financing Special Offers Call Us Book Online

St. Petersburg, FL

air-bros-team-with-truck

Your St. Petersburg, FL HVAC Experts

Air Bros Air Conditioning & Heating is proud to serve the vibrant community of St. Petersburg, FL. We understand the unique challenges that St. Petersburg homeowners and businesses face when it comes to maintaining comfortable indoor temperatures year-round. Our team of experienced and certified technicians is dedicated to providing top-quality HVAC services tailored to the specific needs of our St. Petersburg customers.

Call us at 727-217-6148 or contact us online today for all of your HVAC, indoor air quality and electrical needs.

Comprehensive HVAC Services in St. Petersburg

We offer a full range of heating and cooling services to keep your St. Petersburg, FL, home comfortable year-round:

  • Air Conditioning: From AC repair and AC installation to routine maintenance, we ensure your cooling system keeps you comfortable during those hot Florida summers. We offer same-day service for AC emergencies, so you never have to suffer in the heat.
  • Heating: Stay warm and cozy in the winter with our comprehensive heating services. We repair and install all types of heating systems, including furnaces and heat pumps, and offer preventative maintenance to keep your system running efficiently.
  • Indoor Air Quality: Improve your indoor air quality with our dehumidifier and UV light installation services. We'll help you control excess humidity and eliminate airborne contaminants, creating a healthier home environment.
  • Ductwork: Ensure optimal airflow and energy efficiency with our ductwork repair and installation services. We can address leaks and damage, and design a system that's perfect for your home.
  • Pool Heater Services: Extend your swim season with our pool heater installation and repair services.
  • Electrical Services: From outlet and switch replacements to ceiling fan installations to whole-house surge protector installations, we have the experts to handle your electrical service needs.

Our experienced technicians are skilled in all aspects of HVAC service and are dedicated to providing top-quality workmanship and customer care.

Why Choose Air Bros?

  • Local Expertise: We understand the unique climate challenges of St. Petersburg.
  • Fast and Reliable Service: We offer same-day service for AC emergencies and prioritize prompt service for all your HVAC needs.
  • Experienced Technicians: Our team is highly trained and experienced in all aspects of HVAC service.
  • Upfront Pricing: We provide transparent pricing with no hidden costs.
  • Customer Satisfaction Guaranteed: Your comfort and satisfaction are our top priorities.

Contact Air Bros Today!

Whether you need emergency AC repair, a new heating system installation, or any other HVAC service, Air Bros is here to help. Contact us today for a free consultation or to schedule a service appointment. We're proud to be your trusted HVAC partner in St. Petersburg!

Call us at 727-217-6148 or contact us online today!

Our St. Petersburg Location

Address: 1579 Delaware Ave NESt. Petersburg, FL 33703

Phone: 727-217-6148

Count on perfect service; Trust the bros you know!

Recent Jobs and Reviews in St. Petersburg, FL

Job Locations and Reviews

Justin G.
Justin G. Checked in
On arrival found unit not cooling due to blown transformer. Replaced part. Found short in contactor causing blown fuses. Replaced contactor and new fuse. Start and test. Unit cooling. Unit cannot operate in heat at this time until sub panel is installed.
St. Petersburg, FL 33713
Replaced warranty TXV. Performed complimentary condenser coil cleaning. Performed complimentary drain line/primary drain pan cleaning and treatment. 
System is cooling and heating properly at this time with no other leaks.
Replaced warranty TXV. Performed complimentary condenser coil cleaning. Performed complimentary drain line/primary drain pan cleaning and treatment. 
System is cooling and heating properly at this time with no other leaks.
Michael A.
Michael A. Checked in
Replaced warranty TXV. Performed complimentary condenser coil cleaning. Performed complimentary drain line/primary drain pan cleaning and treatment. System is cooling and heating properly at this time with no other leaks.
St. Petersburg, FL 33703
St. Petersburg, FL - Performed maintenance on 3 systems. Found collapsed duct for main system. Found mini split low on refrigerant. Did not find leak at this time. Charged system to factory specs. All units cooling properly. Will submit estimates for mini split cleanings and duct repair.
Justin G.
Justin G. Checked in
Performed maintenance on 3 systems. Found collapsed duct for main system. Found mini split low on refrigerant. Did not find leak at this time. Charged system to factory specs. All units cooling properly. Will submit estimates for mini split cleanings and duct repair.
St. Petersburg, FL 33704
Home owner states unit maid a weird noise. Could not get system to imitate noise. Checked compressor and motor amps. Outdoor motor is pulling higher amps than rated for manufacture. Would recommend replacing to be pro active. System is 5 years old and home owner is not original owner of system. Outdoor electrical disconnect damage. Would recommend replacing. 

Air handler located in attic. Found large amount of bacterial growth acclimating on blower wheel and cabinet. Would recommend sanitizing cabinet and removing blower wheel to sanitize. 

Ductwork is not strap or sealed properly. Also found damaged 12” flex duct from rodent. Would recommend replacing duct.
Home owner states unit maid a weird noise. Could not get system to imitate noise. Checked compressor and motor amps. Outdoor motor is pulling higher amps than rated for manufacture. Would recommend replacing to be pro active. System is 5 years old and home owner is not original owner of system. Outdoor electrical disconnect damage. Would recommend replacing. 

Air handler located in attic. Found large amount of bacterial growth acclimating on blower wheel and cabinet. Would recommend sanitizing cabinet and removing blower wheel to sanitize. 

Ductwork is not strap or sealed properly. Also found damaged 12” flex duct from rodent. Would recommend replacing duct.
Nathan A.
Nathan A. Checked in
Home owner states unit maid a weird noise. Could not get system to imitate noise. Checked compressor and motor amps. Outdoor motor is pulling higher amps than rated for manufacture. Would recommend replacing to be pro active. System is 5 years old and home owner is not original owner of system. Outdoor electrical disconnect damage. Would recommend replacing. Air handler located in attic. Found large amount of bacterial growth acclimating on blower wheel and cabinet. Would recommend sanitizing cabinet and removing blower wheel to sanitize. Ductwork is not strap or sealed properly. Also found damaged 12” flex duct from rodent. Would recommend replacing duct.
St. Petersburg, FL 33704
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.

Inspected duct work and found holes in duct work. Duct work supply runs are not strapped up properly or sealed properly. There are multiple ducts burried under insulation or laying on top of eachother. The Duct System is also very old and we are recommending replacement at this time. Quote sent for replacement
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.

Inspected duct work and found holes in duct work. Duct work supply runs are not strapped up properly or sealed properly. There are multiple ducts burried under insulation or laying on top of eachother. The Duct System is also very old and we are recommending replacement at this time. Quote sent for replacement
Michael A.
Michael A. Checked in
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. Inspected duct work and found holes in duct work. Duct work supply runs are not strapped up properly or sealed properly. There are multiple ducts burried under insulation or laying on top of eachother. The Duct System is also very old and we are recommending replacement at this time. Quote sent for replacement
St. Petersburg, FL 33713
Home owner states unit in bedroom is making sounds. Blower wheel needs to be balanced and reinforced (zip screws). Home owner has two units that have not been serviced in 4-5 years. Would recommend maintenance on both systems. System in living room has no safety overflow switch. Would recommend installing to prevent overflow.
Home owner states unit in bedroom is making sounds. Blower wheel needs to be balanced and reinforced (zip screws). Home owner has two units that have not been serviced in 4-5 years. Would recommend maintenance on both systems. System in living room has no safety overflow switch. Would recommend installing to prevent overflow.
Nathan A.
Nathan A. Checked in
Home owner states unit in bedroom is making sounds. Blower wheel needs to be balanced and reinforced (zip screws). Home owner has two units that have not been serviced in 4-5 years. Would recommend maintenance on both systems. System in living room has no safety overflow switch. Would recommend installing to prevent overflow.
St. Petersburg, FL 33701
St. Petersburg, FL - On arrival found unit not working due to faulty nest thermostat causing unit to always run in heating mode. Replaced thermostat with new ecobee. Further inspection found worn contactor and weak capacitor on condenser. Replaced parts. Start and test. Unit operating properly at this time. Ecobee thermostat has 5 year parts warranty.
Justin G.
Justin G. Checked in
On arrival found unit not working due to faulty nest thermostat causing unit to always run in heating mode. Replaced thermostat with new ecobee. Further inspection found worn contactor and weak capacitor on condenser. Replaced parts. Start and test. Unit operating properly at this time. Ecobee thermostat has 5 year parts warranty.
St. Petersburg, FL 33703
Upon my inspection, found condenser breaker was tripped. Reset breaker and checked compressor for amp draw and Ohms. Checked capacitor. Checked wiring. Condenser is running properly. If issue happens again, we recommend replacing the breaker. Breaker size will be changed to a 30amp to match the condenser maximum overcurrent protection rating of 30. System is cooling at this time with a 23° temperature split.
Upon my inspection, found condenser breaker was tripped. Reset breaker and checked compressor for amp draw and Ohms. Checked capacitor. Checked wiring. Condenser is running properly. If issue happens again, we recommend replacing the breaker. Breaker size will be changed to a 30amp to match the condenser maximum overcurrent protection rating of 30. System is cooling at this time with a 23° temperature split.
Michael A.
Michael A. Checked in
Upon my inspection, found condenser breaker was tripped. Reset breaker and checked compressor for amp draw and Ohms. Checked capacitor. Checked wiring. Condenser is running properly. If issue happens again, we recommend replacing the breaker. Breaker size will be changed to a 30amp to match the condenser maximum overcurrent protection rating of 30. System is cooling at this time with a 23° temperature split.
St. Petersburg, FL 33713
Install bath fan 
Remove Current Ductwork
Remove Registers/Boots
Duct Balancing & Layout
Install Supply Flex Runs (10)
Install Collars & Couplers
Cut Ins for Returns/Supplies (4)
Risers/plenums etc
Install All Insulated Boots
Install New Ceiling Grilles
Seal Ceiling Grills
Seal & Mastic All Ductwork
Strap All Ductwork
Permitting
Install bath fan 
Remove Current Ductwork
Remove Registers/Boots
Duct Balancing & Layout
Install Supply Flex Runs (10)
Install Collars & Couplers
Cut Ins for Returns/Supplies (4)
Risers/plenums etc
Install All Insulated Boots
Install New Ceiling Grilles
Seal Ceiling Grills
Seal & Mastic All Ductwork
Strap All Ductwork
Permitting
Kyle K.
Kyle K. Checked in
Install bath fan Remove Current Ductwork Remove Registers/Boots Duct Balancing & Layout Install Supply Flex Runs (10) Install Collars & Couplers Cut Ins for Returns/Supplies (4) Risers/plenums etc Install All Insulated Boots Install New Ceiling Grilles Seal Ceiling Grills Seal & Mastic All Ductwork Strap All Ductwork Permitting
St. Petersburg, FL 33713
Installed new heater kit

Verified operations 

Unit is currently heating 

Removed diagnostic with repair (665$)
Installed new heater kit

Verified operations 

Unit is currently heating 

Removed diagnostic with repair (665$)
Nathan A.
Nathan A. Checked in
Installed new heater kit Verified operations Unit is currently heating Removed diagnostic with repair (665$)
St. Petersburg, FL 33702
Installation 2 air purifier and 2 UV lights
Installation 2 air purifier and 2 UV lights
Michael A.
Michael A. Checked in
Installation 2 air purifier and 2 UV lights
St. Petersburg, FL 33704
Home owner recommended by building manager for us to come out and bleed air from unit. Bled the unit until water came out. Air is out of system. Home owner also states unit will make loud banging noise. Explained that the actuator valve may need to be replaced. Also have buildup in drain pan. Would recommend having system maintenance. Unit is currently cooling.  

System met temp at 65° during visit. Was not able to imitate sound described.
Home owner recommended by building manager for us to come out and bleed air from unit. Bled the unit until water came out. Air is out of system. Home owner also states unit will make loud banging noise. Explained that the actuator valve may need to be replaced. Also have buildup in drain pan. Would recommend having system maintenance. Unit is currently cooling.  

System met temp at 65° during visit. Was not able to imitate sound described.
Nathan A.
Nathan A. Checked in
Home owner recommended by building manager for us to come out and bleed air from unit. Bled the unit until water came out. Air is out of system. Home owner also states unit will make loud banging noise. Explained that the actuator valve may need to be replaced. Also have buildup in drain pan. Would recommend having system maintenance. Unit is currently cooling. System met temp at 65° during visit. Was not able to imitate sound described.
St. Petersburg, FL 33701
Install a receptacle in the office area under desk for computers and equipment 
Install a dedicated 20 amp breaker in the pool sub panel 
Run conduit on the exterior then into a cut in box in the wall 
*** will need to special order brown receptacle and brown trim plate
Install a receptacle in the office area under desk for computers and equipment 
Install a dedicated 20 amp breaker in the pool sub panel 
Run conduit on the exterior then into a cut in box in the wall 
*** will need to special order brown receptacle and brown trim plate
Griffin  K.
Griffin K. Checked in
Install a receptacle in the office area under desk for computers and equipment Install a dedicated 20 amp breaker in the pool sub panel Run conduit on the exterior then into a cut in box in the wall *** will need to special order brown receptacle and brown trim plate
St. Petersburg, FL 33704
Performed Semi Annual Tuneup 

Condenser located on roof (elevator A to roof)

Condenser Recommendations 
-filter drier starting to rust out (recommend moving to interior)
-motor grate is starting to rust out (recommend replacing 
-Motor is starting to pull higher amps (potential failure point)

Air Handler Recommendations 
-current air purifier failed (recommend replacing to mitigate growth)
-air handler coils starting to rust (potential failure point)

Cleared drain line and drain pan 

Checked heating and cooling 

Checked starting components 

Unit is currently operating
Performed Semi Annual Tuneup 

Condenser located on roof (elevator A to roof)

Condenser Recommendations 
-filter drier starting to rust out (recommend moving to interior)
-motor grate is starting to rust out (recommend replacing 
-Motor is starting to pull higher amps (potential failure point)

Air Handler Recommendations 
-current air purifier failed (recommend replacing to mitigate growth)
-air handler coils starting to rust (potential failure point)

Cleared drain line and drain pan 

Checked heating and cooling 

Checked starting components 

Unit is currently operating
Nathan A.
Nathan A. Checked in
Performed Semi Annual Tuneup Condenser located on roof (elevator A to roof) Condenser Recommendations -filter drier starting to rust out (recommend moving to interior) -motor grate is starting to rust out (recommend replacing -Motor is starting to pull higher amps (potential failure point) Air Handler Recommendations -current air purifier failed (recommend replacing to mitigate growth) -air handler coils starting to rust (potential failure point) Cleared drain line and drain pan Checked heating and cooling Checked starting components Unit is currently operating
St. Petersburg, FL 33715
Performed Maitenences on systems. Cleaned/treated drain lines and primary drain pans. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switchs functionality. Checked amp draw on compressors. Checked amp draw on fan motors. Checked capacitors are within factory range. Made sure all connections are tight. Systems are cooling with 20° temperature splits at this time. Verified systems heat properly. 

Strapped up drain line on Ruud system air handler in attic. 

Found a duct run touching another duct and strapped it up to prevent moisture. Will look at it again in the summer time during next Maitenences.
Performed Maitenences on systems. Cleaned/treated drain lines and primary drain pans. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switchs functionality. Checked amp draw on compressors. Checked amp draw on fan motors. Checked capacitors are within factory range. Made sure all connections are tight. Systems are cooling with 20° temperature splits at this time. Verified systems heat properly. 

Strapped up drain line on Ruud system air handler in attic. 

Found a duct run touching another duct and strapped it up to prevent moisture. Will look at it again in the summer time during next Maitenences.
Michael A.
Michael A. Checked in
Performed Maitenences on systems. Cleaned/treated drain lines and primary drain pans. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switchs functionality. Checked amp draw on compressors. Checked amp draw on fan motors. Checked capacitors are within factory range. Made sure all connections are tight. Systems are cooling with 20° temperature splits at this time. Verified systems heat properly. Strapped up drain line on Ruud system air handler in attic. Found a duct run touching another duct and strapped it up to prevent moisture. Will look at it again in the summer time during next Maitenences.
St. Petersburg, FL 33704
St. Petersburg, FL - On arrival found unit not heating due to broken heat strip. Will submit estimate for heater replacement. No heat at this time.
Justin G.
Justin G. Checked in
On arrival found unit not heating due to broken heat strip. Will submit estimate for heater replacement. No heat at this time.
St. Petersburg, FL 33702
On arrival found unit low on refrigerant and attic has spray foam. Performed leak search and found no prominent leaks. Added refrigerant back to factory specs. Recommend to add dehumidifier in attic due to humidity issues in home. Unit operating properly at this time.
On arrival found unit low on refrigerant and attic has spray foam. Performed leak search and found no prominent leaks. Added refrigerant back to factory specs. Recommend to add dehumidifier in attic due to humidity issues in home. Unit operating properly at this time.
Justin G.
Justin G. Checked in
On arrival found unit low on refrigerant and attic has spray foam. Performed leak search and found no prominent leaks. Added refrigerant back to factory specs. Recommend to add dehumidifier in attic due to humidity issues in home. Unit operating properly at this time.
St. Petersburg, FL 33703
Replaced 10kw heater kit. Start and test. Unit has proper amps. Unit heating at this time.
Replaced 10kw heater kit. Start and test. Unit has proper amps. Unit heating at this time.
Justin G.
Justin G. Checked in
Replaced 10kw heater kit. Start and test. Unit has proper amps. Unit heating at this time.
St. Petersburg, FL 33713
Justin G.
Justin G. Checked in
On arrival found 10 kw heater running at half capacity due to bad circuit on heater. Will return to replace heater kit. Unit is heating to the best of its ability.
St. Petersburg, FL 33713
Upon my inspection, found downstairs system was cooling while the thermostat called for heating. System is a straight cool and thermostat was set up for heating pump. Reconfigured settings in google nest app. System is now heating properly. Verified system also cools when thermostat calls for cooling.
Upon my inspection, found downstairs system was cooling while the thermostat called for heating. System is a straight cool and thermostat was set up for heating pump. Reconfigured settings in google nest app. System is now heating properly. Verified system also cools when thermostat calls for cooling.
Michael A.
Michael A. Checked in
Upon my inspection, found downstairs system was cooling while the thermostat called for heating. System is a straight cool and thermostat was set up for heating pump. Reconfigured settings in google nest app. System is now heating properly. Verified system also cools when thermostat calls for cooling.
St. Petersburg, FL 33704
Upon my inspection, found low voltage fuse popped. Replaced fuse and tested cooling. System cools. Switched system to heat and fuse popped. Diagnosed bad contactor. Also found high voltage wire going to control board was fried in one section. Replaced contactor and repaired wire. System heats properly at this time. 
Inspected coils and evaporator coils are very badly impacted with debris. Coils need to be replaced or system replacement. Client would like to wait to replace system at this time.
Upon my inspection, found low voltage fuse popped. Replaced fuse and tested cooling. System cools. Switched system to heat and fuse popped. Diagnosed bad contactor. Also found high voltage wire going to control board was fried in one section. Replaced contactor and repaired wire. System heats properly at this time. 
Inspected coils and evaporator coils are very badly impacted with debris. Coils need to be replaced or system replacement. Client would like to wait to replace system at this time.
Michael A.
Michael A. Checked in
Upon my inspection, found low voltage fuse popped. Replaced fuse and tested cooling. System cools. Switched system to heat and fuse popped. Diagnosed bad contactor. Also found high voltage wire going to control board was fried in one section. Replaced contactor and repaired wire. System heats properly at this time. Inspected coils and evaporator coils are very badly impacted with debris. Coils need to be replaced or system replacement. Client would like to wait to replace system at this time.
St. Petersburg, FL 33710
Justin G.
Justin G. Checked in
Reprogrammed thermostat to work with electric heat. Found nd faulty float switch and replaced. Changed thermostat wire color to allow all settings to work properly. Function tested heat and cool. Unit operating properly at this time.
St. Petersburg, FL 33712
Upon arrival home owner states thermostat is blank and not cooling. Found low voltage fuse within air handler shorted. Found low voltage wiring in condenser rubbing out causing fuse to blow. Taped all wiring along with compressor high voltage. Replaced fuse and verified system operations. 

Found reversing valve not hooked up causing system to only run cooling. Spliced and connected wiring. Programmed Thermostat. Unit is heating and cooling 
Hooked up reversing valve in air handler and programmed Thermosat. No charge for fixing heat.
Upon arrival home owner states thermostat is blank and not cooling. Found low voltage fuse within air handler shorted. Found low voltage wiring in condenser rubbing out causing fuse to blow. Taped all wiring along with compressor high voltage. Replaced fuse and verified system operations. 

Found reversing valve not hooked up causing system to only run cooling. Spliced and connected wiring. Programmed Thermostat. Unit is heating and cooling 
Hooked up reversing valve in air handler and programmed Thermosat. No charge for fixing heat.
Nathan A.
Nathan A. Checked in
Upon arrival home owner states thermostat is blank and not cooling. Found low voltage fuse within air handler shorted. Found low voltage wiring in condenser rubbing out causing fuse to blow. Taped all wiring along with compressor high voltage. Replaced fuse and verified system operations. Found reversing valve not hooked up causing system to only run cooling. Spliced and connected wiring. Programmed Thermostat. Unit is heating and cooling Hooked up reversing valve in air handler and programmed Thermosat. No charge for fixing heat.
St. Petersburg, FL 33703
Justin G.
Justin G. Checked in
Install condensate pump for upstairs unit. Clear drain with chemical. Connect float switch to pump. Tax and labor included.
St. Petersburg, FL 33704
Performed Maitenences on systems. Cleaned/treated drain lines and primary drain pans. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switchs functionality. Checked amp draw on compressors. Checked amp draw on fan motors. Checked capacitors are within factory range. System 1 capacitor is out of factory range. Replaced capacitor . Made sure all connections are tight. Systems are cooling with 20° temperature splits at this time. Verified systems heat properly. 

System #2 back up auxiliary heat element was disconnected. Verified heating element is working properly and reconnected it. If issue happens in the future, is is possible that there is an intermittent issue where the heating element relay gets stuck and keeps the heating on while in cooling mode. 

Air handler #1 has visible growth inside on wiring, coils, metal, and the primary drain pan. We recommend cleaning and installing a UV air treatment system inside the air handler. Sending quote for cleaning/i
Performed Maitenences on systems. Cleaned/treated drain lines and primary drain pans. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switchs functionality. Checked amp draw on compressors. Checked amp draw on fan motors. Checked capacitors are within factory range. System 1 capacitor is out of factory range. Replaced capacitor . Made sure all connections are tight. Systems are cooling with 20° temperature splits at this time. Verified systems heat properly. 

System #2 back up auxiliary heat element was disconnected. Verified heating element is working properly and reconnected it. If issue happens in the future, is is possible that there is an intermittent issue where the heating element relay gets stuck and keeps the heating on while in cooling mode. 

Air handler #1 has visible growth inside on wiring, coils, metal, and the primary drain pan. We recommend cleaning and installing a UV air treatment system inside the air handler. Sending quote for cleaning/i
Michael A.
Michael A. Checked in
Performed Maitenences on systems. Cleaned/treated drain lines and primary drain pans. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switchs functionality. Checked amp draw on compressors. Checked amp draw on fan motors. Checked capacitors are within factory range. System 1 capacitor is out of factory range. Replaced capacitor . Made sure all connections are tight. Systems are cooling with 20° temperature splits at this time. Verified systems heat properly. System #2 back up auxiliary heat element was disconnected. Verified heating element is working properly and reconnected it. If issue happens in the future, is is possible that there is an intermittent issue where the heating element relay gets stuck and keeps the heating on while in cooling mode. Air handler #1 has visible growth inside on wiring, coils, metal, and the primary drain pan. We recommend cleaning and installing a UV air treatment system inside the air handler. Sending quote for cleaning/i
St. Petersburg, FL 33703
Review
Great service, came to my place the same day I called. Nate is a great communicator and technician; he kept me informed each step along the way. Nate and Griffin (the electrical technician) are honest, trustworthy, prompt, knowledgeable , and a pleasure to work with. Highly recommend!
Susan A. Valot - St. Petersburg, FL 33703
Response from Air Bros Air Conditioning & Electrical:

Thank you, Susan, for your wonderful 5-star rating; your support means a lot to us!

Review
I had an outstanding experience with Air Bros from the moment I scheduled my service through to the completion of the job. Nate arrived right on schedule and was incredibly professional from start to finish. He performed a thorough preventative maintenance and cleaning of our system with a high attention to detail. He took the time to check our entire system and went above and beyond to answer all my questions in detail about maintenance tips to help prevent future issues. Nate's expertise, friendly demeanor and professionalism along with the entire scheduling process were truly amazing!
Marci Gleicher - St. Petersburg, FL 33704
Response from Air Bros Air Conditioning & Electrical:

Thank you, Marci, for sharing your wonderful experience and recognizing Nate's professionalism and dedication; we truly appreciate your feedback and are glad to know our service met your expectations!

Review
Air Bros has been my go-to for HVAC since I bought my house in 2017, and I wouldnt trust anyone else! Ricky has kept my old unit running like a champ for years, and when my house recently flooded, Justin showed up to get it back up and runningbuying me some time before I finally replace it (after 20 years, its definitely earned its retirement!). Theyre always on time, know their stuff, and even a hit with my dogs. If you want honest, reliable, high-quality service in St. Pete, these guys are the way to go!
Amelia Johnson - St. Petersburg, FL 33704
Response from Air Bros Air Conditioning & Electrical:

Thank you, Amelia, for your kind words and for being a loyal customer since 2017! We're glad to hear that Ricky has kept your unit running smoothly and that Justin was there to help during a tough time. It means a lot to us to know we can provide reliable service for you and your furry friends!

Review
Nathan helped me out on very short notice, super professional and polite. Definitely will call again if need arises.
Ante Gotovina - St. Petersburg, FL 33704
Response from Air Bros Air Conditioning & Electrical:

Thank you, Ante, for your kind words about Nathan's professionalism and quick assistance; we look forward to helping you again in the future!

Contact the Bros You Know Today!

Schedule Service Online
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at 727-217-6148 .

By pressing Submit I agree to receive phone, email, or text messages from Air Bros Air Conditioning & Heating to the provided mobile number and also agree to the Air Bros Air Conditioning & Heating terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next