Expert Cooling, Heating and Electrical In Clearwater, FL

If you've lived in Clearwater for any length of time, you already know what August feels like when the AC goes out. It's not just uncomfortable — it's the kind of heat that makes an hour feel like a day. We started Air Bros because we grew up here, and we got tired of seeing neighbors get burned by out-of-town companies that didn't understand the difference between a Phoenix summer and a Gulf Coast one.

Clearwater's combination of salt air, nine months of cooling season, and humidity that rarely lets up puts real stress on HVAC equipment. We know this market, we know these homes, and we've seen firsthand what happens when the wrong company installs the wrong system for this climate. We're here to make sure that doesn't happen to you.

Professional AC Repair in Clearwater

When your AC stops working in Clearwater, waiting isn't an option. Temperatures and humidity make an uncomfortable home unbearable within hours, and in the middle of summer, same-day availability matters more than almost anything else.

Air Bros offers same-day Air Conditioning Repair throughout Clearwater and Clearwater Beach for all major brands and models. Our technicians diagnose and repair refrigerant leaks, failed capacitors, frozen evaporator coils, blower motor failures, faulty thermostats, and electrical faults. We arrive with a fully stocked truck so most repairs are completed in a single visit.

Homes near the Gulf are exposed to salt air that corrodes coil fins and electrical contacts faster than inland properties. We inspect for corrosion damage on every repair call and address it before it leads to a larger failure. All pricing is upfront and flat-rate before any work begins — no surprises when the job is done.

The Importance of Proper AC Installation

Choosing the right AC system for a Clearwater home requires more than picking a brand. It requires sizing the unit correctly for Florida's Climate Zone 2 and selecting equipment built to handle high humidity and extended run times. These are decisions that affect how comfortable your home feels and how much you spend on energy bills for the next decade.

An undersized system will run constantly without ever adequately dehumidifying your home. An oversized system will short-cycle, leaving excess moisture in the air and wearing out components prematurely. Either way, the wrong size costs you money every month and shortens the life of your equipment.

Air Bros installs Trane, Carrier, Lennox, and Daikin systems selected specifically for Gulf Coast performance. We recommend variable-speed compressors that manage humidity more effectively than single-stage units and run more quietly and efficiently over the long haul. Every AC System Replacement is permitted through Pinellas County and completed to Florida building code. We also walk you through available financing options and energy efficiency incentives before any contract is signed.

Why AC Maintenance in Clearwater is Paramount

In most of the country, annual AC maintenance is considered sufficient. In Clearwater, twice a year is the standard — and for good reason.

With a cooling season that runs from March through November, your system accumulates wear, dirt, and biological growth at a pace that a single annual visit can't keep up with. Neglected drain lines back up and cause water damage. Dirty coils make your system work harder and drive up your electric bill. Small issues that a technician would catch in April become expensive failures in July. Air Bros recommends a spring tune-up before peak cooling demand and a fall visit before humidity season winds down.

Each HVAC Maintenance visit includes coil cleaning, refrigerant level check, electrical inspection, condensate drain flush, and a corrosion assessment for properties near the water. For vacation rental owners and property managers on Clearwater Beach, we offer preventive maintenance contracts to reduce the risk of mid-booking breakdowns.

For homeowners who want year-round peace of mind, the Air Bros Premium Membership covers both visits for just $18 per month. Members pay no service call fees, get 10% off all repairs, have no overtime charges, and move to the front of the line with priority booking. In a market where a mid-August breakdown means competing with every other Clearwater home for a same-day technician, that priority access alone is worth it. If you're tired of reacting to problems and ready to get ahead of them, the membership is the most cost-effective way to keep your system running through whatever the Gulf Coast throws at it.

Why Clearwater Homeowners Choose Air Bros

We pull permits on every installation through Pinellas County, which protects your home's value and ensures your system is installed to code. Our pricing is upfront and flat-rate — you'll know the full cost before we start, with no surprise charges after the job is done.

Emergency service is available around the clock, including weekends and holidays, because AC failures don't wait for business hours. We service hundreds of beach properties annually and know exactly how to protect equipment from salt air corrosion and Florida humidity. When you call Air Bros, you're talking to someone who knows Clearwater — not a call center routing your ticket to whoever is available. If you have questions about our services, visit our HVAC FAQs page or contact us directly.

Clearwater's climate doesn't give your AC a break, and neither do we. Whether you're dealing with an unexpected breakdown, planning a new installation, or just staying ahead of the season, Air Bros is built for exactly this market. We've earned the trust of Clearwater homeowners by showing up on time, pricing honestly, and doing the job right the first time.

If you need AC Repair, AC Installation, or AC Maintenance, you can rely on Air Bros to take care of Clearwater. Call us today at 727-217-6148 to schedule your appointment.

How often should I service my AC in Clearwater, FL?

In Clearwater and throughout Florida, HVAC systems should be serviced twice per year — once in spring before the heavy cooling season, and once in fall. Florida's near-continuous cooling demand and high humidity place significantly more stress on AC systems than in northern states, making semi-annual maintenance essential rather than optional.

Why do AC systems near Clearwater Beach fail faster?

Properties within a few miles of the Gulf are exposed to salt air that accelerates corrosion on condenser coils, copper lines, and electrical contacts. This can reduce equipment lifespan by three to five years compared to inland Clearwater homes. Annual coil cleaning and corrosion-resistant coatings cost far less than early system replacement.

What HVAC brands work best in Clearwater's humid climate?

For Clearwater's high humidity and long cooling seasons, systems with strong dehumidification performance are the priority. Top performers include Trane, Carrier, Lennox, and Daikin — all offering units rated for Florida's Climate Zone 2. Variable-speed compressors are especially effective at controlling indoor humidity in Gulf Coast climates.

Do you service vacation rental properties in Clearwater Beach?

Yes. We work with many vacation rental owners and property managers throughout Clearwater Beach and the barrier islands. We prioritize fast turnaround on rental properties and offer preventive maintenance contracts to reduce mid-booking breakdowns.

Does humidity in Clearwater cause mold problems in AC systems?

Clearwater's year-round humidity creates ideal conditions for mold and biological growth inside air handlers, evaporator coils, and drain pans. Left unchecked, this circulates through your home's air and can cause health issues for residents. Air Bros inspects for mold and biological buildup on every maintenance visit and recommends UV light air purifiers for homes that have had recurring issues.

Is it worth replacing my AC system before hurricane season in Clearwater?

If your system is more than ten years old or has needed repeated repairs, replacing it before hurricane season is worth serious consideration. A storm doesn't just risk physical damage to your outdoor unit — the power surges and outages that follow can push an already-stressed system over the edge. Air Bros can assess your current system and give you an honest recommendation on whether repair or replacement makes more sense heading into June.

Recent Jobs and Reviews in Clearwater, FL

Clearwater, FL at a glance

Air Bros Air Conditioning & Electrical has completed 25 jobs in Clearwater, FL between July 2025 and August 2025.

The most recent job was on August 11, 2025.

Air Bros Air Conditioning & Electrical has completed 176 jobs in Clearwater, FL in the last 12 months. The first job there was in February 2025.

Job Locations and Reviews

Upon arrival home owner states unit is leaking water. Did a full check up on system. Found drain line clogged into pan and outdoor capacitor reading weak. Home owner states capacitor was just replaced but does not trust the company. Home owner had condensers about bacteria in ductwork. Explained we offer duct sanitation. Home owner signed up for maintenance plan so discounted services.

Scope of work 
-replace outdoor capacitor 
-cleared drain line and pan (added pan tabs to help with buildup)
-duct sanitation

Performed rest of system tuneup. 

-motor amps 
-compressor amps 
-blower amps 
-tested new capacitor 
-inspected high/low voltage wiring 
-cleaned outdoor coils 
-tested temp splits and pressures 
-inspected blower wheel for growth and bacteria 
-inspected indoor coils 
-thermostat operations 
-checked filter 

System is operating at this time 

*another company told her she needs a new system. System is operating within manufacture specifications and no signs of mold/bacteria
Upon arrival home owner states unit is leaking water. Did a full check up on system. Found drain line clogged into pan and outdoor capacitor reading weak. Home owner states capacitor was just replaced but does not trust the company. Home owner had condensers about bacteria in ductwork. Explained we offer duct sanitation. Home owner signed up for maintenance plan so discounted services.

Scope of work 
-replace outdoor capacitor 
-cleared drain line and pan (added pan tabs to help with buildup)
-duct sanitation

Performed rest of system tuneup. 

-motor amps 
-compressor amps 
-blower amps 
-tested new capacitor 
-inspected high/low voltage wiring 
-cleaned outdoor coils 
-tested temp splits and pressures 
-inspected blower wheel for growth and bacteria 
-inspected indoor coils 
-thermostat operations 
-checked filter 

System is operating at this time 

*another company told her she needs a new system. System is operating within manufacture specifications and no signs of mold/bacteria
Nathan A.
Nathan A. Checked in
Upon arrival home owner states unit is leaking water. Did a full check up on system. Found drain line clogged into pan and outdoor capacitor reading weak. Home owner states capacitor was just replaced but does not trust the company. Home owner had condensers about bacteria in ductwork. Explained we offer duct sanitation. Home owner signed up for maintenance plan so discounted services. Scope of work -replace outdoor capacitor -cleared drain line and pan (added pan tabs to help with buildup) -duct sanitation Performed rest of system tuneup. -motor amps -compressor amps -blower amps -tested new capacitor -inspected high/low voltage wiring -cleaned outdoor coils -tested temp splits and pressures -inspected blower wheel for growth and bacteria -inspected indoor coils -thermostat operations -checked filter System is operating at this time *another company told her she needs a new system. System is operating within manufacture specifications and no signs of mold/bacteria
Clearwater, FL 33763
Michael A.
Michael A. Checked in
Found bad compressor. Recommended system replacement. Will send quote to client for new system install.
Clearwater, FL 33762
On arrival found unit not cooling properly due to low refrigerant levels in unit. Performed leak search and found condenser coil leaking. Will submit estimate for coil replacement. Added 1 lb of refrigerant to help get client by til coil is replaced. Made client aware that warranty expires on system on 8/21/25 and coil must be replaced by them to process warranty. Unit cooling at this time.
On arrival found unit not cooling properly due to low refrigerant levels in unit. Performed leak search and found condenser coil leaking. Will submit estimate for coil replacement. Added 1 lb of refrigerant to help get client by til coil is replaced. Made client aware that warranty expires on system on 8/21/25 and coil must be replaced by them to process warranty. Unit cooling at this time.
Justin G.
Justin G. Checked in
On arrival found unit not cooling properly due to low refrigerant levels in unit. Performed leak search and found condenser coil leaking. Will submit estimate for coil replacement. Added 1 lb of refrigerant to help get client by til coil is replaced. Made client aware that warranty expires on system on 8/21/25 and coil must be replaced by them to process warranty. Unit cooling at this time.
Clearwater, FL 33763
Kyle K.
Kyle K. Checked in
Perform pull and clean on blower motor and evap coil. Replace bad txv. Pull vacuum and test for leaks. Start and test. Tax and labor included.
Clearwater, FL 33761
Client states unit does not keep up throughout day. Found unit with dirty filter. Adjusted fan speed to get better split. Advised client that once tree was cut down that the home is struggling with heat load. Unit cooling to the best of its ability at this time.
Client states unit does not keep up throughout day. Found unit with dirty filter. Adjusted fan speed to get better split. Advised client that once tree was cut down that the home is struggling with heat load. Unit cooling to the best of its ability at this time.
Justin G.
Justin G. Checked in
Client states unit does not keep up throughout day. Found unit with dirty filter. Adjusted fan speed to get better split. Advised client that once tree was cut down that the home is struggling with heat load. Unit cooling to the best of its ability at this time.
Clearwater, FL 33764
On arrival found unit not cooling properly due to clogged condenser coil. Performed chemical cleaning on coil. Pressures good. Temp split good. Unit cooling properly at his time.
On arrival found unit not cooling properly due to clogged condenser coil. Performed chemical cleaning on coil. Pressures good. Temp split good. Unit cooling properly at his time.
Justin G.
Justin G. Checked in
On arrival found unit not cooling properly due to clogged condenser coil. Performed chemical cleaning on coil. Pressures good. Temp split good. Unit cooling properly at his time.
Clearwater, FL 33764
On arrival found unit not cooling properly due to restricted txv. Unit has 16* split. Found both evap coil and condenser coil extremely impacted causing lack of air flow and reduced cooling capacity. Performed drain and condenser coil cleaning. Will submit estimate for  evap and blower cleaning with new txv. Unit is cooling to the best of its ability.
On arrival found unit not cooling properly due to restricted txv. Unit has 16* split. Found both evap coil and condenser coil extremely impacted causing lack of air flow and reduced cooling capacity. Performed drain and condenser coil cleaning. Will submit estimate for  evap and blower cleaning with new txv. Unit is cooling to the best of its ability.
Justin G.
Justin G. Checked in
On arrival found unit not cooling properly due to restricted txv. Unit has 16* split. Found both evap coil and condenser coil extremely impacted causing lack of air flow and reduced cooling capacity. Performed drain and condenser coil cleaning. Will submit estimate for evap and blower cleaning with new txv. Unit is cooling to the best of its ability.
Clearwater, FL 33761
Upon arrival home owner states unit is running but not cooling. Checked float safety switch. Inspected indoor and outdoor coils. Inspected inside air handler cabinet. Interior cabinet is starting to accumulate bacterial growth. Diagnostic for not cooling: capacitor had failed on unit. Replaced capacitor with 5 year warranty. Verified system was cooling.

Recommend 
-install air purifier to mitigate bacterial growth
Upon arrival home owner states unit is running but not cooling. Checked float safety switch. Inspected indoor and outdoor coils. Inspected inside air handler cabinet. Interior cabinet is starting to accumulate bacterial growth. Diagnostic for not cooling: capacitor had failed on unit. Replaced capacitor with 5 year warranty. Verified system was cooling.

Recommend 
-install air purifier to mitigate bacterial growth
Nathan A.
Nathan A. Checked in
Upon arrival home owner states unit is running but not cooling. Checked float safety switch. Inspected indoor and outdoor coils. Inspected inside air handler cabinet. Interior cabinet is starting to accumulate bacterial growth. Diagnostic for not cooling: capacitor had failed on unit. Replaced capacitor with 5 year warranty. Verified system was cooling. Recommend -install air purifier to mitigate bacterial growth
Clearwater, FL 33764
Upon arrival home owner states unit is intermittently cooling. Found drain line and pan heavily backed up. Cleared drain line and drain pan. Added pan tabs to help with buildup. Verified system was draining and cooling. Discounted services as we were behind on time slot. Secondary drain pan is undersized for system. Would recommend sizing up pan.
Upon arrival home owner states unit is intermittently cooling. Found drain line and pan heavily backed up. Cleared drain line and drain pan. Added pan tabs to help with buildup. Verified system was draining and cooling. Discounted services as we were behind on time slot. Secondary drain pan is undersized for system. Would recommend sizing up pan.
Nathan A.
Nathan A. Checked in
Upon arrival home owner states unit is intermittently cooling. Found drain line and pan heavily backed up. Cleared drain line and drain pan. Added pan tabs to help with buildup. Verified system was draining and cooling. Discounted services as we were behind on time slot. Secondary drain pan is undersized for system. Would recommend sizing up pan.
Clearwater, FL 33755
Ricky O.
Ricky O. Checked in
Cleaned drain line and pan. Flushed with chemical. No further issues. Pressures good
Clearwater, FL 33765
Michael A.
Michael A. Checked in
Upon inspection found condenser not clicking on but evaporator blower was working. Found bad capacitor. Client opted to replace capacitor and system started up. Amp draws are good. Pressures and Subcool are great. Replaced filter for air handler. System is cooling.
Clearwater, FL 33756
Michael A.
Michael A. Checked in
Upon inspection, found blown 5 amp fuse. Replaced fuse and it blew again. Disconnected wires to condenser and replaced fuse with no issues. Reconnected contactar and fuse blew. Diagnosed bad contactar. Client agreed to replace and system is now working properly. Amp draws are good. System is cooling.
Clearwater, FL 33763
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to weak motor starter. Replaced part. Start and test. Checked pressures. Temp split good. Client is aware unit was flooded and the poor condition unit is in. Unit cooling at this time.
Clearwater, FL 33762
On arrival found unit cooling but float full of water. Client said unit has been shutting on and off. Cleared pans and drain. Added chemical to help prevent growth. Recommend twice a year maintenance for proper drainage. Unit cooling at this time.
On arrival found unit cooling but float full of water. Client said unit has been shutting on and off. Cleared pans and drain. Added chemical to help prevent growth. Recommend twice a year maintenance for proper drainage. Unit cooling at this time.
Justin G.
Justin G. Checked in
On arrival found unit cooling but float full of water. Client said unit has been shutting on and off. Cleared pans and drain. Added chemical to help prevent growth. Recommend twice a year maintenance for proper drainage. Unit cooling at this time.
Clearwater, FL 33759
water leak
Upon arrival, homeowner showed me two air handler, which was leaking water from the float switch port. Homeowner had taken drain line apart to manage water leak.

Vacuumed all water out of emergency drain pan and evaporator coil pan. Blew out condensate drain line. Cut off and replaced some couplings on drain line to improve pitch. Tested drain flow with warm water. Treated evaporator coil pan. Tested float switch. Tested system function after repair.
water leak
Upon arrival, homeowner showed me two air handler, which was leaking water from the float switch port. Homeowner had taken drain line apart to manage water leak.

Vacuumed all water out of emergency drain pan and evaporator coil pan. Blew out condensate drain line. Cut off and replaced some couplings on drain line to improve pitch. Tested drain flow with warm water. Treated evaporator coil pan. Tested float switch. Tested system function after repair.
Sha’nya B.
Sha’nya B. Checked in
water leak Upon arrival, homeowner showed me two air handler, which was leaking water from the float switch port. Homeowner had taken drain line apart to manage water leak. Vacuumed all water out of emergency drain pan and evaporator coil pan. Blew out condensate drain line. Cut off and replaced some couplings on drain line to improve pitch. Tested drain flow with warm water. Treated evaporator coil pan. Tested float switch. Tested system function after repair.
Clearwater, FL 33763
Bailey M.
Bailey M. Checked in
Upon my inspection, system was initially turned off at the breaker panel. Client told me that they were in the unit last week and the thermostat was set to 67° but it was reading 77° inside. Turned system on and inspected air handler. System was installed in 2014 and is a 2013 system. Indoor blower motor is pulling 1.6 amps and is rated for 1.3 amps. 7.5 mf capacitor tested good. Evaporator coils are dirty but not horrible. Temperature split is 14°. System pressures are indicating low on refrigerant. Capacitor needs to be replaced. Amp draws look good on the compressor and fan motor. Pressures indicate a leak in the system. System is low on refrigerant. After further inspection I noticed oil in the evaporator drain pan indicating a leak in the coil. Clients were given options of repair or replacement of the system. Creating quote for replacement. System is not running at this time.
Clearwater, FL 33764
Water leak
People in condo directly below made a complaint about water leaking from ceiling
Upon initial inspection found float switch, overflowing with water. Drain is clogged and float switch is bad. Cleared and cleaned condensate drain line. Treated evaporator coil pan. Replaced float switch.
Water leak
People in condo directly below made a complaint about water leaking from ceiling
Upon initial inspection found float switch, overflowing with water. Drain is clogged and float switch is bad. Cleared and cleaned condensate drain line. Treated evaporator coil pan. Replaced float switch.
Sha’nya B.
Sha’nya B. Checked in
Water leak People in condo directly below made a complaint about water leaking from ceiling Upon initial inspection found float switch, overflowing with water. Drain is clogged and float switch is bad. Cleared and cleaned condensate drain line. Treated evaporator coil pan. Replaced float switch.
Clearwater, FL 33763
No cool
Homeowner states the system has been working off and on over the past few days

Found water in float switch due to clogged
Vacuumed condensate drain line and pan
Cut and blew out drain line
Reattached, drain line and flushed line
Treated evaporator coil pan with viper spray and left pan tabs

Checked the refrigerant pressures and air temperature split. Tested capacitor, and cleaned out condenser electrical compartment. System is running well at this time.

Sent estimates for blower wheel and evaporator coil cleaning+ maintenance plan
No cool
Homeowner states the system has been working off and on over the past few days

Found water in float switch due to clogged
Vacuumed condensate drain line and pan
Cut and blew out drain line
Reattached, drain line and flushed line
Treated evaporator coil pan with viper spray and left pan tabs

Checked the refrigerant pressures and air temperature split. Tested capacitor, and cleaned out condenser electrical compartment. System is running well at this time.

Sent estimates for blower wheel and evaporator coil cleaning+ maintenance plan
Sha’nya B.
Sha’nya B. Checked in
No cool Homeowner states the system has been working off and on over the past few days Found water in float switch due to clogged Vacuumed condensate drain line and pan Cut and blew out drain line Reattached, drain line and flushed line Treated evaporator coil pan with viper spray and left pan tabs Checked the refrigerant pressures and air temperature split. Tested capacitor, and cleaned out condenser electrical compartment. System is running well at this time. Sent estimates for blower wheel and evaporator coil cleaning+ maintenance plan
Clearwater, FL 33761
Ricky O.
Ricky O. Checked in
Found unit leaking water into ceiling due to clogged drain and improper installation. I cut drain line and blew out with nitrogen. I sucked with vacuum as well. I then performed acid flush. I leveled unit and Repiped float. I moved aux pan into different position. Many issues with install client declined to address now but I’m sending quotes for future work. Unit is cooling and draining for now
Clearwater, FL 33759
Home owner attempted installing soft start kit and blew low voltage fuse in air handler. Explained we can not install client supplied equipment. Replaced fuse and verified operations. Unit is now cooling.
Home owner attempted installing soft start kit and blew low voltage fuse in air handler. Explained we can not install client supplied equipment. Replaced fuse and verified operations. Unit is now cooling.
Nathan A.
Nathan A. Checked in
Home owner attempted installing soft start kit and blew low voltage fuse in air handler. Explained we can not install client supplied equipment. Replaced fuse and verified operations. Unit is now cooling.
Clearwater, FL 33761
On arrival found unit not cooling due to low voltage thermostat wire being cut and disconnected from condenser. Cut and spliced new wire on roof. Capacitor checked good. Pressures good. Temp split good. Unit operating properly at this time.
On arrival found unit not cooling due to low voltage thermostat wire being cut and disconnected from condenser. Cut and spliced new wire on roof. Capacitor checked good. Pressures good. Temp split good. Unit operating properly at this time.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to low voltage thermostat wire being cut and disconnected from condenser. Cut and spliced new wire on roof. Capacitor checked good. Pressures good. Temp split good. Unit operating properly at this time.
Clearwater, FL 33762
Upon arrival home owner states unit is intermittently cooling. Found blower motor to air handler had failed. Home owner states multiple power outages and leg of power lost to home. Fluctuating power can cause an ECM motor to fail. Would recommend reaching out to power company. Installed temporary motor. Will call manufacture for warranty and availability. Unit is currently cooling
Upon arrival home owner states unit is intermittently cooling. Found blower motor to air handler had failed. Home owner states multiple power outages and leg of power lost to home. Fluctuating power can cause an ECM motor to fail. Would recommend reaching out to power company. Installed temporary motor. Will call manufacture for warranty and availability. Unit is currently cooling
Nathan A.
Nathan A. Checked in
Upon arrival home owner states unit is intermittently cooling. Found blower motor to air handler had failed. Home owner states multiple power outages and leg of power lost to home. Fluctuating power can cause an ECM motor to fail. Would recommend reaching out to power company. Installed temporary motor. Will call manufacture for warranty and availability. Unit is currently cooling
Clearwater, FL 33767
no cool
Upon arrival, homeowner explained the system has not quite been cooling down to the desired temperature. Indoor air temperature is 76° and request is 72°.
After diagnosis, system is very low on refrigerant. Added 3 pounds of our 410 a today to get system cooling. Advised homeowner to fix this issue they will have a leak search and then replace the part that is leaking. 
Spoke with homeowner about system replacement options. Will send estimates for both.
Financing options for system replacement- 0% interest 
18 months-  $9100
60 months- $9700
no cool
Upon arrival, homeowner explained the system has not quite been cooling down to the desired temperature. Indoor air temperature is 76° and request is 72°.
After diagnosis, system is very low on refrigerant. Added 3 pounds of our 410 a today to get system cooling. Advised homeowner to fix this issue they will have a leak search and then replace the part that is leaking. 
Spoke with homeowner about system replacement options. Will send estimates for both.
Financing options for system replacement- 0% interest 
18 months-  $9100
60 months- $9700
Sha’nya B.
Sha’nya B. Checked in
no cool Upon arrival, homeowner explained the system has not quite been cooling down to the desired temperature. Indoor air temperature is 76° and request is 72°. After diagnosis, system is very low on refrigerant. Added 3 pounds of our 410 a today to get system cooling. Advised homeowner to fix this issue they will have a leak search and then replace the part that is leaking. Spoke with homeowner about system replacement options. Will send estimates for both. Financing options for system replacement- 0% interest 18 months- $9100 60 months- $9700
Clearwater, FL 33756
Upon arrival, we found the thermostat was not reaching desired temperature for the past few weeks. At first glance, we noticed both return filters were completely impacted and needed replacement. Tenant was notified. Upon further inspection, our pressure readings indicated a leak in the system. Tenant agreed to pay for the leak search. We found the leak within the evaporator coils. The air handler is a Goodman and is 10 years old while the condenser is a Goodman at 3 years old. We need to verify if the air handler is under warranty in order to quote a proper price to replace the coil. Tenant was notified and owner will need to call the office in order to schedule a call to discuss options. As of now, tenant replaced the filters and will be waiting for further approval and scheduling with the owner.
Upon arrival, we found the thermostat was not reaching desired temperature for the past few weeks. At first glance, we noticed both return filters were completely impacted and needed replacement. Tenant was notified. Upon further inspection, our pressure readings indicated a leak in the system. Tenant agreed to pay for the leak search. We found the leak within the evaporator coils. The air handler is a Goodman and is 10 years old while the condenser is a Goodman at 3 years old. We need to verify if the air handler is under warranty in order to quote a proper price to replace the coil. Tenant was notified and owner will need to call the office in order to schedule a call to discuss options. As of now, tenant replaced the filters and will be waiting for further approval and scheduling with the owner.
Justin G.
Justin G. Checked in
Upon arrival, we found the thermostat was not reaching desired temperature for the past few weeks. At first glance, we noticed both return filters were completely impacted and needed replacement. Tenant was notified. Upon further inspection, our pressure readings indicated a leak in the system. Tenant agreed to pay for the leak search. We found the leak within the evaporator coils. The air handler is a Goodman and is 10 years old while the condenser is a Goodman at 3 years old. We need to verify if the air handler is under warranty in order to quote a proper price to replace the coil. Tenant was notified and owner will need to call the office in order to schedule a call to discuss options. As of now, tenant replaced the filters and will be waiting for further approval and scheduling with the owner.
Clearwater, FL 33764
Justin G.
Justin G. Checked in
Performed an evaporator coil pull and clean. Verified no leaks and unit is running properly with a clean coil at this time. Performed a chemical drain line cleaning/treatment. Added refrigerant to achieve factory specs.