Instant Quote Shop Filters Call Air Bros

St. Petersburg, FL

air-bros-team-with-truck

The Best AC Repair in St. Petersburg, FL — From Technicians Your Neighbors Already Trust

When your AC quits in the middle of a St. Pete summer, you don't want a stranger in an unmarked van. You want a technician your neighbors already know and trust. Air Bros Air Conditioning & Electrical has been fixing air conditioners in St. Petersburg since 2020, but our roots run deeper — founder Ricky Orta grew up learning the trade from his father and has been a licensed HVAC contractor since 2006. That local, hands-on experience is why homeowners from Historic Kenwood to Snell Isle call us the best AC repair company in St. Petersburg.

We're headquartered right here in the Shore Acres neighborhood, so when you call, you're not routed to a call center — you're talking to the same local team that services your street.

Call us at 727-217-6148 or contact us online today for all of your HVAC, indoor air quality and electrical needs.

Meet the technicians who service St. Petersburg

What to expect when we show up

Calling a repair company you've never used before shouldn't feel like a gamble. Here's exactly how an Air Bros service call goes, every time.

You'll get a heads-up before we arrive, then a uniformed technician in a marked Air Bros vehicle shows up in the window we promised. We diagnose the whole system — not just the obvious symptom — then explain what we found and what your options are before any work starts. You approve the price up front, we make the repair, and we don't leave until we've confirmed the system is cooling the way it should.

Every technician is a background-checked, drug-tested Air Bros employee — never a subcontractor — and each one is trained to service every major AC and heat pump brand. It's the kind of consistency you can only get from a local team that answers to its own name.

And if something isn't right? Our 100% satisfaction guarantee means we make it right.

Signs you need AC repair

St. Petersburg's heat and humidity push air conditioners harder than almost anywhere else in the country. Call for AC repair if you notice:

  • Warm air blowing from vents, or the system running constantly without cooling
  • Water pooling around your air handler (a common issue in St. Pete's older homes with attic-run drain lines)
  • Musty odors or visible mold near vents — a sign of a clogged condensate line or dirty coil
  • Rising humidity indoors despite the AC running
  • Short cycling, tripped breakers, or a system that won't turn on at all

Our technicians diagnose the full system on every call — refrigerant charge, temperature split, electrical connections, and drain line — so you get a real fix, not a temporary patch.

Comprehensive HVAC Services in St. Petersburg

We offer a full range of heating and cooling services to keep your St. Petersburg, FL, home comfortable year-round:

  • Air Conditioning: From AC repair and AC installation to routine maintenance, we ensure your cooling system keeps you comfortable during those hot Florida summers. We offer same-day service for AC emergencies, so you never have to suffer in the heat.
  • Heating: Stay warm and cozy in the winter with our comprehensive heating services. We repair and install all types of heating systems, including furnaces and heat pumps, and offer preventative maintenance to keep your system running efficiently.
  • Indoor Air Quality: Improve your indoor air quality with our dehumidifier and UV light installation services. We'll help you control excess humidity and eliminate airborne contaminants, creating a healthier home environment.
  • Ductwork: Ensure optimal airflow and energy efficiency with our ductwork repair and installation services. We can address leaks and damage, and design a system that's perfect for your home.
  • Pool Heater Services: Extend your swim season with our pool heater installation and repair services.
  • Electrical Services: From outlet and switch replacements to ceiling fan installations to whole-house surge protector installations, we have the experts to handle your electrical service needs.

Our experienced technicians are skilled in all aspects of HVAC service and are dedicated to providing top-quality workmanship and customer care.

Why Choose Air Bros?

  • Local Expertise: We understand the unique climate challenges of St. Petersburg.
  • Fast and Reliable Service: We offer same-day service for AC emergencies and prioritize prompt service for all your HVAC needs.
  • Experienced Technicians: Our team is highly trained and experienced in all aspects of HVAC service.
  • Upfront Pricing: We provide transparent pricing with no hidden costs.
  • Customer Satisfaction Guaranteed: Your comfort and satisfaction are our top priorities.

Contact Air Bros Today!

Whether you need emergency AC repair, a new heating system installation, or any other HVAC service, Air Bros is here to help. Contact us today for a free consultation or to schedule a service appointment. We're proud to be your trusted HVAC partner in St. Petersburg!

Call us at 727-217-6148 or contact us online today!

Recent Jobs and Reviews in St. Petersburg, FL

St. Petersburg, FL at a glance

Air Bros Air Conditioning & Electrical has completed 25 jobs in St. Petersburg, FL in August 2025.

The most recent job was on August 30, 2025.

Air Bros Air Conditioning & Electrical has completed 1,919 jobs in St. Petersburg, FL in the last 12 months. The first job there was in December 2024.

Job Locations and Reviews

Home owner states unit was shutting off multiple times a day. Shop vacuumed own drain line and system would only shut off every other day. Drain line clear. Found water in primary safety switch causing system to shut off. Found safety threaded fitting backed out. Tightened fitting. Checked drain pan and coils. Inspected blower wheel. Unit is currently cooling. 1 year old new build system.
Home owner states unit was shutting off multiple times a day. Shop vacuumed own drain line and system would only shut off every other day. Drain line clear. Found water in primary safety switch causing system to shut off. Found safety threaded fitting backed out. Tightened fitting. Checked drain pan and coils. Inspected blower wheel. Unit is currently cooling. 1 year old new build system.
Nathan A.
Nathan A. Checked in
Home owner states unit was shutting off multiple times a day. Shop vacuumed own drain line and system would only shut off every other day. Drain line clear. Found water in primary safety switch causing system to shut off. Found safety threaded fitting backed out. Tightened fitting. Checked drain pan and coils. Inspected blower wheel. Unit is currently cooling. 1 year old new build system.
St. Petersburg, FL 33705
On arrival found condenser breaker tripped. Inspected unit. Amp draws good. Pressures good. Found loose connection at condenser for possible cause. Unit cooling at this time.
On arrival found condenser breaker tripped. Inspected unit. Amp draws good. Pressures good. Found loose connection at condenser for possible cause. Unit cooling at this time.
Justin G.
Justin G. Checked in
On arrival found condenser breaker tripped. Inspected unit. Amp draws good. Pressures good. Found loose connection at condenser for possible cause. Unit cooling at this time.
St. Petersburg, FL 33703
Upon my inspection, found both heads to mini split were blowing warm air. Found dirty filters on one head in the main bedroom. Cleaned filters. At the condenser I found a code LP on the control board. Condenser coils are dirty and need to be cleaned. Client would like to clean themselves. Amp draws on compressor and fan motor are good. Pressures indicated system was slightly low on refrigerant possibly from install. Added 1 lb of refrigerant to establish a baseline for future reference. System is cooling at this time with a 30° temp split. 
System was half way under water from flooding. If issue continues, tech support may be needed to determine if sensors are failing.
Upon my inspection, found both heads to mini split were blowing warm air. Found dirty filters on one head in the main bedroom. Cleaned filters. At the condenser I found a code LP on the control board. Condenser coils are dirty and need to be cleaned. Client would like to clean themselves. Amp draws on compressor and fan motor are good. Pressures indicated system was slightly low on refrigerant possibly from install. Added 1 lb of refrigerant to establish a baseline for future reference. System is cooling at this time with a 30° temp split. 
System was half way under water from flooding. If issue continues, tech support may be needed to determine if sensors are failing.
Michael A.
Michael A. Checked in
Upon my inspection, found both heads to mini split were blowing warm air. Found dirty filters on one head in the main bedroom. Cleaned filters. At the condenser I found a code LP on the control board. Condenser coils are dirty and need to be cleaned. Client would like to clean themselves. Amp draws on compressor and fan motor are good. Pressures indicated system was slightly low on refrigerant possibly from install. Added 1 lb of refrigerant to establish a baseline for future reference. System is cooling at this time with a 30° temp split. System was half way under water from flooding. If issue continues, tech support may be needed to determine if sensors are failing.
St. Petersburg, FL 33703
St. Petersburg, FL - Replaced warranty coil and txv for downstairs unit.  Added refrigerant back to factory specs. Unit cooling properly at this time.
Justin G.
Justin G. Checked in
Replaced warranty coil and txv for downstairs unit. Added refrigerant back to factory specs. Unit cooling properly at this time.
St. Petersburg, FL 33713
Mini splits are not locally manufactured/parts available. Recommend replacing with brand that offers parts near by. Both units freezing over.
Mini splits are not locally manufactured/parts available. Recommend replacing with brand that offers parts near by. Both units freezing over.
Nathan A.
Nathan A. Checked in
Mini splits are not locally manufactured/parts available. Recommend replacing with brand that offers parts near by. Both units freezing over.
St. Petersburg, FL 33704
Home owner wanted someone to come out and check over ac. Says he keeps it 70° during the day. Thermostat satisfied upon arrival. Unit is currently working. New insulation but has single pain windows. Went over a few recommendations and explained he may want to start budgeting for system. Electric bill not terribly high (180$ for 800sf home). Would recommend adding primary safety switch and outdoor electrical disconnect.
Home owner wanted someone to come out and check over ac. Says he keeps it 70° during the day. Thermostat satisfied upon arrival. Unit is currently working. New insulation but has single pain windows. Went over a few recommendations and explained he may want to start budgeting for system. Electric bill not terribly high (180$ for 800sf home). Would recommend adding primary safety switch and outdoor electrical disconnect.
Nathan A.
Nathan A. Checked in
Home owner wanted someone to come out and check over ac. Says he keeps it 70° during the day. Thermostat satisfied upon arrival. Unit is currently working. New insulation but has single pain windows. Went over a few recommendations and explained he may want to start budgeting for system. Electric bill not terribly high (180$ for 800sf home). Would recommend adding primary safety switch and outdoor electrical disconnect.
St. Petersburg, FL 33702
Goodman 2.5 ton 17.5 SEER2 heat pump inverter split system with 5kw heater
Metal insulated stand
Sheet metal to cover return plenum
Hurricane pad
Anchor condenser
Digital WiFi thermostat
Primary float switch
Remove existing equipment 
Connect to existing ducts and electric 
Seal unit to code
10 year parts warranty 
3 year labor warranty 
Tax labor and permit included 
0% for 18 months financing included with price
Goodman 2.5 ton 17.5 SEER2 heat pump inverter split system with 5kw heater
Metal insulated stand
Sheet metal to cover return plenum
Hurricane pad
Anchor condenser
Digital WiFi thermostat
Primary float switch
Remove existing equipment 
Connect to existing ducts and electric 
Seal unit to code
10 year parts warranty 
3 year labor warranty 
Tax labor and permit included 
0% for 18 months financing included with price
Kyle K.
Kyle K. Checked in
Goodman 2.5 ton 17.5 SEER2 heat pump inverter split system with 5kw heater Metal insulated stand Sheet metal to cover return plenum Hurricane pad Anchor condenser Digital WiFi thermostat Primary float switch Remove existing equipment Connect to existing ducts and electric Seal unit to code 10 year parts warranty 3 year labor warranty Tax labor and permit included 0% for 18 months financing included with price
St. Petersburg, FL 33712
Justin G.
Justin G. Checked in
Inspected bath fan in bathroom for water staining on ceiling. Found line set and drain run next to vent. Client will need to cut hole in ceiling of bathroom to allow proper access next to staining. Unable to locate source of water at this time.
St. Petersburg, FL 33701
Justin G.
Justin G. Checked in
Replace 115v thermostat. Tax and labor included
St. Petersburg, FL 33701
Strapped up all existing duct work. Ensured no ducts are touching each other . Installed two uv systems total, one in each system between the evaporator coil and blower motor. Systems are both cooling at this time with the improvements made. 
Emptied dehumidifiers water tanks while I was here. 
** While strapping up duct work, I found a supply duct that has a bunch of insulation missing most likely due to rodents. Will recommend to replace single duct line and providing a quote for this job.
Strapped up all existing duct work. Ensured no ducts are touching each other . Installed two uv systems total, one in each system between the evaporator coil and blower motor. Systems are both cooling at this time with the improvements made. 
Emptied dehumidifiers water tanks while I was here. 
** While strapping up duct work, I found a supply duct that has a bunch of insulation missing most likely due to rodents. Will recommend to replace single duct line and providing a quote for this job.
Michael A.
Michael A. Checked in
Strapped up all existing duct work. Ensured no ducts are touching each other . Installed two uv systems total, one in each system between the evaporator coil and blower motor. Systems are both cooling at this time with the improvements made. Emptied dehumidifiers water tanks while I was here. ** While strapping up duct work, I found a supply duct that has a bunch of insulation missing most likely due to rodents. Will recommend to replace single duct line and providing a quote for this job.
St. Petersburg, FL 33704
Ruud 3 ton 15.3 seer2 heat pump split system with 5kw heater
Miami dade with 18” stand
Anchor condenser
Vertical
Primary float
Digital thermostat
Media filter rack with 4” filter
Clear drain
Remove existing equipment 
Connect to existing ducts and electrical 
Seal unit to code
Tax labor and permit included
10 year parts warranty 
3 year labor warranty
Ruud 3 ton 15.3 seer2 heat pump split system with 5kw heater
Miami dade with 18” stand
Anchor condenser
Vertical
Primary float
Digital thermostat
Media filter rack with 4” filter
Clear drain
Remove existing equipment 
Connect to existing ducts and electrical 
Seal unit to code
Tax labor and permit included
10 year parts warranty 
3 year labor warranty
Justin G.
Justin G. Checked in
Ruud 3 ton 15.3 seer2 heat pump split system with 5kw heater Miami dade with 18” stand Anchor condenser Vertical Primary float Digital thermostat Media filter rack with 4” filter Clear drain Remove existing equipment Connect to existing ducts and electrical Seal unit to code Tax labor and permit included 10 year parts warranty 3 year labor warranty
St. Petersburg, FL 33702
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Added chemical to help prevent growth. Unit cooling properly at this time.
St. Petersburg, FL 33703
Upon my inspection, I found a bad capacitor. Replaced capacitor and checked amp draws on system. Compressor and fan motor have good amp draws. Rinsed condenser coils. Temperature split is 19°. 
System is cooling at this time.
Upon my inspection, I found a bad capacitor. Replaced capacitor and checked amp draws on system. Compressor and fan motor have good amp draws. Rinsed condenser coils. Temperature split is 19°. 
System is cooling at this time.
Michael A.
Michael A. Checked in
Upon my inspection, I found a bad capacitor. Replaced capacitor and checked amp draws on system. Compressor and fan motor have good amp draws. Rinsed condenser coils. Temperature split is 19°. System is cooling at this time.
St. Petersburg, FL 33714
Performed tune up on system. 
System has a 18° temperature split
Amp draws on compressor and fan motor are good
Cleaned and treated drain line/condensate pump. 
Rinsed condenser coils clean. 
Client shared concerns of a bad smell- I found growth above the air handler evaporator coil within the supply plenum. Recommended cleaning evaporator coil in place with cleaning the inside of the supply plenum with installation of a UV light system to prevent future growth. 
The pvc drain line does not currently have a p trap which is causing water to back up in the primary drain pan. Recommending to install a p trap and glue pvc joints. 
Discussed the possibility of installing a new heat pump system in place of the furnace in the future. 
System is cooling at this time.
Performed tune up on system. 
System has a 18° temperature split
Amp draws on compressor and fan motor are good
Cleaned and treated drain line/condensate pump. 
Rinsed condenser coils clean. 
Client shared concerns of a bad smell- I found growth above the air handler evaporator coil within the supply plenum. Recommended cleaning evaporator coil in place with cleaning the inside of the supply plenum with installation of a UV light system to prevent future growth. 
The pvc drain line does not currently have a p trap which is causing water to back up in the primary drain pan. Recommending to install a p trap and glue pvc joints. 
Discussed the possibility of installing a new heat pump system in place of the furnace in the future. 
System is cooling at this time.
Michael A.
Michael A. Checked in
Performed tune up on system. System has a 18° temperature split Amp draws on compressor and fan motor are good Cleaned and treated drain line/condensate pump. Rinsed condenser coils clean. Client shared concerns of a bad smell- I found growth above the air handler evaporator coil within the supply plenum. Recommended cleaning evaporator coil in place with cleaning the inside of the supply plenum with installation of a UV light system to prevent future growth. The pvc drain line does not currently have a p trap which is causing water to back up in the primary drain pan. Recommending to install a p trap and glue pvc joints. Discussed the possibility of installing a new heat pump system in place of the furnace in the future. System is cooling at this time.
St. Petersburg, FL 33702
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Added chemical to help prevent growth. Will submit estimate for condensate pump. Unit cooling at this time.
St. Petersburg, FL 33702
Justin G.
Justin G. Checked in
On arrival found downstairs unit not cooling due to low refrigerant in system. Performed leak search and found leak in evaporation coil. Will return tomorrow to replace coil and txv.
St. Petersburg, FL 33713
Performed tune up on system. Cleaned and treated drain line and primary drain pan. Rinsed condenser coils. Checked amp draws. Checked capacitor. 
System pressures indicated that system was low on refrigerant. Added 3lbs of 410a to reach target subcool of 10°. Will monitor system now that we have a good base line for possible leaks in the future. 
System is cooling at this time. 

Recommendations:
- sending quote for new system install due to system age. (Good reference for what to prepare for in the future).  quote is valid for 30 days
- recommending all new duct work with system replacement due to age and poor efficiency of existing duct work.
Performed tune up on system. Cleaned and treated drain line and primary drain pan. Rinsed condenser coils. Checked amp draws. Checked capacitor. 
System pressures indicated that system was low on refrigerant. Added 3lbs of 410a to reach target subcool of 10°. Will monitor system now that we have a good base line for possible leaks in the future. 
System is cooling at this time. 

Recommendations:
- sending quote for new system install due to system age. (Good reference for what to prepare for in the future).  quote is valid for 30 days
- recommending all new duct work with system replacement due to age and poor efficiency of existing duct work.
Michael A.
Michael A. Checked in
Performed tune up on system. Cleaned and treated drain line and primary drain pan. Rinsed condenser coils. Checked amp draws. Checked capacitor. System pressures indicated that system was low on refrigerant. Added 3lbs of 410a to reach target subcool of 10°. Will monitor system now that we have a good base line for possible leaks in the future. System is cooling at this time. Recommendations: - sending quote for new system install due to system age. (Good reference for what to prepare for in the future). quote is valid for 30 days - recommending all new duct work with system replacement due to age and poor efficiency of existing duct work.
St. Petersburg, FL 33713
Justin G.
Justin G. Checked in
Installed return grill.
St. Petersburg, FL 33705
Diagnose wiring issues. Replace MC cable from junction box to fresh air on roof
Diagnose wiring issues. Replace MC cable from junction box to fresh air on roof
Griffin K.
Griffin K. Checked in
Diagnose wiring issues. Replace MC cable from junction box to fresh air on roof
St. Petersburg, FL 33704
Drain pan backing up causing water to overflow into secondary drain pan. Growth accumulating within air primary drain pan not allowing water to drain. Recommend adding air purifier behind coil, pitching system/coil properly, sizing up drain line from 3/4” to 1” pvc, and adding primary safety switch. Went over options with home owner. Cleared drain line and pan. Discounted services from 360$ to 200$ as home owner is moving forward with scope of work. Unit is currently draining/cooling.
Drain pan backing up causing water to overflow into secondary drain pan. Growth accumulating within air primary drain pan not allowing water to drain. Recommend adding air purifier behind coil, pitching system/coil properly, sizing up drain line from 3/4” to 1” pvc, and adding primary safety switch. Went over options with home owner. Cleared drain line and pan. Discounted services from 360$ to 200$ as home owner is moving forward with scope of work. Unit is currently draining/cooling.
Nathan A.
Nathan A. Checked in
Drain pan backing up causing water to overflow into secondary drain pan. Growth accumulating within air primary drain pan not allowing water to drain. Recommend adding air purifier behind coil, pitching system/coil properly, sizing up drain line from 3/4” to 1” pvc, and adding primary safety switch. Went over options with home owner. Cleared drain line and pan. Discounted services from 360$ to 200$ as home owner is moving forward with scope of work. Unit is currently draining/cooling.
St. Petersburg, FL 33703
Justin G.
Justin G. Checked in
Found bedroom unit not cooling due to bad thermostat. Will return tomorrow replace thermostat.
St. Petersburg, FL 33701
Verified receptacles in bedrooms, living room, and kitchen had power to them for restoration company to plug in dehumidifiers 
Turned on ac breaker so units can cool the house
Verified receptacles in bedrooms, living room, and kitchen had power to them for restoration company to plug in dehumidifiers 
Turned on ac breaker so units can cool the house
Griffin K.
Griffin K. Checked in
Verified receptacles in bedrooms, living room, and kitchen had power to them for restoration company to plug in dehumidifiers Turned on ac breaker so units can cool the house
St. Petersburg, FL 33703
Mitsubishi mini split
2 ton system
10 year parts warranty
3 year labor warranty
-Wall mount bracket
-Mount unit high between generator and pool heater
-Line cover sealed 
-Insulated refrigerant lines
-Drain line
-Comm wire
-Breaker 
-Electrical run
Mitsubishi mini split
2 ton system
10 year parts warranty
3 year labor warranty
-Wall mount bracket
-Mount unit high between generator and pool heater
-Line cover sealed 
-Insulated refrigerant lines
-Drain line
-Comm wire
-Breaker 
-Electrical run
Martin W.
Martin W. Checked in
Mitsubishi mini split 2 ton system 10 year parts warranty 3 year labor warranty -Wall mount bracket -Mount unit high between generator and pool heater -Line cover sealed -Insulated refrigerant lines -Drain line -Comm wire -Breaker -Electrical run
St. Petersburg, FL 33704
St. Petersburg, FL - On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Added chemical to help prevent growth. Added refrigerant back to factory specs. Unit cooling at  this time.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Added chemical to help prevent growth. Added refrigerant back to factory specs. Unit cooling at this time.
St. Petersburg, FL 33713
Home owners state unit is not running and thermostat not lighting up. Found drain line backing up causing overflow safety to trip. Drain line had previous issues and currently has a non conventional pvc drain line. Flex line to pvc connection. Cleared drain line and drain pan. Verified system is cooling and draining. Went over maintenance on drain line as it may back up more frequently due to materials used. 

Waived 95$ and discounted drain cleaning
Home owners state unit is not running and thermostat not lighting up. Found drain line backing up causing overflow safety to trip. Drain line had previous issues and currently has a non conventional pvc drain line. Flex line to pvc connection. Cleared drain line and drain pan. Verified system is cooling and draining. Went over maintenance on drain line as it may back up more frequently due to materials used. 

Waived 95$ and discounted drain cleaning
Nathan A.
Nathan A. Checked in
Home owners state unit is not running and thermostat not lighting up. Found drain line backing up causing overflow safety to trip. Drain line had previous issues and currently has a non conventional pvc drain line. Flex line to pvc connection. Cleared drain line and drain pan. Verified system is cooling and draining. Went over maintenance on drain line as it may back up more frequently due to materials used. Waived 95$ and discounted drain cleaning
St. Petersburg, FL 33711
How do I know if my AC needs repair or full replacement?

Our technicians inspect the full system — age, refrigerant type, corrosion, and repair history — and give you an honest recommendation. If a repair makes sense, we'll fix it. If the unit is beyond its useful life, we'll walk you through replacement options with no pressure.

Are your technicians background-checked and licensed?

Yes. Every Air Bros technician is background-checked, factory-trained, and works under our state HVAC license (#CAC1820499) and electrical license (#EC13015085).

What parts of St. Petersburg do you serve?

We serve all of St. Petersburg, including Downtown, Historic Kenwood, Old Northeast, Snell Isle, Crescent Lake, Shore Acres, and Coquina Key, plus Seminole, Largo, Pinellas Park, and the surrounding beach communities.

Do you offer same-day AC repair in St. Petersburg?

Yes. We offer 24/7 emergency AC repair with same-day service throughout St. Petersburg and the surrounding Pinellas County area.

Is Air Bros a local St. Petersburg company, or a franchise?

Air Bros is 100% locally owned and operated, headquartered in the Shore Acres neighborhood of St. Petersburg. We're not a franchise — every technician is a direct employee, not a subcontractor.

Contact the Bros You Know Today!

Gravity Forms Pagination Must be Steps