The Best AC Repair in St. Petersburg, FL — From Technicians Your Neighbors Already Trust

When your AC quits in the middle of a St. Pete summer, you don't want a stranger in an unmarked van. You want a technician your neighbors already know and trust. Air Bros Air Conditioning & Electrical has been fixing air conditioners in St. Petersburg since 2020, but our roots run deeper — founder Ricky Orta grew up learning the trade from his father and has been a licensed HVAC contractor since 2006. That local, hands-on experience is why homeowners from Historic Kenwood to Snell Isle call us the best AC repair company in St. Petersburg.

We're headquartered right here in the Shore Acres neighborhood, so when you call, you're not routed to a call center — you're talking to the same local team that services your street.

Call us at 727-217-6148 or contact us online today for all of your HVAC, indoor air quality and electrical needs.

Meet the technicians who service St. Petersburg

What to expect when we show up

Calling a repair company you've never used before shouldn't feel like a gamble. Here's exactly how an Air Bros service call goes, every time.

You'll get a heads-up before we arrive, then a uniformed technician in a marked Air Bros vehicle shows up in the window we promised. We diagnose the whole system — not just the obvious symptom — then explain what we found and what your options are before any work starts. You approve the price up front, we make the repair, and we don't leave until we've confirmed the system is cooling the way it should.

Every technician is a background-checked, drug-tested Air Bros employee — never a subcontractor — and each one is trained to service every major AC and heat pump brand. It's the kind of consistency you can only get from a local team that answers to its own name.

And if something isn't right? Our 100% satisfaction guarantee means we make it right.

Signs you need AC repair

St. Petersburg's heat and humidity push air conditioners harder than almost anywhere else in the country. Call for AC repair if you notice:

  • Warm air blowing from vents, or the system running constantly without cooling
  • Water pooling around your air handler (a common issue in St. Pete's older homes with attic-run drain lines)
  • Musty odors or visible mold near vents — a sign of a clogged condensate line or dirty coil
  • Rising humidity indoors despite the AC running
  • Short cycling, tripped breakers, or a system that won't turn on at all

Our technicians diagnose the full system on every call — refrigerant charge, temperature split, electrical connections, and drain line — so you get a real fix, not a temporary patch.

Comprehensive HVAC Services in St. Petersburg

We offer a full range of heating and cooling services to keep your St. Petersburg, FL, home comfortable year-round:

  • Air Conditioning: From AC repair and AC installation to routine maintenance, we ensure your cooling system keeps you comfortable during those hot Florida summers. We offer same-day service for AC emergencies, so you never have to suffer in the heat.
  • Heating: Stay warm and cozy in the winter with our comprehensive heating services. We repair and install all types of heating systems, including furnaces and heat pumps, and offer preventative maintenance to keep your system running efficiently.
  • Indoor Air Quality: Improve your indoor air quality with our dehumidifier and UV light installation services. We'll help you control excess humidity and eliminate airborne contaminants, creating a healthier home environment.
  • Ductwork: Ensure optimal airflow and energy efficiency with our ductwork repair and installation services. We can address leaks and damage, and design a system that's perfect for your home.
  • Pool Heater Services: Extend your swim season with our pool heater installation and repair services.
  • Electrical Services: From outlet and switch replacements to ceiling fan installations to whole-house surge protector installations, we have the experts to handle your electrical service needs.

Our experienced technicians are skilled in all aspects of HVAC service and are dedicated to providing top-quality workmanship and customer care.

Why Choose Air Bros?

  • Local Expertise: We understand the unique climate challenges of St. Petersburg.
  • Fast and Reliable Service: We offer same-day service for AC emergencies and prioritize prompt service for all your HVAC needs.
  • Experienced Technicians: Our team is highly trained and experienced in all aspects of HVAC service.
  • Upfront Pricing: We provide transparent pricing with no hidden costs.
  • Customer Satisfaction Guaranteed: Your comfort and satisfaction are our top priorities.

Contact Air Bros Today!

Whether you need emergency AC repair, a new heating system installation, or any other HVAC service, Air Bros is here to help. Contact us today for a free consultation or to schedule a service appointment. We're proud to be your trusted HVAC partner in St. Petersburg!

Call us at 727-217-6148 or contact us online today!

Recent Jobs and Reviews in St. Petersburg, FL

St. Petersburg, FL at a glance

Air Bros Air Conditioning & Electrical has completed 25 jobs in St. Petersburg, FL in May 2026.

The most recent job was on May 19, 2026.

Air Bros Air Conditioning & Electrical has completed 1,919 jobs in St. Petersburg, FL in the last 12 months. The first job there was in December 2024.

Job Locations and Reviews

System has a restriction. Heater kit intermittently running. Submititng estimates. Electric bill high in home.
System has a restriction. Heater kit intermittently running. Submititng estimates. Electric bill high in home.
Nathan A.
Nathan A. Checked in
System has a restriction. Heater kit intermittently running. Submititng estimates. Electric bill high in home.
St. Petersburg, FL 33704
Recover refrigerant, install new warranty condenser coil, recharge system. Start and test. Unit cooling properly at this time.
Recover refrigerant, install new warranty condenser coil, recharge system. Start and test. Unit cooling properly at this time.
Justin G.
Justin G. Checked in
Recover refrigerant, install new warranty condenser coil, recharge system. Start and test. Unit cooling properly at this time.
St. Petersburg, FL 33714
Reason for call:
No cool

Equipment:
2021 Goodman 4 ton 
Vertical in closet 
Condenser on right side of home 

Summary:
On arrival found system low on refrigerant. Found condenser coil dirty found UV kit failed. Found a leak in the evaporator coil.
System is under parts warranty the evaporator coil will need to be replaced. 

Solution:
Added 2 pounds of refrigerant to complete leak search and to have temporary cooling. Homeowner signed up on membership today. 
Sold the cleaning of condenser coil, new UV kit, evaporator coil change out for later date scheduled for Thursday 5/21.
Reason for call:
No cool

Equipment:
2021 Goodman 4 ton 
Vertical in closet 
Condenser on right side of home 

Summary:
On arrival found system low on refrigerant. Found condenser coil dirty found UV kit failed. Found a leak in the evaporator coil.
System is under parts warranty the evaporator coil will need to be replaced. 

Solution:
Added 2 pounds of refrigerant to complete leak search and to have temporary cooling. Homeowner signed up on membership today. 
Sold the cleaning of condenser coil, new UV kit, evaporator coil change out for later date scheduled for Thursday 5/21.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Equipment: 2021 Goodman 4 ton Vertical in closet Condenser on right side of home Summary: On arrival found system low on refrigerant. Found condenser coil dirty found UV kit failed. Found a leak in the evaporator coil. System is under parts warranty the evaporator coil will need to be replaced. Solution: Added 2 pounds of refrigerant to complete leak search and to have temporary cooling. Homeowner signed up on membership today. Sold the cleaning of condenser coil, new UV kit, evaporator coil change out for later date scheduled for Thursday 5/21.
St. Petersburg, FL 33703
Upon arrival, I found that the float switch at the air handler had been triggered due to a clogged condensate drain line. I discussed the issue with the homeowner and explained that the drain line required a full treatment using nitrogen, drain cleaner, and a water flush to properly clear the blockage.

I began by connecting my shop vacuum to remove standing debris and buildup from the drain line. I then used nitrogen pressure to clear any remaining blockage inside the line. Afterward, I performed a drain line treatment and thoroughly flushed the PVC drain to ensure proper drainage. I also treated and inspected the condensate drain pan inside the air handler to verify there were no additional restrictions or buildup present.

Once the cleaning was completed, I confirmed strong suction and proper drainage through the condensate line. I also checked system performance and recorded a 19° temperature split between the supply and return air, indicating the system is operating properly at th
Upon arrival, I found that the float switch at the air handler had been triggered due to a clogged condensate drain line. I discussed the issue with the homeowner and explained that the drain line required a full treatment using nitrogen, drain cleaner, and a water flush to properly clear the blockage.

I began by connecting my shop vacuum to remove standing debris and buildup from the drain line. I then used nitrogen pressure to clear any remaining blockage inside the line. Afterward, I performed a drain line treatment and thoroughly flushed the PVC drain to ensure proper drainage. I also treated and inspected the condensate drain pan inside the air handler to verify there were no additional restrictions or buildup present.

Once the cleaning was completed, I confirmed strong suction and proper drainage through the condensate line. I also checked system performance and recorded a 19° temperature split between the supply and return air, indicating the system is operating properly at th
Ace m.
Ace m. Checked in
Upon arrival, I found that the float switch at the air handler had been triggered due to a clogged condensate drain line. I discussed the issue with the homeowner and explained that the drain line required a full treatment using nitrogen, drain cleaner, and a water flush to properly clear the blockage. I began by connecting my shop vacuum to remove standing debris and buildup from the drain line. I then used nitrogen pressure to clear any remaining blockage inside the line. Afterward, I performed a drain line treatment and thoroughly flushed the PVC drain to ensure proper drainage. I also treated and inspected the condensate drain pan inside the air handler to verify there were no additional restrictions or buildup present. Once the cleaning was completed, I confirmed strong suction and proper drainage through the condensate line. I also checked system performance and recorded a 19° temperature split between the supply and return air, indicating the system is operating properly at th
St. Petersburg, FL 33703
Reason for call:
Tune up 

Equipment:
2023 ruud 4 ton 
Vertical in closet 
Condenser on left side of home

Summary:
Competed tune up to find equipment operating properly. Flushed indoor and outdoor coils. Flushed drain and drain line. First liters have been maintained properly. Lights flicker on start up 

Solution:
Recommended soft start for equipment. Recommended membership for maintenance.
Reason for call:
Tune up 

Equipment:
2023 ruud 4 ton 
Vertical in closet 
Condenser on left side of home

Summary:
Competed tune up to find equipment operating properly. Flushed indoor and outdoor coils. Flushed drain and drain line. First liters have been maintained properly. Lights flicker on start up 

Solution:
Recommended soft start for equipment. Recommended membership for maintenance.
Corbin C.
Corbin C. Checked in
Reason for call: Tune up Equipment: 2023 ruud 4 ton Vertical in closet Condenser on left side of home Summary: Competed tune up to find equipment operating properly. Flushed indoor and outdoor coils. Flushed drain and drain line. First liters have been maintained properly. Lights flicker on start up Solution: Recommended soft start for equipment. Recommended membership for maintenance.
St. Petersburg, FL 33702
On arrival found unit cooling. Client states that unit struggles to cool home in heat of day. Found multiple issues with unit. Inspected ductwork and found leaking air in attic and insulation on grills. Made client aware that ductwork should be replaced however ceiling would need to be removed. Will submit estimates for repairs and additional cooling with mini splits. Unit is cooling to the best of its ability.
On arrival found unit cooling. Client states that unit struggles to cool home in heat of day. Found multiple issues with unit. Inspected ductwork and found leaking air in attic and insulation on grills. Made client aware that ductwork should be replaced however ceiling would need to be removed. Will submit estimates for repairs and additional cooling with mini splits. Unit is cooling to the best of its ability.
Justin G.
Justin G. Checked in
On arrival found unit cooling. Client states that unit struggles to cool home in heat of day. Found multiple issues with unit. Inspected ductwork and found leaking air in attic and insulation on grills. Made client aware that ductwork should be replaced however ceiling would need to be removed. Will submit estimates for repairs and additional cooling with mini splits. Unit is cooling to the best of its ability.
St. Petersburg, FL 33702
Install ac disconnect at air handler 
Install GFCI receptacle in kitchen for code compliance 
Install new receptacle for microwave to remove miss wired and back stabbed receptacle 
The kitchen outlet had a ground connection not a hot and neutral reversed rewired receptacle properly 
Install cover plate on receptacle in bathroom that was missing 
Removed double tapped connection in panel for the surge protector that was no longer functioning installed a Knock out seal in panel
Install ac disconnect at air handler 
Install GFCI receptacle in kitchen for code compliance 
Install new receptacle for microwave to remove miss wired and back stabbed receptacle 
The kitchen outlet had a ground connection not a hot and neutral reversed rewired receptacle properly 
Install cover plate on receptacle in bathroom that was missing 
Removed double tapped connection in panel for the surge protector that was no longer functioning installed a Knock out seal in panel
Griffin K.
Griffin K. Checked in
Install ac disconnect at air handler Install GFCI receptacle in kitchen for code compliance Install new receptacle for microwave to remove miss wired and back stabbed receptacle The kitchen outlet had a ground connection not a hot and neutral reversed rewired receptacle properly Install cover plate on receptacle in bathroom that was missing Removed double tapped connection in panel for the surge protector that was no longer functioning installed a Knock out seal in panel
St. Petersburg, FL 33710
Upon arrival home owner states outdoor unit is not running. Home owner replaced capacitor (verified wiring and strapped up for home owner).

Air handler secondary pan full of water and extra catch pan. This causing system to intermittently run. Explained attic is very humid and unit is condensing on bottom. Found drain line had no trap and air handler primary pan holding water. 

Cleared drain pans and catch pan. Cleared drain line and added pan tabs. Added trap and primed on exterior. Verified system operations. 

Unit is currently operating within manufacture specification. Verified indoor and outdoor coil conditions. Verified blower motor running and filter condition. 

If issue happens again explained to home owner we would need to do a roof cut in attic fan to bring down humidity/attic temp. No gable vents on home. 

Went over options and membership program.
Upon arrival home owner states outdoor unit is not running. Home owner replaced capacitor (verified wiring and strapped up for home owner).

Air handler secondary pan full of water and extra catch pan. This causing system to intermittently run. Explained attic is very humid and unit is condensing on bottom. Found drain line had no trap and air handler primary pan holding water. 

Cleared drain pans and catch pan. Cleared drain line and added pan tabs. Added trap and primed on exterior. Verified system operations. 

Unit is currently operating within manufacture specification. Verified indoor and outdoor coil conditions. Verified blower motor running and filter condition. 

If issue happens again explained to home owner we would need to do a roof cut in attic fan to bring down humidity/attic temp. No gable vents on home. 

Went over options and membership program.
Nathan A.
Nathan A. Checked in
Upon arrival home owner states outdoor unit is not running. Home owner replaced capacitor (verified wiring and strapped up for home owner). Air handler secondary pan full of water and extra catch pan. This causing system to intermittently run. Explained attic is very humid and unit is condensing on bottom. Found drain line had no trap and air handler primary pan holding water. Cleared drain pans and catch pan. Cleared drain line and added pan tabs. Added trap and primed on exterior. Verified system operations. Unit is currently operating within manufacture specification. Verified indoor and outdoor coil conditions. Verified blower motor running and filter condition. If issue happens again explained to home owner we would need to do a roof cut in attic fan to bring down humidity/attic temp. No gable vents on home. Went over options and membership program.
St. Petersburg, FL 33703
Upon arrival, I started by checking the temperature difference between the supply and return air. The system had an 18° temperature split, which is within a healthy operating range.

I then checked the refrigerant cycle and found no signs of leaks or restrictions at this time. Moving on to the electrical components, both motors and the compressor were operating within proper amperage range with no signs of overamping, shorts, or burnt electrical components.

Overall, the system is mechanically functioning properly with no signs of immediate failure. During today’s maintenance, I performed a drain line treatment, condenser coil cleaning, and an air handler inspection. Overall, the tune-up went well and there are currently no mechanical recommendations for the system.

The homeowner mentioned interest in upgrading to a Wi-Fi thermostat when replacing the current thermostat. During inspection, I found that the existing thermostat wiring was never upgraded when the previous homeowners repl
Upon arrival, I started by checking the temperature difference between the supply and return air. The system had an 18° temperature split, which is within a healthy operating range.

I then checked the refrigerant cycle and found no signs of leaks or restrictions at this time. Moving on to the electrical components, both motors and the compressor were operating within proper amperage range with no signs of overamping, shorts, or burnt electrical components.

Overall, the system is mechanically functioning properly with no signs of immediate failure. During today’s maintenance, I performed a drain line treatment, condenser coil cleaning, and an air handler inspection. Overall, the tune-up went well and there are currently no mechanical recommendations for the system.

The homeowner mentioned interest in upgrading to a Wi-Fi thermostat when replacing the current thermostat. During inspection, I found that the existing thermostat wiring was never upgraded when the previous homeowners repl
Ace m.
Ace m. Checked in
Upon arrival, I started by checking the temperature difference between the supply and return air. The system had an 18° temperature split, which is within a healthy operating range. I then checked the refrigerant cycle and found no signs of leaks or restrictions at this time. Moving on to the electrical components, both motors and the compressor were operating within proper amperage range with no signs of overamping, shorts, or burnt electrical components. Overall, the system is mechanically functioning properly with no signs of immediate failure. During today’s maintenance, I performed a drain line treatment, condenser coil cleaning, and an air handler inspection. Overall, the tune-up went well and there are currently no mechanical recommendations for the system. The homeowner mentioned interest in upgrading to a Wi-Fi thermostat when replacing the current thermostat. During inspection, I found that the existing thermostat wiring was never upgraded when the previous homeowners repl
St. Petersburg, FL 33703
On arrival found unit not cooling h due to weak capacitor. Client opted to replace both contactor and capacitor. Start and test. Pressures good. Temp split good. Coil and blower clean. Complimentary cleared drain and added chemical to pan. Unit is cooling properly at this time.
On arrival found unit not cooling h due to weak capacitor. Client opted to replace both contactor and capacitor. Start and test. Pressures good. Temp split good. Coil and blower clean. Complimentary cleared drain and added chemical to pan. Unit is cooling properly at this time.
Justin G.
Justin G. Checked in
On arrival found unit not cooling h due to weak capacitor. Client opted to replace both contactor and capacitor. Start and test. Pressures good. Temp split good. Coil and blower clean. Complimentary cleared drain and added chemical to pan. Unit is cooling properly at this time.
St. Petersburg, FL 33701
Upon arrival, the system was operating. I checked the temperature differential and recorded a 19° split, which is within range. During further inspection, I noticed the condenser was radiating an excessive amount of heat, and the condenser coil was heavily restricted, limiting proper airflow.

I checked system pressures and found the high-side pressure to be approximately 500 PSI, which is extremely high. The compressor was over-amping due to the excessive operating conditions. At this time, the system is experiencing failing components and is operating under severe stress.

There is currently no access to the air handler. Since the original installation, maintenance has not been able to be properly performed because access was completely removed when the ceiling was closed off during installation. Due to the lack of accessibility and the condition of the system, replacement is the recommended solution.

We discussed possible replacement options, including relocating the system to a mo
Upon arrival, the system was operating. I checked the temperature differential and recorded a 19° split, which is within range. During further inspection, I noticed the condenser was radiating an excessive amount of heat, and the condenser coil was heavily restricted, limiting proper airflow.

I checked system pressures and found the high-side pressure to be approximately 500 PSI, which is extremely high. The compressor was over-amping due to the excessive operating conditions. At this time, the system is experiencing failing components and is operating under severe stress.

There is currently no access to the air handler. Since the original installation, maintenance has not been able to be properly performed because access was completely removed when the ceiling was closed off during installation. Due to the lack of accessibility and the condition of the system, replacement is the recommended solution.

We discussed possible replacement options, including relocating the system to a mo
Ace m.
Ace m. Checked in
Upon arrival, the system was operating. I checked the temperature differential and recorded a 19° split, which is within range. During further inspection, I noticed the condenser was radiating an excessive amount of heat, and the condenser coil was heavily restricted, limiting proper airflow. I checked system pressures and found the high-side pressure to be approximately 500 PSI, which is extremely high. The compressor was over-amping due to the excessive operating conditions. At this time, the system is experiencing failing components and is operating under severe stress. There is currently no access to the air handler. Since the original installation, maintenance has not been able to be properly performed because access was completely removed when the ceiling was closed off during installation. Due to the lack of accessibility and the condition of the system, replacement is the recommended solution. We discussed possible replacement options, including relocating the system to a mo
St. Petersburg, FL 33713
Reason for call:
No cool 

Equipment:
2021 Icp 4 ton 
Horizontal in attic 
Condenser on right side 

Summary: 
Completed diagnostic to find a leak within evaporator coil and txv metering device both will have to be replaced under parts warranty

Solution for today:
2 pounds of 410 
Leak search to find refrigerant leak 
Seal up supply plenum properly 

Solution for future:
Estimate will be sent in the morning for proper repairs
Homeowner is willing to expedite parts and/or repair
Reason for call:
No cool 

Equipment:
2021 Icp 4 ton 
Horizontal in attic 
Condenser on right side 

Summary: 
Completed diagnostic to find a leak within evaporator coil and txv metering device both will have to be replaced under parts warranty

Solution for today:
2 pounds of 410 
Leak search to find refrigerant leak 
Seal up supply plenum properly 

Solution for future:
Estimate will be sent in the morning for proper repairs
Homeowner is willing to expedite parts and/or repair
Corbin C.
Corbin C. Checked in
Reason for call: No cool Equipment: 2021 Icp 4 ton Horizontal in attic Condenser on right side Summary: Completed diagnostic to find a leak within evaporator coil and txv metering device both will have to be replaced under parts warranty Solution for today: 2 pounds of 410 Leak search to find refrigerant leak Seal up supply plenum properly Solution for future: Estimate will be sent in the morning for proper repairs Homeowner is willing to expedite parts and/or repair
St. Petersburg, FL 33707
Clogged drain 

Homeowner had 79$ tuneup coupon 

Signed up for maintenance plan 

Performed maintenance 

Cleared drain line and pan 

Added pan tabs to help with buildup 

Cleaned outdoor coils 

Verified system operations 

*leaky ducting
Clogged drain 

Homeowner had 79$ tuneup coupon 

Signed up for maintenance plan 

Performed maintenance 

Cleared drain line and pan 

Added pan tabs to help with buildup 

Cleaned outdoor coils 

Verified system operations 

*leaky ducting
Nathan A.
Nathan A. Checked in
Clogged drain Homeowner had 79$ tuneup coupon Signed up for maintenance plan Performed maintenance Cleared drain line and pan Added pan tabs to help with buildup Cleaned outdoor coils Verified system operations *leaky ducting
St. Petersburg, FL 33713
Inspected unit for improper cooling. Found pressures to be in range. Unit has 20* split. Attic fan is operational. Float is clear. Home struggles to cool due to possible lack of insulation in walls. Home has always struggled to keep cool during summer months. Recommend supplemental cooling in living room and kitchen. Will submit estimate for mini split.
Inspected unit for improper cooling. Found pressures to be in range. Unit has 20* split. Attic fan is operational. Float is clear. Home struggles to cool due to possible lack of insulation in walls. Home has always struggled to keep cool during summer months. Recommend supplemental cooling in living room and kitchen. Will submit estimate for mini split.
Justin G.
Justin G. Checked in
Inspected unit for improper cooling. Found pressures to be in range. Unit has 20* split. Attic fan is operational. Float is clear. Home struggles to cool due to possible lack of insulation in walls. Home has always struggled to keep cool during summer months. Recommend supplemental cooling in living room and kitchen. Will submit estimate for mini split.
St. Petersburg, FL 33703
Upon arrival, I found the air handler drain pan completely full of water. I inspected the safety float switches and confirmed that both sensors were activated due to the high water level in the pan. To properly test the system and verify equipment operation, I temporarily disconnected the safety sensors.

After completing a full diagnostic of the system, all mechanical and electrical components were found to be operating properly. No issues were found with the equipment itself, and the problem was determined to be related to the condensate drain line.

I informed the homeowner of my findings and proceeded with a drain line treatment. Before leaving, I verified that the drain line was flowing and draining properly, rechecked system operation, and confirmed everything was functioning as designed.

If you have any questions, please feel free to reach out. Thank you for your business, and have a great day.
Upon arrival, I found the air handler drain pan completely full of water. I inspected the safety float switches and confirmed that both sensors were activated due to the high water level in the pan. To properly test the system and verify equipment operation, I temporarily disconnected the safety sensors.

After completing a full diagnostic of the system, all mechanical and electrical components were found to be operating properly. No issues were found with the equipment itself, and the problem was determined to be related to the condensate drain line.

I informed the homeowner of my findings and proceeded with a drain line treatment. Before leaving, I verified that the drain line was flowing and draining properly, rechecked system operation, and confirmed everything was functioning as designed.

If you have any questions, please feel free to reach out. Thank you for your business, and have a great day.
Ace m.
Ace m. Checked in
Upon arrival, I found the air handler drain pan completely full of water. I inspected the safety float switches and confirmed that both sensors were activated due to the high water level in the pan. To properly test the system and verify equipment operation, I temporarily disconnected the safety sensors. After completing a full diagnostic of the system, all mechanical and electrical components were found to be operating properly. No issues were found with the equipment itself, and the problem was determined to be related to the condensate drain line. I informed the homeowner of my findings and proceeded with a drain line treatment. Before leaving, I verified that the drain line was flowing and draining properly, rechecked system operation, and confirmed everything was functioning as designed. If you have any questions, please feel free to reach out. Thank you for your business, and have a great day.
St. Petersburg, FL 33704
St. Petersburg, FL - On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Added chemical to help prevent growth. Vacuumed water out of secondary pan and pump. Unit cooling at this time. Attic is extremely hot. Recommend attic fan or roof vents and ventilation in soffit to help circulate air properly and reduce temp in attic.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Added chemical to help prevent growth. Vacuumed water out of secondary pan and pump. Unit cooling at this time. Attic is extremely hot. Recommend attic fan or roof vents and ventilation in soffit to help circulate air properly and reduce temp in attic.
St. Petersburg, FL 33705
Upon arrival, I cut off power and took out the blower wheel, I did a deep cleaning for the blower wheel to ensure airflow is clean in the speed of the fan is proper. Once finished cleaning it, I reinstalled it into the air handler before leaving I made sure I had a healthy temperature difference being at 19°. Everything is functioning properly when I left. If you have any questions, please reach out thank you for your business have a great day.
Upon arrival, I cut off power and took out the blower wheel, I did a deep cleaning for the blower wheel to ensure airflow is clean in the speed of the fan is proper. Once finished cleaning it, I reinstalled it into the air handler before leaving I made sure I had a healthy temperature difference being at 19°. Everything is functioning properly when I left. If you have any questions, please reach out thank you for your business have a great day.
Ace m.
Ace m. Checked in
Upon arrival, I cut off power and took out the blower wheel, I did a deep cleaning for the blower wheel to ensure airflow is clean in the speed of the fan is proper. Once finished cleaning it, I reinstalled it into the air handler before leaving I made sure I had a healthy temperature difference being at 19°. Everything is functioning properly when I left. If you have any questions, please reach out thank you for your business have a great day.
St. Petersburg, FL 33704
79° indoor ambient 62° supply temp 

Cleaned out condensate pump. If issue happens again recommend replacing pump. Cleared drain pan. Cleared screen in pump. Verified operations.
79° indoor ambient 62° supply temp 

Cleaned out condensate pump. If issue happens again recommend replacing pump. Cleared drain pan. Cleared screen in pump. Verified operations.
Nathan A.
Nathan A. Checked in
79° indoor ambient 62° supply temp Cleaned out condensate pump. If issue happens again recommend replacing pump. Cleared drain pan. Cleared screen in pump. Verified operations.
St. Petersburg, FL 33701
Upon arrival, I took a temperature difference between the supply and the return of the mini split and I had a 25° difference being in a healthy range. Moving onto cleaning the condenser coils, and cleaning the inside coils. The blower wheel was impacted with bacterial growth and dust, which I recommend recommended to the homeowner to do a poll and clean, which she agreed upon, but wanted to discuss with her husband and will reach out sometime this week to schedule the appointment. If you have any questions, please reach out. Thank you for your business. Have a great day.
Upon arrival, I took a temperature difference between the supply and the return of the mini split and I had a 25° difference being in a healthy range. Moving onto cleaning the condenser coils, and cleaning the inside coils. The blower wheel was impacted with bacterial growth and dust, which I recommend recommended to the homeowner to do a poll and clean, which she agreed upon, but wanted to discuss with her husband and will reach out sometime this week to schedule the appointment. If you have any questions, please reach out. Thank you for your business. Have a great day.
Ace m.
Ace m. Checked in
Upon arrival, I took a temperature difference between the supply and the return of the mini split and I had a 25° difference being in a healthy range. Moving onto cleaning the condenser coils, and cleaning the inside coils. The blower wheel was impacted with bacterial growth and dust, which I recommend recommended to the homeowner to do a poll and clean, which she agreed upon, but wanted to discuss with her husband and will reach out sometime this week to schedule the appointment. If you have any questions, please reach out. Thank you for your business. Have a great day.
St. Petersburg, FL 33701
On arrival found unit not keeping up due to low refrigerant. Client opted to fill unit without leak search. Once unit filled back to factory specs. Unit cooling properly with 20* split. Noticed ductwork in attic in poor condition and is affected how well unit is able to cool. Home has poor insulation and bare spots in attic. No warranty on refrigerant. If problem happens again a leak search must be performed to locate leak.
On arrival found unit not keeping up due to low refrigerant. Client opted to fill unit without leak search. Once unit filled back to factory specs. Unit cooling properly with 20* split. Noticed ductwork in attic in poor condition and is affected how well unit is able to cool. Home has poor insulation and bare spots in attic. No warranty on refrigerant. If problem happens again a leak search must be performed to locate leak.
Justin G.
Justin G. Checked in
On arrival found unit not keeping up due to low refrigerant. Client opted to fill unit without leak search. Once unit filled back to factory specs. Unit cooling properly with 20* split. Noticed ductwork in attic in poor condition and is affected how well unit is able to cool. Home has poor insulation and bare spots in attic. No warranty on refrigerant. If problem happens again a leak search must be performed to locate leak.
St. Petersburg, FL 33710
Remove and sanitized blower wheel 

Sanitized cabinet and wiring 

Installed whole home air scrubber (reme halo)

Wired in transformer 

Changed filters 

Verified system operations
Remove and sanitized blower wheel 

Sanitized cabinet and wiring 

Installed whole home air scrubber (reme halo)

Wired in transformer 

Changed filters 

Verified system operations
Nathan A.
Nathan A. Checked in
Remove and sanitized blower wheel Sanitized cabinet and wiring Installed whole home air scrubber (reme halo) Wired in transformer Changed filters Verified system operations
St. Petersburg, FL 33701
Upon arrival, I began by checking the temperature split between the supply and return air. The system is operating within proper range with an 18° temperature difference. 

Moving on to the electrical inspection, all motors and the compressor are operating within manufacturer specifications and pulling the correct amperage with no signs of overamping. I did not observe any shorts, burnouts, or electrical concerns at this time. 

The refrigerant cycle is healthy with no indications of leaks or restrictions. I also performed a condenser coil cleaning, drain line treatment, and a full air handler inspection. 

Overall, the homeowner already has the majority of recommended preventative maintenance items installed. I would recommend adding an air purifier to further improve indoor air quality. 

If you have any questions, please feel free to reach out. Thank you for your business, and have a great day.
Upon arrival, I began by checking the temperature split between the supply and return air. The system is operating within proper range with an 18° temperature difference. 

Moving on to the electrical inspection, all motors and the compressor are operating within manufacturer specifications and pulling the correct amperage with no signs of overamping. I did not observe any shorts, burnouts, or electrical concerns at this time. 

The refrigerant cycle is healthy with no indications of leaks or restrictions. I also performed a condenser coil cleaning, drain line treatment, and a full air handler inspection. 

Overall, the homeowner already has the majority of recommended preventative maintenance items installed. I would recommend adding an air purifier to further improve indoor air quality. 

If you have any questions, please feel free to reach out. Thank you for your business, and have a great day.
Ace m.
Ace m. Checked in
Upon arrival, I began by checking the temperature split between the supply and return air. The system is operating within proper range with an 18° temperature difference. Moving on to the electrical inspection, all motors and the compressor are operating within manufacturer specifications and pulling the correct amperage with no signs of overamping. I did not observe any shorts, burnouts, or electrical concerns at this time. The refrigerant cycle is healthy with no indications of leaks or restrictions. I also performed a condenser coil cleaning, drain line treatment, and a full air handler inspection. Overall, the homeowner already has the majority of recommended preventative maintenance items installed. I would recommend adding an air purifier to further improve indoor air quality. If you have any questions, please feel free to reach out. Thank you for your business, and have a great day.
St. Petersburg, FL 33703
On arrival found u it not cooling due to clogged drain. Cleared pan and drain. Added chemical to help prevent growth. Pressures good. Temp split good. Filter dirty and needs to be changed. Unit cooling at this time.
On arrival found u it not cooling due to clogged drain. Cleared pan and drain. Added chemical to help prevent growth. Pressures good. Temp split good. Filter dirty and needs to be changed. Unit cooling at this time.
Justin G.
Justin G. Checked in
On arrival found u it not cooling due to clogged drain. Cleared pan and drain. Added chemical to help prevent growth. Pressures good. Temp split good. Filter dirty and needs to be changed. Unit cooling at this time.
St. Petersburg, FL 33703
Reason for call:
No cool

Equipment:
2020 goodman 2.5 ton 
Horizontal in garage 
Condenser on roof

Summary:
On arrival found dead blower motor call low and high voltage was present at plug. Continued diagnosis to find equipment in good operating order. 

Solution:
Replace blower motor and signed homeowner up in 2 system maintenance plan.
Reason for call:
No cool

Equipment:
2020 goodman 2.5 ton 
Horizontal in garage 
Condenser on roof

Summary:
On arrival found dead blower motor call low and high voltage was present at plug. Continued diagnosis to find equipment in good operating order. 

Solution:
Replace blower motor and signed homeowner up in 2 system maintenance plan.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Equipment: 2020 goodman 2.5 ton Horizontal in garage Condenser on roof Summary: On arrival found dead blower motor call low and high voltage was present at plug. Continued diagnosis to find equipment in good operating order. Solution: Replace blower motor and signed homeowner up in 2 system maintenance plan.
St. Petersburg, FL 33712
Redo flare fitting charge with refrigerant 
Pull vacuum on system 
Restore cooling to unit
Redo flare fitting charge with refrigerant 
Pull vacuum on system 
Restore cooling to unit
Corbin C.
Corbin C. Checked in
Redo flare fitting charge with refrigerant Pull vacuum on system Restore cooling to unit
St. Petersburg, FL 33714
How do I know if my AC needs repair or full replacement?

Our technicians inspect the full system — age, refrigerant type, corrosion, and repair history — and give you an honest recommendation. If a repair makes sense, we'll fix it. If the unit is beyond its useful life, we'll walk you through replacement options with no pressure.

Are your technicians background-checked and licensed?

Yes. Every Air Bros technician is background-checked, factory-trained, and works under our state HVAC license (#CAC1820499) and electrical license (#EC13015085).

What parts of St. Petersburg do you serve?

We serve all of St. Petersburg, including Downtown, Historic Kenwood, Old Northeast, Snell Isle, Crescent Lake, Shore Acres, and Coquina Key, plus Seminole, Largo, Pinellas Park, and the surrounding beach communities.

Do you offer same-day AC repair in St. Petersburg?

Yes. We offer 24/7 emergency AC repair with same-day service throughout St. Petersburg and the surrounding Pinellas County area.

Is Air Bros a local St. Petersburg company, or a franchise?

Air Bros is 100% locally owned and operated, headquartered in the Shore Acres neighborhood of St. Petersburg. We're not a franchise — every technician is a direct employee, not a subcontractor.

Contact the Bros You Know Today!