Instant Quote Shop Filters Call Air Bros Book Service

St. Petersburg, FL

air-bros-team-with-truck

Your St. Petersburg, FL HVAC Experts

Air Bros Air Conditioning & Heating is proud to serve the vibrant community of St. Petersburg, FL. We understand the unique challenges that St. Petersburg homeowners and businesses face when it comes to maintaining comfortable indoor temperatures year-round. Our team of experienced and certified technicians is dedicated to providing top-quality HVAC services tailored to the specific needs of our St. Petersburg customers.

Call us at 727-217-6148 or contact us online today for all of your HVAC, indoor air quality and electrical needs.

Comprehensive HVAC Services in St. Petersburg

We offer a full range of heating and cooling services to keep your St. Petersburg, FL, home comfortable year-round:

  • Air Conditioning: From AC repair and AC installation to routine maintenance, we ensure your cooling system keeps you comfortable during those hot Florida summers. We offer same-day service for AC emergencies, so you never have to suffer in the heat.
  • Heating: Stay warm and cozy in the winter with our comprehensive heating services. We repair and install all types of heating systems, including furnaces and heat pumps, and offer preventative maintenance to keep your system running efficiently.
  • Indoor Air Quality: Improve your indoor air quality with our dehumidifier and UV light installation services. We'll help you control excess humidity and eliminate airborne contaminants, creating a healthier home environment.
  • Ductwork: Ensure optimal airflow and energy efficiency with our ductwork repair and installation services. We can address leaks and damage, and design a system that's perfect for your home.
  • Pool Heater Services: Extend your swim season with our pool heater installation and repair services.
  • Electrical Services: From outlet and switch replacements to ceiling fan installations to whole-house surge protector installations, we have the experts to handle your electrical service needs.

Our experienced technicians are skilled in all aspects of HVAC service and are dedicated to providing top-quality workmanship and customer care.

Why Choose Air Bros?

  • Local Expertise: We understand the unique climate challenges of St. Petersburg.
  • Fast and Reliable Service: We offer same-day service for AC emergencies and prioritize prompt service for all your HVAC needs.
  • Experienced Technicians: Our team is highly trained and experienced in all aspects of HVAC service.
  • Upfront Pricing: We provide transparent pricing with no hidden costs.
  • Customer Satisfaction Guaranteed: Your comfort and satisfaction are our top priorities.

Contact Air Bros Today!

Whether you need emergency AC repair, a new heating system installation, or any other HVAC service, Air Bros is here to help. Contact us today for a free consultation or to schedule a service appointment. We're proud to be your trusted HVAC partner in St. Petersburg!

Call us at 727-217-6148 or contact us online today!

Our St. Petersburg Location

Address: 1579 Delaware Ave NESt. Petersburg, FL 33703

Phone: 727-217-6148

Count on perfect service; Trust the bros you know!

Recent Jobs and Reviews in St. Petersburg, FL

Job Locations and Reviews

replace warranty evaporator coil, recharge with 2lbs R410A.
Completed repair confirmed proper pressure and a 20 degree temperature split. Unit is cooling well at this time. 

Added uv treatment kit
replace warranty evaporator coil, recharge with 2lbs R410A.
Completed repair confirmed proper pressure and a 20 degree temperature split. Unit is cooling well at this time. 

Added uv treatment kit
Corbin C.
Corbin C. Checked in
replace warranty evaporator coil, recharge with 2lbs R410A. Completed repair confirmed proper pressure and a 20 degree temperature split. Unit is cooling well at this time. Added uv treatment kit
St. Petersburg, FL 33713
Upon my inspection? Found bad capacitor and burnt wire. 
Replaced turbo 200x capacitor with 5 year warranty on the part. 
System is operating now with good amp draws on the compressor and fan motor. 
System is cooling with a 18° temperature split.
Upon my inspection? Found bad capacitor and burnt wire. 
Replaced turbo 200x capacitor with 5 year warranty on the part. 
System is operating now with good amp draws on the compressor and fan motor. 
System is cooling with a 18° temperature split.
Michael A.
Michael A. Checked in
Upon my inspection? Found bad capacitor and burnt wire. Replaced turbo 200x capacitor with 5 year warranty on the part. System is operating now with good amp draws on the compressor and fan motor. System is cooling with a 18° temperature split.
St. Petersburg, FL 33705
Drain line backing up on rooftop package unit.
Cleared drain line and drain pan. 

Went over adding mini splits to home as well
Drain line backing up on rooftop package unit.
Cleared drain line and drain pan. 

Went over adding mini splits to home as well
Nathan A.
Nathan A. Checked in
Drain line backing up on rooftop package unit. Cleared drain line and drain pan. Went over adding mini splits to home as well
St. Petersburg, FL 33702
Justin G.
Justin G. Checked in
On arrival found bad breaker due to blown transformer. Replaced breaker. Start and test. Unit cooling properly at this time.
St. Petersburg, FL 33710
Full tuneup on mini split
Full tuneup on mini split
Nathan A.
Nathan A. Checked in
Full tuneup on mini split
St. Petersburg, FL 33714
On arrival found blower motor not turning on in a timely manner when thermostat calls for cooling. Inspected unit and found blower is intermittently failing and will soon fail completely. Unit is 20 year old r22 in poor condition. Discussed with client repair and replacement options. We recommend to replace system due to age and condition. Unit has 15* temp split across coil. Unit is cooling to the best of its ability.
On arrival found blower motor not turning on in a timely manner when thermostat calls for cooling. Inspected unit and found blower is intermittently failing and will soon fail completely. Unit is 20 year old r22 in poor condition. Discussed with client repair and replacement options. We recommend to replace system due to age and condition. Unit has 15* temp split across coil. Unit is cooling to the best of its ability.
Justin G.
Justin G. Checked in
On arrival found blower motor not turning on in a timely manner when thermostat calls for cooling. Inspected unit and found blower is intermittently failing and will soon fail completely. Unit is 20 year old r22 in poor condition. Discussed with client repair and replacement options. We recommend to replace system due to age and condition. Unit has 15* temp split across coil. Unit is cooling to the best of its ability.
St. Petersburg, FL 33704
System freezing over due to impacted air handler coils. Coils are 10 years of age. Explained that cleaning coils on a system this age has potential danger of leaking. Recommend replacing air handler coils for guaranteed fix. Went over potential repair cost vs replacement cost.
System freezing over due to impacted air handler coils. Coils are 10 years of age. Explained that cleaning coils on a system this age has potential danger of leaking. Recommend replacing air handler coils for guaranteed fix. Went over potential repair cost vs replacement cost.
Nathan A.
Nathan A. Checked in
System freezing over due to impacted air handler coils. Coils are 10 years of age. Explained that cleaning coils on a system this age has potential danger of leaking. Recommend replacing air handler coils for guaranteed fix. Went over potential repair cost vs replacement cost.
St. Petersburg, FL 33702
Performed maintenance on 2 systems. Cleared pans and drains. Rinsed condenser coils. Filters clean. Electrical checked good. Pressures good. Temp split good. Both units cooling at this time. Found upstairs unit have heavy condensation around unit due to lack of circulation and high humidity. Recommend to add dehumidifier to space to prevent sweating and further moisture issues.
Performed maintenance on 2 systems. Cleared pans and drains. Rinsed condenser coils. Filters clean. Electrical checked good. Pressures good. Temp split good. Both units cooling at this time. Found upstairs unit have heavy condensation around unit due to lack of circulation and high humidity. Recommend to add dehumidifier to space to prevent sweating and further moisture issues.
Justin G.
Justin G. Checked in
Performed maintenance on 2 systems. Cleared pans and drains. Rinsed condenser coils. Filters clean. Electrical checked good. Pressures good. Temp split good. Both units cooling at this time. Found upstairs unit have heavy condensation around unit due to lack of circulation and high humidity. Recommend to add dehumidifier to space to prevent sweating and further moisture issues.
St. Petersburg, FL 33703
Upon replacing the existing thermostat, I found that the new thermostat wire installed by the electrician contains only five conductors, which is the same number of wires currently in use. A two-stage HVAC system requires additional conductors for proper operation with the new Nest thermostat, so simply replacing the existing five-wire cable with another five-wire cable is not sufficient.

The correct installation is an eight-conductor thermostat wire. Six conductors will be used for the system’s required connections, while the remaining two conductors will serve as spare wires for future service or upgrades.

If there are any questions or if further clarification is needed, please feel free to contact me.

Upon arrival, I installed the new thermostat, replaced the wires at the air handlers and reconnected the wires at the condenser. I set up the thermostat on customer’s phone and everything is working properly with a 20° temperature difference
Upon replacing the existing thermostat, I found that the new thermostat wire installed by the electrician contains only five conductors, which is the same number of wires currently in use. A two-stage HVAC system requires additional conductors for proper operation with the new Nest thermostat, so simply replacing the existing five-wire cable with another five-wire cable is not sufficient.

The correct installation is an eight-conductor thermostat wire. Six conductors will be used for the system’s required connections, while the remaining two conductors will serve as spare wires for future service or upgrades.

If there are any questions or if further clarification is needed, please feel free to contact me.

Upon arrival, I installed the new thermostat, replaced the wires at the air handlers and reconnected the wires at the condenser. I set up the thermostat on customer’s phone and everything is working properly with a 20° temperature difference
ihsan m.
ihsan m. Checked in
Upon replacing the existing thermostat, I found that the new thermostat wire installed by the electrician contains only five conductors, which is the same number of wires currently in use. A two-stage HVAC system requires additional conductors for proper operation with the new Nest thermostat, so simply replacing the existing five-wire cable with another five-wire cable is not sufficient. The correct installation is an eight-conductor thermostat wire. Six conductors will be used for the system’s required connections, while the remaining two conductors will serve as spare wires for future service or upgrades. If there are any questions or if further clarification is needed, please feel free to contact me. Upon arrival, I installed the new thermostat, replaced the wires at the air handlers and reconnected the wires at the condenser. I set up the thermostat on customer’s phone and everything is working properly with a 20° temperature difference
St. Petersburg, FL 33703
Found system had clogged drain and tripped primary safety float switch. 
Cleaned and treated drain line and primary drain. 
No guarantee on system longevity due to age and condition. 
System is cooling at this time with 20° temperature split. 
Providing quote to install mini split systems upstairs in 3 bedrooms
Found system had clogged drain and tripped primary safety float switch. 
Cleaned and treated drain line and primary drain. 
No guarantee on system longevity due to age and condition. 
System is cooling at this time with 20° temperature split. 
Providing quote to install mini split systems upstairs in 3 bedrooms
Michael A.
Michael A. Checked in
Found system had clogged drain and tripped primary safety float switch. Cleaned and treated drain line and primary drain. No guarantee on system longevity due to age and condition. System is cooling at this time with 20° temperature split. Providing quote to install mini split systems upstairs in 3 bedrooms
St. Petersburg, FL 33712
Griffin K.
Griffin K. Checked in
Trouble shot bedroom circuit found the extension cord on the exterior had burned up
St. Petersburg, FL 33704
Ricky O.
Ricky O. Checked in
RUUD Equipment (2 Stage) Install New Air Handler Install Air Handler UV System Install New Outdoor Condenser New Filter Drier Install Thermostat (Auto Changeover) Thermostat Wire Included Primary Float Safety Switch UV Rated Outdoor Insulation Refrigerant Locking Caps Flush Existing Refrigerant Lines Flush Drain Line Vibration Pads Hurricane Tie Down Straps Vacuum System Seal Supply/Return Plenums Remove Current Equipment Replace Breakers (As Needed) Permitting 10 Year Parts Warranty 3 Year Labor Warranty 100% Satisfaction *Replace Filter Back Register Return *415$ Repair Charge if Cancellation *Replace Outdoor Disconnect & Electrical Whip
St. Petersburg, FL 33703
ihsan m.
ihsan m. Checked in
Upon arrival, I inspected the air handler and found that the float switch had been triggered due to a clogged condensate drain line. The auxiliary drain pan was full of water, and the primary drain line was also clogged, preventing proper drainage. I performed an advanced drain line cleaning, which included a nitrogen flush and a thorough cleaning of the condensate drain system. I cleaned the primary and secondary drain pans as well as the condensate drain line and PVC piping to ensure all blockages were removed. After completing the cleaning, I tested the system to verify proper operation. The system is now draining correctly. I measured a 19°F temperature split between the supply and return air, refrigerant pressures are within the normal operating range, and all electrical components are functioning properly. During the inspection, I found that the run capacitor is testing below its rated value. I informed the homeowner that, while the system is currently operating, the capacitor
St. Petersburg, FL 33705
On arrival found unit not cooling due to blown fuse. Replaced fuse and test. Did not blow fuse again. Inspected indoor and outdoor units. Made client aware of problem persists will return and call tech support. Unit cooling at this time.
On arrival found unit not cooling due to blown fuse. Replaced fuse and test. Did not blow fuse again. Inspected indoor and outdoor units. Made client aware of problem persists will return and call tech support. Unit cooling at this time.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to blown fuse. Replaced fuse and test. Did not blow fuse again. Inspected indoor and outdoor units. Made client aware of problem persists will return and call tech support. Unit cooling at this time.
St. Petersburg, FL 33709
Performed two thermostat replacements, I made sure that they were programmed properly and make sure the systems were turning on onto cool mode. Please reach out to homeowner regarding upgrading his membership to ensure consistent filled to replacements included with the tuneup.
Performed two thermostat replacements, I made sure that they were programmed properly and make sure the systems were turning on onto cool mode. Please reach out to homeowner regarding upgrading his membership to ensure consistent filled to replacements included with the tuneup.
ihsan m.
ihsan m. Checked in
Performed two thermostat replacements, I made sure that they were programmed properly and make sure the systems were turning on onto cool mode. Please reach out to homeowner regarding upgrading his membership to ensure consistent filled to replacements included with the tuneup.
St. Petersburg, FL 33704
Install exterior GFCI receptacle and weather proof box on existing wire for sprinkler system
Install exterior GFCI receptacle and weather proof box on existing wire for sprinkler system
Griffin K.
Griffin K. Checked in
Install exterior GFCI receptacle and weather proof box on existing wire for sprinkler system
St. Petersburg, FL 33704
On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Added chemical to help prevent growth in pan. Pressures good. Temp split good. Rinsed condenser coil. Unit cooling properly at this time.
On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Added chemical to help prevent growth in pan. Pressures good. Temp split good. Rinsed condenser coil. Unit cooling properly at this time.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to clogged drain. Cleared pan and drain. Added chemical to help prevent growth in pan. Pressures good. Temp split good. Rinsed condenser coil. Unit cooling properly at this time.
St. Petersburg, FL 33703
Diagnostic 
-clogged drain line and drain pan 

Further Notes 
-bacterial growth on blower wheel/assembly 
-debris on back side of air handler coils 

Scope of Work
-clear drain line 
-clean drain pan and pan canals 
-add pan tablets to help with buildup 
-prime drain/trap

System is currently operating within manufacture specifications
Diagnostic 
-clogged drain line and drain pan 

Further Notes 
-bacterial growth on blower wheel/assembly 
-debris on back side of air handler coils 

Scope of Work
-clear drain line 
-clean drain pan and pan canals 
-add pan tablets to help with buildup 
-prime drain/trap

System is currently operating within manufacture specifications
Nathan A.
Nathan A. Checked in
Diagnostic -clogged drain line and drain pan Further Notes -bacterial growth on blower wheel/assembly -debris on back side of air handler coils Scope of Work -clear drain line -clean drain pan and pan canals -add pan tablets to help with buildup -prime drain/trap System is currently operating within manufacture specifications
St. Petersburg, FL 33704
Reason for call:
new system we didn't install she went with other company and then they said it was insulation after the install and new ducts. 
then another company came out and said it was the txv and it was brazed to close to something. customer wants an additional opinion there will be a 95$ service fee

Summary:
Unit is cooling with 22 degree split. Found schedule on stat I removed schedule. See no issue with the equipment. Homeowner has had Condneser replaced since install. No insulation in attic. Confirmed proper blower speed.
Reason for call:
new system we didn't install she went with other company and then they said it was insulation after the install and new ducts. 
then another company came out and said it was the txv and it was brazed to close to something. customer wants an additional opinion there will be a 95$ service fee

Summary:
Unit is cooling with 22 degree split. Found schedule on stat I removed schedule. See no issue with the equipment. Homeowner has had Condneser replaced since install. No insulation in attic. Confirmed proper blower speed.
Corbin C.
Corbin C. Checked in
Reason for call: new system we didn't install she went with other company and then they said it was insulation after the install and new ducts. then another company came out and said it was the txv and it was brazed to close to something. customer wants an additional opinion there will be a 95$ service fee Summary: Unit is cooling with 22 degree split. Found schedule on stat I removed schedule. See no issue with the equipment. Homeowner has had Condneser replaced since install. No insulation in attic. Confirmed proper blower speed.
St. Petersburg, FL 33701
Replace compressor. Start and test. Pressures good. Temp split good. Unit cooling at this time.
Replace compressor. Start and test. Pressures good. Temp split good. Unit cooling at this time.
Justin G.
Justin G. Checked in
Replace compressor. Start and test. Pressures good. Temp split good. Unit cooling at this time.
St. Petersburg, FL 33703
ihsan m.
ihsan m. Checked in
Upon arrival, I began by checking the temperature split between the supply and return air, which measured 20°F, indicating normal system performance. I then inspected the electrical components and found all equipment operating within manufacturer specifications, with no components over-amping. The refrigerant cycle was checked and is operating properly. As part of today’s maintenance, I performed a complete drain line treatment, cleaned the drain pan, cleaned the condenser coil, and completed a full air handler inspection. The system is operating properly at this time. If you have any questions or concerns, please don’t hesitate to reach out. Thank you for your business, and have a great day!
St. Petersburg, FL 33705
Ruud 3 ton heat pump
15 seer
5% cash discount avail
10 year parts warranty
3 year labor warranty
-Hurricane pad
-Hurricane tiedowns
-UV rated armorflex
-Horizontal pan
-Safety switches
-New thermostat (ask customer)
-Insulate drain line
-Flush drain line 
-New filter drier
-seal to existing plenums
-100% satisfaction guarantee
Ruud 3 ton heat pump
15 seer
5% cash discount avail
10 year parts warranty
3 year labor warranty
-Hurricane pad
-Hurricane tiedowns
-UV rated armorflex
-Horizontal pan
-Safety switches
-New thermostat (ask customer)
-Insulate drain line
-Flush drain line 
-New filter drier
-seal to existing plenums
-100% satisfaction guarantee
Kyle K.
Kyle K. Checked in
Ruud 3 ton heat pump 15 seer 5% cash discount avail 10 year parts warranty 3 year labor warranty -Hurricane pad -Hurricane tiedowns -UV rated armorflex -Horizontal pan -Safety switches -New thermostat (ask customer) -Insulate drain line -Flush drain line -New filter drier -seal to existing plenums -100% satisfaction guarantee
St. Petersburg, FL 33703
Master bedroom & Kitchen mini split blower pull and cleans. 
Discount -$100 for bundle at same time. 

Let client know that kitchen blower wheel is missing some fins. They told me that they accidentally hit it with a butter knife. 
Unit shakes when fan is in high speed.
Master bedroom & Kitchen mini split blower pull and cleans. 
Discount -$100 for bundle at same time. 

Let client know that kitchen blower wheel is missing some fins. They told me that they accidentally hit it with a butter knife. 
Unit shakes when fan is in high speed.
Michael A.
Michael A. Checked in
Master bedroom & Kitchen mini split blower pull and cleans. Discount -$100 for bundle at same time. Let client know that kitchen blower wheel is missing some fins. They told me that they accidentally hit it with a butter knife. Unit shakes when fan is in high speed.
St. Petersburg, FL 33713
Griffin K.
Griffin K. Checked in
Install a standard breaker on washer circuit does not require a stack GFCI breaker Rewire garage light switches so lights work independamtly
St. Petersburg, FL 33712
St. Petersburg, FL - Cut in new 18x18 return with filter back aluminum grill. Run new 14” to return plenum. Tax and labor included.
Justin G.
Justin G. Checked in
Cut in new 18x18 return with filter back aluminum grill. Run new 14” to return plenum. Tax and labor included.
St. Petersburg, FL 33703
Review
Great service, came to my place the same day I called. Nate is a great communicator and technician; he kept me informed each step along the way. Nate and Griffin (the electrical technician) are honest, trustworthy, prompt, knowledgeable , and a pleasure to work with. Highly recommend!
Susan A. Valot - St. Petersburg, FL 33703
Response from Air Bros Air Conditioning & Electrical:

Thank you, Susan, for your wonderful 5-star rating; your support means a lot to us!

Review
I had an outstanding experience with Air Bros from the moment I scheduled my service through to the completion of the job. Nate arrived right on schedule and was incredibly professional from start to finish. He performed a thorough preventative maintenance and cleaning of our system with a high attention to detail. He took the time to check our entire system and went above and beyond to answer all my questions in detail about maintenance tips to help prevent future issues. Nate's expertise, friendly demeanor and professionalism along with the entire scheduling process were truly amazing!
Marci Gleicher - St. Petersburg, FL 33704
Response from Air Bros Air Conditioning & Electrical:

Thank you, Marci, for sharing your wonderful experience and recognizing Nate's professionalism and dedication; we truly appreciate your feedback and are glad to know our service met your expectations!

Review
Air Bros has been my go-to for HVAC since I bought my house in 2017, and I wouldnt trust anyone else! Ricky has kept my old unit running like a champ for years, and when my house recently flooded, Justin showed up to get it back up and runningbuying me some time before I finally replace it (after 20 years, its definitely earned its retirement!). Theyre always on time, know their stuff, and even a hit with my dogs. If you want honest, reliable, high-quality service in St. Pete, these guys are the way to go!
Amelia Johnson - St. Petersburg, FL 33704
Response from Air Bros Air Conditioning & Electrical:

Thank you, Amelia, for your kind words and for being a loyal customer since 2017! We're glad to hear that Ricky has kept your unit running smoothly and that Justin was there to help during a tough time. It means a lot to us to know we can provide reliable service for you and your furry friends!

Review
Nathan helped me out on very short notice, super professional and polite. Definitely will call again if need arises.
Ante Gotovina - St. Petersburg, FL 33704
Response from Air Bros Air Conditioning & Electrical:

Thank you, Ante, for your kind words about Nathan's professionalism and quick assistance; we look forward to helping you again in the future!

Contact the Bros You Know Today!

Schedule Service Online
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at 727-217-6148 .

By pressing Submit I agree to receive phone, email, or text messages from Air Bros Air Conditioning & Heating to the provided mobile number and also agree to the Air Bros Air Conditioning & Heating terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next