Instant Quote Shop Filters Call Air Bros

St. Petersburg, FL

air-bros-team-with-truck

The Best AC Repair in St. Petersburg, FL — From Technicians Your Neighbors Already Trust

When your AC quits in the middle of a St. Pete summer, you don't want a stranger in an unmarked van. You want a technician your neighbors already know and trust. Air Bros Air Conditioning & Electrical has been fixing air conditioners in St. Petersburg since 2020, but our roots run deeper — founder Ricky Orta grew up learning the trade from his father and has been a licensed HVAC contractor since 2006. That local, hands-on experience is why homeowners from Historic Kenwood to Snell Isle call us the best AC repair company in St. Petersburg.

We're headquartered right here in the Shore Acres neighborhood, so when you call, you're not routed to a call center — you're talking to the same local team that services your street.

Call us at 727-217-6148 or contact us online today for all of your HVAC, indoor air quality and electrical needs.

Meet the technicians who service St. Petersburg

What to expect when we show up

Calling a repair company you've never used before shouldn't feel like a gamble. Here's exactly how an Air Bros service call goes, every time.

You'll get a heads-up before we arrive, then a uniformed technician in a marked Air Bros vehicle shows up in the window we promised. We diagnose the whole system — not just the obvious symptom — then explain what we found and what your options are before any work starts. You approve the price up front, we make the repair, and we don't leave until we've confirmed the system is cooling the way it should.

Every technician is a background-checked, drug-tested Air Bros employee — never a subcontractor — and each one is trained to service every major AC and heat pump brand. It's the kind of consistency you can only get from a local team that answers to its own name.

And if something isn't right? Our 100% satisfaction guarantee means we make it right.

Signs you need AC repair

St. Petersburg's heat and humidity push air conditioners harder than almost anywhere else in the country. Call for AC repair if you notice:

  • Warm air blowing from vents, or the system running constantly without cooling
  • Water pooling around your air handler (a common issue in St. Pete's older homes with attic-run drain lines)
  • Musty odors or visible mold near vents — a sign of a clogged condensate line or dirty coil
  • Rising humidity indoors despite the AC running
  • Short cycling, tripped breakers, or a system that won't turn on at all

Our technicians diagnose the full system on every call — refrigerant charge, temperature split, electrical connections, and drain line — so you get a real fix, not a temporary patch.

Comprehensive HVAC Services in St. Petersburg

We offer a full range of heating and cooling services to keep your St. Petersburg, FL, home comfortable year-round:

  • Air Conditioning: From AC repair and AC installation to routine maintenance, we ensure your cooling system keeps you comfortable during those hot Florida summers. We offer same-day service for AC emergencies, so you never have to suffer in the heat.
  • Heating: Stay warm and cozy in the winter with our comprehensive heating services. We repair and install all types of heating systems, including furnaces and heat pumps, and offer preventative maintenance to keep your system running efficiently.
  • Indoor Air Quality: Improve your indoor air quality with our dehumidifier and UV light installation services. We'll help you control excess humidity and eliminate airborne contaminants, creating a healthier home environment.
  • Ductwork: Ensure optimal airflow and energy efficiency with our ductwork repair and installation services. We can address leaks and damage, and design a system that's perfect for your home.
  • Pool Heater Services: Extend your swim season with our pool heater installation and repair services.
  • Electrical Services: From outlet and switch replacements to ceiling fan installations to whole-house surge protector installations, we have the experts to handle your electrical service needs.

Our experienced technicians are skilled in all aspects of HVAC service and are dedicated to providing top-quality workmanship and customer care.

Why Choose Air Bros?

  • Local Expertise: We understand the unique climate challenges of St. Petersburg.
  • Fast and Reliable Service: We offer same-day service for AC emergencies and prioritize prompt service for all your HVAC needs.
  • Experienced Technicians: Our team is highly trained and experienced in all aspects of HVAC service.
  • Upfront Pricing: We provide transparent pricing with no hidden costs.
  • Customer Satisfaction Guaranteed: Your comfort and satisfaction are our top priorities.

Contact Air Bros Today!

Whether you need emergency AC repair, a new heating system installation, or any other HVAC service, Air Bros is here to help. Contact us today for a free consultation or to schedule a service appointment. We're proud to be your trusted HVAC partner in St. Petersburg!

Call us at 727-217-6148 or contact us online today!

Recent Jobs and Reviews in St. Petersburg, FL

St. Petersburg, FL at a glance

Air Bros Air Conditioning & Electrical has completed 25 jobs in St. Petersburg, FL in August 2025.

The most recent job was on August 18, 2025.

Air Bros Air Conditioning & Electrical has completed 1,919 jobs in St. Petersburg, FL in the last 12 months. The first job there was in December 2024.

Job Locations and Reviews

Ricky O.
Ricky O. Checked in
Found unit not cooling due to low volt short blown fuse. I checked for shorts with popper none found. Replaced fuse. Unit has been cooling for 30min no issues. Inspected low volt wiring in attic no issues. Quoting new ducts
St. Petersburg, FL 33703
Griffin K.
Griffin K. Checked in
Missing a leg of power from the utility company called them said they would be out by 7:00 pm to fix it
St. Petersburg, FL 33703
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to power switch being turned off. Turned on and checked unit. Unit is cooling at this time.
St. Petersburg, FL 33711
On arrival found unit not cooling due to bad condenser fan motor. Client wanted to hold off on repairs at this time to make decision on repair and replacement options. Made client aware of age and condition of unit. Condenser was submerged in contaminated flood water from previous storms. Will submit estimates for repairs and replacement options. Unit is not cooling.
On arrival found unit not cooling due to bad condenser fan motor. Client wanted to hold off on repairs at this time to make decision on repair and replacement options. Made client aware of age and condition of unit. Condenser was submerged in contaminated flood water from previous storms. Will submit estimates for repairs and replacement options. Unit is not cooling.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to bad condenser fan motor. Client wanted to hold off on repairs at this time to make decision on repair and replacement options. Made client aware of age and condition of unit. Condenser was submerged in contaminated flood water from previous storms. Will submit estimates for repairs and replacement options. Unit is not cooling.
St. Petersburg, FL 33702
Ricky O.
Ricky O. Checked in
Found system leaking water due to clogged drain. I cleaned drain line and verified unit is draining for now with no issues. Also checked refrigerant charge, no issues. I did find a small crack in pan but as long as water level stays down, it will not be issue. Told client to keep eye on it. Diagnostic
St. Petersburg, FL 33712
Justin G.
Justin G. Checked in
On arrival found clogged drain. Cleared pan and drain. Added chemical to help prevent growth. Will return to perform maintenance on 2 systems and clean mini split blower wheel.
St. Petersburg, FL 33703
St. Petersburg, FL - Arrived onsite and found unit flat on refrigerant. Could see oil on suction line near compressor. Found high voltage arc on line that popped a hole. I welded hole and recharged system. Advised client that condenser fan motor sounds rough and may be next.
Ricky O.
Ricky O. Checked in
Arrived onsite and found unit flat on refrigerant. Could see oil on suction line near compressor. Found high voltage arc on line that popped a hole. I welded hole and recharged system. Advised client that condenser fan motor sounds rough and may be next.
St. Petersburg, FL 33713
Justin G.
Justin G. Checked in
On arrival found unit leaking water due to clogged drain and float switch being turned up. Cleared pan and drain. Added chemical to help prevent growth. Vacuumed return box. Set fan to run continuously for 3 days to help dry return box. No filter on unit at this time. Recommend to install one soon. Unit operating properly at this time.
St. Petersburg, FL 33713
2.5 ton straight cool system
Paid with credit card upon completion
New vertical air handler
New breakered heater
New thermostat
New 2ft of drain line with p trap
New air handler stand with filter rack
New condenser unit on roof
New hurricane straps
New absorption pads
New liquid line filter dryer
New UV insulation (1 stick)
2.5 ton straight cool system
Paid with credit card upon completion
New vertical air handler
New breakered heater
New thermostat
New 2ft of drain line with p trap
New air handler stand with filter rack
New condenser unit on roof
New hurricane straps
New absorption pads
New liquid line filter dryer
New UV insulation (1 stick)
Kyle K.
Kyle K. Checked in
2.5 ton straight cool system Paid with credit card upon completion New vertical air handler New breakered heater New thermostat New 2ft of drain line with p trap New air handler stand with filter rack New condenser unit on roof New hurricane straps New absorption pads New liquid line filter dryer New UV insulation (1 stick)
St. Petersburg, FL 33715
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to tripped float switch. Cleared drain and pan. Added chemical to help prevent growth. Flushed with water. Unit cooling at this time.
St. Petersburg, FL 33703
Replaced outdoor motor and capacitor 

Upon letting system run suction pressure dropping drastically. Found air handler coils impacted with hair/debris. Coil fins bent/damaged. Looks as if previous company was using wire brush to clean. System is running and cooling at this time.
Replaced outdoor motor and capacitor 

Upon letting system run suction pressure dropping drastically. Found air handler coils impacted with hair/debris. Coil fins bent/damaged. Looks as if previous company was using wire brush to clean. System is running and cooling at this time.
Nathan A.
Nathan A. Checked in
Replaced outdoor motor and capacitor Upon letting system run suction pressure dropping drastically. Found air handler coils impacted with hair/debris. Coil fins bent/damaged. Looks as if previous company was using wire brush to clean. System is running and cooling at this time.
St. Petersburg, FL 33703
Replace evaporator coil, txv and recharge system with freon
Cleaned and treated drain line.
Replace evaporator coil, txv and recharge system with freon
Cleaned and treated drain line.
Michael A.
Michael A. Checked in
Replace evaporator coil, txv and recharge system with freon Cleaned and treated drain line.
St. Petersburg, FL 33713
Ruud 18 SEER2 heat pump 5 ton split system with 5kw heater
Miami dade pad and stand
Media filter
Coffin box with legs
Extend ducts
New drain
Ruud thermostat
10 year parts warranty 
3 year labor warranty 
Tax labor and permit included
Ruud 18 SEER2 heat pump 5 ton split system with 5kw heater
Miami dade pad and stand
Media filter
Coffin box with legs
Extend ducts
New drain
Ruud thermostat
10 year parts warranty 
3 year labor warranty 
Tax labor and permit included
Justin G.
Justin G. Checked in
Ruud 18 SEER2 heat pump 5 ton split system with 5kw heater Miami dade pad and stand Media filter Coffin box with legs Extend ducts New drain Ruud thermostat 10 year parts warranty 3 year labor warranty Tax labor and permit included
St. Petersburg, FL 33705
Ricky O.
Ricky O. Checked in
1) remove and clean blower wheel 2) pull and clean evaporator coil 3) replace refrigerant if needed. I'm assuming it does if coil gets removed.
St. Petersburg, FL 33703
Griffin K.
Griffin K. Checked in
Replace bad breaker feeding the range
St. Petersburg, FL 33702
Upon arrival home owner states unit was intermittently cooling. Found outdoor fan motor not spinning. Motor caused fan side of capacitor to fail. Replaced capacitor and unit began to run. Motor pulling high amps. Explained that we should replace motor if happens again. Recommendations still from previous visit. Home owner would like estimates for a new system and possible relocation. Unit is currently cooling but explained I can not guarantee for how long.
Upon arrival home owner states unit was intermittently cooling. Found outdoor fan motor not spinning. Motor caused fan side of capacitor to fail. Replaced capacitor and unit began to run. Motor pulling high amps. Explained that we should replace motor if happens again. Recommendations still from previous visit. Home owner would like estimates for a new system and possible relocation. Unit is currently cooling but explained I can not guarantee for how long.
Nathan A.
Nathan A. Checked in
Upon arrival home owner states unit was intermittently cooling. Found outdoor fan motor not spinning. Motor caused fan side of capacitor to fail. Replaced capacitor and unit began to run. Motor pulling high amps. Explained that we should replace motor if happens again. Recommendations still from previous visit. Home owner would like estimates for a new system and possible relocation. Unit is currently cooling but explained I can not guarantee for how long.
St. Petersburg, FL 33702
First Maitenence
Re insulated 1ft of drain line pvc to prevent sweating. 
System is cooling with proper temperatures, pressures, and amp draws. Capacitor is reading within factory specs. Cleaned condenser coils. Cleaned and treated drain line and primary drain pan. System is cooling at this time.
First Maitenence
Re insulated 1ft of drain line pvc to prevent sweating. 
System is cooling with proper temperatures, pressures, and amp draws. Capacitor is reading within factory specs. Cleaned condenser coils. Cleaned and treated drain line and primary drain pan. System is cooling at this time.
Michael A.
Michael A. Checked in
First Maitenence Re insulated 1ft of drain line pvc to prevent sweating. System is cooling with proper temperatures, pressures, and amp draws. Capacitor is reading within factory specs. Cleaned condenser coils. Cleaned and treated drain line and primary drain pan. System is cooling at this time.
St. Petersburg, FL 33709
Justin G.
Justin G. Checked in
Clean evap coil in place. Remove and replace auxiliary pan below unit due to rust. Tax and labor included.
St. Petersburg, FL 33701
Upon my inspection, I found system running good with a 20° temp split, good amp draws on the compressor and fan motor. Capacitor is within factory specs. Contactar is in good working order. Recommended condenser coil cleaning to help with efficiency and performed a deep chemical condenser coil cleaning. After cleaning coils, pressures indicated that the system was about a pound low on refrigerant. I added a pound and got the subcool to factory rated spec. Cleaned and treated drain line complimentary. System is cooling properly at this time. 

Recommendations:
- Fix or install new attic fan 
- New insulation in attic

Down stairs unit: 
- Duct work is leaking significantly and client stated duct work is about 26 years old. 
- Improper duct work was installed (silver duct) instead of black mobile home duct. 

Recommendations: 
- Install new mobile home duct work with all new sealed connections. 
- inspect and possibly repair existing duct work.
Upon my inspection, I found system running good with a 20° temp split, good amp draws on the compressor and fan motor. Capacitor is within factory specs. Contactar is in good working order. Recommended condenser coil cleaning to help with efficiency and performed a deep chemical condenser coil cleaning. After cleaning coils, pressures indicated that the system was about a pound low on refrigerant. I added a pound and got the subcool to factory rated spec. Cleaned and treated drain line complimentary. System is cooling properly at this time. 

Recommendations:
- Fix or install new attic fan 
- New insulation in attic

Down stairs unit: 
- Duct work is leaking significantly and client stated duct work is about 26 years old. 
- Improper duct work was installed (silver duct) instead of black mobile home duct. 

Recommendations: 
- Install new mobile home duct work with all new sealed connections. 
- inspect and possibly repair existing duct work.
Michael A.
Michael A. Checked in
Upon my inspection, I found system running good with a 20° temp split, good amp draws on the compressor and fan motor. Capacitor is within factory specs. Contactar is in good working order. Recommended condenser coil cleaning to help with efficiency and performed a deep chemical condenser coil cleaning. After cleaning coils, pressures indicated that the system was about a pound low on refrigerant. I added a pound and got the subcool to factory rated spec. Cleaned and treated drain line complimentary. System is cooling properly at this time. Recommendations: - Fix or install new attic fan - New insulation in attic Down stairs unit: - Duct work is leaking significantly and client stated duct work is about 26 years old. - Improper duct work was installed (silver duct) instead of black mobile home duct. Recommendations: - Install new mobile home duct work with all new sealed connections. - inspect and possibly repair existing duct work.
St. Petersburg, FL 33701
Found bad capacitor as main issue with system not cooling. Al o found a severely dirty filter. Recommended to replace filter. Replaced capacitor and recommended drain line and condensate pump cleaning. Cleaned drain line and condensate pump as well as a chemical treatment. Cleaned up closet that air handler was in. Rinsed condenser coils complimentary. System is cooling however it should be noted that the compressor amp draw is reaching its maximum rated amps indicating that it could potentially fail or keep wearing out capacitors prematurely. System is cooling with a 20° split at this time. 

Replace filter size 16”x20”
Found bad capacitor as main issue with system not cooling. Al o found a severely dirty filter. Recommended to replace filter. Replaced capacitor and recommended drain line and condensate pump cleaning. Cleaned drain line and condensate pump as well as a chemical treatment. Cleaned up closet that air handler was in. Rinsed condenser coils complimentary. System is cooling however it should be noted that the compressor amp draw is reaching its maximum rated amps indicating that it could potentially fail or keep wearing out capacitors prematurely. System is cooling with a 20° split at this time. 

Replace filter size 16”x20”
Michael A.
Michael A. Checked in
Found bad capacitor as main issue with system not cooling. Al o found a severely dirty filter. Recommended to replace filter. Replaced capacitor and recommended drain line and condensate pump cleaning. Cleaned drain line and condensate pump as well as a chemical treatment. Cleaned up closet that air handler was in. Rinsed condenser coils complimentary. System is cooling however it should be noted that the compressor amp draw is reaching its maximum rated amps indicating that it could potentially fail or keep wearing out capacitors prematurely. System is cooling with a 20° split at this time. Replace filter size 16”x20”
St. Petersburg, FL 33713
Diagnosed a bad evaporator blower motor. Replaced motor. System is cooling properly now with good pressures and sub cooling. System has a 20° split. Cleaned blower motor housing and blower wheel as well as the wires and inside the air handler. Installed new filter in air handler. 
Amp draw on the compressor is getting close to its max rating but it is working properly. Amp draw on condenser fan motor is good. 
System is cooling properly at this time.
Diagnosed a bad evaporator blower motor. Replaced motor. System is cooling properly now with good pressures and sub cooling. System has a 20° split. Cleaned blower motor housing and blower wheel as well as the wires and inside the air handler. Installed new filter in air handler. 
Amp draw on the compressor is getting close to its max rating but it is working properly. Amp draw on condenser fan motor is good. 
System is cooling properly at this time.
Michael A.
Michael A. Checked in
Diagnosed a bad evaporator blower motor. Replaced motor. System is cooling properly now with good pressures and sub cooling. System has a 20° split. Cleaned blower motor housing and blower wheel as well as the wires and inside the air handler. Installed new filter in air handler. Amp draw on the compressor is getting close to its max rating but it is working properly. Amp draw on condenser fan motor is good. System is cooling properly at this time.
St. Petersburg, FL 33710
Mitsubishi Mini split
10 year parts warranty
3 year labor warranty
-Electric run high voltage
-2 pole breaker
-2 ton system
-Condenser on hurricane pad by window
-Drain line
-Line cover sealed
-Comm wire
-Insulated refrigerant lines
Mitsubishi Mini split
10 year parts warranty
3 year labor warranty
-Electric run high voltage
-2 pole breaker
-2 ton system
-Condenser on hurricane pad by window
-Drain line
-Line cover sealed
-Comm wire
-Insulated refrigerant lines
Martin W.
Martin W. Checked in
Mitsubishi Mini split 10 year parts warranty 3 year labor warranty -Electric run high voltage -2 pole breaker -2 ton system -Condenser on hurricane pad by window -Drain line -Line cover sealed -Comm wire -Insulated refrigerant lines
St. Petersburg, FL 33705
Justin G.
Justin G. Checked in
On arrival found unit leaking water due to clogged drain. Cleared pan and drain. Added chemical to help prevent growth. Found insulation in ooor condition and should be re insulated to prevent sweating. Motor amp are good but motor is noises. Possible failure in future. Advised tenant to watch for next 48 hours before putting ceiling tile back up. Both filters need to be changed. 1-18x18x1 1-12x24x1 this filter must be cut to fit properly.
St. Petersburg, FL 33701
Justin G.
Justin G. Checked in
Install new pump. Connect float switch. Run new drain to pump. Tax and labor included. Complimentary cleaned coil in place. Unit draining properly.
St. Petersburg, FL 33703
ADU Visit 

Upon arrival tenant stated unit is not running at all. Found drain line backed up into safety switch causing system to shut off. Recommend replacing drain line due to several visits. Cleared drain line and verified drainage. Found capacitor very weak. Replaced capacitor. After repairs, system began to run. Found system 1lb low of 410a. Explained to home owner to keep and eye on system. If issue happens again we will need to do a leak search. System is currently cooling and draining.
ADU Visit 

Upon arrival tenant stated unit is not running at all. Found drain line backed up into safety switch causing system to shut off. Recommend replacing drain line due to several visits. Cleared drain line and verified drainage. Found capacitor very weak. Replaced capacitor. After repairs, system began to run. Found system 1lb low of 410a. Explained to home owner to keep and eye on system. If issue happens again we will need to do a leak search. System is currently cooling and draining.
Nathan A.
Nathan A. Checked in
ADU Visit Upon arrival tenant stated unit is not running at all. Found drain line backed up into safety switch causing system to shut off. Recommend replacing drain line due to several visits. Cleared drain line and verified drainage. Found capacitor very weak. Replaced capacitor. After repairs, system began to run. Found system 1lb low of 410a. Explained to home owner to keep and eye on system. If issue happens again we will need to do a leak search. System is currently cooling and draining.
St. Petersburg, FL 33713
How do I know if my AC needs repair or full replacement?

Our technicians inspect the full system — age, refrigerant type, corrosion, and repair history — and give you an honest recommendation. If a repair makes sense, we'll fix it. If the unit is beyond its useful life, we'll walk you through replacement options with no pressure.

Are your technicians background-checked and licensed?

Yes. Every Air Bros technician is background-checked, factory-trained, and works under our state HVAC license (#CAC1820499) and electrical license (#EC13015085).

What parts of St. Petersburg do you serve?

We serve all of St. Petersburg, including Downtown, Historic Kenwood, Old Northeast, Snell Isle, Crescent Lake, Shore Acres, and Coquina Key, plus Seminole, Largo, Pinellas Park, and the surrounding beach communities.

Do you offer same-day AC repair in St. Petersburg?

Yes. We offer 24/7 emergency AC repair with same-day service throughout St. Petersburg and the surrounding Pinellas County area.

Is Air Bros a local St. Petersburg company, or a franchise?

Air Bros is 100% locally owned and operated, headquartered in the Shore Acres neighborhood of St. Petersburg. We're not a franchise — every technician is a direct employee, not a subcontractor.

Contact the Bros You Know Today!

Gravity Forms Pagination Must be Steps