Expert Cooling, Heating and Electrical In Tarpon Springs, FL
Air Bros is proud to provide expert cooling, heating, indoor air quality and electrical services in Tarpon Springs, FL. With 24 hour availability and licensed and trained technicians on call, you can trust our impeccable work from start to finish.
We invite you to read our reviews below and find out why your neighbors consider us to be their nearby heating and air company and local electrician in Tarpon Springs, FL.
Recent Jobs and Reviews in Tarpon Springs, FL
Tarpon Springs, FL at a glance
Air Bros Air Conditioning & Electrical has completed 12 jobs in Tarpon Springs, FL between June 2025 and October 2026.
The most recent job was on October 7, 2026.
Air Bros Air Conditioning & Electrical has completed 11 jobs in Tarpon Springs, FL in the last 12 months. The first job there was in June 2025.
Job Locations and Reviews
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Blower compartment is full of bacterial growth.Verified safety float switch functionality. Safety float switch does not work. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 26° temperature split at this time. Cannot check pressures at this time because it is pouring rain. Found condenser disconnect is a safety hazard as it is broken. Sending quote per clients request for disconnect replacement, safety float switch replacement, blower assembly pull and clean, and installation of UV system. Inspected duct work and found duct work is not strapped up or sealed properly. Client is interested in replacing all duct work due to bacterial growth and condition of duct work in the attic. If client would like a quote to
Reason for call: No cool Summary: On arrival found compressor not kicking on. Confirmed compressor was getting proper voltage. Confirmed capacitor was properly charged. Found inner windings shot on compressor. (See video) Compressor needs to be replaced at this time. Part will be covered under parts warranty. Solution: Sold repair for Monday arrival time 8-10 am.
5 Ton 15.2 SEER Heat Pump 2 stage cooling RUUD system ~ 10 Year parts warranty ~ 3 year Labor warranty ** Cash price (5% off)= $10,925** ______ - Installation of Horizontal air handler in attic - New secondary safety pan - Seal plenums to unit - 5 kw back up heat element - Program existing thermostat - New safety float switches - New insulation on copper - Strap up drain line for proper pitch - Replace breakers as needed - Flush and test existing condensate drain line - Seal one supply duct to supply plenum (existing duct) ______ - Installation of Condenser unit - Flush existing refrigerant lines - Replace breakers as needed - New 4” hurricane concrete pad - New Hurricane straps - New UV rated insulation on copper - New filter line dryer - Refrigerant locking caps - Vacuum system to 500 microns - Charge system with refrigerant to proper pressures - Completed to code 100% satisfaction
System #1: Client states system has always has water issues. Upon my inspection, found system cooling with a poor 13° temperature split. Evaporator coils are severely corroded and dirty. Air filters in 3 bedrooms are severely dirty. Primary drain pan is blocked up with gunk. Blower speed is set to the highest setting. System pressures indicate very low on refrigerant Found refrigerant leak at the condenser suction line connection. All of these issues combined are causing water issues and cooling issues. System as a whole is in poor condition. Providing quotes for repairs with no guarantee and for full system replacement with warranties. Client also has concerns with the laundry room not getting adequate air flow. We will need to address this issue upon completion of repairs or full system replacement.
Reason for call: No cool Equipment: 2015 3 ton Goodman Vertical in garage Condenser on left side of home Summary: Found compressor dead on arrival confirmed proper voltage to compressor, confirmed proper readings at capacitor. Tried to wire in hard start kit. Compressor still failed to start up. Solution: Recommended system replacement due to compressor being a very expensive repair outside of warranty.
Found water and safety switch and extreme growth inside drain line flushed and clean drain line put drain solution in pan and drain line left tablets and pan to prevent backup in the future. Confirmed proper operation of equipment in all aspects.
Reason for call: Second opinion Summary: There were no issues at the System the float switch wasn't pitched properly adjusted pitch did full inspection. operation of equipment is phenomenal. Changed all filters inside home built value with client. Client signed up on membership.
Reason for call: No cool Equipment: 2016 trane 2.5 ton Vertical in front closet Condenser on right side of home Summary: On arrival found drain line clogged and thermostat shut off. Confirmed proper operation of equipment. 20 degree split. Proper amp draws. Proper cap readings. Solution: Flushed drain line and proper drainage was restored.
Find My inspection, found upstairs system is 20 years old and has a bad capacitor and low on refrigerant. Replaced capacitor and added 3 pounds of refrigerant. System had a 10° split and now has a 16 to 18° temperature split. Pressures after adding refrigerant are now indicating that there might be a metering device issue. Let the tenant know since the tenant was paying for the repairs today that the system is not in great condition and to not expect a whole lot out of it. Client needs to change filters asap. System is cooling the best it can at this time.
Reason for call: No cool Equipment: 2019 grand aire 3.5 ton heat pump Horizontal in garage 12-15ft elevated Condenser on platform right of home Summary: On arrival found failed blower motor and frozen evaporator and frozen suction. Confirmed motor had power and call for fan. Confirmed cap readings, uv treatment is install. Solution Replace air handler blower motor Add transformer to uv treatment Restored operation to equipment signed homeowner up on membership plan.
Tenant states system does not cool well during the day, Thermostat is hard to function, and filter does not stay in. Upon my inspection, found system is cooling with only a 12° temperature split. Evaporator coils are very dirty. The filter access is not easy to use. Checked pressures and found that the system has a restriction on the TXV. Client is aware that evaporator coil is at risk of freezing due to low saturation temperature. Air handler is a 2003 and condenser is a 2024. It is likely that the condenser was only replaced because of the hurricane damage. Systems are not matching. Will provide quote for TXV replacement if it is available. Providing quote and highly recommending full system replacement
noise complaint Upon arrival, homeowner explained that they just noticed this morning that when the condensing unit turned on, it made a very loud noise. Upon initial inspection when condenser started I did hear that it was loud but not unusual. In rush amp draw measured 64 out of total allowed 124 A. Found system was low on refrigerant. Recommended leak search. Homeowner declined and just wants to add refrigerant at this time. Added 2 pounds of R410 a to the system. Advised homeowner to keep an eye on how everything is running over the next month or so as there is no way to know how fast or slow slowly, the refrigerant will leak out again. signed up for maintenance membership