Expert Cooling, Heating and Electrical In Clearwater, FL

If you've lived in Clearwater for any length of time, you already know what August feels like when the AC goes out. It's not just uncomfortable — it's the kind of heat that makes an hour feel like a day. We started Air Bros because we grew up here, and we got tired of seeing neighbors get burned by out-of-town companies that didn't understand the difference between a Phoenix summer and a Gulf Coast one.

Clearwater's combination of salt air, nine months of cooling season, and humidity that rarely lets up puts real stress on HVAC equipment. We know this market, we know these homes, and we've seen firsthand what happens when the wrong company installs the wrong system for this climate. We're here to make sure that doesn't happen to you.

Professional AC Repair in Clearwater

When your AC stops working in Clearwater, waiting isn't an option. Temperatures and humidity make an uncomfortable home unbearable within hours, and in the middle of summer, same-day availability matters more than almost anything else.

Air Bros offers same-day Air Conditioning Repair throughout Clearwater and Clearwater Beach for all major brands and models. Our technicians diagnose and repair refrigerant leaks, failed capacitors, frozen evaporator coils, blower motor failures, faulty thermostats, and electrical faults. We arrive with a fully stocked truck so most repairs are completed in a single visit.

Homes near the Gulf are exposed to salt air that corrodes coil fins and electrical contacts faster than inland properties. We inspect for corrosion damage on every repair call and address it before it leads to a larger failure. All pricing is upfront and flat-rate before any work begins — no surprises when the job is done.

The Importance of Proper AC Installation

Choosing the right AC system for a Clearwater home requires more than picking a brand. It requires sizing the unit correctly for Florida's Climate Zone 2 and selecting equipment built to handle high humidity and extended run times. These are decisions that affect how comfortable your home feels and how much you spend on energy bills for the next decade.

An undersized system will run constantly without ever adequately dehumidifying your home. An oversized system will short-cycle, leaving excess moisture in the air and wearing out components prematurely. Either way, the wrong size costs you money every month and shortens the life of your equipment.

Air Bros installs Trane, Carrier, Lennox, and Daikin systems selected specifically for Gulf Coast performance. We recommend variable-speed compressors that manage humidity more effectively than single-stage units and run more quietly and efficiently over the long haul. Every AC System Replacement is permitted through Pinellas County and completed to Florida building code. We also walk you through available financing options and energy efficiency incentives before any contract is signed.

Why AC Maintenance in Clearwater is Paramount

In most of the country, annual AC maintenance is considered sufficient. In Clearwater, twice a year is the standard — and for good reason.

With a cooling season that runs from March through November, your system accumulates wear, dirt, and biological growth at a pace that a single annual visit can't keep up with. Neglected drain lines back up and cause water damage. Dirty coils make your system work harder and drive up your electric bill. Small issues that a technician would catch in April become expensive failures in July. Air Bros recommends a spring tune-up before peak cooling demand and a fall visit before humidity season winds down.

Each HVAC Maintenance visit includes coil cleaning, refrigerant level check, electrical inspection, condensate drain flush, and a corrosion assessment for properties near the water. For vacation rental owners and property managers on Clearwater Beach, we offer preventive maintenance contracts to reduce the risk of mid-booking breakdowns.

For homeowners who want year-round peace of mind, the Air Bros Premium Membership covers both visits for just $18 per month. Members pay no service call fees, get 10% off all repairs, have no overtime charges, and move to the front of the line with priority booking. In a market where a mid-August breakdown means competing with every other Clearwater home for a same-day technician, that priority access alone is worth it. If you're tired of reacting to problems and ready to get ahead of them, the membership is the most cost-effective way to keep your system running through whatever the Gulf Coast throws at it.

Why Clearwater Homeowners Choose Air Bros

We pull permits on every installation through Pinellas County, which protects your home's value and ensures your system is installed to code. Our pricing is upfront and flat-rate — you'll know the full cost before we start, with no surprise charges after the job is done.

Emergency service is available around the clock, including weekends and holidays, because AC failures don't wait for business hours. We service hundreds of beach properties annually and know exactly how to protect equipment from salt air corrosion and Florida humidity. When you call Air Bros, you're talking to someone who knows Clearwater — not a call center routing your ticket to whoever is available. If you have questions about our services, visit our HVAC FAQs page or contact us directly.

Clearwater's climate doesn't give your AC a break, and neither do we. Whether you're dealing with an unexpected breakdown, planning a new installation, or just staying ahead of the season, Air Bros is built for exactly this market. We've earned the trust of Clearwater homeowners by showing up on time, pricing honestly, and doing the job right the first time.

If you need AC Repair, AC Installation, or AC Maintenance, you can rely on Air Bros to take care of Clearwater. Call us today at 727-217-6148 to schedule your appointment.

How often should I service my AC in Clearwater, FL?

In Clearwater and throughout Florida, HVAC systems should be serviced twice per year — once in spring before the heavy cooling season, and once in fall. Florida's near-continuous cooling demand and high humidity place significantly more stress on AC systems than in northern states, making semi-annual maintenance essential rather than optional.

Why do AC systems near Clearwater Beach fail faster?

Properties within a few miles of the Gulf are exposed to salt air that accelerates corrosion on condenser coils, copper lines, and electrical contacts. This can reduce equipment lifespan by three to five years compared to inland Clearwater homes. Annual coil cleaning and corrosion-resistant coatings cost far less than early system replacement.

What HVAC brands work best in Clearwater's humid climate?

For Clearwater's high humidity and long cooling seasons, systems with strong dehumidification performance are the priority. Top performers include Trane, Carrier, Lennox, and Daikin — all offering units rated for Florida's Climate Zone 2. Variable-speed compressors are especially effective at controlling indoor humidity in Gulf Coast climates.

Do you service vacation rental properties in Clearwater Beach?

Yes. We work with many vacation rental owners and property managers throughout Clearwater Beach and the barrier islands. We prioritize fast turnaround on rental properties and offer preventive maintenance contracts to reduce mid-booking breakdowns.

Does humidity in Clearwater cause mold problems in AC systems?

Clearwater's year-round humidity creates ideal conditions for mold and biological growth inside air handlers, evaporator coils, and drain pans. Left unchecked, this circulates through your home's air and can cause health issues for residents. Air Bros inspects for mold and biological buildup on every maintenance visit and recommends UV light air purifiers for homes that have had recurring issues.

Is it worth replacing my AC system before hurricane season in Clearwater?

If your system is more than ten years old or has needed repeated repairs, replacing it before hurricane season is worth serious consideration. A storm doesn't just risk physical damage to your outdoor unit — the power surges and outages that follow can push an already-stressed system over the edge. Air Bros can assess your current system and give you an honest recommendation on whether repair or replacement makes more sense heading into June.

Recent Jobs and Reviews in Clearwater, FL

Clearwater, FL at a glance

Air Bros Air Conditioning & Electrical has completed 25 jobs in Clearwater, FL between August 2026 and September 2026.

The most recent job was on September 10, 2026.

Air Bros Air Conditioning & Electrical has completed 176 jobs in Clearwater, FL in the last 12 months. The first job there was in February 2025.

Job Locations and Reviews

Blower pull and clean. 
UV system 2 year warranty. 
Cleaned and sanitized system. 

Found heating kit is corroded and multiple bad connections/loose. 
Quote accepted to replace. Will perform maitnence at same time.
Blower pull and clean. 
UV system 2 year warranty. 
Cleaned and sanitized system. 

Found heating kit is corroded and multiple bad connections/loose. 
Quote accepted to replace. Will perform maitnence at same time.
Michael A.
Michael A. Checked in
Blower pull and clean. UV system 2 year warranty. Cleaned and sanitized system. Found heating kit is corroded and multiple bad connections/loose. Quote accepted to replace. Will perform maitnence at same time.
Clearwater, FL 33756
Replace air handler breakered disconnect with nonfuse pull disconnect.
Replace air handler breakered disconnect with nonfuse pull disconnect.
Griffin K.
Griffin K. Checked in
Replace air handler breakered disconnect with nonfuse pull disconnect.
Clearwater, FL 33761
System has a clogged drain line. Performed drain cleaning on drain line and primary drain pan. Had to use nitrogen. System is cooling at this time with a 20° temperature split. System is draining properly at this time. Waived $95 service fee.
System has a clogged drain line. Performed drain cleaning on drain line and primary drain pan. Had to use nitrogen. System is cooling at this time with a 20° temperature split. System is draining properly at this time. Waived $95 service fee.
Michael A.
Michael A. Checked in
System has a clogged drain line. Performed drain cleaning on drain line and primary drain pan. Had to use nitrogen. System is cooling at this time with a 20° temperature split. System is draining properly at this time. Waived $95 service fee.
Clearwater, FL 33760
On arrival found unit low on refrigerant. Found leak in condenser coil. Made repairs. Pressure test good. Pulled vacuum on system. Weighed in factory charge. Start and test. Pressures good. Temp split good. Unit cooling properly at this time.
On arrival found unit low on refrigerant. Found leak in condenser coil. Made repairs. Pressure test good. Pulled vacuum on system. Weighed in factory charge. Start and test. Pressures good. Temp split good. Unit cooling properly at this time.
Justin G.
Justin G. Checked in
On arrival found unit low on refrigerant. Found leak in condenser coil. Made repairs. Pressure test good. Pulled vacuum on system. Weighed in factory charge. Start and test. Pressures good. Temp split good. Unit cooling properly at this time.
Clearwater, FL 33762
Reason for call:
Water leak

Summary:
Found clogged drain line and minor growth posh homeowner was concerned of growth force. I recommended him to Erik with protegrity restoration. 

Flushed and clean drain line  
Performed full inspection unit is operating with the manufacturing specifications. Homeowner is not interested in membership.
Reason for call:
Water leak

Summary:
Found clogged drain line and minor growth posh homeowner was concerned of growth force. I recommended him to Erik with protegrity restoration. 

Flushed and clean drain line  
Performed full inspection unit is operating with the manufacturing specifications. Homeowner is not interested in membership.
Corbin C.
Corbin C. Checked in
Reason for call: Water leak Summary: Found clogged drain line and minor growth posh homeowner was concerned of growth force. I recommended him to Erik with protegrity restoration. Flushed and clean drain line Performed full inspection unit is operating with the manufacturing specifications. Homeowner is not interested in membership.
Clearwater, FL 33755
Reason for call:
No cool/ water leak 

Summary:
Found unit off on float switch. 
Found clogged drain 
Performed flushes nad clean on drain line and pans.
Added trap to drain line  
Operation was restored to equipment. 
Unit cooling by 20 degrees 
Full inspection of equipment was completed. Unit is in fair condition. 

Solution:
Flush drain open and pans 
Homeowner signed up on maintenance membership
Reason for call:
No cool/ water leak 

Summary:
Found unit off on float switch. 
Found clogged drain 
Performed flushes nad clean on drain line and pans.
Added trap to drain line  
Operation was restored to equipment. 
Unit cooling by 20 degrees 
Full inspection of equipment was completed. Unit is in fair condition. 

Solution:
Flush drain open and pans 
Homeowner signed up on maintenance membership
Corbin C.
Corbin C. Checked in
Reason for call: No cool/ water leak Summary: Found unit off on float switch. Found clogged drain Performed flushes nad clean on drain line and pans. Added trap to drain line Operation was restored to equipment. Unit cooling by 20 degrees Full inspection of equipment was completed. Unit is in fair condition. Solution: Flush drain open and pans Homeowner signed up on maintenance membership
Clearwater, FL 33764
Found bad capacitor. 
System was running extremely hot without outdoor fan motor running and could have caused irreversible damage to the system. 
Evaporator coils are very dirty. Found extra filter in system that hasn’t been removed for a long time. 
Client would like to replace system in 6 months if it makes it that far. 
Provided system replacement quote.
Found bad capacitor. 
System was running extremely hot without outdoor fan motor running and could have caused irreversible damage to the system. 
Evaporator coils are very dirty. Found extra filter in system that hasn’t been removed for a long time. 
Client would like to replace system in 6 months if it makes it that far. 
Provided system replacement quote.
Michael A.
Michael A. Checked in
Found bad capacitor. System was running extremely hot without outdoor fan motor running and could have caused irreversible damage to the system. Evaporator coils are very dirty. Found extra filter in system that hasn’t been removed for a long time. Client would like to replace system in 6 months if it makes it that far. Provided system replacement quote.
Clearwater, FL 33756
Unit is struggling to cool and leaking water due to clogged evap coil and rusted pan. Went over repair vs replace options with client. Sent quote to replace. They have to talk to owner of condo
Unit is struggling to cool and leaking water due to clogged evap coil and rusted pan. Went over repair vs replace options with client. Sent quote to replace. They have to talk to owner of condo
Ricky O.
Ricky O. Checked in
Unit is struggling to cool and leaking water due to clogged evap coil and rusted pan. Went over repair vs replace options with client. Sent quote to replace. They have to talk to owner of condo
Clearwater, FL 33764
Replace warranty TXV indoor
System is cooling with a 20° temperature split at this time. 
Client signed up for Maitenence plan. Will return to perform first maitenence. 
Client would like to move forward with blower pull and clean.
Replace warranty TXV indoor
System is cooling with a 20° temperature split at this time. 
Client signed up for Maitenence plan. Will return to perform first maitenence. 
Client would like to move forward with blower pull and clean.
Michael A.
Michael A. Checked in
Replace warranty TXV indoor System is cooling with a 20° temperature split at this time. Client signed up for Maitenence plan. Will return to perform first maitenence. Client would like to move forward with blower pull and clean.
Clearwater, FL 33756
Found ducts sweating due to them all laying on insulation in attic and not strapped up properly. Unit is undersized and running constantly. Need to put attic fan above air handler as well as it is sweating.
Found ducts sweating due to them all laying on insulation in attic and not strapped up properly. Unit is undersized and running constantly. Need to put attic fan above air handler as well as it is sweating.
Ricky O.
Ricky O. Checked in
Found ducts sweating due to them all laying on insulation in attic and not strapped up properly. Unit is undersized and running constantly. Need to put attic fan above air handler as well as it is sweating.
Clearwater, FL 33755
Upon my inspection, found package unit system not cooling due to indoor blower motor failure. System is not under warranty. Replaced indoor blower motor and started system. System is cooling at this time.
One year warranty on new blower motor
Upon my inspection, found package unit system not cooling due to indoor blower motor failure. System is not under warranty. Replaced indoor blower motor and started system. System is cooling at this time.
One year warranty on new blower motor
Michael A.
Michael A. Checked in
Upon my inspection, found package unit system not cooling due to indoor blower motor failure. System is not under warranty. Replaced indoor blower motor and started system. System is cooling at this time. One year warranty on new blower motor
Clearwater, FL 33764
Found system has a bad indoor TXV. Quote accepted to replace part warranty TXV. Sending quote for cleanings inside air handler and UV protections. 
System is not cooling at this time. 
Blower motor was set to max speed. Adjusted speed for 3.5 ton condenser.
Found system has a bad indoor TXV. Quote accepted to replace part warranty TXV. Sending quote for cleanings inside air handler and UV protections. 
System is not cooling at this time. 
Blower motor was set to max speed. Adjusted speed for 3.5 ton condenser.
Michael A.
Michael A. Checked in
Found system has a bad indoor TXV. Quote accepted to replace part warranty TXV. Sending quote for cleanings inside air handler and UV protections. System is not cooling at this time. Blower motor was set to max speed. Adjusted speed for 3.5 ton condenser.
Clearwater, FL 33756
Reason for call:
No cool 

Summary:
Found drain line clogged and saftey switches engaged. 
Flushed drain lien and pan. 
Restored proper operation to equipment. 
Confirmed proper pressures. 
Confirmed cap reading. 
Confirmed amp draws. 
System is operating within manufacturing specifications. 
Homeowner signed up for maintenance membership.
Reason for call:
No cool 

Summary:
Found drain line clogged and saftey switches engaged. 
Flushed drain lien and pan. 
Restored proper operation to equipment. 
Confirmed proper pressures. 
Confirmed cap reading. 
Confirmed amp draws. 
System is operating within manufacturing specifications. 
Homeowner signed up for maintenance membership.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: Found drain line clogged and saftey switches engaged. Flushed drain lien and pan. Restored proper operation to equipment. Confirmed proper pressures. Confirmed cap reading. Confirmed amp draws. System is operating within manufacturing specifications. Homeowner signed up for maintenance membership.
Clearwater, FL 33755
Reason for call:
No cool 

Summary:
Found failed capacitor
Found pitted contactor
Replaced both components to restore operation to equipment. 
Unit is cooling by 19 degrees

1 year parts and labor warranty on repair only. 

Informed homeowner of age of system
Reason for call:
No cool 

Summary:
Found failed capacitor
Found pitted contactor
Replaced both components to restore operation to equipment. 
Unit is cooling by 19 degrees

1 year parts and labor warranty on repair only. 

Informed homeowner of age of system
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: Found failed capacitor Found pitted contactor Replaced both components to restore operation to equipment. Unit is cooling by 19 degrees 1 year parts and labor warranty on repair only. Informed homeowner of age of system
Clearwater, FL 33755
Reason for call:
No cool 

Summary:
Found a failed capacitor. 
Operation was restored to equipment unit is cooling with 18 degree split. Homeowner is not interested in membership plan at this time. 

Solution:
Replace contactor 
Replace contactor 
1 year part and labor warranty with repair
Reason for call:
No cool 

Summary:
Found a failed capacitor. 
Operation was restored to equipment unit is cooling with 18 degree split. Homeowner is not interested in membership plan at this time. 

Solution:
Replace contactor 
Replace contactor 
1 year part and labor warranty with repair
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: Found a failed capacitor. Operation was restored to equipment unit is cooling with 18 degree split. Homeowner is not interested in membership plan at this time. Solution: Replace contactor Replace contactor 1 year part and labor warranty with repair
Clearwater, FL 33755
(2) Bags 7” Flex
(1) 7” Collar
(1) 7 Splice Collar 
(1) Ceiling Boot 
(1) Ceiling 1 Way Register 

Duct Connection End of Supply Plenum
(2) Bags 7” Flex
(1) 7” Collar
(1) 7 Splice Collar 
(1) Ceiling Boot 
(1) Ceiling 1 Way Register 

Duct Connection End of Supply Plenum
Nathan A.
Nathan A. Checked in
(2) Bags 7” Flex (1) 7” Collar (1) 7 Splice Collar (1) Ceiling Boot (1) Ceiling 1 Way Register Duct Connection End of Supply Plenum
Clearwater, FL 33765
Clearwater, FL - Replace air handler control board. Unit is not under warranty.
Corbin C.
Corbin C. Checked in
Replace air handler control board. Unit is not under warranty.
Clearwater, FL 33756
Home owner states unit has not been keeping up and electric bills high in home 

2012 3.5T RHEEM 

Air Handler Notes 
-no primary safety switch 
-drain line and pan backing up 
-return not sealed properly 
-supply not sealed properly 
-moisture in high voltage to air handler 
-blower wheel accumulating bacterial growth 
-uv system non operable 
-motor capacitor severely rusted 

Condenser Notes
-head pressure high due to coils being impacted 
-outdoor motor nearing max amp draw 
-low voltage exposed 
-suction line insulation lacking 
-14° temp split due to system not being sealed 

Went over all issues with home owner. Went over potential repair cost vs system replacement options. 


Home owner would like to speak with significant other about replacement
Home owner states unit has not been keeping up and electric bills high in home 

2012 3.5T RHEEM 

Air Handler Notes 
-no primary safety switch 
-drain line and pan backing up 
-return not sealed properly 
-supply not sealed properly 
-moisture in high voltage to air handler 
-blower wheel accumulating bacterial growth 
-uv system non operable 
-motor capacitor severely rusted 

Condenser Notes
-head pressure high due to coils being impacted 
-outdoor motor nearing max amp draw 
-low voltage exposed 
-suction line insulation lacking 
-14° temp split due to system not being sealed 

Went over all issues with home owner. Went over potential repair cost vs system replacement options. 


Home owner would like to speak with significant other about replacement
Nathan A.
Nathan A. Checked in
Home owner states unit has not been keeping up and electric bills high in home 2012 3.5T RHEEM Air Handler Notes -no primary safety switch -drain line and pan backing up -return not sealed properly -supply not sealed properly -moisture in high voltage to air handler -blower wheel accumulating bacterial growth -uv system non operable -motor capacitor severely rusted Condenser Notes -head pressure high due to coils being impacted -outdoor motor nearing max amp draw -low voltage exposed -suction line insulation lacking -14° temp split due to system not being sealed Went over all issues with home owner. Went over potential repair cost vs system replacement options. Home owner would like to speak with significant other about replacement
Clearwater, FL 33759
System not cooling due to bad capacitor. Replaced capacitor and started system. 
Found system is cooling with a poor 13° temperature split. 
Checked pressures and found Air handler TXV is faulty. 
Client would like a quote to replace the TXV as well as a Quote to replace the entire system as it is 10 years old and out of warranty. 

Provided quotes for both solutions. 

It should be noted that the duct work existing in the attic is around 50 years old, has degraded insulation, and likely will need to be replaced for efficiency purposes.
System not cooling due to bad capacitor. Replaced capacitor and started system. 
Found system is cooling with a poor 13° temperature split. 
Checked pressures and found Air handler TXV is faulty. 
Client would like a quote to replace the TXV as well as a Quote to replace the entire system as it is 10 years old and out of warranty. 

Provided quotes for both solutions. 

It should be noted that the duct work existing in the attic is around 50 years old, has degraded insulation, and likely will need to be replaced for efficiency purposes.
Michael A.
Michael A. Checked in
System not cooling due to bad capacitor. Replaced capacitor and started system. Found system is cooling with a poor 13° temperature split. Checked pressures and found Air handler TXV is faulty. Client would like a quote to replace the TXV as well as a Quote to replace the entire system as it is 10 years old and out of warranty. Provided quotes for both solutions. It should be noted that the duct work existing in the attic is around 50 years old, has degraded insulation, and likely will need to be replaced for efficiency purposes.
Clearwater, FL 33765
On arrival found main unit not cooling due to main supply duct falling off. Reconnected duct and sealed. Unit has proper temperature split and cooling.
On arrival found main unit not cooling due to main supply duct falling off. Reconnected duct and sealed. Unit has proper temperature split and cooling.
Justin G.
Justin G. Checked in
On arrival found main unit not cooling due to main supply duct falling off. Reconnected duct and sealed. Unit has proper temperature split and cooling.
Clearwater, FL 33767
Reason for call:
No cool

Summary:
Found clogged drain line and unit off on safety switch on arrival
Confirm confirmed proper temperature
Confirm confirmed proper pressures
Confirmed water cooling temperatures
Flushed drain line and cleaned the drain pan. Unit is operational at this point.
Reason for call:
No cool

Summary:
Found clogged drain line and unit off on safety switch on arrival
Confirm confirmed proper temperature
Confirm confirmed proper pressures
Confirmed water cooling temperatures
Flushed drain line and cleaned the drain pan. Unit is operational at this point.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: Found clogged drain line and unit off on safety switch on arrival Confirm confirmed proper temperature Confirm confirmed proper pressures Confirmed water cooling temperatures Flushed drain line and cleaned the drain pan. Unit is operational at this point.
Clearwater, FL 33756
Reason for call:
No cool 

Summary:
On arrival found this unit failed during pm. Ase was serving units when control board failed. They then went into diagnostics where they unwired float switches and change low-voltage wire at condenser. 
When I started diagnosing, I went to the air handler and followed power from the transformer incoming to the board where I had 28 V and both then only 14 V were coming out of the control board. This shows that the control board has failed. We need to replace the control board to continue diagnostics on the system.
Reason for call:
No cool 

Summary:
On arrival found this unit failed during pm. Ase was serving units when control board failed. They then went into diagnostics where they unwired float switches and change low-voltage wire at condenser. 
When I started diagnosing, I went to the air handler and followed power from the transformer incoming to the board where I had 28 V and both then only 14 V were coming out of the control board. This shows that the control board has failed. We need to replace the control board to continue diagnostics on the system.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: On arrival found this unit failed during pm. Ase was serving units when control board failed. They then went into diagnostics where they unwired float switches and change low-voltage wire at condenser. When I started diagnosing, I went to the air handler and followed power from the transformer incoming to the board where I had 28 V and both then only 14 V were coming out of the control board. This shows that the control board has failed. We need to replace the control board to continue diagnostics on the system.
Clearwater, FL 33756
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to tripped float in aux pan. Cleared pan and drain. Cleaned pump and added chemical. Replaced faulty primary float switch. Rinsed condenser coil. Pressures good. Temp split good. Electrical good. The not cooling properly at this time.
Clearwater, FL 33764
Griffin K.
Griffin K. Checked in
Replaced the 2 damaged breaker in the panel and move them lower in the panel *** this is a temporary repair until the panel can be replaced
Clearwater, FL 33756
Reason for call:
Member tune up 

Summary:
Completed maintenance unit is operating well unit had 20 degree split. Flushed drain line and pan. Flushed indoor and outdoor coils. Changed filter. Homeowner needs to order more filters. 20x20x1
Found dual capacitor slightly weak. Found contactor burnt and pitted   Informed homeowners they decided to replace these parts so we don't have any concern of a break down before next maintenance visit. 

Solution: 
Replace capacitor 
Replace contactor 
1 year parts and labor warranty on repair
Reason for call:
Member tune up 

Summary:
Completed maintenance unit is operating well unit had 20 degree split. Flushed drain line and pan. Flushed indoor and outdoor coils. Changed filter. Homeowner needs to order more filters. 20x20x1
Found dual capacitor slightly weak. Found contactor burnt and pitted   Informed homeowners they decided to replace these parts so we don't have any concern of a break down before next maintenance visit. 

Solution: 
Replace capacitor 
Replace contactor 
1 year parts and labor warranty on repair
Corbin C.
Corbin C. Checked in
Reason for call: Member tune up Summary: Completed maintenance unit is operating well unit had 20 degree split. Flushed drain line and pan. Flushed indoor and outdoor coils. Changed filter. Homeowner needs to order more filters. 20x20x1 Found dual capacitor slightly weak. Found contactor burnt and pitted Informed homeowners they decided to replace these parts so we don't have any concern of a break down before next maintenance visit. Solution: Replace capacitor Replace contactor 1 year parts and labor warranty on repair
Clearwater, FL 33760