The Best AC Repair in St. Petersburg, FL — From Technicians Your Neighbors Already Trust

When your AC quits in the middle of a St. Pete summer, you don't want a stranger in an unmarked van. You want a technician your neighbors already know and trust. Air Bros Air Conditioning & Electrical has been fixing air conditioners in St. Petersburg since 2020, but our roots run deeper — founder Ricky Orta grew up learning the trade from his father and has been a licensed HVAC contractor since 2006. That local, hands-on experience is why homeowners from Historic Kenwood to Snell Isle call us the best AC repair company in St. Petersburg.

We're headquartered right here in the Shore Acres neighborhood, so when you call, you're not routed to a call center — you're talking to the same local team that services your street.

Call us at 727-217-6148 or contact us online today for all of your HVAC, indoor air quality and electrical needs.

Meet the technicians who service St. Petersburg

What to expect when we show up

Calling a repair company you've never used before shouldn't feel like a gamble. Here's exactly how an Air Bros service call goes, every time.

You'll get a heads-up before we arrive, then a uniformed technician in a marked Air Bros vehicle shows up in the window we promised. We diagnose the whole system — not just the obvious symptom — then explain what we found and what your options are before any work starts. You approve the price up front, we make the repair, and we don't leave until we've confirmed the system is cooling the way it should.

Every technician is a background-checked, drug-tested Air Bros employee — never a subcontractor — and each one is trained to service every major AC and heat pump brand. It's the kind of consistency you can only get from a local team that answers to its own name.

And if something isn't right? Our 100% satisfaction guarantee means we make it right.

Signs you need AC repair

St. Petersburg's heat and humidity push air conditioners harder than almost anywhere else in the country. Call for AC repair if you notice:

  • Warm air blowing from vents, or the system running constantly without cooling
  • Water pooling around your air handler (a common issue in St. Pete's older homes with attic-run drain lines)
  • Musty odors or visible mold near vents — a sign of a clogged condensate line or dirty coil
  • Rising humidity indoors despite the AC running
  • Short cycling, tripped breakers, or a system that won't turn on at all

Our technicians diagnose the full system on every call — refrigerant charge, temperature split, electrical connections, and drain line — so you get a real fix, not a temporary patch.

Comprehensive HVAC Services in St. Petersburg

We offer a full range of heating and cooling services to keep your St. Petersburg, FL, home comfortable year-round:

  • Air Conditioning: From AC repair and AC installation to routine maintenance, we ensure your cooling system keeps you comfortable during those hot Florida summers. We offer same-day service for AC emergencies, so you never have to suffer in the heat.
  • Heating: Stay warm and cozy in the winter with our comprehensive heating services. We repair and install all types of heating systems, including furnaces and heat pumps, and offer preventative maintenance to keep your system running efficiently.
  • Indoor Air Quality: Improve your indoor air quality with our dehumidifier and UV light installation services. We'll help you control excess humidity and eliminate airborne contaminants, creating a healthier home environment.
  • Ductwork: Ensure optimal airflow and energy efficiency with our ductwork repair and installation services. We can address leaks and damage, and design a system that's perfect for your home.
  • Pool Heater Services: Extend your swim season with our pool heater installation and repair services.
  • Electrical Services: From outlet and switch replacements to ceiling fan installations to whole-house surge protector installations, we have the experts to handle your electrical service needs.

Our experienced technicians are skilled in all aspects of HVAC service and are dedicated to providing top-quality workmanship and customer care.

Why Choose Air Bros?

  • Local Expertise: We understand the unique climate challenges of St. Petersburg.
  • Fast and Reliable Service: We offer same-day service for AC emergencies and prioritize prompt service for all your HVAC needs.
  • Experienced Technicians: Our team is highly trained and experienced in all aspects of HVAC service.
  • Upfront Pricing: We provide transparent pricing with no hidden costs.
  • Customer Satisfaction Guaranteed: Your comfort and satisfaction are our top priorities.

Contact Air Bros Today!

Whether you need emergency AC repair, a new heating system installation, or any other HVAC service, Air Bros is here to help. Contact us today for a free consultation or to schedule a service appointment. We're proud to be your trusted HVAC partner in St. Petersburg!

Call us at 727-217-6148 or contact us online today!

Recent Jobs and Reviews in St. Petersburg, FL

St. Petersburg, FL at a glance

Air Bros Air Conditioning & Electrical has completed 25 jobs in St. Petersburg, FL in February 2026.

The most recent job was on February 13, 2026.

Air Bros Air Conditioning & Electrical has completed 1,919 jobs in St. Petersburg, FL in the last 12 months. The first job there was in December 2024.

Job Locations and Reviews

Griffin K.
Griffin K. Checked in
Run 2 new receptacles on both sides of the garage for fence lighting Cut into existing circuits in garage attic space Surface mount receptacle boxes near the top of the fence
St. Petersburg, FL 33704
Justin G.
Justin G. Checked in
Found mini split not cooling for mother in law suite due to improper setting on thermostat. Showed client how to operate remote. Unit cooling.
St. Petersburg, FL 33713
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. There is no safety float switch currently installed on system. System is at risk of flooding water if drain line backs up. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.
Breaker sizes on air handler and condenser are wrong and are not up to code. Air handler has a 45 amp and requires a 35. Condenser has a 45 and requires a 40. 
Air handler blower compartment has severe growth present. 
Recommending blower wheel pull and clean with the installation of a new UV system to prevent future growth after cleaning. 
Recommending installing a Safety float switch for the drain pan. 
Quotes sent to client. 
Clients availability next week W-F 10-12.
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. There is no safety float switch currently installed on system. System is at risk of flooding water if drain line backs up. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.
Breaker sizes on air handler and condenser are wrong and are not up to code. Air handler has a 45 amp and requires a 35. Condenser has a 45 and requires a 40. 
Air handler blower compartment has severe growth present. 
Recommending blower wheel pull and clean with the installation of a new UV system to prevent future growth after cleaning. 
Recommending installing a Safety float switch for the drain pan. 
Quotes sent to client. 
Clients availability next week W-F 10-12.
Michael A.
Michael A. Checked in
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. There is no safety float switch currently installed on system. System is at risk of flooding water if drain line backs up. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. Breaker sizes on air handler and condenser are wrong and are not up to code. Air handler has a 45 amp and requires a 35. Condenser has a 45 and requires a 40. Air handler blower compartment has severe growth present. Recommending blower wheel pull and clean with the installation of a new UV system to prevent future growth after cleaning. Recommending installing a Safety float switch for the drain pan. Quotes sent to client. Clients availability next week W-F 10-12.
St. Petersburg, FL 33702
Justin G.
Justin G. Checked in
On arrival found unit not operating due to corroded common wire in air handler. Made new connection. Start and test. Performed maintenance on system. Electrical checked good. Blower and coil clean. Filter clean.
St. Petersburg, FL 33704
Justin G.
Justin G. Checked in
Wired unit properly for heat pump.
St. Petersburg, FL 33703
On arrival found unit not heating due to broken heater kit. Will submit estimate for new heater kit and system replacement due to age and condition. Unit cools only at this time.
On arrival found unit not heating due to broken heater kit. Will submit estimate for new heater kit and system replacement due to age and condition. Unit cools only at this time.
Justin G.
Justin G. Checked in
On arrival found unit not heating due to broken heater kit. Will submit estimate for new heater kit and system replacement due to age and condition. Unit cools only at this time.
St. Petersburg, FL 33713
Replaced furnace motor and sealed interior plenum with mastic. Verified system operations.
Replaced furnace motor and sealed interior plenum with mastic. Verified system operations.
Nathan A.
Nathan A. Checked in
Replaced furnace motor and sealed interior plenum with mastic. Verified system operations.
St. Petersburg, FL 33703
Performed maintenance on 2 systems. Cleaned coils and filters on mini split. Cleared pan and drain. Pressures good. Temp split good. Recommend to client to leave unit on to help with humidity issues. 
Main system cleared pan and drain. Added chemical to help prevent growth. Replaced worn contactor and capacitor. Rinsed condenser coil. Pressures good and temp split good. Both units operating properly at this time.
Performed maintenance on 2 systems. Cleaned coils and filters on mini split. Cleared pan and drain. Pressures good. Temp split good. Recommend to client to leave unit on to help with humidity issues. 
Main system cleared pan and drain. Added chemical to help prevent growth. Replaced worn contactor and capacitor. Rinsed condenser coil. Pressures good and temp split good. Both units operating properly at this time.
Justin G.
Justin G. Checked in
Performed maintenance on 2 systems. Cleaned coils and filters on mini split. Cleared pan and drain. Pressures good. Temp split good. Recommend to client to leave unit on to help with humidity issues. Main system cleared pan and drain. Added chemical to help prevent growth. Replaced worn contactor and capacitor. Rinsed condenser coil. Pressures good and temp split good. Both units operating properly at this time.
St. Petersburg, FL 33703
On arrival found front mini split not cooling due to low refrigerant error code. Added refrigerant to system to bring pressures up and performed leak search on system. Found all 3 evap coils leaking and flare connections outside. Unit is not under warranty. Due to age and condition we recommend to perform full system replacement. Unit does cool and heat at this time to the best of its ability. Will submit estimate for system replacement.
On arrival found front mini split not cooling due to low refrigerant error code. Added refrigerant to system to bring pressures up and performed leak search on system. Found all 3 evap coils leaking and flare connections outside. Unit is not under warranty. Due to age and condition we recommend to perform full system replacement. Unit does cool and heat at this time to the best of its ability. Will submit estimate for system replacement.
Justin G.
Justin G. Checked in
On arrival found front mini split not cooling due to low refrigerant error code. Added refrigerant to system to bring pressures up and performed leak search on system. Found all 3 evap coils leaking and flare connections outside. Unit is not under warranty. Due to age and condition we recommend to perform full system replacement. Unit does cool and heat at this time to the best of its ability. Will submit estimate for system replacement.
St. Petersburg, FL 33702
Replace ceiling fan with customer supplied light fixture and replace switch
Replace ceiling fan with customer supplied light fixture and replace switch
Griffin K.
Griffin K. Checked in
Replace ceiling fan with customer supplied light fixture and replace switch
St. Petersburg, FL 33704
Full Duct Replacement 
Install Attic Fan 

Unable to test attic fan due to temperature in attic being to low asked customer to check this afternoon if it comes on
Full Duct Replacement 
Install Attic Fan 

Unable to test attic fan due to temperature in attic being to low asked customer to check this afternoon if it comes on
Martin W.
Martin W. Checked in
Full Duct Replacement Install Attic Fan Unable to test attic fan due to temperature in attic being to low asked customer to check this afternoon if it comes on
St. Petersburg, FL 33705
Outdoor disconnect and electrical bypassed. Fittings failed and shorted out high voltage and burnt up disconnect. Will need to replace whip and disconnect for further diagnosis. 

Replaced outdoor insulation and spliced new wire connections 

Verified system operations 

Return to install surge
Outdoor disconnect and electrical bypassed. Fittings failed and shorted out high voltage and burnt up disconnect. Will need to replace whip and disconnect for further diagnosis. 

Replaced outdoor insulation and spliced new wire connections 

Verified system operations 

Return to install surge
Nathan A.
Nathan A. Checked in
Outdoor disconnect and electrical bypassed. Fittings failed and shorted out high voltage and burnt up disconnect. Will need to replace whip and disconnect for further diagnosis. Replaced outdoor insulation and spliced new wire connections Verified system operations Return to install surge
St. Petersburg, FL 33704
St. Petersburg, FL - Remove AFCI ply and install weather resistant GFCI plug for code compliance outlet had no equipment ground
Griffin K.
Griffin K. Checked in
Remove AFCI ply and install weather resistant GFCI plug for code compliance outlet had no equipment ground
St. Petersburg, FL 33704
Found the tabs broken off on filter back return grill. Temporarily fixed it with screws and short metal tabs to keep filtered door up. Client may be interested in having a new filter back return grill installed.
Found the tabs broken off on filter back return grill. Temporarily fixed it with screws and short metal tabs to keep filtered door up. Client may be interested in having a new filter back return grill installed.
Michael A.
Michael A. Checked in
Found the tabs broken off on filter back return grill. Temporarily fixed it with screws and short metal tabs to keep filtered door up. Client may be interested in having a new filter back return grill installed.
St. Petersburg, FL 33714
Upon my inspection, found 10kw heating kit is only pulling 20 amps and there are burnt up wires. This heating kit is no longer safe to use and will not work properly. Also found a weak capacitor on the condenser unit and smushed coils on the condenser. These are all deficiencies with the 20 year old system. 
Recommending a Maitenence plan for both systems upstairs and downstairs. Systems appear to have not been maintained properly at this time. 

** we do not recommend running the heat on this system as it is a safety hazard. 

System issues:
Bad capacitor
Bad heating kit
Condenser coils are completely smushed on the back side. 
Rusted contactar
Quote sent for bare minimum repairs. 
Quote sent for system replacement.
Upon my inspection, found 10kw heating kit is only pulling 20 amps and there are burnt up wires. This heating kit is no longer safe to use and will not work properly. Also found a weak capacitor on the condenser unit and smushed coils on the condenser. These are all deficiencies with the 20 year old system. 
Recommending a Maitenence plan for both systems upstairs and downstairs. Systems appear to have not been maintained properly at this time. 

** we do not recommend running the heat on this system as it is a safety hazard. 

System issues:
Bad capacitor
Bad heating kit
Condenser coils are completely smushed on the back side. 
Rusted contactar
Quote sent for bare minimum repairs. 
Quote sent for system replacement.
Michael A.
Michael A. Checked in
Upon my inspection, found 10kw heating kit is only pulling 20 amps and there are burnt up wires. This heating kit is no longer safe to use and will not work properly. Also found a weak capacitor on the condenser unit and smushed coils on the condenser. These are all deficiencies with the 20 year old system. Recommending a Maitenence plan for both systems upstairs and downstairs. Systems appear to have not been maintained properly at this time. ** we do not recommend running the heat on this system as it is a safety hazard. System issues: Bad capacitor Bad heating kit Condenser coils are completely smushed on the back side. Rusted contactar Quote sent for bare minimum repairs. Quote sent for system replacement.
St. Petersburg, FL 33704
Griffin K.
Griffin K. Checked in
Install customer supplied ceiling fan Trouble shot garage lights they had bad smart switches installed standard switches
St. Petersburg, FL 33703
Home owners state when running heat the outdoor unit would short cycle and begin to freeze up. Stated indoor started to blow tempid air. 

Potential outdoor piston clogged 

Found system reading out of specs subcool of 10. Charged system back to specs. Will monitor if potential leak.
Home owners state when running heat the outdoor unit would short cycle and begin to freeze up. Stated indoor started to blow tempid air. 

Potential outdoor piston clogged 

Found system reading out of specs subcool of 10. Charged system back to specs. Will monitor if potential leak.
Nathan A.
Nathan A. Checked in
Home owners state when running heat the outdoor unit would short cycle and begin to freeze up. Stated indoor started to blow tempid air. Potential outdoor piston clogged Found system reading out of specs subcool of 10. Charged system back to specs. Will monitor if potential leak.
St. Petersburg, FL 33704
Full System Tuneup 

Non Permitted Install 

Home owner also had previous/current rodent issue

Air Handler Notes 
-no primary safety overflow switch 
-secondary pan no capped 
-drain line lacking insulation 
-bacterial growth accumulating inside air handler (blower wheel)
-plenums not sealed properly 

Outdoor Unit Notes 
-no hurricane tie down straps 
-outdoor disconnect broken

Ducting Notes 
-damaged 7” flex 
-damaged main trunk flex 
-ducts not sealed properly 

Refrigerant lines not sized properly for system 

Home is also lacking insulation 

Bathroom fan on operable (vented in attic/exposed high voltage) home owner states it’s been disconnected
Full System Tuneup 

Non Permitted Install 

Home owner also had previous/current rodent issue

Air Handler Notes 
-no primary safety overflow switch 
-secondary pan no capped 
-drain line lacking insulation 
-bacterial growth accumulating inside air handler (blower wheel)
-plenums not sealed properly 

Outdoor Unit Notes 
-no hurricane tie down straps 
-outdoor disconnect broken

Ducting Notes 
-damaged 7” flex 
-damaged main trunk flex 
-ducts not sealed properly 

Refrigerant lines not sized properly for system 

Home is also lacking insulation 

Bathroom fan on operable (vented in attic/exposed high voltage) home owner states it’s been disconnected
Nathan A.
Nathan A. Checked in
Full System Tuneup Non Permitted Install Home owner also had previous/current rodent issue Air Handler Notes -no primary safety overflow switch -secondary pan no capped -drain line lacking insulation -bacterial growth accumulating inside air handler (blower wheel) -plenums not sealed properly Outdoor Unit Notes -no hurricane tie down straps -outdoor disconnect broken Ducting Notes -damaged 7” flex -damaged main trunk flex -ducts not sealed properly Refrigerant lines not sized properly for system Home is also lacking insulation Bathroom fan on operable (vented in attic/exposed high voltage) home owner states it’s been disconnected
St. Petersburg, FL 33703
Ruud 3 ton 15 seer heat pump
2 stage system
10 year parts warranty
3 years labor warrantyI
-Hurricane pad
-Hurricane tiedowns
-UV rated armorflex
-Electrical whip
-Thermostat 
-New plenums
-Seal around return grille with ductboard
-Drain pan
-Safeties
-Flush drain
-Insulate exposed piping
-Line drier
-Vacuum lines under 500 microns
-Start up and verify operations 

**0% interest financing available**
Ruud 3 ton 15 seer heat pump
2 stage system
10 year parts warranty
3 years labor warrantyI
-Hurricane pad
-Hurricane tiedowns
-UV rated armorflex
-Electrical whip
-Thermostat 
-New plenums
-Seal around return grille with ductboard
-Drain pan
-Safeties
-Flush drain
-Insulate exposed piping
-Line drier
-Vacuum lines under 500 microns
-Start up and verify operations 

**0% interest financing available**
Kyle K.
Kyle K. Checked in
Ruud 3 ton 15 seer heat pump 2 stage system 10 year parts warranty 3 years labor warrantyI -Hurricane pad -Hurricane tiedowns -UV rated armorflex -Electrical whip -Thermostat -New plenums -Seal around return grille with ductboard -Drain pan -Safeties -Flush drain -Insulate exposed piping -Line drier -Vacuum lines under 500 microns -Start up and verify operations **0% interest financing available**
St. Petersburg, FL 33704
Justin G.
Justin G. Checked in
Unit showed f5 error code. Explained to client that pool heaters struggle to heat pools when temps are below 50*. Recommend to replace heat pump with gas pool heater to allow client to heat all year. Unit is operating at this time.
St. Petersburg, FL 33705
Complimentary duct sanitation
Complimentary duct sanitation
Martin W.
Martin W. Checked in
Complimentary duct sanitation
St. Petersburg, FL 33712
Client states unit not turning on previously. Inspected unit for operation. Tested heating and cooling modes. Temp split in spec. Amp draws on heater good. Blower capacitor in spec. Pressures good. Temp split in cooling 20*. Float switch dry and operational. No issues found today. Unit is heating and cooling properly at this time.
Client states unit not turning on previously. Inspected unit for operation. Tested heating and cooling modes. Temp split in spec. Amp draws on heater good. Blower capacitor in spec. Pressures good. Temp split in cooling 20*. Float switch dry and operational. No issues found today. Unit is heating and cooling properly at this time.
Justin G.
Justin G. Checked in
Client states unit not turning on previously. Inspected unit for operation. Tested heating and cooling modes. Temp split in spec. Amp draws on heater good. Blower capacitor in spec. Pressures good. Temp split in cooling 20*. Float switch dry and operational. No issues found today. Unit is heating and cooling properly at this time.
St. Petersburg, FL 33702
Performed maintenance on two systems. Cleaned and treated drain lines and primary drain pans. Inspected blower motors. Checked fan motor capacitors. Found main living room area AC fan capacitor was weak and found bedroom fan capacitor weak. Replaced capacitors. Fan motor for living room area has oil residue and is amping at 1.46 amps with a rating of 1.45. Notified client that we will have to watch this fan motor and it is at risk of possible failure. System heating at this time. 
Changed client provided air filters
Performed maintenance on two systems. Cleaned and treated drain lines and primary drain pans. Inspected blower motors. Checked fan motor capacitors. Found main living room area AC fan capacitor was weak and found bedroom fan capacitor weak. Replaced capacitors. Fan motor for living room area has oil residue and is amping at 1.46 amps with a rating of 1.45. Notified client that we will have to watch this fan motor and it is at risk of possible failure. System heating at this time. 
Changed client provided air filters
Michael A.
Michael A. Checked in
Performed maintenance on two systems. Cleaned and treated drain lines and primary drain pans. Inspected blower motors. Checked fan motor capacitors. Found main living room area AC fan capacitor was weak and found bedroom fan capacitor weak. Replaced capacitors. Fan motor for living room area has oil residue and is amping at 1.46 amps with a rating of 1.45. Notified client that we will have to watch this fan motor and it is at risk of possible failure. System heating at this time. Changed client provided air filters
St. Petersburg, FL 33701
Pull and clean blower. Clean in place evap coil. Perform maintenance on system. Tax and labor included.
Pull and clean blower. Clean in place evap coil. Perform maintenance on system. Tax and labor included.
Justin G.
Justin G. Checked in
Pull and clean blower. Clean in place evap coil. Perform maintenance on system. Tax and labor included.
St. Petersburg, FL 33708
Sound issue client was hearing is due to system going into defrost mode and the reversing valve releasing refrigerant. No problems with this noise. 
Client signed up for Maitenence plan. Performed first Maitenence on system. Vacuumed drain line and cleaned condens and coils on this first quick Maitenence. 
Condenser unit was flooded in last hurricane. Found corroded contactar, capacitor, and disconnect at the condenser unit. Replaced all and made new connections. System is over amping on start up pulling 83 amps with a max rating of 72.5. Recommended a soft start kit. 
Client would like to keep this system running as long as possible. 
Scope of work performed
- Replace condenser disconnect
- Replace contactar
- Replace capacitor
- Make new connections to these components. 
* No breakdown guarantee due to Unit hurricane flood*
Sound issue client was hearing is due to system going into defrost mode and the reversing valve releasing refrigerant. No problems with this noise. 
Client signed up for Maitenence plan. Performed first Maitenence on system. Vacuumed drain line and cleaned condens and coils on this first quick Maitenence. 
Condenser unit was flooded in last hurricane. Found corroded contactar, capacitor, and disconnect at the condenser unit. Replaced all and made new connections. System is over amping on start up pulling 83 amps with a max rating of 72.5. Recommended a soft start kit. 
Client would like to keep this system running as long as possible. 
Scope of work performed
- Replace condenser disconnect
- Replace contactar
- Replace capacitor
- Make new connections to these components. 
* No breakdown guarantee due to Unit hurricane flood*
Michael A.
Michael A. Checked in
Sound issue client was hearing is due to system going into defrost mode and the reversing valve releasing refrigerant. No problems with this noise. Client signed up for Maitenence plan. Performed first Maitenence on system. Vacuumed drain line and cleaned condens and coils on this first quick Maitenence. Condenser unit was flooded in last hurricane. Found corroded contactar, capacitor, and disconnect at the condenser unit. Replaced all and made new connections. System is over amping on start up pulling 83 amps with a max rating of 72.5. Recommended a soft start kit. Client would like to keep this system running as long as possible. Scope of work performed - Replace condenser disconnect - Replace contactar - Replace capacitor - Make new connections to these components. * No breakdown guarantee due to Unit hurricane flood*
St. Petersburg, FL 33703
How do I know if my AC needs repair or full replacement?

Our technicians inspect the full system — age, refrigerant type, corrosion, and repair history — and give you an honest recommendation. If a repair makes sense, we'll fix it. If the unit is beyond its useful life, we'll walk you through replacement options with no pressure.

Are your technicians background-checked and licensed?

Yes. Every Air Bros technician is background-checked, factory-trained, and works under our state HVAC license (#CAC1820499) and electrical license (#EC13015085).

What parts of St. Petersburg do you serve?

We serve all of St. Petersburg, including Downtown, Historic Kenwood, Old Northeast, Snell Isle, Crescent Lake, Shore Acres, and Coquina Key, plus Seminole, Largo, Pinellas Park, and the surrounding beach communities.

Do you offer same-day AC repair in St. Petersburg?

Yes. We offer 24/7 emergency AC repair with same-day service throughout St. Petersburg and the surrounding Pinellas County area.

Is Air Bros a local St. Petersburg company, or a franchise?

Air Bros is 100% locally owned and operated, headquartered in the Shore Acres neighborhood of St. Petersburg. We're not a franchise — every technician is a direct employee, not a subcontractor.

Contact the Bros You Know Today!

Gravity Forms Pagination Must be Steps