Recent Jobs and Reviews in Dunedin, FL

Job Locations and Reviews

Reason for call:
Miscellaneous

Equipment:
2018 Goodman 2 ton 
Vertical and second story closet
Condenser outback

Summary:
On arrival, homeowner told me she had damper issues. Upon further inspection, I found the downstairs damper staying open 3/4 of the way, even when power is supplied to close the damper. These are normally open dampers this damper motor has failed. We need to replace one damper motor supplying the bottom floor. There was another damper that was not hooked up. We are going to remove the damper so that they can have flow to a major 10 inch supply above the stair staircase.

Upon further inspection, homeowner had told me that somebody topped off refrigerant last week hooked up my gauges to check pressures to find the system was low again with the system becoming low in such a short time there's a major leak within the system. I performed a leak search for free found leak in evaporator coil/ txv. 
Both these components will need to be replaced. 

Homeowner signed up on
Reason for call:
Miscellaneous

Equipment:
2018 Goodman 2 ton 
Vertical and second story closet
Condenser outback

Summary:
On arrival, homeowner told me she had damper issues. Upon further inspection, I found the downstairs damper staying open 3/4 of the way, even when power is supplied to close the damper. These are normally open dampers this damper motor has failed. We need to replace one damper motor supplying the bottom floor. There was another damper that was not hooked up. We are going to remove the damper so that they can have flow to a major 10 inch supply above the stair staircase.

Upon further inspection, homeowner had told me that somebody topped off refrigerant last week hooked up my gauges to check pressures to find the system was low again with the system becoming low in such a short time there's a major leak within the system. I performed a leak search for free found leak in evaporator coil/ txv. 
Both these components will need to be replaced. 

Homeowner signed up on
Corbin C.
Corbin C. Checked in
Reason for call: Miscellaneous Equipment: 2018 Goodman 2 ton Vertical and second story closet Condenser outback Summary: On arrival, homeowner told me she had damper issues. Upon further inspection, I found the downstairs damper staying open 3/4 of the way, even when power is supplied to close the damper. These are normally open dampers this damper motor has failed. We need to replace one damper motor supplying the bottom floor. There was another damper that was not hooked up. We are going to remove the damper so that they can have flow to a major 10 inch supply above the stair staircase. Upon further inspection, homeowner had told me that somebody topped off refrigerant last week hooked up my gauges to check pressures to find the system was low again with the system becoming low in such a short time there's a major leak within the system. I performed a leak search for free found leak in evaporator coil/ txv. Both these components will need to be replaced. Homeowner signed up on
Dunedin, FL 34698
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. System only has secondary safety float switch and no primary. Let client know that this is allowing for garage air to enter the home. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Contactar is buzzing and showing signs of potential failure/shorting out. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.
Client would like to leave everything as is at this time.
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. System only has secondary safety float switch and no primary. Let client know that this is allowing for garage air to enter the home. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Contactar is buzzing and showing signs of potential failure/shorting out. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.
Client would like to leave everything as is at this time.
Michael A.
Michael A. Checked in
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. System only has secondary safety float switch and no primary. Let client know that this is allowing for garage air to enter the home. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Contactar is buzzing and showing signs of potential failure/shorting out. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. Client would like to leave everything as is at this time.
Dunedin, FL 34698
Reason for call:
No cool 

Equipment:
Mismatch equipment
2015 Ahu 
2018 cu 3 ton Icp

Summary:
On arrival found system cooling by 4 degrees. Hooked gauges up to see pressures not proper. The compressor valves are bypassing causing a very high suction pressure. Compressor will need to be replace to restore operation. 
Informed current homeowner of this and informed her of the benefits of replacement. She want both options. Home is under contract to be sold. If replacement is chosen be sure to register under new homeowner. If repair is sold current homeowner will pay.
Reason for call:
No cool 

Equipment:
Mismatch equipment
2015 Ahu 
2018 cu 3 ton Icp

Summary:
On arrival found system cooling by 4 degrees. Hooked gauges up to see pressures not proper. The compressor valves are bypassing causing a very high suction pressure. Compressor will need to be replace to restore operation. 
Informed current homeowner of this and informed her of the benefits of replacement. She want both options. Home is under contract to be sold. If replacement is chosen be sure to register under new homeowner. If repair is sold current homeowner will pay.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Equipment: Mismatch equipment 2015 Ahu 2018 cu 3 ton Icp Summary: On arrival found system cooling by 4 degrees. Hooked gauges up to see pressures not proper. The compressor valves are bypassing causing a very high suction pressure. Compressor will need to be replace to restore operation. Informed current homeowner of this and informed her of the benefits of replacement. She want both options. Home is under contract to be sold. If replacement is chosen be sure to register under new homeowner. If repair is sold current homeowner will pay.
Dunedin, FL 34698
Reason for call:
No cool in both units 

Only one unit was down today. 
Unit 2 was just struggling to keep up with the heat load 

Equipment:
Unit 1 
5 ton 2020 package unit 

Unit 2 
3 ton 2022 package unit 

Summary:
Found unit 1 break to condenser tripped. Isolating the compressor and the disconnect the breaker tripped in compressor during diagnostic. Confirmed compressor was shorted to ground. 

Found unit to to be operating well just struggling to keep up. Confirmed 49 degree Evap coil temp. 


Solution:
Providing client with two estimates in the am.
Reason for call:
No cool in both units 

Only one unit was down today. 
Unit 2 was just struggling to keep up with the heat load 

Equipment:
Unit 1 
5 ton 2020 package unit 

Unit 2 
3 ton 2022 package unit 

Summary:
Found unit 1 break to condenser tripped. Isolating the compressor and the disconnect the breaker tripped in compressor during diagnostic. Confirmed compressor was shorted to ground. 

Found unit to to be operating well just struggling to keep up. Confirmed 49 degree Evap coil temp. 


Solution:
Providing client with two estimates in the am.
Corbin C.
Corbin C. Checked in
Reason for call: No cool in both units Only one unit was down today. Unit 2 was just struggling to keep up with the heat load Equipment: Unit 1 5 ton 2020 package unit Unit 2 3 ton 2022 package unit Summary: Found unit 1 break to condenser tripped. Isolating the compressor and the disconnect the breaker tripped in compressor during diagnostic. Confirmed compressor was shorted to ground. Found unit to to be operating well just struggling to keep up. Confirmed 49 degree Evap coil temp. Solution: Providing client with two estimates in the am.
Dunedin, FL 34698
Reason for call:
Miscellaneous

Equipment:
2022 ICP 3 ton
Horizontal in attic
Condenser on right side of property

Summary:
Completed full diagnostic found equipment operating within manufacturing specifications. Confirmed pressures, temperatures, capacitor readings, and amp draws. Unit has not been filtered. Homeowner needs to purchase 20 x 20 by one filters. To install in 1 inch filter rack at the bottom of the air handler. 

Solution:
Sold membership, flush drain line as a courtesy today, will need to go back later to install filter. Homeowner purchases. Make it last call today on the way home.
Reason for call:
Miscellaneous

Equipment:
2022 ICP 3 ton
Horizontal in attic
Condenser on right side of property

Summary:
Completed full diagnostic found equipment operating within manufacturing specifications. Confirmed pressures, temperatures, capacitor readings, and amp draws. Unit has not been filtered. Homeowner needs to purchase 20 x 20 by one filters. To install in 1 inch filter rack at the bottom of the air handler. 

Solution:
Sold membership, flush drain line as a courtesy today, will need to go back later to install filter. Homeowner purchases. Make it last call today on the way home.
Corbin C.
Corbin C. Checked in
Reason for call: Miscellaneous Equipment: 2022 ICP 3 ton Horizontal in attic Condenser on right side of property Summary: Completed full diagnostic found equipment operating within manufacturing specifications. Confirmed pressures, temperatures, capacitor readings, and amp draws. Unit has not been filtered. Homeowner needs to purchase 20 x 20 by one filters. To install in 1 inch filter rack at the bottom of the air handler. Solution: Sold membership, flush drain line as a courtesy today, will need to go back later to install filter. Homeowner purchases. Make it last call today on the way home.
Dunedin, FL 34698
 2.5 Ton Heat Pump 2 stage cooling RUUD system 
~ 10 Year parts warranty  
~ 3 year Labor warranty
- Installation of vertical air handler in closet
- New thermostat (WiFi compatible)
- New safety float switch
- New insulation on copper
- Installation of Condenser unit
- New a hurricane concrete pad
- New Hurricane straps
- New UV rated insulation on copper
- New filter line dryer
- Completed to code
100% satisfaction
Permit included
 2.5 Ton Heat Pump 2 stage cooling RUUD system 
~ 10 Year parts warranty  
~ 3 year Labor warranty
- Installation of vertical air handler in closet
- New thermostat (WiFi compatible)
- New safety float switch
- New insulation on copper
- Installation of Condenser unit
- New a hurricane concrete pad
- New Hurricane straps
- New UV rated insulation on copper
- New filter line dryer
- Completed to code
100% satisfaction
Permit included
Ricky O.
Ricky O. Checked in
2.5 Ton Heat Pump 2 stage cooling RUUD system ~ 10 Year parts warranty ~ 3 year Labor warranty - Installation of vertical air handler in closet - New thermostat (WiFi compatible) - New safety float switch - New insulation on copper - Installation of Condenser unit - New a hurricane concrete pad - New Hurricane straps - New UV rated insulation on copper - New filter line dryer - Completed to code 100% satisfaction Permit included
Dunedin, FL 34698
Found restriction in system. Quote for system replacement accepted. Will return tomorrow to install. 
Waiving leak search fee with system replacement and unable to detect leak.
Found restriction in system. Quote for system replacement accepted. Will return tomorrow to install. 
Waiving leak search fee with system replacement and unable to detect leak.
Michael A.
Michael A. Checked in
Found restriction in system. Quote for system replacement accepted. Will return tomorrow to install. Waiving leak search fee with system replacement and unable to detect leak.
Dunedin, FL 34698
Reason for call:
Water leak 

Equipment:
2015 Goodman 
Horizontal in garage 
Condenser right of home 

Summary:
Found water leak coming from water heater supply pipe. Homeowners will need to contact a plumber. Inspected ac unit while I was here to find pressures slightly low. And a dirty blower assembly. Recommended these repairs to client. They are only focused on the water leak today and do not want to proceed with a repair.
Reason for call:
Water leak 

Equipment:
2015 Goodman 
Horizontal in garage 
Condenser right of home 

Summary:
Found water leak coming from water heater supply pipe. Homeowners will need to contact a plumber. Inspected ac unit while I was here to find pressures slightly low. And a dirty blower assembly. Recommended these repairs to client. They are only focused on the water leak today and do not want to proceed with a repair.
Corbin C.
Corbin C. Checked in
Reason for call: Water leak Equipment: 2015 Goodman Horizontal in garage Condenser right of home Summary: Found water leak coming from water heater supply pipe. Homeowners will need to contact a plumber. Inspected ac unit while I was here to find pressures slightly low. And a dirty blower assembly. Recommended these repairs to client. They are only focused on the water leak today and do not want to proceed with a repair.
Dunedin, FL 34698
Found burnt fuse on arrival. Found a couple shorting in the low voltage wire made repairs and replaced fuse to find that the system is still off on low voltage. During diagnostics transformer failed. Did not have part on truck we will be sending another technician out later in the day with correct components.
Found burnt fuse on arrival. Found a couple shorting in the low voltage wire made repairs and replaced fuse to find that the system is still off on low voltage. During diagnostics transformer failed. Did not have part on truck we will be sending another technician out later in the day with correct components.
Justin G.
Justin G. Checked in
Found burnt fuse on arrival. Found a couple shorting in the low voltage wire made repairs and replaced fuse to find that the system is still off on low voltage. During diagnostics transformer failed. Did not have part on truck we will be sending another technician out later in the day with correct components.
Dunedin, FL 34698
Dunedin, FL - Replace reversing valve coil. Start and test. Pressures good. Temp split good. Rinsed condenser coil. Unit cooling at this time.
Justin G.
Justin G. Checked in
Replace reversing valve coil. Start and test. Pressures good. Temp split good. Rinsed condenser coil. Unit cooling at this time.
Dunedin, FL 34698
Michael A.
Michael A. Checked in
Found bad indoor blower motor. Quote sent for system replacement.
Dunedin, FL 34698
Michael A.
Michael A. Checked in
Replaced control relay. System is functioning properly at this time.
Dunedin, FL 34698
3.5 ton Ruud 16 seer heat pump
2 stage compressor
10 year parts warranty
5 year labor warranty
-Hurricane pad
-Tiedowns
-UV rated armorflex
-Replace breakers as needed
-Drain pan
-Safeties
-UV light
-WiFi thermostat 
-More airflow to back bedrooms
-Seal to existing plenums
-Flush drain
-Vacuum lines under 500 microns
-Start up and verified proper operation

Extra
System
3.5 ton Ruud 16 seer heat pump
2 stage compressor
10 year parts warranty
5 year labor warranty
-Hurricane pad
-Tiedowns
-UV rated armorflex
-Replace breakers as needed
-Drain pan
-Safeties
-UV light
-WiFi thermostat 
-More airflow to back bedrooms
-Seal to existing plenums
-Flush drain
-Vacuum lines under 500 microns
-Start up and verified proper operation

Extra
System
Nathan A.
Nathan A. Checked in
3.5 ton Ruud 16 seer heat pump 2 stage compressor 10 year parts warranty 5 year labor warranty -Hurricane pad -Tiedowns -UV rated armorflex -Replace breakers as needed -Drain pan -Safeties -UV light -WiFi thermostat -More airflow to back bedrooms -Seal to existing plenums -Flush drain -Vacuum lines under 500 microns -Start up and verified proper operation Extra System
Dunedin, FL 34698
Upon my inspection, found error codes on Trane communicating inverter system. 
Air handler error: ALERT 1 AFC CNT FLT-EVC
Condenser CDV error: Unit Bus com error
Found corrosion on inverter control board at condenser unit. Noticed snake skin, mud robber nest, and the smell of something dead behind the control board cover. The corrosion was present on the CDV plug as well as further down the board. 
Cleaned off corrosion carefully with finger and restarted the whole system. Went through all other error codes with service manual. Cleared all codes out of history. System is cooling with good pressures and a 23° temperature split at this time. Verified all components are communicating properly at this time.  If problem occurs again, possible control board replacement or system replacement given the age of the system and cost of a new board out of warranty. 
Model# 4TWV8024A1000BA
Serial # 16083L931F
Upon my inspection, found error codes on Trane communicating inverter system. 
Air handler error: ALERT 1 AFC CNT FLT-EVC
Condenser CDV error: Unit Bus com error
Found corrosion on inverter control board at condenser unit. Noticed snake skin, mud robber nest, and the smell of something dead behind the control board cover. The corrosion was present on the CDV plug as well as further down the board. 
Cleaned off corrosion carefully with finger and restarted the whole system. Went through all other error codes with service manual. Cleared all codes out of history. System is cooling with good pressures and a 23° temperature split at this time. Verified all components are communicating properly at this time.  If problem occurs again, possible control board replacement or system replacement given the age of the system and cost of a new board out of warranty. 
Model# 4TWV8024A1000BA
Serial # 16083L931F
Michael A.
Michael A. Checked in
Upon my inspection, found error codes on Trane communicating inverter system. Air handler error: ALERT 1 AFC CNT FLT-EVC Condenser CDV error: Unit Bus com error Found corrosion on inverter control board at condenser unit. Noticed snake skin, mud robber nest, and the smell of something dead behind the control board cover. The corrosion was present on the CDV plug as well as further down the board. Cleaned off corrosion carefully with finger and restarted the whole system. Went through all other error codes with service manual. Cleared all codes out of history. System is cooling with good pressures and a 23° temperature split at this time. Verified all components are communicating properly at this time. If problem occurs again, possible control board replacement or system replacement given the age of the system and cost of a new board out of warranty. Model# 4TWV8024A1000BA Serial # 16083L931F
Dunedin, FL 34698
Upon my inspection, I found a clogged drain line/drain pan. Also found severely debris impacted condenser coils. Performed proper drain cleaning and condenser coil deep clean on system. Removed indoor casing on unit and cleaned as well complimentary. Cleaned air filters. System is now draining properly. Recommended evaporator coil cleaning due to smoke residue all over coils. Client would like to wait at this time. 

Sending quotes for evaporator coil cleaning as well as a bundle deal for the remaining condenser coils on the house.
Upon my inspection, I found a clogged drain line/drain pan. Also found severely debris impacted condenser coils. Performed proper drain cleaning and condenser coil deep clean on system. Removed indoor casing on unit and cleaned as well complimentary. Cleaned air filters. System is now draining properly. Recommended evaporator coil cleaning due to smoke residue all over coils. Client would like to wait at this time. 

Sending quotes for evaporator coil cleaning as well as a bundle deal for the remaining condenser coils on the house.
Michael A.
Michael A. Checked in
Upon my inspection, I found a clogged drain line/drain pan. Also found severely debris impacted condenser coils. Performed proper drain cleaning and condenser coil deep clean on system. Removed indoor casing on unit and cleaned as well complimentary. Cleaned air filters. System is now draining properly. Recommended evaporator coil cleaning due to smoke residue all over coils. Client would like to wait at this time. Sending quotes for evaporator coil cleaning as well as a bundle deal for the remaining condenser coils on the house.
Dunedin, FL 34698
Performed an in place evaporator coil clean. Replaced UV insulation and indoor insulation on suction lines. Charge system with 2 pounds of refrigerant. Achieved a superheat of 6 to 8°. System is cooling properly at this time. Next maintenance will check pressures to determine if there is a leak within the system. System temperature split is 20°.
Performed an in place evaporator coil clean. Replaced UV insulation and indoor insulation on suction lines. Charge system with 2 pounds of refrigerant. Achieved a superheat of 6 to 8°. System is cooling properly at this time. Next maintenance will check pressures to determine if there is a leak within the system. System temperature split is 20°.
Michael A.
Michael A. Checked in
Performed an in place evaporator coil clean. Replaced UV insulation and indoor insulation on suction lines. Charge system with 2 pounds of refrigerant. Achieved a superheat of 6 to 8°. System is cooling properly at this time. Next maintenance will check pressures to determine if there is a leak within the system. System temperature split is 20°.
Dunedin, FL 34698
Ricky O.
Ricky O. Checked in
Replaced oem motor and added surge pro to air handler and condenser.
Dunedin, FL 34698
no cool
Upon arrival, tenant explained that on Friday after storm system stopped cooling.
found thermostat set to off
Set thermostat in cooling and found that blower and outdoor fan motor run but compressor does not
Found dead capacitor
Installed new 40+5 mfd capacitor and compressor runs as normal
Took air temperature and checked refrigerant pressures.
System is running and cooling at this time.
Advised homeowner the air handler does have microbial growth on the interior and could use cleaning. Outdoor unit also needs maintenance. Recommend recommended maintenance membership for both systems.
no cool
Upon arrival, tenant explained that on Friday after storm system stopped cooling.
found thermostat set to off
Set thermostat in cooling and found that blower and outdoor fan motor run but compressor does not
Found dead capacitor
Installed new 40+5 mfd capacitor and compressor runs as normal
Took air temperature and checked refrigerant pressures.
System is running and cooling at this time.
Advised homeowner the air handler does have microbial growth on the interior and could use cleaning. Outdoor unit also needs maintenance. Recommend recommended maintenance membership for both systems.
Sha’nya B.
Sha’nya B. Checked in
no cool Upon arrival, tenant explained that on Friday after storm system stopped cooling. found thermostat set to off Set thermostat in cooling and found that blower and outdoor fan motor run but compressor does not Found dead capacitor Installed new 40+5 mfd capacitor and compressor runs as normal Took air temperature and checked refrigerant pressures. System is running and cooling at this time. Advised homeowner the air handler does have microbial growth on the interior and could use cleaning. Outdoor unit also needs maintenance. Recommend recommended maintenance membership for both systems.
Dunedin, FL 34698

Contact the Bros You Know Today!

Schedule Service Online
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at 727-217-6148 .

By pressing Submit I agree to receive phone, email, or text messages from Air Bros Air Conditioning & Heating to the provided mobile number and also agree to the Air Bros Air Conditioning & Heating terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next