capacitor and found bad capacitor. Replaced and recommended condenser coil cleaning. Cleaned condenser coil. Unit is running and cooling. Amp draw on compressor is good. Amp draw on condenser fan motor is slightly over factory recommended spec. Sending quote for new fan motor. System is cooling.
Largo, FL 33771
Michael A.
Michael A. Checked in
Upon my inspection, found bad thermostat communicating wire to condenser unit. Client opted to replace wire and system started up after completion. Evaporator coil is impacted with dirt and debris as well as the condenser coil. Client was advised that the coils should be cleaned soon and a quote is being sent. Will include drain line condensate pump clean with the quote complimentary. Pressures were off and possible causes are dirty coils as well as possibly the last installer did not properly vacuum and charge the system. Temp split is 10° If quote is accepted and scheduled, a proper recharge of the system with refrigerant will occur to fix any present issues. System is cooling
Largo, FL 33770
Bailey M.
Bailey M. Checked in
Patching return plenum to get unit through the night
Largo, FL 33771
Michael A.
Michael A. Checked in
Upon my inspection, I found the 5 ton system drain line, primary drain pan, and secondary pan were all full of sludge and water. Performed drain cleaning and treatment. System is back up and running and cooling properly with good temp split and good amp draws. Capacitor is good. I also looked at the 3 ton system and found that it is low on refrigerant and needs a leak inspection. Client was informed of possibly costs with finding and repairing a leak. Client requested a quote for a new system and will send over as soon as possible.
Largo, FL 33770
Upon arrival home owner states unit is running but not cooling. Found outdoor capacitor had failed. Replaced capacitor and verified operations. Cleaned condenser coils complimentary. Air handler coils impacted. Would recommend cleaning them in place. Blower wheel has moderate amount of buildup. Would recommend removing to sanitize. System is currently operating within manufacture specifications.
Upon arrival home owner states unit is running but not cooling. Found outdoor capacitor had failed. Replaced capacitor and verified operations. Cleaned condenser coils complimentary. Air handler coils impacted. Would recommend cleaning them in place. Blower wheel has moderate amount of buildup. Would recommend removing to sanitize. System is currently operating within manufacture specifications.
Nathan A.
Nathan A. Checked in
Upon arrival home owner states unit is running but not cooling. Found outdoor capacitor had failed. Replaced capacitor and verified operations. Cleaned condenser coils complimentary. Air handler coils impacted. Would recommend cleaning them in place. Blower wheel has moderate amount of buildup. Would recommend removing to sanitize. System is currently operating within manufacture specifications.
Largo, FL 33771
Home owner states he cleared condensate pump and unit will no longer turn on. Condensate pump safety switch shorted. Bypassed switch and explained the pump will need to be replaced because the floor can flood. He’s going to Home Depot today to replace. System is currently cooling (not to full potential).
Home owner states he cleared condensate pump and unit will no longer turn on. Condensate pump safety switch shorted. Bypassed switch and explained the pump will need to be replaced because the floor can flood. He’s going to Home Depot today to replace. System is currently cooling (not to full potential).
Nathan A.
Nathan A. Checked in
Home owner states he cleared condensate pump and unit will no longer turn on. Condensate pump safety switch shorted. Bypassed switch and explained the pump will need to be replaced because the floor can flood. He’s going to Home Depot today to replace. System is currently cooling (not to full potential).
Largo, FL 33770
Precision Tuneup

Checked refrigerant pressures. Tested capacitor- Capacitor is weak reading 37 out of 40 µF. Capacitor replacement is recommended to prevent damage to compressor. 
Checked contactor. Checked all wiring connections in condensing unit and cleaned out electrical cabinet. 
Removed outdoor fan to wash condensing coil. Washed out all leaves and debris inside condenser.
 Flushed vacuumed and treated condensate drain line. Tested float switch in emergency pan. System does not have a primary float switch. 
Checked air handler cleanliness. Blower wheel (fan inside attic unit) is dirty and has microbial growth on and around it. There is a UV element directly above the blower wheel, but it does not seem to be effective. Recommend blower cleaning and UV system replacement. 
Evaporator coil is clean and air handler wiring looks good. Checked air temperature. 
The system is running well at this time. sent estimates for capacitor replacement, blower cleaning and UV system replacement.
Precision Tuneup

Checked refrigerant pressures. Tested capacitor- Capacitor is weak reading 37 out of 40 µF. Capacitor replacement is recommended to prevent damage to compressor. 
Checked contactor. Checked all wiring connections in condensing unit and cleaned out electrical cabinet. 
Removed outdoor fan to wash condensing coil. Washed out all leaves and debris inside condenser.
 Flushed vacuumed and treated condensate drain line. Tested float switch in emergency pan. System does not have a primary float switch. 
Checked air handler cleanliness. Blower wheel (fan inside attic unit) is dirty and has microbial growth on and around it. There is a UV element directly above the blower wheel, but it does not seem to be effective. Recommend blower cleaning and UV system replacement. 
Evaporator coil is clean and air handler wiring looks good. Checked air temperature. 
The system is running well at this time. sent estimates for capacitor replacement, blower cleaning and UV system replacement.
Sha’nya B.
Sha’nya B. Checked in
Precision Tuneup Checked refrigerant pressures. Tested capacitor- Capacitor is weak reading 37 out of 40 µF. Capacitor replacement is recommended to prevent damage to compressor. Checked contactor. Checked all wiring connections in condensing unit and cleaned out electrical cabinet. Removed outdoor fan to wash condensing coil. Washed out all leaves and debris inside condenser. Flushed vacuumed and treated condensate drain line. Tested float switch in emergency pan. System does not have a primary float switch. Checked air handler cleanliness. Blower wheel (fan inside attic unit) is dirty and has microbial growth on and around it. There is a UV element directly above the blower wheel, but it does not seem to be effective. Recommend blower cleaning and UV system replacement. Evaporator coil is clean and air handler wiring looks good. Checked air temperature. The system is running well at this time. sent estimates for capacitor replacement, blower cleaning and UV system replacement.
Largo, FL 33770
Diagnosis. Waiting on financial applications to approve for system install.
Diagnosis. Waiting on financial applications to approve for system install.
Bailey M.
Bailey M. Checked in
Diagnosis. Waiting on financial applications to approve for system install.
Largo, FL 33770
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to bad blower motor. Replaced motor. Cleared pan and drain. Pressures good. Temp split good. Unit cooling at this time.
Largo, FL 33773
2.5T System 1400sf home 

Home owner states unit is not keeping up with temperature. Outside condenser has heavy corrosion due to gutter overflowing into unit. Inspected air handler and coils. Tested starting components. Checked temp splits and pressures. System is low on refrigerant indicating leak. Performed leak search. Checked air handler coils and all connections. Checked outdoor unit and connections. Found leak coming from corroded compressor. Condenser coils also starting to corrode. Explained potential future failures and repairs. Called manufacture to verify warranty and parts availability. 

Credit 50% of leak search towards repair. 175$ credit
2.5T System 1400sf home 

Home owner states unit is not keeping up with temperature. Outside condenser has heavy corrosion due to gutter overflowing into unit. Inspected air handler and coils. Tested starting components. Checked temp splits and pressures. System is low on refrigerant indicating leak. Performed leak search. Checked air handler coils and all connections. Checked outdoor unit and connections. Found leak coming from corroded compressor. Condenser coils also starting to corrode. Explained potential future failures and repairs. Called manufacture to verify warranty and parts availability. 

Credit 50% of leak search towards repair. 175$ credit
Nathan A.
Nathan A. Checked in
2.5T System 1400sf home Home owner states unit is not keeping up with temperature. Outside condenser has heavy corrosion due to gutter overflowing into unit. Inspected air handler and coils. Tested starting components. Checked temp splits and pressures. System is low on refrigerant indicating leak. Performed leak search. Checked air handler coils and all connections. Checked outdoor unit and connections. Found leak coming from corroded compressor. Condenser coils also starting to corrode. Explained potential future failures and repairs. Called manufacture to verify warranty and parts availability. Credit 50% of leak search towards repair. 175$ credit
Largo, FL 33774
Client states blower was not running. On arrival unit cooling properly. Air handler is full of growth and in poor condition. Blower and board might have possible intermittent issue causing blower to stop. Due to age and condition of unit we recommend to replace unit instead of making repairs. Unit is cooling at this time.
Client states blower was not running. On arrival unit cooling properly. Air handler is full of growth and in poor condition. Blower and board might have possible intermittent issue causing blower to stop. Due to age and condition of unit we recommend to replace unit instead of making repairs. Unit is cooling at this time.
Justin G.
Justin G. Checked in
Client states blower was not running. On arrival unit cooling properly. Air handler is full of growth and in poor condition. Blower and board might have possible intermittent issue causing blower to stop. Due to age and condition of unit we recommend to replace unit instead of making repairs. Unit is cooling at this time.
Largo, FL 33774
Justin G.
Justin G. Checked in
Install 2 warranty control boards. After replacing boards. Found voltage coming to unit was 254. Recommend to client not to turn on due to possible issues. Client understood possible problems and wanted to test. Unit ran for 15 min and cooling. Turned unit off to prevent further issues. Client must call duke to have them reduce voltage coming to house to prevent further board issues. Client is aware not to turn unit on until voltage is reduced.
Largo, FL 33770
Home owner states unit is still cooling and that they added refrigerant a month ago. Suspects leak is around compressor low side or around the shrader valves. Electronic and bubble leak search showing that condenser coils are leaking in non weldable joint. Will need to call manufacture to verify parts warranty and availability. 

*coil unavailable per Goodman manufacture
Home owner states unit is still cooling and that they added refrigerant a month ago. Suspects leak is around compressor low side or around the shrader valves. Electronic and bubble leak search showing that condenser coils are leaking in non weldable joint. Will need to call manufacture to verify parts warranty and availability. 

*coil unavailable per Goodman manufacture
Nathan A.
Nathan A. Checked in
Home owner states unit is still cooling and that they added refrigerant a month ago. Suspects leak is around compressor low side or around the shrader valves. Electronic and bubble leak search showing that condenser coils are leaking in non weldable joint. Will need to call manufacture to verify parts warranty and availability. *coil unavailable per Goodman manufacture
Largo, FL 33770

Contact the Bros You Know Today!

Schedule Service Online
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at 727-217-6148 .

By pressing Submit I agree to receive phone, email, or text messages from Air Bros Air Conditioning & Heating to the provided mobile number and also agree to the Air Bros Air Conditioning & Heating terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next