Instant Quote Shop Filters Call Air Bros

St. Petersburg, FL

air-bros-team-with-truck

The Best AC Repair in St. Petersburg, FL — From Technicians Your Neighbors Already Trust

When your AC quits in the middle of a St. Pete summer, you don't want a stranger in an unmarked van. You want a technician your neighbors already know and trust. Air Bros Air Conditioning & Electrical has been fixing air conditioners in St. Petersburg since 2020, but our roots run deeper — founder Ricky Orta grew up learning the trade from his father and has been a licensed HVAC contractor since 2006. That local, hands-on experience is why homeowners from Historic Kenwood to Snell Isle call us the best AC repair company in St. Petersburg.

We're headquartered right here in the Shore Acres neighborhood, so when you call, you're not routed to a call center — you're talking to the same local team that services your street.

Call us at 727-217-6148 or contact us online today for all of your HVAC, indoor air quality and electrical needs.

Meet the technicians who service St. Petersburg

What to expect when we show up

Calling a repair company you've never used before shouldn't feel like a gamble. Here's exactly how an Air Bros service call goes, every time.

You'll get a heads-up before we arrive, then a uniformed technician in a marked Air Bros vehicle shows up in the window we promised. We diagnose the whole system — not just the obvious symptom — then explain what we found and what your options are before any work starts. You approve the price up front, we make the repair, and we don't leave until we've confirmed the system is cooling the way it should.

Every technician is a background-checked, drug-tested Air Bros employee — never a subcontractor — and each one is trained to service every major AC and heat pump brand. It's the kind of consistency you can only get from a local team that answers to its own name.

And if something isn't right? Our 100% satisfaction guarantee means we make it right.

Signs you need AC repair

St. Petersburg's heat and humidity push air conditioners harder than almost anywhere else in the country. Call for AC repair if you notice:

  • Warm air blowing from vents, or the system running constantly without cooling
  • Water pooling around your air handler (a common issue in St. Pete's older homes with attic-run drain lines)
  • Musty odors or visible mold near vents — a sign of a clogged condensate line or dirty coil
  • Rising humidity indoors despite the AC running
  • Short cycling, tripped breakers, or a system that won't turn on at all

Our technicians diagnose the full system on every call — refrigerant charge, temperature split, electrical connections, and drain line — so you get a real fix, not a temporary patch.

Comprehensive HVAC Services in St. Petersburg

We offer a full range of heating and cooling services to keep your St. Petersburg, FL, home comfortable year-round:

  • Air Conditioning: From AC repair and AC installation to routine maintenance, we ensure your cooling system keeps you comfortable during those hot Florida summers. We offer same-day service for AC emergencies, so you never have to suffer in the heat.
  • Heating: Stay warm and cozy in the winter with our comprehensive heating services. We repair and install all types of heating systems, including furnaces and heat pumps, and offer preventative maintenance to keep your system running efficiently.
  • Indoor Air Quality: Improve your indoor air quality with our dehumidifier and UV light installation services. We'll help you control excess humidity and eliminate airborne contaminants, creating a healthier home environment.
  • Ductwork: Ensure optimal airflow and energy efficiency with our ductwork repair and installation services. We can address leaks and damage, and design a system that's perfect for your home.
  • Pool Heater Services: Extend your swim season with our pool heater installation and repair services.
  • Electrical Services: From outlet and switch replacements to ceiling fan installations to whole-house surge protector installations, we have the experts to handle your electrical service needs.

Our experienced technicians are skilled in all aspects of HVAC service and are dedicated to providing top-quality workmanship and customer care.

Why Choose Air Bros?

  • Local Expertise: We understand the unique climate challenges of St. Petersburg.
  • Fast and Reliable Service: We offer same-day service for AC emergencies and prioritize prompt service for all your HVAC needs.
  • Experienced Technicians: Our team is highly trained and experienced in all aspects of HVAC service.
  • Upfront Pricing: We provide transparent pricing with no hidden costs.
  • Customer Satisfaction Guaranteed: Your comfort and satisfaction are our top priorities.

Contact Air Bros Today!

Whether you need emergency AC repair, a new heating system installation, or any other HVAC service, Air Bros is here to help. Contact us today for a free consultation or to schedule a service appointment. We're proud to be your trusted HVAC partner in St. Petersburg!

Call us at 727-217-6148 or contact us online today!

Recent Jobs and Reviews in St. Petersburg, FL

St. Petersburg, FL at a glance

Air Bros Air Conditioning & Electrical has completed 25 jobs in St. Petersburg, FL in September 2026.

The most recent job was on September 20, 2026.

Air Bros Air Conditioning & Electrical has completed 1,919 jobs in St. Petersburg, FL in the last 12 months. The first job there was in December 2024.

Job Locations and Reviews

Reason for call:
No cool 

Summary:
On arrival found system off of safety switch. 
Found clogged drain line. 
Completed drain line cleaning to restore operation to equipment. 
Completed further inspection of equipment. 
Confirmed proper amp draws of equipment. 
Confirmed proper capacitor readings. 
Found temperature and pressures slightly low. 
Added two pounds of 410 a to bring equipment within manufacturing specifications. 
Informed homeowner that this is a top off of charge and recommended a maintenance service in 6 months to reevaluate system.
Reason for call:
No cool 

Summary:
On arrival found system off of safety switch. 
Found clogged drain line. 
Completed drain line cleaning to restore operation to equipment. 
Completed further inspection of equipment. 
Confirmed proper amp draws of equipment. 
Confirmed proper capacitor readings. 
Found temperature and pressures slightly low. 
Added two pounds of 410 a to bring equipment within manufacturing specifications. 
Informed homeowner that this is a top off of charge and recommended a maintenance service in 6 months to reevaluate system.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: On arrival found system off of safety switch. Found clogged drain line. Completed drain line cleaning to restore operation to equipment. Completed further inspection of equipment. Confirmed proper amp draws of equipment. Confirmed proper capacitor readings. Found temperature and pressures slightly low. Added two pounds of 410 a to bring equipment within manufacturing specifications. Informed homeowner that this is a top off of charge and recommended a maintenance service in 6 months to reevaluate system.
St. Petersburg, FL 33713
Reason for call:
No cool 

Summary:
Found unit operating when I arrived. 
After 15 minutes unit shut off on float switch due to clogged.
Drain line. 
Flushed drain line cleaned drain pan. 
Changed float switch wiring from y to r so that thermostat shuts off when unit trips on float switch. 
Confirmed proper temperature. 
Confirmed proper pressures.
Confirmed proper drainage. 
Filters have been maintained properly.
Reason for call:
No cool 

Summary:
Found unit operating when I arrived. 
After 15 minutes unit shut off on float switch due to clogged.
Drain line. 
Flushed drain line cleaned drain pan. 
Changed float switch wiring from y to r so that thermostat shuts off when unit trips on float switch. 
Confirmed proper temperature. 
Confirmed proper pressures.
Confirmed proper drainage. 
Filters have been maintained properly.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: Found unit operating when I arrived. After 15 minutes unit shut off on float switch due to clogged. Drain line. Flushed drain line cleaned drain pan. Changed float switch wiring from y to r so that thermostat shuts off when unit trips on float switch. Confirmed proper temperature. Confirmed proper pressures. Confirmed proper drainage. Filters have been maintained properly.
St. Petersburg, FL 33703
Reason for call:
No cool 

Summary:
Found secondary pan full of water. 
Found source of water due to the flap piece of pan that catches run off from u bends on coil had debris and was not allowing water into primary pan. 
Flush pan and drain removed traps from system
Reason for call:
No cool 

Summary:
Found secondary pan full of water. 
Found source of water due to the flap piece of pan that catches run off from u bends on coil had debris and was not allowing water into primary pan. 
Flush pan and drain removed traps from system
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: Found secondary pan full of water. Found source of water due to the flap piece of pan that catches run off from u bends on coil had debris and was not allowing water into primary pan. Flush pan and drain removed traps from system
St. Petersburg, FL 33702
Reason for call:
No cool 

Summary:
On arrival found evaporator coil frozen. 
De iced coils and operation was restored. 
Completed full diagnostic to find the equipment operating within manufacturing specifications. 
Recommended replacement of filters to improve air flow. 
Unit is cooling by 20 degree at this time.
Reason for call:
No cool 

Summary:
On arrival found evaporator coil frozen. 
De iced coils and operation was restored. 
Completed full diagnostic to find the equipment operating within manufacturing specifications. 
Recommended replacement of filters to improve air flow. 
Unit is cooling by 20 degree at this time.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: On arrival found evaporator coil frozen. De iced coils and operation was restored. Completed full diagnostic to find the equipment operating within manufacturing specifications. Recommended replacement of filters to improve air flow. Unit is cooling by 20 degree at this time.
St. Petersburg, FL 33704
Justin G.
Justin G. Checked in
Remove and replace blower motor for living room unit. Start and test. Tax and labor included. Made client aware to move sprinkler pipe to prevent water leaks. Air bros not responsible for damaged sprinkler system or water damage. Unit cooling.
St. Petersburg, FL 33701
Reason for call:
No cool, blank thermostat

Summary:
Found clogged drain line on arrival float switch was engaged. 
Clear drain line to restore operation to the equipment.
Unit is cooling by 20° temperature split
Made minor repair on disconnect box fastened to wall.
Spoke with homeowner about proper maintenance on the equipment offered the Maintenance membership program.
Unit operating within manufacturing specifications at this time.
Reason for call:
No cool, blank thermostat

Summary:
Found clogged drain line on arrival float switch was engaged. 
Clear drain line to restore operation to the equipment.
Unit is cooling by 20° temperature split
Made minor repair on disconnect box fastened to wall.
Spoke with homeowner about proper maintenance on the equipment offered the Maintenance membership program.
Unit operating within manufacturing specifications at this time.
Corbin C.
Corbin C. Checked in
Reason for call: No cool, blank thermostat Summary: Found clogged drain line on arrival float switch was engaged. Clear drain line to restore operation to the equipment. Unit is cooling by 20° temperature split Made minor repair on disconnect box fastened to wall. Spoke with homeowner about proper maintenance on the equipment offered the Maintenance membership program. Unit operating within manufacturing specifications at this time.
St. Petersburg, FL 33713
Reason for call:
Condenser breaker tripping. 

Summary:
Performed full inspection of unit to find it operating within manufacturing specifications. 
Inspected all high voltage wire on condenser. Found no damage.
Compressor is amping out properly and has proper start up amp draw. 
Found an under sized breaker on condenser circuit. Unit calling for 25 20 was installed. 
Informed homeowner of possibilities with curry line and compressor concerns 
We are starting at breaker and will proceed from there if issue persists. 

Solution:
Replace 20 amp breaker due to undersized breaker on Condneser
Reason for call:
Condenser breaker tripping. 

Summary:
Performed full inspection of unit to find it operating within manufacturing specifications. 
Inspected all high voltage wire on condenser. Found no damage.
Compressor is amping out properly and has proper start up amp draw. 
Found an under sized breaker on condenser circuit. Unit calling for 25 20 was installed. 
Informed homeowner of possibilities with curry line and compressor concerns 
We are starting at breaker and will proceed from there if issue persists. 

Solution:
Replace 20 amp breaker due to undersized breaker on Condneser
Griffin K.
Griffin K. Checked in
Reason for call: Condenser breaker tripping. Summary: Performed full inspection of unit to find it operating within manufacturing specifications. Inspected all high voltage wire on condenser. Found no damage. Compressor is amping out properly and has proper start up amp draw. Found an under sized breaker on condenser circuit. Unit calling for 25 20 was installed. Informed homeowner of possibilities with curry line and compressor concerns We are starting at breaker and will proceed from there if issue persists. Solution: Replace 20 amp breaker due to undersized breaker on Condneser
St. Petersburg, FL 33710
Upon my inspection, system is not cooling due to faulty TXV. 
Also found a very weak and out of range capacitor. 
Also found extremely dirty air filters 
Also found a dirty drain line. 

Quote sent for repairs and expedited shipping to get the repair done today. Client did not give us an answer in time. 
$195 service fee collected for today. Waiting on approval for repairs. Monday is the soonest repair day depending on time of approval. 
Turned system off by main disconnect on roof at this time to prevent system from short cycling and ruining the compressor as well.
Upon my inspection, system is not cooling due to faulty TXV. 
Also found a very weak and out of range capacitor. 
Also found extremely dirty air filters 
Also found a dirty drain line. 

Quote sent for repairs and expedited shipping to get the repair done today. Client did not give us an answer in time. 
$195 service fee collected for today. Waiting on approval for repairs. Monday is the soonest repair day depending on time of approval. 
Turned system off by main disconnect on roof at this time to prevent system from short cycling and ruining the compressor as well.
Michael A.
Michael A. Checked in
Upon my inspection, system is not cooling due to faulty TXV. Also found a very weak and out of range capacitor. Also found extremely dirty air filters Also found a dirty drain line. Quote sent for repairs and expedited shipping to get the repair done today. Client did not give us an answer in time. $195 service fee collected for today. Waiting on approval for repairs. Monday is the soonest repair day depending on time of approval. Turned system off by main disconnect on roof at this time to prevent system from short cycling and ruining the compressor as well.
St. Petersburg, FL 33713
Griffin K.
Griffin K. Checked in
Install a recessed tv box for new tv Mount customer supplied mount and tv Drywall will need to be cut to run electrical air bros is not responsible for drywall repair Plywood will need to be removed for access down the wall in attic
St. Petersburg, FL 33713
Ruud 5 ton 18 seer2 heat pump variable speed split system
5kw heater
Hurricane pad
Anchor condenser
Ruud thermostat
Horizontal attic
Aux pan
Run new 12” supply duct for mixing box
Clear drain
Safety switches
Remove existing equipment 
Connect to existing ducts and electrical 
Seal unit to code
Tax labor and permit included
0% for 18 months financing included 
10 year parts warranty 
5 year labor warranty 
Fall savings of $1000.00 applied
Price good for 7 days
Ruud 5 ton 18 seer2 heat pump variable speed split system
5kw heater
Hurricane pad
Anchor condenser
Ruud thermostat
Horizontal attic
Aux pan
Run new 12” supply duct for mixing box
Clear drain
Safety switches
Remove existing equipment 
Connect to existing ducts and electrical 
Seal unit to code
Tax labor and permit included
0% for 18 months financing included 
10 year parts warranty 
5 year labor warranty 
Fall savings of $1000.00 applied
Price good for 7 days
Martin W.
Martin W. Checked in
Ruud 5 ton 18 seer2 heat pump variable speed split system 5kw heater Hurricane pad Anchor condenser Ruud thermostat Horizontal attic Aux pan Run new 12” supply duct for mixing box Clear drain Safety switches Remove existing equipment Connect to existing ducts and electrical Seal unit to code Tax labor and permit included 0% for 18 months financing included 10 year parts warranty 5 year labor warranty Fall savings of $1000.00 applied Price good for 7 days
St. Petersburg, FL 33709
Justin G.
Justin G. Checked in
Performed maintenance on mother in law unit. Cleared drain. Rinsed condenser coil. Found weak capacitor and replaced. Electrical good. Temp split good. Unit cooling at this time.
St. Petersburg, FL 33709
Upon arrival, I began by checking the temperature split between the supply and return air, which measured 18°F, indicating normal system performance. I then inspected the electrical components and found all equipment operating within manufacturer specifications, with no components over-amping. The refrigerant cycle was checked and is operating properly.

As part of today’s maintenance, I performed a complete drain line treatment, cleaned the drain pan, cleaned the condenser coil, and completed a full air handler inspection. The system is operating properly at this time.

If you have any questions or concerns, please don’t hesitate to reach out. Thank you for your business, and have a great day
Upon arrival, I began by checking the temperature split between the supply and return air, which measured 18°F, indicating normal system performance. I then inspected the electrical components and found all equipment operating within manufacturer specifications, with no components over-amping. The refrigerant cycle was checked and is operating properly.

As part of today’s maintenance, I performed a complete drain line treatment, cleaned the drain pan, cleaned the condenser coil, and completed a full air handler inspection. The system is operating properly at this time.

If you have any questions or concerns, please don’t hesitate to reach out. Thank you for your business, and have a great day
Ace m.
Ace m. Checked in
Upon arrival, I began by checking the temperature split between the supply and return air, which measured 18°F, indicating normal system performance. I then inspected the electrical components and found all equipment operating within manufacturer specifications, with no components over-amping. The refrigerant cycle was checked and is operating properly. As part of today’s maintenance, I performed a complete drain line treatment, cleaned the drain pan, cleaned the condenser coil, and completed a full air handler inspection. The system is operating properly at this time. If you have any questions or concerns, please don’t hesitate to reach out. Thank you for your business, and have a great day
St. Petersburg, FL 33703
Reason for call:
Tune up on two systems

Summary:
Completed tune up to find both units operating within manufacturing specifications. 
Confirmed proper temperature. 
Confirmed proper amp draws. 
Flushed and cleaned indoor coils. 
Flushed and clean drain pan and drain line. 
Found one unit without a filter 18x20x1 is needed 
Found one unit with incorrect size filter 16x20x1 is needed 

Downstairs unit does have aroma 360 installed seems to be out needs new canister. 

Found failed nest stat reading incorrect temperature by 10 degrees tried to reset and adjust setting it was still reading incorrect temperatures. 

Recommended replacing both nest thermostats with eco bees. 
Provided estimate for two eco bee with install and warranty 
Provided estimate for install of client supplied thermostats.
Reason for call:
Tune up on two systems

Summary:
Completed tune up to find both units operating within manufacturing specifications. 
Confirmed proper temperature. 
Confirmed proper amp draws. 
Flushed and cleaned indoor coils. 
Flushed and clean drain pan and drain line. 
Found one unit without a filter 18x20x1 is needed 
Found one unit with incorrect size filter 16x20x1 is needed 

Downstairs unit does have aroma 360 installed seems to be out needs new canister. 

Found failed nest stat reading incorrect temperature by 10 degrees tried to reset and adjust setting it was still reading incorrect temperatures. 

Recommended replacing both nest thermostats with eco bees. 
Provided estimate for two eco bee with install and warranty 
Provided estimate for install of client supplied thermostats.
Corbin C.
Corbin C. Checked in
Reason for call: Tune up on two systems Summary: Completed tune up to find both units operating within manufacturing specifications. Confirmed proper temperature. Confirmed proper amp draws. Flushed and cleaned indoor coils. Flushed and clean drain pan and drain line. Found one unit without a filter 18x20x1 is needed Found one unit with incorrect size filter 16x20x1 is needed Downstairs unit does have aroma 360 installed seems to be out needs new canister. Found failed nest stat reading incorrect temperature by 10 degrees tried to reset and adjust setting it was still reading incorrect temperatures. Recommended replacing both nest thermostats with eco bees. Provided estimate for two eco bee with install and warranty Provided estimate for install of client supplied thermostats.
St. Petersburg, FL 33701
Reason for call:
No cool 

Summary:
Found float switch engaged and a clogged drain line. Completed drain flush and clean unit is operating with manufacturer specifications. No other concerns at this time. 
Homeowner has kept up with filters well. 
Informed homeowner to clean up the Ahu closet a little and he will be in good shape.
Reason for call:
No cool 

Summary:
Found float switch engaged and a clogged drain line. Completed drain flush and clean unit is operating with manufacturer specifications. No other concerns at this time. 
Homeowner has kept up with filters well. 
Informed homeowner to clean up the Ahu closet a little and he will be in good shape.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: Found float switch engaged and a clogged drain line. Completed drain flush and clean unit is operating with manufacturer specifications. No other concerns at this time. Homeowner has kept up with filters well. Informed homeowner to clean up the Ahu closet a little and he will be in good shape.
St. Petersburg, FL 33703
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Performed maintenance. Added chemical to pan to help prevent clogs. Rinsed condenser coil. Temp split good. Electrical checked good. Unit cooling and draining properly at this time.
St. Petersburg, FL 33707
Pull evaporator coil and replace txv. Clean coil with chemical. Replace weak capacitor and filter dryer. Pull and clean blower wheel. Reinstall parts. Pressure test and pull vacuum to remove impurities. Start and test. Tax and labor included. Perform maintenance on 2 systems.
Pull evaporator coil and replace txv. Clean coil with chemical. Replace weak capacitor and filter dryer. Pull and clean blower wheel. Reinstall parts. Pressure test and pull vacuum to remove impurities. Start and test. Tax and labor included. Perform maintenance on 2 systems.
Justin G.
Justin G. Checked in
Pull evaporator coil and replace txv. Clean coil with chemical. Replace weak capacitor and filter dryer. Pull and clean blower wheel. Reinstall parts. Pressure test and pull vacuum to remove impurities. Start and test. Tax and labor included. Perform maintenance on 2 systems.
St. Petersburg, FL 33710
Ace m.
Ace m. Checked in
Drain line treatment. System had a clogged drain line, after the treatment system turned with a 19 temperature difference Please note that the office told the homeowner that we will waive the $95 fee
St. Petersburg, FL 33714
5 ton Ruud heat pump package unit
- 10 year parts warranty
- 3 year labor warranty
- Small Crane included
___

- Replace package unit on roof top
- New Duct Shroud
- New duct connections to unit
- Upsize return if possible
- New thermostat 
- Transfer over UV system from old unit
- Install second UV system on return side of evaporator coils for additional $450 add on price. 
- New hurricane straps and seal to roof with silicone
- Existing disconnect 
- New drain line with proper p trap and slop off of roof and down wall

100% satisfaction
5 ton Ruud heat pump package unit
- 10 year parts warranty
- 3 year labor warranty
- Small Crane included
___

- Replace package unit on roof top
- New Duct Shroud
- New duct connections to unit
- Upsize return if possible
- New thermostat 
- Transfer over UV system from old unit
- Install second UV system on return side of evaporator coils for additional $450 add on price. 
- New hurricane straps and seal to roof with silicone
- Existing disconnect 
- New drain line with proper p trap and slop off of roof and down wall

100% satisfaction
Kyle K.
Kyle K. Checked in
5 ton Ruud heat pump package unit - 10 year parts warranty - 3 year labor warranty - Small Crane included ___ - Replace package unit on roof top - New Duct Shroud - New duct connections to unit - Upsize return if possible - New thermostat - Transfer over UV system from old unit - Install second UV system on return side of evaporator coils for additional $450 add on price. - New hurricane straps and seal to roof with silicone - Existing disconnect - New drain line with proper p trap and slop off of roof and down wall 100% satisfaction
St. Petersburg, FL 33710
Corbin C.
Corbin C. Checked in
Reason for call: Water leak Summary: Found water leak inside line hide cover. Mini split line came separated from pvc drain line. Completed drain repair and did minor service on unit. Flushed drain line. Cleaned filters. Cleaned coil. Unit is in great operating order. Informed homeowner of tune ups so he can get those down periodically.
St. Petersburg, FL 33713
Perform a drain line treatment, system had an 18° temperature difference. If you have any questions, please reach out thank your business. Have a great day.
Perform a drain line treatment, system had an 18° temperature difference. If you have any questions, please reach out thank your business. Have a great day.
Ace m.
Ace m. Checked in
Perform a drain line treatment, system had an 18° temperature difference. If you have any questions, please reach out thank your business. Have a great day.
St. Petersburg, FL 33704
Reason for call:
Water leak on mini split

Summary:
On arrival found unit cooling with minor drip. 
Found drain lien buried in landscaping. This cause the drain lien to back up and build up debris inside pvc line. 
Unit is working well, fairly clean, and a 20+ temperature split was present. 

Solution
Clean mini split drain line 
Perform filter cleanings 
Coil cleaning
Panel cleanings 
operational inspection
Reason for call:
Water leak on mini split

Summary:
On arrival found unit cooling with minor drip. 
Found drain lien buried in landscaping. This cause the drain lien to back up and build up debris inside pvc line. 
Unit is working well, fairly clean, and a 20+ temperature split was present. 

Solution
Clean mini split drain line 
Perform filter cleanings 
Coil cleaning
Panel cleanings 
operational inspection
Corbin C.
Corbin C. Checked in
Reason for call: Water leak on mini split Summary: On arrival found unit cooling with minor drip. Found drain lien buried in landscaping. This cause the drain lien to back up and build up debris inside pvc line. Unit is working well, fairly clean, and a 20+ temperature split was present. Solution Clean mini split drain line Perform filter cleanings Coil cleaning Panel cleanings operational inspection
St. Petersburg, FL 33704
Replace warranty control board
Replace thermostat 

Completed repair. 
Operation was restored to equipment unit has 20 degree temperature split. Unit turn on and off properly.
Replace warranty control board
Replace thermostat 

Completed repair. 
Operation was restored to equipment unit has 20 degree temperature split. Unit turn on and off properly.
Corbin C.
Corbin C. Checked in
Replace warranty control board Replace thermostat Completed repair. Operation was restored to equipment unit has 20 degree temperature split. Unit turn on and off properly.
St. Petersburg, FL 33701
8 yrs old
4 ton system in 1500 sq ft home (oversized)
No warranty
Rusted evap coils 
No primary float
Unit sweating
Dirty blower wheel
Bacterial growth throughout air handler
Inaccessible doors

Went through all options and possibilities with client and Client would only like a system replacement quote. 
Sending quote today. 
System is cooling and draining at this time. No guarantee on how long system will last.
8 yrs old
4 ton system in 1500 sq ft home (oversized)
No warranty
Rusted evap coils 
No primary float
Unit sweating
Dirty blower wheel
Bacterial growth throughout air handler
Inaccessible doors

Went through all options and possibilities with client and Client would only like a system replacement quote. 
Sending quote today. 
System is cooling and draining at this time. No guarantee on how long system will last.
Michael A.
Michael A. Checked in
8 yrs old 4 ton system in 1500 sq ft home (oversized) No warranty Rusted evap coils No primary float Unit sweating Dirty blower wheel Bacterial growth throughout air handler Inaccessible doors Went through all options and possibilities with client and Client would only like a system replacement quote. Sending quote today. System is cooling and draining at this time. No guarantee on how long system will last.
St. Petersburg, FL 33714
St. Petersburg, FL - Client states they smell an odor while the system is running. We determined together that this smell is likely from bacterial growth within the ductwork. I inspected the ductwork in the attic and found some silver flex ducks connected to old Fiberglass ductwork. Discussed options with Paul duck system air purifiers, duck, sanitation, and replacing all ductwork. Client does not want any quotes at this time until after his appointment with a duct cleaning company. Client states there have been no issues with cooling.
Ductwork does not have mastic sealant and is not strapped up. A guaranteed solution would be to replace all ductwork and install an air purifier.
Client will call back for an estimate if desired. We will not charge a service fee for an estimate.
Michael A.
Michael A. Checked in
Client states they smell an odor while the system is running. We determined together that this smell is likely from bacterial growth within the ductwork. I inspected the ductwork in the attic and found some silver flex ducks connected to old Fiberglass ductwork. Discussed options with Paul duck system air purifiers, duck, sanitation, and replacing all ductwork. Client does not want any quotes at this time until after his appointment with a duct cleaning company. Client states there have been no issues with cooling. Ductwork does not have mastic sealant and is not strapped up. A guaranteed solution would be to replace all ductwork and install an air purifier. Client will call back for an estimate if desired. We will not charge a service fee for an estimate.
St. Petersburg, FL 33703
I arrived onsite and noticed water coming from 3 vents kitchen, living room and bathroom grilles. TD on system is 19°. I then noticed bathroom has no exhaust fan and in the kitchen an old window. When client showers or on humid days, the humidity in room has no where to go. It’s hitting the grille and causing condensation. Kitchen has a big flapper window that is old and not sealed at all. Also a flat roof lanai that does not have ac. Can feel hot, humid air coming in from kitchen. Advised client to better seal home and install exhaust fan in bathroom. Client said they don’t have the funds at this time
I arrived onsite and noticed water coming from 3 vents kitchen, living room and bathroom grilles. TD on system is 19°. I then noticed bathroom has no exhaust fan and in the kitchen an old window. When client showers or on humid days, the humidity in room has no where to go. It’s hitting the grille and causing condensation. Kitchen has a big flapper window that is old and not sealed at all. Also a flat roof lanai that does not have ac. Can feel hot, humid air coming in from kitchen. Advised client to better seal home and install exhaust fan in bathroom. Client said they don’t have the funds at this time
Corbin C.
Corbin C. Checked in
I arrived onsite and noticed water coming from 3 vents kitchen, living room and bathroom grilles. TD on system is 19°. I then noticed bathroom has no exhaust fan and in the kitchen an old window. When client showers or on humid days, the humidity in room has no where to go. It’s hitting the grille and causing condensation. Kitchen has a big flapper window that is old and not sealed at all. Also a flat roof lanai that does not have ac. Can feel hot, humid air coming in from kitchen. Advised client to better seal home and install exhaust fan in bathroom. Client said they don’t have the funds at this time
St. Petersburg, FL 33714
How do I know if my AC needs repair or full replacement?

Our technicians inspect the full system — age, refrigerant type, corrosion, and repair history — and give you an honest recommendation. If a repair makes sense, we'll fix it. If the unit is beyond its useful life, we'll walk you through replacement options with no pressure.

Are your technicians background-checked and licensed?

Yes. Every Air Bros technician is background-checked, factory-trained, and works under our state HVAC license (#CAC1820499) and electrical license (#EC13015085).

What parts of St. Petersburg do you serve?

We serve all of St. Petersburg, including Downtown, Historic Kenwood, Old Northeast, Snell Isle, Crescent Lake, Shore Acres, and Coquina Key, plus Seminole, Largo, Pinellas Park, and the surrounding beach communities.

Do you offer same-day AC repair in St. Petersburg?

Yes. We offer 24/7 emergency AC repair with same-day service throughout St. Petersburg and the surrounding Pinellas County area.

Is Air Bros a local St. Petersburg company, or a franchise?

Air Bros is 100% locally owned and operated, headquartered in the Shore Acres neighborhood of St. Petersburg. We're not a franchise — every technician is a direct employee, not a subcontractor.

Contact the Bros You Know Today!

Gravity Forms Pagination Must be Steps