Instant Quote Shop Filters Call Air Bros

St. Petersburg, FL

air-bros-team-with-truck

The Best AC Repair in St. Petersburg, FL — From Technicians Your Neighbors Already Trust

When your AC quits in the middle of a St. Pete summer, you don't want a stranger in an unmarked van. You want a technician your neighbors already know and trust. Air Bros Air Conditioning & Electrical has been fixing air conditioners in St. Petersburg since 2020, but our roots run deeper — founder Ricky Orta grew up learning the trade from his father and has been a licensed HVAC contractor since 2006. That local, hands-on experience is why homeowners from Historic Kenwood to Snell Isle call us the best AC repair company in St. Petersburg.

We're headquartered right here in the Shore Acres neighborhood, so when you call, you're not routed to a call center — you're talking to the same local team that services your street.

Call us at 727-217-6148 or contact us online today for all of your HVAC, indoor air quality and electrical needs.

Meet the technicians who service St. Petersburg

What to expect when we show up

Calling a repair company you've never used before shouldn't feel like a gamble. Here's exactly how an Air Bros service call goes, every time.

You'll get a heads-up before we arrive, then a uniformed technician in a marked Air Bros vehicle shows up in the window we promised. We diagnose the whole system — not just the obvious symptom — then explain what we found and what your options are before any work starts. You approve the price up front, we make the repair, and we don't leave until we've confirmed the system is cooling the way it should.

Every technician is a background-checked, drug-tested Air Bros employee — never a subcontractor — and each one is trained to service every major AC and heat pump brand. It's the kind of consistency you can only get from a local team that answers to its own name.

And if something isn't right? Our 100% satisfaction guarantee means we make it right.

Signs you need AC repair

St. Petersburg's heat and humidity push air conditioners harder than almost anywhere else in the country. Call for AC repair if you notice:

  • Warm air blowing from vents, or the system running constantly without cooling
  • Water pooling around your air handler (a common issue in St. Pete's older homes with attic-run drain lines)
  • Musty odors or visible mold near vents — a sign of a clogged condensate line or dirty coil
  • Rising humidity indoors despite the AC running
  • Short cycling, tripped breakers, or a system that won't turn on at all

Our technicians diagnose the full system on every call — refrigerant charge, temperature split, electrical connections, and drain line — so you get a real fix, not a temporary patch.

Comprehensive HVAC Services in St. Petersburg

We offer a full range of heating and cooling services to keep your St. Petersburg, FL, home comfortable year-round:

  • Air Conditioning: From AC repair and AC installation to routine maintenance, we ensure your cooling system keeps you comfortable during those hot Florida summers. We offer same-day service for AC emergencies, so you never have to suffer in the heat.
  • Heating: Stay warm and cozy in the winter with our comprehensive heating services. We repair and install all types of heating systems, including furnaces and heat pumps, and offer preventative maintenance to keep your system running efficiently.
  • Indoor Air Quality: Improve your indoor air quality with our dehumidifier and UV light installation services. We'll help you control excess humidity and eliminate airborne contaminants, creating a healthier home environment.
  • Ductwork: Ensure optimal airflow and energy efficiency with our ductwork repair and installation services. We can address leaks and damage, and design a system that's perfect for your home.
  • Pool Heater Services: Extend your swim season with our pool heater installation and repair services.
  • Electrical Services: From outlet and switch replacements to ceiling fan installations to whole-house surge protector installations, we have the experts to handle your electrical service needs.

Our experienced technicians are skilled in all aspects of HVAC service and are dedicated to providing top-quality workmanship and customer care.

Why Choose Air Bros?

  • Local Expertise: We understand the unique climate challenges of St. Petersburg.
  • Fast and Reliable Service: We offer same-day service for AC emergencies and prioritize prompt service for all your HVAC needs.
  • Experienced Technicians: Our team is highly trained and experienced in all aspects of HVAC service.
  • Upfront Pricing: We provide transparent pricing with no hidden costs.
  • Customer Satisfaction Guaranteed: Your comfort and satisfaction are our top priorities.

Contact Air Bros Today!

Whether you need emergency AC repair, a new heating system installation, or any other HVAC service, Air Bros is here to help. Contact us today for a free consultation or to schedule a service appointment. We're proud to be your trusted HVAC partner in St. Petersburg!

Call us at 727-217-6148 or contact us online today!

Recent Jobs and Reviews in St. Petersburg, FL

St. Petersburg, FL at a glance

Air Bros Air Conditioning & Electrical has completed 25 jobs in St. Petersburg, FL in October 2026.

The 4 customer reviews shown here average 5.0 out of 5.

The most recent job was on October 19, 2026.

Air Bros Air Conditioning & Electrical has completed 1,869 jobs in St. Petersburg, FL in the last 12 months. The first job there was in December 2024.

Job Locations and Reviews

Reason for call:
No cool 

Summary:
Found unit frozen over on arrival. 
Found mismatch equipment.
2015 Condneser 
2022 air handler 
Found failed blower motor 
Had 24v at blower plug to tell unit to turn on 
Had 240v at blower plug to supply motor with power
Confirmed parts warranty on air handler unit 2027 

Homeowner wanted second opinion. 

See photos for proof 

Solution:
Quoted level 1 warranty motor replacement 

Left breaker off and motor unplugged to prevent further damage to equipment
Reason for call:
No cool 

Summary:
Found unit frozen over on arrival. 
Found mismatch equipment.
2015 Condneser 
2022 air handler 
Found failed blower motor 
Had 24v at blower plug to tell unit to turn on 
Had 240v at blower plug to supply motor with power
Confirmed parts warranty on air handler unit 2027 

Homeowner wanted second opinion. 

See photos for proof 

Solution:
Quoted level 1 warranty motor replacement 

Left breaker off and motor unplugged to prevent further damage to equipment
Corbin C.
Corbin C. Checked in
Reason for call: No cool Summary: Found unit frozen over on arrival. Found mismatch equipment. 2015 Condneser 2022 air handler Found failed blower motor Had 24v at blower plug to tell unit to turn on Had 240v at blower plug to supply motor with power Confirmed parts warranty on air handler unit 2027 Homeowner wanted second opinion. See photos for proof Solution: Quoted level 1 warranty motor replacement Left breaker off and motor unplugged to prevent further damage to equipment
St. Petersburg, FL 33710
St. Petersburg, FL - Replace blower motor for upstairs unit. Tax and labor included.
Justin G.
Justin G. Checked in
Replace blower motor for upstairs unit. Tax and labor included.
St. Petersburg, FL 33710
2021 Grand Aire 

2.5T 1200sf home 

Diagnostic 
-failed air handler blower motor 
-system freezing over 

Further Notes 
-blower wheel impacted with bacterial growth 
-air handler cabinet/wiring impacted with bacterial growth 
-air handler door insulation being sucked into air handler housing 

Scope of work
-pickup/install warranty blower motor 
-sanitize air handler interior housing/wiring 
-sanitize blower wheel/assembly
-install single bulb air purifier 
-spray glue/tape insulation back to air handler door 

After completing repairs and letting system run. Found delta of 15° and unit operating at 2.7sc indicating system low on refrigerant. 

Charged system to 20° delta (cooler weather outside)

Explained system could potentially have a leak and if low again we will need to do a leak search 

Unit is currently operating within manufacture specifications 

Home owner would like to schedule duct inspection (bedroom/bathroom area hotter areas)
2021 Grand Aire 

2.5T 1200sf home 

Diagnostic 
-failed air handler blower motor 
-system freezing over 

Further Notes 
-blower wheel impacted with bacterial growth 
-air handler cabinet/wiring impacted with bacterial growth 
-air handler door insulation being sucked into air handler housing 

Scope of work
-pickup/install warranty blower motor 
-sanitize air handler interior housing/wiring 
-sanitize blower wheel/assembly
-install single bulb air purifier 
-spray glue/tape insulation back to air handler door 

After completing repairs and letting system run. Found delta of 15° and unit operating at 2.7sc indicating system low on refrigerant. 

Charged system to 20° delta (cooler weather outside)

Explained system could potentially have a leak and if low again we will need to do a leak search 

Unit is currently operating within manufacture specifications 

Home owner would like to schedule duct inspection (bedroom/bathroom area hotter areas)
Nathan A.
Nathan A. Checked in
2021 Grand Aire 2.5T 1200sf home Diagnostic -failed air handler blower motor -system freezing over Further Notes -blower wheel impacted with bacterial growth -air handler cabinet/wiring impacted with bacterial growth -air handler door insulation being sucked into air handler housing Scope of work -pickup/install warranty blower motor -sanitize air handler interior housing/wiring -sanitize blower wheel/assembly -install single bulb air purifier -spray glue/tape insulation back to air handler door After completing repairs and letting system run. Found delta of 15° and unit operating at 2.7sc indicating system low on refrigerant. Charged system to 20° delta (cooler weather outside) Explained system could potentially have a leak and if low again we will need to do a leak search Unit is currently operating within manufacture specifications Home owner would like to schedule duct inspection (bedroom/bathroom area hotter areas)
St. Petersburg, FL 33703
Upon arrival, I began by checking the temperature split between the supply and return air while the system was operating in cooling mode. The system produced an 18°F temperature split, indicating normal cooling performance. I also tested the system in heating mode, and the system was operating properly with no issues observed.

I then inspected the electrical components and found all equipment operating within manufacturer specifications, with no components exceeding their rated amperage. The refrigerant cycle was also checked and is operating properly with no issues observed at this time.

As part of today’s maintenance, I performed a complete condensate drain line treatment, cleaned the drain pan, cleaned the outdoor condenser coil, and completed a full air handler inspection. The system is operating properly at this time.

If you have any questions or concerns, please don’t hesitate to reach out. Thank you for your business, and have a great day.
Upon arrival, I began by checking the temperature split between the supply and return air while the system was operating in cooling mode. The system produced an 18°F temperature split, indicating normal cooling performance. I also tested the system in heating mode, and the system was operating properly with no issues observed.

I then inspected the electrical components and found all equipment operating within manufacturer specifications, with no components exceeding their rated amperage. The refrigerant cycle was also checked and is operating properly with no issues observed at this time.

As part of today’s maintenance, I performed a complete condensate drain line treatment, cleaned the drain pan, cleaned the outdoor condenser coil, and completed a full air handler inspection. The system is operating properly at this time.

If you have any questions or concerns, please don’t hesitate to reach out. Thank you for your business, and have a great day.
ihsan m.
ihsan m. Checked in
Upon arrival, I began by checking the temperature split between the supply and return air while the system was operating in cooling mode. The system produced an 18°F temperature split, indicating normal cooling performance. I also tested the system in heating mode, and the system was operating properly with no issues observed. I then inspected the electrical components and found all equipment operating within manufacturer specifications, with no components exceeding their rated amperage. The refrigerant cycle was also checked and is operating properly with no issues observed at this time. As part of today’s maintenance, I performed a complete condensate drain line treatment, cleaned the drain pan, cleaned the outdoor condenser coil, and completed a full air handler inspection. The system is operating properly at this time. If you have any questions or concerns, please don’t hesitate to reach out. Thank you for your business, and have a great day.
St. Petersburg, FL 33703
Run a new dedicated circuit to the microwave install 2 new breakers in the panel disconnect existing microwave circuit 

Very
Run a new dedicated circuit to the microwave install 2 new breakers in the panel disconnect existing microwave circuit 

Very
Griffin K.
Griffin K. Checked in
Run a new dedicated circuit to the microwave install 2 new breakers in the panel disconnect existing microwave circuit Very
St. Petersburg, FL 33703
Reason for call:
Member tune up 

Summary:
Confirmed proper temperature.
Confirmed proper amp draws.
Confirmed proper capacitor readings.
Cleaned indoor coils. 
Flushed drain line.
Changed filter.
There is good filter stock now we will not need to bring filters for a year. 


Solution:
No issues presented themselves at this time. 

Charged 90 dollars on today's visit for supply of filters.
Reason for call:
Member tune up 

Summary:
Confirmed proper temperature.
Confirmed proper amp draws.
Confirmed proper capacitor readings.
Cleaned indoor coils. 
Flushed drain line.
Changed filter.
There is good filter stock now we will not need to bring filters for a year. 


Solution:
No issues presented themselves at this time. 

Charged 90 dollars on today's visit for supply of filters.
Corbin C.
Corbin C. Checked in
Reason for call: Member tune up Summary: Confirmed proper temperature. Confirmed proper amp draws. Confirmed proper capacitor readings. Cleaned indoor coils. Flushed drain line. Changed filter. There is good filter stock now we will not need to bring filters for a year. Solution: No issues presented themselves at this time. Charged 90 dollars on today's visit for supply of filters.
St. Petersburg, FL 33701
Replace warranty evaporator coil for mini split head
Replace warranty evaporator coil for mini split head
Ricky O.
Ricky O. Checked in
Replace warranty evaporator coil for mini split head
St. Petersburg, FL 33704
St. Petersburg, FL - On arrival found upstairs unit not cooling due to bad blower motor. Will return to replace motor.
Justin G.
Justin G. Checked in
On arrival found upstairs unit not cooling due to bad blower motor. Will return to replace motor.
St. Petersburg, FL 33710
Michael A.
Michael A. Checked in
System not cooling properly due to a bad capacitor. Contactar is also pitted and has bad arc marks. Recommended preventive replacement. Replaced capacitor and contactar and started system. System is cooling with good temperature split and amp draws. Condenser is an older champion system. Air handler is newer Trane system. Mix matched. Client is aware that we cannot just replace the condenser if needed due to new refrigerant laws and inaccessibility to older systems.
St. Petersburg, FL 33702
2.5 Ton 15 SEER Heat Pump 2 stage cooling RUUD system 
~ 10 Year parts warranty  
~ 3 year Labor warranty
- $9025 cash/check price
______
- Installation of vertical air handler in closet
- New Insulated return stand
- Seal supply plenum to unit
- Reposition air handler disconnect (bring 3/4” Clad to extend if necessary)
- 5kw back up heat element
- New WIFI thermostat
- New safety float switch
- New insulation on copper
- Replace breakers as needed
- Flush and test existing condensate drain line
______
- Installation of Condenser unit 
- Flush existing refrigerant lines
- Replace breakers as needed
- New 4” hurricane concrete pad
- New Hurricane straps 
- New UV rated insulation on copper
- New filter line dryer
- Refrigerant locking caps
- Vacuum system to 500 microns
- Charge system with refrigerant to proper pressures

- Completed to code
100% satisfaction
2.5 Ton 15 SEER Heat Pump 2 stage cooling RUUD system 
~ 10 Year parts warranty  
~ 3 year Labor warranty
- $9025 cash/check price
______
- Installation of vertical air handler in closet
- New Insulated return stand
- Seal supply plenum to unit
- Reposition air handler disconnect (bring 3/4” Clad to extend if necessary)
- 5kw back up heat element
- New WIFI thermostat
- New safety float switch
- New insulation on copper
- Replace breakers as needed
- Flush and test existing condensate drain line
______
- Installation of Condenser unit 
- Flush existing refrigerant lines
- Replace breakers as needed
- New 4” hurricane concrete pad
- New Hurricane straps 
- New UV rated insulation on copper
- New filter line dryer
- Refrigerant locking caps
- Vacuum system to 500 microns
- Charge system with refrigerant to proper pressures

- Completed to code
100% satisfaction
Ricky O.
Ricky O. Checked in
2.5 Ton 15 SEER Heat Pump 2 stage cooling RUUD system ~ 10 Year parts warranty ~ 3 year Labor warranty - $9025 cash/check price ______ - Installation of vertical air handler in closet - New Insulated return stand - Seal supply plenum to unit - Reposition air handler disconnect (bring 3/4” Clad to extend if necessary) - 5kw back up heat element - New WIFI thermostat - New safety float switch - New insulation on copper - Replace breakers as needed - Flush and test existing condensate drain line ______ - Installation of Condenser unit - Flush existing refrigerant lines - Replace breakers as needed - New 4” hurricane concrete pad - New Hurricane straps - New UV rated insulation on copper - New filter line dryer - Refrigerant locking caps - Vacuum system to 500 microns - Charge system with refrigerant to proper pressures - Completed to code 100% satisfaction
St. Petersburg, FL 33707
System not cooling due to full secondary emergency pan and clogged drain. Primary float has failed. 
Performed a drain cleaning on system and installation of new primary float switch. 
Had to cut drain line within closet to hook up shop vac. Drain line is disconnected under home. 
System cooling and draining at this time. 
New drain line recommended. Went over previous estimate with client. 

Found indoor blower wheel extremely dirty. Recommended a blower pull and clean. 

Recommended maitenence plan. 

Filters are extremely dirty and need to be replaced today. Let client know. 

Filter sizes 12x24 and 12x12
System not cooling due to full secondary emergency pan and clogged drain. Primary float has failed. 
Performed a drain cleaning on system and installation of new primary float switch. 
Had to cut drain line within closet to hook up shop vac. Drain line is disconnected under home. 
System cooling and draining at this time. 
New drain line recommended. Went over previous estimate with client. 

Found indoor blower wheel extremely dirty. Recommended a blower pull and clean. 

Recommended maitenence plan. 

Filters are extremely dirty and need to be replaced today. Let client know. 

Filter sizes 12x24 and 12x12
Michael A.
Michael A. Checked in
System not cooling due to full secondary emergency pan and clogged drain. Primary float has failed. Performed a drain cleaning on system and installation of new primary float switch. Had to cut drain line within closet to hook up shop vac. Drain line is disconnected under home. System cooling and draining at this time. New drain line recommended. Went over previous estimate with client. Found indoor blower wheel extremely dirty. Recommended a blower pull and clean. Recommended maitenence plan. Filters are extremely dirty and need to be replaced today. Let client know. Filter sizes 12x24 and 12x12
St. Petersburg, FL 33713
Found bedroom system dripping water due to severely rusted out unit and the secondary pan that was installed has rusted through at the metal connection to PVC. 
System is in very poor condition due to rust and at risk of severe irreversible damage if attempted to service. We cannot source parts for these systems. 
Recommending system replacement due to condition of unit. 
Quote sent for replacement. 
Installs are typically atleast 1 week out due to shipping time. 

Inspected living room system and found that system is not as rusted and needs a primary pan removal/cleaning as it is condensating and the primary pan has standing water. Client accepted quote for cleanings and we will schedule the following week. 

Current tenants are leaving Tuesday but we can access the unit with maitenence crew.
Found bedroom system dripping water due to severely rusted out unit and the secondary pan that was installed has rusted through at the metal connection to PVC. 
System is in very poor condition due to rust and at risk of severe irreversible damage if attempted to service. We cannot source parts for these systems. 
Recommending system replacement due to condition of unit. 
Quote sent for replacement. 
Installs are typically atleast 1 week out due to shipping time. 

Inspected living room system and found that system is not as rusted and needs a primary pan removal/cleaning as it is condensating and the primary pan has standing water. Client accepted quote for cleanings and we will schedule the following week. 

Current tenants are leaving Tuesday but we can access the unit with maitenence crew.
Michael A.
Michael A. Checked in
Found bedroom system dripping water due to severely rusted out unit and the secondary pan that was installed has rusted through at the metal connection to PVC. System is in very poor condition due to rust and at risk of severe irreversible damage if attempted to service. We cannot source parts for these systems. Recommending system replacement due to condition of unit. Quote sent for replacement. Installs are typically atleast 1 week out due to shipping time. Inspected living room system and found that system is not as rusted and needs a primary pan removal/cleaning as it is condensating and the primary pan has standing water. Client accepted quote for cleanings and we will schedule the following week. Current tenants are leaving Tuesday but we can access the unit with maitenence crew.
St. Petersburg, FL 33701
System not cooling due to severely clogged drain and full secondary emergency pan. 
Performed lvl 3 drain cleaning and treatment. 
Started system and found primary float switch not working. 
Replaced float switch. 
System is now cooling and draining. 
Office will schedule first maitenence with client. 
Client needs to change filter
System not cooling due to severely clogged drain and full secondary emergency pan. 
Performed lvl 3 drain cleaning and treatment. 
Started system and found primary float switch not working. 
Replaced float switch. 
System is now cooling and draining. 
Office will schedule first maitenence with client. 
Client needs to change filter
Michael A.
Michael A. Checked in
System not cooling due to severely clogged drain and full secondary emergency pan. Performed lvl 3 drain cleaning and treatment. Started system and found primary float switch not working. Replaced float switch. System is now cooling and draining. Office will schedule first maitenence with client. Client needs to change filter
St. Petersburg, FL 33702
Upon arrival, the homeowner stated that he had attempted to clear the drain line by sucking on it because he suspected it was clogged. Initially, refrigerant pressures were fluctuating significantly, and the compressor appeared to be overheating. I inspected the drain safety switch and found a small amount of water inside, which may have been contributing to intermittent system shutdowns.

I allowed the system to operate for approximately 30 minutes to monitor its performance. During this time, the system stabilized, refrigerant pressures remained within normal operating ranges, and the system maintained an 18°F temperature split. No further issues were observed during the monitoring period.

If you have any questions or concerns, please feel free to reach out. Thank you for your business, and have a great day!

Please note, I told the homeowner today is $150 charge but if we have to come back and re-diagnose with a different issue like the compressor failing that will apply a discount
Upon arrival, the homeowner stated that he had attempted to clear the drain line by sucking on it because he suspected it was clogged. Initially, refrigerant pressures were fluctuating significantly, and the compressor appeared to be overheating. I inspected the drain safety switch and found a small amount of water inside, which may have been contributing to intermittent system shutdowns.

I allowed the system to operate for approximately 30 minutes to monitor its performance. During this time, the system stabilized, refrigerant pressures remained within normal operating ranges, and the system maintained an 18°F temperature split. No further issues were observed during the monitoring period.

If you have any questions or concerns, please feel free to reach out. Thank you for your business, and have a great day!

Please note, I told the homeowner today is $150 charge but if we have to come back and re-diagnose with a different issue like the compressor failing that will apply a discount
ihsan m.
ihsan m. Checked in
Upon arrival, the homeowner stated that he had attempted to clear the drain line by sucking on it because he suspected it was clogged. Initially, refrigerant pressures were fluctuating significantly, and the compressor appeared to be overheating. I inspected the drain safety switch and found a small amount of water inside, which may have been contributing to intermittent system shutdowns. I allowed the system to operate for approximately 30 minutes to monitor its performance. During this time, the system stabilized, refrigerant pressures remained within normal operating ranges, and the system maintained an 18°F temperature split. No further issues were observed during the monitoring period. If you have any questions or concerns, please feel free to reach out. Thank you for your business, and have a great day! Please note, I told the homeowner today is $150 charge but if we have to come back and re-diagnose with a different issue like the compressor failing that will apply a discount
St. Petersburg, FL 33703
Kyle K.
Kyle K. Checked in
Replace plenum Redo duct work connections Seal plenum to equipment Reconnect case coil to the furnace Left portions of the drain line unglued so you don't have to re-do it. Please connect.
St. Petersburg, FL 33702
Inspected home for high humidity. Found thermostat was reading temp and humidity incorrectly. Adjusted thermostat to read properly. Filled unit with proper amount of refrigerant. Unit has 20* split. Pressures good. Unit cooling properly.
Inspected home for high humidity. Found thermostat was reading temp and humidity incorrectly. Adjusted thermostat to read properly. Filled unit with proper amount of refrigerant. Unit has 20* split. Pressures good. Unit cooling properly.
Justin G.
Justin G. Checked in
Inspected home for high humidity. Found thermostat was reading temp and humidity incorrectly. Adjusted thermostat to read properly. Filled unit with proper amount of refrigerant. Unit has 20* split. Pressures good. Unit cooling properly.
St. Petersburg, FL 33716
Bard Unit 

Service Panel 6” from wall 

Tuneup 

Home owner concerned with water leaking out of unit 

Diagnostic 
-drain line terminates through wall and backing causing drain pan to hold water 

Cleared drain line and drain pan 

Lightly rinsed indoor coils 

Inspected fan motors (2)

Tested fan cap mfd

Removed double filter 

Thermosat operations 

Temp split still holding at 18° from previous visit (77 indoor ambient at return) (filled system due to being low on refrigerant/leak)

Unit is currently operating
Bard Unit 

Service Panel 6” from wall 

Tuneup 

Home owner concerned with water leaking out of unit 

Diagnostic 
-drain line terminates through wall and backing causing drain pan to hold water 

Cleared drain line and drain pan 

Lightly rinsed indoor coils 

Inspected fan motors (2)

Tested fan cap mfd

Removed double filter 

Thermosat operations 

Temp split still holding at 18° from previous visit (77 indoor ambient at return) (filled system due to being low on refrigerant/leak)

Unit is currently operating
Nathan A.
Nathan A. Checked in
Bard Unit Service Panel 6” from wall Tuneup Home owner concerned with water leaking out of unit Diagnostic -drain line terminates through wall and backing causing drain pan to hold water Cleared drain line and drain pan Lightly rinsed indoor coils Inspected fan motors (2) Tested fan cap mfd Removed double filter Thermosat operations Temp split still holding at 18° from previous visit (77 indoor ambient at return) (filled system due to being low on refrigerant/leak) Unit is currently operating
St. Petersburg, FL 33702
Run new sleeve for exposed electrical wire next to condenser. Tax and labor included.
Run new sleeve for exposed electrical wire next to condenser. Tax and labor included.
Griffin K.
Griffin K. Checked in
Run new sleeve for exposed electrical wire next to condenser. Tax and labor included.
St. Petersburg, FL 33702
Found system
Not cooling due to bad cap. I went over options with client for repair vs replace and let him know system is old and in poor condition. Client chose repair for now.
Found system
Not cooling due to bad cap. I went over options with client for repair vs replace and let him know system is old and in poor condition. Client chose repair for now.
Ricky O.
Ricky O. Checked in
Found system Not cooling due to bad cap. I went over options with client for repair vs replace and let him know system is old and in poor condition. Client chose repair for now.
St. Petersburg, FL 33705
System not cooling due to clogged drain line. 
Cleaned drain line and started system. 
Found many deficiencies within the system. 
System is mix matched and very old. 
Sent quote for full replacement.
System not cooling due to clogged drain line. 
Cleaned drain line and started system. 
Found many deficiencies within the system. 
System is mix matched and very old. 
Sent quote for full replacement.
Michael A.
Michael A. Checked in
System not cooling due to clogged drain line. Cleaned drain line and started system. Found many deficiencies within the system. System is mix matched and very old. Sent quote for full replacement.
St. Petersburg, FL 33716
Justin G.
Justin G. Checked in
Replace blower motor and board. Tax and labor included. Unit cooling with 20* split.
St. Petersburg, FL 33704
On arrival found bedroom unit with leaking evaporator coil. Unable to provide repair option for system due to location and severity of leak. Will submit estimate for system replacement.
On arrival found bedroom unit with leaking evaporator coil. Unable to provide repair option for system due to location and severity of leak. Will submit estimate for system replacement.
Justin G.
Justin G. Checked in
On arrival found bedroom unit with leaking evaporator coil. Unable to provide repair option for system due to location and severity of leak. Will submit estimate for system replacement.
St. Petersburg, FL 33701
Downstairs GOODMAN Split System (1st & Second Floor)

Diagnostic 
-failed outdoor capacitor causing system not to operate 
-heavily pitted and rusted contactor 

Went over repair options with home owner 

Scope of work 
-replace and wire capacitor 
-replace and wire contactor 

Tested and inspected upstairs unit contactor and capacitor (both reading within manufacture specifications and recently replaced)

Verified system operations after completing repairs
Downstairs GOODMAN Split System (1st & Second Floor)

Diagnostic 
-failed outdoor capacitor causing system not to operate 
-heavily pitted and rusted contactor 

Went over repair options with home owner 

Scope of work 
-replace and wire capacitor 
-replace and wire contactor 

Tested and inspected upstairs unit contactor and capacitor (both reading within manufacture specifications and recently replaced)

Verified system operations after completing repairs
Nathan A.
Nathan A. Checked in
Downstairs GOODMAN Split System (1st & Second Floor) Diagnostic -failed outdoor capacitor causing system not to operate -heavily pitted and rusted contactor Went over repair options with home owner Scope of work -replace and wire capacitor -replace and wire contactor Tested and inspected upstairs unit contactor and capacitor (both reading within manufacture specifications and recently replaced) Verified system operations after completing repairs
St. Petersburg, FL 33712
Install 120v safety switch. Clean and sanitize air handler from fire damage. Tax and labor included.
Client still dissatisfied with smell. Wants pan replaced. Will let Jeff know.
Install 120v safety switch. Clean and sanitize air handler from fire damage. Tax and labor included.
Client still dissatisfied with smell. Wants pan replaced. Will let Jeff know.
Justin G.
Justin G. Checked in
Install 120v safety switch. Clean and sanitize air handler from fire damage. Tax and labor included. Client still dissatisfied with smell. Wants pan replaced. Will let Jeff know.
St. Petersburg, FL 33701
Full System Tuneup 

Home owner concerned with burning electrical smell intermittently 

Home owner concerned about outdoor unit being loud 

Home owner concerned about more dust/debris in home 

System & Ducting Installed by Airbros 



Electrical Concern 
-verified high voltage wiring not pitted/charred 
-tightened down high voltage connections 
-pulled blower amps (within specs)
-verified motor not overheating 

Loud Outdoor Unit Concern 
-outdoor motor amps within manufacture specifications 
-outdoor compressor amps within manufacture specifications 
-start up amps within manufacture specifications 
-tightened down screws & hardware 
-recommend installing soft start 

Dust Concern 
-ducting from attic to bottom floor not replaced due to having to remove ceilings/walls
-recommend better filtration
-blower wheel has no signs of bacteria/debris 
-recommend calling DUCTZ for inspection 
-verified attic ducts/plenums sealed properly 

Unit is operating within manufacture specifications
Full System Tuneup 

Home owner concerned with burning electrical smell intermittently 

Home owner concerned about outdoor unit being loud 

Home owner concerned about more dust/debris in home 

System & Ducting Installed by Airbros 



Electrical Concern 
-verified high voltage wiring not pitted/charred 
-tightened down high voltage connections 
-pulled blower amps (within specs)
-verified motor not overheating 

Loud Outdoor Unit Concern 
-outdoor motor amps within manufacture specifications 
-outdoor compressor amps within manufacture specifications 
-start up amps within manufacture specifications 
-tightened down screws & hardware 
-recommend installing soft start 

Dust Concern 
-ducting from attic to bottom floor not replaced due to having to remove ceilings/walls
-recommend better filtration
-blower wheel has no signs of bacteria/debris 
-recommend calling DUCTZ for inspection 
-verified attic ducts/plenums sealed properly 

Unit is operating within manufacture specifications
Nathan A.
Nathan A. Checked in
Full System Tuneup Home owner concerned with burning electrical smell intermittently Home owner concerned about outdoor unit being loud Home owner concerned about more dust/debris in home System & Ducting Installed by Airbros Electrical Concern -verified high voltage wiring not pitted/charred -tightened down high voltage connections -pulled blower amps (within specs) -verified motor not overheating Loud Outdoor Unit Concern -outdoor motor amps within manufacture specifications -outdoor compressor amps within manufacture specifications -start up amps within manufacture specifications -tightened down screws & hardware -recommend installing soft start Dust Concern -ducting from attic to bottom floor not replaced due to having to remove ceilings/walls -recommend better filtration -blower wheel has no signs of bacteria/debris -recommend calling DUCTZ for inspection -verified attic ducts/plenums sealed properly Unit is operating within manufacture specifications
St. Petersburg, FL 33705
Review
Great service, came to my place the same day I called. Nate is a great communicator and technician; he kept me informed each step along the way. Nate and Griffin (the electrical technician) are honest, trustworthy, prompt, knowledgeable , and a pleasure to work with. Highly recommend!
Susan A. Valot - St. Petersburg, FL 33703
Response from Air Bros Air Conditioning & Electrical:

Thank you, Susan, for your wonderful 5-star rating; your support means a lot to us!

Review
I had an outstanding experience with Air Bros from the moment I scheduled my service through to the completion of the job. Nate arrived right on schedule and was incredibly professional from start to finish. He performed a thorough preventative maintenance and cleaning of our system with a high attention to detail. He took the time to check our entire system and went above and beyond to answer all my questions in detail about maintenance tips to help prevent future issues. Nate's expertise, friendly demeanor and professionalism along with the entire scheduling process were truly amazing!
Marci Gleicher - St. Petersburg, FL 33704
Response from Air Bros Air Conditioning & Electrical:

Thank you, Marci, for sharing your wonderful experience and recognizing Nate's professionalism and dedication; we truly appreciate your feedback and are glad to know our service met your expectations!

Review
Air Bros has been my go-to for HVAC since I bought my house in 2017, and I wouldnt trust anyone else! Ricky has kept my old unit running like a champ for years, and when my house recently flooded, Justin showed up to get it back up and runningbuying me some time before I finally replace it (after 20 years, its definitely earned its retirement!). Theyre always on time, know their stuff, and even a hit with my dogs. If you want honest, reliable, high-quality service in St. Pete, these guys are the way to go!
Amelia Johnson - St. Petersburg, FL 33704
Response from Air Bros Air Conditioning & Electrical:

Thank you, Amelia, for your kind words and for being a loyal customer since 2017! We're glad to hear that Ricky has kept your unit running smoothly and that Justin was there to help during a tough time. It means a lot to us to know we can provide reliable service for you and your furry friends!

Review
Nathan helped me out on very short notice, super professional and polite. Definitely will call again if need arises.
Ante Gotovina - St. Petersburg, FL 33704
Response from Air Bros Air Conditioning & Electrical:

Thank you, Ante, for your kind words about Nathan's professionalism and quick assistance; we look forward to helping you again in the future!

How do I know if my AC needs repair or full replacement?

Our technicians inspect the full system — age, refrigerant type, corrosion, and repair history — and give you an honest recommendation. If a repair makes sense, we'll fix it. If the unit is beyond its useful life, we'll walk you through replacement options with no pressure.

Are your technicians background-checked and licensed?

Yes. Every Air Bros technician is background-checked, factory-trained, and works under our state HVAC license (#CAC1820499) and electrical license (#EC13015085).

What parts of St. Petersburg do you serve?

We serve all of St. Petersburg, including Downtown, Historic Kenwood, Old Northeast, Snell Isle, Crescent Lake, Shore Acres, and Coquina Key, plus Seminole, Largo, Pinellas Park, and the surrounding beach communities.

Do you offer same-day AC repair in St. Petersburg?

Yes. We offer 24/7 emergency AC repair with same-day service throughout St. Petersburg and the surrounding Pinellas County area.

Is Air Bros a local St. Petersburg company, or a franchise?

Air Bros is 100% locally owned and operated, headquartered in the Shore Acres neighborhood of St. Petersburg. We're not a franchise — every technician is a direct employee, not a subcontractor.

Contact the Bros You Know Today!

Gravity Forms Pagination Must be Steps