Instant Quote Shop Filters Call Air Bros Book Service

Belleair Beach, FL

air-bros-team-with-truck

Expert Cooling, Heating and Electrical In Belleair Beach, FL

Air Bros is proud to provide expert cooling, heating, indoor air quality and electrical services in Belleair Beach, FL. With 24 hour availability and licensed and trained technicians on call, you can trust our impeccable work from start to finish.

We invite you to read our reviews below and find out why your neighbors consider us to be their nearby heating and air company and local electrician in Belleair Beach, FL.

Recent Jobs and Reviews in Belleair Beach, FL

Job Locations and Reviews

Full System Tuneup

2014 Comfort Maker

Cleared drain line and drain pan (heavily backed up)

Inspected Indoor Coils 

Inspected Blower Wheel (Bacterial Growth Accumulating)

System Needs Primary Safety Switch 

Checked Temp Splits 

Checked Thermostat Operations 

IAQ Not Operating 

Outdoor Condenser Coils Corroding Due to Salt Water 

Checked Capacitor 

Checked Contactor 

Tightened Down Connections

 Lightly Rinsed Outdoor Coils 

Ductwork Notes 
-supply plenum not sized appropriately and very weak 
-metal to flex duct connections 
-original metal boots 
-flex not sealed and strapped properly 

Homeowner is swelling home and doesn’t want to put a bunch of money into the house. He would like to just replace supply plenum and supply ducts. Explained we would need to replace boots as well.
Full System Tuneup

2014 Comfort Maker

Cleared drain line and drain pan (heavily backed up)

Inspected Indoor Coils 

Inspected Blower Wheel (Bacterial Growth Accumulating)

System Needs Primary Safety Switch 

Checked Temp Splits 

Checked Thermostat Operations 

IAQ Not Operating 

Outdoor Condenser Coils Corroding Due to Salt Water 

Checked Capacitor 

Checked Contactor 

Tightened Down Connections

 Lightly Rinsed Outdoor Coils 

Ductwork Notes 
-supply plenum not sized appropriately and very weak 
-metal to flex duct connections 
-original metal boots 
-flex not sealed and strapped properly 

Homeowner is swelling home and doesn’t want to put a bunch of money into the house. He would like to just replace supply plenum and supply ducts. Explained we would need to replace boots as well.
Nathan A.
Nathan A. Checked in
Full System Tuneup 2014 Comfort Maker Cleared drain line and drain pan (heavily backed up) Inspected Indoor Coils Inspected Blower Wheel (Bacterial Growth Accumulating) System Needs Primary Safety Switch Checked Temp Splits Checked Thermostat Operations IAQ Not Operating Outdoor Condenser Coils Corroding Due to Salt Water Checked Capacitor Checked Contactor Tightened Down Connections Lightly Rinsed Outdoor Coils Ductwork Notes -supply plenum not sized appropriately and very weak -metal to flex duct connections -original metal boots -flex not sealed and strapped properly Homeowner is swelling home and doesn’t want to put a bunch of money into the house. He would like to just replace supply plenum and supply ducts. Explained we would need to replace boots as well.
Belleair Beach, FL 33786
Install light box in place of old exhaust fan 
Install customer provided light 
Remove switches and receptacle and replace with customer provided devices
Install light box in place of old exhaust fan 
Install customer provided light 
Remove switches and receptacle and replace with customer provided devices
Griffin K.
Griffin K. Checked in
Install light box in place of old exhaust fan Install customer provided light Remove switches and receptacle and replace with customer provided devices
Belleair Beach, FL 33786
Griffin K.
Griffin K. Checked in
Diagnose tripping breaker in bar nook. Found wiring in j box where bath light used to be needed to be rewired so lights could operate properly on AFCI breaker
Belleair Beach, FL 33786
Griffin K.
Griffin K. Checked in
Tripped AFCI breaker when vacuum was plugged in turned circuit back on and ran vacuum no trip
Belleair Beach, FL 33786
Cut in new receptacle in closet get power from recep on the other side of the wall
Install new AFCI GFCI breaker on bedroom circuit 
*** while working on closet recep found the bedroom has no connection to ground ( along with other circuits in the home other circuits are on AFCI GFCI breakers so still protected) installing a AFCI GFCI breaker to protect the circuit
Cut in new receptacle in closet get power from recep on the other side of the wall
Install new AFCI GFCI breaker on bedroom circuit 
*** while working on closet recep found the bedroom has no connection to ground ( along with other circuits in the home other circuits are on AFCI GFCI breakers so still protected) installing a AFCI GFCI breaker to protect the circuit
Griffin K.
Griffin K. Checked in
Cut in new receptacle in closet get power from recep on the other side of the wall Install new AFCI GFCI breaker on bedroom circuit *** while working on closet recep found the bedroom has no connection to ground ( along with other circuits in the home other circuits are on AFCI GFCI breakers so still protected) installing a AFCI GFCI breaker to protect the circuit
Belleair Beach, FL 33786
3.5 ton 15 seer Ruud heat pump
10 year parts warranty
3 year labor warranty
-Miami dade pad
-18” aluminum stand
-Hurricane tiedowns
-UV rated armorflex
-Electrical whip
-Place air handler on same stand
-WiFi stat
-Flush drain
-Replace all exposed pipe insulation
-Locking caps
-Vacuum refrigerant lines below 500 microns
3.5 ton 15 seer Ruud heat pump
10 year parts warranty
3 year labor warranty
-Miami dade pad
-18” aluminum stand
-Hurricane tiedowns
-UV rated armorflex
-Electrical whip
-Place air handler on same stand
-WiFi stat
-Flush drain
-Replace all exposed pipe insulation
-Locking caps
-Vacuum refrigerant lines below 500 microns
Kyle K.
Kyle K. Checked in
3.5 ton 15 seer Ruud heat pump 10 year parts warranty 3 year labor warranty -Miami dade pad -18” aluminum stand -Hurricane tiedowns -UV rated armorflex -Electrical whip -Place air handler on same stand -WiFi stat -Flush drain -Replace all exposed pipe insulation -Locking caps -Vacuum refrigerant lines below 500 microns
Belleair Beach, FL 33786
Performed maintenance on 2 systems. Pressures good. Temp split good. Electrical checked good. Rinsed coils. Cleared pans and drains. 
Will submit estimate for issues from inspectors report including sealing plenum and repairing ductwork. Both units cooling at this time.
Performed maintenance on 2 systems. Pressures good. Temp split good. Electrical checked good. Rinsed coils. Cleared pans and drains. 
Will submit estimate for issues from inspectors report including sealing plenum and repairing ductwork. Both units cooling at this time.
Justin G.
Justin G. Checked in
Performed maintenance on 2 systems. Pressures good. Temp split good. Electrical checked good. Rinsed coils. Cleared pans and drains. Will submit estimate for issues from inspectors report including sealing plenum and repairing ductwork. Both units cooling at this time.
Belleair Beach, FL 33786
Michael A.
Michael A. Checked in
Upon my inspection, I found the duct going to the bedroom with a lack of air flow was kinked and bent too far. I readjusted the duct for better flow and improved the air flow significantly. Checked system pressures and noticed it may be slightly over charged with refrigerant but nothing too concerning. Checked amp draws are good. Temp split is a perfect 20°. System is cooling at this time Recommendations: drain line cleaning and treatment.
Belleair Beach, FL 33786
Belleair Beach, FL - Wire is undersized feeding the lighting in the house for the 20 amp breaker
Remove 20 amp breaker feeding the lighting circuit 
Install new 15 amp breaker 
Troubleshot flickering lights
Griffin K.
Griffin K. Checked in
Wire is undersized feeding the lighting in the house for the 20 amp breaker Remove 20 amp breaker feeding the lighting circuit Install new 15 amp breaker Troubleshot flickering lights
Belleair Beach, FL 33786
Belleair Beach, FL - On arrival found unit not cooling due to blown fuse from shorted condenser contactor. Replaced fuse and contactor. Start and test. Cleared drain. Pressures good. Temp split good. Unit is cooling properly at this time.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to blown fuse from shorted condenser contactor. Replaced fuse and contactor. Start and test. Cleared drain. Pressures good. Temp split good. Unit is cooling properly at this time.
Belleair Beach, FL 33786

Contact the Bros You Know Today!

Schedule Service Online
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at 727-217-6148 .

By pressing Submit I agree to receive phone, email, or text messages from Air Bros Air Conditioning & Heating to the provided mobile number and also agree to the Air Bros Air Conditioning & Heating terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next