Griffin K.
Run a new dedicated circuit from the panel to the master bathroom for tub GFCI plugs Add a ground bar in panel for more ground space Install existing wiring into outlet box Drywall may need to be cut to run wires into the panel *** Air bros is not responsible for drywall repairs
Dunedin, FL 34698
Corbin C.
Reason for call: Member tune up Summary: Completed maintenance visit to find unit operating within the manufacturing specifications, changed filter, flushed indoor and outdoor coils, flush, drain, and drain pan, found weak capacitor, and buzzing contactor. Replaced starting components today. Solution: Replace contactor Replace capacitor 1 year parts and labor warranty on repair only
Dunedin, FL 34698
Corbin C.
Reason for call: Member tune up on 4 systems Quote unit 3 master bedroom Summary: Flushed all drain flushed all indoor and outdoor coils. Filters have been maintained properly. Unit 3 is not operating homeowner wants replacement option. All other units have 20 degree splits. Confirmed all amp draws. Confirmed all cap readings. Found weak capacitor on unit 4 blower. Replaced fan capacitor today. Please see estimate for system replacement on unit 3.
Dunedin, FL 34698
Kyle K.
Install 2.5 ton ruud heat pump 15 seer Install new vertical air handler Install 1 inch filter rack Install new aluminum air handler stand Install new condenser Install new condenser pad New Filter Drier Install Thermostat (Auto Changeover) Thermostat Wire Included Primary Float Safety Switch UV Rated Outdoor Insulation Refrigerant Locking Caps Flush Existing Refrigerant Lines Flush Drain Line Vibration Pads Hurricane Tie Down Straps Vacuum System Seal Supply/Return Plenums Remove Current Equipment Permitting 10 Year Parts Warranty 3 Year Labor Warranty 100% Satisfaction This quote included damper repair. We can cancel other sold estimates. We offer 18 month 0% financing. 5% cash discounts.
Dunedin, FL 34698
Corbin C.
Reason for call: No cool Summary: Replaced first floor damper motor due to failure. This is part of an install that we are doing on Monday. I collected 650 cash for this part of the job today. The remainder of the job will be completed on Monday. This 650 was credited to the total cost of the Install. While I was on site, I noticed the float switch was wet and the drain line was clogged. Performed drain cleaning to confirm operation of equipment until Monday. The scheduled Install day. Honeywell zone damper motor replacement
Dunedin, FL 34698
Michael A.
Pioneer mini split system: 3 heads 1 condenser. Found system low on refrigerant and freezing up. Added refrigerant to system to get back to operating pressures. Will need to return next week to perform a leak search and repair any leaks. Client would also like a quote to clean all 3 systems. Quote sent with bundle discount.
Dunedin, FL 34698
Michael A.
Upon my inspection, found system not cooling due to a bad capacitor. Recommended replacing the capacitor and contactar as they work together to energize the condenser. Client would only like to replace the capacitor at this time. Replaced capacitor and checked system amp draws and temperature splits. System is now operating within acceptable ranges. Drain line is not backed up at this time
Dunedin, FL 34698
Corbin C.
Reason for call: No cool Equipment: 2010 rheem Horizontal in attic Condenser on left side of building Summary: Found breaker on disconnect failed 240v into disconnect 8v coming out. Solution: Install new disconnect on condenser Continued diagnosis to find system operating within manufacturing range. Unit is on borrowed time please prepare for replacement.
Dunedin, FL 34698
Michael A.
Upon my inspection, found severely clogged drain line. Performed a level two drain cleaning and treatment. I warned Client that the drain line is very very clogged up and could require a level three treatment. After completing the cleaning. I tested the drain line with 3 gallons of water. System is cooling at this time with a 20° temperature split good amp draws. Coils are clean, blower wheel is clean. I checked the capacitor and found the capacitor out of its tolerance range on the fan side and the compressor side is close. Client would like to leave the capacitor at this time.
Dunedin, FL 34698
Corbin C.
Reason for call: Miscellaneous Equipment: 2018 Goodman 2 ton Vertical and second story closet Condenser outback Summary: On arrival, homeowner told me she had damper issues. Upon further inspection, I found the downstairs damper staying open 3/4 of the way, even when power is supplied to close the damper. These are normally open dampers this damper motor has failed. We need to replace one damper motor supplying the bottom floor. There was another damper that was not hooked up. We are going to remove the damper so that they can have flow to a major 10 inch supply above the stair staircase. Upon further inspection, homeowner had told me that somebody topped off refrigerant last week hooked up my gauges to check pressures to find the system was low again with the system becoming low in such a short time there's a major leak within the system. I performed a leak search for free found leak in evaporator coil/ txv. Both these components will need to be replaced. Homeowner signed up on
Dunedin, FL 34698
Michael A.
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. System only has secondary safety float switch and no primary. Let client know that this is allowing for garage air to enter the home. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Contactar is buzzing and showing signs of potential failure/shorting out. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. Client would like to leave everything as is at this time.
Dunedin, FL 34698
Corbin C.
Reason for call: No cool Equipment: Mismatch equipment 2015 Ahu 2018 cu 3 ton Icp Summary: On arrival found system cooling by 4 degrees. Hooked gauges up to see pressures not proper. The compressor valves are bypassing causing a very high suction pressure. Compressor will need to be replace to restore operation. Informed current homeowner of this and informed her of the benefits of replacement. She want both options. Home is under contract to be sold. If replacement is chosen be sure to register under new homeowner. If repair is sold current homeowner will pay.
Dunedin, FL 34698
Corbin C.
Reason for call: No cool in both units Only one unit was down today. Unit 2 was just struggling to keep up with the heat load Equipment: Unit 1 5 ton 2020 package unit Unit 2 3 ton 2022 package unit Summary: Found unit 1 break to condenser tripped. Isolating the compressor and the disconnect the breaker tripped in compressor during diagnostic. Confirmed compressor was shorted to ground. Found unit to to be operating well just struggling to keep up. Confirmed 49 degree Evap coil temp. Solution: Providing client with two estimates in the am.
Dunedin, FL 34698
Corbin C.
Reason for call: Miscellaneous Equipment: 2022 ICP 3 ton Horizontal in attic Condenser on right side of property Summary: Completed full diagnostic found equipment operating within manufacturing specifications. Confirmed pressures, temperatures, capacitor readings, and amp draws. Unit has not been filtered. Homeowner needs to purchase 20 x 20 by one filters. To install in 1 inch filter rack at the bottom of the air handler. Solution: Sold membership, flush drain line as a courtesy today, will need to go back later to install filter. Homeowner purchases. Make it last call today on the way home.
Dunedin, FL 34698
Ricky O.
2.5 Ton Heat Pump 2 stage cooling RUUD system ~ 10 Year parts warranty ~ 3 year Labor warranty - Installation of vertical air handler in closet - New thermostat (WiFi compatible) - New safety float switch - New insulation on copper - Installation of Condenser unit - New a hurricane concrete pad - New Hurricane straps - New UV rated insulation on copper - New filter line dryer - Completed to code 100% satisfaction Permit included
Dunedin, FL 34698
Michael A.
Found restriction in system. Quote for system replacement accepted. Will return tomorrow to install. Waiving leak search fee with system replacement and unable to detect leak.
Dunedin, FL 34698
Corbin C.
Reason for call: Water leak Equipment: 2015 Goodman Horizontal in garage Condenser right of home Summary: Found water leak coming from water heater supply pipe. Homeowners will need to contact a plumber. Inspected ac unit while I was here to find pressures slightly low. And a dirty blower assembly. Recommended these repairs to client. They are only focused on the water leak today and do not want to proceed with a repair.
Dunedin, FL 34698
Justin G.
Found burnt fuse on arrival. Found a couple shorting in the low voltage wire made repairs and replaced fuse to find that the system is still off on low voltage. During diagnostics transformer failed. Did not have part on truck we will be sending another technician out later in the day with correct components.
Dunedin, FL 34698
Justin G.
Replace reversing valve coil. Start and test. Pressures good. Temp split good. Rinsed condenser coil. Unit cooling at this time.
Dunedin, FL 34698
Michael A.
Found bad indoor blower motor. Quote sent for system replacement.
Dunedin, FL 34698
Michael A.
Replaced control relay. System is functioning properly at this time.
Dunedin, FL 34698
Nathan A.
3.5 ton Ruud 16 seer heat pump 2 stage compressor 10 year parts warranty 5 year labor warranty -Hurricane pad -Tiedowns -UV rated armorflex -Replace breakers as needed -Drain pan -Safeties -UV light -WiFi thermostat -More airflow to back bedrooms -Seal to existing plenums -Flush drain -Vacuum lines under 500 microns -Start up and verified proper operation Extra System
Dunedin, FL 34698
Michael A.
Upon my inspection, found error codes on Trane communicating inverter system. Air handler error: ALERT 1 AFC CNT FLT-EVC Condenser CDV error: Unit Bus com error Found corrosion on inverter control board at condenser unit. Noticed snake skin, mud robber nest, and the smell of something dead behind the control board cover. The corrosion was present on the CDV plug as well as further down the board. Cleaned off corrosion carefully with finger and restarted the whole system. Went through all other error codes with service manual. Cleared all codes out of history. System is cooling with good pressures and a 23° temperature split at this time. Verified all components are communicating properly at this time. If problem occurs again, possible control board replacement or system replacement given the age of the system and cost of a new board out of warranty. Model# 4TWV8024A1000BA Serial # 16083L931F
Dunedin, FL 34698
Michael A.
Upon my inspection, I found a clogged drain line/drain pan. Also found severely debris impacted condenser coils. Performed proper drain cleaning and condenser coil deep clean on system. Removed indoor casing on unit and cleaned as well complimentary. Cleaned air filters. System is now draining properly. Recommended evaporator coil cleaning due to smoke residue all over coils. Client would like to wait at this time. Sending quotes for evaporator coil cleaning as well as a bundle deal for the remaining condenser coils on the house.
Dunedin, FL 34698
Michael A.
Performed an in place evaporator coil clean. Replaced UV insulation and indoor insulation on suction lines. Charge system with 2 pounds of refrigerant. Achieved a superheat of 6 to 8°. System is cooling properly at this time. Next maintenance will check pressures to determine if there is a leak within the system. System temperature split is 20°.
Dunedin, FL 34698