Instant Quote Shop Filters Call Air Bros

Largo, FL

air-bros-team-with-truck

Largo, FL, Home Comfort Solutions

As a locally owned and operated company, Air Bros is proud to be a part of the Largo community. We understand the challenges that Florida's heat and humidity can bring, and we're dedicated to providing our neighbors with reliable HVAC solutions to keep their homes comfortable year-round. Whether you're just steps from the Gulf or nestled in a quiet neighborhood, you can count on Air Bros for top-notch service and personalized solutions.

Call us at 727-217-6148 or contact us online.

Why Choose Air Bros in Largo?

  • Local Expertise: We're familiar with the unique climate challenges of Largo and the specific needs of its residents.
  • Customer-Focused Approach: Your comfort and satisfaction are our top priorities. We listen to your concerns, answer your questions, and provide tailored solutions that fit your needs and budget.
  • Experienced and Certified Technicians: Our team consists of highly skilled and certified technicians with extensive experience in all aspects of HVAC service. You can trust us to get the job done right.
  • Fast and Reliable Service: We know that HVAC issues can be disruptive. That's why we prioritize prompt and reliable service, offering same-day service for AC emergencies and quick response times for all your HVAC needs.
  • Upfront Pricing: We believe in transparency and honesty. You'll always receive upfront pricing with no hidden costs or surprises.

Comprehensive HVAC Services in Largo, FL

  • Complete Comfort Solutions: We're your one-stop shop for heating and cooling in Largo. Whether you need AC repair on a scorching summer day or a new furnace installed before winter arrives, our expert technicians have you covered. We service all makes and models, ensuring your home stays comfortable no matter the season.
  • Healthy Indoor Air: We go beyond temperature control to ensure the air you breathe is clean and healthy. Our indoor air quality solutions, including dehumidifiers and UV light air purifiers, help control humidity, eliminate allergens, and create a healthier home environment for you and your family.
  • Efficient Airflow: Your ductwork plays a crucial role in your home's comfort and energy efficiency. Our professional ductwork services ensure optimal airflow, prevent energy waste, and improve the overall performance of your HVAC system.

Beyond the Basics

  • Pool Heater Services: Enjoy your pool year-round with our pool heater installation and repair services.
  • Electrical Services: We can handle your electrical needs, including outlet and switch replacements, ceiling fan installations, and whole-house surge protector installations.

Contact Air Bros Today!

We're your trusted HVAC partner in Largo. Contact us today for a free consultation or to schedule a service appointment. Experience the Air Bros difference!

Call us at 727-217-6148 or contact us online.

Recent Jobs and Reviews in Largo, FL

Largo, FL at a glance

Air Bros Air Conditioning & Electrical has completed 25 jobs in Largo, FL between September 2026 and November 2026.

The most recent job was on November 19, 2026.

Air Bros Air Conditioning & Electrical has completed 106 jobs in Largo, FL in the last 12 months. The first job there was in February 2025.

Job Locations and Reviews

Remove and clean evaporator coils in attic
New liquid line filter drier
Add 2 lbs refrigerant to bring pressures back to factory spec. 
System now has a 20° temperature split. Pressures are great. System held a proper vacuum at 500 microns.
Remove and clean evaporator coils in attic
New liquid line filter drier
Add 2 lbs refrigerant to bring pressures back to factory spec. 
System now has a 20° temperature split. Pressures are great. System held a proper vacuum at 500 microns.
Michael A.
Michael A. Checked in
Remove and clean evaporator coils in attic New liquid line filter drier Add 2 lbs refrigerant to bring pressures back to factory spec. System now has a 20° temperature split. Pressures are great. System held a proper vacuum at 500 microns.
Largo, FL 33774
Home owner states heat is not working in home

Straight cool system 

Found white wires not terminated on splice 

Terminated wires and verified heat operations 

Verified cooling operations
Home owner states heat is not working in home

Straight cool system 

Found white wires not terminated on splice 

Terminated wires and verified heat operations 

Verified cooling operations
Nathan A.
Nathan A. Checked in
Home owner states heat is not working in home Straight cool system Found white wires not terminated on splice Terminated wires and verified heat operations Verified cooling operations
Largo, FL 33778
System not cooling due to system running in heat pump mode. 
Found corroded low voltage wires at condenser. Reversing valve not receiving 24v due to broken off o/b wire. 
Made necessary repairs on wiring. 

Started system. System is cooling with a 15° temperature split. 
Found suction line shrader valve core leaking refrigerant. Replaced valve core. 

Found evaporator coils extremely dirty and need a removal/cleaning. 
Will need to add refrigerant after coils are cleaned. 

Found drain line is improperly sized. Recommending replacement. 

Found capacitor weak. Replaced capacitor

Found drain line connections at unit not glued and a potential water leak hazard. Glued connections complimentary. 

Found return in master bedroom has no filter or filter back grill causing excessive debris to enter the air handler and clog up the coils. Client says the hallway filter grill does not fit normal 12x12 filters. 
Recommended replacing both filter back grills. 

Client signed up for Maitenence pla
System not cooling due to system running in heat pump mode. 
Found corroded low voltage wires at condenser. Reversing valve not receiving 24v due to broken off o/b wire. 
Made necessary repairs on wiring. 

Started system. System is cooling with a 15° temperature split. 
Found suction line shrader valve core leaking refrigerant. Replaced valve core. 

Found evaporator coils extremely dirty and need a removal/cleaning. 
Will need to add refrigerant after coils are cleaned. 

Found drain line is improperly sized. Recommending replacement. 

Found capacitor weak. Replaced capacitor

Found drain line connections at unit not glued and a potential water leak hazard. Glued connections complimentary. 

Found return in master bedroom has no filter or filter back grill causing excessive debris to enter the air handler and clog up the coils. Client says the hallway filter grill does not fit normal 12x12 filters. 
Recommended replacing both filter back grills. 

Client signed up for Maitenence pla
Michael A.
Michael A. Checked in
System not cooling due to system running in heat pump mode. Found corroded low voltage wires at condenser. Reversing valve not receiving 24v due to broken off o/b wire. Made necessary repairs on wiring. Started system. System is cooling with a 15° temperature split. Found suction line shrader valve core leaking refrigerant. Replaced valve core. Found evaporator coils extremely dirty and need a removal/cleaning. Will need to add refrigerant after coils are cleaned. Found drain line is improperly sized. Recommending replacement. Found capacitor weak. Replaced capacitor Found drain line connections at unit not glued and a potential water leak hazard. Glued connections complimentary. Found return in master bedroom has no filter or filter back grill causing excessive debris to enter the air handler and clog up the coils. Client says the hallway filter grill does not fit normal 12x12 filters. Recommended replacing both filter back grills. Client signed up for Maitenence pla
Largo, FL 33774
Diagnostic 
-drain line backing up causing safety to shut off system 

Air Handler Notes
-light debris on back side of coils 
-coils starting to corrode/rust 
-bacterial growth on blower wheel/assembly 

Outdoor Unit Notes 
-SC out of range and temp split lower indicating low on refrigerant (home owner states unit was filled last year)
-system has leak 
-outdoor coils starting to corrode 

Went over repair and replacement options with home owner. Home owner will clear drain line 

Credit 95$ towards system replacement if completed within 30 days of visit
Diagnostic 
-drain line backing up causing safety to shut off system 

Air Handler Notes
-light debris on back side of coils 
-coils starting to corrode/rust 
-bacterial growth on blower wheel/assembly 

Outdoor Unit Notes 
-SC out of range and temp split lower indicating low on refrigerant (home owner states unit was filled last year)
-system has leak 
-outdoor coils starting to corrode 

Went over repair and replacement options with home owner. Home owner will clear drain line 

Credit 95$ towards system replacement if completed within 30 days of visit
Nathan A.
Nathan A. Checked in
Diagnostic -drain line backing up causing safety to shut off system Air Handler Notes -light debris on back side of coils -coils starting to corrode/rust -bacterial growth on blower wheel/assembly Outdoor Unit Notes -SC out of range and temp split lower indicating low on refrigerant (home owner states unit was filled last year) -system has leak -outdoor coils starting to corrode Went over repair and replacement options with home owner. Home owner will clear drain line Credit 95$ towards system replacement if completed within 30 days of visit
Largo, FL 33774
System not cooling due to dead rat and fried contactar and capacitor. Rat was laying across components. 
Condenser breaker was in the tripped position. 

*Bio Hazard* Removed Rat, disinfected and wiped down all debris from rat on wiring and electrical service panel. Replaced capacitor and Contactar. 
Started system and verified system is cooling at this time.  

Found two large holes where wires run through in condenser and closed up holes with tape to try and prevent this issue from reoccurring. These holes are factory made. 

Replaced clients air filter while on site.
System not cooling due to dead rat and fried contactar and capacitor. Rat was laying across components. 
Condenser breaker was in the tripped position. 

*Bio Hazard* Removed Rat, disinfected and wiped down all debris from rat on wiring and electrical service panel. Replaced capacitor and Contactar. 
Started system and verified system is cooling at this time.  

Found two large holes where wires run through in condenser and closed up holes with tape to try and prevent this issue from reoccurring. These holes are factory made. 

Replaced clients air filter while on site.
Michael A.
Michael A. Checked in
System not cooling due to dead rat and fried contactar and capacitor. Rat was laying across components. Condenser breaker was in the tripped position. *Bio Hazard* Removed Rat, disinfected and wiped down all debris from rat on wiring and electrical service panel. Replaced capacitor and Contactar. Started system and verified system is cooling at this time. Found two large holes where wires run through in condenser and closed up holes with tape to try and prevent this issue from reoccurring. These holes are factory made. Replaced clients air filter while on site.
Largo, FL 33771
Inspected home for high humidity. Used amp probe and found home was 50% humidity throughout where thermostat was reading 80% plus. Performed maintenance on system. Rinsed condenser coil. Temp splits good. Cleared pan and drain. Found water sitting below blower due to improper drain tube. Showed client level drain should be at. Made client aware to leave fan running to dry insulation for 3 days. Amp draws good. Unit operating properly at this time.
Inspected home for high humidity. Used amp probe and found home was 50% humidity throughout where thermostat was reading 80% plus. Performed maintenance on system. Rinsed condenser coil. Temp splits good. Cleared pan and drain. Found water sitting below blower due to improper drain tube. Showed client level drain should be at. Made client aware to leave fan running to dry insulation for 3 days. Amp draws good. Unit operating properly at this time.
Justin G.
Justin G. Checked in
Inspected home for high humidity. Used amp probe and found home was 50% humidity throughout where thermostat was reading 80% plus. Performed maintenance on system. Rinsed condenser coil. Temp splits good. Cleared pan and drain. Found water sitting below blower due to improper drain tube. Showed client level drain should be at. Made client aware to leave fan running to dry insulation for 3 days. Amp draws good. Unit operating properly at this time.
Largo, FL 33771
Reason for call:
No cool 

Summary:
On arrival found Condneser not turning on. 
Found dead capacitor. 
Homeowner mentioned he experienced a large power outage last night and that could relate to this repair. 

Solution:
Replaced the contactor and the capacitor on today's visit. 
There is one year parts and labor warranty on this repair. 

Confirmed proper temperature unit is cooling by 20 degrees. 
Confirmed proper amp draws. Equipment did not take any further damage. 

Maintenance visit will be scheduled soon
Reason for call:
No cool 

Summary:
On arrival found Condneser not turning on. 
Found dead capacitor. 
Homeowner mentioned he experienced a large power outage last night and that could relate to this repair. 

Solution:
Replaced the contactor and the capacitor on today's visit. 
There is one year parts and labor warranty on this repair. 

Confirmed proper temperature unit is cooling by 20 degrees. 
Confirmed proper amp draws. Equipment did not take any further damage. 

Maintenance visit will be scheduled soon
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: On arrival found Condneser not turning on. Found dead capacitor. Homeowner mentioned he experienced a large power outage last night and that could relate to this repair. Solution: Replaced the contactor and the capacitor on today's visit. There is one year parts and labor warranty on this repair. Confirmed proper temperature unit is cooling by 20 degrees. Confirmed proper amp draws. Equipment did not take any further damage. Maintenance visit will be scheduled soon
Largo, FL 33773
Upon arrival, I began by performing maintenance, including cleaning the drain pan, clearing the drain line, and cleaning the condenser coils.

I then inspected the system and measured a 13°F temperature split between the supply and return air. Upon checking the refrigerant cycle, I found elevated liquid pressure and high subcooling, indicating a possible restriction at the TXV. The electrical components were operating properly, and the compressor and fan motor were operating within their rated amperage.

Both systems are currently operational; however, they are mismatched, with one system installed in 2007 and the other in 2012. Both units are out of warranty. I discussed the findings with the homeowner and explained that, given the age of the equipment and the potential risks and costs associated with repairs, system replacement would be the most practical long-term option.

The homeowner would like time to consider the options and requested that we follow up next week.

If you have a
Upon arrival, I began by performing maintenance, including cleaning the drain pan, clearing the drain line, and cleaning the condenser coils.

I then inspected the system and measured a 13°F temperature split between the supply and return air. Upon checking the refrigerant cycle, I found elevated liquid pressure and high subcooling, indicating a possible restriction at the TXV. The electrical components were operating properly, and the compressor and fan motor were operating within their rated amperage.

Both systems are currently operational; however, they are mismatched, with one system installed in 2007 and the other in 2012. Both units are out of warranty. I discussed the findings with the homeowner and explained that, given the age of the equipment and the potential risks and costs associated with repairs, system replacement would be the most practical long-term option.

The homeowner would like time to consider the options and requested that we follow up next week.

If you have a
Ace m.
Ace m. Checked in
Upon arrival, I began by performing maintenance, including cleaning the drain pan, clearing the drain line, and cleaning the condenser coils. I then inspected the system and measured a 13°F temperature split between the supply and return air. Upon checking the refrigerant cycle, I found elevated liquid pressure and high subcooling, indicating a possible restriction at the TXV. The electrical components were operating properly, and the compressor and fan motor were operating within their rated amperage. Both systems are currently operational; however, they are mismatched, with one system installed in 2007 and the other in 2012. Both units are out of warranty. I discussed the findings with the homeowner and explained that, given the age of the equipment and the potential risks and costs associated with repairs, system replacement would be the most practical long-term option. The homeowner would like time to consider the options and requested that we follow up next week. If you have a
Largo, FL 33778
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is not within factory range and very rusted. While testing, terminal broke off due to rust. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.

System heating kit is poorly bypassed. Let client know. System is heat pump so it can still heat. 

System is over 10 years old and not in warranty anymore. 

Replaced capacitor.
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is not within factory range and very rusted. While testing, terminal broke off due to rust. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.

System heating kit is poorly bypassed. Let client know. System is heat pump so it can still heat. 

System is over 10 years old and not in warranty anymore. 

Replaced capacitor.
Michael A.
Michael A. Checked in
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is not within factory range and very rusted. While testing, terminal broke off due to rust. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. System heating kit is poorly bypassed. Let client know. System is heat pump so it can still heat. System is over 10 years old and not in warranty anymore. Replaced capacitor.
Largo, FL 33771
Low-voltage repair plus the maintenance plan. Owner’s dog chewed through the low-voltage wires cutting connection to the air handler. Perform the repair and everything is working properly with a 20° temperature difference.
Low-voltage repair plus the maintenance plan. Owner’s dog chewed through the low-voltage wires cutting connection to the air handler. Perform the repair and everything is working properly with a 20° temperature difference.
Ace m.
Ace m. Checked in
Low-voltage repair plus the maintenance plan. Owner’s dog chewed through the low-voltage wires cutting connection to the air handler. Perform the repair and everything is working properly with a 20° temperature difference.
Largo, FL 33773
Reason for call:
Water leak/ tune up 

Summary:
Found drain line clogged. 
Found excessive growth with air handler
Performed tune up 
Confirmed proper drainage 
Confirmed proper temperature 
Confirmed amp draws 
Confirmed capacitor readings
Checked pressures to find them slightly under manufacture specs. 
Inspected duct work to find some flex has been installed. But the majority of the duct work is original to the home. 

Solution 
Clean drain line 
Clean drain pan 
Informed homeowner to prepare for system replacement and ductwork replacement.
Reason for call:
Water leak/ tune up 

Summary:
Found drain line clogged. 
Found excessive growth with air handler
Performed tune up 
Confirmed proper drainage 
Confirmed proper temperature 
Confirmed amp draws 
Confirmed capacitor readings
Checked pressures to find them slightly under manufacture specs. 
Inspected duct work to find some flex has been installed. But the majority of the duct work is original to the home. 

Solution 
Clean drain line 
Clean drain pan 
Informed homeowner to prepare for system replacement and ductwork replacement.
Corbin C.
Corbin C. Checked in
Reason for call: Water leak/ tune up Summary: Found drain line clogged. Found excessive growth with air handler Performed tune up Confirmed proper drainage Confirmed proper temperature Confirmed amp draws Confirmed capacitor readings Checked pressures to find them slightly under manufacture specs. Inspected duct work to find some flex has been installed. But the majority of the duct work is original to the home. Solution Clean drain line Clean drain pan Informed homeowner to prepare for system replacement and ductwork replacement.
Largo, FL 33773
Michael A.
Michael A. Checked in
Found communication issue with leak detector device. Hard reset system. System is now cooling. If issue persists, we will need to replace refrigerant leak sensor. Let client know thermostat needs 2.4 g WiFi not 5g
Largo, FL 33774
System not cooling due to short to grounded compressor. 
Quote to replace system. 
Client stated there is also a leak in the evaporator coils.
System not cooling due to short to grounded compressor. 
Quote to replace system. 
Client stated there is also a leak in the evaporator coils.
Michael A.
Michael A. Checked in
System not cooling due to short to grounded compressor. Quote to replace system. Client stated there is also a leak in the evaporator coils.
Largo, FL 33770
2 new dedicated circuits to kitchen one for the microwave one for the data cabinet in the kitchen AFCI protection in panel 

New dedicated range circuit from the panel (4 wire circuit)

Re wire dishwasher circuit and install outlet under sink cabinet 
Run a new wire in cabinet for speakers
2 new dedicated circuits to kitchen one for the microwave one for the data cabinet in the kitchen AFCI protection in panel 

New dedicated range circuit from the panel (4 wire circuit)

Re wire dishwasher circuit and install outlet under sink cabinet 
Run a new wire in cabinet for speakers
Griffin K.
Griffin K. Checked in
2 new dedicated circuits to kitchen one for the microwave one for the data cabinet in the kitchen AFCI protection in panel New dedicated range circuit from the panel (4 wire circuit) Re wire dishwasher circuit and install outlet under sink cabinet Run a new wire in cabinet for speakers
Largo, FL 33774
Michael A.
Michael A. Checked in
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is not within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 22° temperature split at this time. Interior of air handler has bacterial growth present. Recommending a UV air purifier inside air handler to help prevent bacterial growth. Recommending replacing Capacitor to be preventative. Also sending info for our maintenance plan for a more cost effective and regular cleaning/checkup schedule with discounts.
Largo, FL 33773
Homeowner states unit is not cooling, roof leak leading to water next to air handler. Breakers shut off to system. 

Upon arrival performed visual inspection 

Found low voltage coming to outdoor unit but no high voltage 

Found Condneser breaker left off 

Turned power on to system and tested system operations 

Air Handler Notes 
-Bacterial growth on blower wheel/assembly 
-Bacterial growth inside air Handler cabinet 
-Secondary Drain Pan Heavily Rusted  

Condenser Notes 
-subcool value of 6.5 and system rated for 10 Subcool (unit is 1-2lb low on 410a refrigerant)
-outdoor condenser coils need to be chemically cleaned 
-outdoor suction line insulation deteriorating 

Repair Recommendations 
-Pull & Sanitize Blower Wheel 
-Sanitize Air Handler Interior Cabinet/Wiring 
-Install Air Purifier to Mitigate Bacterial Growth 
-Charge System 1-2lb 410a 
-Insulate Outdoor Suction Line 
-Chemical Rinse Outdoor Coils 
-Replace Secondary Drain Pan

System is 9 years of age (3T) and second owners
Homeowner states unit is not cooling, roof leak leading to water next to air handler. Breakers shut off to system. 

Upon arrival performed visual inspection 

Found low voltage coming to outdoor unit but no high voltage 

Found Condneser breaker left off 

Turned power on to system and tested system operations 

Air Handler Notes 
-Bacterial growth on blower wheel/assembly 
-Bacterial growth inside air Handler cabinet 
-Secondary Drain Pan Heavily Rusted  

Condenser Notes 
-subcool value of 6.5 and system rated for 10 Subcool (unit is 1-2lb low on 410a refrigerant)
-outdoor condenser coils need to be chemically cleaned 
-outdoor suction line insulation deteriorating 

Repair Recommendations 
-Pull & Sanitize Blower Wheel 
-Sanitize Air Handler Interior Cabinet/Wiring 
-Install Air Purifier to Mitigate Bacterial Growth 
-Charge System 1-2lb 410a 
-Insulate Outdoor Suction Line 
-Chemical Rinse Outdoor Coils 
-Replace Secondary Drain Pan

System is 9 years of age (3T) and second owners
Nathan A.
Nathan A. Checked in
Homeowner states unit is not cooling, roof leak leading to water next to air handler. Breakers shut off to system. Upon arrival performed visual inspection Found low voltage coming to outdoor unit but no high voltage Found Condneser breaker left off Turned power on to system and tested system operations Air Handler Notes -Bacterial growth on blower wheel/assembly -Bacterial growth inside air Handler cabinet -Secondary Drain Pan Heavily Rusted Condenser Notes -subcool value of 6.5 and system rated for 10 Subcool (unit is 1-2lb low on 410a refrigerant) -outdoor condenser coils need to be chemically cleaned -outdoor suction line insulation deteriorating Repair Recommendations -Pull & Sanitize Blower Wheel -Sanitize Air Handler Interior Cabinet/Wiring -Install Air Purifier to Mitigate Bacterial Growth -Charge System 1-2lb 410a -Insulate Outdoor Suction Line -Chemical Rinse Outdoor Coils -Replace Secondary Drain Pan System is 9 years of age (3T) and second owners
Largo, FL 33778
Reason for call:
No cool/ water leak 

Summary:
Completed inspection to find drain line fittings were not glued. 
Found proper operation from equipment. 
Found burnt up uv air treatment kit 
Inspected pan to find it in proper working order no cracks. 
Confirmed temperature 
Confirmed capacitor readings 
Unit is drain and cooling properly at this time homeowner plans to do once a year maintenance visits 

Solution:
Flushed and clean drain line 
Install proper drain insulation 
Drain repair 
Install uv air treatment with 1 year parts and labor warranty
Reason for call:
No cool/ water leak 

Summary:
Completed inspection to find drain line fittings were not glued. 
Found proper operation from equipment. 
Found burnt up uv air treatment kit 
Inspected pan to find it in proper working order no cracks. 
Confirmed temperature 
Confirmed capacitor readings 
Unit is drain and cooling properly at this time homeowner plans to do once a year maintenance visits 

Solution:
Flushed and clean drain line 
Install proper drain insulation 
Drain repair 
Install uv air treatment with 1 year parts and labor warranty
Corbin C.
Corbin C. Checked in
Reason for call: No cool/ water leak Summary: Completed inspection to find drain line fittings were not glued. Found proper operation from equipment. Found burnt up uv air treatment kit Inspected pan to find it in proper working order no cracks. Confirmed temperature Confirmed capacitor readings Unit is drain and cooling properly at this time homeowner plans to do once a year maintenance visits Solution: Flushed and clean drain line Install proper drain insulation Drain repair Install uv air treatment with 1 year parts and labor warranty
Largo, FL 33778
On arrival found unit not cooling due to broken blower wheel. Made client aware unit is 22 year old in poor condition. Client opted for repairs at this time. Replaced part. Start and test. Unit is cooling to the best of its ability.
On arrival found unit not cooling due to broken blower wheel. Made client aware unit is 22 year old in poor condition. Client opted for repairs at this time. Replaced part. Start and test. Unit is cooling to the best of its ability.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to broken blower wheel. Made client aware unit is 22 year old in poor condition. Client opted for repairs at this time. Replaced part. Start and test. Unit is cooling to the best of its ability.
Largo, FL 33778
Reason for call:
No cool 

Summary:
Found a weak capacitor 
Found minor water in drain pan. 
Found buzzing contactor 

Replace capacitor 
Replace contactor 
1 year parts and labor warranty on repaid only 

Flushed drain line as a courtesy. 
Drain line is not pitched perfectly could result in issues in the future. 
Unit is cooling with a 20 degree split. 
Operation has been restored.
Reason for call:
No cool 

Summary:
Found a weak capacitor 
Found minor water in drain pan. 
Found buzzing contactor 

Replace capacitor 
Replace contactor 
1 year parts and labor warranty on repaid only 

Flushed drain line as a courtesy. 
Drain line is not pitched perfectly could result in issues in the future. 
Unit is cooling with a 20 degree split. 
Operation has been restored.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: Found a weak capacitor Found minor water in drain pan. Found buzzing contactor Replace capacitor Replace contactor 1 year parts and labor warranty on repaid only Flushed drain line as a courtesy. Drain line is not pitched perfectly could result in issues in the future. Unit is cooling with a 20 degree split. Operation has been restored.
Largo, FL 33778
Reason for call:
Ducts sweating unit sweating

Summary:
Completed inspection to find a ventilation issue inside the attic space. 
Found horizontal air handler, sweating, creating water inside secondary pan. 
Found a couple ducts sweating
Found multiple vent covers on second floor sweating.

Solutions: 
Primary option
Encapsulate attic with spray foam (attic queen) 
Install dehumidifier (Airbros) roughly 7k 
Will improve efficiency of building 
Will save electricity 
Will add value to building 
Will solve issue 100% 

Secondary option
Install new soffits (other contractor)
Install attic fans (other contractor) 
Aiming to improve ventilation 
May lead to more repairs
Reason for call:
Ducts sweating unit sweating

Summary:
Completed inspection to find a ventilation issue inside the attic space. 
Found horizontal air handler, sweating, creating water inside secondary pan. 
Found a couple ducts sweating
Found multiple vent covers on second floor sweating.

Solutions: 
Primary option
Encapsulate attic with spray foam (attic queen) 
Install dehumidifier (Airbros) roughly 7k 
Will improve efficiency of building 
Will save electricity 
Will add value to building 
Will solve issue 100% 

Secondary option
Install new soffits (other contractor)
Install attic fans (other contractor) 
Aiming to improve ventilation 
May lead to more repairs
Corbin C.
Corbin C. Checked in
Reason for call: Ducts sweating unit sweating Summary: Completed inspection to find a ventilation issue inside the attic space. Found horizontal air handler, sweating, creating water inside secondary pan. Found a couple ducts sweating Found multiple vent covers on second floor sweating. Solutions: Primary option Encapsulate attic with spray foam (attic queen) Install dehumidifier (Airbros) roughly 7k Will improve efficiency of building Will save electricity Will add value to building Will solve issue 100% Secondary option Install new soffits (other contractor) Install attic fans (other contractor) Aiming to improve ventilation May lead to more repairs
Largo, FL 33770
Reason for call:
No cool 

Summary:
On arrival unit turned on And was cooling. 
Completed diagnostic to find refrigerant pressures were slightly low.
Confirmed, proper capacitor readings
Confirmed a dry float switch
Confirm drain line was draining properly
Unit was running and parts were within proper amp draws. 
Found no issue with the equipment, other than the slightly low charge.
Added 2 pounds of refrigerant to bring this within specifications. Unit is cooling better than it was when I arrived.

Homeowners are looking for one time service in the future
Reason for call:
No cool 

Summary:
On arrival unit turned on And was cooling. 
Completed diagnostic to find refrigerant pressures were slightly low.
Confirmed, proper capacitor readings
Confirmed a dry float switch
Confirm drain line was draining properly
Unit was running and parts were within proper amp draws. 
Found no issue with the equipment, other than the slightly low charge.
Added 2 pounds of refrigerant to bring this within specifications. Unit is cooling better than it was when I arrived.

Homeowners are looking for one time service in the future
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: On arrival unit turned on And was cooling. Completed diagnostic to find refrigerant pressures were slightly low. Confirmed, proper capacitor readings Confirmed a dry float switch Confirm drain line was draining properly Unit was running and parts were within proper amp draws. Found no issue with the equipment, other than the slightly low charge. Added 2 pounds of refrigerant to bring this within specifications. Unit is cooling better than it was when I arrived. Homeowners are looking for one time service in the future
Largo, FL 33773
Upon arrival, the homeowner stated that a home inspector had mentioned the system’s temperature performance was outside of a healthy range. The homeowner typically keeps the thermostat set to 77°F throughout the day and does not adjust it at night.

I performed a diagnostic by lowering the thermostat to 72°F and allowing the system to run. At the plenum, I measured a 22°F temperature split, which is within the manufacturer’s recommended operating range.

Moving on to the electrical components, both blower motors, the compressor, and the high-voltage components were tested and are currently operating within a healthy range. No components are showing signs of excessive amperage or abnormal electrical operation at this time.

I then checked the refrigerant cycle. Based on the manufacturer’s specifications, the system is designed for a 10°F subcooling. After allowing the system to run for over 30 minutes, I measured a 10°F subcooling at the condenser, indicating that the refrigerant charge
Upon arrival, the homeowner stated that a home inspector had mentioned the system’s temperature performance was outside of a healthy range. The homeowner typically keeps the thermostat set to 77°F throughout the day and does not adjust it at night.

I performed a diagnostic by lowering the thermostat to 72°F and allowing the system to run. At the plenum, I measured a 22°F temperature split, which is within the manufacturer’s recommended operating range.

Moving on to the electrical components, both blower motors, the compressor, and the high-voltage components were tested and are currently operating within a healthy range. No components are showing signs of excessive amperage or abnormal electrical operation at this time.

I then checked the refrigerant cycle. Based on the manufacturer’s specifications, the system is designed for a 10°F subcooling. After allowing the system to run for over 30 minutes, I measured a 10°F subcooling at the condenser, indicating that the refrigerant charge
Ace m.
Ace m. Checked in
Upon arrival, the homeowner stated that a home inspector had mentioned the system’s temperature performance was outside of a healthy range. The homeowner typically keeps the thermostat set to 77°F throughout the day and does not adjust it at night. I performed a diagnostic by lowering the thermostat to 72°F and allowing the system to run. At the plenum, I measured a 22°F temperature split, which is within the manufacturer’s recommended operating range. Moving on to the electrical components, both blower motors, the compressor, and the high-voltage components were tested and are currently operating within a healthy range. No components are showing signs of excessive amperage or abnormal electrical operation at this time. I then checked the refrigerant cycle. Based on the manufacturer’s specifications, the system is designed for a 10°F subcooling. After allowing the system to run for over 30 minutes, I measured a 10°F subcooling at the condenser, indicating that the refrigerant charge
Largo, FL 33771
Replaced warranty blower motor on smaller system. 
$100 warranty fee
Replaced warranty blower motor on smaller system. 
$100 warranty fee
Michael A.
Michael A. Checked in
Replaced warranty blower motor on smaller system. $100 warranty fee
Largo, FL 33777
Performed maintenance on 1 system. Rinsed condenser coils. Found worn and buzzing contactor. Drain under foundation has deteriorated causing water to leak into  garage. Disconnect at condenser has loose connections and not making good contact. Cleared drain to the best of my ability. Unit is 2011. Made client aware of findings.
Performed maintenance on 1 system. Rinsed condenser coils. Found worn and buzzing contactor. Drain under foundation has deteriorated causing water to leak into  garage. Disconnect at condenser has loose connections and not making good contact. Cleared drain to the best of my ability. Unit is 2011. Made client aware of findings.
Justin G.
Justin G. Checked in
Performed maintenance on 1 system. Rinsed condenser coils. Found worn and buzzing contactor. Drain under foundation has deteriorated causing water to leak into garage. Disconnect at condenser has loose connections and not making good contact. Cleared drain to the best of my ability. Unit is 2011. Made client aware of findings.
Largo, FL 33778
Largo, FL - Mother in law suite system down due to bad indoor blower motor. 
Returning tomorrow morning to replace motor. 
No charge for repair. 
$95 service fee for today’s diagnosis
Michael A.
Michael A. Checked in
Mother in law suite system down due to bad indoor blower motor. Returning tomorrow morning to replace motor. No charge for repair. $95 service fee for today’s diagnosis