Instant Quote Shop Filters Call Air Bros

Clearwater, FL

air-bros-team-with-truck

Expert Cooling, Heating and Electrical In Clearwater, FL

If you've lived in Clearwater for any length of time, you already know what August feels like when the AC goes out. It's not just uncomfortable — it's the kind of heat that makes an hour feel like a day. We started Air Bros because we grew up here, and we got tired of seeing neighbors get burned by out-of-town companies that didn't understand the difference between a Phoenix summer and a Gulf Coast one.

Clearwater's combination of salt air, nine months of cooling season, and humidity that rarely lets up puts real stress on HVAC equipment. We know this market, we know these homes, and we've seen firsthand what happens when the wrong company installs the wrong system for this climate. We're here to make sure that doesn't happen to you.

Professional AC Repair in Clearwater

When your AC stops working in Clearwater, waiting isn't an option. Temperatures and humidity make an uncomfortable home unbearable within hours, and in the middle of summer, same-day availability matters more than almost anything else.

Air Bros offers same-day Air Conditioning Repair throughout Clearwater and Clearwater Beach for all major brands and models. Our technicians diagnose and repair refrigerant leaks, failed capacitors, frozen evaporator coils, blower motor failures, faulty thermostats, and electrical faults. We arrive with a fully stocked truck so most repairs are completed in a single visit.

Homes near the Gulf are exposed to salt air that corrodes coil fins and electrical contacts faster than inland properties. We inspect for corrosion damage on every repair call and address it before it leads to a larger failure. All pricing is upfront and flat-rate before any work begins — no surprises when the job is done.

The Importance of Proper AC Installation

Choosing the right AC system for a Clearwater home requires more than picking a brand. It requires sizing the unit correctly for Florida's Climate Zone 2 and selecting equipment built to handle high humidity and extended run times. These are decisions that affect how comfortable your home feels and how much you spend on energy bills for the next decade.

An undersized system will run constantly without ever adequately dehumidifying your home. An oversized system will short-cycle, leaving excess moisture in the air and wearing out components prematurely. Either way, the wrong size costs you money every month and shortens the life of your equipment.

Air Bros installs Trane, Carrier, Lennox, and Daikin systems selected specifically for Gulf Coast performance. We recommend variable-speed compressors that manage humidity more effectively than single-stage units and run more quietly and efficiently over the long haul. Every AC System Replacement is permitted through Pinellas County and completed to Florida building code. We also walk you through available financing options and energy efficiency incentives before any contract is signed.

Why AC Maintenance in Clearwater is Paramount

In most of the country, annual AC maintenance is considered sufficient. In Clearwater, twice a year is the standard — and for good reason.

With a cooling season that runs from March through November, your system accumulates wear, dirt, and biological growth at a pace that a single annual visit can't keep up with. Neglected drain lines back up and cause water damage. Dirty coils make your system work harder and drive up your electric bill. Small issues that a technician would catch in April become expensive failures in July. Air Bros recommends a spring tune-up before peak cooling demand and a fall visit before humidity season winds down.

Each HVAC Maintenance visit includes coil cleaning, refrigerant level check, electrical inspection, condensate drain flush, and a corrosion assessment for properties near the water. For vacation rental owners and property managers on Clearwater Beach, we offer preventive maintenance contracts to reduce the risk of mid-booking breakdowns.

For homeowners who want year-round peace of mind, the Air Bros Premium Membership covers both visits for just $18 per month. Members pay no service call fees, get 10% off all repairs, have no overtime charges, and move to the front of the line with priority booking. In a market where a mid-August breakdown means competing with every other Clearwater home for a same-day technician, that priority access alone is worth it. If you're tired of reacting to problems and ready to get ahead of them, the membership is the most cost-effective way to keep your system running through whatever the Gulf Coast throws at it.

Why Clearwater Homeowners Choose Air Bros

We pull permits on every installation through Pinellas County, which protects your home's value and ensures your system is installed to code. Our pricing is upfront and flat-rate — you'll know the full cost before we start, with no surprise charges after the job is done.

Emergency service is available around the clock, including weekends and holidays, because AC failures don't wait for business hours. We service hundreds of beach properties annually and know exactly how to protect equipment from salt air corrosion and Florida humidity. When you call Air Bros, you're talking to someone who knows Clearwater — not a call center routing your ticket to whoever is available. If you have questions about our services, visit our HVAC FAQs page or contact us directly.

Clearwater's climate doesn't give your AC a break, and neither do we. Whether you're dealing with an unexpected breakdown, planning a new installation, or just staying ahead of the season, Air Bros is built for exactly this market. We've earned the trust of Clearwater homeowners by showing up on time, pricing honestly, and doing the job right the first time.

If you need AC Repair, AC Installation, or AC Maintenance, you can rely on Air Bros to take care of Clearwater. Call us today at 727-217-6148 to schedule your appointment.

How often should I service my AC in Clearwater, FL?

In Clearwater and throughout Florida, HVAC systems should be serviced twice per year — once in spring before the heavy cooling season, and once in fall. Florida's near-continuous cooling demand and high humidity place significantly more stress on AC systems than in northern states, making semi-annual maintenance essential rather than optional.

Why do AC systems near Clearwater Beach fail faster?

Properties within a few miles of the Gulf are exposed to salt air that accelerates corrosion on condenser coils, copper lines, and electrical contacts. This can reduce equipment lifespan by three to five years compared to inland Clearwater homes. Annual coil cleaning and corrosion-resistant coatings cost far less than early system replacement.

What HVAC brands work best in Clearwater's humid climate?

For Clearwater's high humidity and long cooling seasons, systems with strong dehumidification performance are the priority. Top performers include Trane, Carrier, Lennox, and Daikin — all offering units rated for Florida's Climate Zone 2. Variable-speed compressors are especially effective at controlling indoor humidity in Gulf Coast climates.

Do you service vacation rental properties in Clearwater Beach?

Yes. We work with many vacation rental owners and property managers throughout Clearwater Beach and the barrier islands. We prioritize fast turnaround on rental properties and offer preventive maintenance contracts to reduce mid-booking breakdowns.

Does humidity in Clearwater cause mold problems in AC systems?

Clearwater's year-round humidity creates ideal conditions for mold and biological growth inside air handlers, evaporator coils, and drain pans. Left unchecked, this circulates through your home's air and can cause health issues for residents. Air Bros inspects for mold and biological buildup on every maintenance visit and recommends UV light air purifiers for homes that have had recurring issues.

Is it worth replacing my AC system before hurricane season in Clearwater?

If your system is more than ten years old or has needed repeated repairs, replacing it before hurricane season is worth serious consideration. A storm doesn't just risk physical damage to your outdoor unit — the power surges and outages that follow can push an already-stressed system over the edge. Air Bros can assess your current system and give you an honest recommendation on whether repair or replacement makes more sense heading into June.

Recent Jobs and Reviews in Clearwater, FL

Clearwater, FL at a glance

Air Bros Air Conditioning & Electrical has completed 25 jobs in Clearwater, FL between March 2026 and May 2026.

The most recent job was on May 7, 2026.

Air Bros Air Conditioning & Electrical has completed 176 jobs in Clearwater, FL in the last 12 months. The first job there was in February 2025.

Job Locations and Reviews

Client state system is not keeping up with temperature. Found a severely clogged drain line and a trip to float safety switch. Also found a weak capacitor. Replaced the capacitor and performed a drain cleaning and treatment. Client signed up for maintenance plan, and I performed the first Maitenence. With an 18° temperature split good amp draws and clean coils. Cleaned the condenser coils.
Client state system is not keeping up with temperature. Found a severely clogged drain line and a trip to float safety switch. Also found a weak capacitor. Replaced the capacitor and performed a drain cleaning and treatment. Client signed up for maintenance plan, and I performed the first Maitenence. With an 18° temperature split good amp draws and clean coils. Cleaned the condenser coils.
Michael A.
Michael A. Checked in
Client state system is not keeping up with temperature. Found a severely clogged drain line and a trip to float safety switch. Also found a weak capacitor. Replaced the capacitor and performed a drain cleaning and treatment. Client signed up for maintenance plan, and I performed the first Maitenence. With an 18° temperature split good amp draws and clean coils. Cleaned the condenser coils.
Clearwater, FL 33764
Michael A.
Michael A. Checked in
Client states thermostat of losing power. Upon my inspection found the condensate pump and drain line completely clogged up. Checked temperature split is 20°. Performed a drain cleaning and treatment on the drain line, primary drain pan, and condensate pump. System is now cooling. Recommended a maintenance plan, but Client would like to pass at this time. Client states that evaporator coil was just replaced recently due to a refrigerant leak. Upon arrival, I noticed that the filter door to the unit was off and on the floor as well as there were no filters in any of the ceiling return grills. Highly recommend recommended getting new filters install installed as soon as possible.
Clearwater, FL 33761
Upon my inspection, found the secondary safety switch in the emergency pan was tripped with water. System does not have a primary safety float switch. Performed a drain cleaning on system. Added a primary safety float switch. Checked pressures and found system slightly low on refrigerant. Added 1 pound of refrigerant. As part of first Maintenence, cleaned condenser coils. System was cooling with a 16° temperature split. It is now cooling with a 18° temperature split. Tested drain line with 1 gallon of water. System is cooling and drain draining as best as it can at this time.

Tested capacitor is within tolerance limits. Checked amp draw on compressor. Checked amp draw on condenser fan motor and found the fan motor is over amping.
Upon my inspection, found the secondary safety switch in the emergency pan was tripped with water. System does not have a primary safety float switch. Performed a drain cleaning on system. Added a primary safety float switch. Checked pressures and found system slightly low on refrigerant. Added 1 pound of refrigerant. As part of first Maintenence, cleaned condenser coils. System was cooling with a 16° temperature split. It is now cooling with a 18° temperature split. Tested drain line with 1 gallon of water. System is cooling and drain draining as best as it can at this time.

Tested capacitor is within tolerance limits. Checked amp draw on compressor. Checked amp draw on condenser fan motor and found the fan motor is over amping.
Michael A.
Michael A. Checked in
Upon my inspection, found the secondary safety switch in the emergency pan was tripped with water. System does not have a primary safety float switch. Performed a drain cleaning on system. Added a primary safety float switch. Checked pressures and found system slightly low on refrigerant. Added 1 pound of refrigerant. As part of first Maintenence, cleaned condenser coils. System was cooling with a 16° temperature split. It is now cooling with a 18° temperature split. Tested drain line with 1 gallon of water. System is cooling and drain draining as best as it can at this time. Tested capacitor is within tolerance limits. Checked amp draw on compressor. Checked amp draw on condenser fan motor and found the fan motor is over amping.
Clearwater, FL 33756
Justin G.
Justin G. Checked in
On arrival found all unit not cooling due to low on refrigerant. Added back to factory specs. Unit is cooling. No error codes or electrical issues at this time. Made client aware that if issue happens again then a leak search will be needed to be done to locate leak. Unit cooling.
Clearwater, FL 33755
On arrival found unit not cooling due to weak capacitor. Replaced part. Start and test. Cleaned in place evap coil. Cleared drain. Unit cooling at his time.
On arrival found unit not cooling due to weak capacitor. Replaced part. Start and test. Cleaned in place evap coil. Cleared drain. Unit cooling at his time.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to weak capacitor. Replaced part. Start and test. Cleaned in place evap coil. Cleared drain. Unit cooling at his time.
Clearwater, FL 33761
Install Single 9k BTU Head 
Remote/App Operated 
Install Wall Mounting Bracket 
Hurricane Tie Down Straps
Vibration Pads
New Refrigerant Lines
New Communication Wire
Install Hard Pipe PVC Drain
Install Exterior Line Covers
Install Single 9k btu Outdoor Condenser 
Seal Penetration Points 
Pressure Test Systems 
Vacuum Systems 
Charge Systems 
UV Rated Outdoor Insulation 
Refrigerant Locking Caps
Electrical to Panel/Breaker
Outdoor Surge Protection 
New Outdoor Electrical Whip
New Outdoor Electrical Disconnect 
Permitting 
10 Year Parts Warranty 
3 Year Labor Warranty
Install Single 9k BTU Head 
Remote/App Operated 
Install Wall Mounting Bracket 
Hurricane Tie Down Straps
Vibration Pads
New Refrigerant Lines
New Communication Wire
Install Hard Pipe PVC Drain
Install Exterior Line Covers
Install Single 9k btu Outdoor Condenser 
Seal Penetration Points 
Pressure Test Systems 
Vacuum Systems 
Charge Systems 
UV Rated Outdoor Insulation 
Refrigerant Locking Caps
Electrical to Panel/Breaker
Outdoor Surge Protection 
New Outdoor Electrical Whip
New Outdoor Electrical Disconnect 
Permitting 
10 Year Parts Warranty 
3 Year Labor Warranty
Kyle K.
Kyle K. Checked in
Install Single 9k BTU Head Remote/App Operated Install Wall Mounting Bracket Hurricane Tie Down Straps Vibration Pads New Refrigerant Lines New Communication Wire Install Hard Pipe PVC Drain Install Exterior Line Covers Install Single 9k btu Outdoor Condenser Seal Penetration Points Pressure Test Systems Vacuum Systems Charge Systems UV Rated Outdoor Insulation Refrigerant Locking Caps Electrical to Panel/Breaker Outdoor Surge Protection New Outdoor Electrical Whip New Outdoor Electrical Disconnect Permitting 10 Year Parts Warranty 3 Year Labor Warranty
Clearwater, FL 33765
Clearwater, FL - Installation of Anti Microbial duct work. 
New boots and Grills. 
4 cut in returns
New return and supply plenum. 
All strapped up and sealed to code.
100% satusfaction 
Financing available
Martin W.
Martin W. Checked in
Installation of Anti Microbial duct work. New boots and Grills. 4 cut in returns New return and supply plenum. All strapped up and sealed to code. 100% satusfaction Financing available
Clearwater, FL 33764
Scope of work:
- Remove blower housing assembly. 
- Disconnect fan motor from housing
- Clean and sanitize blower assembly. 
- Re install and test

Recommending UV system to prevent this from happening again
Scope of work:
- Remove blower housing assembly. 
- Disconnect fan motor from housing
- Clean and sanitize blower assembly. 
- Re install and test

Recommending UV system to prevent this from happening again
Michael A.
Michael A. Checked in
Scope of work: - Remove blower housing assembly. - Disconnect fan motor from housing - Clean and sanitize blower assembly. - Re install and test Recommending UV system to prevent this from happening again
Clearwater, FL 33764
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Could not access the end of the drain line due to brush and plants being in the way. Cleaned condenser coils. Evaporator coils are clean but very damaged. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Contactar is chattering and at the end of its life span, we recommend replacing. Found low voltage wires exposed to the elements and we recommend making new connections while also sealing the wire in the condenser service panel. Made sure all connections are tight. System is cooling with an 18° temperature split at this time.

Blower wheel is very impacted with debris and growth. Recommending cleaning
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Could not access the end of the drain line due to brush and plants being in the way. Cleaned condenser coils. Evaporator coils are clean but very damaged. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Contactar is chattering and at the end of its life span, we recommend replacing. Found low voltage wires exposed to the elements and we recommend making new connections while also sealing the wire in the condenser service panel. Made sure all connections are tight. System is cooling with an 18° temperature split at this time.

Blower wheel is very impacted with debris and growth. Recommending cleaning
Michael A.
Michael A. Checked in
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Could not access the end of the drain line due to brush and plants being in the way. Cleaned condenser coils. Evaporator coils are clean but very damaged. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Contactar is chattering and at the end of its life span, we recommend replacing. Found low voltage wires exposed to the elements and we recommend making new connections while also sealing the wire in the condenser service panel. Made sure all connections are tight. System is cooling with an 18° temperature split at this time. Blower wheel is very impacted with debris and growth. Recommending cleaning
Clearwater, FL 33760
Upon my insection, client had another company performing is on the system for roughly 2 years. On their last visit, they recommended replacing the disconnect breaker at the unit, performing an evaporator coil cleaning, performing a blower assembly cleaning, installing a UV light, and adding refrigerant.

Upon my inspection, found disconnect not grounded properly and reconnected ground wire. Disconnect is in working condition. 
Unit has a 20° temperature split. Evaporator coils are slightly impacted with debris and the blower wheel assembly is slightly impacted with debris and bacterial growth. We recommend an evaporator coil cleaning, Blower assembly removal and cleaning, as well as a UV air Purifier inside the system to prevent the growth from returning. 

Amp draws are good, capacitor is within factory range, contactar is in good shape. 

Sending quotes for cleanings and Maitenence service agreement

Waived $95 per office request with repair
Upon my insection, client had another company performing is on the system for roughly 2 years. On their last visit, they recommended replacing the disconnect breaker at the unit, performing an evaporator coil cleaning, performing a blower assembly cleaning, installing a UV light, and adding refrigerant.

Upon my inspection, found disconnect not grounded properly and reconnected ground wire. Disconnect is in working condition. 
Unit has a 20° temperature split. Evaporator coils are slightly impacted with debris and the blower wheel assembly is slightly impacted with debris and bacterial growth. We recommend an evaporator coil cleaning, Blower assembly removal and cleaning, as well as a UV air Purifier inside the system to prevent the growth from returning. 

Amp draws are good, capacitor is within factory range, contactar is in good shape. 

Sending quotes for cleanings and Maitenence service agreement

Waived $95 per office request with repair
Michael A.
Michael A. Checked in
Upon my insection, client had another company performing is on the system for roughly 2 years. On their last visit, they recommended replacing the disconnect breaker at the unit, performing an evaporator coil cleaning, performing a blower assembly cleaning, installing a UV light, and adding refrigerant. Upon my inspection, found disconnect not grounded properly and reconnected ground wire. Disconnect is in working condition. Unit has a 20° temperature split. Evaporator coils are slightly impacted with debris and the blower wheel assembly is slightly impacted with debris and bacterial growth. We recommend an evaporator coil cleaning, Blower assembly removal and cleaning, as well as a UV air Purifier inside the system to prevent the growth from returning. Amp draws are good, capacitor is within factory range, contactar is in good shape. Sending quotes for cleanings and Maitenence service agreement Waived $95 per office request with repair
Clearwater, FL 33765
Ricky O.
Ricky O. Checked in
Found unit not cooling due to bad float switch not allowing system to come on. I replaced float switch and verified operation. Client just wants system running as they are moving tomorrow. System is cooling
Clearwater, FL 33763
Clearwater, FL - Installed uv air purification inside air handler #2.
Michael A.
Michael A. Checked in
Installed uv air purification inside air handler #2.
Clearwater, FL 33761
Ruud 3 ton heat pump
15 seer
10 year parts warranty
3 year labor warranty 
*Green cash price*
-Hurricane pad 
-Hurricane tiedowns
-UV rated armorflex
-Screw line cover back to home and silicone gaps
-New hang kit
-Drain pan
-Safeties
-Flush drain
-Keep existing filter system
-Seal to existing plenums 
-100% satisfaction guarantee
Ruud 3 ton heat pump
15 seer
10 year parts warranty
3 year labor warranty 
*Green cash price*
-Hurricane pad 
-Hurricane tiedowns
-UV rated armorflex
-Screw line cover back to home and silicone gaps
-New hang kit
-Drain pan
-Safeties
-Flush drain
-Keep existing filter system
-Seal to existing plenums 
-100% satisfaction guarantee
Martin W.
Martin W. Checked in
Ruud 3 ton heat pump 15 seer 10 year parts warranty 3 year labor warranty *Green cash price* -Hurricane pad -Hurricane tiedowns -UV rated armorflex -Screw line cover back to home and silicone gaps -New hang kit -Drain pan -Safeties -Flush drain -Keep existing filter system -Seal to existing plenums -100% satisfaction guarantee
Clearwater, FL 33755
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.

Condenser coils were very impacted with debris.  Deep cleaned as part of the Maitenence for this time only. If coils get this bad next time we will have to charge extra for cleaning. 

Quote sent over for Maitenence plan.
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.

Condenser coils were very impacted with debris.  Deep cleaned as part of the Maitenence for this time only. If coils get this bad next time we will have to charge extra for cleaning. 

Quote sent over for Maitenence plan.
Michael A.
Michael A. Checked in
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. Condenser coils were very impacted with debris. Deep cleaned as part of the Maitenence for this time only. If coils get this bad next time we will have to charge extra for cleaning. Quote sent over for Maitenence plan.
Clearwater, FL 33760
Found system freezing up due to severely clogged and impacted evaporator coils. System may also be low on refrigerant but we cannot accurately determine without proper air flow. Found lizard burnt on contactar and capacitor near its max tolerance limit. 
System cannot cool properly at this time. Client would like a system replacement estimate. Quote has been sent over.
Found system freezing up due to severely clogged and impacted evaporator coils. System may also be low on refrigerant but we cannot accurately determine without proper air flow. Found lizard burnt on contactar and capacitor near its max tolerance limit. 
System cannot cool properly at this time. Client would like a system replacement estimate. Quote has been sent over.
Michael A.
Michael A. Checked in
Found system freezing up due to severely clogged and impacted evaporator coils. System may also be low on refrigerant but we cannot accurately determine without proper air flow. Found lizard burnt on contactar and capacitor near its max tolerance limit. System cannot cool properly at this time. Client would like a system replacement estimate. Quote has been sent over.
Clearwater, FL 33756
I checked entire system and found no issues. All previous work done looks good. Cap and wiring good. Td 19. Explained to client not to reset breakers if this happens again just call us immediately and we will come out with no service fee
I checked entire system and found no issues. All previous work done looks good. Cap and wiring good. Td 19. Explained to client not to reset breakers if this happens again just call us immediately and we will come out with no service fee
Ricky O.
Ricky O. Checked in
I checked entire system and found no issues. All previous work done looks good. Cap and wiring good. Td 19. Explained to client not to reset breakers if this happens again just call us immediately and we will come out with no service fee
Clearwater, FL 33760
Upon my inspection, found severely clogged drain that was tripping the safety float switch. Also found evaporator coils are severely clogged, condenser coils dirty, and bare wires at the condenser disconnect causing the breaker to trip. 
Performed drain cleaning, removed faulty wires from disconnect, cleaned condenser coils, and performed Maitenence on system for first membership Maitenence. 
Capacitor is within factory range. Compressor amps are good. Fan motor amps were over its max rating due to dirty condenser coils. 

Client is aware of the severity of the evaporator coils and will schedule as soon as he is ready. 
System is cooling at this time with a 19° temp split. 

When we return to clean evaporator coils, we will re route the lineset connections and pvc connection to allow for filters to be installed directly underneath the coils.
Upon my inspection, found severely clogged drain that was tripping the safety float switch. Also found evaporator coils are severely clogged, condenser coils dirty, and bare wires at the condenser disconnect causing the breaker to trip. 
Performed drain cleaning, removed faulty wires from disconnect, cleaned condenser coils, and performed Maitenence on system for first membership Maitenence. 
Capacitor is within factory range. Compressor amps are good. Fan motor amps were over its max rating due to dirty condenser coils. 

Client is aware of the severity of the evaporator coils and will schedule as soon as he is ready. 
System is cooling at this time with a 19° temp split. 

When we return to clean evaporator coils, we will re route the lineset connections and pvc connection to allow for filters to be installed directly underneath the coils.
Michael A.
Michael A. Checked in
Upon my inspection, found severely clogged drain that was tripping the safety float switch. Also found evaporator coils are severely clogged, condenser coils dirty, and bare wires at the condenser disconnect causing the breaker to trip. Performed drain cleaning, removed faulty wires from disconnect, cleaned condenser coils, and performed Maitenence on system for first membership Maitenence. Capacitor is within factory range. Compressor amps are good. Fan motor amps were over its max rating due to dirty condenser coils. Client is aware of the severity of the evaporator coils and will schedule as soon as he is ready. System is cooling at this time with a 19° temp split. When we return to clean evaporator coils, we will re route the lineset connections and pvc connection to allow for filters to be installed directly underneath the coils.
Clearwater, FL 33756
Performed Maitenence on system. System is working as best as it can given its age and condition. High compressor amps on start up. 
Client would like to invest in new system and duct work but needs to figure out finances first. 
System is cooling at this time.
Performed Maitenence on system. System is working as best as it can given its age and condition. High compressor amps on start up. 
Client would like to invest in new system and duct work but needs to figure out finances first. 
System is cooling at this time.
Michael A.
Michael A. Checked in
Performed Maitenence on system. System is working as best as it can given its age and condition. High compressor amps on start up. Client would like to invest in new system and duct work but needs to figure out finances first. System is cooling at this time.
Clearwater, FL 33764
Clearwater, FL - Install customer supplied ceiling fan and run a new line from a receptacle
Griffin K.
Griffin K. Checked in
Install customer supplied ceiling fan and run a new line from a receptacle
Clearwater, FL 33765
Upon my inspection, found indoor 3amp fuse blown. Found short at condenser contactar. Replaced contactar and fuse. Verified system is cooling at this time. System has a 16° temperature split.
Upon my inspection, found indoor 3amp fuse blown. Found short at condenser contactar. Replaced contactar and fuse. Verified system is cooling at this time. System has a 16° temperature split.
Michael A.
Michael A. Checked in
Upon my inspection, found indoor 3amp fuse blown. Found short at condenser contactar. Replaced contactar and fuse. Verified system is cooling at this time. System has a 16° temperature split.
Clearwater, FL 33763
Installed new warranty evap coil. Charged with new refrigerant. New drain connections off of unit. System is cooling with a 20° temperature split and target superheat. Found weak capacitor but client would not like to replace at this time. 
Performed full Maitenence on system. Checked amp draws, inspected wiring, checked capacitor, cleaned condenser coils, cleaned and treated drain line.
Installed new warranty evap coil. Charged with new refrigerant. New drain connections off of unit. System is cooling with a 20° temperature split and target superheat. Found weak capacitor but client would not like to replace at this time. 
Performed full Maitenence on system. Checked amp draws, inspected wiring, checked capacitor, cleaned condenser coils, cleaned and treated drain line.
Michael A.
Michael A. Checked in
Installed new warranty evap coil. Charged with new refrigerant. New drain connections off of unit. System is cooling with a 20° temperature split and target superheat. Found weak capacitor but client would not like to replace at this time. Performed full Maitenence on system. Checked amp draws, inspected wiring, checked capacitor, cleaned condenser coils, cleaned and treated drain line.
Clearwater, FL 33756
Performed leak search and found refrigerant leak in coil. Applied leak search fee to repair. 
Will return Friday to install new evaporator coil and refrigerant.
Performed leak search and found refrigerant leak in coil. Applied leak search fee to repair. 
Will return Friday to install new evaporator coil and refrigerant.
Michael A.
Michael A. Checked in
Performed leak search and found refrigerant leak in coil. Applied leak search fee to repair. Will return Friday to install new evaporator coil and refrigerant.
Clearwater, FL 33756
Scope of work:
- Remove and replace variable speed blower motor
- Remove and replace condenser start/run capacitor. 
*No guarantee on system running properly as compressor could have sustained irreversible damage during operation with a faulty blower motor and capacitor.*

System is cooling properly at this time. Good amp draws on fan motors and compressor. 

Cleaned and sanitized blower wheel complimentary
Scope of work:
- Remove and replace variable speed blower motor
- Remove and replace condenser start/run capacitor. 
*No guarantee on system running properly as compressor could have sustained irreversible damage during operation with a faulty blower motor and capacitor.*

System is cooling properly at this time. Good amp draws on fan motors and compressor. 

Cleaned and sanitized blower wheel complimentary
Michael A.
Michael A. Checked in
Scope of work: - Remove and replace variable speed blower motor - Remove and replace condenser start/run capacitor. *No guarantee on system running properly as compressor could have sustained irreversible damage during operation with a faulty blower motor and capacitor.* System is cooling properly at this time. Good amp draws on fan motors and compressor. Cleaned and sanitized blower wheel complimentary
Clearwater, FL 33761

Diagnosed bad variable speed blower motor and bad condenser capacitor. Quote sent and approved for replacement. System is 11 years old and client would like to have his own guys replace system and would like us to repair at this time. 
Waiving $95 off sold quote for repair. 

No guarantee on system running prior to repair due to system running with a faulty blower motor and bad capacitor.

Diagnosed bad variable speed blower motor and bad condenser capacitor. Quote sent and approved for replacement. System is 11 years old and client would like to have his own guys replace system and would like us to repair at this time. 
Waiving $95 off sold quote for repair. 

No guarantee on system running prior to repair due to system running with a faulty blower motor and bad capacitor.
Michael A.
Michael A. Checked in
Diagnosed bad variable speed blower motor and bad condenser capacitor. Quote sent and approved for replacement. System is 11 years old and client would like to have his own guys replace system and would like us to repair at this time. Waiving $95 off sold quote for repair. No guarantee on system running prior to repair due to system running with a faulty blower motor and bad capacitor.
Clearwater, FL 33761
Performed Maitenence on all 5 systems
Left side of building
System #1: trane
- weak blower motor capacitor 18 out of 20 6% max tolerance
- Very dirty and impacted fan blower wheel
- Very dirty and restrictive evaporator coils
Sending quote for new system replacement. 
Client has on concerns with air flow on this system and wanted to move duct work. Recommended replacing system first as the system is restricted of air flow due to impacted coils and blower wheel. 

System #2 ruud
- Very dirty and impacted fan blower wheel

Right side of building

System #1 ruud
- No issues or inefficiencies
System #2 ruud
- No issues or inefficiencies
System #3 trane
- Very dirty and impacted fan blower wheel
- Very dirty and restrictive evaporator coils
Performed Maitenence on all 5 systems
Left side of building
System #1: trane
- weak blower motor capacitor 18 out of 20 6% max tolerance
- Very dirty and impacted fan blower wheel
- Very dirty and restrictive evaporator coils
Sending quote for new system replacement. 
Client has on concerns with air flow on this system and wanted to move duct work. Recommended replacing system first as the system is restricted of air flow due to impacted coils and blower wheel. 

System #2 ruud
- Very dirty and impacted fan blower wheel

Right side of building

System #1 ruud
- No issues or inefficiencies
System #2 ruud
- No issues or inefficiencies
System #3 trane
- Very dirty and impacted fan blower wheel
- Very dirty and restrictive evaporator coils
Michael A.
Michael A. Checked in
Performed Maitenence on all 5 systems Left side of building System #1: trane - weak blower motor capacitor 18 out of 20 6% max tolerance - Very dirty and impacted fan blower wheel - Very dirty and restrictive evaporator coils Sending quote for new system replacement. Client has on concerns with air flow on this system and wanted to move duct work. Recommended replacing system first as the system is restricted of air flow due to impacted coils and blower wheel. System #2 ruud - Very dirty and impacted fan blower wheel Right side of building System #1 ruud - No issues or inefficiencies System #2 ruud - No issues or inefficiencies System #3 trane - Very dirty and impacted fan blower wheel - Very dirty and restrictive evaporator coils
Clearwater, FL 33762

Contact the Bros You Know Today!

Gravity Forms Pagination Must be Steps