Instant Quote Shop Filters Call Air Bros

St. Petersburg, FL

air-bros-team-with-truck

The Best AC Repair in St. Petersburg, FL — From Technicians Your Neighbors Already Trust

When your AC quits in the middle of a St. Pete summer, you don't want a stranger in an unmarked van. You want a technician your neighbors already know and trust. Air Bros Air Conditioning & Electrical has been fixing air conditioners in St. Petersburg since 2020, but our roots run deeper — founder Ricky Orta grew up learning the trade from his father and has been a licensed HVAC contractor since 2006. That local, hands-on experience is why homeowners from Historic Kenwood to Snell Isle call us the best AC repair company in St. Petersburg.

We're headquartered right here in the Shore Acres neighborhood, so when you call, you're not routed to a call center — you're talking to the same local team that services your street.

Call us at 727-217-6148 or contact us online today for all of your HVAC, indoor air quality and electrical needs.

Meet the technicians who service St. Petersburg

What to expect when we show up

Calling a repair company you've never used before shouldn't feel like a gamble. Here's exactly how an Air Bros service call goes, every time.

You'll get a heads-up before we arrive, then a uniformed technician in a marked Air Bros vehicle shows up in the window we promised. We diagnose the whole system — not just the obvious symptom — then explain what we found and what your options are before any work starts. You approve the price up front, we make the repair, and we don't leave until we've confirmed the system is cooling the way it should.

Every technician is a background-checked, drug-tested Air Bros employee — never a subcontractor — and each one is trained to service every major AC and heat pump brand. It's the kind of consistency you can only get from a local team that answers to its own name.

And if something isn't right? Our 100% satisfaction guarantee means we make it right.

Signs you need AC repair

St. Petersburg's heat and humidity push air conditioners harder than almost anywhere else in the country. Call for AC repair if you notice:

  • Warm air blowing from vents, or the system running constantly without cooling
  • Water pooling around your air handler (a common issue in St. Pete's older homes with attic-run drain lines)
  • Musty odors or visible mold near vents — a sign of a clogged condensate line or dirty coil
  • Rising humidity indoors despite the AC running
  • Short cycling, tripped breakers, or a system that won't turn on at all

Our technicians diagnose the full system on every call — refrigerant charge, temperature split, electrical connections, and drain line — so you get a real fix, not a temporary patch.

Comprehensive HVAC Services in St. Petersburg

We offer a full range of heating and cooling services to keep your St. Petersburg, FL, home comfortable year-round:

  • Air Conditioning: From AC repair and AC installation to routine maintenance, we ensure your cooling system keeps you comfortable during those hot Florida summers. We offer same-day service for AC emergencies, so you never have to suffer in the heat.
  • Heating: Stay warm and cozy in the winter with our comprehensive heating services. We repair and install all types of heating systems, including furnaces and heat pumps, and offer preventative maintenance to keep your system running efficiently.
  • Indoor Air Quality: Improve your indoor air quality with our dehumidifier and UV light installation services. We'll help you control excess humidity and eliminate airborne contaminants, creating a healthier home environment.
  • Ductwork: Ensure optimal airflow and energy efficiency with our ductwork repair and installation services. We can address leaks and damage, and design a system that's perfect for your home.
  • Pool Heater Services: Extend your swim season with our pool heater installation and repair services.
  • Electrical Services: From outlet and switch replacements to ceiling fan installations to whole-house surge protector installations, we have the experts to handle your electrical service needs.

Our experienced technicians are skilled in all aspects of HVAC service and are dedicated to providing top-quality workmanship and customer care.

Why Choose Air Bros?

  • Local Expertise: We understand the unique climate challenges of St. Petersburg.
  • Fast and Reliable Service: We offer same-day service for AC emergencies and prioritize prompt service for all your HVAC needs.
  • Experienced Technicians: Our team is highly trained and experienced in all aspects of HVAC service.
  • Upfront Pricing: We provide transparent pricing with no hidden costs.
  • Customer Satisfaction Guaranteed: Your comfort and satisfaction are our top priorities.

Contact Air Bros Today!

Whether you need emergency AC repair, a new heating system installation, or any other HVAC service, Air Bros is here to help. Contact us today for a free consultation or to schedule a service appointment. We're proud to be your trusted HVAC partner in St. Petersburg!

Call us at 727-217-6148 or contact us online today!

Recent Jobs and Reviews in St. Petersburg, FL

St. Petersburg, FL at a glance

Air Bros Air Conditioning & Electrical has completed 25 jobs in St. Petersburg, FL in January 2026.

The most recent job was on January 13, 2026.

Air Bros Air Conditioning & Electrical has completed 1,919 jobs in St. Petersburg, FL in the last 12 months. The first job there was in December 2024.

Job Locations and Reviews

Griffin K.
Griffin K. Checked in
Replace bad light with one provided by customer
St. Petersburg, FL 33703
Performed Tune ups on mini split systems. 
- Cleaned condenser coils. 
- Cleaner Evaporator coils. 
- Cleaned and treated drain lines & primary drain pans. 
- Cleaned air filters. 
- Checked Temperature Splits. 18-19° splits (good). 
- Inspected Blower wheels on both head units and found a substantial amount of Microbial Growth. 
- Quotes sent for Cleanings and UV Prevention. 
- Quote sent for membership Maitenence plan to receive 10% discount on cleanings and UV installs. 
- Client is sending quotes to Owner of the home.
Performed Tune ups on mini split systems. 
- Cleaned condenser coils. 
- Cleaner Evaporator coils. 
- Cleaned and treated drain lines & primary drain pans. 
- Cleaned air filters. 
- Checked Temperature Splits. 18-19° splits (good). 
- Inspected Blower wheels on both head units and found a substantial amount of Microbial Growth. 
- Quotes sent for Cleanings and UV Prevention. 
- Quote sent for membership Maitenence plan to receive 10% discount on cleanings and UV installs. 
- Client is sending quotes to Owner of the home.
Michael A.
Michael A. Checked in
Performed Tune ups on mini split systems. - Cleaned condenser coils. - Cleaner Evaporator coils. - Cleaned and treated drain lines & primary drain pans. - Cleaned air filters. - Checked Temperature Splits. 18-19° splits (good). - Inspected Blower wheels on both head units and found a substantial amount of Microbial Growth. - Quotes sent for Cleanings and UV Prevention. - Quote sent for membership Maitenence plan to receive 10% discount on cleanings and UV installs. - Client is sending quotes to Owner of the home.
St. Petersburg, FL 33707
Ruud 14.3 seer2 heat pump split system with 5kw heater
2.5 ton
Hurricane pad
Anchor condenser
Digital thermostat
Horizontal attic
Aux pan
Primary and secondary float switch
Remove existing equipment 
Connect to existing ducts and electrical 
Seal unit to code
Tax labor and permit included 
10 year parts warranty 
3 year labor warranty
Ruud 14.3 seer2 heat pump split system with 5kw heater
2.5 ton
Hurricane pad
Anchor condenser
Digital thermostat
Horizontal attic
Aux pan
Primary and secondary float switch
Remove existing equipment 
Connect to existing ducts and electrical 
Seal unit to code
Tax labor and permit included 
10 year parts warranty 
3 year labor warranty
Martin W.
Martin W. Checked in
Ruud 14.3 seer2 heat pump split system with 5kw heater 2.5 ton Hurricane pad Anchor condenser Digital thermostat Horizontal attic Aux pan Primary and secondary float switch Remove existing equipment Connect to existing ducts and electrical Seal unit to code Tax labor and permit included 10 year parts warranty 3 year labor warranty
St. Petersburg, FL 33704
Install 50 A GFCI breaker 
Make up customer ran wire into panel and into spa equipment 
Add tandem breakers to make space for circuit 
Customer installed and ran conduit from panel to spa 
It is the correct size wiring 
Install new 2 pole 50 amp GFCI breaker per spa manufacture and wire up spa control box
Install 50 A GFCI breaker 
Make up customer ran wire into panel and into spa equipment 
Add tandem breakers to make space for circuit 
Customer installed and ran conduit from panel to spa 
It is the correct size wiring 
Install new 2 pole 50 amp GFCI breaker per spa manufacture and wire up spa control box
Griffin K.
Griffin K. Checked in
Install 50 A GFCI breaker Make up customer ran wire into panel and into spa equipment Add tandem breakers to make space for circuit Customer installed and ran conduit from panel to spa It is the correct size wiring Install new 2 pole 50 amp GFCI breaker per spa manufacture and wire up spa control box
St. Petersburg, FL 33710
Client states that when turning on heat, smoke came out of vents. Inspected unit and found heat strip turning on for first time caused dust to burn off and produce smoke in home. Amp draws good. Temp split good. All connections are tight. Found aux pan below unit to not fully cover air handler and does not have float switch. Blower is dirty with growth and debris. Recommend to add float switch and move pan, pull and clean blower wheel, and add uv treatment to system to prevent growth in air handler. Changed all filters. Unit operating properly at this time. Made client aware without safety switch and pan properly positioned below unit, possible ceiling damage if unit leaks in attic.
Client states that when turning on heat, smoke came out of vents. Inspected unit and found heat strip turning on for first time caused dust to burn off and produce smoke in home. Amp draws good. Temp split good. All connections are tight. Found aux pan below unit to not fully cover air handler and does not have float switch. Blower is dirty with growth and debris. Recommend to add float switch and move pan, pull and clean blower wheel, and add uv treatment to system to prevent growth in air handler. Changed all filters. Unit operating properly at this time. Made client aware without safety switch and pan properly positioned below unit, possible ceiling damage if unit leaks in attic.
Justin G.
Justin G. Checked in
Client states that when turning on heat, smoke came out of vents. Inspected unit and found heat strip turning on for first time caused dust to burn off and produce smoke in home. Amp draws good. Temp split good. All connections are tight. Found aux pan below unit to not fully cover air handler and does not have float switch. Blower is dirty with growth and debris. Recommend to add float switch and move pan, pull and clean blower wheel, and add uv treatment to system to prevent growth in air handler. Changed all filters. Unit operating properly at this time. Made client aware without safety switch and pan properly positioned below unit, possible ceiling damage if unit leaks in attic.
St. Petersburg, FL 33704
On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Added chemical to help prevent growth. Found unit to have weak capacitor and dirty evaporator coil. Recommended to clean coil and replace capacitor to prevent future breakdowns. Client declined at this time. Offered repairs at discount. Made client aware will be more expensive to return to perform work. Unit operating properly at this time.
On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Added chemical to help prevent growth. Found unit to have weak capacitor and dirty evaporator coil. Recommended to clean coil and replace capacitor to prevent future breakdowns. Client declined at this time. Offered repairs at discount. Made client aware will be more expensive to return to perform work. Unit operating properly at this time.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Added chemical to help prevent growth. Found unit to have weak capacitor and dirty evaporator coil. Recommended to clean coil and replace capacitor to prevent future breakdowns. Client declined at this time. Offered repairs at discount. Made client aware will be more expensive to return to perform work. Unit operating properly at this time.
St. Petersburg, FL 33702
Upon arrival home owner states unit isn’t cooling or heating. Found high voltage connections to heater kit contactor burnt. Connections shorted out and burnt up contactor. Cloth wiring coming for air handler disconnect to air handler. Replaced contactor, re did connections (low/high voltage), and replaced 3 amp fuse. Tested cooling and heating. After letting heat run for 5-10 minutes breaker tripped. Unit is only pulling 40 amps and breaker rated for 60. Would recommend replacing breaker and whip together 

Bacterial growth starting to accumulate inside air handler 

Recommend replacing cloth wiring high voltage whip (air handler)

Air handler coils impacted with debris/growth (recommend cleaning)

Home owner putting new filter in today
Upon arrival home owner states unit isn’t cooling or heating. Found high voltage connections to heater kit contactor burnt. Connections shorted out and burnt up contactor. Cloth wiring coming for air handler disconnect to air handler. Replaced contactor, re did connections (low/high voltage), and replaced 3 amp fuse. Tested cooling and heating. After letting heat run for 5-10 minutes breaker tripped. Unit is only pulling 40 amps and breaker rated for 60. Would recommend replacing breaker and whip together 

Bacterial growth starting to accumulate inside air handler 

Recommend replacing cloth wiring high voltage whip (air handler)

Air handler coils impacted with debris/growth (recommend cleaning)

Home owner putting new filter in today
Nathan A.
Nathan A. Checked in
Upon arrival home owner states unit isn’t cooling or heating. Found high voltage connections to heater kit contactor burnt. Connections shorted out and burnt up contactor. Cloth wiring coming for air handler disconnect to air handler. Replaced contactor, re did connections (low/high voltage), and replaced 3 amp fuse. Tested cooling and heating. After letting heat run for 5-10 minutes breaker tripped. Unit is only pulling 40 amps and breaker rated for 60. Would recommend replacing breaker and whip together Bacterial growth starting to accumulate inside air handler Recommend replacing cloth wiring high voltage whip (air handler) Air handler coils impacted with debris/growth (recommend cleaning) Home owner putting new filter in today
St. Petersburg, FL 33712
Home owner states unit was leaking at pvc joint. Found insulating to refrigerant lines lacking above problematic joint. Re insulated drain line. Verified system was draining. Drain line connection was pipe putty in and explained that we could crack drain pan when undoing connection. Will send estimate over to replace pan and re do all pvc connections.
Home owner states unit was leaking at pvc joint. Found insulating to refrigerant lines lacking above problematic joint. Re insulated drain line. Verified system was draining. Drain line connection was pipe putty in and explained that we could crack drain pan when undoing connection. Will send estimate over to replace pan and re do all pvc connections.
Nathan A.
Nathan A. Checked in
Home owner states unit was leaking at pvc joint. Found insulating to refrigerant lines lacking above problematic joint. Re insulated drain line. Verified system was draining. Drain line connection was pipe putty in and explained that we could crack drain pan when undoing connection. Will send estimate over to replace pan and re do all pvc connections.
St. Petersburg, FL 33705
Replaced copper lineset and communication wite.. ran vacuum under 500 microns and charged system with R410A.. system is now running properly
Replaced copper lineset and communication wite.. ran vacuum under 500 microns and charged system with R410A.. system is now running properly
Martin W.
Martin W. Checked in
Replaced copper lineset and communication wite.. ran vacuum under 500 microns and charged system with R410A.. system is now running properly
St. Petersburg, FL 33712
Justin G.
Justin G. Checked in
On arrival found ADU upstairs bedroom mini split filled with nitrogen from previous company testing for leaks. Explained to client that mini split leaks are sometimes extremely small and we recommend to pull vacuum on system and refill with refrigerant. Client decided to fill unit and see how long refrigerant lasts. Filled unit back to factory specs. Unit cooling at this time. No guarantee on how long refrigerant will last in system.
St. Petersburg, FL 33701
Performed evap coil cleaning on package unit. Wiped down blower compartment. Added 2 uv systems to unit to help prevent growth. Start and test. Tax and labor included.
Performed evap coil cleaning on package unit. Wiped down blower compartment. Added 2 uv systems to unit to help prevent growth. Start and test. Tax and labor included.
Justin G.
Justin G. Checked in
Performed evap coil cleaning on package unit. Wiped down blower compartment. Added 2 uv systems to unit to help prevent growth. Start and test. Tax and labor included.
St. Petersburg, FL 33702
Ricky O.
Ricky O. Checked in
Had to program client installed Tstat. Unit is now configured and working properly
St. Petersburg, FL 33715
Ricky O.
Ricky O. Checked in
-Pump down refrigerant into condenser -Cut out old filter drier -Weld in new drier -Vacuum refrigerant lines under 500 microns -Open lines and check operation -Add refrigerant as needed
St. Petersburg, FL 33702
Ricky O.
Ricky O. Checked in
-Chemically cleaned evap coil -Replaced condensate pump and flushed drain -Vacuumed refrigerant lines and recharged system
St. Petersburg, FL 33703
Upon arrival found no high voltage coming to air handler. Had electrician come out and panel/buss bar is arking. Recommend replacing panel and breakers within. Left unit off due to potential hazard. Explained that since the air handler breakers were heating up that the heater kit could be pulling higher amps and potentially need replaced. 

Air handler noted 
-bacterial growth on blower wheel/assembly 
-heater kit potentially needing replaced (further diagnosis after panel swapped)
-3 ducts damaged from possum (6-8”)
Upon arrival found no high voltage coming to air handler. Had electrician come out and panel/buss bar is arking. Recommend replacing panel and breakers within. Left unit off due to potential hazard. Explained that since the air handler breakers were heating up that the heater kit could be pulling higher amps and potentially need replaced. 

Air handler noted 
-bacterial growth on blower wheel/assembly 
-heater kit potentially needing replaced (further diagnosis after panel swapped)
-3 ducts damaged from possum (6-8”)
Nathan A.
Nathan A. Checked in
Upon arrival found no high voltage coming to air handler. Had electrician come out and panel/buss bar is arking. Recommend replacing panel and breakers within. Left unit off due to potential hazard. Explained that since the air handler breakers were heating up that the heater kit could be pulling higher amps and potentially need replaced. Air handler noted -bacterial growth on blower wheel/assembly -heater kit potentially needing replaced (further diagnosis after panel swapped) -3 ducts damaged from possum (6-8”)
St. Petersburg, FL 33704
Install 2 GFCI plug and cover plates 

Reinstalled conduit for water heater after seeing connector was not properly installed and presupposed conduit on wall 

Checked oven and dyer outlets to verify they were working and they had proper voltages 
Outlets that were not working just tripped the breaker and someone had already reset it double checked with meter to verify proper voltages
Install 2 GFCI plug and cover plates 

Reinstalled conduit for water heater after seeing connector was not properly installed and presupposed conduit on wall 

Checked oven and dyer outlets to verify they were working and they had proper voltages 
Outlets that were not working just tripped the breaker and someone had already reset it double checked with meter to verify proper voltages
Griffin K.
Griffin K. Checked in
Install 2 GFCI plug and cover plates Reinstalled conduit for water heater after seeing connector was not properly installed and presupposed conduit on wall Checked oven and dyer outlets to verify they were working and they had proper voltages Outlets that were not working just tripped the breaker and someone had already reset it double checked with meter to verify proper voltages
St. Petersburg, FL 33702
On arrival found upstairs unit not cooling due to breaker being off for condenser. Turned on power and tested. Electrical checked good. Pressures good. Temp split good. Unit is 15 years old in poor condition. Client declined any recommended repairs and will ride out existing unit as is until it fails. Units cooling.
On arrival found upstairs unit not cooling due to breaker being off for condenser. Turned on power and tested. Electrical checked good. Pressures good. Temp split good. Unit is 15 years old in poor condition. Client declined any recommended repairs and will ride out existing unit as is until it fails. Units cooling.
Justin G.
Justin G. Checked in
On arrival found upstairs unit not cooling due to breaker being off for condenser. Turned on power and tested. Electrical checked good. Pressures good. Temp split good. Unit is 15 years old in poor condition. Client declined any recommended repairs and will ride out existing unit as is until it fails. Units cooling.
St. Petersburg, FL 33701
Performed Maitenences on systems. Cleaned/treated drain lines and primary drain pans. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switchs functionality. Checked amp draw on compressors. Checked amp draw on fan motors. Checked capacitors are within factory range. Condenser #2 had a weak capacitor. Replaced this capacitor. Made sure all connections are tight. Systems are cooling with 20° temperature splits at this time. Verified systems heat properly. 
Blower compartments on both systems have microbial growth and recommending cleaning/sanitation with UV systems installed. 
Quotes sent. 
Air filters are dirty and need to be replaced especially upstairs. Downstairs system air filter is not as bad as notified client that impacted air filters can damage blower motors.
Performed Maitenences on systems. Cleaned/treated drain lines and primary drain pans. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switchs functionality. Checked amp draw on compressors. Checked amp draw on fan motors. Checked capacitors are within factory range. Condenser #2 had a weak capacitor. Replaced this capacitor. Made sure all connections are tight. Systems are cooling with 20° temperature splits at this time. Verified systems heat properly. 
Blower compartments on both systems have microbial growth and recommending cleaning/sanitation with UV systems installed. 
Quotes sent. 
Air filters are dirty and need to be replaced especially upstairs. Downstairs system air filter is not as bad as notified client that impacted air filters can damage blower motors.
Michael A.
Michael A. Checked in
Performed Maitenences on systems. Cleaned/treated drain lines and primary drain pans. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switchs functionality. Checked amp draw on compressors. Checked amp draw on fan motors. Checked capacitors are within factory range. Condenser #2 had a weak capacitor. Replaced this capacitor. Made sure all connections are tight. Systems are cooling with 20° temperature splits at this time. Verified systems heat properly. Blower compartments on both systems have microbial growth and recommending cleaning/sanitation with UV systems installed. Quotes sent. Air filters are dirty and need to be replaced especially upstairs. Downstairs system air filter is not as bad as notified client that impacted air filters can damage blower motors.
St. Petersburg, FL 33703
Return to replace outdoor fan motor and verify further operations. 

Replaced and wired in new outdoor condenser motor. Verified system is cooling and working within manufacture specifications
Return to replace outdoor fan motor and verify further operations. 

Replaced and wired in new outdoor condenser motor. Verified system is cooling and working within manufacture specifications
Nathan A.
Nathan A. Checked in
Return to replace outdoor fan motor and verify further operations. Replaced and wired in new outdoor condenser motor. Verified system is cooling and working within manufacture specifications
St. Petersburg, FL 33705
On arrival found unit not cooling due to bad capacitor. Replaced cap and tested. Found u it low on refrigerant with heavily corroded coil. Client decided to move forward with full system replacement. Unit is cooling to the best of its ability at this time.
On arrival found unit not cooling due to bad capacitor. Replaced cap and tested. Found u it low on refrigerant with heavily corroded coil. Client decided to move forward with full system replacement. Unit is cooling to the best of its ability at this time.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to bad capacitor. Replaced cap and tested. Found u it low on refrigerant with heavily corroded coil. Client decided to move forward with full system replacement. Unit is cooling to the best of its ability at this time.
St. Petersburg, FL 33704
Performed Tune up on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with an 18° temperature split at this time.

Duct work is in A+ condition

System does not have a UV light inside air handler to prevent microbial growth. 
Quote sent for UV installation. 
Membership Maitenence plan quote sent.
Performed Tune up on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with an 18° temperature split at this time.

Duct work is in A+ condition

System does not have a UV light inside air handler to prevent microbial growth. 
Quote sent for UV installation. 
Membership Maitenence plan quote sent.
Michael A.
Michael A. Checked in
Performed Tune up on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with an 18° temperature split at this time. Duct work is in A+ condition System does not have a UV light inside air handler to prevent microbial growth. Quote sent for UV installation. Membership Maitenence plan quote sent.
St. Petersburg, FL 33714
Kyle K.
Kyle K. Checked in
Remove mini split -Remove head unit -Remove outdoor unit -Remove dain and line set -Remove line cover -Spray foam penetration point -Cap electrical **NOTE: They want to keep mini split and materials so leave in garage
St. Petersburg, FL 33713
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Drain line very clogged, broke free with nitrogen and added a union joint for future accessibility. Installed 1ft of new drain insulation complimentary. No P trap on drain line. Installed new P trap. Cleaned condenser coils. Evaporator coils are clean. Very hard to get the Doors off the unit. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is not within factory range. Replaced capacitor.  Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.

Quote sent and accepted for all duct work repairs. Duct work has many connection issues, supply plenum is dumping air out of the top, duct runs are not strapped up, duct runs are burried in blown in insulation, boots and not sealed to the ceiling and are causing growth to grow on the ceiling. System does not have UV system. 
Re
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Drain line very clogged, broke free with nitrogen and added a union joint for future accessibility. Installed 1ft of new drain insulation complimentary. No P trap on drain line. Installed new P trap. Cleaned condenser coils. Evaporator coils are clean. Very hard to get the Doors off the unit. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is not within factory range. Replaced capacitor.  Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.

Quote sent and accepted for all duct work repairs. Duct work has many connection issues, supply plenum is dumping air out of the top, duct runs are not strapped up, duct runs are burried in blown in insulation, boots and not sealed to the ceiling and are causing growth to grow on the ceiling. System does not have UV system. 
Re
Michael A.
Michael A. Checked in
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Drain line very clogged, broke free with nitrogen and added a union joint for future accessibility. Installed 1ft of new drain insulation complimentary. No P trap on drain line. Installed new P trap. Cleaned condenser coils. Evaporator coils are clean. Very hard to get the Doors off the unit. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is not within factory range. Replaced capacitor. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. Quote sent and accepted for all duct work repairs. Duct work has many connection issues, supply plenum is dumping air out of the top, duct runs are not strapped up, duct runs are burried in blown in insulation, boots and not sealed to the ceiling and are causing growth to grow on the ceiling. System does not have UV system. Re
St. Petersburg, FL 33710
On arrival found unit not running due to blown fuse caused by corroded thermostat wires. Repaired wires and replaced worn contactor. Start and test. Unit functions in heating and cooling modes. Found supply plenum detached from air handler and ducts not strapped and seal properly.  Client declined air bros to make repairs for ducts at this time.
On arrival found unit not running due to blown fuse caused by corroded thermostat wires. Repaired wires and replaced worn contactor. Start and test. Unit functions in heating and cooling modes. Found supply plenum detached from air handler and ducts not strapped and seal properly.  Client declined air bros to make repairs for ducts at this time.
Justin G.
Justin G. Checked in
On arrival found unit not running due to blown fuse caused by corroded thermostat wires. Repaired wires and replaced worn contactor. Start and test. Unit functions in heating and cooling modes. Found supply plenum detached from air handler and ducts not strapped and seal properly. Client declined air bros to make repairs for ducts at this time.
St. Petersburg, FL 33702
Performed maintenance on system. Cleared pan and drain. Added chemical to pan to help prevent growth. Pressures good. Found weak capacitor and replaced. Electrical checked good. Added primary float switch to unit to prevent leaking water in attic. Rinsed condenser coils. Unit operating properly at this time.
Performed maintenance on system. Cleared pan and drain. Added chemical to pan to help prevent growth. Pressures good. Found weak capacitor and replaced. Electrical checked good. Added primary float switch to unit to prevent leaking water in attic. Rinsed condenser coils. Unit operating properly at this time.
Justin G.
Justin G. Checked in
Performed maintenance on system. Cleared pan and drain. Added chemical to pan to help prevent growth. Pressures good. Found weak capacitor and replaced. Electrical checked good. Added primary float switch to unit to prevent leaking water in attic. Rinsed condenser coils. Unit operating properly at this time.
St. Petersburg, FL 33713
How do I know if my AC needs repair or full replacement?

Our technicians inspect the full system — age, refrigerant type, corrosion, and repair history — and give you an honest recommendation. If a repair makes sense, we'll fix it. If the unit is beyond its useful life, we'll walk you through replacement options with no pressure.

Are your technicians background-checked and licensed?

Yes. Every Air Bros technician is background-checked, factory-trained, and works under our state HVAC license (#CAC1820499) and electrical license (#EC13015085).

What parts of St. Petersburg do you serve?

We serve all of St. Petersburg, including Downtown, Historic Kenwood, Old Northeast, Snell Isle, Crescent Lake, Shore Acres, and Coquina Key, plus Seminole, Largo, Pinellas Park, and the surrounding beach communities.

Do you offer same-day AC repair in St. Petersburg?

Yes. We offer 24/7 emergency AC repair with same-day service throughout St. Petersburg and the surrounding Pinellas County area.

Is Air Bros a local St. Petersburg company, or a franchise?

Air Bros is 100% locally owned and operated, headquartered in the Shore Acres neighborhood of St. Petersburg. We're not a franchise — every technician is a direct employee, not a subcontractor.

Contact the Bros You Know Today!

Gravity Forms Pagination Must be Steps