Reason for call:
No cool 

Equipment:
2020 2.5 ton package unit 

Summary:
Completed diagnosis to find dual cap dead on arrival replace capacitor operation was restore to equipment. Pressure check was good and 19 td. Notice unit has debris build up and homeowner decided to add membership to maintenance equipment.
Reason for call:
No cool 

Equipment:
2020 2.5 ton package unit 

Summary:
Completed diagnosis to find dual cap dead on arrival replace capacitor operation was restore to equipment. Pressure check was good and 19 td. Notice unit has debris build up and homeowner decided to add membership to maintenance equipment.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Equipment: 2020 2.5 ton package unit Summary: Completed diagnosis to find dual cap dead on arrival replace capacitor operation was restore to equipment. Pressure check was good and 19 td. Notice unit has debris build up and homeowner decided to add membership to maintenance equipment.
Clearwater, FL 33759
Reason for call:
No cool 

Equipment:
2020 Icp 2.5 ton heat pump 
Vertical in closet 
Condenser is located on patio 

Summary:
Found system low on charge. Added two pounds of 410 to restore cooling temporarily. And complete leak search. Found refrigerant leak on the capillary tube base of the outdoor metering device on the condenser. See photos and videos for evidence.

Solution: 
Need to contact distributors on Monday to source parts will build quote and send to client at that time. Please be looking for an estimate come Monday morning. I will shoot you a text when estimate is sent out.
Reason for call:
No cool 

Equipment:
2020 Icp 2.5 ton heat pump 
Vertical in closet 
Condenser is located on patio 

Summary:
Found system low on charge. Added two pounds of 410 to restore cooling temporarily. And complete leak search. Found refrigerant leak on the capillary tube base of the outdoor metering device on the condenser. See photos and videos for evidence.

Solution: 
Need to contact distributors on Monday to source parts will build quote and send to client at that time. Please be looking for an estimate come Monday morning. I will shoot you a text when estimate is sent out.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Equipment: 2020 Icp 2.5 ton heat pump Vertical in closet Condenser is located on patio Summary: Found system low on charge. Added two pounds of 410 to restore cooling temporarily. And complete leak search. Found refrigerant leak on the capillary tube base of the outdoor metering device on the condenser. See photos and videos for evidence. Solution: Need to contact distributors on Monday to source parts will build quote and send to client at that time. Please be looking for an estimate come Monday morning. I will shoot you a text when estimate is sent out.
Clearwater, FL 33760
Reason for call:
3 system tune up 

Summary:
Completed tuneup to find the overall operation of equipment within the manufacturing specifications. On train system found drain when it should not have been. Removed trap. Found two weak capacitors on the train system. Found missing primary float switch on the ox box. Found filter to be sized. Mini split is operating very well.

Updated all filtered except for oxbox at unit 
Flushed indoor and outdoor coils
Flush drain line and drain pan
Confirmed pressures and temperatures

Solutions:
Replaced two capacitors on train system
Add primary float switch to ox box 
Repair needs to be scheduled
Reason for call:
3 system tune up 

Summary:
Completed tuneup to find the overall operation of equipment within the manufacturing specifications. On train system found drain when it should not have been. Removed trap. Found two weak capacitors on the train system. Found missing primary float switch on the ox box. Found filter to be sized. Mini split is operating very well.

Updated all filtered except for oxbox at unit 
Flushed indoor and outdoor coils
Flush drain line and drain pan
Confirmed pressures and temperatures

Solutions:
Replaced two capacitors on train system
Add primary float switch to ox box 
Repair needs to be scheduled
Corbin C.
Corbin C. Checked in
Reason for call: 3 system tune up Summary: Completed tuneup to find the overall operation of equipment within the manufacturing specifications. On train system found drain when it should not have been. Removed trap. Found two weak capacitors on the train system. Found missing primary float switch on the ox box. Found filter to be sized. Mini split is operating very well. Updated all filtered except for oxbox at unit Flushed indoor and outdoor coils Flush drain line and drain pan Confirmed pressures and temperatures Solutions: Replaced two capacitors on train system Add primary float switch to ox box Repair needs to be scheduled
Clearwater, FL 33760
Reason for call:
No cool 

Equipment:
2020 rheem 3 ton 
Horizontal in garage 
Condenser out back 

Summary:
On arrival secondary float was tripped unit was off pan was full of water. Found air handler completely frozen. Defrosted coil to find indoor txv to have a major restriction. Unit is under warranty pressures seem accurate. 

Solution:
Repair option to replace indoor txv under parts warranty. Labor charge only. Air bros is covering materials necessary for repair.
Reason for call:
No cool 

Equipment:
2020 rheem 3 ton 
Horizontal in garage 
Condenser out back 

Summary:
On arrival secondary float was tripped unit was off pan was full of water. Found air handler completely frozen. Defrosted coil to find indoor txv to have a major restriction. Unit is under warranty pressures seem accurate. 

Solution:
Repair option to replace indoor txv under parts warranty. Labor charge only. Air bros is covering materials necessary for repair.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Equipment: 2020 rheem 3 ton Horizontal in garage Condenser out back Summary: On arrival secondary float was tripped unit was off pan was full of water. Found air handler completely frozen. Defrosted coil to find indoor txv to have a major restriction. Unit is under warranty pressures seem accurate. Solution: Repair option to replace indoor txv under parts warranty. Labor charge only. Air bros is covering materials necessary for repair.
Clearwater, FL 33765
Client state system is not keeping up with temperature. Found a severely clogged drain line and a trip to float safety switch. Also found a weak capacitor. Replaced the capacitor and performed a drain cleaning and treatment. Client signed up for maintenance plan, and I performed the first Maitenence. With an 18° temperature split good amp draws and clean coils. Cleaned the condenser coils.
Client state system is not keeping up with temperature. Found a severely clogged drain line and a trip to float safety switch. Also found a weak capacitor. Replaced the capacitor and performed a drain cleaning and treatment. Client signed up for maintenance plan, and I performed the first Maitenence. With an 18° temperature split good amp draws and clean coils. Cleaned the condenser coils.
Michael A.
Michael A. Checked in
Client state system is not keeping up with temperature. Found a severely clogged drain line and a trip to float safety switch. Also found a weak capacitor. Replaced the capacitor and performed a drain cleaning and treatment. Client signed up for maintenance plan, and I performed the first Maitenence. With an 18° temperature split good amp draws and clean coils. Cleaned the condenser coils.
Clearwater, FL 33764
Michael A.
Michael A. Checked in
Client states thermostat of losing power. Upon my inspection found the condensate pump and drain line completely clogged up. Checked temperature split is 20°. Performed a drain cleaning and treatment on the drain line, primary drain pan, and condensate pump. System is now cooling. Recommended a maintenance plan, but Client would like to pass at this time. Client states that evaporator coil was just replaced recently due to a refrigerant leak. Upon arrival, I noticed that the filter door to the unit was off and on the floor as well as there were no filters in any of the ceiling return grills. Highly recommend recommended getting new filters install installed as soon as possible.
Clearwater, FL 33761
Upon my inspection, found the secondary safety switch in the emergency pan was tripped with water. System does not have a primary safety float switch. Performed a drain cleaning on system. Added a primary safety float switch. Checked pressures and found system slightly low on refrigerant. Added 1 pound of refrigerant. As part of first Maintenence, cleaned condenser coils. System was cooling with a 16° temperature split. It is now cooling with a 18° temperature split. Tested drain line with 1 gallon of water. System is cooling and drain draining as best as it can at this time.

Tested capacitor is within tolerance limits. Checked amp draw on compressor. Checked amp draw on condenser fan motor and found the fan motor is over amping.
Upon my inspection, found the secondary safety switch in the emergency pan was tripped with water. System does not have a primary safety float switch. Performed a drain cleaning on system. Added a primary safety float switch. Checked pressures and found system slightly low on refrigerant. Added 1 pound of refrigerant. As part of first Maintenence, cleaned condenser coils. System was cooling with a 16° temperature split. It is now cooling with a 18° temperature split. Tested drain line with 1 gallon of water. System is cooling and drain draining as best as it can at this time.

Tested capacitor is within tolerance limits. Checked amp draw on compressor. Checked amp draw on condenser fan motor and found the fan motor is over amping.
Michael A.
Michael A. Checked in
Upon my inspection, found the secondary safety switch in the emergency pan was tripped with water. System does not have a primary safety float switch. Performed a drain cleaning on system. Added a primary safety float switch. Checked pressures and found system slightly low on refrigerant. Added 1 pound of refrigerant. As part of first Maintenence, cleaned condenser coils. System was cooling with a 16° temperature split. It is now cooling with a 18° temperature split. Tested drain line with 1 gallon of water. System is cooling and drain draining as best as it can at this time. Tested capacitor is within tolerance limits. Checked amp draw on compressor. Checked amp draw on condenser fan motor and found the fan motor is over amping.
Clearwater, FL 33756
Justin G.
Justin G. Checked in
On arrival found all unit not cooling due to low on refrigerant. Added back to factory specs. Unit is cooling. No error codes or electrical issues at this time. Made client aware that if issue happens again then a leak search will be needed to be done to locate leak. Unit cooling.
Clearwater, FL 33755
On arrival found unit not cooling due to weak capacitor. Replaced part. Start and test. Cleaned in place evap coil. Cleared drain. Unit cooling at his time.
On arrival found unit not cooling due to weak capacitor. Replaced part. Start and test. Cleaned in place evap coil. Cleared drain. Unit cooling at his time.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to weak capacitor. Replaced part. Start and test. Cleaned in place evap coil. Cleared drain. Unit cooling at his time.
Clearwater, FL 33761
Install Single 9k BTU Head 
Remote/App Operated 
Install Wall Mounting Bracket 
Hurricane Tie Down Straps
Vibration Pads
New Refrigerant Lines
New Communication Wire
Install Hard Pipe PVC Drain
Install Exterior Line Covers
Install Single 9k btu Outdoor Condenser 
Seal Penetration Points 
Pressure Test Systems 
Vacuum Systems 
Charge Systems 
UV Rated Outdoor Insulation 
Refrigerant Locking Caps
Electrical to Panel/Breaker
Outdoor Surge Protection 
New Outdoor Electrical Whip
New Outdoor Electrical Disconnect 
Permitting 
10 Year Parts Warranty 
3 Year Labor Warranty
Install Single 9k BTU Head 
Remote/App Operated 
Install Wall Mounting Bracket 
Hurricane Tie Down Straps
Vibration Pads
New Refrigerant Lines
New Communication Wire
Install Hard Pipe PVC Drain
Install Exterior Line Covers
Install Single 9k btu Outdoor Condenser 
Seal Penetration Points 
Pressure Test Systems 
Vacuum Systems 
Charge Systems 
UV Rated Outdoor Insulation 
Refrigerant Locking Caps
Electrical to Panel/Breaker
Outdoor Surge Protection 
New Outdoor Electrical Whip
New Outdoor Electrical Disconnect 
Permitting 
10 Year Parts Warranty 
3 Year Labor Warranty
Kyle K.
Kyle K. Checked in
Install Single 9k BTU Head Remote/App Operated Install Wall Mounting Bracket Hurricane Tie Down Straps Vibration Pads New Refrigerant Lines New Communication Wire Install Hard Pipe PVC Drain Install Exterior Line Covers Install Single 9k btu Outdoor Condenser Seal Penetration Points Pressure Test Systems Vacuum Systems Charge Systems UV Rated Outdoor Insulation Refrigerant Locking Caps Electrical to Panel/Breaker Outdoor Surge Protection New Outdoor Electrical Whip New Outdoor Electrical Disconnect Permitting 10 Year Parts Warranty 3 Year Labor Warranty
Clearwater, FL 33765
Clearwater, FL - Installation of Anti Microbial duct work. 
New boots and Grills. 
4 cut in returns
New return and supply plenum. 
All strapped up and sealed to code.
100% satusfaction 
Financing available
Martin W.
Martin W. Checked in
Installation of Anti Microbial duct work. New boots and Grills. 4 cut in returns New return and supply plenum. All strapped up and sealed to code. 100% satusfaction Financing available
Clearwater, FL 33764
Scope of work:
- Remove blower housing assembly. 
- Disconnect fan motor from housing
- Clean and sanitize blower assembly. 
- Re install and test

Recommending UV system to prevent this from happening again
Scope of work:
- Remove blower housing assembly. 
- Disconnect fan motor from housing
- Clean and sanitize blower assembly. 
- Re install and test

Recommending UV system to prevent this from happening again
Michael A.
Michael A. Checked in
Scope of work: - Remove blower housing assembly. - Disconnect fan motor from housing - Clean and sanitize blower assembly. - Re install and test Recommending UV system to prevent this from happening again
Clearwater, FL 33764
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Could not access the end of the drain line due to brush and plants being in the way. Cleaned condenser coils. Evaporator coils are clean but very damaged. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Contactar is chattering and at the end of its life span, we recommend replacing. Found low voltage wires exposed to the elements and we recommend making new connections while also sealing the wire in the condenser service panel. Made sure all connections are tight. System is cooling with an 18° temperature split at this time.

Blower wheel is very impacted with debris and growth. Recommending cleaning
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Could not access the end of the drain line due to brush and plants being in the way. Cleaned condenser coils. Evaporator coils are clean but very damaged. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Contactar is chattering and at the end of its life span, we recommend replacing. Found low voltage wires exposed to the elements and we recommend making new connections while also sealing the wire in the condenser service panel. Made sure all connections are tight. System is cooling with an 18° temperature split at this time.

Blower wheel is very impacted with debris and growth. Recommending cleaning
Michael A.
Michael A. Checked in
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Could not access the end of the drain line due to brush and plants being in the way. Cleaned condenser coils. Evaporator coils are clean but very damaged. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Contactar is chattering and at the end of its life span, we recommend replacing. Found low voltage wires exposed to the elements and we recommend making new connections while also sealing the wire in the condenser service panel. Made sure all connections are tight. System is cooling with an 18° temperature split at this time. Blower wheel is very impacted with debris and growth. Recommending cleaning
Clearwater, FL 33760
Upon my insection, client had another company performing is on the system for roughly 2 years. On their last visit, they recommended replacing the disconnect breaker at the unit, performing an evaporator coil cleaning, performing a blower assembly cleaning, installing a UV light, and adding refrigerant.

Upon my inspection, found disconnect not grounded properly and reconnected ground wire. Disconnect is in working condition. 
Unit has a 20° temperature split. Evaporator coils are slightly impacted with debris and the blower wheel assembly is slightly impacted with debris and bacterial growth. We recommend an evaporator coil cleaning, Blower assembly removal and cleaning, as well as a UV air Purifier inside the system to prevent the growth from returning. 

Amp draws are good, capacitor is within factory range, contactar is in good shape. 

Sending quotes for cleanings and Maitenence service agreement

Waived $95 per office request with repair
Upon my insection, client had another company performing is on the system for roughly 2 years. On their last visit, they recommended replacing the disconnect breaker at the unit, performing an evaporator coil cleaning, performing a blower assembly cleaning, installing a UV light, and adding refrigerant.

Upon my inspection, found disconnect not grounded properly and reconnected ground wire. Disconnect is in working condition. 
Unit has a 20° temperature split. Evaporator coils are slightly impacted with debris and the blower wheel assembly is slightly impacted with debris and bacterial growth. We recommend an evaporator coil cleaning, Blower assembly removal and cleaning, as well as a UV air Purifier inside the system to prevent the growth from returning. 

Amp draws are good, capacitor is within factory range, contactar is in good shape. 

Sending quotes for cleanings and Maitenence service agreement

Waived $95 per office request with repair
Michael A.
Michael A. Checked in
Upon my insection, client had another company performing is on the system for roughly 2 years. On their last visit, they recommended replacing the disconnect breaker at the unit, performing an evaporator coil cleaning, performing a blower assembly cleaning, installing a UV light, and adding refrigerant. Upon my inspection, found disconnect not grounded properly and reconnected ground wire. Disconnect is in working condition. Unit has a 20° temperature split. Evaporator coils are slightly impacted with debris and the blower wheel assembly is slightly impacted with debris and bacterial growth. We recommend an evaporator coil cleaning, Blower assembly removal and cleaning, as well as a UV air Purifier inside the system to prevent the growth from returning. Amp draws are good, capacitor is within factory range, contactar is in good shape. Sending quotes for cleanings and Maitenence service agreement Waived $95 per office request with repair
Clearwater, FL 33765
Ricky O.
Ricky O. Checked in
Found unit not cooling due to bad float switch not allowing system to come on. I replaced float switch and verified operation. Client just wants system running as they are moving tomorrow. System is cooling
Clearwater, FL 33763
Clearwater, FL - Installed uv air purification inside air handler #2.
Michael A.
Michael A. Checked in
Installed uv air purification inside air handler #2.
Clearwater, FL 33761
Ruud 3 ton heat pump
15 seer
10 year parts warranty
3 year labor warranty 
*Green cash price*
-Hurricane pad 
-Hurricane tiedowns
-UV rated armorflex
-Screw line cover back to home and silicone gaps
-New hang kit
-Drain pan
-Safeties
-Flush drain
-Keep existing filter system
-Seal to existing plenums 
-100% satisfaction guarantee
Ruud 3 ton heat pump
15 seer
10 year parts warranty
3 year labor warranty 
*Green cash price*
-Hurricane pad 
-Hurricane tiedowns
-UV rated armorflex
-Screw line cover back to home and silicone gaps
-New hang kit
-Drain pan
-Safeties
-Flush drain
-Keep existing filter system
-Seal to existing plenums 
-100% satisfaction guarantee
Martin W.
Martin W. Checked in
Ruud 3 ton heat pump 15 seer 10 year parts warranty 3 year labor warranty *Green cash price* -Hurricane pad -Hurricane tiedowns -UV rated armorflex -Screw line cover back to home and silicone gaps -New hang kit -Drain pan -Safeties -Flush drain -Keep existing filter system -Seal to existing plenums -100% satisfaction guarantee
Clearwater, FL 33755
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.

Condenser coils were very impacted with debris.  Deep cleaned as part of the Maitenence for this time only. If coils get this bad next time we will have to charge extra for cleaning. 

Quote sent over for Maitenence plan.
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.

Condenser coils were very impacted with debris.  Deep cleaned as part of the Maitenence for this time only. If coils get this bad next time we will have to charge extra for cleaning. 

Quote sent over for Maitenence plan.
Michael A.
Michael A. Checked in
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. Condenser coils were very impacted with debris. Deep cleaned as part of the Maitenence for this time only. If coils get this bad next time we will have to charge extra for cleaning. Quote sent over for Maitenence plan.
Clearwater, FL 33760
Found system freezing up due to severely clogged and impacted evaporator coils. System may also be low on refrigerant but we cannot accurately determine without proper air flow. Found lizard burnt on contactar and capacitor near its max tolerance limit. 
System cannot cool properly at this time. Client would like a system replacement estimate. Quote has been sent over.
Found system freezing up due to severely clogged and impacted evaporator coils. System may also be low on refrigerant but we cannot accurately determine without proper air flow. Found lizard burnt on contactar and capacitor near its max tolerance limit. 
System cannot cool properly at this time. Client would like a system replacement estimate. Quote has been sent over.
Michael A.
Michael A. Checked in
Found system freezing up due to severely clogged and impacted evaporator coils. System may also be low on refrigerant but we cannot accurately determine without proper air flow. Found lizard burnt on contactar and capacitor near its max tolerance limit. System cannot cool properly at this time. Client would like a system replacement estimate. Quote has been sent over.
Clearwater, FL 33756
I checked entire system and found no issues. All previous work done looks good. Cap and wiring good. Td 19. Explained to client not to reset breakers if this happens again just call us immediately and we will come out with no service fee
I checked entire system and found no issues. All previous work done looks good. Cap and wiring good. Td 19. Explained to client not to reset breakers if this happens again just call us immediately and we will come out with no service fee
Ricky O.
Ricky O. Checked in
I checked entire system and found no issues. All previous work done looks good. Cap and wiring good. Td 19. Explained to client not to reset breakers if this happens again just call us immediately and we will come out with no service fee
Clearwater, FL 33760
Upon my inspection, found severely clogged drain that was tripping the safety float switch. Also found evaporator coils are severely clogged, condenser coils dirty, and bare wires at the condenser disconnect causing the breaker to trip. 
Performed drain cleaning, removed faulty wires from disconnect, cleaned condenser coils, and performed Maitenence on system for first membership Maitenence. 
Capacitor is within factory range. Compressor amps are good. Fan motor amps were over its max rating due to dirty condenser coils. 

Client is aware of the severity of the evaporator coils and will schedule as soon as he is ready. 
System is cooling at this time with a 19° temp split. 

When we return to clean evaporator coils, we will re route the lineset connections and pvc connection to allow for filters to be installed directly underneath the coils.
Upon my inspection, found severely clogged drain that was tripping the safety float switch. Also found evaporator coils are severely clogged, condenser coils dirty, and bare wires at the condenser disconnect causing the breaker to trip. 
Performed drain cleaning, removed faulty wires from disconnect, cleaned condenser coils, and performed Maitenence on system for first membership Maitenence. 
Capacitor is within factory range. Compressor amps are good. Fan motor amps were over its max rating due to dirty condenser coils. 

Client is aware of the severity of the evaporator coils and will schedule as soon as he is ready. 
System is cooling at this time with a 19° temp split. 

When we return to clean evaporator coils, we will re route the lineset connections and pvc connection to allow for filters to be installed directly underneath the coils.
Michael A.
Michael A. Checked in
Upon my inspection, found severely clogged drain that was tripping the safety float switch. Also found evaporator coils are severely clogged, condenser coils dirty, and bare wires at the condenser disconnect causing the breaker to trip. Performed drain cleaning, removed faulty wires from disconnect, cleaned condenser coils, and performed Maitenence on system for first membership Maitenence. Capacitor is within factory range. Compressor amps are good. Fan motor amps were over its max rating due to dirty condenser coils. Client is aware of the severity of the evaporator coils and will schedule as soon as he is ready. System is cooling at this time with a 19° temp split. When we return to clean evaporator coils, we will re route the lineset connections and pvc connection to allow for filters to be installed directly underneath the coils.
Clearwater, FL 33756
Performed Maitenence on system. System is working as best as it can given its age and condition. High compressor amps on start up. 
Client would like to invest in new system and duct work but needs to figure out finances first. 
System is cooling at this time.
Performed Maitenence on system. System is working as best as it can given its age and condition. High compressor amps on start up. 
Client would like to invest in new system and duct work but needs to figure out finances first. 
System is cooling at this time.
Michael A.
Michael A. Checked in
Performed Maitenence on system. System is working as best as it can given its age and condition. High compressor amps on start up. Client would like to invest in new system and duct work but needs to figure out finances first. System is cooling at this time.
Clearwater, FL 33764
Clearwater, FL - Install customer supplied ceiling fan and run a new line from a receptacle
Griffin K.
Griffin K. Checked in
Install customer supplied ceiling fan and run a new line from a receptacle
Clearwater, FL 33765
Upon my inspection, found indoor 3amp fuse blown. Found short at condenser contactar. Replaced contactar and fuse. Verified system is cooling at this time. System has a 16° temperature split.
Upon my inspection, found indoor 3amp fuse blown. Found short at condenser contactar. Replaced contactar and fuse. Verified system is cooling at this time. System has a 16° temperature split.
Michael A.
Michael A. Checked in
Upon my inspection, found indoor 3amp fuse blown. Found short at condenser contactar. Replaced contactar and fuse. Verified system is cooling at this time. System has a 16° temperature split.
Clearwater, FL 33763
Installed new warranty evap coil. Charged with new refrigerant. New drain connections off of unit. System is cooling with a 20° temperature split and target superheat. Found weak capacitor but client would not like to replace at this time. 
Performed full Maitenence on system. Checked amp draws, inspected wiring, checked capacitor, cleaned condenser coils, cleaned and treated drain line.
Installed new warranty evap coil. Charged with new refrigerant. New drain connections off of unit. System is cooling with a 20° temperature split and target superheat. Found weak capacitor but client would not like to replace at this time. 
Performed full Maitenence on system. Checked amp draws, inspected wiring, checked capacitor, cleaned condenser coils, cleaned and treated drain line.
Michael A.
Michael A. Checked in
Installed new warranty evap coil. Charged with new refrigerant. New drain connections off of unit. System is cooling with a 20° temperature split and target superheat. Found weak capacitor but client would not like to replace at this time. Performed full Maitenence on system. Checked amp draws, inspected wiring, checked capacitor, cleaned condenser coils, cleaned and treated drain line.
Clearwater, FL 33756

Contact the Bros You Know Today!

Schedule Service Online
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at 727-217-6148 .

By pressing Submit I agree to receive phone, email, or text messages from Air Bros Air Conditioning & Heating to the provided mobile number and also agree to the Air Bros Air Conditioning & Heating terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next