Expert Cooling, Heating and Electrical In Clearwater, FL

If you've lived in Clearwater for any length of time, you already know what August feels like when the AC goes out. It's not just uncomfortable — it's the kind of heat that makes an hour feel like a day. We started Air Bros because we grew up here, and we got tired of seeing neighbors get burned by out-of-town companies that didn't understand the difference between a Phoenix summer and a Gulf Coast one.

Clearwater's combination of salt air, nine months of cooling season, and humidity that rarely lets up puts real stress on HVAC equipment. We know this market, we know these homes, and we've seen firsthand what happens when the wrong company installs the wrong system for this climate. We're here to make sure that doesn't happen to you.

Professional AC Repair in Clearwater

When your AC stops working in Clearwater, waiting isn't an option. Temperatures and humidity make an uncomfortable home unbearable within hours, and in the middle of summer, same-day availability matters more than almost anything else.

Air Bros offers same-day Air Conditioning Repair throughout Clearwater and Clearwater Beach for all major brands and models. Our technicians diagnose and repair refrigerant leaks, failed capacitors, frozen evaporator coils, blower motor failures, faulty thermostats, and electrical faults. We arrive with a fully stocked truck so most repairs are completed in a single visit.

Homes near the Gulf are exposed to salt air that corrodes coil fins and electrical contacts faster than inland properties. We inspect for corrosion damage on every repair call and address it before it leads to a larger failure. All pricing is upfront and flat-rate before any work begins — no surprises when the job is done.

The Importance of Proper AC Installation

Choosing the right AC system for a Clearwater home requires more than picking a brand. It requires sizing the unit correctly for Florida's Climate Zone 2 and selecting equipment built to handle high humidity and extended run times. These are decisions that affect how comfortable your home feels and how much you spend on energy bills for the next decade.

An undersized system will run constantly without ever adequately dehumidifying your home. An oversized system will short-cycle, leaving excess moisture in the air and wearing out components prematurely. Either way, the wrong size costs you money every month and shortens the life of your equipment.

Air Bros installs Trane, Carrier, Lennox, and Daikin systems selected specifically for Gulf Coast performance. We recommend variable-speed compressors that manage humidity more effectively than single-stage units and run more quietly and efficiently over the long haul. Every AC System Replacement is permitted through Pinellas County and completed to Florida building code. We also walk you through available financing options and energy efficiency incentives before any contract is signed.

Why AC Maintenance in Clearwater is Paramount

In most of the country, annual AC maintenance is considered sufficient. In Clearwater, twice a year is the standard — and for good reason.

With a cooling season that runs from March through November, your system accumulates wear, dirt, and biological growth at a pace that a single annual visit can't keep up with. Neglected drain lines back up and cause water damage. Dirty coils make your system work harder and drive up your electric bill. Small issues that a technician would catch in April become expensive failures in July. Air Bros recommends a spring tune-up before peak cooling demand and a fall visit before humidity season winds down.

Each HVAC Maintenance visit includes coil cleaning, refrigerant level check, electrical inspection, condensate drain flush, and a corrosion assessment for properties near the water. For vacation rental owners and property managers on Clearwater Beach, we offer preventive maintenance contracts to reduce the risk of mid-booking breakdowns.

For homeowners who want year-round peace of mind, the Air Bros Premium Membership covers both visits for just $18 per month. Members pay no service call fees, get 10% off all repairs, have no overtime charges, and move to the front of the line with priority booking. In a market where a mid-August breakdown means competing with every other Clearwater home for a same-day technician, that priority access alone is worth it. If you're tired of reacting to problems and ready to get ahead of them, the membership is the most cost-effective way to keep your system running through whatever the Gulf Coast throws at it.

Why Clearwater Homeowners Choose Air Bros

We pull permits on every installation through Pinellas County, which protects your home's value and ensures your system is installed to code. Our pricing is upfront and flat-rate — you'll know the full cost before we start, with no surprise charges after the job is done.

Emergency service is available around the clock, including weekends and holidays, because AC failures don't wait for business hours. We service hundreds of beach properties annually and know exactly how to protect equipment from salt air corrosion and Florida humidity. When you call Air Bros, you're talking to someone who knows Clearwater — not a call center routing your ticket to whoever is available. If you have questions about our services, visit our HVAC FAQs page or contact us directly.

Clearwater's climate doesn't give your AC a break, and neither do we. Whether you're dealing with an unexpected breakdown, planning a new installation, or just staying ahead of the season, Air Bros is built for exactly this market. We've earned the trust of Clearwater homeowners by showing up on time, pricing honestly, and doing the job right the first time.

If you need AC Repair, AC Installation, or AC Maintenance, you can rely on Air Bros to take care of Clearwater. Call us today at 727-217-6148 to schedule your appointment.

How often should I service my AC in Clearwater, FL?

In Clearwater and throughout Florida, HVAC systems should be serviced twice per year — once in spring before the heavy cooling season, and once in fall. Florida's near-continuous cooling demand and high humidity place significantly more stress on AC systems than in northern states, making semi-annual maintenance essential rather than optional.

Why do AC systems near Clearwater Beach fail faster?

Properties within a few miles of the Gulf are exposed to salt air that accelerates corrosion on condenser coils, copper lines, and electrical contacts. This can reduce equipment lifespan by three to five years compared to inland Clearwater homes. Annual coil cleaning and corrosion-resistant coatings cost far less than early system replacement.

What HVAC brands work best in Clearwater's humid climate?

For Clearwater's high humidity and long cooling seasons, systems with strong dehumidification performance are the priority. Top performers include Trane, Carrier, Lennox, and Daikin — all offering units rated for Florida's Climate Zone 2. Variable-speed compressors are especially effective at controlling indoor humidity in Gulf Coast climates.

Do you service vacation rental properties in Clearwater Beach?

Yes. We work with many vacation rental owners and property managers throughout Clearwater Beach and the barrier islands. We prioritize fast turnaround on rental properties and offer preventive maintenance contracts to reduce mid-booking breakdowns.

Does humidity in Clearwater cause mold problems in AC systems?

Clearwater's year-round humidity creates ideal conditions for mold and biological growth inside air handlers, evaporator coils, and drain pans. Left unchecked, this circulates through your home's air and can cause health issues for residents. Air Bros inspects for mold and biological buildup on every maintenance visit and recommends UV light air purifiers for homes that have had recurring issues.

Is it worth replacing my AC system before hurricane season in Clearwater?

If your system is more than ten years old or has needed repeated repairs, replacing it before hurricane season is worth serious consideration. A storm doesn't just risk physical damage to your outdoor unit — the power surges and outages that follow can push an already-stressed system over the edge. Air Bros can assess your current system and give you an honest recommendation on whether repair or replacement makes more sense heading into June.

Recent Jobs and Reviews in Clearwater, FL

Clearwater, FL at a glance

Air Bros Air Conditioning & Electrical has completed 25 jobs in Clearwater, FL between August 2025 and September 2025.

The most recent job was on September 19, 2025.

Air Bros Air Conditioning & Electrical has completed 176 jobs in Clearwater, FL in the last 12 months. The first job there was in February 2025.

Job Locations and Reviews

Upon my inspection, found bad capacitor on system. Also found very dirty/impacted condenser coils. Recommended to deep chemical clean condenser coils. Evaporator coils are clean. Replaced capacitor and checked amp draw on fan motor and compressor. Compressor start up amps are 82.2 and the max rating in the data plate is 75. Compressor is over amping at at risk of failure on start up. Recommended to install a hard start kit to remedy the problem but no guarantee that it will fix the compressor permanently. Compressor running amp draw is 10.6 amps and max is 14.7. Condenser fan motor is pulling 1.5 amps and max rating is 1.7. 
Client would only like to change capacitor at this time. 
Sending quotes for other repairs/cleanings. 
System is cooling at this time with a 20° temperature split.
Upon my inspection, found bad capacitor on system. Also found very dirty/impacted condenser coils. Recommended to deep chemical clean condenser coils. Evaporator coils are clean. Replaced capacitor and checked amp draw on fan motor and compressor. Compressor start up amps are 82.2 and the max rating in the data plate is 75. Compressor is over amping at at risk of failure on start up. Recommended to install a hard start kit to remedy the problem but no guarantee that it will fix the compressor permanently. Compressor running amp draw is 10.6 amps and max is 14.7. Condenser fan motor is pulling 1.5 amps and max rating is 1.7. 
Client would only like to change capacitor at this time. 
Sending quotes for other repairs/cleanings. 
System is cooling at this time with a 20° temperature split.
Michael A.
Michael A. Checked in
Upon my inspection, found bad capacitor on system. Also found very dirty/impacted condenser coils. Recommended to deep chemical clean condenser coils. Evaporator coils are clean. Replaced capacitor and checked amp draw on fan motor and compressor. Compressor start up amps are 82.2 and the max rating in the data plate is 75. Compressor is over amping at at risk of failure on start up. Recommended to install a hard start kit to remedy the problem but no guarantee that it will fix the compressor permanently. Compressor running amp draw is 10.6 amps and max is 14.7. Condenser fan motor is pulling 1.5 amps and max rating is 1.7. Client would only like to change capacitor at this time. Sending quotes for other repairs/cleanings. System is cooling at this time with a 20° temperature split.
Clearwater, FL 33764
Pancake unit in ceiling with condenser on rooftop. Pan and drain backing up causing system to shut off. Drain line shares upstairs unit. Cleared drain line and pan. Verified system operations. 

Drain pan not pitched properly. Potential issue in future.
Pancake unit in ceiling with condenser on rooftop. Pan and drain backing up causing system to shut off. Drain line shares upstairs unit. Cleared drain line and pan. Verified system operations. 

Drain pan not pitched properly. Potential issue in future.
Nathan A.
Nathan A. Checked in
Pancake unit in ceiling with condenser on rooftop. Pan and drain backing up causing system to shut off. Drain line shares upstairs unit. Cleared drain line and pan. Verified system operations. Drain pan not pitched properly. Potential issue in future.
Clearwater, FL 33764
Replace the burnt up splice in the meter enclosure
Replace the burnt up splice in the meter enclosure
Griffin K.
Griffin K. Checked in
Replace the burnt up splice in the meter enclosure
Clearwater, FL 33761
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Added chemical to help prevent growth. Unit cooling at this time.
Clearwater, FL 33755
On arrival found home not getting 240v to home panel. Found bad main breaker at meter box. Will return to replace breaker.
On arrival found home not getting 240v to home panel. Found bad main breaker at meter box. Will return to replace breaker.
Justin G.
Justin G. Checked in
On arrival found home not getting 240v to home panel. Found bad main breaker at meter box. Will return to replace breaker.
Clearwater, FL 33761
On arrival found u it not cooling due to burnt disconnect and weak capacitor. Replaced parts and tested. Found unit to be low on refrigerant. Added 2 lbs to bring unit back to factory specs. Performed maintenance on system. Unit cooling properly at this time.
On arrival found u it not cooling due to burnt disconnect and weak capacitor. Replaced parts and tested. Found unit to be low on refrigerant. Added 2 lbs to bring unit back to factory specs. Performed maintenance on system. Unit cooling properly at this time.
Justin G.
Justin G. Checked in
On arrival found u it not cooling due to burnt disconnect and weak capacitor. Replaced parts and tested. Found unit to be low on refrigerant. Added 2 lbs to bring unit back to factory specs. Performed maintenance on system. Unit cooling properly at this time.
Clearwater, FL 33762
Installed safety float switch. Installed new drain line with p trap to condensate pump. Installed insulation on drain line. Installed new breaker on unit. Removed existing broken air purifier. Sending quote for new air purifier and UV bulb system.
Installed safety float switch. Installed new drain line with p trap to condensate pump. Installed insulation on drain line. Installed new breaker on unit. Removed existing broken air purifier. Sending quote for new air purifier and UV bulb system.
Michael A.
Michael A. Checked in
Installed safety float switch. Installed new drain line with p trap to condensate pump. Installed insulation on drain line. Installed new breaker on unit. Removed existing broken air purifier. Sending quote for new air purifier and UV bulb system.
Clearwater, FL 33765
Upon my inspection, found system was low on refrigerant and tripping on low pressure. Added 16lbs of refrigerant and the compressor started going out on thermal overload. Upon further diagnosis, I found the second stage solenoid has an OL. Compressor is not pumping refrigerant properly in single stage and only guarantee is replacement of warranty compressor with all new refrigerant, new filter line dryer, and acid avenger. 
Client would like to leave system off. Sending quote for warranty replacement.
Upon my inspection, found system was low on refrigerant and tripping on low pressure. Added 16lbs of refrigerant and the compressor started going out on thermal overload. Upon further diagnosis, I found the second stage solenoid has an OL. Compressor is not pumping refrigerant properly in single stage and only guarantee is replacement of warranty compressor with all new refrigerant, new filter line dryer, and acid avenger. 
Client would like to leave system off. Sending quote for warranty replacement.
Michael A.
Michael A. Checked in
Upon my inspection, found system was low on refrigerant and tripping on low pressure. Added 16lbs of refrigerant and the compressor started going out on thermal overload. Upon further diagnosis, I found the second stage solenoid has an OL. Compressor is not pumping refrigerant properly in single stage and only guarantee is replacement of warranty compressor with all new refrigerant, new filter line dryer, and acid avenger. Client would like to leave system off. Sending quote for warranty replacement.
Clearwater, FL 33762
Found unit low on gas. Client wants to wait to review options right now .
Found unit low on gas. Client wants to wait to review options right now .
Ricky O.
Ricky O. Checked in
Found unit low on gas. Client wants to wait to review options right now .
Clearwater, FL 33761
Upon my inspection, I found the UV system wire was destroyed from rubbing up against the bare metal hole that was cut into the air handler. Performed a small repair on issue to prevent a fire hazard. Upon further inspection, I found a weak capacitor, compressor over amping on start up, no safety switch, no p trap, no insulation on drain line, dirty primary drain pan, dirty condensate pump, and a corroded 60amp breaker at the air handler. Clients would like to make all necessary repairs. Changed capacitor, installed hard start kit, and make necessary repairs to the burnt wire at this time. Returning to perform the rest of the repairs at a later date. System is now cooling with a 17° temperature split. 

Sending a quote for a new air purifier installed correctly if client would like to replace their air purifier.
Upon my inspection, I found the UV system wire was destroyed from rubbing up against the bare metal hole that was cut into the air handler. Performed a small repair on issue to prevent a fire hazard. Upon further inspection, I found a weak capacitor, compressor over amping on start up, no safety switch, no p trap, no insulation on drain line, dirty primary drain pan, dirty condensate pump, and a corroded 60amp breaker at the air handler. Clients would like to make all necessary repairs. Changed capacitor, installed hard start kit, and make necessary repairs to the burnt wire at this time. Returning to perform the rest of the repairs at a later date. System is now cooling with a 17° temperature split. 

Sending a quote for a new air purifier installed correctly if client would like to replace their air purifier.
Michael A.
Michael A. Checked in
Upon my inspection, I found the UV system wire was destroyed from rubbing up against the bare metal hole that was cut into the air handler. Performed a small repair on issue to prevent a fire hazard. Upon further inspection, I found a weak capacitor, compressor over amping on start up, no safety switch, no p trap, no insulation on drain line, dirty primary drain pan, dirty condensate pump, and a corroded 60amp breaker at the air handler. Clients would like to make all necessary repairs. Changed capacitor, installed hard start kit, and make necessary repairs to the burnt wire at this time. Returning to perform the rest of the repairs at a later date. System is now cooling with a 17° temperature split. Sending a quote for a new air purifier installed correctly if client would like to replace their air purifier.
Clearwater, FL 33765
Home owner states units do not keep up during warmer parts of the day. Issue has been happening since install. Home is 2750sf with a 3.5T and 2T system. Home also has single pain windows. Explained that we would need to size up one of the system to compensate for heat load.

3.5T Recommendations 
-Supply plenum sweating (not sealed properly). Need to replace partial of supply plenum and seal properly
-Bacterial growth accumulating inside air handler and blower wheel. (Remove & Sanitize Blower Wheel Assembly). Will sanitize interior cabinet once blower is removed. 
-Pitch air handler forward as primary drain pan is holding water 
-Install Air Purifier 

2T Recommendations 
-New Supply Plenum (Currently sweating and undersized)
-Clean Blower wheel in place 
-Install Air Purifier 

Explained that me doing this scope of work will not solve cooling issue. Home owner also interested in duct sanitation & soft start kits. 

Sent over estimates for remediation and repairs. Sent over for members
Home owner states units do not keep up during warmer parts of the day. Issue has been happening since install. Home is 2750sf with a 3.5T and 2T system. Home also has single pain windows. Explained that we would need to size up one of the system to compensate for heat load.

3.5T Recommendations 
-Supply plenum sweating (not sealed properly). Need to replace partial of supply plenum and seal properly
-Bacterial growth accumulating inside air handler and blower wheel. (Remove & Sanitize Blower Wheel Assembly). Will sanitize interior cabinet once blower is removed. 
-Pitch air handler forward as primary drain pan is holding water 
-Install Air Purifier 

2T Recommendations 
-New Supply Plenum (Currently sweating and undersized)
-Clean Blower wheel in place 
-Install Air Purifier 

Explained that me doing this scope of work will not solve cooling issue. Home owner also interested in duct sanitation & soft start kits. 

Sent over estimates for remediation and repairs. Sent over for members
Nathan A.
Nathan A. Checked in
Home owner states units do not keep up during warmer parts of the day. Issue has been happening since install. Home is 2750sf with a 3.5T and 2T system. Home also has single pain windows. Explained that we would need to size up one of the system to compensate for heat load. 3.5T Recommendations -Supply plenum sweating (not sealed properly). Need to replace partial of supply plenum and seal properly -Bacterial growth accumulating inside air handler and blower wheel. (Remove & Sanitize Blower Wheel Assembly). Will sanitize interior cabinet once blower is removed. -Pitch air handler forward as primary drain pan is holding water -Install Air Purifier 2T Recommendations -New Supply Plenum (Currently sweating and undersized) -Clean Blower wheel in place -Install Air Purifier Explained that me doing this scope of work will not solve cooling issue. Home owner also interested in duct sanitation & soft start kits. Sent over estimates for remediation and repairs. Sent over for members
Clearwater, FL 33761
Justin G.
Justin G. Checked in
On arrival found downstairs unit not cooling due to clogged drain. Cleared pan and drain. Added chemical to help prevent growth. Unit has 21* temp split. Unit is cooling and drawing properly at this time.
Clearwater, FL 33767
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to weak capacitor. Replaced part. Start and test. Rinsed and cleaned coil to help unit be more efficient. Unit cooling properly at this time.
Clearwater, FL 33760
Justin G.
Justin G. Checked in
Performed maintenance on 5 systems. Changed all filters. All systems are draining and cooling properly.
Clearwater, FL 33762
Justin G.
Justin G. Checked in
On arrival found breaker for condenser getting hot causing it to trip. Replaced breaker and tightened all connections. Breaker staying cool. Unit cooling. Heard arching in panel when putting cover back on. Electrician will return tomorrow to look over panel.
Clearwater, FL 33764
RUUD Equipment (2 Stage)
Install New Air Handler 
Install Air Handler UV System
Install New Outdoor Condenser 
New Filter Drier 
Install Thermostat (Ecobee)
Thermostat Wire Included 
Primary Float Safety Switch
Secondary Float Safety Switch 
Install Horizontal Drain Pan
Outdoor Surge Protection 
UV Rated Outdoor Insulation 
Refrigerant Locking Caps
Flush Existing Refrigerant Lines
Flush Drain Line
4” Hurricane Pad
Vibration Pads
Hurricane Tie Down Straps
Vacuum System 
Seal Supply/Return Plenums 
Remove Current Equipment
Permitting 
10 Year Parts Warranty
3 Year Labor Warranty 
100% Satisfaction 

*Cap and remove supply duct on back side air handler plenum
*Complimentary portable ac unit
RUUD Equipment (2 Stage)
Install New Air Handler 
Install Air Handler UV System
Install New Outdoor Condenser 
New Filter Drier 
Install Thermostat (Ecobee)
Thermostat Wire Included 
Primary Float Safety Switch
Secondary Float Safety Switch 
Install Horizontal Drain Pan
Outdoor Surge Protection 
UV Rated Outdoor Insulation 
Refrigerant Locking Caps
Flush Existing Refrigerant Lines
Flush Drain Line
4” Hurricane Pad
Vibration Pads
Hurricane Tie Down Straps
Vacuum System 
Seal Supply/Return Plenums 
Remove Current Equipment
Permitting 
10 Year Parts Warranty
3 Year Labor Warranty 
100% Satisfaction 

*Cap and remove supply duct on back side air handler plenum
*Complimentary portable ac unit
Kyle K.
Kyle K. Checked in
RUUD Equipment (2 Stage) Install New Air Handler Install Air Handler UV System Install New Outdoor Condenser New Filter Drier Install Thermostat (Ecobee) Thermostat Wire Included Primary Float Safety Switch Secondary Float Safety Switch Install Horizontal Drain Pan Outdoor Surge Protection UV Rated Outdoor Insulation Refrigerant Locking Caps Flush Existing Refrigerant Lines Flush Drain Line 4” Hurricane Pad Vibration Pads Hurricane Tie Down Straps Vacuum System Seal Supply/Return Plenums Remove Current Equipment Permitting 10 Year Parts Warranty 3 Year Labor Warranty 100% Satisfaction *Cap and remove supply duct on back side air handler plenum *Complimentary portable ac unit
Clearwater, FL 33760
Upon my inspection, I found a thermostat wire going from the thermostat to the air handler was completely disconnected in the attic. A new thermostat wire must be installed from thermostat to air handler due to the broken thermostat wire in the wall being unattainable/stuck in the wall with no access. Pulled new thermostat wire through attic and made proper new connections. Common wire was not originally connected, so I made a common wire connection. System is now cooling. 

Notes: noticed a pool of water next to air handler. Client would like to contact company who installed the system to figure out why their pvc connections are possibly leaking or if the unit is leaking water from the drain pan.
Upon my inspection, I found a thermostat wire going from the thermostat to the air handler was completely disconnected in the attic. A new thermostat wire must be installed from thermostat to air handler due to the broken thermostat wire in the wall being unattainable/stuck in the wall with no access. Pulled new thermostat wire through attic and made proper new connections. Common wire was not originally connected, so I made a common wire connection. System is now cooling. 

Notes: noticed a pool of water next to air handler. Client would like to contact company who installed the system to figure out why their pvc connections are possibly leaking or if the unit is leaking water from the drain pan.
Michael A.
Michael A. Checked in
Upon my inspection, I found a thermostat wire going from the thermostat to the air handler was completely disconnected in the attic. A new thermostat wire must be installed from thermostat to air handler due to the broken thermostat wire in the wall being unattainable/stuck in the wall with no access. Pulled new thermostat wire through attic and made proper new connections. Common wire was not originally connected, so I made a common wire connection. System is now cooling. Notes: noticed a pool of water next to air handler. Client would like to contact company who installed the system to figure out why their pvc connections are possibly leaking or if the unit is leaking water from the drain pan.
Clearwater, FL 33761
Upon my inspection, I found a severely clogged primary drain pan and drain line. This was causing the air handler to flood and leak into the ceiling. The safety switch was also pitched up and not allowing for the system to cut off. 
I performed a drain cleaning and treatment to the system. System will need time to dry up all the moisture. 
Performed Maitenence on system. 
Amp draws are good
Pressures are great
Capacitors tested within factory specs
System is cooling with a 20° temp split.
Upon my inspection, I found a severely clogged primary drain pan and drain line. This was causing the air handler to flood and leak into the ceiling. The safety switch was also pitched up and not allowing for the system to cut off. 
I performed a drain cleaning and treatment to the system. System will need time to dry up all the moisture. 
Performed Maitenence on system. 
Amp draws are good
Pressures are great
Capacitors tested within factory specs
System is cooling with a 20° temp split.
Michael A.
Michael A. Checked in
Upon my inspection, I found a severely clogged primary drain pan and drain line. This was causing the air handler to flood and leak into the ceiling. The safety switch was also pitched up and not allowing for the system to cut off. I performed a drain cleaning and treatment to the system. System will need time to dry up all the moisture. Performed Maitenence on system. Amp draws are good Pressures are great Capacitors tested within factory specs System is cooling with a 20° temp split.
Clearwater, FL 33764
Justin G.
Justin G. Checked in
Found cut thermostat wire in attic from air handler to thermostat causing unit not to run. Will return tomorrow to pull new wire.
Clearwater, FL 33761
Upon arrival found air handler overflowing due to failed safety switch and clogged drain line/pan. Nitrogen purged drain line and cleared drain pan. Added pan tabs to help with buildup. Verified pan or fittings were not cracked/loose. Replaced float safety switch. Verified system operations. Air handler coils impacted with dirt/debris. Air handler cabinet starting to severely rust due to multiple over flows. Checked temperature splits after completing work. 

Home owner verified scope of work via phone call.
Upon arrival found air handler overflowing due to failed safety switch and clogged drain line/pan. Nitrogen purged drain line and cleared drain pan. Added pan tabs to help with buildup. Verified pan or fittings were not cracked/loose. Replaced float safety switch. Verified system operations. Air handler coils impacted with dirt/debris. Air handler cabinet starting to severely rust due to multiple over flows. Checked temperature splits after completing work. 

Home owner verified scope of work via phone call.
Nathan A.
Nathan A. Checked in
Upon arrival found air handler overflowing due to failed safety switch and clogged drain line/pan. Nitrogen purged drain line and cleared drain pan. Added pan tabs to help with buildup. Verified pan or fittings were not cracked/loose. Replaced float safety switch. Verified system operations. Air handler coils impacted with dirt/debris. Air handler cabinet starting to severely rust due to multiple over flows. Checked temperature splits after completing work. Home owner verified scope of work via phone call.
Clearwater, FL 33762
I’m. Arrival found unit not cooling due to bad contactor on condenser and weak capacitor. Replaced parts start and test. Pressures good. Temp split good. Unit is very corroded. Made client aware. Unit cooling properly at this time.
I’m. Arrival found unit not cooling due to bad contactor on condenser and weak capacitor. Replaced parts start and test. Pressures good. Temp split good. Unit is very corroded. Made client aware. Unit cooling properly at this time.
Justin G.
Justin G. Checked in
I’m. Arrival found unit not cooling due to bad contactor on condenser and weak capacitor. Replaced parts start and test. Pressures good. Temp split good. Unit is very corroded. Made client aware. Unit cooling properly at this time.
Clearwater, FL 33767
Upon my inspection, I found a bad capacitor, dirty condenser coils, and an improper refrigerant charge. Replaced capacitor, performed a deep chemical clean on condenser coils, and added a pound of refrigerant. System is now cooling with a 20° temperature split. Client joined our membership plan and I performed a drain cleaning and treatment along with the other work today.
Upon my inspection, I found a bad capacitor, dirty condenser coils, and an improper refrigerant charge. Replaced capacitor, performed a deep chemical clean on condenser coils, and added a pound of refrigerant. System is now cooling with a 20° temperature split. Client joined our membership plan and I performed a drain cleaning and treatment along with the other work today.
Michael A.
Michael A. Checked in
Upon my inspection, I found a bad capacitor, dirty condenser coils, and an improper refrigerant charge. Replaced capacitor, performed a deep chemical clean on condenser coils, and added a pound of refrigerant. System is now cooling with a 20° temperature split. Client joined our membership plan and I performed a drain cleaning and treatment along with the other work today.
Clearwater, FL 33756
Installed UV system and cleaned out all growth.
Installed UV system and cleaned out all growth.
Michael A.
Michael A. Checked in
Installed UV system and cleaned out all growth.
Clearwater, FL 33760
Home owner states unit not cooling or turning on. Found drain line heavily backed up causing safety to turn off system. Found capacitor reading weak. Replaced capacitor and cleared drain line. 

Home owner signed up for maintenance plan. Performed maintenance same day. 

Full system tuneup 

Wiped Down Air Handler 

Checked contactor 

Inspected wiring 

Compressor amps 

Motor amps 

Cleaned condenser coils 

Checked refrigerant pressures 

Checked blower amps 

Checked filter (replaced) 

Thermostat operations 

Checked heating and cooling 

Unit is operating at this time 

*Home owner would like to add mini split to addition closet are. Also states they had some ducting replaced and still have a warm room. Recommend placing mini split centered of closet to cool room and closet. Flat roof so not able to add ducting
Home owner states unit not cooling or turning on. Found drain line heavily backed up causing safety to turn off system. Found capacitor reading weak. Replaced capacitor and cleared drain line. 

Home owner signed up for maintenance plan. Performed maintenance same day. 

Full system tuneup 

Wiped Down Air Handler 

Checked contactor 

Inspected wiring 

Compressor amps 

Motor amps 

Cleaned condenser coils 

Checked refrigerant pressures 

Checked blower amps 

Checked filter (replaced) 

Thermostat operations 

Checked heating and cooling 

Unit is operating at this time 

*Home owner would like to add mini split to addition closet are. Also states they had some ducting replaced and still have a warm room. Recommend placing mini split centered of closet to cool room and closet. Flat roof so not able to add ducting
Nathan A.
Nathan A. Checked in
Home owner states unit not cooling or turning on. Found drain line heavily backed up causing safety to turn off system. Found capacitor reading weak. Replaced capacitor and cleared drain line. Home owner signed up for maintenance plan. Performed maintenance same day. Full system tuneup Wiped Down Air Handler Checked contactor Inspected wiring Compressor amps Motor amps Cleaned condenser coils Checked refrigerant pressures Checked blower amps Checked filter (replaced) Thermostat operations Checked heating and cooling Unit is operating at this time *Home owner would like to add mini split to addition closet are. Also states they had some ducting replaced and still have a warm room. Recommend placing mini split centered of closet to cool room and closet. Flat roof so not able to add ducting
Clearwater, FL 33755
Michael A.
Michael A. Checked in
System is in great working condition. Temp split is 20° System pressures are great Capacitor is within factory specs Contactar is in good condition Amp draws on the motors and compressor are good Cleaned and treated drain line/ drain pan Rinsed condenser coils Recommendations: - UV light system for inside air handler to combat growth. (Clean the growth first) - Maitenence plan to keep the system looking and running this good for as long as possible.
Clearwater, FL 33760