Air Conditioning, Heating & Electrical Repair in Seminole, FL
Air Bros has deep roots on this side of Pinellas County. Our shop sits right on 131st Street, so when your air conditioner quits on a 95-degree afternoon, help isn't coming from a call center two counties over — it's a licensed technician a few minutes down the road. We've worked on homes from the Seminole Springs and Lake Seminole neighborhoods out toward the barrier-island beaches, and we know what the heat, the salt air, and the summer storms do to a comfort system around here.
We handle the whole house, too: air conditioning, heating, indoor air quality, and the electrical work that ties it all together. One team, one number, day or night.
Call us at 727-217-6148 or reach out online — same-day service is available, and we're open around the clock.
The HVAC & Electrical Challenges We See Most in Seminole
Living a stone's throw from the Gulf is the whole point of being here. It's also hard on equipment. The problems we get called for in this part of Pinellas tend to fall into a few familiar buckets.
Salt Air Eats Coastal Systems Alive
Homes near the beaches catch a steady dose of salt-laden air, and it doesn't stay outside. It settles on condenser coils, corrodes fan motors, and works its way into outdoor electrical connections far faster than it would inland. We routinely find pitted contactors, rusted cabinets, and weak capacitors on systems that are barely a few years old. Regular coil flushing, sealed connections, and corrosion-rated parts make a real difference, which is why a maintenance plan pays for itself quickly near the water.
Humidity That Never Really Lets Up
Our subtropical air carries moisture twelve months a year, and a huge share of the "no cool" calls we run trace right back to it. A clogged condensate drain. A slime-coated drain pan. Biological growth on a blower wheel or evaporator coil that chokes airflow and pushes humidity back into the house. Left alone, that moisture turns into musty air and water damage. We clear and treat drains as part of every tune-up, and for homes that fight stubborn humidity we install whole-home dehumidifiers and UV air purification to keep coils and ducts clean.
Storms, Lightning, and Power Surges
Tampa Bay sits in one of the most lightning-prone corners of the country, and a single summer storm can send a surge through your home that fries a capacitor, a control board, or an entire electrical panel. We see the aftermath all season. Protecting a system here means more than a good warranty — it means whole-home surge protection at the panel and at the equipment. And because hurricane season is a fact of life, every system we install gets properly anchored with a code-rated pad and hurricane tie-down straps so your condenser stays put when the wind picks up.
Aging Equipment and Strained Electrical
A lot of homes around here still run older systems on their original panels and wiring. We've opened up units to find aluminum branch wiring, breakers running hot under load, and circuits that were never sized for today's demands. As neighbors add EV chargers, pool heaters, and higher-capacity AC systems, the electrical side has to keep pace — or it becomes the thing that fails next. Our licensed electricians handle panel upgrades, wiring repairs, surge protection, and EV charger installation so the whole house can keep up with the way you actually live.
What We Do for Homes in the Area
We offer a full range of comfort and electrical services, all under one roof:
- Cooling — air conditioner repair, system replacement and new installs, and ductless mini-splits for additions, garages, and rooms that never quite cool down.
- Heating — when a heater or furnace gives out on a cold snap, we handle heating repair, installation and replacement, and energy-efficient heat pumps sized for our short, mild winters.
- Indoor air quality — dehumidifiers and UV light purifiers that take on the humidity and allergens our climate throws at you.
- Ductwork — airflow and duct services that seal up energy waste and even out the hot-and-cold rooms.
- Electrical — panel and wiring work, whole-home surge protection, pool-pump and equipment circuits, and EV charger installation.
- Pool heaters — one of the most-requested services around here. We handle repair and installation so you get more months out of the pool.
- Maintenance membership — our plan keeps your system clean, caught up, and far less likely to quit on the hottest day of the year.
When something can't wait, we run 24/7 emergency service, too.
Why Neighbors Call Air Bros
- We're local, not a franchise. We live and work in the same climate you do, and we understand what coastal Pinellas does to a system.
- Day-or-night, same-day service. When you need us, we show up — fast.
- Honest, upfront pricing. You'll know the cost before we start. No mystery fees, no pressure.
- Trained, licensed technicians. HVAC and electrical work done right the first time. (License #CAC1820499 · License #EC13015085)
- 100% satisfaction, guaranteed. Your comfort is the whole job.
Get Comfortable Again
Whether it's an emergency AC repair, a new system, a surge-protection upgrade, or a pool heater that's ready for summer, we're ready to help. Call the Bros You Know and let's get your home back to comfortable.
Call 727-217-6148 or request service online today.
Recent Jobs and Reviews in Seminole, FL
Seminole, FL at a glance
Air Bros Air Conditioning & Electrical has completed 25 jobs in Seminole, FL between April 2025 and May 2025.
The most recent job was on May 30, 2025.
Air Bros Air Conditioning & Electrical has completed 143 jobs in Seminole, FL in the last 12 months. The first job there was in January 2025.
Job Locations and Reviews
No cool In cooling mode compressor will not start. Capacitor is weak- installed new capacitor, compressor still doesn’t start. Tested compressor ohms and checked continuity to ground. No reading on locked rotor amps. cooled compressor with water. Installed hard start kit- no change. Condenser is 2004 R22 and air handler is 2017 410A. R22 is no longer available and 410A systems are no longer available. The only repair option is full system replacement. Homeowner does not want system replacement estimate at this time. System is not cooling, homeowner is aware that i left the condenser breaker OFF.
On arrival found unit not cooling due to weak capacitor. Replaced part. Start and test. Pressures good. Temp split good. Unit cooling properly at this time.
No cool Upon arrival found thermostat set to off. Homeowner says system stopped cooling this morning and blows warm air. Set thermostat to cool, system runs as normal. While standing at condenser i noticed the fan motor stopped running for a few seconds then than back on. Monitored refrigerant pressures and air temp for 30 mins. System is slightly low on refrigerant but not enough to stop the system from cooking the home. Recommend replacement fan motor as it seems to be having intermittent issues. Homeowner would like to move forward with outdoor fan motor replacement. Also found weak capacitor and sent estimate for replacement. Signed up for maintenance membership.
Ruud 15 seer heat pump 10 year parts warranty 3 year labor warranty Quote is good until May 16 5 year 0% interest financing 2 stage system -Permit -Hurricane pad -Hurricane tiedowns -Electrical whip -Breakers -Coffin box with legs -Duct plenum on return up to ceiling as per code -Flush drain and Reinsulate -Thermostat -Insulate all exposed copper -Connect to existing supply plenum -100% satisfaction guarantee
Precision tune up Checked refrigerant pressures and air temp split. Tested capacitor and cleaned electrical cabinet. Cleaned and treated drain pan/ line. Filter is dirty but homeowner does not have a replacement at this time. Tested float switch. Air handler interior is clean. Removed and cleaned return grille. Homeowner is not interested in membership.
System freezing over due to air handler coils being impacted with debris. Recommend coil pull and clean. Checked starting components. Checked pressures and temp splits
Replaced bad contactor and capacitor. 5% police discount. Checked full system operation. No further issues.
Return visit- replace capacitor came back to change out weak 30+5 mfd capacitor. Tested system function after repair. Advised homeowner we will give him a call when it’s time for his next maintenance.
On arrival found unit not on. Set thermostat. Found probable cause for condenser not running is weak capacitor. Replaced part and made wire repair. Start and test. Flushed drain. Pressures good. Temp split good. Unit is cooling at this time.
On arrival found both systems with clogged drains causing units not to cool. Cleared pan and drains. Pressures good. Temp split good. Both systems are cooling properly at this time.
Upon arrival found thermostat set to off. Set system in cooling and outdoor unit is not starting. Found dead capacitor. Additionally, float switch is tripped because of clogged drain line. Homeowner decided to move forward with these repairs today. Replaced capacitor and flushed and treated drain line. Cleared water from float switch and made sure system is draining on its own. Checked refrigerant pressures and air temp.
On arrival found unit leaking from air handler from impacted coil and improper insulation on copper. Will return to perform pull and clean on blower and coil and perform maintenance on 2 systems.
Bypassed defrost board outside. Unit now running but 2007 old and recommend replacement. Client wants to leave board bypassed for now and go over replacement options. Told client no telling how long system will last
On arrival found unit not cooling due to burnt contactor. Found weak capacitor as well. Replaced part. Start and test. Pressures good. Temp split good. Unit cooling at this time.
No cool Upon arrival air handler runs condenser does not. Found power was present at defrost control board but not coming out. Replaced board. Tested system function after repair. Checked refrigerant pressures after 15 mins run time. System is running and cooling upon departure.
No cool- downstairs bedroom system. Homeowner states the system stopped cooling a few days ago. -Found emergency drain pan full of water -cleared all water from pan and cleared condensate drain line -system is low on refrigerant, which caused evap coil to freeze and that’s what filled the pan with water. -Spoke with homeowners about moving forward with leak search and repairs that will be needed- system is no longer under warranty -Homeowner would rather replace the system that try to repair. -Recharged system with 3lbs 410A- system has 20° air temp split upon departure. -Emailed system replacement estimate to homeowners daughter Kelli Musial per request
Replaced batteries in stat. Set to cool. Verified proper operation.
Performed pm on system. System is 2012 with multiple issues. Growth inside air handler, blower wheel very dirty as well as coil. Recommend cleaning and adding uv for 1,850$. Client does not wish to proceed with repairs or replacement at this time. Will want to replace in the fall.
No cool Upon arrival system is cooling. Homeowner explained that in the last 10 days the system has had intermittent issues. When the system stops cooling, she reset everything and then it works properly. checked refrigerant pressures and air temperature split. Checked air handler cleanliness. Tested capacitor and inspected all electrical components in condensing unit. Found multiple lizards in condenser electrical compartment. One lizard is behind the defrost control board. This is the most prominent issue with the system. Otherwise system is running properly. Advised homeowner. We will send her an estimate for a replacement defrost control board, but it is not guaranteed that this will stop the issue. System will still require further diagnosis after defrost control board install installation. signed up for maintenance plan today.
Water leak Homeowner has been vacuuming water out of his emergency drain pan when the secondary switch trips. Upon initial inspection found the system did not have a primary float switch installed. Instead there was a 90° PVC pipe going directly into the emergency pan which is why when the drain line cloggs, the emergency pan fills up with water. Advised the homeowner that the system should have a primary float switch installed . Homeowner decided to move forward with primary float switch installation and drain line cleaning. Blew out drain line with nitrogen. Flushed and vacuumed with hot water. Treated evaporator coil pan with viper spray and left four pan tabs. Checked refrigerant pressures after restarting the system. System is running and cooling upon departure.
On arrival found unit not cooling due to bad blower motor. Replaced 1/2hp blower motor. Start and test. Pressures good. Temp split good. Unit is cooling properly at this time.
On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Blew high pressure nitrogen through line and vacuumed. Added chemical to help prevent growth. Unit is cooling at this time.
On arrival found unit not cooling due to clogged drain. Vacuum drain and blew out with high pressure nitrogen. Drain wan still hard to clear. Recommend condensate pump in attic and primary float switch to help with drainage. Unit is cooling at this time.
Upon arrival home owner states unit is overflowing. Found drain line heavily backed up. Blew out with nitrogen and shop vacuumed line. Verified draining. Checked pressures and temp splits. Unit is cooling. UV system is currently out. Needs new bulb. Special order will call manufacture. Discounted today from 425$ to 250$
Upon arrival home owner states outdoor unit not running. Found failed capacitor and rusted contactor. Swapped components and fired up system. Found head pressure climbing. Cleaned condenser coils and added 2lbs of 410a. Cleared drain line and verified operations. Inspected breaker panel and sub panel for condenser. Air handler Filter getting sucked into coils (wrong size) Coils and blower wheel heavily impacted Impaction is causing suction pressure to show low (verified 20° split) Added 2lbs 410a complimentary (275$ Value) Flushed Drain Line Cleaned condenser coils