Expert HVAC Services in Palm Harbor, FL

Palm Harbor is one of those places that doesn’t need a city hall to have a strong sense of community. As one of Pinellas County’s largest unincorporated areas, it has grown on its own terms — established neighborhoods, mature tree canopies, and homeowners who have been here long enough to know what the Florida heat actually costs them. We started Air Bros because we grew up in this area, and we understand the difference between servicing a newer Clearwater Beach condo and a 1980s Palm Harbor home that has never had its ductwork touched.

The combination of Lake Tarpon’s moisture, proximity to the Gulf, and Palm Harbor’s tree cover creates a humidity profile that is relentless on HVAC equipment. We know these streets, we know these homes, and we’ve seen firsthand what happens when the wrong system gets installed in the wrong house. We’re here to make sure that doesn’t happen to you.

AC Repair in Palm Harbor

When your AC stops working in Palm Harbor, the heat moves in fast. Humidity near Lake Tarpon and the surrounding waterways makes an uncomfortable home unbearable within hours, and in the middle of summer, same-day availability matters more than almost anything else.

Air Bros offers same-day Air Conditioning Repair throughout Palm Harbor for all major brands and models. Our technicians diagnose and repair refrigerant leaks, failed capacitors, frozen evaporator coils, blower motor failures, faulty thermostats, and electrical faults. We arrive with a fully stocked truck so most repairs are completed in a single visit.

Palm Harbor’s older housing stock means we regularly encounter systems that have been patched together over the years — mismatched components, outdated refrigerants, and wiring that wasn’t designed for today’s equipment. We assess the full picture on every repair call and give you an honest recommendation on whether repair or replacement makes more sense for your situation. All pricing is upfront and flat-rate before any work begins.

Ductless AC in Palm Harbor

A significant portion of Palm Harbor’s homes were built before modern ducted HVAC systems were standard, and many have additions, converted garages, or Florida rooms that were never tied into the main system. For these spaces, ductless AC is not just a convenience — it is often the most practical and cost-effective solution available.

Ductless mini-split systems allow Air Bros to cool individual rooms or zones without the expense and disruption of running new ductwork through established walls and ceilings. They are quieter than traditional systems, more energy efficient, and give homeowners precise control over temperature in each space. For Palm Harbor homes near Lake Tarpon where humidity infiltration through aging ductwork is a recurring problem, eliminating the ducts entirely removes one of the most common sources of moisture and air quality issues.

Air Bros installs and services all major ductless brands and can assess whether a single-zone or multi-zone system is the right fit for your home. Every AC System Replacement and new installation is permitted through Pinellas County and completed to Florida building code. We also walk you through available financing options before any contract is signed.

Indoor Air Quality in Palm Harbor

Palm Harbor’s mature landscaping, proximity to Lake Tarpon, and year-round humidity create conditions that make indoor air quality a genuine health concern — not just a comfort issue. Mold spores, pollen, dust mites, and airborne allergens thrive in Florida’s climate, and without the right filtration and ventilation, your AC system recirculates them through your home every time it runs.

Older Palm Harbor homes are particularly vulnerable. Aging ductwork develops leaks that pull unconditioned air — and everything in it — directly into your living spaces. Poorly sealed crawl spaces and attics compound the problem, introducing moisture and biological growth that standard filters were never designed to catch.

Air Bros offers a full range of Indoor Air Quality solutions including UV light air purifiers, whole-home dehumidifiers, and advanced filtration systems matched to your home’s specific needs. For Palm Harbor families dealing with allergies, asthma, or recurring mold issues, addressing air quality at the system level is the most effective long-term solution. We also walk you through available financing options so cost is never the reason a problem goes unaddressed.

Why Palm Harbor Homeowners Choose Air Bros

We pull permits on every installation through Pinellas County, which protects your home’s value and ensures your system is installed to code. Our pricing is upfront and flat-rate — you’ll know the full cost before we start, with no surprise charges after the job is done.

Emergency service is available around the clock, including weekends and holidays, because AC failures don’t wait for business hours. We service homes throughout Palm Harbor, from the waterfront properties on Lake Tarpon to the established neighborhoods off US-19. When you call Air Bros, you’re talking to someone who knows Palm Harbor — not a call center routing your ticket to whoever is available. If you have questions about our services, visit our HVAC FAQs page or contact us directly.

Clearwater’s climate doesn’t give your AC a break, and neither do we. Whether you’re dealing with an unexpected breakdown, looking for a smarter way to cool a room that was never properly conditioned, or concerned about what your family is breathing, Air Bros is built for exactly this market. We’ve earned the trust of Palm Harbor homeowners by showing up on time, pricing honestly, and doing the job right the first time.

If you need AC Repair, Ductless AC, or Indoor Air Quality services, you can rely on Air Bros to take care of Palm Harbor. Call us today at 727-217-6148 to schedule your appointment.

Recent Jobs and Reviews in Palm Harbor, FL

Palm Harbor, FL at a glance

Air Bros Air Conditioning & Electrical has completed 25 jobs in Palm Harbor, FL between July 2026 and October 2026.

The most recent job was on October 6, 2026.

Air Bros Air Conditioning & Electrical has completed 35 jobs in Palm Harbor, FL in the last 12 months. The first job there was in April 2025.

Job Locations and Reviews

Griffin K.
Griffin K. Checked in
Found a loose ground connection in switch box and capped off outside receptacle because it had no power and improper box
Palm Harbor, FL 34683
Install 3 ton ruud heat pump 15 seer 
Install new condenser 
*Install 36in Miami dade hurricane pad 
Install new suction line insulation 
Install new vertical air handler 
Custom fabrication of supply plenum (reuse materials)
*Install new insulated stand 
*Install 4 in media filter
*Install 24x24 aux pan 
Install new primary and secondary float switches 
Install new suction line insulation 
Install new drain line insulation 
Flush existing refrigerant lines 
Flush existing drain line 
New thermostat 


3 year labor warranty 
10 year parts warranty 

8900 cash price
Install 3 ton ruud heat pump 15 seer 
Install new condenser 
*Install 36in Miami dade hurricane pad 
Install new suction line insulation 
Install new vertical air handler 
Custom fabrication of supply plenum (reuse materials)
*Install new insulated stand 
*Install 4 in media filter
*Install 24x24 aux pan 
Install new primary and secondary float switches 
Install new suction line insulation 
Install new drain line insulation 
Flush existing refrigerant lines 
Flush existing drain line 
New thermostat 


3 year labor warranty 
10 year parts warranty 

8900 cash price
Ricky O.
Ricky O. Checked in
Install 3 ton ruud heat pump 15 seer Install new condenser *Install 36in Miami dade hurricane pad Install new suction line insulation Install new vertical air handler Custom fabrication of supply plenum (reuse materials) *Install new insulated stand *Install 4 in media filter *Install 24x24 aux pan Install new primary and secondary float switches Install new suction line insulation Install new drain line insulation Flush existing refrigerant lines Flush existing drain line New thermostat 3 year labor warranty 10 year parts warranty 8900 cash price
Palm Harbor, FL 34683
Reason for call:
No cool/water leak/system replacement estimate

Summary:
Completed drain line flushing, cleaned to restore operation to the equipment, sat down with homeowner and provided estimates for replacement. 
Homeowners aware of all his options.
Reason for call:
No cool/water leak/system replacement estimate

Summary:
Completed drain line flushing, cleaned to restore operation to the equipment, sat down with homeowner and provided estimates for replacement. 
Homeowners aware of all his options.
Corbin C.
Corbin C. Checked in
Reason for call: No cool/water leak/system replacement estimate Summary: Completed drain line flushing, cleaned to restore operation to the equipment, sat down with homeowner and provided estimates for replacement. Homeowners aware of all his options.
Palm Harbor, FL 34683
Client states home does not keep temperature throughout the day. 
Upon my inspection, found home is 2000 sq ft and has a 3 ton system with 2 tons worth of duct work on the supply side. 
Supply plenum is completely blown off of the unit and dumping air into the attic. 
We recommend replacing the duct work to properly balance the system for a 3.4-4ton unit in the future. 
After duct work is replaced and properly sized, the unit can be replaced if desired or needed. 
Client would like a quote for both duct work replacement and system replacement. Sending quotes by tonight.
Client states home does not keep temperature throughout the day. 
Upon my inspection, found home is 2000 sq ft and has a 3 ton system with 2 tons worth of duct work on the supply side. 
Supply plenum is completely blown off of the unit and dumping air into the attic. 
We recommend replacing the duct work to properly balance the system for a 3.4-4ton unit in the future. 
After duct work is replaced and properly sized, the unit can be replaced if desired or needed. 
Client would like a quote for both duct work replacement and system replacement. Sending quotes by tonight.
Michael A.
Michael A. Checked in
Client states home does not keep temperature throughout the day. Upon my inspection, found home is 2000 sq ft and has a 3 ton system with 2 tons worth of duct work on the supply side. Supply plenum is completely blown off of the unit and dumping air into the attic. We recommend replacing the duct work to properly balance the system for a 3.4-4ton unit in the future. After duct work is replaced and properly sized, the unit can be replaced if desired or needed. Client would like a quote for both duct work replacement and system replacement. Sending quotes by tonight.
Palm Harbor, FL 34683
ihsan m.
ihsan m. Checked in
Upon arrival, I began by checking the temperature split between the supply and return air on both systems. Both systems measured an 18°F temperature difference, indicating normal system performance. I then inspected the electrical components on both systems and found all equipment operating within manufacturer specifications, with no components over-amping. The refrigerant cycles were also checked and are operating properly. As part of today’s maintenance, I performed a complete drain line treatment on both systems, cleaned both drain pans, cleaned both condenser coils, and completed a full air handler inspection on each system. Both systems are operating properly at this time. If you have any questions or concerns, please don’t hesitate to reach out. Thank you for your business, and have a great day!
Palm Harbor, FL 34684
Client states system is 1 year old and dripping water. 
Found main issue is system has a severely undersized supply duct system causing high static. 
Found secondary auxiliary pan has large holes cut in it and safety float switch is not positioned properly allowing for water to escape the pan and damage the ceiling. 
Air handler interior is soaked. 

Offered to adjust blower speed for low static option and adjust float switch to aid the system with the current undersized duct system but client would like to hold off and look at a duct work replacement quote first. 

Found supply cfm is limited at 1000 cfm and this unit requires 2000 cfm. Current duct system is not strapped up properly and found many connections that are not properly sealed. 

Supply duct system needs to be upsized to bring the system to a 2000 cfm supply system for proper static. 

Providing a quote for supply duct replacement. We replace duct work in the fall/winter time. Job will have to wait until then. 

Client is
Client states system is 1 year old and dripping water. 
Found main issue is system has a severely undersized supply duct system causing high static. 
Found secondary auxiliary pan has large holes cut in it and safety float switch is not positioned properly allowing for water to escape the pan and damage the ceiling. 
Air handler interior is soaked. 

Offered to adjust blower speed for low static option and adjust float switch to aid the system with the current undersized duct system but client would like to hold off and look at a duct work replacement quote first. 

Found supply cfm is limited at 1000 cfm and this unit requires 2000 cfm. Current duct system is not strapped up properly and found many connections that are not properly sealed. 

Supply duct system needs to be upsized to bring the system to a 2000 cfm supply system for proper static. 

Providing a quote for supply duct replacement. We replace duct work in the fall/winter time. Job will have to wait until then. 

Client is
Michael A.
Michael A. Checked in
Client states system is 1 year old and dripping water. Found main issue is system has a severely undersized supply duct system causing high static. Found secondary auxiliary pan has large holes cut in it and safety float switch is not positioned properly allowing for water to escape the pan and damage the ceiling. Air handler interior is soaked. Offered to adjust blower speed for low static option and adjust float switch to aid the system with the current undersized duct system but client would like to hold off and look at a duct work replacement quote first. Found supply cfm is limited at 1000 cfm and this unit requires 2000 cfm. Current duct system is not strapped up properly and found many connections that are not properly sealed. Supply duct system needs to be upsized to bring the system to a 2000 cfm supply system for proper static. Providing a quote for supply duct replacement. We replace duct work in the fall/winter time. Job will have to wait until then. Client is
Palm Harbor, FL 34685
Ricky O.
Ricky O. Checked in
Found system Not cooling due to bad stat. Replaced stat unit is 2024 just installed. No further issues
Palm Harbor, FL 34683
Corbin C.
Corbin C. Checked in
Reason for call: No cool on mini split Summary: Found leaking flare fitting at condenser. To properly repair equipment redo both flares at condenser. Pulll vacuum to 500 microns Properly charge with 2.7 pounds of 410 Homeowner wanted to reach out to home warranty. Did not proceed with repair.
Palm Harbor, FL 34684
Reason for call:
Ductwork quote turned into diagnostic

2 1/2 ton ox box installed two weeks ago

Summary:
Client said previous company recommended enlarging return ductwork. The return ductwork is a 10 inch return and a 14 inch return supplying a 2 1/2 ton unit with 1040 CFM's. 2 1/2 ton units required 850 to 1050 CFM's. The ductwork is adequate. Found a poor temperature split on the unit hooked up gauges to find the equipment was low on refrigerant. Inform the homeowner it could either be low from Install or it could have a refrigerant leak recommended adding 2 pounds of refrigerant to restore proper operation to the equipment. Homeowner said he's gonna call the other company back to see if they can cover the cost.
He does plan to use this in the future
Reason for call:
Ductwork quote turned into diagnostic

2 1/2 ton ox box installed two weeks ago

Summary:
Client said previous company recommended enlarging return ductwork. The return ductwork is a 10 inch return and a 14 inch return supplying a 2 1/2 ton unit with 1040 CFM's. 2 1/2 ton units required 850 to 1050 CFM's. The ductwork is adequate. Found a poor temperature split on the unit hooked up gauges to find the equipment was low on refrigerant. Inform the homeowner it could either be low from Install or it could have a refrigerant leak recommended adding 2 pounds of refrigerant to restore proper operation to the equipment. Homeowner said he's gonna call the other company back to see if they can cover the cost.
He does plan to use this in the future
Corbin C.
Corbin C. Checked in
Reason for call: Ductwork quote turned into diagnostic 2 1/2 ton ox box installed two weeks ago Summary: Client said previous company recommended enlarging return ductwork. The return ductwork is a 10 inch return and a 14 inch return supplying a 2 1/2 ton unit with 1040 CFM's. 2 1/2 ton units required 850 to 1050 CFM's. The ductwork is adequate. Found a poor temperature split on the unit hooked up gauges to find the equipment was low on refrigerant. Inform the homeowner it could either be low from Install or it could have a refrigerant leak recommended adding 2 pounds of refrigerant to restore proper operation to the equipment. Homeowner said he's gonna call the other company back to see if they can cover the cost. He does plan to use this in the future
Palm Harbor, FL 34683
Reason for call:
No cool

Summary:
Found no low-voltage to my condenser. Found nest thermostat dropping Y.  Jumped thermostat so client had temporary cooling.  He wanted to install his own nest. He went to go pick one up tonight and install it left solution for drain salt cleaning and client supplied thermostat install.
Reason for call:
No cool

Summary:
Found no low-voltage to my condenser. Found nest thermostat dropping Y.  Jumped thermostat so client had temporary cooling.  He wanted to install his own nest. He went to go pick one up tonight and install it left solution for drain salt cleaning and client supplied thermostat install.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: Found no low-voltage to my condenser. Found nest thermostat dropping Y. Jumped thermostat so client had temporary cooling. He wanted to install his own nest. He went to go pick one up tonight and install it left solution for drain salt cleaning and client supplied thermostat install.
Palm Harbor, FL 34685
Return repair on 10" damper and motor. 

Completed repair and adjusted all dampers to close at setting 1 all dampers are operating properly now. 

Completed 1st maintenance to find operation of equipment within manufacturing specifications. Confirmed proper temperatures, amp draws. Flushed coils and drain line.
Return repair on 10" damper and motor. 

Completed repair and adjusted all dampers to close at setting 1 all dampers are operating properly now. 

Completed 1st maintenance to find operation of equipment within manufacturing specifications. Confirmed proper temperatures, amp draws. Flushed coils and drain line.
Corbin C.
Corbin C. Checked in
Return repair on 10" damper and motor. Completed repair and adjusted all dampers to close at setting 1 all dampers are operating properly now. Completed 1st maintenance to find operation of equipment within manufacturing specifications. Confirmed proper temperatures, amp draws. Flushed coils and drain line.
Palm Harbor, FL 34685
Palm Harbor, FL - Reason for call:
Duct work not supplying rooms with proper air flow

Summary:
Found zone four damper seized closed no calling for damper to close but damper was closed and not operating properly forced to damper open and set set point to one damper motor and flange estimate was sold for a later date needs to be scheduled with client.
Corbin C.
Corbin C. Checked in
Reason for call: Duct work not supplying rooms with proper air flow Summary: Found zone four damper seized closed no calling for damper to close but damper was closed and not operating properly forced to damper open and set set point to one damper motor and flange estimate was sold for a later date needs to be scheduled with client.
Palm Harbor, FL 34685
Found frog stuck on fan motor preventing unit from cooling compressor removed animal unit is operating properly now.
Found frog stuck on fan motor preventing unit from cooling compressor removed animal unit is operating properly now.
Corbin C.
Corbin C. Checked in
Found frog stuck on fan motor preventing unit from cooling compressor removed animal unit is operating properly now.
Palm Harbor, FL 34683
2.5 Ton 15.2 SEER Heat Pump 2 stage cooling RUUD system 
~ 10 Year parts warranty  
~ 3 year Labor warranty
- Green cash
5% discount 
______
- Installation of Horizontal air handler in attic east side
- New secondary safety pan
- Seal plenums to unit
- 5 kw back up heat element
- New Wifi Thermostat
- New safety float switches
- New insulation on copper
- Strap up drain line for proper pitch
- Replace breakers as needed
- Flush and test existing condensate drain line
______
- Installation of Condenser unit 
- Flush existing refrigerant lines
- Replace breakers as needed
- New 4” hurricane concrete pad
- New Hurricane straps 
- New UV rated insulation on copper
- New filter line dryer
- Refrigerant locking caps
- Vacuum system to 500 microns
- Charge system with refrigerant to proper pressures

- Completed to code
100% satisfaction
2.5 Ton 15.2 SEER Heat Pump 2 stage cooling RUUD system 
~ 10 Year parts warranty  
~ 3 year Labor warranty
- Green cash
5% discount 
______
- Installation of Horizontal air handler in attic east side
- New secondary safety pan
- Seal plenums to unit
- 5 kw back up heat element
- New Wifi Thermostat
- New safety float switches
- New insulation on copper
- Strap up drain line for proper pitch
- Replace breakers as needed
- Flush and test existing condensate drain line
______
- Installation of Condenser unit 
- Flush existing refrigerant lines
- Replace breakers as needed
- New 4” hurricane concrete pad
- New Hurricane straps 
- New UV rated insulation on copper
- New filter line dryer
- Refrigerant locking caps
- Vacuum system to 500 microns
- Charge system with refrigerant to proper pressures

- Completed to code
100% satisfaction
Sean B.
Sean B. Checked in
2.5 Ton 15.2 SEER Heat Pump 2 stage cooling RUUD system ~ 10 Year parts warranty ~ 3 year Labor warranty - Green cash 5% discount ______ - Installation of Horizontal air handler in attic east side - New secondary safety pan - Seal plenums to unit - 5 kw back up heat element - New Wifi Thermostat - New safety float switches - New insulation on copper - Strap up drain line for proper pitch - Replace breakers as needed - Flush and test existing condensate drain line ______ - Installation of Condenser unit - Flush existing refrigerant lines - Replace breakers as needed - New 4” hurricane concrete pad - New Hurricane straps - New UV rated insulation on copper - New filter line dryer - Refrigerant locking caps - Vacuum system to 500 microns - Charge system with refrigerant to proper pressures - Completed to code 100% satisfaction
Palm Harbor, FL 34683
Kitchen ac system:
Found system had a bad capacitor and contactar, replaced components and started system. System has a 10° temperature split and is not working properly. Found system low on refrigerant and heavily dirty condenser coils. Cleaned condenser coils and added 3lbs refrigerant. Let client know the system is doing the best it can however it is not guaranteed to perform well or for much longer. System is cooling at this time with a 16-17° temperature split.

East system: Client says system won’t cool. Looked at system and found system is 30 years old and in bad shape. Replacement quote accepted and system is being installed Monday.
Kitchen ac system:
Found system had a bad capacitor and contactar, replaced components and started system. System has a 10° temperature split and is not working properly. Found system low on refrigerant and heavily dirty condenser coils. Cleaned condenser coils and added 3lbs refrigerant. Let client know the system is doing the best it can however it is not guaranteed to perform well or for much longer. System is cooling at this time with a 16-17° temperature split.

East system: Client says system won’t cool. Looked at system and found system is 30 years old and in bad shape. Replacement quote accepted and system is being installed Monday.
Michael A.
Michael A. Checked in
Kitchen ac system: Found system had a bad capacitor and contactar, replaced components and started system. System has a 10° temperature split and is not working properly. Found system low on refrigerant and heavily dirty condenser coils. Cleaned condenser coils and added 3lbs refrigerant. Let client know the system is doing the best it can however it is not guaranteed to perform well or for much longer. System is cooling at this time with a 16-17° temperature split. East system: Client says system won’t cool. Looked at system and found system is 30 years old and in bad shape. Replacement quote accepted and system is being installed Monday.
Palm Harbor, FL 34683
Client states yesterday around evening they noticed the system wouldn’t come down to 74 and the condenser didn’t seem to come on. Upon arrival today, found system set to 71 and satisfied at 71. Safety float switch is dry. Client hasn’t had anyone look at the system for atleast 1 year. 
Temperature split is 20°. Amp draws are good. Capacitor is within range. Contactar looks good and has .2 ohm resistance. Tested drain line with water and drained out all water. 

Client said they reset breakers last night. I let them know not to reset breakers again if the issue arises so that we may be able to diagnose the issue while it’s happening.
Client states yesterday around evening they noticed the system wouldn’t come down to 74 and the condenser didn’t seem to come on. Upon arrival today, found system set to 71 and satisfied at 71. Safety float switch is dry. Client hasn’t had anyone look at the system for atleast 1 year. 
Temperature split is 20°. Amp draws are good. Capacitor is within range. Contactar looks good and has .2 ohm resistance. Tested drain line with water and drained out all water. 

Client said they reset breakers last night. I let them know not to reset breakers again if the issue arises so that we may be able to diagnose the issue while it’s happening.
Michael A.
Michael A. Checked in
Client states yesterday around evening they noticed the system wouldn’t come down to 74 and the condenser didn’t seem to come on. Upon arrival today, found system set to 71 and satisfied at 71. Safety float switch is dry. Client hasn’t had anyone look at the system for atleast 1 year. Temperature split is 20°. Amp draws are good. Capacitor is within range. Contactar looks good and has .2 ohm resistance. Tested drain line with water and drained out all water. Client said they reset breakers last night. I let them know not to reset breakers again if the issue arises so that we may be able to diagnose the issue while it’s happening.
Palm Harbor, FL 34685
Replace evaporator coil and TXV under parts warranty
Replace 4 foot of both suction in liquid line at air handler
Replace filter drier
2 pounds of refrigerant
Replaced dual capacitor

Repair was completed pressure and temperature proper at this time.
Replace evaporator coil and TXV under parts warranty
Replace 4 foot of both suction in liquid line at air handler
Replace filter drier
2 pounds of refrigerant
Replaced dual capacitor

Repair was completed pressure and temperature proper at this time.
Corbin C.
Corbin C. Checked in
Replace evaporator coil and TXV under parts warranty Replace 4 foot of both suction in liquid line at air handler Replace filter drier 2 pounds of refrigerant Replaced dual capacitor Repair was completed pressure and temperature proper at this time.
Palm Harbor, FL 34684
Living room system down. 
Upon my inspection, found evaporator coils completely frozen up with thick ice. Air handler blower motor is bad. 
Replaced blower motor and tried to thaw out coils. Coils are taking excessively long to thaw out. Let client know to leave system off over night and start up the following day around afternoon. 
Client stated that system has had to have refrigerant added in the past. I explained that system may be low on refrigerant but we cannot confirm when there is ice on the coils. 
Also found the condenser fan motor was wired improperly which is allowing it to run 24/7. Rewired motor and now it only turns on when the system is calling for cooling. 

Client signed up for 3 system Maitenence plan. Will schedule with office soon to check all three systems and check pressures on the living room system.
Living room system down. 
Upon my inspection, found evaporator coils completely frozen up with thick ice. Air handler blower motor is bad. 
Replaced blower motor and tried to thaw out coils. Coils are taking excessively long to thaw out. Let client know to leave system off over night and start up the following day around afternoon. 
Client stated that system has had to have refrigerant added in the past. I explained that system may be low on refrigerant but we cannot confirm when there is ice on the coils. 
Also found the condenser fan motor was wired improperly which is allowing it to run 24/7. Rewired motor and now it only turns on when the system is calling for cooling. 

Client signed up for 3 system Maitenence plan. Will schedule with office soon to check all three systems and check pressures on the living room system.
Michael A.
Michael A. Checked in
Living room system down. Upon my inspection, found evaporator coils completely frozen up with thick ice. Air handler blower motor is bad. Replaced blower motor and tried to thaw out coils. Coils are taking excessively long to thaw out. Let client know to leave system off over night and start up the following day around afternoon. Client stated that system has had to have refrigerant added in the past. I explained that system may be low on refrigerant but we cannot confirm when there is ice on the coils. Also found the condenser fan motor was wired improperly which is allowing it to run 24/7. Rewired motor and now it only turns on when the system is calling for cooling. Client signed up for 3 system Maitenence plan. Will schedule with office soon to check all three systems and check pressures on the living room system.
Palm Harbor, FL 34681
Reason for call:
No cool 

Summary:
On arrival found compressor shorted to ground. Cussing breaker to trip and compressor plugs to melt to the compressor. 
Offered system replacement. 


Solution:
Homeowner are looking for other quotes.
Reason for call:
No cool 

Summary:
On arrival found compressor shorted to ground. Cussing breaker to trip and compressor plugs to melt to the compressor. 
Offered system replacement. 


Solution:
Homeowner are looking for other quotes.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: On arrival found compressor shorted to ground. Cussing breaker to trip and compressor plugs to melt to the compressor. Offered system replacement. Solution: Homeowner are looking for other quotes.
Palm Harbor, FL 34684
Install new 3 ton 15 seer ruud heat pump 
Install new air handler 
Install new uv kit 
Install new condenser 
Install new condenser pad  
New Filter Drier
Install Thermostat (Auto Changeover)
Thermostat Wire Included
Primary Float Safety Switch
UV Rated Outdoor Insulation
Refrigerant Locking Caps
Flush Existing Refrigerant Lines
Flush Drain Line
Vibration Pads
Hurricane Tie Down Straps
Vacuum System
Seal Supply/Return Plenums
Remove Current Equipment
Permitting
10 Year Parts Warranty
3 Year Labor Warranty
100% Satisfaction
100% property protection
Install new 3 ton 15 seer ruud heat pump 
Install new air handler 
Install new uv kit 
Install new condenser 
Install new condenser pad  
New Filter Drier
Install Thermostat (Auto Changeover)
Thermostat Wire Included
Primary Float Safety Switch
UV Rated Outdoor Insulation
Refrigerant Locking Caps
Flush Existing Refrigerant Lines
Flush Drain Line
Vibration Pads
Hurricane Tie Down Straps
Vacuum System
Seal Supply/Return Plenums
Remove Current Equipment
Permitting
10 Year Parts Warranty
3 Year Labor Warranty
100% Satisfaction
100% property protection
Corbin C.
Corbin C. Checked in
Install new 3 ton 15 seer ruud heat pump Install new air handler Install new uv kit Install new condenser Install new condenser pad New Filter Drier Install Thermostat (Auto Changeover) Thermostat Wire Included Primary Float Safety Switch UV Rated Outdoor Insulation Refrigerant Locking Caps Flush Existing Refrigerant Lines Flush Drain Line Vibration Pads Hurricane Tie Down Straps Vacuum System Seal Supply/Return Plenums Remove Current Equipment Permitting 10 Year Parts Warranty 3 Year Labor Warranty 100% Satisfaction 100% property protection
Palm Harbor, FL 34685
Reason for call:
Tune up 

Equipment:
2022 Icp 4 ton 
Vertical in garage 
Condenser on right side of home 

Summary:
Completed tune up to find system low on refrigerant. Flushed drain line. Flushed both coils. Filter were up to date. Found refrigerant leak at lineset, Evap coil, and txv. Spoke with homeowner we decided to replace warranty components and 4 ft of both lines by Ahu. 
Found dual capacitor weak.
Reason for call:
Tune up 

Equipment:
2022 Icp 4 ton 
Vertical in garage 
Condenser on right side of home 

Summary:
Completed tune up to find system low on refrigerant. Flushed drain line. Flushed both coils. Filter were up to date. Found refrigerant leak at lineset, Evap coil, and txv. Spoke with homeowner we decided to replace warranty components and 4 ft of both lines by Ahu. 
Found dual capacitor weak.
Corbin C.
Corbin C. Checked in
Reason for call: Tune up Equipment: 2022 Icp 4 ton Vertical in garage Condenser on right side of home Summary: Completed tune up to find system low on refrigerant. Flushed drain line. Flushed both coils. Filter were up to date. Found refrigerant leak at lineset, Evap coil, and txv. Spoke with homeowner we decided to replace warranty components and 4 ft of both lines by Ahu. Found dual capacitor weak.
Palm Harbor, FL 34684
Reason for call:
No cool

Equipment:
2010 trane 
Vertical on second floor 
Condenser out back 

Summary: 
On arrival found drain line clogged. Cleared drain line continued diagnosis to find operation of equipment within manufacturing specifications. Coils are slightly dirty. Unit is nearing the end of its life. 

Flush and clean drain line and drain pan. Homeowner signed up on membership.
Reason for call:
No cool

Equipment:
2010 trane 
Vertical on second floor 
Condenser out back 

Summary: 
On arrival found drain line clogged. Cleared drain line continued diagnosis to find operation of equipment within manufacturing specifications. Coils are slightly dirty. Unit is nearing the end of its life. 

Flush and clean drain line and drain pan. Homeowner signed up on membership.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Equipment: 2010 trane Vertical on second floor Condenser out back Summary: On arrival found drain line clogged. Cleared drain line continued diagnosis to find operation of equipment within manufacturing specifications. Coils are slightly dirty. Unit is nearing the end of its life. Flush and clean drain line and drain pan. Homeowner signed up on membership.
Palm Harbor, FL 34683
System not cooling due to failed hard start kit and capacitor. Need to replace both

Replaced components operation was restored to equipment unit cooling with a 20 degree split.
System not cooling due to failed hard start kit and capacitor. Need to replace both

Replaced components operation was restored to equipment unit cooling with a 20 degree split.
Corbin C.
Corbin C. Checked in
System not cooling due to failed hard start kit and capacitor. Need to replace both Replaced components operation was restored to equipment unit cooling with a 20 degree split.
Palm Harbor, FL 34684
Replace warranty blower motor one year warranty on repair
Replace warranty blower motor one year warranty on repair
Corbin C.
Corbin C. Checked in
Replace warranty blower motor one year warranty on repair
Palm Harbor, FL 34684
Reason for call:
No cool 

Equipment:
2022 rheem 2 ton 
Horizontal in attic 
Condenser out back 

Summary:
Found drain line clogged homeowner wanted fee waived. Performer drain cleaning to restore operation to equipment. Unit cooling with 20 degree split. Recommended maintenance plan.
Reason for call:
No cool 

Equipment:
2022 rheem 2 ton 
Horizontal in attic 
Condenser out back 

Summary:
Found drain line clogged homeowner wanted fee waived. Performer drain cleaning to restore operation to equipment. Unit cooling with 20 degree split. Recommended maintenance plan.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Equipment: 2022 rheem 2 ton Horizontal in attic Condenser out back Summary: Found drain line clogged homeowner wanted fee waived. Performer drain cleaning to restore operation to equipment. Unit cooling with 20 degree split. Recommended maintenance plan.
Palm Harbor, FL 34684