Instant Quote Shop Filters Call Air Bros

St. Petersburg, FL

air-bros-team-with-truck

The Best AC Repair in St. Petersburg, FL — From Technicians Your Neighbors Already Trust

When your AC quits in the middle of a St. Pete summer, you don't want a stranger in an unmarked van. You want a technician your neighbors already know and trust. Air Bros Air Conditioning & Electrical has been fixing air conditioners in St. Petersburg since 2020, but our roots run deeper — founder Ricky Orta grew up learning the trade from his father and has been a licensed HVAC contractor since 2006. That local, hands-on experience is why homeowners from Historic Kenwood to Snell Isle call us the best AC repair company in St. Petersburg.

We're headquartered right here in the Shore Acres neighborhood, so when you call, you're not routed to a call center — you're talking to the same local team that services your street.

Call us at 727-217-6148 or contact us online today for all of your HVAC, indoor air quality and electrical needs.

Meet the technicians who service St. Petersburg

What to expect when we show up

Calling a repair company you've never used before shouldn't feel like a gamble. Here's exactly how an Air Bros service call goes, every time.

You'll get a heads-up before we arrive, then a uniformed technician in a marked Air Bros vehicle shows up in the window we promised. We diagnose the whole system — not just the obvious symptom — then explain what we found and what your options are before any work starts. You approve the price up front, we make the repair, and we don't leave until we've confirmed the system is cooling the way it should.

Every technician is a background-checked, drug-tested Air Bros employee — never a subcontractor — and each one is trained to service every major AC and heat pump brand. It's the kind of consistency you can only get from a local team that answers to its own name.

And if something isn't right? Our 100% satisfaction guarantee means we make it right.

Signs you need AC repair

St. Petersburg's heat and humidity push air conditioners harder than almost anywhere else in the country. Call for AC repair if you notice:

  • Warm air blowing from vents, or the system running constantly without cooling
  • Water pooling around your air handler (a common issue in St. Pete's older homes with attic-run drain lines)
  • Musty odors or visible mold near vents — a sign of a clogged condensate line or dirty coil
  • Rising humidity indoors despite the AC running
  • Short cycling, tripped breakers, or a system that won't turn on at all

Our technicians diagnose the full system on every call — refrigerant charge, temperature split, electrical connections, and drain line — so you get a real fix, not a temporary patch.

Comprehensive HVAC Services in St. Petersburg

We offer a full range of heating and cooling services to keep your St. Petersburg, FL, home comfortable year-round:

  • Air Conditioning: From AC repair and AC installation to routine maintenance, we ensure your cooling system keeps you comfortable during those hot Florida summers. We offer same-day service for AC emergencies, so you never have to suffer in the heat.
  • Heating: Stay warm and cozy in the winter with our comprehensive heating services. We repair and install all types of heating systems, including furnaces and heat pumps, and offer preventative maintenance to keep your system running efficiently.
  • Indoor Air Quality: Improve your indoor air quality with our dehumidifier and UV light installation services. We'll help you control excess humidity and eliminate airborne contaminants, creating a healthier home environment.
  • Ductwork: Ensure optimal airflow and energy efficiency with our ductwork repair and installation services. We can address leaks and damage, and design a system that's perfect for your home.
  • Pool Heater Services: Extend your swim season with our pool heater installation and repair services.
  • Electrical Services: From outlet and switch replacements to ceiling fan installations to whole-house surge protector installations, we have the experts to handle your electrical service needs.

Our experienced technicians are skilled in all aspects of HVAC service and are dedicated to providing top-quality workmanship and customer care.

Why Choose Air Bros?

  • Local Expertise: We understand the unique climate challenges of St. Petersburg.
  • Fast and Reliable Service: We offer same-day service for AC emergencies and prioritize prompt service for all your HVAC needs.
  • Experienced Technicians: Our team is highly trained and experienced in all aspects of HVAC service.
  • Upfront Pricing: We provide transparent pricing with no hidden costs.
  • Customer Satisfaction Guaranteed: Your comfort and satisfaction are our top priorities.

Contact Air Bros Today!

Whether you need emergency AC repair, a new heating system installation, or any other HVAC service, Air Bros is here to help. Contact us today for a free consultation or to schedule a service appointment. We're proud to be your trusted HVAC partner in St. Petersburg!

Call us at 727-217-6148 or contact us online today!

Recent Jobs and Reviews in St. Petersburg, FL

St. Petersburg, FL at a glance

Air Bros Air Conditioning & Electrical has completed 25 jobs in St. Petersburg, FL in September 2026.

The most recent job was on September 9, 2026.

Air Bros Air Conditioning & Electrical has completed 1,919 jobs in St. Petersburg, FL in the last 12 months. The first job there was in December 2024.

Job Locations and Reviews

Justin G.
Justin G. Checked in
Install ecobee premier with air quality check and room sensor. Tax and labor included.
St. Petersburg, FL 33712
Griffin K.
Griffin K. Checked in
Run customer supplied cameras lines to locations specified by the customer
St. Petersburg, FL 33703
Reason for call:
Tune up special 2 units 

Summary:
Completed tune up on two units to find unit operating well. 
Flushed evaporator coils. 
Flushed drain line and pans. 
Confirmed temperature. 
Confirmed cap readings. Found 35 was weak this part was resplaved today. 70 was properly charged. 
Equipment is in fair condition. 
Changed filters today. 

Solution:
Replace 35 mfd capacitor
Reason for call:
Tune up special 2 units 

Summary:
Completed tune up on two units to find unit operating well. 
Flushed evaporator coils. 
Flushed drain line and pans. 
Confirmed temperature. 
Confirmed cap readings. Found 35 was weak this part was resplaved today. 70 was properly charged. 
Equipment is in fair condition. 
Changed filters today. 

Solution:
Replace 35 mfd capacitor
Corbin C.
Corbin C. Checked in
Reason for call: Tune up special 2 units Summary: Completed tune up on two units to find unit operating well. Flushed evaporator coils. Flushed drain line and pans. Confirmed temperature. Confirmed cap readings. Found 35 was weak this part was resplaved today. 70 was properly charged. Equipment is in fair condition. Changed filters today. Solution: Replace 35 mfd capacitor
St. Petersburg, FL 33701
On arrival found unit not cooling due to bad contactor. Replaced part. Start and test. Pressures good. Temp split good. Capacitor good. Unit is in poor condition with heavy corrosion. Made client aware that system may not make it through another summer. Unit cooling at this time.
On arrival found unit not cooling due to bad contactor. Replaced part. Start and test. Pressures good. Temp split good. Capacitor good. Unit is in poor condition with heavy corrosion. Made client aware that system may not make it through another summer. Unit cooling at this time.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to bad contactor. Replaced part. Start and test. Pressures good. Temp split good. Capacitor good. Unit is in poor condition with heavy corrosion. Made client aware that system may not make it through another summer. Unit cooling at this time.
St. Petersburg, FL 33705
Reason for call:
No cool 

Summary:
System backed up on drain. 
Drain has a kink in it we will be making proper repair to drain tomorrow 11-1
System is running and cooling by 20 degrees 
Charged for diagnostic fee 
Drain repair will be covered under warranty
Reason for call:
No cool 

Summary:
System backed up on drain. 
Drain has a kink in it we will be making proper repair to drain tomorrow 11-1
System is running and cooling by 20 degrees 
Charged for diagnostic fee 
Drain repair will be covered under warranty
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: System backed up on drain. Drain has a kink in it we will be making proper repair to drain tomorrow 11-1 System is running and cooling by 20 degrees Charged for diagnostic fee Drain repair will be covered under warranty
St. Petersburg, FL 33701
Reason for call:
Tune up 

Summary:
Completed tune up on two systems. 
Flushed drain lines and pans. 
Flushed indoor and outdoor coils. 
Replaced filters. 
Confirmed proper temperature. 
Confirmed proper amp draws. 
Confirms capacitor readings. 

Found fan cap on downstairs unit weak
Found dual capacitor on upstairs unit weak 
Found contactor on upstairs unit to be worn down on contact points. 

There are some duct work concerns. 
Attic is too tight to access duct work. 
Homeowner will have to have ceiling removed and have us back out to inspect further. 

Homeowner signed up for maintenance membership
Reason for call:
Tune up 

Summary:
Completed tune up on two systems. 
Flushed drain lines and pans. 
Flushed indoor and outdoor coils. 
Replaced filters. 
Confirmed proper temperature. 
Confirmed proper amp draws. 
Confirms capacitor readings. 

Found fan cap on downstairs unit weak
Found dual capacitor on upstairs unit weak 
Found contactor on upstairs unit to be worn down on contact points. 

There are some duct work concerns. 
Attic is too tight to access duct work. 
Homeowner will have to have ceiling removed and have us back out to inspect further. 

Homeowner signed up for maintenance membership
Corbin C.
Corbin C. Checked in
Reason for call: Tune up Summary: Completed tune up on two systems. Flushed drain lines and pans. Flushed indoor and outdoor coils. Replaced filters. Confirmed proper temperature. Confirmed proper amp draws. Confirms capacitor readings. Found fan cap on downstairs unit weak Found dual capacitor on upstairs unit weak Found contactor on upstairs unit to be worn down on contact points. There are some duct work concerns. Attic is too tight to access duct work. Homeowner will have to have ceiling removed and have us back out to inspect further. Homeowner signed up for maintenance membership
St. Petersburg, FL 33704
Tenant/Owner

Owner states tenant is responsible for repairs 

2015 Trane System (Out of Warranty)

208v Power Grid 

Diagnostic 
-system freezing over and filling secondary drain pan. System freezing over due to low refrigerant. This indicates leak in system 

Further Notes 
-air handler txv bulb to be insulated 
-outdoor Condneser coils impacted with dirt/debris 
-outdoor high voltage disconnect bypassed 

Spoke to owner and would like estimate to replace. Went over repairs and future repairs. Spoke to tenant about repairs and replacement. 

No decision made at this time. System is not operating properly
Tenant/Owner

Owner states tenant is responsible for repairs 

2015 Trane System (Out of Warranty)

208v Power Grid 

Diagnostic 
-system freezing over and filling secondary drain pan. System freezing over due to low refrigerant. This indicates leak in system 

Further Notes 
-air handler txv bulb to be insulated 
-outdoor Condneser coils impacted with dirt/debris 
-outdoor high voltage disconnect bypassed 

Spoke to owner and would like estimate to replace. Went over repairs and future repairs. Spoke to tenant about repairs and replacement. 

No decision made at this time. System is not operating properly
Nathan A.
Nathan A. Checked in
Tenant/Owner Owner states tenant is responsible for repairs 2015 Trane System (Out of Warranty) 208v Power Grid Diagnostic -system freezing over and filling secondary drain pan. System freezing over due to low refrigerant. This indicates leak in system Further Notes -air handler txv bulb to be insulated -outdoor Condneser coils impacted with dirt/debris -outdoor high voltage disconnect bypassed Spoke to owner and would like estimate to replace. Went over repairs and future repairs. Spoke to tenant about repairs and replacement. No decision made at this time. System is not operating properly
St. Petersburg, FL 33713
Reason for call:
Member tune up 

Summary:
Completed service to find clogged drain.
Flushed drain line 
Flushed evaporator coil
Confirmed proper temperature 
Confirmed proper amp draws 
Confirmed proper capacitor reading 

Float switch was engaged and not turning system off on arrival
Reason for call:
Member tune up 

Summary:
Completed service to find clogged drain.
Flushed drain line 
Flushed evaporator coil
Confirmed proper temperature 
Confirmed proper amp draws 
Confirmed proper capacitor reading 

Float switch was engaged and not turning system off on arrival
Corbin C.
Corbin C. Checked in
Reason for call: Member tune up Summary: Completed service to find clogged drain. Flushed drain line Flushed evaporator coil Confirmed proper temperature Confirmed proper amp draws Confirmed proper capacitor reading Float switch was engaged and not turning system off on arrival
St. Petersburg, FL 33701
Upstairs Systems 
-outdoor unit fan motor not operating due to failed capacitor 

Replaced capacitor and verified system operations
Upstairs Systems 
-outdoor unit fan motor not operating due to failed capacitor 

Replaced capacitor and verified system operations
Nathan A.
Nathan A. Checked in
Upstairs Systems -outdoor unit fan motor not operating due to failed capacitor Replaced capacitor and verified system operations
St. Petersburg, FL 33704
5 year warranty 

The capacitor was completely dead, replaced it, and the system is functioning properly with a 20° temperature difference
5 year warranty 

The capacitor was completely dead, replaced it, and the system is functioning properly with a 20° temperature difference
Ace m.
Ace m. Checked in
5 year warranty The capacitor was completely dead, replaced it, and the system is functioning properly with a 20° temperature difference
St. Petersburg, FL 33713
Upon arrival, the homeowner reported a water stain on the ceiling. I inspected the AC system and found the secondary drain pan completely full of water underneath the plenum, with water actively dripping into the surrounding insulation. Upon further inspection, I found that the primary drain line was clogged, causing the water to back up into the secondary pan.

I discussed my findings and recommended enrolling both systems in our maintenance plan. The homeowner agreed and signed up for the maintenance plan for both systems.

I performed a complete drain line cleaning and drain pan cleaning. I also installed a new P-trap on the exterior of the system, as the existing trap had broken off and was no longer functional.

After completing the repairs and maintenance, I tested the system and confirmed that everything is turning on and operating properly. The system is currently producing an 18°F temperature difference, which is within a healthy operating range.

If you have any questions or
Upon arrival, the homeowner reported a water stain on the ceiling. I inspected the AC system and found the secondary drain pan completely full of water underneath the plenum, with water actively dripping into the surrounding insulation. Upon further inspection, I found that the primary drain line was clogged, causing the water to back up into the secondary pan.

I discussed my findings and recommended enrolling both systems in our maintenance plan. The homeowner agreed and signed up for the maintenance plan for both systems.

I performed a complete drain line cleaning and drain pan cleaning. I also installed a new P-trap on the exterior of the system, as the existing trap had broken off and was no longer functional.

After completing the repairs and maintenance, I tested the system and confirmed that everything is turning on and operating properly. The system is currently producing an 18°F temperature difference, which is within a healthy operating range.

If you have any questions or
Ace m.
Ace m. Checked in
Upon arrival, the homeowner reported a water stain on the ceiling. I inspected the AC system and found the secondary drain pan completely full of water underneath the plenum, with water actively dripping into the surrounding insulation. Upon further inspection, I found that the primary drain line was clogged, causing the water to back up into the secondary pan. I discussed my findings and recommended enrolling both systems in our maintenance plan. The homeowner agreed and signed up for the maintenance plan for both systems. I performed a complete drain line cleaning and drain pan cleaning. I also installed a new P-trap on the exterior of the system, as the existing trap had broken off and was no longer functional. After completing the repairs and maintenance, I tested the system and confirmed that everything is turning on and operating properly. The system is currently producing an 18°F temperature difference, which is within a healthy operating range. If you have any questions or
St. Petersburg, FL 33703
Air handler is falling off the wall due to faulty and poorly installed wall brackets. This is causing the system to leak water. 
Air handler evaporator coils were frozen up client stated. 
Air filter was extremely dirty and pressures show system slightly low on refrigerant. Both of these issues can cause coils to freeze up. 

Sending quote for air handler uninstallation, proper mounting, and reinstallation. 

Also offered full system replacement with the new air handler being installed on a floor adjustable stand instead of a wall mount. 
Client would like a quote for full system replacement with improvements. 

Client is running system at this time and I warned that water damage may continue. Client is temporarily bracing unit up with a chair

Client also had concerns of ceiling damage around a couple supply vents in the living room and Florida room. The ceiling is dry at this time and could have been previously damaged. Told client to let the system run for a couple of days and see i
Air handler is falling off the wall due to faulty and poorly installed wall brackets. This is causing the system to leak water. 
Air handler evaporator coils were frozen up client stated. 
Air filter was extremely dirty and pressures show system slightly low on refrigerant. Both of these issues can cause coils to freeze up. 

Sending quote for air handler uninstallation, proper mounting, and reinstallation. 

Also offered full system replacement with the new air handler being installed on a floor adjustable stand instead of a wall mount. 
Client would like a quote for full system replacement with improvements. 

Client is running system at this time and I warned that water damage may continue. Client is temporarily bracing unit up with a chair

Client also had concerns of ceiling damage around a couple supply vents in the living room and Florida room. The ceiling is dry at this time and could have been previously damaged. Told client to let the system run for a couple of days and see i
Michael A.
Michael A. Checked in
Air handler is falling off the wall due to faulty and poorly installed wall brackets. This is causing the system to leak water. Air handler evaporator coils were frozen up client stated. Air filter was extremely dirty and pressures show system slightly low on refrigerant. Both of these issues can cause coils to freeze up. Sending quote for air handler uninstallation, proper mounting, and reinstallation. Also offered full system replacement with the new air handler being installed on a floor adjustable stand instead of a wall mount. Client would like a quote for full system replacement with improvements. Client is running system at this time and I warned that water damage may continue. Client is temporarily bracing unit up with a chair Client also had concerns of ceiling damage around a couple supply vents in the living room and Florida room. The ceiling is dry at this time and could have been previously damaged. Told client to let the system run for a couple of days and see i
St. Petersburg, FL 33704
Found bad capacitor. 
Replaced capacitor and started system. Verified amp draws are good. 
Cleaned out service panel of debris. Made all connections tight. 
System is cooling at this time. 
System will need a few hours to cool down the home as it is 87° inside. 
Contactar is making a slight buzzing noise. Contactar may fail in the future as this is a sign of a slightly poor connection. Client would like to leave it alone at this time. 

Client cleaned drain line yesterday. 

1 year warranty on part installed today.
Found bad capacitor. 
Replaced capacitor and started system. Verified amp draws are good. 
Cleaned out service panel of debris. Made all connections tight. 
System is cooling at this time. 
System will need a few hours to cool down the home as it is 87° inside. 
Contactar is making a slight buzzing noise. Contactar may fail in the future as this is a sign of a slightly poor connection. Client would like to leave it alone at this time. 

Client cleaned drain line yesterday. 

1 year warranty on part installed today.
Michael A.
Michael A. Checked in
Found bad capacitor. Replaced capacitor and started system. Verified amp draws are good. Cleaned out service panel of debris. Made all connections tight. System is cooling at this time. System will need a few hours to cool down the home as it is 87° inside. Contactar is making a slight buzzing noise. Contactar may fail in the future as this is a sign of a slightly poor connection. Client would like to leave it alone at this time. Client cleaned drain line yesterday. 1 year warranty on part installed today.
St. Petersburg, FL 33705
Ricky O.
Ricky O. Checked in
Cleaned drain line and pan
St. Petersburg, FL 33714
Upon my inspection, found system has a severely clogged drain line, dirty condenser coils, and a weak capacitor. Performed a lvl 3 drain cleaning, cleaned condenser coils complimentary, and replaced capacitor. 
System is cooling and draining at this time. 

Noticed system has a higher temperature split however fan speed is on highest setting. Return duct is 14” for a 3 ton system. 
If there is an issue with cooling in the future we can diagnose why, however system is cooling down the home well at this time. 
Checked system pressures and verified they are within range. 

Took a quick look at the mini split and cleaned air filter and vacuumed drain line. Mini split system is cooling well and is very clean.
Upon my inspection, found system has a severely clogged drain line, dirty condenser coils, and a weak capacitor. Performed a lvl 3 drain cleaning, cleaned condenser coils complimentary, and replaced capacitor. 
System is cooling and draining at this time. 

Noticed system has a higher temperature split however fan speed is on highest setting. Return duct is 14” for a 3 ton system. 
If there is an issue with cooling in the future we can diagnose why, however system is cooling down the home well at this time. 
Checked system pressures and verified they are within range. 

Took a quick look at the mini split and cleaned air filter and vacuumed drain line. Mini split system is cooling well and is very clean.
Michael A.
Michael A. Checked in
Upon my inspection, found system has a severely clogged drain line, dirty condenser coils, and a weak capacitor. Performed a lvl 3 drain cleaning, cleaned condenser coils complimentary, and replaced capacitor. System is cooling and draining at this time. Noticed system has a higher temperature split however fan speed is on highest setting. Return duct is 14” for a 3 ton system. If there is an issue with cooling in the future we can diagnose why, however system is cooling down the home well at this time. Checked system pressures and verified they are within range. Took a quick look at the mini split and cleaned air filter and vacuumed drain line. Mini split system is cooling well and is very clean.
St. Petersburg, FL 33704
Found bad capacitor and contactar with a burnt up wire. 
Replaced both components and made new wire connection. 
Got system up and running however the system is struggling with efficiency. 
Found system has a small refrigerant restriction, missing insulation on copper. 
Client would like to move foward with replacing 14 year old system. 
Quote accepted and scheduled for Friday.
Found bad capacitor and contactar with a burnt up wire. 
Replaced both components and made new wire connection. 
Got system up and running however the system is struggling with efficiency. 
Found system has a small refrigerant restriction, missing insulation on copper. 
Client would like to move foward with replacing 14 year old system. 
Quote accepted and scheduled for Friday.
Michael A.
Michael A. Checked in
Found bad capacitor and contactar with a burnt up wire. Replaced both components and made new wire connection. Got system up and running however the system is struggling with efficiency. Found system has a small refrigerant restriction, missing insulation on copper. Client would like to move foward with replacing 14 year old system. Quote accepted and scheduled for Friday.
St. Petersburg, FL 33704
Severely clogged drain. 
Performed lvl 3 treatment. 
If issues persist with drain line we will need to replace drain line. 

System is cooling and draining at this time.

Client needs to order and install 18x18 filter and 16x16 filter asap. There are no filters currently installed. 

We recommend our maitenence plan to properly maintain the equipment and drain line cleanings.
Severely clogged drain. 
Performed lvl 3 treatment. 
If issues persist with drain line we will need to replace drain line. 

System is cooling and draining at this time.

Client needs to order and install 18x18 filter and 16x16 filter asap. There are no filters currently installed. 

We recommend our maitenence plan to properly maintain the equipment and drain line cleanings.
Michael A.
Michael A. Checked in
Severely clogged drain. Performed lvl 3 treatment. If issues persist with drain line we will need to replace drain line. System is cooling and draining at this time. Client needs to order and install 18x18 filter and 16x16 filter asap. There are no filters currently installed. We recommend our maitenence plan to properly maintain the equipment and drain line cleanings.
St. Petersburg, FL 33703
Upon my inspection, found system is leaking water due to a clogged drain line and a failed primary float switch.
Performed a drain cleaning and treatment on system. Inspected evaporator coils and found severely dirty evaporator coils.
Client would like to move forward with  quote to pull and clean evaporator coils as well as installing a new primary float switch.
System is a 16 seer 2 1/2 ton condenser straight cool with a 3 ton air handler. The indoor blower motor was set to speed tap five. I adjusted to speed tap three for a 2 1/2 ton condenser.
System is cooling at this time with a 20° temperature split.
Will perform first maintenance with quoted Work.
Upon my inspection, found system is leaking water due to a clogged drain line and a failed primary float switch.
Performed a drain cleaning and treatment on system. Inspected evaporator coils and found severely dirty evaporator coils.
Client would like to move forward with  quote to pull and clean evaporator coils as well as installing a new primary float switch.
System is a 16 seer 2 1/2 ton condenser straight cool with a 3 ton air handler. The indoor blower motor was set to speed tap five. I adjusted to speed tap three for a 2 1/2 ton condenser.
System is cooling at this time with a 20° temperature split.
Will perform first maintenance with quoted Work.
Michael A.
Michael A. Checked in
Upon my inspection, found system is leaking water due to a clogged drain line and a failed primary float switch. Performed a drain cleaning and treatment on system. Inspected evaporator coils and found severely dirty evaporator coils. Client would like to move forward with quote to pull and clean evaporator coils as well as installing a new primary float switch. System is a 16 seer 2 1/2 ton condenser straight cool with a 3 ton air handler. The indoor blower motor was set to speed tap five. I adjusted to speed tap three for a 2 1/2 ton condenser. System is cooling at this time with a 20° temperature split. Will perform first maintenance with quoted Work.
St. Petersburg, FL 33710
Ricky O.
Ricky O. Checked in
Found system not running due to loose fuse connection is air handler. I put fuse back in place. Checked operation. No further issues at this time
St. Petersburg, FL 33712
Ricky O.
Ricky O. Checked in
Bad cap for condenser fan motor. Client to replace himself
St. Petersburg, FL 33703
Reason for call:
No cool 

Summary:
Found 5 flash code at Ahu board. 
This says failed or tripped refrigerant sensor. 
Bypassed board for call for cool. For temporary cooling. 
Confirmed proper pressures stating there is no current refrigerant leak. 

Solution:
Office will confirm warranty. 
Office will provide quote for replacement of refrigerant sensor and Ahu control board. 
Solution for bypassing board for temporary cooling
Reason for call:
No cool 

Summary:
Found 5 flash code at Ahu board. 
This says failed or tripped refrigerant sensor. 
Bypassed board for call for cool. For temporary cooling. 
Confirmed proper pressures stating there is no current refrigerant leak. 

Solution:
Office will confirm warranty. 
Office will provide quote for replacement of refrigerant sensor and Ahu control board. 
Solution for bypassing board for temporary cooling
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: Found 5 flash code at Ahu board. This says failed or tripped refrigerant sensor. Bypassed board for call for cool. For temporary cooling. Confirmed proper pressures stating there is no current refrigerant leak. Solution: Office will confirm warranty. Office will provide quote for replacement of refrigerant sensor and Ahu control board. Solution for bypassing board for temporary cooling
St. Petersburg, FL 33701
Homeowner provided a new thermostat asked me to install it in programming. I did offer the homeowner on maintenance plan at the moment. He’s not interested, but he wanted to do the thermostat.
Homeowner provided a new thermostat asked me to install it in programming. I did offer the homeowner on maintenance plan at the moment. He’s not interested, but he wanted to do the thermostat.
Ace m.
Ace m. Checked in
Homeowner provided a new thermostat asked me to install it in programming. I did offer the homeowner on maintenance plan at the moment. He’s not interested, but he wanted to do the thermostat.
St. Petersburg, FL 33704
Reason for call:
No cool 

Summary:
Found failed in unit breaker. 

Bypassed breaker for temporary cooling over long weekend 

Solution:
Office will provide estimate for new breaker.
Reason for call:
No cool 

Summary:
Found failed in unit breaker. 

Bypassed breaker for temporary cooling over long weekend 

Solution:
Office will provide estimate for new breaker.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: Found failed in unit breaker. Bypassed breaker for temporary cooling over long weekend Solution: Office will provide estimate for new breaker.
St. Petersburg, FL 33702
On arrival found unit not cooling due to bad condenser fan motor. Replaced parts. Found worn contactor. Replaced part. Start and test. Pressures good. Temp split good. Rinsed condenser coil. Unit cooling. Client is aware of age of unit and is budgeting for new unit. 
Found attic encapsulated. No moisture observed at this time. Told client dehumidifier might be needed in future. Aux pan does not cover entire air handler and has potential for leaks. Client is fully aware of all issues.
On arrival found unit not cooling due to bad condenser fan motor. Replaced parts. Found worn contactor. Replaced part. Start and test. Pressures good. Temp split good. Rinsed condenser coil. Unit cooling. Client is aware of age of unit and is budgeting for new unit. 
Found attic encapsulated. No moisture observed at this time. Told client dehumidifier might be needed in future. Aux pan does not cover entire air handler and has potential for leaks. Client is fully aware of all issues.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to bad condenser fan motor. Replaced parts. Found worn contactor. Replaced part. Start and test. Pressures good. Temp split good. Rinsed condenser coil. Unit cooling. Client is aware of age of unit and is budgeting for new unit. Found attic encapsulated. No moisture observed at this time. Told client dehumidifier might be needed in future. Aux pan does not cover entire air handler and has potential for leaks. Client is fully aware of all issues.
St. Petersburg, FL 33713
Griffin K.
Griffin K. Checked in
Upon inspections customer said breaker trips randomly when the microwave starts the breaker was on when I arrived could not get it to trip again. found possible issues with circuit in outlet boxes recommended performing these services after repairs tested microwave and there was no trip told the customer to monitor it and if it happens again to call us Make connections for kitchen wiring new in box Disconnect unknown wire from the refrigerator plug and cap off Ceiling fan in office had a loose neutral wire remade up connection and breaker did not trip again and fan is working
St. Petersburg, FL 33703
How do I know if my AC needs repair or full replacement?

Our technicians inspect the full system — age, refrigerant type, corrosion, and repair history — and give you an honest recommendation. If a repair makes sense, we'll fix it. If the unit is beyond its useful life, we'll walk you through replacement options with no pressure.

Are your technicians background-checked and licensed?

Yes. Every Air Bros technician is background-checked, factory-trained, and works under our state HVAC license (#CAC1820499) and electrical license (#EC13015085).

What parts of St. Petersburg do you serve?

We serve all of St. Petersburg, including Downtown, Historic Kenwood, Old Northeast, Snell Isle, Crescent Lake, Shore Acres, and Coquina Key, plus Seminole, Largo, Pinellas Park, and the surrounding beach communities.

Do you offer same-day AC repair in St. Petersburg?

Yes. We offer 24/7 emergency AC repair with same-day service throughout St. Petersburg and the surrounding Pinellas County area.

Is Air Bros a local St. Petersburg company, or a franchise?

Air Bros is 100% locally owned and operated, headquartered in the Shore Acres neighborhood of St. Petersburg. We're not a franchise — every technician is a direct employee, not a subcontractor.

Contact the Bros You Know Today!

Gravity Forms Pagination Must be Steps