Instant Quote Shop Filters Call Air Bros

St. Petersburg, FL

air-bros-team-with-truck

The Best AC Repair in St. Petersburg, FL — From Technicians Your Neighbors Already Trust

When your AC quits in the middle of a St. Pete summer, you don't want a stranger in an unmarked van. You want a technician your neighbors already know and trust. Air Bros Air Conditioning & Electrical has been fixing air conditioners in St. Petersburg since 2020, but our roots run deeper — founder Ricky Orta grew up learning the trade from his father and has been a licensed HVAC contractor since 2006. That local, hands-on experience is why homeowners from Historic Kenwood to Snell Isle call us the best AC repair company in St. Petersburg.

We're headquartered right here in the Shore Acres neighborhood, so when you call, you're not routed to a call center — you're talking to the same local team that services your street.

Call us at 727-217-6148 or contact us online today for all of your HVAC, indoor air quality and electrical needs.

Meet the technicians who service St. Petersburg

What to expect when we show up

Calling a repair company you've never used before shouldn't feel like a gamble. Here's exactly how an Air Bros service call goes, every time.

You'll get a heads-up before we arrive, then a uniformed technician in a marked Air Bros vehicle shows up in the window we promised. We diagnose the whole system — not just the obvious symptom — then explain what we found and what your options are before any work starts. You approve the price up front, we make the repair, and we don't leave until we've confirmed the system is cooling the way it should.

Every technician is a background-checked, drug-tested Air Bros employee — never a subcontractor — and each one is trained to service every major AC and heat pump brand. It's the kind of consistency you can only get from a local team that answers to its own name.

And if something isn't right? Our 100% satisfaction guarantee means we make it right.

Signs you need AC repair

St. Petersburg's heat and humidity push air conditioners harder than almost anywhere else in the country. Call for AC repair if you notice:

  • Warm air blowing from vents, or the system running constantly without cooling
  • Water pooling around your air handler (a common issue in St. Pete's older homes with attic-run drain lines)
  • Musty odors or visible mold near vents — a sign of a clogged condensate line or dirty coil
  • Rising humidity indoors despite the AC running
  • Short cycling, tripped breakers, or a system that won't turn on at all

Our technicians diagnose the full system on every call — refrigerant charge, temperature split, electrical connections, and drain line — so you get a real fix, not a temporary patch.

Comprehensive HVAC Services in St. Petersburg

We offer a full range of heating and cooling services to keep your St. Petersburg, FL, home comfortable year-round:

  • Air Conditioning: From AC repair and AC installation to routine maintenance, we ensure your cooling system keeps you comfortable during those hot Florida summers. We offer same-day service for AC emergencies, so you never have to suffer in the heat.
  • Heating: Stay warm and cozy in the winter with our comprehensive heating services. We repair and install all types of heating systems, including furnaces and heat pumps, and offer preventative maintenance to keep your system running efficiently.
  • Indoor Air Quality: Improve your indoor air quality with our dehumidifier and UV light installation services. We'll help you control excess humidity and eliminate airborne contaminants, creating a healthier home environment.
  • Ductwork: Ensure optimal airflow and energy efficiency with our ductwork repair and installation services. We can address leaks and damage, and design a system that's perfect for your home.
  • Pool Heater Services: Extend your swim season with our pool heater installation and repair services.
  • Electrical Services: From outlet and switch replacements to ceiling fan installations to whole-house surge protector installations, we have the experts to handle your electrical service needs.

Our experienced technicians are skilled in all aspects of HVAC service and are dedicated to providing top-quality workmanship and customer care.

Why Choose Air Bros?

  • Local Expertise: We understand the unique climate challenges of St. Petersburg.
  • Fast and Reliable Service: We offer same-day service for AC emergencies and prioritize prompt service for all your HVAC needs.
  • Experienced Technicians: Our team is highly trained and experienced in all aspects of HVAC service.
  • Upfront Pricing: We provide transparent pricing with no hidden costs.
  • Customer Satisfaction Guaranteed: Your comfort and satisfaction are our top priorities.

Contact Air Bros Today!

Whether you need emergency AC repair, a new heating system installation, or any other HVAC service, Air Bros is here to help. Contact us today for a free consultation or to schedule a service appointment. We're proud to be your trusted HVAC partner in St. Petersburg!

Call us at 727-217-6148 or contact us online today!

Recent Jobs and Reviews in St. Petersburg, FL

St. Petersburg, FL at a glance

Air Bros Air Conditioning & Electrical has completed 25 jobs in St. Petersburg, FL in October 2025.

The most recent job was on October 8, 2025.

Air Bros Air Conditioning & Electrical has completed 1,919 jobs in St. Petersburg, FL in the last 12 months. The first job there was in December 2024.

Job Locations and Reviews

Home owner states unit is running but blowing warm air. Found roof top condenser capacitor failed and contactor pitted and rusted. Replaced both components and verified operations. 

Unit may run longer or struggle to keep up due to construction in flooded condo. Recommend changing filters frequently. 


Discounted repairs from 745$ to 595$
Home owner states unit is running but blowing warm air. Found roof top condenser capacitor failed and contactor pitted and rusted. Replaced both components and verified operations. 

Unit may run longer or struggle to keep up due to construction in flooded condo. Recommend changing filters frequently. 


Discounted repairs from 745$ to 595$
Nathan A.
Nathan A. Checked in
Home owner states unit is running but blowing warm air. Found roof top condenser capacitor failed and contactor pitted and rusted. Replaced both components and verified operations. Unit may run longer or struggle to keep up due to construction in flooded condo. Recommend changing filters frequently. Discounted repairs from 745$ to 595$
St. Petersburg, FL 33703
Install new dedicated circuit from panel to dryer location and install a wall receptacle for electrical connection 
Run wires under home in the crawl space 
Run the dryer went out the side of home through the closet space
Install new dedicated circuit from panel to dryer location and install a wall receptacle for electrical connection 
Run wires under home in the crawl space 
Run the dryer went out the side of home through the closet space
Griffin K.
Griffin K. Checked in
Install new dedicated circuit from panel to dryer location and install a wall receptacle for electrical connection Run wires under home in the crawl space Run the dryer went out the side of home through the closet space
St. Petersburg, FL 33714
Home owner states unit is not keeping up and only shutting off at night. Found system running low on refrigerant indicating leak. Went over options to leak search unit. Home owner would like to gas system and potentially replace/repair. Explained we can not guarantee how long refrigerant will last. Added back to factory specifications and verified system is operating. System is 10 years of age and second home owner (out of warranty). Explained potential repairs/cost.
Home owner states unit is not keeping up and only shutting off at night. Found system running low on refrigerant indicating leak. Went over options to leak search unit. Home owner would like to gas system and potentially replace/repair. Explained we can not guarantee how long refrigerant will last. Added back to factory specifications and verified system is operating. System is 10 years of age and second home owner (out of warranty). Explained potential repairs/cost.
Nathan A.
Nathan A. Checked in
Home owner states unit is not keeping up and only shutting off at night. Found system running low on refrigerant indicating leak. Went over options to leak search unit. Home owner would like to gas system and potentially replace/repair. Explained we can not guarantee how long refrigerant will last. Added back to factory specifications and verified system is operating. System is 10 years of age and second home owner (out of warranty). Explained potential repairs/cost.
St. Petersburg, FL 33702
On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Added chemical to help prevent growth. Performed maintenance. Found evaporation coil dirty. Client declined cleaning at this time. Unit has 20* split. Unit cooling properly at this time.
On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Added chemical to help prevent growth. Performed maintenance. Found evaporation coil dirty. Client declined cleaning at this time. Unit has 20* split. Unit cooling properly at this time.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Added chemical to help prevent growth. Performed maintenance. Found evaporation coil dirty. Client declined cleaning at this time. Unit has 20* split. Unit cooling properly at this time.
St. Petersburg, FL 33701
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Added client to 2 times per year maintenance plan for added benefit. Unit cooling properly at this time. If problem persists we recommend a condensate pump or chemical pump to help keep drain clear.
St. Petersburg, FL 33712
St. Petersburg, FL - Replace changeover coil and defrost board. Unit cooling properly at this time. Unit has 20* split.
Justin G.
Justin G. Checked in
Replace changeover coil and defrost board. Unit cooling properly at this time. Unit has 20* split.
St. Petersburg, FL 33703
On arrival found unit not cooling due to bad relay for blower. Bypassed relay to allow blower to run. Unit is frozen in attic and cannot  check pressures at this time. Made client aware of condition and age of system. Unit is 25 year in of r22 in very poor shape. Recommend to replace system for proper and efficient cooling. Will submit estimate for replacement option.
On arrival found unit not cooling due to bad relay for blower. Bypassed relay to allow blower to run. Unit is frozen in attic and cannot  check pressures at this time. Made client aware of condition and age of system. Unit is 25 year in of r22 in very poor shape. Recommend to replace system for proper and efficient cooling. Will submit estimate for replacement option.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to bad relay for blower. Bypassed relay to allow blower to run. Unit is frozen in attic and cannot check pressures at this time. Made client aware of condition and age of system. Unit is 25 year in of r22 in very poor shape. Recommend to replace system for proper and efficient cooling. Will submit estimate for replacement option.
St. Petersburg, FL 33704
St. Petersburg, FL - On arrival found unit not cooling due to low voltage short and burnt transformer. Replaced transformer. Found revering valve solenoid shorted. Will submit estimate for board and solenoid. Unit not cooling.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to low voltage short and burnt transformer. Replaced transformer. Found revering valve solenoid shorted. Will submit estimate for board and solenoid. Unit not cooling.
St. Petersburg, FL 33703
On arrival found unit not cooling due to low refrigerant. Found condenser coil leaking. Will submit estimate for coil replacement.
On arrival found unit not cooling due to low refrigerant. Found condenser coil leaking. Will submit estimate for coil replacement.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to low refrigerant. Found condenser coil leaking. Will submit estimate for coil replacement.
St. Petersburg, FL 33703
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Fan motor amp draw is right at it max rating of .6. Advised client this could be a concern with the noise she is hearing and wearing out the capacitor.  Checked capacitor is out of factory range. Replaced capacitor. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Fan motor amp draw is right at it max rating of .6. Advised client this could be a concern with the noise she is hearing and wearing out the capacitor.  Checked capacitor is out of factory range. Replaced capacitor. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.
Michael A.
Michael A. Checked in
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Fan motor amp draw is right at it max rating of .6. Advised client this could be a concern with the noise she is hearing and wearing out the capacitor. Checked capacitor is out of factory range. Replaced capacitor. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.
St. Petersburg, FL 33703
Replace the bad GFCI breaker in the exterior sub panel for gas tankless water heater and kitchen receptacles 
Replace the bad GFCI receptacle at the front of the home that will not reset
Replace the bad GFCI breaker in the exterior sub panel for gas tankless water heater and kitchen receptacles 
Replace the bad GFCI receptacle at the front of the home that will not reset
Griffin K.
Griffin K. Checked in
Replace the bad GFCI breaker in the exterior sub panel for gas tankless water heater and kitchen receptacles Replace the bad GFCI receptacle at the front of the home that will not reset
St. Petersburg, FL 33705
Estimate to replace system 

Front Draw System 2012

Diagnostic
-Drain line heavily backed up and causing overflow 
-Air handler cabinet rusting due to water 
-Safety switch not operating due to buildup (stuck in place)
-Debri buildup on air handler blower wheel  
-Capacitor reading weak/terminals rusting
Estimate to replace system 

Front Draw System 2012

Diagnostic
-Drain line heavily backed up and causing overflow 
-Air handler cabinet rusting due to water 
-Safety switch not operating due to buildup (stuck in place)
-Debri buildup on air handler blower wheel  
-Capacitor reading weak/terminals rusting
Nathan A.
Nathan A. Checked in
Estimate to replace system Front Draw System 2012 Diagnostic -Drain line heavily backed up and causing overflow -Air handler cabinet rusting due to water -Safety switch not operating due to buildup (stuck in place) -Debri buildup on air handler blower wheel -Capacitor reading weak/terminals rusting
St. Petersburg, FL 33701
2 Head 1 Condenser 

Carrier Mini Split 

Tenant states unit has been intermittently cooling. Found error code on head unit indicating airflow/refrigerant issues. Found outdoor motor failing (not fully ramping up) causing system to shut off on high head pressure. Explained that they should not run system because it can cause further damage.
2 Head 1 Condenser 

Carrier Mini Split 

Tenant states unit has been intermittently cooling. Found error code on head unit indicating airflow/refrigerant issues. Found outdoor motor failing (not fully ramping up) causing system to shut off on high head pressure. Explained that they should not run system because it can cause further damage.
Nathan A.
Nathan A. Checked in
2 Head 1 Condenser Carrier Mini Split Tenant states unit has been intermittently cooling. Found error code on head unit indicating airflow/refrigerant issues. Found outdoor motor failing (not fully ramping up) causing system to shut off on high head pressure. Explained that they should not run system because it can cause further damage.
St. Petersburg, FL 33701
4 ton Ruud Heat Pump
15 seer
10 year parts warranty
5 year labor warranty
4 ton Ruud Heat Pump
15 seer
10 year parts warranty
5 year labor warranty
Nathan A.
Nathan A. Checked in
4 ton Ruud Heat Pump 15 seer 10 year parts warranty 5 year labor warranty
St. Petersburg, FL 33703
Justin G.
Justin G. Checked in
Inspected attic for rodent activity. Ducts good. Unit cooling properly. Found no signs in attic of rodents. Recommend to still get pest control for preventative measures.
St. Petersburg, FL 33702
Clean blower and coil in place. Tax and labor included. Performed maintenance.
Clean blower and coil in place. Tax and labor included. Performed maintenance.
Justin G.
Justin G. Checked in
Clean blower and coil in place. Tax and labor included. Performed maintenance.
St. Petersburg, FL 33710
Performed Tune up on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Blower motor/wheel/housing are impacted with biological growth. Verified safety float switch functionality. Checked amp draw on compressor. Compressor and over amping on start up. Compressor pulls 82 amps and LRA is 77 amps.Checked amp draw on fan motor. Indoor blower motor capacitor is bad. Checked condenser capacitor is also out of factory range. Performed blower removal and cleaning, replaced both capacitors, made a new connection with 3ft of thermostat wire at condenser unit due to corrosion, Installed hard start kit and brought the start up amp draw down to 54. Made sure client knows that the hard start kit is a bandaid option and not a permanent solution for her compressor. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. 

Notes: 
Advised client that their Contactar is making a small chatter noise and
Performed Tune up on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Blower motor/wheel/housing are impacted with biological growth. Verified safety float switch functionality. Checked amp draw on compressor. Compressor and over amping on start up. Compressor pulls 82 amps and LRA is 77 amps.Checked amp draw on fan motor. Indoor blower motor capacitor is bad. Checked condenser capacitor is also out of factory range. Performed blower removal and cleaning, replaced both capacitors, made a new connection with 3ft of thermostat wire at condenser unit due to corrosion, Installed hard start kit and brought the start up amp draw down to 54. Made sure client knows that the hard start kit is a bandaid option and not a permanent solution for her compressor. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. 

Notes: 
Advised client that their Contactar is making a small chatter noise and
Michael A.
Michael A. Checked in
Performed Tune up on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Blower motor/wheel/housing are impacted with biological growth. Verified safety float switch functionality. Checked amp draw on compressor. Compressor and over amping on start up. Compressor pulls 82 amps and LRA is 77 amps.Checked amp draw on fan motor. Indoor blower motor capacitor is bad. Checked condenser capacitor is also out of factory range. Performed blower removal and cleaning, replaced both capacitors, made a new connection with 3ft of thermostat wire at condenser unit due to corrosion, Installed hard start kit and brought the start up amp draw down to 54. Made sure client knows that the hard start kit is a bandaid option and not a permanent solution for her compressor. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. Notes: Advised client that their Contactar is making a small chatter noise and
St. Petersburg, FL 33703
Replaced the TXV pulled and cleaned blower motor sealed all ductwork tested unit operations. Everything working amazing
Replaced the TXV pulled and cleaned blower motor sealed all ductwork tested unit operations. Everything working amazing
Kyle K.
Kyle K. Checked in
Replaced the TXV pulled and cleaned blower motor sealed all ductwork tested unit operations. Everything working amazing
St. Petersburg, FL 33701
Ricky O.
Ricky O. Checked in
Cleaned drain line and pan. Cut and blew out line. Verified proper operation
St. Petersburg, FL 33702
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to weak capacitor. Replaced part. Start and test. Temp split good. Amp draws good. Unit cooling properly at this time.
St. Petersburg, FL 33702
Griffin K.
Griffin K. Checked in
Remove the wires going down to the outlet under tv Add them into a junction box in the attic and then run a new line down to that outlet when the window is put in *** not responsible for drywall damage
St. Petersburg, FL 33710
Furnish and install the following 
3 ton Ruud 19 seer2 heat pump inverter split system with 5kw heater with breaker
Anchor condenser
Surge protection 
Ruud WiFi thermostat
Insulated return stand
4” media filter
Uv air purifier 
Condensate pump
New beaker for air handler
Cap off existing gas line and shut valve
Clear drain
Primary float switch
Remove existing equipment 
Connect to existing ducts and electrical 
Seal unit to code
Tax labor and permit included
10 year parts warranty 
3 year labor warranty 
** Unit eligible for $2000.00 tax credit**
Full variable speed
Most efficient 
Quietest unit
Price includes $200 discount for capacitor 
Price  only valid if paying with check
Furnish and install the following 
3 ton Ruud 19 seer2 heat pump inverter split system with 5kw heater with breaker
Anchor condenser
Surge protection 
Ruud WiFi thermostat
Insulated return stand
4” media filter
Uv air purifier 
Condensate pump
New beaker for air handler
Cap off existing gas line and shut valve
Clear drain
Primary float switch
Remove existing equipment 
Connect to existing ducts and electrical 
Seal unit to code
Tax labor and permit included
10 year parts warranty 
3 year labor warranty 
** Unit eligible for $2000.00 tax credit**
Full variable speed
Most efficient 
Quietest unit
Price includes $200 discount for capacitor 
Price  only valid if paying with check
Martin W.
Martin W. Checked in
Furnish and install the following 3 ton Ruud 19 seer2 heat pump inverter split system with 5kw heater with breaker Anchor condenser Surge protection Ruud WiFi thermostat Insulated return stand 4” media filter Uv air purifier Condensate pump New beaker for air handler Cap off existing gas line and shut valve Clear drain Primary float switch Remove existing equipment Connect to existing ducts and electrical Seal unit to code Tax labor and permit included 10 year parts warranty 3 year labor warranty ** Unit eligible for $2000.00 tax credit** Full variable speed Most efficient Quietest unit Price includes $200 discount for capacitor Price only valid if paying with check
St. Petersburg, FL 33704
On arrival found unit leaking water in return due to dirty evap coil. Water also leaking past pan due to design of coil. Explained to client a pull and clean will get coil clean, however unit might still leak water due to design. Coil replacement has new redesigned coil to prevent water getting past pan. Will submit estimates for coil cleaning, coil replacement, and full system replacement. Unit cooling at this time.
On arrival found unit leaking water in return due to dirty evap coil. Water also leaking past pan due to design of coil. Explained to client a pull and clean will get coil clean, however unit might still leak water due to design. Coil replacement has new redesigned coil to prevent water getting past pan. Will submit estimates for coil cleaning, coil replacement, and full system replacement. Unit cooling at this time.
Justin G.
Justin G. Checked in
On arrival found unit leaking water in return due to dirty evap coil. Water also leaking past pan due to design of coil. Explained to client a pull and clean will get coil clean, however unit might still leak water due to design. Coil replacement has new redesigned coil to prevent water getting past pan. Will submit estimates for coil cleaning, coil replacement, and full system replacement. Unit cooling at this time.
St. Petersburg, FL 33703
Performed Tune up on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Compressor start up amp draw is over it max LRA at 126 with a max of 108. Installed hard start kit to remedy the failing start windings on the compressor and achieved a start up amp draw of 82. Checked amp draw on fan motor. Checked capacitor is within factory range. made sure all connections are tight. System is cooling with a 20° temperature split at this time.
Performed Tune up on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Compressor start up amp draw is over it max LRA at 126 with a max of 108. Installed hard start kit to remedy the failing start windings on the compressor and achieved a start up amp draw of 82. Checked amp draw on fan motor. Checked capacitor is within factory range. made sure all connections are tight. System is cooling with a 20° temperature split at this time.
Michael A.
Michael A. Checked in
Performed Tune up on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Compressor start up amp draw is over it max LRA at 126 with a max of 108. Installed hard start kit to remedy the failing start windings on the compressor and achieved a start up amp draw of 82. Checked amp draw on fan motor. Checked capacitor is within factory range. made sure all connections are tight. System is cooling with a 20° temperature split at this time.
St. Petersburg, FL 33705
Tenant states system is freezing over and not turning off. System is turning off, possibly hearing the window unit next to the outdoor unit. 

System is freezing over currently. Air handler coils severely impacted. Would need to replace air handler coils to further diagnose. System is mis matched. Explained we can attempt repairs but can not guarantee no further issues. Would recommend replacing with warranty and permit. 

Bacterial growth acclimating inside of air handler. Outdoor condenser data tag scraped off. 

Will call manufacture to verify parts and availability 

Spoke to property manager
Tenant states system is freezing over and not turning off. System is turning off, possibly hearing the window unit next to the outdoor unit. 

System is freezing over currently. Air handler coils severely impacted. Would need to replace air handler coils to further diagnose. System is mis matched. Explained we can attempt repairs but can not guarantee no further issues. Would recommend replacing with warranty and permit. 

Bacterial growth acclimating inside of air handler. Outdoor condenser data tag scraped off. 

Will call manufacture to verify parts and availability 

Spoke to property manager
Nathan A.
Nathan A. Checked in
Tenant states system is freezing over and not turning off. System is turning off, possibly hearing the window unit next to the outdoor unit. System is freezing over currently. Air handler coils severely impacted. Would need to replace air handler coils to further diagnose. System is mis matched. Explained we can attempt repairs but can not guarantee no further issues. Would recommend replacing with warranty and permit. Bacterial growth acclimating inside of air handler. Outdoor condenser data tag scraped off. Will call manufacture to verify parts and availability Spoke to property manager
St. Petersburg, FL 33712
How do I know if my AC needs repair or full replacement?

Our technicians inspect the full system — age, refrigerant type, corrosion, and repair history — and give you an honest recommendation. If a repair makes sense, we'll fix it. If the unit is beyond its useful life, we'll walk you through replacement options with no pressure.

Are your technicians background-checked and licensed?

Yes. Every Air Bros technician is background-checked, factory-trained, and works under our state HVAC license (#CAC1820499) and electrical license (#EC13015085).

What parts of St. Petersburg do you serve?

We serve all of St. Petersburg, including Downtown, Historic Kenwood, Old Northeast, Snell Isle, Crescent Lake, Shore Acres, and Coquina Key, plus Seminole, Largo, Pinellas Park, and the surrounding beach communities.

Do you offer same-day AC repair in St. Petersburg?

Yes. We offer 24/7 emergency AC repair with same-day service throughout St. Petersburg and the surrounding Pinellas County area.

Is Air Bros a local St. Petersburg company, or a franchise?

Air Bros is 100% locally owned and operated, headquartered in the Shore Acres neighborhood of St. Petersburg. We're not a franchise — every technician is a direct employee, not a subcontractor.

Contact the Bros You Know Today!

Gravity Forms Pagination Must be Steps