Instant Quote Shop Filters Call Air Bros Book Service

St. Petersburg, FL

air-bros-team-with-truck

Your St. Petersburg, FL HVAC Experts

Air Bros Air Conditioning & Heating is proud to serve the vibrant community of St. Petersburg, FL. We understand the unique challenges that St. Petersburg homeowners and businesses face when it comes to maintaining comfortable indoor temperatures year-round. Our team of experienced and certified technicians is dedicated to providing top-quality HVAC services tailored to the specific needs of our St. Petersburg customers.

Call us at 727-217-6148 or contact us online today for all of your HVAC, indoor air quality and electrical needs.

Comprehensive HVAC Services in St. Petersburg

We offer a full range of heating and cooling services to keep your St. Petersburg, FL, home comfortable year-round:

  • Air Conditioning: From AC repair and AC installation to routine maintenance, we ensure your cooling system keeps you comfortable during those hot Florida summers. We offer same-day service for AC emergencies, so you never have to suffer in the heat.
  • Heating: Stay warm and cozy in the winter with our comprehensive heating services. We repair and install all types of heating systems, including furnaces and heat pumps, and offer preventative maintenance to keep your system running efficiently.
  • Indoor Air Quality: Improve your indoor air quality with our dehumidifier and UV light installation services. We'll help you control excess humidity and eliminate airborne contaminants, creating a healthier home environment.
  • Ductwork: Ensure optimal airflow and energy efficiency with our ductwork repair and installation services. We can address leaks and damage, and design a system that's perfect for your home.
  • Pool Heater Services: Extend your swim season with our pool heater installation and repair services.
  • Electrical Services: From outlet and switch replacements to ceiling fan installations to whole-house surge protector installations, we have the experts to handle your electrical service needs.

Our experienced technicians are skilled in all aspects of HVAC service and are dedicated to providing top-quality workmanship and customer care.

Why Choose Air Bros?

  • Local Expertise: We understand the unique climate challenges of St. Petersburg.
  • Fast and Reliable Service: We offer same-day service for AC emergencies and prioritize prompt service for all your HVAC needs.
  • Experienced Technicians: Our team is highly trained and experienced in all aspects of HVAC service.
  • Upfront Pricing: We provide transparent pricing with no hidden costs.
  • Customer Satisfaction Guaranteed: Your comfort and satisfaction are our top priorities.

Contact Air Bros Today!

Whether you need emergency AC repair, a new heating system installation, or any other HVAC service, Air Bros is here to help. Contact us today for a free consultation or to schedule a service appointment. We're proud to be your trusted HVAC partner in St. Petersburg!

Call us at 727-217-6148 or contact us online today!

Our St. Petersburg Location

Address: 1579 Delaware Ave NESt. Petersburg, FL 33703

Phone: 727-217-6148

Count on perfect service; Trust the bros you know!

Recent Jobs and Reviews in St. Petersburg, FL

Job Locations and Reviews

Upon arrival, I started by checking the temperature differential and measured a 20°F split, which is within the normal operating range. I then evaluated the refrigerant cycle and found no signs of leaks or restrictions at this time. Moving on to the electrical components, all readings were within manufacturer specifications, and no electrical issues were found.

I performed a drain line treatment, condenser coil cleaning, and a complete air handler inspection. The homeowner is already maintaining the system well with preventative maintenance measures in place. At this time, no repair recommendations are necessary, as the system is operating properly and all components appear to be functioning as designed.
Upon arrival, I started by checking the temperature differential and measured a 20°F split, which is within the normal operating range. I then evaluated the refrigerant cycle and found no signs of leaks or restrictions at this time. Moving on to the electrical components, all readings were within manufacturer specifications, and no electrical issues were found.

I performed a drain line treatment, condenser coil cleaning, and a complete air handler inspection. The homeowner is already maintaining the system well with preventative maintenance measures in place. At this time, no repair recommendations are necessary, as the system is operating properly and all components appear to be functioning as designed.
ihsan m.
ihsan m. Checked in
Upon arrival, I started by checking the temperature differential and measured a 20°F split, which is within the normal operating range. I then evaluated the refrigerant cycle and found no signs of leaks or restrictions at this time. Moving on to the electrical components, all readings were within manufacturer specifications, and no electrical issues were found. I performed a drain line treatment, condenser coil cleaning, and a complete air handler inspection. The homeowner is already maintaining the system well with preventative maintenance measures in place. At this time, no repair recommendations are necessary, as the system is operating properly and all components appear to be functioning as designed.
St. Petersburg, FL 33702
On arrival found unit not keeping up due to low refrigerant levels. Performed leak search on system and found leak in suction line. Made repairs. Pulled vacuum on system to check for leaks. Weighed in factory charge. Start and test. Unit cooling properly at this time.
On arrival found unit not keeping up due to low refrigerant levels. Performed leak search on system and found leak in suction line. Made repairs. Pulled vacuum on system to check for leaks. Weighed in factory charge. Start and test. Unit cooling properly at this time.
Justin G.
Justin G. Checked in
On arrival found unit not keeping up due to low refrigerant levels. Performed leak search on system and found leak in suction line. Made repairs. Pulled vacuum on system to check for leaks. Weighed in factory charge. Start and test. Unit cooling properly at this time.
St. Petersburg, FL 33704
Reason for call:
No cool mini split 

Equipment:
Single zone Mitsubishi mini split 

Summary:
Completed diagnosis to find a splice in com wire. This splice joint was holding a couple ounces of water. Unraveled tape to find corrosion on wire nut connections. Redid splice joints cut out corroded wires and resealed splice with new electrical tape all wire nuts points up to prevent this again. 

If problem persists we will have to replace com wire from indoor to outdoor units.
Reason for call:
No cool mini split 

Equipment:
Single zone Mitsubishi mini split 

Summary:
Completed diagnosis to find a splice in com wire. This splice joint was holding a couple ounces of water. Unraveled tape to find corrosion on wire nut connections. Redid splice joints cut out corroded wires and resealed splice with new electrical tape all wire nuts points up to prevent this again. 

If problem persists we will have to replace com wire from indoor to outdoor units.
Corbin C.
Corbin C. Checked in
Reason for call: No cool mini split Equipment: Single zone Mitsubishi mini split Summary: Completed diagnosis to find a splice in com wire. This splice joint was holding a couple ounces of water. Unraveled tape to find corrosion on wire nut connections. Redid splice joints cut out corroded wires and resealed splice with new electrical tape all wire nuts points up to prevent this again. If problem persists we will have to replace com wire from indoor to outdoor units.
St. Petersburg, FL 33704
Minor Duct seal
Minor Duct seal
Martin W.
Martin W. Checked in
Minor Duct seal
St. Petersburg, FL 33711
Diagnostic 
-outdoor unit going off on high pressure alarm due to fan motor not operating. Found capacitor failed causing unit not to run 

Scope of work 
-replaced failed outdoor capacitor 
-cleaned up service department 

Verified system operations after completing repairs. Unit is operating within manufacture specifications 

Further Notes 
-unit does not look to have had proper maintenance. Outdoor unit has debris inside condenser. Indoor drain has not been cleared.
Diagnostic 
-outdoor unit going off on high pressure alarm due to fan motor not operating. Found capacitor failed causing unit not to run 

Scope of work 
-replaced failed outdoor capacitor 
-cleaned up service department 

Verified system operations after completing repairs. Unit is operating within manufacture specifications 

Further Notes 
-unit does not look to have had proper maintenance. Outdoor unit has debris inside condenser. Indoor drain has not been cleared.
Nathan A.
Nathan A. Checked in
Diagnostic -outdoor unit going off on high pressure alarm due to fan motor not operating. Found capacitor failed causing unit not to run Scope of work -replaced failed outdoor capacitor -cleaned up service department Verified system operations after completing repairs. Unit is operating within manufacture specifications Further Notes -unit does not look to have had proper maintenance. Outdoor unit has debris inside condenser. Indoor drain has not been cleared.
St. Petersburg, FL 33702
Upon inspection, the blower motor is showing signs of intermittent failure and is nearing the end of its service life. I discussed the findings with the homeowner, and at this time they do not wish to invest in repairs. The homeowner would like to review replacement options with his wife before making a decision.

Please provide both a repair estimate and a full system replacement proposal. The homeowner has requested that we follow up on Monday to discuss the available options and next steps.
Upon inspection, the blower motor is showing signs of intermittent failure and is nearing the end of its service life. I discussed the findings with the homeowner, and at this time they do not wish to invest in repairs. The homeowner would like to review replacement options with his wife before making a decision.

Please provide both a repair estimate and a full system replacement proposal. The homeowner has requested that we follow up on Monday to discuss the available options and next steps.
ihsan m.
ihsan m. Checked in
Upon inspection, the blower motor is showing signs of intermittent failure and is nearing the end of its service life. I discussed the findings with the homeowner, and at this time they do not wish to invest in repairs. The homeowner would like to review replacement options with his wife before making a decision. Please provide both a repair estimate and a full system replacement proposal. The homeowner has requested that we follow up on Monday to discuss the available options and next steps.
St. Petersburg, FL 33714
Home owner states other company told them they need a condensate pump. Found indoor trap heavily backed up and line not properly cleared. Blew out line with nitrogen, cleared drain pan, added drain solve, added pan tablets to help with buildup. Unit is now clear and draining properly. Outdoor drain has backwards pitch. Put a piece of wood to weigh down drain for proper drainage. 

Checked indoor components for water damage. Plate beneath gas valve and components has rust due to water dripping on it. Unit is currently operating and no other issues at this time.
Home owner states other company told them they need a condensate pump. Found indoor trap heavily backed up and line not properly cleared. Blew out line with nitrogen, cleared drain pan, added drain solve, added pan tablets to help with buildup. Unit is now clear and draining properly. Outdoor drain has backwards pitch. Put a piece of wood to weigh down drain for proper drainage. 

Checked indoor components for water damage. Plate beneath gas valve and components has rust due to water dripping on it. Unit is currently operating and no other issues at this time.
Nathan A.
Nathan A. Checked in
Home owner states other company told them they need a condensate pump. Found indoor trap heavily backed up and line not properly cleared. Blew out line with nitrogen, cleared drain pan, added drain solve, added pan tablets to help with buildup. Unit is now clear and draining properly. Outdoor drain has backwards pitch. Put a piece of wood to weigh down drain for proper drainage. Checked indoor components for water damage. Plate beneath gas valve and components has rust due to water dripping on it. Unit is currently operating and no other issues at this time.
St. Petersburg, FL 33703
Upon arrival, I began by inspecting the condensate drain system and found that the float switch had been triggered. The secondary drain pan was completely full of water due to a clogged drain line. I cleared the blockage and performed a temporary startup to evaluate the system’s operation.

During testing, the system achieved a 17°F temperature split, which is within an acceptable operating range. All major components are currently functioning properly. However, the system was manufactured in 2003 and is well beyond its typical life expectancy. Due to the age and condition of the equipment, mechanical repairs are generally not recommended should a major component fail in the future.

I discussed the overall condition of the system with the homeowner and advised them to keep potential system replacement in mind as the equipment continues to age. To help monitor the system’s performance and catch issues before they become major problems, I offered a maintenance agreement that includes in
Upon arrival, I began by inspecting the condensate drain system and found that the float switch had been triggered. The secondary drain pan was completely full of water due to a clogged drain line. I cleared the blockage and performed a temporary startup to evaluate the system’s operation.

During testing, the system achieved a 17°F temperature split, which is within an acceptable operating range. All major components are currently functioning properly. However, the system was manufactured in 2003 and is well beyond its typical life expectancy. Due to the age and condition of the equipment, mechanical repairs are generally not recommended should a major component fail in the future.

I discussed the overall condition of the system with the homeowner and advised them to keep potential system replacement in mind as the equipment continues to age. To help monitor the system’s performance and catch issues before they become major problems, I offered a maintenance agreement that includes in
ihsan m.
ihsan m. Checked in
Upon arrival, I began by inspecting the condensate drain system and found that the float switch had been triggered. The secondary drain pan was completely full of water due to a clogged drain line. I cleared the blockage and performed a temporary startup to evaluate the system’s operation. During testing, the system achieved a 17°F temperature split, which is within an acceptable operating range. All major components are currently functioning properly. However, the system was manufactured in 2003 and is well beyond its typical life expectancy. Due to the age and condition of the equipment, mechanical repairs are generally not recommended should a major component fail in the future. I discussed the overall condition of the system with the homeowner and advised them to keep potential system replacement in mind as the equipment continues to age. To help monitor the system’s performance and catch issues before they become major problems, I offered a maintenance agreement that includes in
St. Petersburg, FL 33704
2017 Goodman Straight Cool

Diagnostic 
-drain line backing up causing system to intermittently cycle 
-outdoor capacitor very weak and rusted 

Scope of work 
-cut drain line and blow out with nitrogen 
-install clean out for tenant 
-clear drain pan & prime trap 
-added pan tablets to help with buildup 
-replaced outdoor 50/5 capacitor 

Further Notes 
-indoor air handler coils impacted with debris 
-outdoor coils corroded due to being close to water 
-outdoor contactor pitted and corroded 
-outdoor high voltage disconnect rusted & corroded 
-indoor disconnect marked bad

Verified system operations after completing work. System had a 16° temp split and cooling best of abilities 

Told home owner about system conditions and to look at replacing in future 


Discounted repairs from 695$ to 595$
2017 Goodman Straight Cool

Diagnostic 
-drain line backing up causing system to intermittently cycle 
-outdoor capacitor very weak and rusted 

Scope of work 
-cut drain line and blow out with nitrogen 
-install clean out for tenant 
-clear drain pan & prime trap 
-added pan tablets to help with buildup 
-replaced outdoor 50/5 capacitor 

Further Notes 
-indoor air handler coils impacted with debris 
-outdoor coils corroded due to being close to water 
-outdoor contactor pitted and corroded 
-outdoor high voltage disconnect rusted & corroded 
-indoor disconnect marked bad

Verified system operations after completing work. System had a 16° temp split and cooling best of abilities 

Told home owner about system conditions and to look at replacing in future 


Discounted repairs from 695$ to 595$
Nathan A.
Nathan A. Checked in
2017 Goodman Straight Cool Diagnostic -drain line backing up causing system to intermittently cycle -outdoor capacitor very weak and rusted Scope of work -cut drain line and blow out with nitrogen -install clean out for tenant -clear drain pan & prime trap -added pan tablets to help with buildup -replaced outdoor 50/5 capacitor Further Notes -indoor air handler coils impacted with debris -outdoor coils corroded due to being close to water -outdoor contactor pitted and corroded -outdoor high voltage disconnect rusted & corroded -indoor disconnect marked bad Verified system operations after completing work. System had a 16° temp split and cooling best of abilities Told home owner about system conditions and to look at replacing in future Discounted repairs from 695$ to 595$
St. Petersburg, FL 33715
Upon my inspection, downstairs unit is not keeping up with temperature. Found that the drain line was clogged. Performed a drain cleaning and treatment. Found that the drain line was very bad and had to take apart to clean. 30 day guarantee on drain cleaning. Maintenence is not due for another three months.
Upon my inspection, downstairs unit is not keeping up with temperature. Found that the drain line was clogged. Performed a drain cleaning and treatment. Found that the drain line was very bad and had to take apart to clean. 30 day guarantee on drain cleaning. Maintenence is not due for another three months.
Michael A.
Michael A. Checked in
Upon my inspection, downstairs unit is not keeping up with temperature. Found that the drain line was clogged. Performed a drain cleaning and treatment. Found that the drain line was very bad and had to take apart to clean. 30 day guarantee on drain cleaning. Maintenence is not due for another three months.
St. Petersburg, FL 33716
Replace warranty blower motor. Start and test. Tax and labor included.
Replace warranty blower motor. Start and test. Tax and labor included.
ihsan m.
ihsan m. Checked in
Replace warranty blower motor. Start and test. Tax and labor included.
St. Petersburg, FL 33704
Reason for call:
System not keeping up 

Equipment:
2019 trane 4 ton 
Vertical in garage 
Condenser on right side of home 

Summary:
On arrival I found system not going into second stage. Found no low voltage calling for second stage. Confirmed no calling at ah. Did continuity test between stage one and stage two of cooling. Confirmed wire was good. Related to a thermostat failed for calling on stage two.  Replace thermostat with ecobee thermostat. First stage two was restored. Proper pressures proper temperatures.
Reason for call:
System not keeping up 

Equipment:
2019 trane 4 ton 
Vertical in garage 
Condenser on right side of home 

Summary:
On arrival I found system not going into second stage. Found no low voltage calling for second stage. Confirmed no calling at ah. Did continuity test between stage one and stage two of cooling. Confirmed wire was good. Related to a thermostat failed for calling on stage two.  Replace thermostat with ecobee thermostat. First stage two was restored. Proper pressures proper temperatures.
Corbin C.
Corbin C. Checked in
Reason for call: System not keeping up Equipment: 2019 trane 4 ton Vertical in garage Condenser on right side of home Summary: On arrival I found system not going into second stage. Found no low voltage calling for second stage. Confirmed no calling at ah. Did continuity test between stage one and stage two of cooling. Confirmed wire was good. Related to a thermostat failed for calling on stage two. Replace thermostat with ecobee thermostat. First stage two was restored. Proper pressures proper temperatures.
St. Petersburg, FL 33702
Griffin K.
Griffin K. Checked in
Replace tripping ac breaker
St. Petersburg, FL 33709
Client state system stuff working yesterday. Upon my inspection, found bad capacitor and old contactor. Replaced both components and started system. Compressor and fan motor amp draws are good. Compressor startup amp draw is over camping. Let Client know that this may become a future issue. 
Pulling at this time with a 20° temperature split
Client state system stuff working yesterday. Upon my inspection, found bad capacitor and old contactor. Replaced both components and started system. Compressor and fan motor amp draws are good. Compressor startup amp draw is over camping. Let Client know that this may become a future issue. 
Pulling at this time with a 20° temperature split
Michael A.
Michael A. Checked in
Client state system stuff working yesterday. Upon my inspection, found bad capacitor and old contactor. Replaced both components and started system. Compressor and fan motor amp draws are good. Compressor startup amp draw is over camping. Let Client know that this may become a future issue. Pulling at this time with a 20° temperature split
St. Petersburg, FL 33702
Home owner states unit has had several issues since installed. Sub contractor installed unit.

Unit does not look to be professionally installed. Home owner has had several companies tell her same 

Air handler notes 
-no filter drier 
-no primary safety switch (potential water damage)

Outdoor notes 
-outdoor board failing 
-outdoor low pressure switch bypassed (switch has failed)

Went over issues with install and repairs needed. Went over options for new system 

Outdoor unit intermittently shutting off. Unit will continue to short cycle until repairs or replacement. Explained electric bill will be high.
Home owner states unit has had several issues since installed. Sub contractor installed unit.

Unit does not look to be professionally installed. Home owner has had several companies tell her same 

Air handler notes 
-no filter drier 
-no primary safety switch (potential water damage)

Outdoor notes 
-outdoor board failing 
-outdoor low pressure switch bypassed (switch has failed)

Went over issues with install and repairs needed. Went over options for new system 

Outdoor unit intermittently shutting off. Unit will continue to short cycle until repairs or replacement. Explained electric bill will be high.
Nathan A.
Nathan A. Checked in
Home owner states unit has had several issues since installed. Sub contractor installed unit. Unit does not look to be professionally installed. Home owner has had several companies tell her same Air handler notes -no filter drier -no primary safety switch (potential water damage) Outdoor notes -outdoor board failing -outdoor low pressure switch bypassed (switch has failed) Went over issues with install and repairs needed. Went over options for new system Outdoor unit intermittently shutting off. Unit will continue to short cycle until repairs or replacement. Explained electric bill will be high.
St. Petersburg, FL 33711
Upon my inspection, found capacitor, contactar, and wiring in the condenser burnt up and faulty. 
Replaced capacitor, contactar, and new connectors on wiring. 

System is cooling at this time with a 20° temp split. 
System is a 2010 and furnace is from 1992. Recommended that client prepare for new system due to age and condition. Sending quote over for replacement by tonight. 

No guarantee on repairs today due to system age and condition.
Upon my inspection, found capacitor, contactar, and wiring in the condenser burnt up and faulty. 
Replaced capacitor, contactar, and new connectors on wiring. 

System is cooling at this time with a 20° temp split. 
System is a 2010 and furnace is from 1992. Recommended that client prepare for new system due to age and condition. Sending quote over for replacement by tonight. 

No guarantee on repairs today due to system age and condition.
Michael A.
Michael A. Checked in
Upon my inspection, found capacitor, contactar, and wiring in the condenser burnt up and faulty. Replaced capacitor, contactar, and new connectors on wiring. System is cooling at this time with a 20° temp split. System is a 2010 and furnace is from 1992. Recommended that client prepare for new system due to age and condition. Sending quote over for replacement by tonight. No guarantee on repairs today due to system age and condition.
St. Petersburg, FL 33708
Check in with tower 175 to gain access. COI on file 

Maintenance needed to allow access for roof unit 

Home owner states she changed filter and unit stopped working. Home owner bumped wiring to secondary safety switch. Added wire nut and taped wires to side for home owner.

Performed tuneup on system 

Air handler notes
-coils heavily rusted 
-blower wheel & assembly accumulating bacterial growth 

Outdoor condenser notes 
-filter drier heavily rusted 
-coils starting to corrode 
-capacitor rusted and weak 
-contactor heavily pitted and rusted 

Rooftop units close to water
Check in with tower 175 to gain access. COI on file 

Maintenance needed to allow access for roof unit 

Home owner states she changed filter and unit stopped working. Home owner bumped wiring to secondary safety switch. Added wire nut and taped wires to side for home owner.

Performed tuneup on system 

Air handler notes
-coils heavily rusted 
-blower wheel & assembly accumulating bacterial growth 

Outdoor condenser notes 
-filter drier heavily rusted 
-coils starting to corrode 
-capacitor rusted and weak 
-contactor heavily pitted and rusted 

Rooftop units close to water
Nathan A.
Nathan A. Checked in
Check in with tower 175 to gain access. COI on file Maintenance needed to allow access for roof unit Home owner states she changed filter and unit stopped working. Home owner bumped wiring to secondary safety switch. Added wire nut and taped wires to side for home owner. Performed tuneup on system Air handler notes -coils heavily rusted -blower wheel & assembly accumulating bacterial growth Outdoor condenser notes -filter drier heavily rusted -coils starting to corrode -capacitor rusted and weak -contactor heavily pitted and rusted Rooftop units close to water
St. Petersburg, FL 33701
Full System Tuneup 

Unit is operating within manufacture specifications
Full System Tuneup 

Unit is operating within manufacture specifications
Nathan A.
Nathan A. Checked in
Full System Tuneup Unit is operating within manufacture specifications
St. Petersburg, FL 33702
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.
Michael A.
Michael A. Checked in
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.
St. Petersburg, FL 33703
Unit not cooling due to clogged drain line tripping safety. Cleared drain line and drain pan. Added pan tabs to help with buildup. Verified system operations and drainage. 

Home owner would like to move forward with maintenance plan
Unit not cooling due to clogged drain line tripping safety. Cleared drain line and drain pan. Added pan tabs to help with buildup. Verified system operations and drainage. 

Home owner would like to move forward with maintenance plan
Nathan A.
Nathan A. Checked in
Unit not cooling due to clogged drain line tripping safety. Cleared drain line and drain pan. Added pan tabs to help with buildup. Verified system operations and drainage. Home owner would like to move forward with maintenance plan
St. Petersburg, FL 33711
Upon my inspection, found tripped air handler breaker. Tried to reset breaker and it continued to trip. Turned power off by the breakered disconnect at the air handler and reset main breaker. Power stayed on. Disconnected blower motor high voltage plug and turned air handler breaker disconnect at unit back on and power still on. Turned off and reconnected blower motor and turned power back on. System is cooling at this time with a 24° temp split. Coils are a little dirty. 
Advised client that if issue persists, we will need to start replacing breakers if they are weak.
Upon my inspection, found tripped air handler breaker. Tried to reset breaker and it continued to trip. Turned power off by the breakered disconnect at the air handler and reset main breaker. Power stayed on. Disconnected blower motor high voltage plug and turned air handler breaker disconnect at unit back on and power still on. Turned off and reconnected blower motor and turned power back on. System is cooling at this time with a 24° temp split. Coils are a little dirty. 
Advised client that if issue persists, we will need to start replacing breakers if they are weak.
Michael A.
Michael A. Checked in
Upon my inspection, found tripped air handler breaker. Tried to reset breaker and it continued to trip. Turned power off by the breakered disconnect at the air handler and reset main breaker. Power stayed on. Disconnected blower motor high voltage plug and turned air handler breaker disconnect at unit back on and power still on. Turned off and reconnected blower motor and turned power back on. System is cooling at this time with a 24° temp split. Coils are a little dirty. Advised client that if issue persists, we will need to start replacing breakers if they are weak.
St. Petersburg, FL 33709
Home owner states filters changed and drain line cleared. Upon arrival found outdoor disconnect pulled to condenser. 

Diagnostic 
-failed outdoor capacitor 
-pitted and rusted contactor 

Scope of Work
-replace & wire capacitor 
-replace and wire contactor

Verified amp draws and system operations after completing repairs. No issues at this time. 
Discount from 695$ to 595$
Home owner states filters changed and drain line cleared. Upon arrival found outdoor disconnect pulled to condenser. 

Diagnostic 
-failed outdoor capacitor 
-pitted and rusted contactor 

Scope of Work
-replace & wire capacitor 
-replace and wire contactor

Verified amp draws and system operations after completing repairs. No issues at this time. 
Discount from 695$ to 595$
Nathan A.
Nathan A. Checked in
Home owner states filters changed and drain line cleared. Upon arrival found outdoor disconnect pulled to condenser. Diagnostic -failed outdoor capacitor -pitted and rusted contactor Scope of Work -replace & wire capacitor -replace and wire contactor Verified amp draws and system operations after completing repairs. No issues at this time. Discount from 695$ to 595$
St. Petersburg, FL 33710
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.

Found dead lizard and frog on capacitor. Tested capacitor and it is within its factory spec. 

Recommended Maitenence plan.
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time.

Found dead lizard and frog on capacitor. Tested capacitor and it is within its factory spec. 

Recommended Maitenence plan.
Michael A.
Michael A. Checked in
Performed Maitenence on system. Cleaned/treated drain line and primary drain pan. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switch functionality. Checked amp draw on compressor. Checked amp draw on fan motor. Checked capacitor is within factory range. Inspected Contactar. Made sure all connections are tight. System is cooling with a 20° temperature split at this time. Found dead lizard and frog on capacitor. Tested capacitor and it is within its factory spec. Recommended Maitenence plan.
St. Petersburg, FL 33709
Scope of work:
- Reseal supply plenum
- Add 2lbs refrigerant (no guarantee due to mix match system)
- replace control board under parts warranty. 
- replace fan motor wiring harness under parts warranty. 

**did not add refrigerant per clients request to save money for now**
Scope of work:
- Reseal supply plenum
- Add 2lbs refrigerant (no guarantee due to mix match system)
- replace control board under parts warranty. 
- replace fan motor wiring harness under parts warranty. 

**did not add refrigerant per clients request to save money for now**
Michael A.
Michael A. Checked in
Scope of work: - Reseal supply plenum - Add 2lbs refrigerant (no guarantee due to mix match system) - replace control board under parts warranty. - replace fan motor wiring harness under parts warranty. **did not add refrigerant per clients request to save money for now**
St. Petersburg, FL 33703
1200sf home 

2.5T Straight Cool Goodman 

System is low on refrigerant indicating leak. Air handler coil has spotting. 

Further notes 
-indoor blower motor accumulating bacterial growth 
-outdoor capacitor rusted 
-outdoor coils impacted 
-attic above ideal temperature 

Ducting 
-main supply duct has holes in insulation 
-supply to kitchen and living room have tears in insulation 

Sending over estimate for repairs 

Went over system operations
1200sf home 

2.5T Straight Cool Goodman 

System is low on refrigerant indicating leak. Air handler coil has spotting. 

Further notes 
-indoor blower motor accumulating bacterial growth 
-outdoor capacitor rusted 
-outdoor coils impacted 
-attic above ideal temperature 

Ducting 
-main supply duct has holes in insulation 
-supply to kitchen and living room have tears in insulation 

Sending over estimate for repairs 

Went over system operations
Nathan A.
Nathan A. Checked in
1200sf home 2.5T Straight Cool Goodman System is low on refrigerant indicating leak. Air handler coil has spotting. Further notes -indoor blower motor accumulating bacterial growth -outdoor capacitor rusted -outdoor coils impacted -attic above ideal temperature Ducting -main supply duct has holes in insulation -supply to kitchen and living room have tears in insulation Sending over estimate for repairs Went over system operations
St. Petersburg, FL 33714
Review
Great service, came to my place the same day I called. Nate is a great communicator and technician; he kept me informed each step along the way. Nate and Griffin (the electrical technician) are honest, trustworthy, prompt, knowledgeable , and a pleasure to work with. Highly recommend!
Susan A. Valot - St. Petersburg, FL 33703
Response from Air Bros Air Conditioning & Electrical:

Thank you, Susan, for your wonderful 5-star rating; your support means a lot to us!

Review
I had an outstanding experience with Air Bros from the moment I scheduled my service through to the completion of the job. Nate arrived right on schedule and was incredibly professional from start to finish. He performed a thorough preventative maintenance and cleaning of our system with a high attention to detail. He took the time to check our entire system and went above and beyond to answer all my questions in detail about maintenance tips to help prevent future issues. Nate's expertise, friendly demeanor and professionalism along with the entire scheduling process were truly amazing!
Marci Gleicher - St. Petersburg, FL 33704
Response from Air Bros Air Conditioning & Electrical:

Thank you, Marci, for sharing your wonderful experience and recognizing Nate's professionalism and dedication; we truly appreciate your feedback and are glad to know our service met your expectations!

Review
Air Bros has been my go-to for HVAC since I bought my house in 2017, and I wouldnt trust anyone else! Ricky has kept my old unit running like a champ for years, and when my house recently flooded, Justin showed up to get it back up and runningbuying me some time before I finally replace it (after 20 years, its definitely earned its retirement!). Theyre always on time, know their stuff, and even a hit with my dogs. If you want honest, reliable, high-quality service in St. Pete, these guys are the way to go!
Amelia Johnson - St. Petersburg, FL 33704
Response from Air Bros Air Conditioning & Electrical:

Thank you, Amelia, for your kind words and for being a loyal customer since 2017! We're glad to hear that Ricky has kept your unit running smoothly and that Justin was there to help during a tough time. It means a lot to us to know we can provide reliable service for you and your furry friends!

Review
Nathan helped me out on very short notice, super professional and polite. Definitely will call again if need arises.
Ante Gotovina - St. Petersburg, FL 33704
Response from Air Bros Air Conditioning & Electrical:

Thank you, Ante, for your kind words about Nathan's professionalism and quick assistance; we look forward to helping you again in the future!

Contact the Bros You Know Today!

Schedule Service Online
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at 727-217-6148 .

By pressing Submit I agree to receive phone, email, or text messages from Air Bros Air Conditioning & Heating to the provided mobile number and also agree to the Air Bros Air Conditioning & Heating terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next