Instant Quote Shop Filters Call Air Bros Book Service

St. Petersburg, FL

air-bros-team-with-truck

Your St. Petersburg, FL HVAC Experts

Air Bros Air Conditioning & Heating is proud to serve the vibrant community of St. Petersburg, FL. We understand the unique challenges that St. Petersburg homeowners and businesses face when it comes to maintaining comfortable indoor temperatures year-round. Our team of experienced and certified technicians is dedicated to providing top-quality HVAC services tailored to the specific needs of our St. Petersburg customers.

Call us at 727-217-6148 or contact us online today for all of your HVAC, indoor air quality and electrical needs.

Comprehensive HVAC Services in St. Petersburg

We offer a full range of heating and cooling services to keep your St. Petersburg, FL, home comfortable year-round:

  • Air Conditioning: From AC repair and AC installation to routine maintenance, we ensure your cooling system keeps you comfortable during those hot Florida summers. We offer same-day service for AC emergencies, so you never have to suffer in the heat.
  • Heating: Stay warm and cozy in the winter with our comprehensive heating services. We repair and install all types of heating systems, including furnaces and heat pumps, and offer preventative maintenance to keep your system running efficiently.
  • Indoor Air Quality: Improve your indoor air quality with our dehumidifier and UV light installation services. We'll help you control excess humidity and eliminate airborne contaminants, creating a healthier home environment.
  • Ductwork: Ensure optimal airflow and energy efficiency with our ductwork repair and installation services. We can address leaks and damage, and design a system that's perfect for your home.
  • Pool Heater Services: Extend your swim season with our pool heater installation and repair services.
  • Electrical Services: From outlet and switch replacements to ceiling fan installations to whole-house surge protector installations, we have the experts to handle your electrical service needs.

Our experienced technicians are skilled in all aspects of HVAC service and are dedicated to providing top-quality workmanship and customer care.

Why Choose Air Bros?

  • Local Expertise: We understand the unique climate challenges of St. Petersburg.
  • Fast and Reliable Service: We offer same-day service for AC emergencies and prioritize prompt service for all your HVAC needs.
  • Experienced Technicians: Our team is highly trained and experienced in all aspects of HVAC service.
  • Upfront Pricing: We provide transparent pricing with no hidden costs.
  • Customer Satisfaction Guaranteed: Your comfort and satisfaction are our top priorities.

Contact Air Bros Today!

Whether you need emergency AC repair, a new heating system installation, or any other HVAC service, Air Bros is here to help. Contact us today for a free consultation or to schedule a service appointment. We're proud to be your trusted HVAC partner in St. Petersburg!

Call us at 727-217-6148 or contact us online today!

Our St. Petersburg Location

Address: 1579 Delaware Ave NESt. Petersburg, FL 33703

Phone: 727-217-6148

Count on perfect service; Trust the bros you know!

Recent Jobs and Reviews in St. Petersburg, FL

Job Locations and Reviews

On arrival found unit not cooling properly due to blower motor shorted and spinning backwards. Replaced motor. Start and test. Pressures good. Temp split good. Cleared drain. Unit cooling properly at this time.
On arrival found unit not cooling properly due to blower motor shorted and spinning backwards. Replaced motor. Start and test. Pressures good. Temp split good. Cleared drain. Unit cooling properly at this time.
Justin G.
Justin G. Checked in
On arrival found unit not cooling properly due to blower motor shorted and spinning backwards. Replaced motor. Start and test. Pressures good. Temp split good. Cleared drain. Unit cooling properly at this time.
St. Petersburg, FL 33710
Reason for call:
No cool 

Equipment:
2014 trane 4 ton 
Vertical in garage 
Condenser located left of home 

Summary:
On arrival found condenser fan motor off. Found a failed capacitor. Informed homeowner brother in law and replaced both the capacitor and the contactor today. Restored operation to the condenser fan. Unit was up and running and cooling. Then unit shut off on low pressure due to eev closing and not reacting properly. The eev and eev control board will have to be replaced to restore proper operation to the equipment. 

Leaving quote for new system today. 
Leaving quote for repair tomorrow.
Reason for call:
No cool 

Equipment:
2014 trane 4 ton 
Vertical in garage 
Condenser located left of home 

Summary:
On arrival found condenser fan motor off. Found a failed capacitor. Informed homeowner brother in law and replaced both the capacitor and the contactor today. Restored operation to the condenser fan. Unit was up and running and cooling. Then unit shut off on low pressure due to eev closing and not reacting properly. The eev and eev control board will have to be replaced to restore proper operation to the equipment. 

Leaving quote for new system today. 
Leaving quote for repair tomorrow.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Equipment: 2014 trane 4 ton Vertical in garage Condenser located left of home Summary: On arrival found condenser fan motor off. Found a failed capacitor. Informed homeowner brother in law and replaced both the capacitor and the contactor today. Restored operation to the condenser fan. Unit was up and running and cooling. Then unit shut off on low pressure due to eev closing and not reacting properly. The eev and eev control board will have to be replaced to restore proper operation to the equipment. Leaving quote for new system today. Leaving quote for repair tomorrow.
St. Petersburg, FL 33702
On arrival found unit running and cooling. Inspected unit for possible causes. Found unit float to have water in it. Condenser capacitor is reading extremely weak. Found thermostat wire for outdoor condenser to have short in it. All issues should be addressed. Client opted to only replace capacitor at this time and will clear drain themselves. Condenser is also unlevel and filter dryer extremely corroded and should be replaced. Will submit estimate for all other issues. Unit is cooling at this time.
On arrival found unit running and cooling. Inspected unit for possible causes. Found unit float to have water in it. Condenser capacitor is reading extremely weak. Found thermostat wire for outdoor condenser to have short in it. All issues should be addressed. Client opted to only replace capacitor at this time and will clear drain themselves. Condenser is also unlevel and filter dryer extremely corroded and should be replaced. Will submit estimate for all other issues. Unit is cooling at this time.
Justin G.
Justin G. Checked in
On arrival found unit running and cooling. Inspected unit for possible causes. Found unit float to have water in it. Condenser capacitor is reading extremely weak. Found thermostat wire for outdoor condenser to have short in it. All issues should be addressed. Client opted to only replace capacitor at this time and will clear drain themselves. Condenser is also unlevel and filter dryer extremely corroded and should be replaced. Will submit estimate for all other issues. Unit is cooling at this time.
St. Petersburg, FL 33703
Reason for call:
No cool 

Equipment:
2023 trane 3.5 ton heat pump 
Vertical on third floor closet 
Condenser is located on roof 

Summary:
Completed diagnosis to find failed dual capacitor. Informed homeowner we replace caps and contactor together because they work in tandem and that yields the best results. He agreed and replaced dual capacitor and contactor today to restore operation to equipment. 20 degree split.
Reason for call:
No cool 

Equipment:
2023 trane 3.5 ton heat pump 
Vertical on third floor closet 
Condenser is located on roof 

Summary:
Completed diagnosis to find failed dual capacitor. Informed homeowner we replace caps and contactor together because they work in tandem and that yields the best results. He agreed and replaced dual capacitor and contactor today to restore operation to equipment. 20 degree split.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Equipment: 2023 trane 3.5 ton heat pump Vertical on third floor closet Condenser is located on roof Summary: Completed diagnosis to find failed dual capacitor. Informed homeowner we replace caps and contactor together because they work in tandem and that yields the best results. He agreed and replaced dual capacitor and contactor today to restore operation to equipment. 20 degree split.
St. Petersburg, FL 33712
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to clogged drain. Client declined repairs at this time and feels confident that o make repairs themselves. Found media filter extremely impacted and recommended to replace asap. Explained to client service fee will be charged again if clogged drain is unable to be cleared by homeowner. Found evaporator and condenser coils impacted by dust and debris. Recommend heavy chemical cleanings to help prevent future breakdowns.
St. Petersburg, FL 33704
Reason for call:
No cool 

Equipment:
2015 Goodman 2 ton straight cool 
Condenser out front of hiking under scaffolding 
Vertical in closet 

Summary:
Found condenser breaker tripped. Found compressor shorted to ground. Compressor has failed. Spoke with homeowner and he agreed that system replacement is his best option. Spoke with him about quote he is looking to get a couple other opinions and follow up with us.
Reason for call:
No cool 

Equipment:
2015 Goodman 2 ton straight cool 
Condenser out front of hiking under scaffolding 
Vertical in closet 

Summary:
Found condenser breaker tripped. Found compressor shorted to ground. Compressor has failed. Spoke with homeowner and he agreed that system replacement is his best option. Spoke with him about quote he is looking to get a couple other opinions and follow up with us.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Equipment: 2015 Goodman 2 ton straight cool Condenser out front of hiking under scaffolding Vertical in closet Summary: Found condenser breaker tripped. Found compressor shorted to ground. Compressor has failed. Spoke with homeowner and he agreed that system replacement is his best option. Spoke with him about quote he is looking to get a couple other opinions and follow up with us.
St. Petersburg, FL 33702
On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Vacuumed and blew through line. Added chemical to help prevent growth in drain. Temp split 17*. Electrical checked good. Drain was hard to clear properly. Recommend to add condensate pump to prevent future drainage issues. Unit cooling.
On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Vacuumed and blew through line. Added chemical to help prevent growth in drain. Temp split 17*. Electrical checked good. Drain was hard to clear properly. Recommend to add condensate pump to prevent future drainage issues. Unit cooling.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Vacuumed and blew through line. Added chemical to help prevent growth in drain. Temp split 17*. Electrical checked good. Drain was hard to clear properly. Recommend to add condensate pump to prevent future drainage issues. Unit cooling.
St. Petersburg, FL 33705
Replaced failed contractor 

Spliced new wiring connections 

Spliced whip to extend for wiring 

Checked amp draws 

Verified system operations
Replaced failed contractor 

Spliced new wiring connections 

Spliced whip to extend for wiring 

Checked amp draws 

Verified system operations
Nathan A.
Nathan A. Checked in
Replaced failed contractor Spliced new wiring connections Spliced whip to extend for wiring Checked amp draws Verified system operations
St. Petersburg, FL 33702
RUUD Equipment (INVERTER)
Install New Air Handler 
Install Coffin Box (3ft)
Install 4” Media Filter Rack 
Install Air Handler UV System
Install New Outdoor Condenser 
New Filter Drier 
Install Thermostat (Auto Changeover)
Thermostat Wire Included 
Primary Float Safety Switch
Outdoor Surge Protection 
UV Rated Outdoor Insulation 
Refrigerant Locking Caps
Flush Existing Refrigerant Lines
Flush Drain Line
4” Hurricane Pad
18” Hurricane Stand 
Vibration Pads
Hurricane Tie Down Straps
Vacuum System 
Seal Supply/Return Plenums 
Remove Current Equipment
Replace Breakers (As Needed)
Permitting 
10 Year Parts Warranty
3 Year Labor Warranty 
100% Satisfaction 

*Strap ducting at hallway access 
*Move outdoor condenser to be flush with side of home 
*Program unit to 3.5T
RUUD Equipment (INVERTER)
Install New Air Handler 
Install Coffin Box (3ft)
Install 4” Media Filter Rack 
Install Air Handler UV System
Install New Outdoor Condenser 
New Filter Drier 
Install Thermostat (Auto Changeover)
Thermostat Wire Included 
Primary Float Safety Switch
Outdoor Surge Protection 
UV Rated Outdoor Insulation 
Refrigerant Locking Caps
Flush Existing Refrigerant Lines
Flush Drain Line
4” Hurricane Pad
18” Hurricane Stand 
Vibration Pads
Hurricane Tie Down Straps
Vacuum System 
Seal Supply/Return Plenums 
Remove Current Equipment
Replace Breakers (As Needed)
Permitting 
10 Year Parts Warranty
3 Year Labor Warranty 
100% Satisfaction 

*Strap ducting at hallway access 
*Move outdoor condenser to be flush with side of home 
*Program unit to 3.5T
Justin G.
Justin G. Checked in
RUUD Equipment (INVERTER) Install New Air Handler Install Coffin Box (3ft) Install 4” Media Filter Rack Install Air Handler UV System Install New Outdoor Condenser New Filter Drier Install Thermostat (Auto Changeover) Thermostat Wire Included Primary Float Safety Switch Outdoor Surge Protection UV Rated Outdoor Insulation Refrigerant Locking Caps Flush Existing Refrigerant Lines Flush Drain Line 4” Hurricane Pad 18” Hurricane Stand Vibration Pads Hurricane Tie Down Straps Vacuum System Seal Supply/Return Plenums Remove Current Equipment Replace Breakers (As Needed) Permitting 10 Year Parts Warranty 3 Year Labor Warranty 100% Satisfaction *Strap ducting at hallway access *Move outdoor condenser to be flush with side of home *Program unit to 3.5T
St. Petersburg, FL 33713
Reason for call:
No pool upstairs unit

Equipment:
2017 nordyn 2 ton 
Vertical on second floor 
Condenser on right side of home 

Summary:
Completed diagnostic to find refrigerant pressure slightly low, clean, drain line and found oil residue inside evaporator pan and drain. Added 2 pounds of refrigerant to bring system back within manufacturing specification. Performed leak search to find evaporator coil leaking refrigerant. 

Solution:
Evaporated coil will have to be replaced. 
System is from 2017 and does not have parts warranty on it.
System replacement is an option. Homeowner is looking for a repair quote.
Reason for call:
No pool upstairs unit

Equipment:
2017 nordyn 2 ton 
Vertical on second floor 
Condenser on right side of home 

Summary:
Completed diagnostic to find refrigerant pressure slightly low, clean, drain line and found oil residue inside evaporator pan and drain. Added 2 pounds of refrigerant to bring system back within manufacturing specification. Performed leak search to find evaporator coil leaking refrigerant. 

Solution:
Evaporated coil will have to be replaced. 
System is from 2017 and does not have parts warranty on it.
System replacement is an option. Homeowner is looking for a repair quote.
Corbin C.
Corbin C. Checked in
Reason for call: No pool upstairs unit Equipment: 2017 nordyn 2 ton Vertical on second floor Condenser on right side of home Summary: Completed diagnostic to find refrigerant pressure slightly low, clean, drain line and found oil residue inside evaporator pan and drain. Added 2 pounds of refrigerant to bring system back within manufacturing specification. Performed leak search to find evaporator coil leaking refrigerant. Solution: Evaporated coil will have to be replaced. System is from 2017 and does not have parts warranty on it. System replacement is an option. Homeowner is looking for a repair quote.
St. Petersburg, FL 33711
Downstairs Unit Diagnosis 
-thermostat failed and not calling for outdoor unit 
-outdoor compressor wire heating up and melting wires 

Scope of work 
-replaced and wired/programmed thermostat 
-spliced new outdoor wiring 
-verified capacitor operations 

System is currently operating 

Compressor is starting to hum and overheating wiring. No guarantee on life span
Downstairs Unit Diagnosis 
-thermostat failed and not calling for outdoor unit 
-outdoor compressor wire heating up and melting wires 

Scope of work 
-replaced and wired/programmed thermostat 
-spliced new outdoor wiring 
-verified capacitor operations 

System is currently operating 

Compressor is starting to hum and overheating wiring. No guarantee on life span
Nathan A.
Nathan A. Checked in
Downstairs Unit Diagnosis -thermostat failed and not calling for outdoor unit -outdoor compressor wire heating up and melting wires Scope of work -replaced and wired/programmed thermostat -spliced new outdoor wiring -verified capacitor operations System is currently operating Compressor is starting to hum and overheating wiring. No guarantee on life span
St. Petersburg, FL 33705
Upon arrival, I began by checking the temperature differential between the supply and return air. The system was maintaining a 20°F temperature split, which is within a healthy operating range.

Next, I inspected the refrigerant cycle. Pressures and temperatures were operating within normal specifications, and there are currently no signs of refrigerant leaks or restrictions. The refrigerant system is functioning properly.

I then completed an electrical inspection. Both high-voltage and low-voltage components are operating correctly, and all electrical readings were within acceptable ranges.

During today’s visit, I performed a drain line treatment, condenser coil cleaning, and air handler inspection.

An additional recommendation is a blower wheel pull and cleaning. The blower wheel currently has dust accumulation on all blades, which can reduce airflow efficiency and place additional strain on the blower motor. Cleaning the blower wheel will help improve system performance and longe
Upon arrival, I began by checking the temperature differential between the supply and return air. The system was maintaining a 20°F temperature split, which is within a healthy operating range.

Next, I inspected the refrigerant cycle. Pressures and temperatures were operating within normal specifications, and there are currently no signs of refrigerant leaks or restrictions. The refrigerant system is functioning properly.

I then completed an electrical inspection. Both high-voltage and low-voltage components are operating correctly, and all electrical readings were within acceptable ranges.

During today’s visit, I performed a drain line treatment, condenser coil cleaning, and air handler inspection.

An additional recommendation is a blower wheel pull and cleaning. The blower wheel currently has dust accumulation on all blades, which can reduce airflow efficiency and place additional strain on the blower motor. Cleaning the blower wheel will help improve system performance and longe
ihsan m.
ihsan m. Checked in
Upon arrival, I began by checking the temperature differential between the supply and return air. The system was maintaining a 20°F temperature split, which is within a healthy operating range. Next, I inspected the refrigerant cycle. Pressures and temperatures were operating within normal specifications, and there are currently no signs of refrigerant leaks or restrictions. The refrigerant system is functioning properly. I then completed an electrical inspection. Both high-voltage and low-voltage components are operating correctly, and all electrical readings were within acceptable ranges. During today’s visit, I performed a drain line treatment, condenser coil cleaning, and air handler inspection. An additional recommendation is a blower wheel pull and cleaning. The blower wheel currently has dust accumulation on all blades, which can reduce airflow efficiency and place additional strain on the blower motor. Cleaning the blower wheel will help improve system performance and longe
St. Petersburg, FL 33702
Reason for call:
Tune up 

Equipment:
2018 trane 2.5 ton 
Vertical in closet
Condenser out back 

Summary:
Completed tune up to find unit operating outside of manufacture specifications. Found refrigerant pressure low. Found weak capacitor with burnt common wire, found burnt and pitted contactor. Flushed indoor and outdoor coils. Flushed drain and drain pan. Filters have been maintained properly. 

Solution:
Replace capacitor due to weak reading today 
Replace contactor due to burnt and pitted points 
Add 410 a to system 

Offered homeowner and her son a leak search they want to hold off on leak search and get tune up 6-10 months from now to reevaluate pressures.
Reason for call:
Tune up 

Equipment:
2018 trane 2.5 ton 
Vertical in closet
Condenser out back 

Summary:
Completed tune up to find unit operating outside of manufacture specifications. Found refrigerant pressure low. Found weak capacitor with burnt common wire, found burnt and pitted contactor. Flushed indoor and outdoor coils. Flushed drain and drain pan. Filters have been maintained properly. 

Solution:
Replace capacitor due to weak reading today 
Replace contactor due to burnt and pitted points 
Add 410 a to system 

Offered homeowner and her son a leak search they want to hold off on leak search and get tune up 6-10 months from now to reevaluate pressures.
Corbin C.
Corbin C. Checked in
Reason for call: Tune up Equipment: 2018 trane 2.5 ton Vertical in closet Condenser out back Summary: Completed tune up to find unit operating outside of manufacture specifications. Found refrigerant pressure low. Found weak capacitor with burnt common wire, found burnt and pitted contactor. Flushed indoor and outdoor coils. Flushed drain and drain pan. Filters have been maintained properly. Solution: Replace capacitor due to weak reading today Replace contactor due to burnt and pitted points Add 410 a to system Offered homeowner and her son a leak search they want to hold off on leak search and get tune up 6-10 months from now to reevaluate pressures.
St. Petersburg, FL 33703
Upon arrival, I began by checking the temperature differential between the supply and return air. The system was maintaining a 20°F temperature split, which is within a healthy operating range.

Next, I inspected the refrigerant cycle. Pressures and temperatures were operating within normal specifications, and there are currently no signs of refrigerant leaks or restrictions. The refrigerant system is functioning properly.

I then completed an electrical inspection. Both high-voltage and low-voltage components are operating correctly, and all electrical readings were within acceptable ranges.

The primary recommendation at this time is to replace the capacitor. The capacitor is not testing below its rated microfarad (µF) value but is showing signs of rust and deterioration. Replacing it proactively can help prevent future system interruptions and component failures.

During today’s visit, I performed a drain line treatment, condenser coil cleaning, and air handler inspection.

An addit
Upon arrival, I began by checking the temperature differential between the supply and return air. The system was maintaining a 20°F temperature split, which is within a healthy operating range.

Next, I inspected the refrigerant cycle. Pressures and temperatures were operating within normal specifications, and there are currently no signs of refrigerant leaks or restrictions. The refrigerant system is functioning properly.

I then completed an electrical inspection. Both high-voltage and low-voltage components are operating correctly, and all electrical readings were within acceptable ranges.

The primary recommendation at this time is to replace the capacitor. The capacitor is not testing below its rated microfarad (µF) value but is showing signs of rust and deterioration. Replacing it proactively can help prevent future system interruptions and component failures.

During today’s visit, I performed a drain line treatment, condenser coil cleaning, and air handler inspection.

An addit
ihsan m.
ihsan m. Checked in
Upon arrival, I began by checking the temperature differential between the supply and return air. The system was maintaining a 20°F temperature split, which is within a healthy operating range. Next, I inspected the refrigerant cycle. Pressures and temperatures were operating within normal specifications, and there are currently no signs of refrigerant leaks or restrictions. The refrigerant system is functioning properly. I then completed an electrical inspection. Both high-voltage and low-voltage components are operating correctly, and all electrical readings were within acceptable ranges. The primary recommendation at this time is to replace the capacitor. The capacitor is not testing below its rated microfarad (µF) value but is showing signs of rust and deterioration. Replacing it proactively can help prevent future system interruptions and component failures. During today’s visit, I performed a drain line treatment, condenser coil cleaning, and air handler inspection. An addit
St. Petersburg, FL 33703
On arrival found unit not cooling due to weak capacitor on condenser. Replaced part. Start and test. Found pressures to be below factory specs. Contactor is worn and has corrosion. Condenser coils impacted and compressor is surrounded by leaves. Recommend to fill unit to factory specs, replace worn contactor, clean condenser coils and remove all leaves and debris. Client declined recommendations at this time. Unit is cooling.
On arrival found unit not cooling due to weak capacitor on condenser. Replaced part. Start and test. Found pressures to be below factory specs. Contactor is worn and has corrosion. Condenser coils impacted and compressor is surrounded by leaves. Recommend to fill unit to factory specs, replace worn contactor, clean condenser coils and remove all leaves and debris. Client declined recommendations at this time. Unit is cooling.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to weak capacitor on condenser. Replaced part. Start and test. Found pressures to be below factory specs. Contactor is worn and has corrosion. Condenser coils impacted and compressor is surrounded by leaves. Recommend to fill unit to factory specs, replace worn contactor, clean condenser coils and remove all leaves and debris. Client declined recommendations at this time. Unit is cooling.
St. Petersburg, FL 33703
Client stated that inspector for selling the home pointed out a few issues. I was told the orange wire in the air handler closet needs to be addressed as it is not capped off and stored away so that it cannot be accessed easily, holes in the ceiling above the air handler need to be sealed off and the unit kept turning off a couple degrees before the desired temperature. 
Provided a quote for our electrician to come out and address the electrical issues and seal the ceiling holes for a total of $400 and client would like to have their own electrician come out. 

Found the system was shutting off due to low pressure cut off switch. System is low on refrigerant. Performed leak search and found only leak at the schrader core valve at the condenser. Repaired this leak and charged system with refrigerant to bring back to factory spec. 

System is now cooling with a 20° temperature split.
Client stated that inspector for selling the home pointed out a few issues. I was told the orange wire in the air handler closet needs to be addressed as it is not capped off and stored away so that it cannot be accessed easily, holes in the ceiling above the air handler need to be sealed off and the unit kept turning off a couple degrees before the desired temperature. 
Provided a quote for our electrician to come out and address the electrical issues and seal the ceiling holes for a total of $400 and client would like to have their own electrician come out. 

Found the system was shutting off due to low pressure cut off switch. System is low on refrigerant. Performed leak search and found only leak at the schrader core valve at the condenser. Repaired this leak and charged system with refrigerant to bring back to factory spec. 

System is now cooling with a 20° temperature split.
Michael A.
Michael A. Checked in
Client stated that inspector for selling the home pointed out a few issues. I was told the orange wire in the air handler closet needs to be addressed as it is not capped off and stored away so that it cannot be accessed easily, holes in the ceiling above the air handler need to be sealed off and the unit kept turning off a couple degrees before the desired temperature. Provided a quote for our electrician to come out and address the electrical issues and seal the ceiling holes for a total of $400 and client would like to have their own electrician come out. Found the system was shutting off due to low pressure cut off switch. System is low on refrigerant. Performed leak search and found only leak at the schrader core valve at the condenser. Repaired this leak and charged system with refrigerant to bring back to factory spec. System is now cooling with a 20° temperature split.
St. Petersburg, FL 33702
Replace evaporator coil under warranty. Recharge system.
Replace evaporator coil under warranty. Recharge system.
Corbin C.
Corbin C. Checked in
Replace evaporator coil under warranty. Recharge system.
St. Petersburg, FL 33701
Perform mini split blower removal and cleaning. Clean evaporator coils. Completely dismantled the unit to thoroughly clean and sanitize. 
Discount UV system bundle with cleaning -$100 from $750 for UV installation. 
Installed UV system with 5 year parts warranty.
Perform mini split blower removal and cleaning. Clean evaporator coils. Completely dismantled the unit to thoroughly clean and sanitize. 
Discount UV system bundle with cleaning -$100 from $750 for UV installation. 
Installed UV system with 5 year parts warranty.
Michael A.
Michael A. Checked in
Perform mini split blower removal and cleaning. Clean evaporator coils. Completely dismantled the unit to thoroughly clean and sanitize. Discount UV system bundle with cleaning -$100 from $750 for UV installation. Installed UV system with 5 year parts warranty.
St. Petersburg, FL 33703
Reason for call:
Member tune up 

Equipment:
2014 rheem 4 ton heat pump 
Vertical in closet 
Condenser on roof 

Summary:
Completed tune up to find equipment operating within manufacturing specifications. Confirmed pressure, temps, amp draws and cap readings. All though cap and contactor were operating I recommend replacing due to rusted terminals and age of starting components. Flushed drain. Flushed indoor and outdoor coils. Filters have been maintained properly. 

Solution:
Replace capacitor due to rusted top and terminals 
Replace contactor due to burnt contact points and rusted terminals
Reason for call:
Member tune up 

Equipment:
2014 rheem 4 ton heat pump 
Vertical in closet 
Condenser on roof 

Summary:
Completed tune up to find equipment operating within manufacturing specifications. Confirmed pressure, temps, amp draws and cap readings. All though cap and contactor were operating I recommend replacing due to rusted terminals and age of starting components. Flushed drain. Flushed indoor and outdoor coils. Filters have been maintained properly. 

Solution:
Replace capacitor due to rusted top and terminals 
Replace contactor due to burnt contact points and rusted terminals
Corbin C.
Corbin C. Checked in
Reason for call: Member tune up Equipment: 2014 rheem 4 ton heat pump Vertical in closet Condenser on roof Summary: Completed tune up to find equipment operating within manufacturing specifications. Confirmed pressure, temps, amp draws and cap readings. All though cap and contactor were operating I recommend replacing due to rusted terminals and age of starting components. Flushed drain. Flushed indoor and outdoor coils. Filters have been maintained properly. Solution: Replace capacitor due to rusted top and terminals Replace contactor due to burnt contact points and rusted terminals
St. Petersburg, FL 33715
Sean B.
Sean B. Checked in
Replacing boot and enlarging supply duct 5in
St. Petersburg, FL 33704
Replace condenser coils
Replace condenser coils
Justin G.
Justin G. Checked in
Replace condenser coils
St. Petersburg, FL 33703
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to weak capacitors. Replaced part start and test. Found water in float and recommend to clear drain with chemical. Performed work and first maintenance on system. Pressures good. Temp split good. Rinsed outdoor coil. Evap coil and blower starting to show growth and debris. Unit cooling at this time .
St. Petersburg, FL 33713
Upon arrival, I began troubleshooting the system by calling for cooling at the thermostat. The air handler energized and operated properly; however, the condenser was not running. Upon inspection, I found that low-voltage control power was present, but high-voltage power was not reaching the condenser.

I proceeded to the main electrical panel to verify power. The air conditioning breaker was not labeled, requiring additional troubleshooting to identify the correct circuit. After verifying the electrical supply, I returned to the condenser and reinstalled the disconnect. At that point, the system energized properly, and I confirmed 240 volts at the condenser.

I then performed a complete system diagnostic. The electrical components, refrigerant cycle, and overall system operation were all found to be within normal operating parameters. At this time, the system is functioning properly and no mechanical issues were identified.

I discussed my findings with the homeowner and recommended e
Upon arrival, I began troubleshooting the system by calling for cooling at the thermostat. The air handler energized and operated properly; however, the condenser was not running. Upon inspection, I found that low-voltage control power was present, but high-voltage power was not reaching the condenser.

I proceeded to the main electrical panel to verify power. The air conditioning breaker was not labeled, requiring additional troubleshooting to identify the correct circuit. After verifying the electrical supply, I returned to the condenser and reinstalled the disconnect. At that point, the system energized properly, and I confirmed 240 volts at the condenser.

I then performed a complete system diagnostic. The electrical components, refrigerant cycle, and overall system operation were all found to be within normal operating parameters. At this time, the system is functioning properly and no mechanical issues were identified.

I discussed my findings with the homeowner and recommended e
ihsan m.
ihsan m. Checked in
Upon arrival, I began troubleshooting the system by calling for cooling at the thermostat. The air handler energized and operated properly; however, the condenser was not running. Upon inspection, I found that low-voltage control power was present, but high-voltage power was not reaching the condenser. I proceeded to the main electrical panel to verify power. The air conditioning breaker was not labeled, requiring additional troubleshooting to identify the correct circuit. After verifying the electrical supply, I returned to the condenser and reinstalled the disconnect. At that point, the system energized properly, and I confirmed 240 volts at the condenser. I then performed a complete system diagnostic. The electrical components, refrigerant cycle, and overall system operation were all found to be within normal operating parameters. At this time, the system is functioning properly and no mechanical issues were identified. I discussed my findings with the homeowner and recommended e
St. Petersburg, FL 33704
Inspected gym units. Found 2 systems not cooling due to clogged drains. Inspected condensers and found 2 units with weak capacitors and below factory charge. 1 system has bad blower motor. Made all repairs necessary to get 3 systems cooling. Will send estimate for 4th unit to replace blower motor. Cleared pans and drains. Added chemical to help prevent growth. Added refrigerant back to factory specs. Replaced 2 weak capacitors. Units cooling and draining properly at this time. Units do not have filters and recommend to install this as soon as possible. Filter sizes are 23x20x1 for all 4 gym units.
Inspected gym units. Found 2 systems not cooling due to clogged drains. Inspected condensers and found 2 units with weak capacitors and below factory charge. 1 system has bad blower motor. Made all repairs necessary to get 3 systems cooling. Will send estimate for 4th unit to replace blower motor. Cleared pans and drains. Added chemical to help prevent growth. Added refrigerant back to factory specs. Replaced 2 weak capacitors. Units cooling and draining properly at this time. Units do not have filters and recommend to install this as soon as possible. Filter sizes are 23x20x1 for all 4 gym units.
Justin G.
Justin G. Checked in
Inspected gym units. Found 2 systems not cooling due to clogged drains. Inspected condensers and found 2 units with weak capacitors and below factory charge. 1 system has bad blower motor. Made all repairs necessary to get 3 systems cooling. Will send estimate for 4th unit to replace blower motor. Cleared pans and drains. Added chemical to help prevent growth. Added refrigerant back to factory specs. Replaced 2 weak capacitors. Units cooling and draining properly at this time. Units do not have filters and recommend to install this as soon as possible. Filter sizes are 23x20x1 for all 4 gym units.
St. Petersburg, FL 33705
Removed double tapped connection in panel 
Installed panel blanks in outside panel 
Tripped pool panel breaker reset it and tested equipment and breaker held
Removed double tapped connection in panel 
Installed panel blanks in outside panel 
Tripped pool panel breaker reset it and tested equipment and breaker held
Griffin K.
Griffin K. Checked in
Removed double tapped connection in panel Installed panel blanks in outside panel Tripped pool panel breaker reset it and tested equipment and breaker held
St. Petersburg, FL 33703
Review
Great service, came to my place the same day I called. Nate is a great communicator and technician; he kept me informed each step along the way. Nate and Griffin (the electrical technician) are honest, trustworthy, prompt, knowledgeable , and a pleasure to work with. Highly recommend!
Susan A. Valot - St. Petersburg, FL 33703
Response from Air Bros Air Conditioning & Electrical:

Thank you, Susan, for your wonderful 5-star rating; your support means a lot to us!

Review
I had an outstanding experience with Air Bros from the moment I scheduled my service through to the completion of the job. Nate arrived right on schedule and was incredibly professional from start to finish. He performed a thorough preventative maintenance and cleaning of our system with a high attention to detail. He took the time to check our entire system and went above and beyond to answer all my questions in detail about maintenance tips to help prevent future issues. Nate's expertise, friendly demeanor and professionalism along with the entire scheduling process were truly amazing!
Marci Gleicher - St. Petersburg, FL 33704
Response from Air Bros Air Conditioning & Electrical:

Thank you, Marci, for sharing your wonderful experience and recognizing Nate's professionalism and dedication; we truly appreciate your feedback and are glad to know our service met your expectations!

Review
Air Bros has been my go-to for HVAC since I bought my house in 2017, and I wouldnt trust anyone else! Ricky has kept my old unit running like a champ for years, and when my house recently flooded, Justin showed up to get it back up and runningbuying me some time before I finally replace it (after 20 years, its definitely earned its retirement!). Theyre always on time, know their stuff, and even a hit with my dogs. If you want honest, reliable, high-quality service in St. Pete, these guys are the way to go!
Amelia Johnson - St. Petersburg, FL 33704
Response from Air Bros Air Conditioning & Electrical:

Thank you, Amelia, for your kind words and for being a loyal customer since 2017! We're glad to hear that Ricky has kept your unit running smoothly and that Justin was there to help during a tough time. It means a lot to us to know we can provide reliable service for you and your furry friends!

Review
Nathan helped me out on very short notice, super professional and polite. Definitely will call again if need arises.
Ante Gotovina - St. Petersburg, FL 33704
Response from Air Bros Air Conditioning & Electrical:

Thank you, Ante, for your kind words about Nathan's professionalism and quick assistance; we look forward to helping you again in the future!

Contact the Bros You Know Today!

Schedule Service Online
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at 727-217-6148 .

By pressing Submit I agree to receive phone, email, or text messages from Air Bros Air Conditioning & Heating to the provided mobile number and also agree to the Air Bros Air Conditioning & Heating terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next