Instant Quote Shop Filters Call Air Bros Book Service

Seminole, FL

air-bros-team-with-truck

Your Hometown HVAC Experts

Air Bros Air Conditioning & Heating is deeply rooted in the Seminole, FL, community. We're not just your HVAC service provider; we're your neighbors. We understand the importance of reliable and efficient HVAC systems in Florida's climate, and we're dedicated to keeping your Seminole home comfortable year-round. Whether you live in a cozy bungalow near the beaches or a spacious family home in the heart of Seminole, our team is here to provide top-notch service with a personal touch.

Call us at 727-217-6148 or contact us online for help in Seminole, FL.

Comprehensive HVAC Services in Seminole:

We offer a full range of heating and cooling services tailored to the needs of Seminole residents that provide:

  • Year-Round Comfort: From scorching summers to chilly winter nights, we've got your comfort covered. Our expert technicians provide comprehensive AC and heating services, including repair, installation, and maintenance for all makes and models. We'll keep your home at the perfect temperature, no matter the season.
  • Easy Breathing: Enjoy clean, healthy air in your Largo home. Our indoor air quality solutions, including dehumidifiers and UV light air purifiers, help reduce allergens, control humidity, and create a healthier living environment for you and your family.
  • Optimized Airflow: Maximize your comfort and energy efficiency with our professional ductwork services. We'll ensure proper airflow, prevent energy waste, and improve the overall performance of your HVAC system.

Why Choose Air Bros in Seminole?

  • Your Seminole Neighbors: We're not just an HVAC company; we're part of the Seminole community. We understand the local climate and the importance of reliable HVAC systems for your home.
  • Prompt and Dependable Service: When you need us, we'll be there. We offer same-day service for AC emergencies and prioritize quick response times for all your HVAC needs.
  • Expert Technicians: Our team is highly trained and experienced in all aspects of HVAC service, ensuring you receive top-quality workmanship every time.
  • Honest and Transparent Pricing: We believe in upfront pricing with no hidden fees or surprises. You'll always know exactly what to expect.
  • Your Comfort is Our Priority: We're dedicated to ensuring your complete satisfaction with our services and your home comfort.

Contact Air Bros Today!

Whether you need emergency AC repair, a new heating system installation, or any other HVAC service, Air Bros is here to help. Contact us today for a free consultation or to schedule a service appointment. We're proud to be your trusted HVAC partner in Seminole!

Call us at 727-217-6148 or contact us online for help in Seminole, FL.

Recent Jobs and Reviews in Seminole, FL

Job Locations and Reviews

Griffin K.
Griffin K. Checked in
Pull permit and coordinate with duke to disconnect and reconnect power after inspections Label and remove all wiring from existing panel Install new 150 amp main breaker panel Reinstall wires on new breakers in panels Install whole home surge protector per code
Seminole, FL 33772
Scope of work:
- Membership Maitenence agreement
- Install new Capacitor
- Mastic seal supply plenum
- Mastic seal return plenum
- Seal bottom of unit to coffin box
- Remove Blower wheel and clean/sanitize
- Install UV light
- Install p trap on drain line

Extra $100 discount bundle deal
Scope of work:
- Membership Maitenence agreement
- Install new Capacitor
- Mastic seal supply plenum
- Mastic seal return plenum
- Seal bottom of unit to coffin box
- Remove Blower wheel and clean/sanitize
- Install UV light
- Install p trap on drain line

Extra $100 discount bundle deal
Michael A.
Michael A. Checked in
Scope of work: - Membership Maitenence agreement - Install new Capacitor - Mastic seal supply plenum - Mastic seal return plenum - Seal bottom of unit to coffin box - Remove Blower wheel and clean/sanitize - Install UV light - Install p trap on drain line Extra $100 discount bundle deal
Seminole, FL 33772
Performed Maitenence on system. 
- Capacitor is out of factory tolerance 
- Drain line is missing P-trap to condensate pump 
- Supply plenum is not sealed on the back side
- Return plenum is not sealed
- Unit is not sealed to coffin box
- Condensate pump was very dirty and impacted with growth
- Condenser coils were very dirty restricting airflow
- Indoor Blower wheel has growth and debris

- Evaporator coils are clean
- Cleaned condenser coils
- Checked amp draws on compressor and fan motor
-  Cleaned condensate pump
- Cleaned primary drain pan inside unit
- System has a 23° temp split

Quote sent for all repairs/cleanings.
Performed Maitenence on system. 
- Capacitor is out of factory tolerance 
- Drain line is missing P-trap to condensate pump 
- Supply plenum is not sealed on the back side
- Return plenum is not sealed
- Unit is not sealed to coffin box
- Condensate pump was very dirty and impacted with growth
- Condenser coils were very dirty restricting airflow
- Indoor Blower wheel has growth and debris

- Evaporator coils are clean
- Cleaned condenser coils
- Checked amp draws on compressor and fan motor
-  Cleaned condensate pump
- Cleaned primary drain pan inside unit
- System has a 23° temp split

Quote sent for all repairs/cleanings.
Michael A.
Michael A. Checked in
Performed Maitenence on system. - Capacitor is out of factory tolerance - Drain line is missing P-trap to condensate pump - Supply plenum is not sealed on the back side - Return plenum is not sealed - Unit is not sealed to coffin box - Condensate pump was very dirty and impacted with growth - Condenser coils were very dirty restricting airflow - Indoor Blower wheel has growth and debris - Evaporator coils are clean - Cleaned condenser coils - Checked amp draws on compressor and fan motor - Cleaned condensate pump - Cleaned primary drain pan inside unit - System has a 23° temp split Quote sent for all repairs/cleanings.
Seminole, FL 33772
Griffin K.
Griffin K. Checked in
Estimates
Seminole, FL 33772
Seminole, FL - Reason for call: 
No cool system is freezing 

Equipment:
2013 package unit 

Summary: 
On arrival found system low on charge. Confirmed proper air flow and blower operation. Informed homeowner on her options. She decided to charge it up for temporary operation. No warranty on repair. Client has had issue with duct work sweating 

Solution: 
Provided client with mini split solution to replace package unit and duct work. 

Thank for trusting air bros with your hvac needs. Please feel inclined to leave a five star google review if you feel you received a 5 star service.
Thank you, your technicians Ricky and Corbin.
Ricky O.
Ricky O. Checked in
Reason for call: No cool system is freezing Equipment: 2013 package unit Summary: On arrival found system low on charge. Confirmed proper air flow and blower operation. Informed homeowner on her options. She decided to charge it up for temporary operation. No warranty on repair. Client has had issue with duct work sweating Solution: Provided client with mini split solution to replace package unit and duct work. Thank for trusting air bros with your hvac needs. Please feel inclined to leave a five star google review if you feel you received a 5 star service. Thank you, your technicians Ricky and Corbin.
Seminole, FL 33772
Reason for call:
tune up 

Equipment:
Unit 1 
2012 rheem 5 ton heat pump 

Unit 2 
2025 ruud 2 ton heat pump 

Unit 3 
2021 carrier 2 ton heat pump 

Summary:
Completed Maintenance to find operation of equipment within the manufacturing specifications. Flush drain line thoroughly. Minor cleaning on both indoor and outdoor coil. Filters have been maintained properly. Found unit one ruud flat on charge. We topped this unit off at the last visit. Homeowner is interested in replacement and will decide by Monday. 

Solution:
Presented Findings to homeowner and provided and estimate including 15 seer and 18 seer replacement options for 2012 5 ton. Try to reserve Friday 3/6 for install no confirmation yet. 


Thank you for trusting Air Bros with your hvac needs. If you feel you received a 5 star service please feel inclined to leave us a google review. Thank you. 
Your technician Corbin.
Reason for call:
tune up 

Equipment:
Unit 1 
2012 rheem 5 ton heat pump 

Unit 2 
2025 ruud 2 ton heat pump 

Unit 3 
2021 carrier 2 ton heat pump 

Summary:
Completed Maintenance to find operation of equipment within the manufacturing specifications. Flush drain line thoroughly. Minor cleaning on both indoor and outdoor coil. Filters have been maintained properly. Found unit one ruud flat on charge. We topped this unit off at the last visit. Homeowner is interested in replacement and will decide by Monday. 

Solution:
Presented Findings to homeowner and provided and estimate including 15 seer and 18 seer replacement options for 2012 5 ton. Try to reserve Friday 3/6 for install no confirmation yet. 


Thank you for trusting Air Bros with your hvac needs. If you feel you received a 5 star service please feel inclined to leave us a google review. Thank you. 
Your technician Corbin.
Ricky O.
Ricky O. Checked in
Reason for call: tune up Equipment: Unit 1 2012 rheem 5 ton heat pump Unit 2 2025 ruud 2 ton heat pump Unit 3 2021 carrier 2 ton heat pump Summary: Completed Maintenance to find operation of equipment within the manufacturing specifications. Flush drain line thoroughly. Minor cleaning on both indoor and outdoor coil. Filters have been maintained properly. Found unit one ruud flat on charge. We topped this unit off at the last visit. Homeowner is interested in replacement and will decide by Monday. Solution: Presented Findings to homeowner and provided and estimate including 15 seer and 18 seer replacement options for 2012 5 ton. Try to reserve Friday 3/6 for install no confirmation yet. Thank you for trusting Air Bros with your hvac needs. If you feel you received a 5 star service please feel inclined to leave us a google review. Thank you. Your technician Corbin.
Seminole, FL 33776
Scope of work:
- Perform Duct sanitation. 
- Install Air Purification system in supply duct. 
- Vacuum out return plenum and sanitize *Complimentary*
- install New aluminum filter back return grill for easy access to the filter. 
- complimentary mastic sealant over top of supply plenum attatched to the ceiling.
Scope of work:
- Perform Duct sanitation. 
- Install Air Purification system in supply duct. 
- Vacuum out return plenum and sanitize *Complimentary*
- install New aluminum filter back return grill for easy access to the filter. 
- complimentary mastic sealant over top of supply plenum attatched to the ceiling.
Michael A.
Michael A. Checked in
Scope of work: - Perform Duct sanitation. - Install Air Purification system in supply duct. - Vacuum out return plenum and sanitize *Complimentary* - install New aluminum filter back return grill for easy access to the filter. - complimentary mastic sealant over top of supply plenum attatched to the ceiling.
Seminole, FL 33772
Home owner concern about smell when system kicks on. Inspected air handler coils and blower wheel. Both in great condition. New 4” media filter. Found some growth on wiring and insulation. Cleaned insulation and wiring. Added pan tab to help with buildup. 

Cut a small hole in supply plenum. Found growth in plenum. Inspected all ducting. Ducts are in good standing and strapped properly. Ducts are not mastic sealed. Also found 50ft mixing box (duct board) throughout attic. 

Explained that we could replace the supply plenum and add an air scrubber to help with growth/dander. Home owner not interested in new ducts or replacing large mixing box. Explained we can fog/sanitize ducts. 

Would also recommend adding single bulb air purifier to air handler to mitigate growth. 

4T AH
3.5T Condenser
Home owner concern about smell when system kicks on. Inspected air handler coils and blower wheel. Both in great condition. New 4” media filter. Found some growth on wiring and insulation. Cleaned insulation and wiring. Added pan tab to help with buildup. 

Cut a small hole in supply plenum. Found growth in plenum. Inspected all ducting. Ducts are in good standing and strapped properly. Ducts are not mastic sealed. Also found 50ft mixing box (duct board) throughout attic. 

Explained that we could replace the supply plenum and add an air scrubber to help with growth/dander. Home owner not interested in new ducts or replacing large mixing box. Explained we can fog/sanitize ducts. 

Would also recommend adding single bulb air purifier to air handler to mitigate growth. 

4T AH
3.5T Condenser
Nathan A.
Nathan A. Checked in
Home owner concern about smell when system kicks on. Inspected air handler coils and blower wheel. Both in great condition. New 4” media filter. Found some growth on wiring and insulation. Cleaned insulation and wiring. Added pan tab to help with buildup. Cut a small hole in supply plenum. Found growth in plenum. Inspected all ducting. Ducts are in good standing and strapped properly. Ducts are not mastic sealed. Also found 50ft mixing box (duct board) throughout attic. Explained that we could replace the supply plenum and add an air scrubber to help with growth/dander. Home owner not interested in new ducts or replacing large mixing box. Explained we can fog/sanitize ducts. Would also recommend adding single bulb air purifier to air handler to mitigate growth. 4T AH 3.5T Condenser
Seminole, FL 33777
5T Spilt System (Main Home)

Mini Split (Bonus Room)

Verified split system was operating

Mini Split Diagnostic 
-unit is running low on refrigerant indicating leak. Went over options to perform leak search (325$) and identify if we need a part or if we can fix on site. Explained the system takes 2.5lbs of refrigerant (337$).
-potential damage to outdoor compressor if system is not charged properly or leak repaired 

No confirmation on repairs or decision. Left system off so no further damage.
5T Spilt System (Main Home)

Mini Split (Bonus Room)

Verified split system was operating

Mini Split Diagnostic 
-unit is running low on refrigerant indicating leak. Went over options to perform leak search (325$) and identify if we need a part or if we can fix on site. Explained the system takes 2.5lbs of refrigerant (337$).
-potential damage to outdoor compressor if system is not charged properly or leak repaired 

No confirmation on repairs or decision. Left system off so no further damage.
Nathan A.
Nathan A. Checked in
5T Spilt System (Main Home) Mini Split (Bonus Room) Verified split system was operating Mini Split Diagnostic -unit is running low on refrigerant indicating leak. Went over options to perform leak search (325$) and identify if we need a part or if we can fix on site. Explained the system takes 2.5lbs of refrigerant (337$). -potential damage to outdoor compressor if system is not charged properly or leak repaired No confirmation on repairs or decision. Left system off so no further damage.
Seminole, FL 33776
Found bad outdoor TXV causing unit to go out on low pressure. 
Client would not like to repair at this time due to price and age of system. Quote sent for system replacement.
Found bad outdoor TXV causing unit to go out on low pressure. 
Client would not like to repair at this time due to price and age of system. Quote sent for system replacement.
Michael A.
Michael A. Checked in
Found bad outdoor TXV causing unit to go out on low pressure. Client would not like to repair at this time due to price and age of system. Quote sent for system replacement.
Seminole, FL 33772
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.
Verified heating operations. 
Inspected duct work and recommending duct work replacement if the client would like to remove all growth in ducts. Advised client that we can try a duct sanitation but there is no guarantee that it will prevent any future growth.
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.
Verified heating operations. 
Inspected duct work and recommending duct work replacement if the client would like to remove all growth in ducts. Advised client that we can try a duct sanitation but there is no guarantee that it will prevent any future growth.
Michael A.
Michael A. Checked in
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. Verified heating operations. Inspected duct work and recommending duct work replacement if the client would like to remove all growth in ducts. Advised client that we can try a duct sanitation but there is no guarantee that it will prevent any future growth.
Seminole, FL 33772
Griffin K.
Griffin K. Checked in
Install plug in bathroom below light switch Get a neutral to light switch box from light in the ceiling
Seminole, FL 33776
Upon my inspection, found bad condenser ECM fan motor. Replaced motor and fan blade. Fan blade had an issue coming off of the motor shaft so we replaced it. Applied 5% veteran discount. System is cooling with a 17° split at this time.
Upon my inspection, found bad condenser ECM fan motor. Replaced motor and fan blade. Fan blade had an issue coming off of the motor shaft so we replaced it. Applied 5% veteran discount. System is cooling with a 17° split at this time.
Michael A.
Michael A. Checked in
Upon my inspection, found bad condenser ECM fan motor. Replaced motor and fan blade. Fan blade had an issue coming off of the motor shaft so we replaced it. Applied 5% veteran discount. System is cooling with a 17° split at this time.
Seminole, FL 33776
Pump down system 
Remove air handler 
Remove hanging kit 
Install new hanging kit 
Install air handler 
Re pitch drain line/insulate 
Install primary safety float switch 
Extend high voltage 
Mount electrical disconnect 
Seal supply/return plenum 

*further diagnosis will be needed after unit is serviceable 
*waived 95$ diagnostic
Pump down system 
Remove air handler 
Remove hanging kit 
Install new hanging kit 
Install air handler 
Re pitch drain line/insulate 
Install primary safety float switch 
Extend high voltage 
Mount electrical disconnect 
Seal supply/return plenum 

*further diagnosis will be needed after unit is serviceable 
*waived 95$ diagnostic
Kyle K.
Kyle K. Checked in
Pump down system Remove air handler Remove hanging kit Install new hanging kit Install air handler Re pitch drain line/insulate Install primary safety float switch Extend high voltage Mount electrical disconnect Seal supply/return plenum *further diagnosis will be needed after unit is serviceable *waived 95$ diagnostic
Seminole, FL 33772
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is not within factory range. Replaced capacitor. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.
Found a faulty UV system. Installed new uv system. 
Found primary safety switch was not wired in properly. Wired it back to the system complimentary. 
Indoor fan motor is vibrating abnormally and is at risk of failure. 
Compressor amp draw on start up is over amping. Compressor is at risk of failure as well. 
Advised client to start prepare for a new system install.
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is not within factory range. Replaced capacitor. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.
Found a faulty UV system. Installed new uv system. 
Found primary safety switch was not wired in properly. Wired it back to the system complimentary. 
Indoor fan motor is vibrating abnormally and is at risk of failure. 
Compressor amp draw on start up is over amping. Compressor is at risk of failure as well. 
Advised client to start prepare for a new system install.
Michael A.
Michael A. Checked in
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is not within factory range. Replaced capacitor. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. Found a faulty UV system. Installed new uv system. Found primary safety switch was not wired in properly. Wired it back to the system complimentary. Indoor fan motor is vibrating abnormally and is at risk of failure. Compressor amp draw on start up is over amping. Compressor is at risk of failure as well. Advised client to start prepare for a new system install.
Seminole, FL 33772
Justin G.
Justin G. Checked in
Completed maintenance on all AC systems. Replaced filters, replaced belt. Systems operating properly.
Seminole, FL 33772
Furnish and install the following 
Ruud 3 ton 19 seer2 heat pump inverter split system with 5kw heater
Anchor condenser
Hurricane pad
WiFi Ruud thermostat
Aux pan
Safety switches
New 3/4” drain and insulate 
Rotate unit to face garage door
Remove existing equipment 
Connect to existing ducts and electrical 
Seal unit to code
Tax labor and permit included
**Unit eligible for $2000.00 tax credit**
Furnish and install the following 
Ruud 3 ton 19 seer2 heat pump inverter split system with 5kw heater
Anchor condenser
Hurricane pad
WiFi Ruud thermostat
Aux pan
Safety switches
New 3/4” drain and insulate 
Rotate unit to face garage door
Remove existing equipment 
Connect to existing ducts and electrical 
Seal unit to code
Tax labor and permit included
**Unit eligible for $2000.00 tax credit**
Martin W.
Martin W. Checked in
Furnish and install the following Ruud 3 ton 19 seer2 heat pump inverter split system with 5kw heater Anchor condenser Hurricane pad WiFi Ruud thermostat Aux pan Safety switches New 3/4” drain and insulate Rotate unit to face garage door Remove existing equipment Connect to existing ducts and electrical Seal unit to code Tax labor and permit included **Unit eligible for $2000.00 tax credit**
Seminole, FL 33772
Kyle K.
Kyle K. Checked in
Run new condenser 7 wire Run new thermostat 7 wire
Seminole, FL 33776
Upon my inspection, found system has no high voltage power to air handler. Diagnosed bad 60amp breaker. Verified breaker size with 10kw heater kit and installed new breaker. Verified system functions.
Upon my inspection, found system has no high voltage power to air handler. Diagnosed bad 60amp breaker. Verified breaker size with 10kw heater kit and installed new breaker. Verified system functions.
Michael A.
Michael A. Checked in
Upon my inspection, found system has no high voltage power to air handler. Diagnosed bad 60amp breaker. Verified breaker size with 10kw heater kit and installed new breaker. Verified system functions.
Seminole, FL 33772
Upon my inspection, found generator module not allowing high voltage power to condenser unit. By passed module and advised client to call their generator company for repair. Found dirty evaporator coil and a functional but dirty primary drain pan and drain line. Recommending cleanings with a Maitenence plan membership. System is cooling at this time with a 23° temperature split. Capacitor is good. Compressor is over amping at 85 amps on start up with a max rating of 75.
Upon my inspection, found generator module not allowing high voltage power to condenser unit. By passed module and advised client to call their generator company for repair. Found dirty evaporator coil and a functional but dirty primary drain pan and drain line. Recommending cleanings with a Maitenence plan membership. System is cooling at this time with a 23° temperature split. Capacitor is good. Compressor is over amping at 85 amps on start up with a max rating of 75.
Michael A.
Michael A. Checked in
Upon my inspection, found generator module not allowing high voltage power to condenser unit. By passed module and advised client to call their generator company for repair. Found dirty evaporator coil and a functional but dirty primary drain pan and drain line. Recommending cleanings with a Maitenence plan membership. System is cooling at this time with a 23° temperature split. Capacitor is good. Compressor is over amping at 85 amps on start up with a max rating of 75.
Seminole, FL 33777
Justin G.
Justin G. Checked in
Duct inspection performed. Found 2 ducts to be ruined by rodents. Will submit estimate for duct replacement.
Seminole, FL 33776
18 seer invertor system 
Ruud 
10 year parts warranty 
5 year labor warranty
5 % cash discount 
-Humidity control
-High efficiency 
-2,000$ tax credit 
-4” media filter
-Uv light
-Coffin box
-2 surge protectors
-Permit 
-Hurricane pad
-Tiedowns
-Replace all exposed armorflex
-econet stat
-100% satisfaction guarantee
18 seer invertor system 
Ruud 
10 year parts warranty 
5 year labor warranty
5 % cash discount 
-Humidity control
-High efficiency 
-2,000$ tax credit 
-4” media filter
-Uv light
-Coffin box
-2 surge protectors
-Permit 
-Hurricane pad
-Tiedowns
-Replace all exposed armorflex
-econet stat
-100% satisfaction guarantee
Martin W.
Martin W. Checked in
18 seer invertor system Ruud 10 year parts warranty 5 year labor warranty 5 % cash discount -Humidity control -High efficiency -2,000$ tax credit -4” media filter -Uv light -Coffin box -2 surge protectors -Permit -Hurricane pad -Tiedowns -Replace all exposed armorflex -econet stat -100% satisfaction guarantee
Seminole, FL 33776
Home owner states unit is running but not cooling. Condenser located on rooftop. Found failed outdoor capacitor and contactor heavily pitted/rusted. Replaced both components. Verified system was cooling after repair. 

Waived 95$ diagnostic 

Discounted repair from 700$ to 600$
Home owner states unit is running but not cooling. Condenser located on rooftop. Found failed outdoor capacitor and contactor heavily pitted/rusted. Replaced both components. Verified system was cooling after repair. 

Waived 95$ diagnostic 

Discounted repair from 700$ to 600$
Nathan A.
Nathan A. Checked in
Home owner states unit is running but not cooling. Condenser located on rooftop. Found failed outdoor capacitor and contactor heavily pitted/rusted. Replaced both components. Verified system was cooling after repair. Waived 95$ diagnostic Discounted repair from 700$ to 600$
Seminole, FL 33777
On arrival found unit not cooling due to evaporation coil frozen. Thawed unit. Found coil extremely impacted with dirt and debris. No filter on unit. Blower wheel extremely impacted. Condensate pump is dirty and needs proper cleaning. Outdoor thermostat wire exposed and has potential to cause short. Due to age and condition of coil we can only offer new coil for guarantee. Will submit estimates. Unit is cooling to the best of its ability at this time.
On arrival found unit not cooling due to evaporation coil frozen. Thawed unit. Found coil extremely impacted with dirt and debris. No filter on unit. Blower wheel extremely impacted. Condensate pump is dirty and needs proper cleaning. Outdoor thermostat wire exposed and has potential to cause short. Due to age and condition of coil we can only offer new coil for guarantee. Will submit estimates. Unit is cooling to the best of its ability at this time.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to evaporation coil frozen. Thawed unit. Found coil extremely impacted with dirt and debris. No filter on unit. Blower wheel extremely impacted. Condensate pump is dirty and needs proper cleaning. Outdoor thermostat wire exposed and has potential to cause short. Due to age and condition of coil we can only offer new coil for guarantee. Will submit estimates. Unit is cooling to the best of its ability at this time.
Seminole, FL 33772
Upon my inspection, I found the thermostat was not receiving 24v. Checked entire system and found the drain line and primary rain pan was clogged and the safety switch was cutting off power to the thermostat. I also noticed that water was leaking from the primary drain pan and flooding around the unit and the floors of the house. Upon further inspection, the drain system is installed incorrectly and needs to be reconfigured properly. The main issue is the safety switch is at an upwards slope, so when water fills up in the pan, it starts to over flow before the safety switch can break power to the unit.  Quote is sent for guaranteed repair on this issue. 
Capacitor tested good
Amp draw on compressor is good
Amp draw on fan motor is good
Contactar is in good condition
Delta temp is 19° 
System is cooling properly at this time. 

Recommendations:
- install new proper safety switch
- install new drain line configuration at the air handler with proper slope to prevent the unit from flooding
Upon my inspection, I found the thermostat was not receiving 24v. Checked entire system and found the drain line and primary rain pan was clogged and the safety switch was cutting off power to the thermostat. I also noticed that water was leaking from the primary drain pan and flooding around the unit and the floors of the house. Upon further inspection, the drain system is installed incorrectly and needs to be reconfigured properly. The main issue is the safety switch is at an upwards slope, so when water fills up in the pan, it starts to over flow before the safety switch can break power to the unit.  Quote is sent for guaranteed repair on this issue. 
Capacitor tested good
Amp draw on compressor is good
Amp draw on fan motor is good
Contactar is in good condition
Delta temp is 19° 
System is cooling properly at this time. 

Recommendations:
- install new proper safety switch
- install new drain line configuration at the air handler with proper slope to prevent the unit from flooding
Michael A.
Michael A. Checked in
Upon my inspection, I found the thermostat was not receiving 24v. Checked entire system and found the drain line and primary rain pan was clogged and the safety switch was cutting off power to the thermostat. I also noticed that water was leaking from the primary drain pan and flooding around the unit and the floors of the house. Upon further inspection, the drain system is installed incorrectly and needs to be reconfigured properly. The main issue is the safety switch is at an upwards slope, so when water fills up in the pan, it starts to over flow before the safety switch can break power to the unit. Quote is sent for guaranteed repair on this issue. Capacitor tested good Amp draw on compressor is good Amp draw on fan motor is good Contactar is in good condition Delta temp is 19° System is cooling properly at this time. Recommendations: - install new proper safety switch - install new drain line configuration at the air handler with proper slope to prevent the unit from flooding
Seminole, FL 33776

Contact the Bros You Know Today!

Schedule Service Online
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at 727-217-6148 .

By pressing Submit I agree to receive phone, email, or text messages from Air Bros Air Conditioning & Heating to the provided mobile number and also agree to the Air Bros Air Conditioning & Heating terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next