Instant Quote Shop Filters Call Air Bros

Clearwater, FL

air-bros-team-with-truck

Expert Cooling, Heating and Electrical In Clearwater, FL

If you've lived in Clearwater for any length of time, you already know what August feels like when the AC goes out. It's not just uncomfortable — it's the kind of heat that makes an hour feel like a day. We started Air Bros because we grew up here, and we got tired of seeing neighbors get burned by out-of-town companies that didn't understand the difference between a Phoenix summer and a Gulf Coast one.

Clearwater's combination of salt air, nine months of cooling season, and humidity that rarely lets up puts real stress on HVAC equipment. We know this market, we know these homes, and we've seen firsthand what happens when the wrong company installs the wrong system for this climate. We're here to make sure that doesn't happen to you.

Professional AC Repair in Clearwater

When your AC stops working in Clearwater, waiting isn't an option. Temperatures and humidity make an uncomfortable home unbearable within hours, and in the middle of summer, same-day availability matters more than almost anything else.

Air Bros offers same-day Air Conditioning Repair throughout Clearwater and Clearwater Beach for all major brands and models. Our technicians diagnose and repair refrigerant leaks, failed capacitors, frozen evaporator coils, blower motor failures, faulty thermostats, and electrical faults. We arrive with a fully stocked truck so most repairs are completed in a single visit.

Homes near the Gulf are exposed to salt air that corrodes coil fins and electrical contacts faster than inland properties. We inspect for corrosion damage on every repair call and address it before it leads to a larger failure. All pricing is upfront and flat-rate before any work begins — no surprises when the job is done.

The Importance of Proper AC Installation

Choosing the right AC system for a Clearwater home requires more than picking a brand. It requires sizing the unit correctly for Florida's Climate Zone 2 and selecting equipment built to handle high humidity and extended run times. These are decisions that affect how comfortable your home feels and how much you spend on energy bills for the next decade.

An undersized system will run constantly without ever adequately dehumidifying your home. An oversized system will short-cycle, leaving excess moisture in the air and wearing out components prematurely. Either way, the wrong size costs you money every month and shortens the life of your equipment.

Air Bros installs Trane, Carrier, Lennox, and Daikin systems selected specifically for Gulf Coast performance. We recommend variable-speed compressors that manage humidity more effectively than single-stage units and run more quietly and efficiently over the long haul. Every AC System Replacement is permitted through Pinellas County and completed to Florida building code. We also walk you through available financing options and energy efficiency incentives before any contract is signed.

Why AC Maintenance in Clearwater is Paramount

In most of the country, annual AC maintenance is considered sufficient. In Clearwater, twice a year is the standard — and for good reason.

With a cooling season that runs from March through November, your system accumulates wear, dirt, and biological growth at a pace that a single annual visit can't keep up with. Neglected drain lines back up and cause water damage. Dirty coils make your system work harder and drive up your electric bill. Small issues that a technician would catch in April become expensive failures in July. Air Bros recommends a spring tune-up before peak cooling demand and a fall visit before humidity season winds down.

Each HVAC Maintenance visit includes coil cleaning, refrigerant level check, electrical inspection, condensate drain flush, and a corrosion assessment for properties near the water. For vacation rental owners and property managers on Clearwater Beach, we offer preventive maintenance contracts to reduce the risk of mid-booking breakdowns.

For homeowners who want year-round peace of mind, the Air Bros Premium Membership covers both visits for just $18 per month. Members pay no service call fees, get 10% off all repairs, have no overtime charges, and move to the front of the line with priority booking. In a market where a mid-August breakdown means competing with every other Clearwater home for a same-day technician, that priority access alone is worth it. If you're tired of reacting to problems and ready to get ahead of them, the membership is the most cost-effective way to keep your system running through whatever the Gulf Coast throws at it.

Why Clearwater Homeowners Choose Air Bros

We pull permits on every installation through Pinellas County, which protects your home's value and ensures your system is installed to code. Our pricing is upfront and flat-rate — you'll know the full cost before we start, with no surprise charges after the job is done.

Emergency service is available around the clock, including weekends and holidays, because AC failures don't wait for business hours. We service hundreds of beach properties annually and know exactly how to protect equipment from salt air corrosion and Florida humidity. When you call Air Bros, you're talking to someone who knows Clearwater — not a call center routing your ticket to whoever is available. If you have questions about our services, visit our HVAC FAQs page or contact us directly.

Clearwater's climate doesn't give your AC a break, and neither do we. Whether you're dealing with an unexpected breakdown, planning a new installation, or just staying ahead of the season, Air Bros is built for exactly this market. We've earned the trust of Clearwater homeowners by showing up on time, pricing honestly, and doing the job right the first time.

If you need AC Repair, AC Installation, or AC Maintenance, you can rely on Air Bros to take care of Clearwater. Call us today at 727-217-6148 to schedule your appointment.

How often should I service my AC in Clearwater, FL?

In Clearwater and throughout Florida, HVAC systems should be serviced twice per year — once in spring before the heavy cooling season, and once in fall. Florida's near-continuous cooling demand and high humidity place significantly more stress on AC systems than in northern states, making semi-annual maintenance essential rather than optional.

Why do AC systems near Clearwater Beach fail faster?

Properties within a few miles of the Gulf are exposed to salt air that accelerates corrosion on condenser coils, copper lines, and electrical contacts. This can reduce equipment lifespan by three to five years compared to inland Clearwater homes. Annual coil cleaning and corrosion-resistant coatings cost far less than early system replacement.

What HVAC brands work best in Clearwater's humid climate?

For Clearwater's high humidity and long cooling seasons, systems with strong dehumidification performance are the priority. Top performers include Trane, Carrier, Lennox, and Daikin — all offering units rated for Florida's Climate Zone 2. Variable-speed compressors are especially effective at controlling indoor humidity in Gulf Coast climates.

Do you service vacation rental properties in Clearwater Beach?

Yes. We work with many vacation rental owners and property managers throughout Clearwater Beach and the barrier islands. We prioritize fast turnaround on rental properties and offer preventive maintenance contracts to reduce mid-booking breakdowns.

Does humidity in Clearwater cause mold problems in AC systems?

Clearwater's year-round humidity creates ideal conditions for mold and biological growth inside air handlers, evaporator coils, and drain pans. Left unchecked, this circulates through your home's air and can cause health issues for residents. Air Bros inspects for mold and biological buildup on every maintenance visit and recommends UV light air purifiers for homes that have had recurring issues.

Is it worth replacing my AC system before hurricane season in Clearwater?

If your system is more than ten years old or has needed repeated repairs, replacing it before hurricane season is worth serious consideration. A storm doesn't just risk physical damage to your outdoor unit — the power surges and outages that follow can push an already-stressed system over the edge. Air Bros can assess your current system and give you an honest recommendation on whether repair or replacement makes more sense heading into June.

Recent Jobs and Reviews in Clearwater, FL

Clearwater, FL at a glance

Air Bros Air Conditioning & Electrical has completed 25 jobs in Clearwater, FL between September 2025 and November 2025.

The most recent job was on November 24, 2025.

Air Bros Air Conditioning & Electrical has completed 176 jobs in Clearwater, FL in the last 12 months. The first job there was in February 2025.

Job Locations and Reviews

2 Ton RUUD Condenser and First Co. Air Handler. 
Return Duct replacement 
~ Cash price
~ 3 year labor warranty
~ 10 year parts warranty
- Installation of pancake air handler unit in ceiling 
- Install Accessible drain clean out 
- New safety float switch
- New insulation on copper at unit
- Remove old duct board and replace and seal with new duct board
- Installation of Condenser unit
- New Hurricane pad
- New Hurricane straps
- New UV rated insulation on copper
- New filter line dryer
100% satisfaction
2 Ton RUUD Condenser and First Co. Air Handler. 
Return Duct replacement 
~ Cash price
~ 3 year labor warranty
~ 10 year parts warranty
- Installation of pancake air handler unit in ceiling 
- Install Accessible drain clean out 
- New safety float switch
- New insulation on copper at unit
- Remove old duct board and replace and seal with new duct board
- Installation of Condenser unit
- New Hurricane pad
- New Hurricane straps
- New UV rated insulation on copper
- New filter line dryer
100% satisfaction
Kyle K.
Kyle K. Checked in
2 Ton RUUD Condenser and First Co. Air Handler. Return Duct replacement ~ Cash price ~ 3 year labor warranty ~ 10 year parts warranty - Installation of pancake air handler unit in ceiling - Install Accessible drain clean out - New safety float switch - New insulation on copper at unit - Remove old duct board and replace and seal with new duct board - Installation of Condenser unit - New Hurricane pad - New Hurricane straps - New UV rated insulation on copper - New filter line dryer 100% satisfaction
Clearwater, FL 33762
Installed new compressor wire harness. Verified operations. System is cooling at this time. No guarantee that the issue won’t happen again.
Installed new compressor wire harness. Verified operations. System is cooling at this time. No guarantee that the issue won’t happen again.
Michael A.
Michael A. Checked in
Installed new compressor wire harness. Verified operations. System is cooling at this time. No guarantee that the issue won’t happen again.
Clearwater, FL 33761
Performed Maitenence on system. No access to water outside, therefore could not clean condenser coils. Notified Hailey that in 6 months if they can get water access outside, we will be able to clean the condenser coils. 
Replaced service disconnect at condenser. 
Zip tied the panel shut so that no one can easily tamper with it. 
Installed new Hurricane straps on the unit and repositioned it on the concrete pad. 
Notified client that they need to install a new filter in their system as there is none at this time. Evaporator coils are at risk of getting dirty and impacted with debris. This will cause inefficiency and eventually will need a deep cleaning. 
System is cooling at this time.
Performed Maitenence on system. No access to water outside, therefore could not clean condenser coils. Notified Hailey that in 6 months if they can get water access outside, we will be able to clean the condenser coils. 
Replaced service disconnect at condenser. 
Zip tied the panel shut so that no one can easily tamper with it. 
Installed new Hurricane straps on the unit and repositioned it on the concrete pad. 
Notified client that they need to install a new filter in their system as there is none at this time. Evaporator coils are at risk of getting dirty and impacted with debris. This will cause inefficiency and eventually will need a deep cleaning. 
System is cooling at this time.
Michael A.
Michael A. Checked in
Performed Maitenence on system. No access to water outside, therefore could not clean condenser coils. Notified Hailey that in 6 months if they can get water access outside, we will be able to clean the condenser coils. Replaced service disconnect at condenser. Zip tied the panel shut so that no one can easily tamper with it. Installed new Hurricane straps on the unit and repositioned it on the concrete pad. Notified client that they need to install a new filter in their system as there is none at this time. Evaporator coils are at risk of getting dirty and impacted with debris. This will cause inefficiency and eventually will need a deep cleaning. System is cooling at this time.
Clearwater, FL 33756
Upon my inspection, found compressor wiring harness was disconnected from compressor and shows heavy signs of corrosion and failure. Returning in the morning to replace wiring harness. Capacitor tested within factory spec and Contactar looks good. Replacing this wiring harness offers no guarantee that there is no issue with the compressor. We will determine the condition of the compressor after the new harness is installed.
Upon my inspection, found compressor wiring harness was disconnected from compressor and shows heavy signs of corrosion and failure. Returning in the morning to replace wiring harness. Capacitor tested within factory spec and Contactar looks good. Replacing this wiring harness offers no guarantee that there is no issue with the compressor. We will determine the condition of the compressor after the new harness is installed.
Michael A.
Michael A. Checked in
Upon my inspection, found compressor wiring harness was disconnected from compressor and shows heavy signs of corrosion and failure. Returning in the morning to replace wiring harness. Capacitor tested within factory spec and Contactar looks good. Replacing this wiring harness offers no guarantee that there is no issue with the compressor. We will determine the condition of the compressor after the new harness is installed.
Clearwater, FL 33761
Upon my inspection, found system to be low on refrigerant. Added 3 pounds of 410 a refrigerant to achieve proper sub cool. Verified system in both heating and cooling. System is cooling and heating properly at this time. 
If there is a leak in the system, we will have to perform a leak search and make the necessary repairs. The client understands this is a starting point and that there may be future repairs if the system is low on refrigerant again.
Upon my inspection, found system to be low on refrigerant. Added 3 pounds of 410 a refrigerant to achieve proper sub cool. Verified system in both heating and cooling. System is cooling and heating properly at this time. 
If there is a leak in the system, we will have to perform a leak search and make the necessary repairs. The client understands this is a starting point and that there may be future repairs if the system is low on refrigerant again.
Michael A.
Michael A. Checked in
Upon my inspection, found system to be low on refrigerant. Added 3 pounds of 410 a refrigerant to achieve proper sub cool. Verified system in both heating and cooling. System is cooling and heating properly at this time. If there is a leak in the system, we will have to perform a leak search and make the necessary repairs. The client understands this is a starting point and that there may be future repairs if the system is low on refrigerant again.
Clearwater, FL 33761
2008 2.5T System 1400sf 

Air handler 
-motor severely hot and smells like electrical 
-capacitor failed 
-bacterial growth accumulating inside air handler 
-air handler coils severely rusted 

Condenser 
-compressor overheated when I arrived. Has been trying to run but due to failed capacitor/motor causing compressor to overheat. 
-outdoor coils have heavy corrosion and see through. Looks as if pet has been urinating on system 

Minimal Repair 
-replace air handler motor 
-replace capacitor 
-sanitize blower wheel 

Explained that I can not guarantee how long repair would last with underlying conditions of system. Or if any further issues present after completing repair.
2008 2.5T System 1400sf 

Air handler 
-motor severely hot and smells like electrical 
-capacitor failed 
-bacterial growth accumulating inside air handler 
-air handler coils severely rusted 

Condenser 
-compressor overheated when I arrived. Has been trying to run but due to failed capacitor/motor causing compressor to overheat. 
-outdoor coils have heavy corrosion and see through. Looks as if pet has been urinating on system 

Minimal Repair 
-replace air handler motor 
-replace capacitor 
-sanitize blower wheel 

Explained that I can not guarantee how long repair would last with underlying conditions of system. Or if any further issues present after completing repair.
Nathan A.
Nathan A. Checked in
2008 2.5T System 1400sf Air handler -motor severely hot and smells like electrical -capacitor failed -bacterial growth accumulating inside air handler -air handler coils severely rusted Condenser -compressor overheated when I arrived. Has been trying to run but due to failed capacitor/motor causing compressor to overheat. -outdoor coils have heavy corrosion and see through. Looks as if pet has been urinating on system Minimal Repair -replace air handler motor -replace capacitor -sanitize blower wheel Explained that I can not guarantee how long repair would last with underlying conditions of system. Or if any further issues present after completing repair.
Clearwater, FL 33764
On arrival found unit not cooling due to low refrigerant. Heard outdoor coil leaking. Condenser coil is leaking in multiple spots and must be replaced. Recommend not to fill at this time due to severity of leak. Will submit estimate for coil replacement. Unit does not cool.
On arrival found unit not cooling due to low refrigerant. Heard outdoor coil leaking. Condenser coil is leaking in multiple spots and must be replaced. Recommend not to fill at this time due to severity of leak. Will submit estimate for coil replacement. Unit does not cool.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to low refrigerant. Heard outdoor coil leaking. Condenser coil is leaking in multiple spots and must be replaced. Recommend not to fill at this time due to severity of leak. Will submit estimate for coil replacement. Unit does not cool.
Clearwater, FL 33760
Replaced two condenser disconnects.
Replaced two condenser disconnects.
Michael A.
Michael A. Checked in
Replaced two condenser disconnects.
Clearwater, FL 33767
Performed Maitenence on 2 systems. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Made sure all connections are tight. Systems are cooling with a 20° temperature split at this time. 

Notes: Drain lines are severely clogged up and very hard to clean even with nitrogen. If drain issue evolves in the future, we will recommend a harsh overnight chemical treatment on drain system or replacing the drain line with new pvc or installing condensate pumps. 

Advised client to change filters asap.
Performed Maitenence on 2 systems. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Made sure all connections are tight. Systems are cooling with a 20° temperature split at this time. 

Notes: Drain lines are severely clogged up and very hard to clean even with nitrogen. If drain issue evolves in the future, we will recommend a harsh overnight chemical treatment on drain system or replacing the drain line with new pvc or installing condensate pumps. 

Advised client to change filters asap.
Michael A.
Michael A. Checked in
Performed Maitenence on 2 systems. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Made sure all connections are tight. Systems are cooling with a 20° temperature split at this time. Notes: Drain lines are severely clogged up and very hard to clean even with nitrogen. If drain issue evolves in the future, we will recommend a harsh overnight chemical treatment on drain system or replacing the drain line with new pvc or installing condensate pumps. Advised client to change filters asap.
Clearwater, FL 33767
Clearwater, FL - Replace LPCS Low pressure cut off switch. System is cooling properly at this time.
Michael A.
Michael A. Checked in
Replace LPCS Low pressure cut off switch. System is cooling properly at this time.
Clearwater, FL 33759
Upon my inspection, found system giving fault codes. Installed hard start kit to remove one fault code for compressor over amping in start up. Next fault code is for low pressure switch. Bypassed pressure switch for the moment but need to replace. System is cooling with a 20° temp split at this time. 
Compressor is at risk of failure. There is no guarantee this system will continue to cool properly. The hard start kit is a remedy but not a permanent solution.
Upon my inspection, found system giving fault codes. Installed hard start kit to remove one fault code for compressor over amping in start up. Next fault code is for low pressure switch. Bypassed pressure switch for the moment but need to replace. System is cooling with a 20° temp split at this time. 
Compressor is at risk of failure. There is no guarantee this system will continue to cool properly. The hard start kit is a remedy but not a permanent solution.
Michael A.
Michael A. Checked in
Upon my inspection, found system giving fault codes. Installed hard start kit to remove one fault code for compressor over amping in start up. Next fault code is for low pressure switch. Bypassed pressure switch for the moment but need to replace. System is cooling with a 20° temp split at this time. Compressor is at risk of failure. There is no guarantee this system will continue to cool properly. The hard start kit is a remedy but not a permanent solution.
Clearwater, FL 33759
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Compressor start up amp draw is 10 amps over the max rating. Checked amp draw on fan motor. Checked capacitor is within factory range. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. 

Duct work is old and has holes. House has higher humidity and growth smell. Recommending replacement.
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Compressor start up amp draw is 10 amps over the max rating. Checked amp draw on fan motor. Checked capacitor is within factory range. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. 

Duct work is old and has holes. House has higher humidity and growth smell. Recommending replacement.
Michael A.
Michael A. Checked in
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Compressor start up amp draw is 10 amps over the max rating. Checked amp draw on fan motor. Checked capacitor is within factory range. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. Duct work is old and has holes. House has higher humidity and growth smell. Recommending replacement.
Clearwater, FL 33764
Justin G.
Justin G. Checked in
Replacement of entire duct system to new energy star rated R6 flex duct, including: -Permits -Removal of all existing ducts, plenums, mixing boxes, grilles and boots -Drywall repair included -New plenums and heat shields -New flex duct and boots -New mixing boxes -New grilles -All ducts sealed to code -All ducts strapped properly to code -Add return ducts to 3 bedrooms -Test and balance system for proper air flow The newly installed ductwork is designed for improved energy efficiency, reducing air leaks and optimizing HVAC system performance. This upgrade meets industry standards for energy efficiency, contributing to lower energy consumption and enhanced system operation.
Clearwater, FL 33764
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. 
Verified heating functions. 
Duct work is original with the house
No surge protection installed
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. 
Verified heating functions. 
Duct work is original with the house
No surge protection installed
Michael A.
Michael A. Checked in
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. Verified heating functions. Duct work is original with the house No surge protection installed
Clearwater, FL 33761
Justin G.
Justin G. Checked in
Inspection report stated duct disconnected in attic. Found flex duct to mixing box detached. Attached duct. Sealed to code. Airflow proper upstairs. Found evaporator coil to be impacted. Will return to perform pull and clean. Unit cooling.
Clearwater, FL 33760
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Fan motor is over amping at 1.34 amps. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. 

Found major leaked in existing old duct work. Quoting for full replacement.
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Fan motor is over amping at 1.34 amps. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. 

Found major leaked in existing old duct work. Quoting for full replacement.
Michael A.
Michael A. Checked in
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Fan motor is over amping at 1.34 amps. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. Found major leaked in existing old duct work. Quoting for full replacement.
Clearwater, FL 33764
Justin G.
Justin G. Checked in
Performed bi annual maintenance. Replaced bulb. Unit cooling.
Clearwater, FL 33767
Home owner states unit is not cooling at all. He changed batteries to Thermostat. Found thermostat hard wired and low voltage fuse blown. Explained we would need to do low voltage short test. Found high voltage to rooftop unit shorted against contactor. Contactor coil failed causing fuse to blow. Replaced contactor and taped all potential short fail points. Replaced in line fuse. Verified system is cooling.
Home owner states unit is not cooling at all. He changed batteries to Thermostat. Found thermostat hard wired and low voltage fuse blown. Explained we would need to do low voltage short test. Found high voltage to rooftop unit shorted against contactor. Contactor coil failed causing fuse to blow. Replaced contactor and taped all potential short fail points. Replaced in line fuse. Verified system is cooling.
Nathan A.
Nathan A. Checked in
Home owner states unit is not cooling at all. He changed batteries to Thermostat. Found thermostat hard wired and low voltage fuse blown. Explained we would need to do low voltage short test. Found high voltage to rooftop unit shorted against contactor. Contactor coil failed causing fuse to blow. Replaced contactor and taped all potential short fail points. Replaced in line fuse. Verified system is cooling.
Clearwater, FL 33767
Upon my inspection, found clogged primary drain pan and drain line. Also discovered growth on the blower wheel and recommended both cleaning/treatments. Performed a blower removal and cleaning, drain line/primary drain pan cleaning, wiped down all plastics and verified system is cooling properly at this time. Client is now on Maitenence plan.
Upon my inspection, found clogged primary drain pan and drain line. Also discovered growth on the blower wheel and recommended both cleaning/treatments. Performed a blower removal and cleaning, drain line/primary drain pan cleaning, wiped down all plastics and verified system is cooling properly at this time. Client is now on Maitenence plan.
Michael A.
Michael A. Checked in
Upon my inspection, found clogged primary drain pan and drain line. Also discovered growth on the blower wheel and recommended both cleaning/treatments. Performed a blower removal and cleaning, drain line/primary drain pan cleaning, wiped down all plastics and verified system is cooling properly at this time. Client is now on Maitenence plan.
Clearwater, FL 33759
Return to complete scope of work 

Install primary safety overflow switch 
Install air purifier 

Verified system operations after completing 

Home owner noticing growth in playroom vent. Will update estimate to replace boot and grill
Return to complete scope of work 

Install primary safety overflow switch 
Install air purifier 

Verified system operations after completing 

Home owner noticing growth in playroom vent. Will update estimate to replace boot and grill
Nathan A.
Nathan A. Checked in
Return to complete scope of work Install primary safety overflow switch Install air purifier Verified system operations after completing Home owner noticing growth in playroom vent. Will update estimate to replace boot and grill
Clearwater, FL 33763
Ricky O.
Ricky O. Checked in
Arrived onsite and checked in with tenant. Found system not cooling due to safety float switch tripped. Inside drain pan filled with gunk. I cleaned drain line and inner drain pan. I treated and sanitized pan as well. I then performed system tune up. No further issues found. Unit is operating properly at this time
Clearwater, FL 33764
On arrival found unit having condensation issue. Found coil in air handler installed incorrectly causing condensation blow off. Recommend to remove blower and install baffle assemble correctly to prevent water blow off. Client declined repairs at this time. Adjusted airflow back to 300 can per ton to help with condensation issue in meantime. Client wants to call company who installed to fix unit. Unit cooling at this time.
On arrival found unit having condensation issue. Found coil in air handler installed incorrectly causing condensation blow off. Recommend to remove blower and install baffle assemble correctly to prevent water blow off. Client declined repairs at this time. Adjusted airflow back to 300 can per ton to help with condensation issue in meantime. Client wants to call company who installed to fix unit. Unit cooling at this time.
Justin G.
Justin G. Checked in
On arrival found unit having condensation issue. Found coil in air handler installed incorrectly causing condensation blow off. Recommend to remove blower and install baffle assemble correctly to prevent water blow off. Client declined repairs at this time. Adjusted airflow back to 300 can per ton to help with condensation issue in meantime. Client wants to call company who installed to fix unit. Unit cooling at this time.
Clearwater, FL 33761
Replace 5 switches three for the living room area 1 in the kitchen and 1 for the bathroom light  
Replace bulbs in the kitchen and living area 
Replaced bulbs in the office and the garage door opener 
Reworked a three way switch for the overhead kitchen lights
Replace 5 switches three for the living room area 1 in the kitchen and 1 for the bathroom light  
Replace bulbs in the kitchen and living area 
Replaced bulbs in the office and the garage door opener 
Reworked a three way switch for the overhead kitchen lights
Griffin K.
Griffin K. Checked in
Replace 5 switches three for the living room area 1 in the kitchen and 1 for the bathroom light Replace bulbs in the kitchen and living area Replaced bulbs in the office and the garage door opener Reworked a three way switch for the overhead kitchen lights
Clearwater, FL 33764
Upon arrival home owner states secondary pan is backing up. Found drain line heavily clogged, primary pan full, and secondary pan. Nitrogen purged drain line. Cleared secondary and primary drain pan. 

Bacterial growth accumulating on blower wheel and assembly. Home owners stated another company sanitized the wheel and ducts. 

Found ductwork not strapped/sealed properly. Found 7” boot/flex not sealed properly. Recommend replacing boot and sealing all ducts. 

Recommend adding air purifier to mitigate bacterial growth. 

Air handler does not have a primary safety overflow switch. Need to install as they only have a backup switch. 

Verified system was draining and cooling
Upon arrival home owner states secondary pan is backing up. Found drain line heavily clogged, primary pan full, and secondary pan. Nitrogen purged drain line. Cleared secondary and primary drain pan. 

Bacterial growth accumulating on blower wheel and assembly. Home owners stated another company sanitized the wheel and ducts. 

Found ductwork not strapped/sealed properly. Found 7” boot/flex not sealed properly. Recommend replacing boot and sealing all ducts. 

Recommend adding air purifier to mitigate bacterial growth. 

Air handler does not have a primary safety overflow switch. Need to install as they only have a backup switch. 

Verified system was draining and cooling
Nathan A.
Nathan A. Checked in
Upon arrival home owner states secondary pan is backing up. Found drain line heavily clogged, primary pan full, and secondary pan. Nitrogen purged drain line. Cleared secondary and primary drain pan. Bacterial growth accumulating on blower wheel and assembly. Home owners stated another company sanitized the wheel and ducts. Found ductwork not strapped/sealed properly. Found 7” boot/flex not sealed properly. Recommend replacing boot and sealing all ducts. Recommend adding air purifier to mitigate bacterial growth. Air handler does not have a primary safety overflow switch. Need to install as they only have a backup switch. Verified system was draining and cooling
Clearwater, FL 33763
Justin G.
Justin G. Checked in
On arrival found unit not cooling properly due to clogged drain and pump. Cleared pan and drain. Performed maintenance on system. Found unit to be set to very low blower speed causing a higher temp split and condensation issues. Adjusted blower back to factory settings. Unit has 21* split. Unit cooling properly at this time .
Clearwater, FL 33761

Contact the Bros You Know Today!

Gravity Forms Pagination Must be Steps