Instant Quote Shop Filters Call Air Bros

Clearwater, FL

air-bros-team-with-truck

Expert Cooling, Heating and Electrical In Clearwater, FL

If you've lived in Clearwater for any length of time, you already know what August feels like when the AC goes out. It's not just uncomfortable — it's the kind of heat that makes an hour feel like a day. We started Air Bros because we grew up here, and we got tired of seeing neighbors get burned by out-of-town companies that didn't understand the difference between a Phoenix summer and a Gulf Coast one.

Clearwater's combination of salt air, nine months of cooling season, and humidity that rarely lets up puts real stress on HVAC equipment. We know this market, we know these homes, and we've seen firsthand what happens when the wrong company installs the wrong system for this climate. We're here to make sure that doesn't happen to you.

Professional AC Repair in Clearwater

When your AC stops working in Clearwater, waiting isn't an option. Temperatures and humidity make an uncomfortable home unbearable within hours, and in the middle of summer, same-day availability matters more than almost anything else.

Air Bros offers same-day Air Conditioning Repair throughout Clearwater and Clearwater Beach for all major brands and models. Our technicians diagnose and repair refrigerant leaks, failed capacitors, frozen evaporator coils, blower motor failures, faulty thermostats, and electrical faults. We arrive with a fully stocked truck so most repairs are completed in a single visit.

Homes near the Gulf are exposed to salt air that corrodes coil fins and electrical contacts faster than inland properties. We inspect for corrosion damage on every repair call and address it before it leads to a larger failure. All pricing is upfront and flat-rate before any work begins — no surprises when the job is done.

The Importance of Proper AC Installation

Choosing the right AC system for a Clearwater home requires more than picking a brand. It requires sizing the unit correctly for Florida's Climate Zone 2 and selecting equipment built to handle high humidity and extended run times. These are decisions that affect how comfortable your home feels and how much you spend on energy bills for the next decade.

An undersized system will run constantly without ever adequately dehumidifying your home. An oversized system will short-cycle, leaving excess moisture in the air and wearing out components prematurely. Either way, the wrong size costs you money every month and shortens the life of your equipment.

Air Bros installs Trane, Carrier, Lennox, and Daikin systems selected specifically for Gulf Coast performance. We recommend variable-speed compressors that manage humidity more effectively than single-stage units and run more quietly and efficiently over the long haul. Every AC System Replacement is permitted through Pinellas County and completed to Florida building code. We also walk you through available financing options and energy efficiency incentives before any contract is signed.

Why AC Maintenance in Clearwater is Paramount

In most of the country, annual AC maintenance is considered sufficient. In Clearwater, twice a year is the standard — and for good reason.

With a cooling season that runs from March through November, your system accumulates wear, dirt, and biological growth at a pace that a single annual visit can't keep up with. Neglected drain lines back up and cause water damage. Dirty coils make your system work harder and drive up your electric bill. Small issues that a technician would catch in April become expensive failures in July. Air Bros recommends a spring tune-up before peak cooling demand and a fall visit before humidity season winds down.

Each HVAC Maintenance visit includes coil cleaning, refrigerant level check, electrical inspection, condensate drain flush, and a corrosion assessment for properties near the water. For vacation rental owners and property managers on Clearwater Beach, we offer preventive maintenance contracts to reduce the risk of mid-booking breakdowns.

For homeowners who want year-round peace of mind, the Air Bros Premium Membership covers both visits for just $18 per month. Members pay no service call fees, get 10% off all repairs, have no overtime charges, and move to the front of the line with priority booking. In a market where a mid-August breakdown means competing with every other Clearwater home for a same-day technician, that priority access alone is worth it. If you're tired of reacting to problems and ready to get ahead of them, the membership is the most cost-effective way to keep your system running through whatever the Gulf Coast throws at it.

Why Clearwater Homeowners Choose Air Bros

We pull permits on every installation through Pinellas County, which protects your home's value and ensures your system is installed to code. Our pricing is upfront and flat-rate — you'll know the full cost before we start, with no surprise charges after the job is done.

Emergency service is available around the clock, including weekends and holidays, because AC failures don't wait for business hours. We service hundreds of beach properties annually and know exactly how to protect equipment from salt air corrosion and Florida humidity. When you call Air Bros, you're talking to someone who knows Clearwater — not a call center routing your ticket to whoever is available. If you have questions about our services, visit our HVAC FAQs page or contact us directly.

Clearwater's climate doesn't give your AC a break, and neither do we. Whether you're dealing with an unexpected breakdown, planning a new installation, or just staying ahead of the season, Air Bros is built for exactly this market. We've earned the trust of Clearwater homeowners by showing up on time, pricing honestly, and doing the job right the first time.

If you need AC Repair, AC Installation, or AC Maintenance, you can rely on Air Bros to take care of Clearwater. Call us today at 727-217-6148 to schedule your appointment.

How often should I service my AC in Clearwater, FL?

In Clearwater and throughout Florida, HVAC systems should be serviced twice per year — once in spring before the heavy cooling season, and once in fall. Florida's near-continuous cooling demand and high humidity place significantly more stress on AC systems than in northern states, making semi-annual maintenance essential rather than optional.

Why do AC systems near Clearwater Beach fail faster?

Properties within a few miles of the Gulf are exposed to salt air that accelerates corrosion on condenser coils, copper lines, and electrical contacts. This can reduce equipment lifespan by three to five years compared to inland Clearwater homes. Annual coil cleaning and corrosion-resistant coatings cost far less than early system replacement.

What HVAC brands work best in Clearwater's humid climate?

For Clearwater's high humidity and long cooling seasons, systems with strong dehumidification performance are the priority. Top performers include Trane, Carrier, Lennox, and Daikin — all offering units rated for Florida's Climate Zone 2. Variable-speed compressors are especially effective at controlling indoor humidity in Gulf Coast climates.

Do you service vacation rental properties in Clearwater Beach?

Yes. We work with many vacation rental owners and property managers throughout Clearwater Beach and the barrier islands. We prioritize fast turnaround on rental properties and offer preventive maintenance contracts to reduce mid-booking breakdowns.

Does humidity in Clearwater cause mold problems in AC systems?

Clearwater's year-round humidity creates ideal conditions for mold and biological growth inside air handlers, evaporator coils, and drain pans. Left unchecked, this circulates through your home's air and can cause health issues for residents. Air Bros inspects for mold and biological buildup on every maintenance visit and recommends UV light air purifiers for homes that have had recurring issues.

Is it worth replacing my AC system before hurricane season in Clearwater?

If your system is more than ten years old or has needed repeated repairs, replacing it before hurricane season is worth serious consideration. A storm doesn't just risk physical damage to your outdoor unit — the power surges and outages that follow can push an already-stressed system over the edge. Air Bros can assess your current system and give you an honest recommendation on whether repair or replacement makes more sense heading into June.

Recent Jobs and Reviews in Clearwater, FL

Job Locations and Reviews

Reason for call:
No cool

Summary:
Found clogged drain line and unit off on safety switch on arrival
Confirm confirmed proper temperature
Confirm confirmed proper pressures
Confirmed water cooling temperatures
Flushed drain line and cleaned the drain pan. Unit is operational at this point.
Reason for call:
No cool

Summary:
Found clogged drain line and unit off on safety switch on arrival
Confirm confirmed proper temperature
Confirm confirmed proper pressures
Confirmed water cooling temperatures
Flushed drain line and cleaned the drain pan. Unit is operational at this point.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: Found clogged drain line and unit off on safety switch on arrival Confirm confirmed proper temperature Confirm confirmed proper pressures Confirmed water cooling temperatures Flushed drain line and cleaned the drain pan. Unit is operational at this point.
Clearwater, FL 33756
Reason for call:
No cool 

Summary:
On arrival found this unit failed during pm. Ase was serving units when control board failed. They then went into diagnostics where they unwired float switches and change low-voltage wire at condenser. 
When I started diagnosing, I went to the air handler and followed power from the transformer incoming to the board where I had 28 V and both then only 14 V were coming out of the control board. This shows that the control board has failed. We need to replace the control board to continue diagnostics on the system.
Reason for call:
No cool 

Summary:
On arrival found this unit failed during pm. Ase was serving units when control board failed. They then went into diagnostics where they unwired float switches and change low-voltage wire at condenser. 
When I started diagnosing, I went to the air handler and followed power from the transformer incoming to the board where I had 28 V and both then only 14 V were coming out of the control board. This shows that the control board has failed. We need to replace the control board to continue diagnostics on the system.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: On arrival found this unit failed during pm. Ase was serving units when control board failed. They then went into diagnostics where they unwired float switches and change low-voltage wire at condenser. When I started diagnosing, I went to the air handler and followed power from the transformer incoming to the board where I had 28 V and both then only 14 V were coming out of the control board. This shows that the control board has failed. We need to replace the control board to continue diagnostics on the system.
Clearwater, FL 33756
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to tripped float in aux pan. Cleared pan and drain. Cleaned pump and added chemical. Replaced faulty primary float switch. Rinsed condenser coil. Pressures good. Temp split good. Electrical good. The not cooling properly at this time.
Clearwater, FL 33764
Griffin K.
Griffin K. Checked in
Replaced the 2 damaged breaker in the panel and move them lower in the panel *** this is a temporary repair until the panel can be replaced
Clearwater, FL 33756
Reason for call:
Member tune up 

Summary:
Completed maintenance unit is operating well unit had 20 degree split. Flushed drain line and pan. Flushed indoor and outdoor coils. Changed filter. Homeowner needs to order more filters. 20x20x1
Found dual capacitor slightly weak. Found contactor burnt and pitted   Informed homeowners they decided to replace these parts so we don't have any concern of a break down before next maintenance visit. 

Solution: 
Replace capacitor 
Replace contactor 
1 year parts and labor warranty on repair
Reason for call:
Member tune up 

Summary:
Completed maintenance unit is operating well unit had 20 degree split. Flushed drain line and pan. Flushed indoor and outdoor coils. Changed filter. Homeowner needs to order more filters. 20x20x1
Found dual capacitor slightly weak. Found contactor burnt and pitted   Informed homeowners they decided to replace these parts so we don't have any concern of a break down before next maintenance visit. 

Solution: 
Replace capacitor 
Replace contactor 
1 year parts and labor warranty on repair
Corbin C.
Corbin C. Checked in
Reason for call: Member tune up Summary: Completed maintenance unit is operating well unit had 20 degree split. Flushed drain line and pan. Flushed indoor and outdoor coils. Changed filter. Homeowner needs to order more filters. 20x20x1 Found dual capacitor slightly weak. Found contactor burnt and pitted Informed homeowners they decided to replace these parts so we don't have any concern of a break down before next maintenance visit. Solution: Replace capacitor Replace contactor 1 year parts and labor warranty on repair
Clearwater, FL 33760
Found water source heat pump system tripped on high pressure fault. 
Attempted to restart system and when the compressor turned on, the breaker panel started making a bad noise and then started smoking. I immediately turned off the AC breaker to prevent further damage. 
Scheduling for Electrician to come out to diagnose breaker panel issue. 
$95 service fee collected for initial visit. Will not charge $95 again for electrician or return hvac diagnosis.
Found water source heat pump system tripped on high pressure fault. 
Attempted to restart system and when the compressor turned on, the breaker panel started making a bad noise and then started smoking. I immediately turned off the AC breaker to prevent further damage. 
Scheduling for Electrician to come out to diagnose breaker panel issue. 
$95 service fee collected for initial visit. Will not charge $95 again for electrician or return hvac diagnosis.
Michael A.
Michael A. Checked in
Found water source heat pump system tripped on high pressure fault. Attempted to restart system and when the compressor turned on, the breaker panel started making a bad noise and then started smoking. I immediately turned off the AC breaker to prevent further damage. Scheduling for Electrician to come out to diagnose breaker panel issue. $95 service fee collected for initial visit. Will not charge $95 again for electrician or return hvac diagnosis.
Clearwater, FL 33756
- Performed HVAC inspection. 
- System: 2017 Trane Heat pump with 5Kw heater
- Verifier correct breaker sizes
- Verified safety float switches work
- System is cooling with a 23° temperature split
- Amp draw on the compressor is within range
- Amp draw on condenser fan motor is over the max allowed. Reading .88 amps with a max rating allowed it .64. 
Fan motor is at high risk of completely failing at any given moment. This is an inefficiency. Fan motor is currently running at this time. Will provide a quote to replace fan motor for knowledge of what to expect in costs when the fan motor does fail completely. 
- Capacitor tested within manufacture range
- Contactar is working as it should
- Inspected Inside air handler and found a Severely dirty blower wheel and housing. (See attached photos). This causes inefficient air flow within the home, puts added weight on the fan blades which can throw off the balance of the blower wheel and add extra stress on the indoor fan motor. This is an i
- Performed HVAC inspection. 
- System: 2017 Trane Heat pump with 5Kw heater
- Verifier correct breaker sizes
- Verified safety float switches work
- System is cooling with a 23° temperature split
- Amp draw on the compressor is within range
- Amp draw on condenser fan motor is over the max allowed. Reading .88 amps with a max rating allowed it .64. 
Fan motor is at high risk of completely failing at any given moment. This is an inefficiency. Fan motor is currently running at this time. Will provide a quote to replace fan motor for knowledge of what to expect in costs when the fan motor does fail completely. 
- Capacitor tested within manufacture range
- Contactar is working as it should
- Inspected Inside air handler and found a Severely dirty blower wheel and housing. (See attached photos). This causes inefficient air flow within the home, puts added weight on the fan blades which can throw off the balance of the blower wheel and add extra stress on the indoor fan motor. This is an i
Michael A.
Michael A. Checked in
- Performed HVAC inspection. - System: 2017 Trane Heat pump with 5Kw heater - Verifier correct breaker sizes - Verified safety float switches work - System is cooling with a 23° temperature split - Amp draw on the compressor is within range - Amp draw on condenser fan motor is over the max allowed. Reading .88 amps with a max rating allowed it .64. Fan motor is at high risk of completely failing at any given moment. This is an inefficiency. Fan motor is currently running at this time. Will provide a quote to replace fan motor for knowledge of what to expect in costs when the fan motor does fail completely. - Capacitor tested within manufacture range - Contactar is working as it should - Inspected Inside air handler and found a Severely dirty blower wheel and housing. (See attached photos). This causes inefficient air flow within the home, puts added weight on the fan blades which can throw off the balance of the blower wheel and add extra stress on the indoor fan motor. This is an i
Clearwater, FL 33764
Goodman 5 ton straight cool
10 kw heat
10 year parts warranty
5 year labor warranty
All warranties fully transferable 
-Adjustable air handler stand
-Permit
-Hurricane pad
-Hurricane tiedowns
-Filter for unit 
-Safety switch 
-UV rated armorflex 

Also 2 ton straight cool
Unit in back
Same warranties 
Same specs
-Ducted stand instead of adjustable

**Clean air handler closets**
Goodman 5 ton straight cool
10 kw heat
10 year parts warranty
5 year labor warranty
All warranties fully transferable 
-Adjustable air handler stand
-Permit
-Hurricane pad
-Hurricane tiedowns
-Filter for unit 
-Safety switch 
-UV rated armorflex 

Also 2 ton straight cool
Unit in back
Same warranties 
Same specs
-Ducted stand instead of adjustable

**Clean air handler closets**
Ricky O.
Ricky O. Checked in
Goodman 5 ton straight cool 10 kw heat 10 year parts warranty 5 year labor warranty All warranties fully transferable -Adjustable air handler stand -Permit -Hurricane pad -Hurricane tiedowns -Filter for unit -Safety switch -UV rated armorflex Also 2 ton straight cool Unit in back Same warranties Same specs -Ducted stand instead of adjustable **Clean air handler closets**
Clearwater, FL 33755
Reason for call:
No cool 

Summary:
Found fan on condenser not operating. Found dead fan capacitor. Replaced capacitor. To find fan motor is rotating backwards. This is causing large inefficiencies in the equipment. Also shows that fan motor is on borrowed time. 
Quoted system replacement to prevent down time on equipment. 
Unit is cooling at this time.
Reason for call:
No cool 

Summary:
Found fan on condenser not operating. Found dead fan capacitor. Replaced capacitor. To find fan motor is rotating backwards. This is causing large inefficiencies in the equipment. Also shows that fan motor is on borrowed time. 
Quoted system replacement to prevent down time on equipment. 
Unit is cooling at this time.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: Found fan on condenser not operating. Found dead fan capacitor. Replaced capacitor. To find fan motor is rotating backwards. This is causing large inefficiencies in the equipment. Also shows that fan motor is on borrowed time. Quoted system replacement to prevent down time on equipment. Unit is cooling at this time.
Clearwater, FL 33764
1143896

Client states system stopped working Friday morning. Upon my inspection, found two error codes. 
Outdoor condenser giving 11 blink code for Power control board issues with communication. 
Indoor living room head unit giving 3 blink code for Rotation frequency feedback signal is not emitted during the indoor fan operation. 
Found indoor blower wheel not in balance and likely the fan motor shaft is bent and causing the unit to vibrate violently when in high fan speed. 
Client did recently take apart head unit to clean the blower wheel. 

System is 12 years old and out of warranty. 
If client would like to proceed with repairs, we will need to charge our tech support fee to spend the time with tech support during normal business hours in order to accurately determine a solution. At this time the power control boards are not communicating. 

Client needs to speak with the owner to determine if they would like to repair or replace this system. 

I made sure client is aware that rep
1143896

Client states system stopped working Friday morning. Upon my inspection, found two error codes. 
Outdoor condenser giving 11 blink code for Power control board issues with communication. 
Indoor living room head unit giving 3 blink code for Rotation frequency feedback signal is not emitted during the indoor fan operation. 
Found indoor blower wheel not in balance and likely the fan motor shaft is bent and causing the unit to vibrate violently when in high fan speed. 
Client did recently take apart head unit to clean the blower wheel. 

System is 12 years old and out of warranty. 
If client would like to proceed with repairs, we will need to charge our tech support fee to spend the time with tech support during normal business hours in order to accurately determine a solution. At this time the power control boards are not communicating. 

Client needs to speak with the owner to determine if they would like to repair or replace this system. 

I made sure client is aware that rep
Michael A.
Michael A. Checked in
1143896 Client states system stopped working Friday morning. Upon my inspection, found two error codes. Outdoor condenser giving 11 blink code for Power control board issues with communication. Indoor living room head unit giving 3 blink code for Rotation frequency feedback signal is not emitted during the indoor fan operation. Found indoor blower wheel not in balance and likely the fan motor shaft is bent and causing the unit to vibrate violently when in high fan speed. Client did recently take apart head unit to clean the blower wheel. System is 12 years old and out of warranty. If client would like to proceed with repairs, we will need to charge our tech support fee to spend the time with tech support during normal business hours in order to accurately determine a solution. At this time the power control boards are not communicating. Client needs to speak with the owner to determine if they would like to repair or replace this system. I made sure client is aware that rep
Clearwater, FL 33756
Clients electrician bypassed air handler breaker on heating kit. 
I found that thermostat was set to heat and 60° which was not allowing for system to turn on in cooling mode. 
Started system and found condenser fan motor spinning backwards. Found fan motor was wired improperly. Also found two weak capacitors. Replaced capacitors with a turbo 200 capacitor and fixed fan motor wiring. Found system low 1 lb of refrigerant. Added 1 lb and brought the 16° temp split to a 19° temp split. 
Client signed up for Maitenence plan and I performed first Maitenence today. Cleaned drain line and cleaned condenser coils. 
System has good amp draws. 
System is cooling and draining at this time.
Clients electrician bypassed air handler breaker on heating kit. 
I found that thermostat was set to heat and 60° which was not allowing for system to turn on in cooling mode. 
Started system and found condenser fan motor spinning backwards. Found fan motor was wired improperly. Also found two weak capacitors. Replaced capacitors with a turbo 200 capacitor and fixed fan motor wiring. Found system low 1 lb of refrigerant. Added 1 lb and brought the 16° temp split to a 19° temp split. 
Client signed up for Maitenence plan and I performed first Maitenence today. Cleaned drain line and cleaned condenser coils. 
System has good amp draws. 
System is cooling and draining at this time.
Michael A.
Michael A. Checked in
Clients electrician bypassed air handler breaker on heating kit. I found that thermostat was set to heat and 60° which was not allowing for system to turn on in cooling mode. Started system and found condenser fan motor spinning backwards. Found fan motor was wired improperly. Also found two weak capacitors. Replaced capacitors with a turbo 200 capacitor and fixed fan motor wiring. Found system low 1 lb of refrigerant. Added 1 lb and brought the 16° temp split to a 19° temp split. Client signed up for Maitenence plan and I performed first Maitenence today. Cleaned drain line and cleaned condenser coils. System has good amp draws. System is cooling and draining at this time.
Clearwater, FL 33762
Diagnostic 
-pump safety triggered short cycled outdoor unit 
-outdoor coils sensor failed (led lit up on defrost board) (recommend replacing) 

Resent pump and cleared pump properly 

System began to run , found system low on refrigerant (15° temperature split) (system is 15 years of age) (went over system having potential leak)

Further Notes
-aftermarket green motor in air handler 
-bacterial growth inside air handler and blower wheel 
-defrost board has heat exhaustion across terminals 
-outdoor condenser coils need to be cleaned 

Went over current repairs and potential future repairs. Went over age of system. Home owner would like to repair and monitor system incase of leak. Will submit estimates for further repairs. 

Charged system back to factory specifications 

Verified system operations
Diagnostic 
-pump safety triggered short cycled outdoor unit 
-outdoor coils sensor failed (led lit up on defrost board) (recommend replacing) 

Resent pump and cleared pump properly 

System began to run , found system low on refrigerant (15° temperature split) (system is 15 years of age) (went over system having potential leak)

Further Notes
-aftermarket green motor in air handler 
-bacterial growth inside air handler and blower wheel 
-defrost board has heat exhaustion across terminals 
-outdoor condenser coils need to be cleaned 

Went over current repairs and potential future repairs. Went over age of system. Home owner would like to repair and monitor system incase of leak. Will submit estimates for further repairs. 

Charged system back to factory specifications 

Verified system operations
Nathan A.
Nathan A. Checked in
Diagnostic -pump safety triggered short cycled outdoor unit -outdoor coils sensor failed (led lit up on defrost board) (recommend replacing) Resent pump and cleared pump properly System began to run , found system low on refrigerant (15° temperature split) (system is 15 years of age) (went over system having potential leak) Further Notes -aftermarket green motor in air handler -bacterial growth inside air handler and blower wheel -defrost board has heat exhaustion across terminals -outdoor condenser coils need to be cleaned Went over current repairs and potential future repairs. Went over age of system. Home owner would like to repair and monitor system incase of leak. Will submit estimates for further repairs. Charged system back to factory specifications Verified system operations
Clearwater, FL 33764
Reason for call:
No cool 

Summary:
Found no low voltage to condenser. 
Found loose common wire inside air handler. 
Redid wire connections. 
Operation was restore to equipment. 
Confirmed proper temperature, pressures, and amp draws. 
Unit is cooling well at this time.
Reason for call:
No cool 

Summary:
Found no low voltage to condenser. 
Found loose common wire inside air handler. 
Redid wire connections. 
Operation was restore to equipment. 
Confirmed proper temperature, pressures, and amp draws. 
Unit is cooling well at this time.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: Found no low voltage to condenser. Found loose common wire inside air handler. Redid wire connections. Operation was restore to equipment. Confirmed proper temperature, pressures, and amp draws. Unit is cooling well at this time.
Clearwater, FL 33764
Summary:
On arrival found drain line clogged. Client had mini split turned off.
Flushed and clean, drain line and drain pan. Maintenance is not due quite yet. We will be back in a few months to take care of the  maintenance. Operation was restored to equipment unit has 28 degree temperature difference.
Summary:
On arrival found drain line clogged. Client had mini split turned off.
Flushed and clean, drain line and drain pan. Maintenance is not due quite yet. We will be back in a few months to take care of the  maintenance. Operation was restored to equipment unit has 28 degree temperature difference.
Corbin C.
Corbin C. Checked in
Summary: On arrival found drain line clogged. Client had mini split turned off. Flushed and clean, drain line and drain pan. Maintenance is not due quite yet. We will be back in a few months to take care of the maintenance. Operation was restored to equipment unit has 28 degree temperature difference.
Clearwater, FL 33759
Reason for call:
No cool 

Equipment:
2017 Icp 
Vertical in closet 
Condenser out back 

Summary:
Found unit not cooling properly. Found very high suction pressure. Compressor is failing to pump properly. This cuases lack of cooling and high suction pressure compressor will have to be replaced at this time. Informed homeowner of replacement vs. repair option. They just wanted repair option.
Reason for call:
No cool 

Equipment:
2017 Icp 
Vertical in closet 
Condenser out back 

Summary:
Found unit not cooling properly. Found very high suction pressure. Compressor is failing to pump properly. This cuases lack of cooling and high suction pressure compressor will have to be replaced at this time. Informed homeowner of replacement vs. repair option. They just wanted repair option.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Equipment: 2017 Icp Vertical in closet Condenser out back Summary: Found unit not cooling properly. Found very high suction pressure. Compressor is failing to pump properly. This cuases lack of cooling and high suction pressure compressor will have to be replaced at this time. Informed homeowner of replacement vs. repair option. They just wanted repair option.
Clearwater, FL 33759
Reason for call:
No cool 

Summary:
On arrival found drain line clogged unit is cooling properly. Filters need to be updated and maintained better. 
Cleared drain lien to restore proper operation to drainage. 
Informed homeowner about adjusting air flow at the vents to see if it improves air flow in back bedroom. 
Do duct work inspection on pm.
Reason for call:
No cool 

Summary:
On arrival found drain line clogged unit is cooling properly. Filters need to be updated and maintained better. 
Cleared drain lien to restore proper operation to drainage. 
Informed homeowner about adjusting air flow at the vents to see if it improves air flow in back bedroom. 
Do duct work inspection on pm.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: On arrival found drain line clogged unit is cooling properly. Filters need to be updated and maintained better. Cleared drain lien to restore proper operation to drainage. Informed homeowner about adjusting air flow at the vents to see if it improves air flow in back bedroom. Do duct work inspection on pm.
Clearwater, FL 33761
Upon my inspection, found system, turning off due to a clogged drain line in a tripped primary float switch. Performed drain cleaning and treatment on system. Found the media air filter has not been changed since it was installed. I let Client know this needs to be changed as soon as possible. Client signed up for maintenance plan. Temperature split is 20° and I cleaned the condenser coils. System is cooling and draining at this time.
Upon my inspection, found system, turning off due to a clogged drain line in a tripped primary float switch. Performed drain cleaning and treatment on system. Found the media air filter has not been changed since it was installed. I let Client know this needs to be changed as soon as possible. Client signed up for maintenance plan. Temperature split is 20° and I cleaned the condenser coils. System is cooling and draining at this time.
Michael A.
Michael A. Checked in
Upon my inspection, found system, turning off due to a clogged drain line in a tripped primary float switch. Performed drain cleaning and treatment on system. Found the media air filter has not been changed since it was installed. I let Client know this needs to be changed as soon as possible. Client signed up for maintenance plan. Temperature split is 20° and I cleaned the condenser coils. System is cooling and draining at this time.
Clearwater, FL 33764
Client states home seems to not cool down as fast as it used to. 
I found system cooling with a good 20° temperature split. system is 14 years old. Attic is not completely insulated properly. I let client know this system is old and not as efficient as it once was and is doing all it can to cool the home. We are experiencing very hot weather this year and with older windows and poor attic insulation, the system can only do so much. Recommended preparing for a new system in the future and getting the attic insulated properly. 

Client cleaned his own drain and changes his own parts such as the capacitor. 
System is cooling and draining at this time.
Client states home seems to not cool down as fast as it used to. 
I found system cooling with a good 20° temperature split. system is 14 years old. Attic is not completely insulated properly. I let client know this system is old and not as efficient as it once was and is doing all it can to cool the home. We are experiencing very hot weather this year and with older windows and poor attic insulation, the system can only do so much. Recommended preparing for a new system in the future and getting the attic insulated properly. 

Client cleaned his own drain and changes his own parts such as the capacitor. 
System is cooling and draining at this time.
Michael A.
Michael A. Checked in
Client states home seems to not cool down as fast as it used to. I found system cooling with a good 20° temperature split. system is 14 years old. Attic is not completely insulated properly. I let client know this system is old and not as efficient as it once was and is doing all it can to cool the home. We are experiencing very hot weather this year and with older windows and poor attic insulation, the system can only do so much. Recommended preparing for a new system in the future and getting the attic insulated properly. Client cleaned his own drain and changes his own parts such as the capacitor. System is cooling and draining at this time.
Clearwater, FL 33763
Scope of work:
- Install Solar fan on peak of roof above air handler
- Electrical included
- Completely seal attic fan penetration point
$1150 original. 
$1035 member discount
Scope of work:
- Install Solar fan on peak of roof above air handler
- Electrical included
- Completely seal attic fan penetration point
$1150 original. 
$1035 member discount
Martin W.
Martin W. Checked in
Scope of work: - Install Solar fan on peak of roof above air handler - Electrical included - Completely seal attic fan penetration point $1150 original. $1035 member discount
Clearwater, FL 33764
Reason for call:
No cool 

Summary:
Found clogged drain 
Cleared line operation was restored to equipment. 
Office will be reaching out shortly to schedule full building pm.
Reason for call:
No cool 

Summary:
Found clogged drain 
Cleared line operation was restored to equipment. 
Office will be reaching out shortly to schedule full building pm.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: Found clogged drain Cleared line operation was restored to equipment. Office will be reaching out shortly to schedule full building pm.
Clearwater, FL 33762
Reason for call:
No cool 

Equipment:
2018 American standard
Vertical in closet 
Condenser out back 

Summary:
Found unit off on saftey. Performed full inspection of equipment and found it operating within manufacturing specifications. Flushed drain line and pan restored operation to equipment.
Reason for call:
No cool 

Equipment:
2018 American standard
Vertical in closet 
Condenser out back 

Summary:
Found unit off on saftey. Performed full inspection of equipment and found it operating within manufacturing specifications. Flushed drain line and pan restored operation to equipment.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Equipment: 2018 American standard Vertical in closet Condenser out back Summary: Found unit off on saftey. Performed full inspection of equipment and found it operating within manufacturing specifications. Flushed drain line and pan restored operation to equipment.
Clearwater, FL 33763
Clearwater, FL - Install disconnect for water heater
Griffin K.
Griffin K. Checked in
Install disconnect for water heater
Clearwater, FL 33756
Clearwater, FL - Install customer supplied time clock
Griffin K.
Griffin K. Checked in
Install customer supplied time clock
Clearwater, FL 33756
Clearwater, FL - On arrival found unit leaking water due to clogged drain and failed float switch for upstairs unit. Cleared pan and drain. Added chemical to help prevent growth in pan. Replaced float switches and tested. Cleared downstairs unit drain as well. Both units running and cooling properly at this time. Recommend for client to have regular maintenance on system to prevent future issues.
Justin G.
Justin G. Checked in
On arrival found unit leaking water due to clogged drain and failed float switch for upstairs unit. Cleared pan and drain. Added chemical to help prevent growth in pan. Replaced float switches and tested. Cleared downstairs unit drain as well. Both units running and cooling properly at this time. Recommend for client to have regular maintenance on system to prevent future issues.
Clearwater, FL 33761
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is not within factory range. Inspected Contactar for weak points. Found contactar weak. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. Air purifier is on and working. 

Replaced contactar and capacitor. Made all connections tight. 
System is cooling properly at this time.
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is not within factory range. Inspected Contactar for weak points. Found contactar weak. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. Air purifier is on and working. 

Replaced contactar and capacitor. Made all connections tight. 
System is cooling properly at this time.
Michael A.
Michael A. Checked in
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is not within factory range. Inspected Contactar for weak points. Found contactar weak. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. Air purifier is on and working. Replaced contactar and capacitor. Made all connections tight. System is cooling properly at this time.
Clearwater, FL 33755