Instant Quote Shop Filters Call Air Bros

St. Petersburg, FL

air-bros-team-with-truck

The Best AC Repair in St. Petersburg, FL — From Technicians Your Neighbors Already Trust

When your AC quits in the middle of a St. Pete summer, you don't want a stranger in an unmarked van. You want a technician your neighbors already know and trust. Air Bros Air Conditioning & Electrical has been fixing air conditioners in St. Petersburg since 2020, but our roots run deeper — founder Ricky Orta grew up learning the trade from his father and has been a licensed HVAC contractor since 2006. That local, hands-on experience is why homeowners from Historic Kenwood to Snell Isle call us the best AC repair company in St. Petersburg.

We're headquartered right here in the Shore Acres neighborhood, so when you call, you're not routed to a call center — you're talking to the same local team that services your street.

Call us at 727-217-6148 or contact us online today for all of your HVAC, indoor air quality and electrical needs.

Meet the technicians who service St. Petersburg

What to expect when we show up

Calling a repair company you've never used before shouldn't feel like a gamble. Here's exactly how an Air Bros service call goes, every time.

You'll get a heads-up before we arrive, then a uniformed technician in a marked Air Bros vehicle shows up in the window we promised. We diagnose the whole system — not just the obvious symptom — then explain what we found and what your options are before any work starts. You approve the price up front, we make the repair, and we don't leave until we've confirmed the system is cooling the way it should.

Every technician is a background-checked, drug-tested Air Bros employee — never a subcontractor — and each one is trained to service every major AC and heat pump brand. It's the kind of consistency you can only get from a local team that answers to its own name.

And if something isn't right? Our 100% satisfaction guarantee means we make it right.

Signs you need AC repair

St. Petersburg's heat and humidity push air conditioners harder than almost anywhere else in the country. Call for AC repair if you notice:

  • Warm air blowing from vents, or the system running constantly without cooling
  • Water pooling around your air handler (a common issue in St. Pete's older homes with attic-run drain lines)
  • Musty odors or visible mold near vents — a sign of a clogged condensate line or dirty coil
  • Rising humidity indoors despite the AC running
  • Short cycling, tripped breakers, or a system that won't turn on at all

Our technicians diagnose the full system on every call — refrigerant charge, temperature split, electrical connections, and drain line — so you get a real fix, not a temporary patch.

Comprehensive HVAC Services in St. Petersburg

We offer a full range of heating and cooling services to keep your St. Petersburg, FL, home comfortable year-round:

  • Air Conditioning: From AC repair and AC installation to routine maintenance, we ensure your cooling system keeps you comfortable during those hot Florida summers. We offer same-day service for AC emergencies, so you never have to suffer in the heat.
  • Heating: Stay warm and cozy in the winter with our comprehensive heating services. We repair and install all types of heating systems, including furnaces and heat pumps, and offer preventative maintenance to keep your system running efficiently.
  • Indoor Air Quality: Improve your indoor air quality with our dehumidifier and UV light installation services. We'll help you control excess humidity and eliminate airborne contaminants, creating a healthier home environment.
  • Ductwork: Ensure optimal airflow and energy efficiency with our ductwork repair and installation services. We can address leaks and damage, and design a system that's perfect for your home.
  • Pool Heater Services: Extend your swim season with our pool heater installation and repair services.
  • Electrical Services: From outlet and switch replacements to ceiling fan installations to whole-house surge protector installations, we have the experts to handle your electrical service needs.

Our experienced technicians are skilled in all aspects of HVAC service and are dedicated to providing top-quality workmanship and customer care.

Why Choose Air Bros?

  • Local Expertise: We understand the unique climate challenges of St. Petersburg.
  • Fast and Reliable Service: We offer same-day service for AC emergencies and prioritize prompt service for all your HVAC needs.
  • Experienced Technicians: Our team is highly trained and experienced in all aspects of HVAC service.
  • Upfront Pricing: We provide transparent pricing with no hidden costs.
  • Customer Satisfaction Guaranteed: Your comfort and satisfaction are our top priorities.

Contact Air Bros Today!

Whether you need emergency AC repair, a new heating system installation, or any other HVAC service, Air Bros is here to help. Contact us today for a free consultation or to schedule a service appointment. We're proud to be your trusted HVAC partner in St. Petersburg!

Call us at 727-217-6148 or contact us online today!

Recent Jobs and Reviews in St. Petersburg, FL

St. Petersburg, FL at a glance

Air Bros Air Conditioning & Electrical has completed 25 jobs in St. Petersburg, FL in December 2025.

The most recent job was on December 26, 2025.

Air Bros Air Conditioning & Electrical has completed 1,919 jobs in St. Petersburg, FL in the last 12 months. The first job there was in December 2024.

Job Locations and Reviews

On arrival found condenser running due to bad compressor. Found unit was flooded. Unit is a 2023 with after market condenser fan motor. Control board for condenser has all safety components by passed to allow unit to run. Due to extent of damage and condition of unit, we recommend full system replacement to have unit with warranty. Will submit proper estimates when supply houses open on Monday. Unit does not cool at this time.
On arrival found condenser running due to bad compressor. Found unit was flooded. Unit is a 2023 with after market condenser fan motor. Control board for condenser has all safety components by passed to allow unit to run. Due to extent of damage and condition of unit, we recommend full system replacement to have unit with warranty. Will submit proper estimates when supply houses open on Monday. Unit does not cool at this time.
Justin G.
Justin G. Checked in
On arrival found condenser running due to bad compressor. Found unit was flooded. Unit is a 2023 with after market condenser fan motor. Control board for condenser has all safety components by passed to allow unit to run. Due to extent of damage and condition of unit, we recommend full system replacement to have unit with warranty. Will submit proper estimates when supply houses open on Monday. Unit does not cool at this time.
St. Petersburg, FL 33703
Justin G.
Justin G. Checked in
Float switch moved causing unit to shut off. Repositioned float switch and unit started. Unit cooling at this time.
St. Petersburg, FL 33703
Justin G.
Justin G. Checked in
On arrival unit working properly. Performed maintenance. Cleared drain and pump. Temp split good. Electrical checked good. Unit cooling properly at this time.
St. Petersburg, FL 33701
Upon my inspection, found clogged drain line and weak fan motor capacitor on the condenser. Cleaned/ treated drain line and primary drain pan. Replaced 10uf capacitor and left the compressor side of the original capacitor on unit as it is still within its tolerance range. Offered Maitenence plan membership to client but they would like to wait at this time. System is cooling with a 18° temperature split at this time. 

Amp draws on compressor and fan motor are good. Safety switches are functional. Changed filter for client. Last filter was installed in April of 2025.
Upon my inspection, found clogged drain line and weak fan motor capacitor on the condenser. Cleaned/ treated drain line and primary drain pan. Replaced 10uf capacitor and left the compressor side of the original capacitor on unit as it is still within its tolerance range. Offered Maitenence plan membership to client but they would like to wait at this time. System is cooling with a 18° temperature split at this time. 

Amp draws on compressor and fan motor are good. Safety switches are functional. Changed filter for client. Last filter was installed in April of 2025.
Michael A.
Michael A. Checked in
Upon my inspection, found clogged drain line and weak fan motor capacitor on the condenser. Cleaned/ treated drain line and primary drain pan. Replaced 10uf capacitor and left the compressor side of the original capacitor on unit as it is still within its tolerance range. Offered Maitenence plan membership to client but they would like to wait at this time. System is cooling with a 18° temperature split at this time. Amp draws on compressor and fan motor are good. Safety switches are functional. Changed filter for client. Last filter was installed in April of 2025.
St. Petersburg, FL 33712
Install low profile condensate pump 2nd floor at unit. 
Run drain line through attic. 
Cut off and leave the existing drain line capped off. 
Wire condensate pump to Air handler Unit high voltage.
Install low profile condensate pump 2nd floor at unit. 
Run drain line through attic. 
Cut off and leave the existing drain line capped off. 
Wire condensate pump to Air handler Unit high voltage.
Martin W.
Martin W. Checked in
Install low profile condensate pump 2nd floor at unit. Run drain line through attic. Cut off and leave the existing drain line capped off. Wire condensate pump to Air handler Unit high voltage.
St. Petersburg, FL 33703
Clogged drain line caused ceiling damage to bottom floor in kitchen/dining room. 

Tested safety switches which are operating properly. Checked pressures and temperature splits. Verified system operations. Cleared drain line and drain pan. 

Wet switch activated after damage occurred. Explained damage could have been worse if switch was not in place.
Clogged drain line caused ceiling damage to bottom floor in kitchen/dining room. 

Tested safety switches which are operating properly. Checked pressures and temperature splits. Verified system operations. Cleared drain line and drain pan. 

Wet switch activated after damage occurred. Explained damage could have been worse if switch was not in place.
Nathan A.
Nathan A. Checked in
Clogged drain line caused ceiling damage to bottom floor in kitchen/dining room. Tested safety switches which are operating properly. Checked pressures and temperature splits. Verified system operations. Cleared drain line and drain pan. Wet switch activated after damage occurred. Explained damage could have been worse if switch was not in place.
St. Petersburg, FL 33710
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to no high voltage at condenser. All breakers have power at panel. Client states electrical work was just performed at property. No wire from panel is connected to outdoor subpanel. Unable to test unit at this time.
St. Petersburg, FL 33708
Removal of equipment . Will return in January to Install new system. NON PERMITTED.
Removal of equipment . Will return in January to Install new system. NON PERMITTED.
Michael A.
Michael A. Checked in
Removal of equipment . Will return in January to Install new system. NON PERMITTED.
St. Petersburg, FL 33703
Performed Maitenence on system. Drain line is severely clogged and unable to clear. Quoted to install condensate pump for new drainage system. Client accepted and scheduling. Cleaned condenser coils. Evaporator coils are dirty but unit is over 10 years old and client would like to wait till new system is needed. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is not within factory range. Replaced capacitor. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. Advised client to leave system off due to drain line not working properly. Client would like to leave system at 78° and is aware that the system cannot drain and may back up with water. There is a risk of flooding if the safety switch fails.
Performed Maitenence on system. Drain line is severely clogged and unable to clear. Quoted to install condensate pump for new drainage system. Client accepted and scheduling. Cleaned condenser coils. Evaporator coils are dirty but unit is over 10 years old and client would like to wait till new system is needed. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is not within factory range. Replaced capacitor. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. Advised client to leave system off due to drain line not working properly. Client would like to leave system at 78° and is aware that the system cannot drain and may back up with water. There is a risk of flooding if the safety switch fails.
Michael A.
Michael A. Checked in
Performed Maitenence on system. Drain line is severely clogged and unable to clear. Quoted to install condensate pump for new drainage system. Client accepted and scheduling. Cleaned condenser coils. Evaporator coils are dirty but unit is over 10 years old and client would like to wait till new system is needed. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is not within factory range. Replaced capacitor. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. Advised client to leave system off due to drain line not working properly. Client would like to leave system at 78° and is aware that the system cannot drain and may back up with water. There is a risk of flooding if the safety switch fails.
St. Petersburg, FL 33703
Scope of work 
-Remove and install new supply trunk line 
-move trunk line to back side of plenum 
-cap end of plenum 
-install ducting to far left behind trusses (keep attic accessible)
-install 2 full duct living room cut ins 
-install mixing box 
-replace master bedroom duct (attached to main trunk)
-strap and seal ducting that’s being replaced 

**leave 2 extra boots to put up at later time**
Scope of work 
-Remove and install new supply trunk line 
-move trunk line to back side of plenum 
-cap end of plenum 
-install ducting to far left behind trusses (keep attic accessible)
-install 2 full duct living room cut ins 
-install mixing box 
-replace master bedroom duct (attached to main trunk)
-strap and seal ducting that’s being replaced 

**leave 2 extra boots to put up at later time**
Kyle K.
Kyle K. Checked in
Scope of work -Remove and install new supply trunk line -move trunk line to back side of plenum -cap end of plenum -install ducting to far left behind trusses (keep attic accessible) -install 2 full duct living room cut ins -install mixing box -replace master bedroom duct (attached to main trunk) -strap and seal ducting that’s being replaced **leave 2 extra boots to put up at later time**
St. Petersburg, FL 33703
Install New Air Handler 
Install Air Handler UV System
Install New Outdoor Condenser 
New Outdoor Electrical Whip
New Filter Drier 
Install Thermostat (Auto Changeover)
Thermostat Wire Included 
Primary Float Safety Switch 
UV Rated Outdoor Insulation 
Refrigerant Locking Caps
Flush Existing Refrigerant Lines
Flush Drain Line
Vibration Pads
Hurricane Tie Down Straps
Vacuum System 
Seal Supply/Return Plenums 
Remove Current Equipment
Crane Operator 
Permitting 
10 Year Parts Warranty
3 Year Labor Warranty 
100% Satisfaction
Install New Air Handler 
Install Air Handler UV System
Install New Outdoor Condenser 
New Outdoor Electrical Whip
New Filter Drier 
Install Thermostat (Auto Changeover)
Thermostat Wire Included 
Primary Float Safety Switch 
UV Rated Outdoor Insulation 
Refrigerant Locking Caps
Flush Existing Refrigerant Lines
Flush Drain Line
Vibration Pads
Hurricane Tie Down Straps
Vacuum System 
Seal Supply/Return Plenums 
Remove Current Equipment
Crane Operator 
Permitting 
10 Year Parts Warranty
3 Year Labor Warranty 
100% Satisfaction
Kyle K.
Kyle K. Checked in
Install New Air Handler Install Air Handler UV System Install New Outdoor Condenser New Outdoor Electrical Whip New Filter Drier Install Thermostat (Auto Changeover) Thermostat Wire Included Primary Float Safety Switch UV Rated Outdoor Insulation Refrigerant Locking Caps Flush Existing Refrigerant Lines Flush Drain Line Vibration Pads Hurricane Tie Down Straps Vacuum System Seal Supply/Return Plenums Remove Current Equipment Crane Operator Permitting 10 Year Parts Warranty 3 Year Labor Warranty 100% Satisfaction
St. Petersburg, FL 33703
Furnish and install the following 
Ruud 2 ton heat pump 19 seer2 split system with 5kw heater
Miami dade pad with 18” aluminum stand
Surge protector for condenser
Anchor condenser
Refrigerant locking caps
Flush existing line set
Clear drain
Vertical pan
Primary and secondary float switches
Media filter 4”
Uv light
Ruud WiFi thermostat
Remove existing equipment 
Connect to existing ducts and electrical 
Seal unit to code
Tax labor and permit included 
**Unit eligible for $2000.00 tax credit**
Offer expires 12/31/2025 for tax credit
Air Handler model # -RH2VY2417STACNJ
Condenser model # -RD18AY24AJVCA
AHRI # -217176040
Includes $500.00 promotional discount
Furnish and install the following 
Ruud 2 ton heat pump 19 seer2 split system with 5kw heater
Miami dade pad with 18” aluminum stand
Surge protector for condenser
Anchor condenser
Refrigerant locking caps
Flush existing line set
Clear drain
Vertical pan
Primary and secondary float switches
Media filter 4”
Uv light
Ruud WiFi thermostat
Remove existing equipment 
Connect to existing ducts and electrical 
Seal unit to code
Tax labor and permit included 
**Unit eligible for $2000.00 tax credit**
Offer expires 12/31/2025 for tax credit
Air Handler model # -RH2VY2417STACNJ
Condenser model # -RD18AY24AJVCA
AHRI # -217176040
Includes $500.00 promotional discount
Martin W.
Martin W. Checked in
Furnish and install the following Ruud 2 ton heat pump 19 seer2 split system with 5kw heater Miami dade pad with 18” aluminum stand Surge protector for condenser Anchor condenser Refrigerant locking caps Flush existing line set Clear drain Vertical pan Primary and secondary float switches Media filter 4” Uv light Ruud WiFi thermostat Remove existing equipment Connect to existing ducts and electrical Seal unit to code Tax labor and permit included **Unit eligible for $2000.00 tax credit** Offer expires 12/31/2025 for tax credit Air Handler model # -RH2VY2417STACNJ Condenser model # -RD18AY24AJVCA AHRI # -217176040 Includes $500.00 promotional discount
St. Petersburg, FL 33705
Justin G.
Justin G. Checked in
On arrival found condenser breaker tripped due to hard start kit exploding in service panel. Reset breakers and unit started. Units cooling.
St. Petersburg, FL 33704
On arrival found unit leaking water due to clogged drain. Cleared pan and drain. Added chemical to help prevent growth. Found coil and blower dirty. Condenser coil impacted as well. Will submit estimate for cleanings. Unit operating in heating and cooling properly.
On arrival found unit leaking water due to clogged drain. Cleared pan and drain. Added chemical to help prevent growth. Found coil and blower dirty. Condenser coil impacted as well. Will submit estimate for cleanings. Unit operating in heating and cooling properly.
Justin G.
Justin G. Checked in
On arrival found unit leaking water due to clogged drain. Cleared pan and drain. Added chemical to help prevent growth. Found coil and blower dirty. Condenser coil impacted as well. Will submit estimate for cleanings. Unit operating in heating and cooling properly.
St. Petersburg, FL 33703
St. Petersburg, FL - Rewire the 240v feed for the old stove into a 120v feed 
Install conduit to protect wire from physical damage 
Install arc fault breaker in panel for code required protection
Griffin K.
Griffin K. Checked in
Rewire the 240v feed for the old stove into a 120v feed Install conduit to protect wire from physical damage Install arc fault breaker in panel for code required protection
St. Petersburg, FL 33713
Justin G.
Justin G. Checked in
On arrival found air handler breaker bad. Replaced breaker. Start and test. Unit operates properly.
St. Petersburg, FL 33708
Griffin K.
Griffin K. Checked in
Replace bad Lutron switch
St. Petersburg, FL 33704
Justin G.
Justin G. Checked in
Reprogrammed thermostat to allow unit to operate in heating and cooling modes properly. Unit is cooling.
St. Petersburg, FL 33703
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.

Investigated high humidity issue. 
Changed air handler variable speed fan motor setting from 400 CFM to 360 CFM. Air handler is a 3 1/2 ton condenser is a 3 ton. Home is 1400 ft.². System pressures indicate that system is slightly undercharged according to factory specs. Spoke with client about maintenance plan and checking pressures and humidity in the next six months.
Inspected duct work. Duct work looks good and sealed. 

Condenser has fault code: 
UNIT BUS FLT 2
CDA COM BUSY
- reset fault codes
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.

Investigated high humidity issue. 
Changed air handler variable speed fan motor setting from 400 CFM to 360 CFM. Air handler is a 3 1/2 ton condenser is a 3 ton. Home is 1400 ft.². System pressures indicate that system is slightly undercharged according to factory specs. Spoke with client about maintenance plan and checking pressures and humidity in the next six months.
Inspected duct work. Duct work looks good and sealed. 

Condenser has fault code: 
UNIT BUS FLT 2
CDA COM BUSY
- reset fault codes
Michael A.
Michael A. Checked in
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. Investigated high humidity issue. Changed air handler variable speed fan motor setting from 400 CFM to 360 CFM. Air handler is a 3 1/2 ton condenser is a 3 ton. Home is 1400 ft.². System pressures indicate that system is slightly undercharged according to factory specs. Spoke with client about maintenance plan and checking pressures and humidity in the next six months. Inspected duct work. Duct work looks good and sealed. Condenser has fault code: UNIT BUS FLT 2 CDA COM BUSY - reset fault codes
St. Petersburg, FL 33713
Remove receptacle beside switch in kitchen run a new line from an existing receptacle 
Remove single gang switch box and install a 2 gang cut in box 
Had to rework junction box in the attic that was drywalled over to it a safe connection
Remove receptacle beside switch in kitchen run a new line from an existing receptacle 
Remove single gang switch box and install a 2 gang cut in box 
Had to rework junction box in the attic that was drywalled over to it a safe connection
Griffin K.
Griffin K. Checked in
Remove receptacle beside switch in kitchen run a new line from an existing receptacle Remove single gang switch box and install a 2 gang cut in box Had to rework junction box in the attic that was drywalled over to it a safe connection
St. Petersburg, FL 33702
Performed Maitenence on all 4 systems. 
- Cleaned condenser coils. 
- Cleaned and Treated drain lines/Primary drain pans. 
- Checked capacitors. 
- Checked amp draws on compressors. 
- Checked amp draws on fan motors. 
- Inspected all wiring connections. 
- Checked temp split in Cooling and in Heating. 
- Inspected Evaporator coils for cleanliness. 
- Tested safety float switch. 

Unit 1:
AHU- Evaporator coils are dirty and require cleaning. Performed in place cleaning. 
CU- Bad capacitor. Replaced capacitor. 

Unit 2: No current issues. 

Unit 3: 
AHU- Evaporator coils are dirty and require cleaning. Performed in place cleaning. 
CU- Bad capacitor. Replaced capacitor. 

Unit 4: Currently Vacant.  No filter installed. 
CU- Bad capacitor. Client would like to try and wait till next Maitenence to replace. Advised client that the capacitor may completely fail at any time since it is out of its tolerance range.
Performed Maitenence on all 4 systems. 
- Cleaned condenser coils. 
- Cleaned and Treated drain lines/Primary drain pans. 
- Checked capacitors. 
- Checked amp draws on compressors. 
- Checked amp draws on fan motors. 
- Inspected all wiring connections. 
- Checked temp split in Cooling and in Heating. 
- Inspected Evaporator coils for cleanliness. 
- Tested safety float switch. 

Unit 1:
AHU- Evaporator coils are dirty and require cleaning. Performed in place cleaning. 
CU- Bad capacitor. Replaced capacitor. 

Unit 2: No current issues. 

Unit 3: 
AHU- Evaporator coils are dirty and require cleaning. Performed in place cleaning. 
CU- Bad capacitor. Replaced capacitor. 

Unit 4: Currently Vacant.  No filter installed. 
CU- Bad capacitor. Client would like to try and wait till next Maitenence to replace. Advised client that the capacitor may completely fail at any time since it is out of its tolerance range.
Michael A.
Michael A. Checked in
Performed Maitenence on all 4 systems. - Cleaned condenser coils. - Cleaned and Treated drain lines/Primary drain pans. - Checked capacitors. - Checked amp draws on compressors. - Checked amp draws on fan motors. - Inspected all wiring connections. - Checked temp split in Cooling and in Heating. - Inspected Evaporator coils for cleanliness. - Tested safety float switch. Unit 1: AHU- Evaporator coils are dirty and require cleaning. Performed in place cleaning. CU- Bad capacitor. Replaced capacitor. Unit 2: No current issues. Unit 3: AHU- Evaporator coils are dirty and require cleaning. Performed in place cleaning. CU- Bad capacitor. Replaced capacitor. Unit 4: Currently Vacant. No filter installed. CU- Bad capacitor. Client would like to try and wait till next Maitenence to replace. Advised client that the capacitor may completely fail at any time since it is out of its tolerance range.
St. Petersburg, FL 33710
Install electrical to to gas tankless water heater 
Install disconnect switch 
Install GFCI breaker
Install electrical to to gas tankless water heater 
Install disconnect switch 
Install GFCI breaker
Griffin K.
Griffin K. Checked in
Install electrical to to gas tankless water heater Install disconnect switch Install GFCI breaker
St. Petersburg, FL 33713
Replace warranty compressor and refrigerant. Start and test. Tax and labor included.
Replace warranty compressor and refrigerant. Start and test. Tax and labor included.
Justin G.
Justin G. Checked in
Replace warranty compressor and refrigerant. Start and test. Tax and labor included.
St. Petersburg, FL 33703
Justin G.
Justin G. Checked in
Replace condenser fan motor. Pull and clean blower wheel. Sanitize cabinet. Perform maintenance on 1 system. Unit operating properly at this time.
St. Petersburg, FL 33702
Upon my inspection, found main system contactor inside air handler is fried along with the Line side high voltage wire. Opened up service disconnect and heard arcing noise from high voltage wires. Could not remove service disconnect plug. Recommending replacement of contactor and service disconnect box. At the condenser found bad capacitor. Recommending to replace capacitor. System required a drain cleaning and treatment due to visible water in the safety float, which reservoir. Performed on necessary repairs and system is cooling at this time with a 20° temperature split.

Main system ductwork has many holes, not strapped up, and not properly sealed. The supply Plenum off of the unit is damaged and has lost its structural integrity. Recommended that the client replaces the ductwork in the near future.
Upon my inspection, found main system contactor inside air handler is fried along with the Line side high voltage wire. Opened up service disconnect and heard arcing noise from high voltage wires. Could not remove service disconnect plug. Recommending replacement of contactor and service disconnect box. At the condenser found bad capacitor. Recommending to replace capacitor. System required a drain cleaning and treatment due to visible water in the safety float, which reservoir. Performed on necessary repairs and system is cooling at this time with a 20° temperature split.

Main system ductwork has many holes, not strapped up, and not properly sealed. The supply Plenum off of the unit is damaged and has lost its structural integrity. Recommended that the client replaces the ductwork in the near future.
Michael A.
Michael A. Checked in
Upon my inspection, found main system contactor inside air handler is fried along with the Line side high voltage wire. Opened up service disconnect and heard arcing noise from high voltage wires. Could not remove service disconnect plug. Recommending replacement of contactor and service disconnect box. At the condenser found bad capacitor. Recommending to replace capacitor. System required a drain cleaning and treatment due to visible water in the safety float, which reservoir. Performed on necessary repairs and system is cooling at this time with a 20° temperature split. Main system ductwork has many holes, not strapped up, and not properly sealed. The supply Plenum off of the unit is damaged and has lost its structural integrity. Recommended that the client replaces the ductwork in the near future.
St. Petersburg, FL 33714
How do I know if my AC needs repair or full replacement?

Our technicians inspect the full system — age, refrigerant type, corrosion, and repair history — and give you an honest recommendation. If a repair makes sense, we'll fix it. If the unit is beyond its useful life, we'll walk you through replacement options with no pressure.

Are your technicians background-checked and licensed?

Yes. Every Air Bros technician is background-checked, factory-trained, and works under our state HVAC license (#CAC1820499) and electrical license (#EC13015085).

What parts of St. Petersburg do you serve?

We serve all of St. Petersburg, including Downtown, Historic Kenwood, Old Northeast, Snell Isle, Crescent Lake, Shore Acres, and Coquina Key, plus Seminole, Largo, Pinellas Park, and the surrounding beach communities.

Do you offer same-day AC repair in St. Petersburg?

Yes. We offer 24/7 emergency AC repair with same-day service throughout St. Petersburg and the surrounding Pinellas County area.

Is Air Bros a local St. Petersburg company, or a franchise?

Air Bros is 100% locally owned and operated, headquartered in the Shore Acres neighborhood of St. Petersburg. We're not a franchise — every technician is a direct employee, not a subcontractor.

Contact the Bros You Know Today!

Gravity Forms Pagination Must be Steps