Instant Quote Shop Filters Call Air Bros Book Service

St. Petersburg, FL

air-bros-team-with-truck

Your St. Petersburg, FL HVAC Experts

Air Bros Air Conditioning & Heating is proud to serve the vibrant community of St. Petersburg, FL. We understand the unique challenges that St. Petersburg homeowners and businesses face when it comes to maintaining comfortable indoor temperatures year-round. Our team of experienced and certified technicians is dedicated to providing top-quality HVAC services tailored to the specific needs of our St. Petersburg customers.

Call us at 727-217-6148 or contact us online today for all of your HVAC, indoor air quality and electrical needs.

Comprehensive HVAC Services in St. Petersburg

We offer a full range of heating and cooling services to keep your St. Petersburg, FL, home comfortable year-round:

  • Air Conditioning: From AC repair and AC installation to routine maintenance, we ensure your cooling system keeps you comfortable during those hot Florida summers. We offer same-day service for AC emergencies, so you never have to suffer in the heat.
  • Heating: Stay warm and cozy in the winter with our comprehensive heating services. We repair and install all types of heating systems, including furnaces and heat pumps, and offer preventative maintenance to keep your system running efficiently.
  • Indoor Air Quality: Improve your indoor air quality with our dehumidifier and UV light installation services. We'll help you control excess humidity and eliminate airborne contaminants, creating a healthier home environment.
  • Ductwork: Ensure optimal airflow and energy efficiency with our ductwork repair and installation services. We can address leaks and damage, and design a system that's perfect for your home.
  • Pool Heater Services: Extend your swim season with our pool heater installation and repair services.
  • Electrical Services: From outlet and switch replacements to ceiling fan installations to whole-house surge protector installations, we have the experts to handle your electrical service needs.

Our experienced technicians are skilled in all aspects of HVAC service and are dedicated to providing top-quality workmanship and customer care.

Why Choose Air Bros?

  • Local Expertise: We understand the unique climate challenges of St. Petersburg.
  • Fast and Reliable Service: We offer same-day service for AC emergencies and prioritize prompt service for all your HVAC needs.
  • Experienced Technicians: Our team is highly trained and experienced in all aspects of HVAC service.
  • Upfront Pricing: We provide transparent pricing with no hidden costs.
  • Customer Satisfaction Guaranteed: Your comfort and satisfaction are our top priorities.

Contact Air Bros Today!

Whether you need emergency AC repair, a new heating system installation, or any other HVAC service, Air Bros is here to help. Contact us today for a free consultation or to schedule a service appointment. We're proud to be your trusted HVAC partner in St. Petersburg!

Call us at 727-217-6148 or contact us online today!

Our St. Petersburg Location

Address: 1579 Delaware Ave NESt. Petersburg, FL 33703

Phone: 727-217-6148

Count on perfect service; Trust the bros you know!

Recent Jobs and Reviews in St. Petersburg, FL

Job Locations and Reviews

Upon my inspection, found York Inverter system indoor blower motor barely spinning. Pressures are good and temp split is good. Found no error codes or alarms. Reset system and blower motor began to ramp up to proper speed. System is cooling at this time. There were multiple power outages today in the area. Recommended installing voltage monitor and surge protection on system as this is an inverter system and it is sensitive to voltage surges. 
Sent over quote for surge protection package. 

Charge for labor and system reset today with member discount. 

If system continues to have issues, we will need to return to either talk with tech support for $495 or replace warranty blower motor and control board for $1230.
Upon my inspection, found York Inverter system indoor blower motor barely spinning. Pressures are good and temp split is good. Found no error codes or alarms. Reset system and blower motor began to ramp up to proper speed. System is cooling at this time. There were multiple power outages today in the area. Recommended installing voltage monitor and surge protection on system as this is an inverter system and it is sensitive to voltage surges. 
Sent over quote for surge protection package. 

Charge for labor and system reset today with member discount. 

If system continues to have issues, we will need to return to either talk with tech support for $495 or replace warranty blower motor and control board for $1230.
Michael A.
Michael A. Checked in
Upon my inspection, found York Inverter system indoor blower motor barely spinning. Pressures are good and temp split is good. Found no error codes or alarms. Reset system and blower motor began to ramp up to proper speed. System is cooling at this time. There were multiple power outages today in the area. Recommended installing voltage monitor and surge protection on system as this is an inverter system and it is sensitive to voltage surges. Sent over quote for surge protection package. Charge for labor and system reset today with member discount. If system continues to have issues, we will need to return to either talk with tech support for $495 or replace warranty blower motor and control board for $1230.
St. Petersburg, FL 33703
Client states that unit made horribly loud noise and then whole home power went out. Client stated that Duke energy has been giving them issues lately with power outages randomly. System is working properly at this time with good temp split and good amp draws. 
No current issues at this time. Client said that it look a while for the system to come back on. I determined this was the result of the ecobee thermostat needing to calibrate for 15 minutes before sending signal for system to turn back on.
Client states that unit made horribly loud noise and then whole home power went out. Client stated that Duke energy has been giving them issues lately with power outages randomly. System is working properly at this time with good temp split and good amp draws. 
No current issues at this time. Client said that it look a while for the system to come back on. I determined this was the result of the ecobee thermostat needing to calibrate for 15 minutes before sending signal for system to turn back on.
Michael A.
Michael A. Checked in
Client states that unit made horribly loud noise and then whole home power went out. Client stated that Duke energy has been giving them issues lately with power outages randomly. System is working properly at this time with good temp split and good amp draws. No current issues at this time. Client said that it look a while for the system to come back on. I determined this was the result of the ecobee thermostat needing to calibrate for 15 minutes before sending signal for system to turn back on.
St. Petersburg, FL 33703
Mini split  system in detached home not cooling. Found system running but not blowing cool air. System pressures are completely flat and system is actually pulling a vacuum. Performed leak search and found leak at 4 way reversing valve inside condenser. This hole is large and blowing refrigerant charge quickly. 
Submitting estimate for reversing valve replacement as well as whole system replacement. Client says they want to reach out to the guy who installed the system and see if they can do anything about it for less.
Mini split  system in detached home not cooling. Found system running but not blowing cool air. System pressures are completely flat and system is actually pulling a vacuum. Performed leak search and found leak at 4 way reversing valve inside condenser. This hole is large and blowing refrigerant charge quickly. 
Submitting estimate for reversing valve replacement as well as whole system replacement. Client says they want to reach out to the guy who installed the system and see if they can do anything about it for less.
Michael A.
Michael A. Checked in
Mini split system in detached home not cooling. Found system running but not blowing cool air. System pressures are completely flat and system is actually pulling a vacuum. Performed leak search and found leak at 4 way reversing valve inside condenser. This hole is large and blowing refrigerant charge quickly. Submitting estimate for reversing valve replacement as well as whole system replacement. Client says they want to reach out to the guy who installed the system and see if they can do anything about it for less.
St. Petersburg, FL 33703
Waived diagnostic with repair 

Replaced failed outdoor capacitor 

Verified system operations
Waived diagnostic with repair 

Replaced failed outdoor capacitor 

Verified system operations
Nathan A.
Nathan A. Checked in
Waived diagnostic with repair Replaced failed outdoor capacitor Verified system operations
St. Petersburg, FL 33710
Upon my inspection found system drain line completely clogged. Performed level three drain cleaning. Also performed a quick drain cleaning on the main system in the laundry room while on site (complimentary). 
Guest bedroom system does not have a good temperature split and is at a 8° split. Let client know and he would like to leave it alone. Main system has a 20° temperature split. 

Cleaned filter on bedroom system while here as well. 
Client is not interested in Maitenence plan as they plan on selling home in near future.
Upon my inspection found system drain line completely clogged. Performed level three drain cleaning. Also performed a quick drain cleaning on the main system in the laundry room while on site (complimentary). 
Guest bedroom system does not have a good temperature split and is at a 8° split. Let client know and he would like to leave it alone. Main system has a 20° temperature split. 

Cleaned filter on bedroom system while here as well. 
Client is not interested in Maitenence plan as they plan on selling home in near future.
Michael A.
Michael A. Checked in
Upon my inspection found system drain line completely clogged. Performed level three drain cleaning. Also performed a quick drain cleaning on the main system in the laundry room while on site (complimentary). Guest bedroom system does not have a good temperature split and is at a 8° split. Let client know and he would like to leave it alone. Main system has a 20° temperature split. Cleaned filter on bedroom system while here as well. Client is not interested in Maitenence plan as they plan on selling home in near future.
St. Petersburg, FL 33701

Upon my inspection, found water damage in ceiling from second floor. Air handler has a faulty safety float switch and no p trap installed. System also has very dirty filters that need to be changed. Replaces and tested safety float switch. Installed p trap. Replaced filters with what the client had supplied. Started system and tested drain. 

Client would like to keep system at 65° at night. This temperature is hard to maintain. Recommended mini splits in the master bedrooms. We will be installing one mini splits system in the Casita room to start. 

Filter sizes needed for client to order themselves: 
5 12x12
2 12x24
1 20x20

Upon my inspection, found water damage in ceiling from second floor. Air handler has a faulty safety float switch and no p trap installed. System also has very dirty filters that need to be changed. Replaces and tested safety float switch. Installed p trap. Replaced filters with what the client had supplied. Started system and tested drain. 

Client would like to keep system at 65° at night. This temperature is hard to maintain. Recommended mini splits in the master bedrooms. We will be installing one mini splits system in the Casita room to start. 

Filter sizes needed for client to order themselves: 
5 12x12
2 12x24
1 20x20
Michael A.
Michael A. Checked in
Upon my inspection, found water damage in ceiling from second floor. Air handler has a faulty safety float switch and no p trap installed. System also has very dirty filters that need to be changed. Replaces and tested safety float switch. Installed p trap. Replaced filters with what the client had supplied. Started system and tested drain. Client would like to keep system at 65° at night. This temperature is hard to maintain. Recommended mini splits in the master bedrooms. We will be installing one mini splits system in the Casita room to start. Filter sizes needed for client to order themselves: 5 12x12 2 12x24 1 20x20
St. Petersburg, FL 33704
Upon my inspection? Found water leak in garage coming from air handler. Drain line is severely clogged and drain connections are not glued and missing insulation causing the water to escape the pipe. Performed daydream, cleaning and treatment, and re-piped drain line near the air handler. Client signed up for maintenance plan. Performed first maintenance on system. System is cooling with a 19° temperature split. Amp draws are all good, capacitor is within factory range, contactor looks ok. Found heavy amount of growth on indoor blower wheel. The extra weight on this wheel will put more strain on the fan motor.
Also found heavy amount of corrosion on condenser coils on the left side of the service panel. This section is at risk of a refrigerant leak. 

Client is preparing for a new system instead of investing more into this 12 year old system.
Upon my inspection? Found water leak in garage coming from air handler. Drain line is severely clogged and drain connections are not glued and missing insulation causing the water to escape the pipe. Performed daydream, cleaning and treatment, and re-piped drain line near the air handler. Client signed up for maintenance plan. Performed first maintenance on system. System is cooling with a 19° temperature split. Amp draws are all good, capacitor is within factory range, contactor looks ok. Found heavy amount of growth on indoor blower wheel. The extra weight on this wheel will put more strain on the fan motor.
Also found heavy amount of corrosion on condenser coils on the left side of the service panel. This section is at risk of a refrigerant leak. 

Client is preparing for a new system instead of investing more into this 12 year old system.
Michael A.
Michael A. Checked in
Upon my inspection? Found water leak in garage coming from air handler. Drain line is severely clogged and drain connections are not glued and missing insulation causing the water to escape the pipe. Performed daydream, cleaning and treatment, and re-piped drain line near the air handler. Client signed up for maintenance plan. Performed first maintenance on system. System is cooling with a 19° temperature split. Amp draws are all good, capacitor is within factory range, contactor looks ok. Found heavy amount of growth on indoor blower wheel. The extra weight on this wheel will put more strain on the fan motor. Also found heavy amount of corrosion on condenser coils on the left side of the service panel. This section is at risk of a refrigerant leak. Client is preparing for a new system instead of investing more into this 12 year old system.
St. Petersburg, FL 33704
Diagnostic 
-low voltage short causing system not to run. Found low voltage short in outdoor wiring. 
-found shoe lace tied around outdoor motor 
-air handler has been running without filter (coils extremely impacted)

Scope of work 
-fixed wiring & short 
-replaced fuse 
-replaced thermostat batteries 
-pulled bag off back side of coils 
-removed shoe lace 

Verified system operations. System is 16 years of age. Unit was ran without filter during construction. Would recommend replacing coils or system. Systems running to best of abilities.
Diagnostic 
-low voltage short causing system not to run. Found low voltage short in outdoor wiring. 
-found shoe lace tied around outdoor motor 
-air handler has been running without filter (coils extremely impacted)

Scope of work 
-fixed wiring & short 
-replaced fuse 
-replaced thermostat batteries 
-pulled bag off back side of coils 
-removed shoe lace 

Verified system operations. System is 16 years of age. Unit was ran without filter during construction. Would recommend replacing coils or system. Systems running to best of abilities.
Nathan A.
Nathan A. Checked in
Diagnostic -low voltage short causing system not to run. Found low voltage short in outdoor wiring. -found shoe lace tied around outdoor motor -air handler has been running without filter (coils extremely impacted) Scope of work -fixed wiring & short -replaced fuse -replaced thermostat batteries -pulled bag off back side of coils -removed shoe lace Verified system operations. System is 16 years of age. Unit was ran without filter during construction. Would recommend replacing coils or system. Systems running to best of abilities.
St. Petersburg, FL 33713
Reason for call:
Tune up on two unit 

Equipment:
Unit #4 
2016 4 ton trane 
Horizontal on hang kit 
Condenser out back in wall mount 

Unit #5 
2016 4 ton trane
Horizontal on hang kit 
Condenser out back in wall mount 

Summary:
Completed tune up to find both unit low on 410 a refrigerant. Found both condenser to have poorly insulated low voltage wire. Flushed drain line. Filters need attention 22x20x1 replace one per quarter. 
Pressure low. Unit 4 td 16  unit 5 td 25 

Solution:
Recommended we require both condenser low voltage, add refrigerant to each unit, and Perron leak search to determine where systems are leaking refrigerant.
Reason for call:
Tune up on two unit 

Equipment:
Unit #4 
2016 4 ton trane 
Horizontal on hang kit 
Condenser out back in wall mount 

Unit #5 
2016 4 ton trane
Horizontal on hang kit 
Condenser out back in wall mount 

Summary:
Completed tune up to find both unit low on 410 a refrigerant. Found both condenser to have poorly insulated low voltage wire. Flushed drain line. Filters need attention 22x20x1 replace one per quarter. 
Pressure low. Unit 4 td 16  unit 5 td 25 

Solution:
Recommended we require both condenser low voltage, add refrigerant to each unit, and Perron leak search to determine where systems are leaking refrigerant.
Corbin C.
Corbin C. Checked in
Reason for call: Tune up on two unit Equipment: Unit #4 2016 4 ton trane Horizontal on hang kit Condenser out back in wall mount Unit #5 2016 4 ton trane Horizontal on hang kit Condenser out back in wall mount Summary: Completed tune up to find both unit low on 410 a refrigerant. Found both condenser to have poorly insulated low voltage wire. Flushed drain line. Filters need attention 22x20x1 replace one per quarter. Pressure low. Unit 4 td 16 unit 5 td 25 Solution: Recommended we require both condenser low voltage, add refrigerant to each unit, and Perron leak search to determine where systems are leaking refrigerant.
St. Petersburg, FL 33712
Reason for call:
Member tune up 

Equipment:
2017 Icp 2.5 ton straight cool 
Horizontal in attic 
Condenser on right side of home 

Summary:
Completed tune up. Confirmed operation of equipment within manufacturing specifications. Flushed indoor and outdoor coils. Flushed drain line. Confirmed pressures. Filters have been maintained. Homeowner wanted to add uv treatment kit

Solution:
Will improve air quality within home and help keep air handler clean. 
Including install and warranty 
1 year parts and labor on uv treatment
Reason for call:
Member tune up 

Equipment:
2017 Icp 2.5 ton straight cool 
Horizontal in attic 
Condenser on right side of home 

Summary:
Completed tune up. Confirmed operation of equipment within manufacturing specifications. Flushed indoor and outdoor coils. Flushed drain line. Confirmed pressures. Filters have been maintained. Homeowner wanted to add uv treatment kit

Solution:
Will improve air quality within home and help keep air handler clean. 
Including install and warranty 
1 year parts and labor on uv treatment
Corbin C.
Corbin C. Checked in
Reason for call: Member tune up Equipment: 2017 Icp 2.5 ton straight cool Horizontal in attic Condenser on right side of home Summary: Completed tune up. Confirmed operation of equipment within manufacturing specifications. Flushed indoor and outdoor coils. Flushed drain line. Confirmed pressures. Filters have been maintained. Homeowner wanted to add uv treatment kit Solution: Will improve air quality within home and help keep air handler clean. Including install and warranty 1 year parts and labor on uv treatment
St. Petersburg, FL 33713
On arrival found downstairs unit not cooling due to tripped breaker. Turned breaker on and heard arcing behind panel cover. Turned off power and removed panel cover. Observed loose connection causing wire to burn. Replaced breaker and cut out bad wire. Start and test. Amp draws good. Temp split good. Pressures good. Capacitor in range. Unit cooling properly at this time.
On arrival found downstairs unit not cooling due to tripped breaker. Turned breaker on and heard arcing behind panel cover. Turned off power and removed panel cover. Observed loose connection causing wire to burn. Replaced breaker and cut out bad wire. Start and test. Amp draws good. Temp split good. Pressures good. Capacitor in range. Unit cooling properly at this time.
Justin G.
Justin G. Checked in
On arrival found downstairs unit not cooling due to tripped breaker. Turned breaker on and heard arcing behind panel cover. Turned off power and removed panel cover. Observed loose connection causing wire to burn. Replaced breaker and cut out bad wire. Start and test. Amp draws good. Temp split good. Pressures good. Capacitor in range. Unit cooling properly at this time.
St. Petersburg, FL 33702
Reason for call:
Water leak on mini split 

Waived diagnostic with repair 

Equipment:
Single zone pioneer mini split 

Summary:
On arrival found mini split to operate well good pressures and temperature. Found drain line clogged and indoor unit I need of a full cleaning blower, coil, and panels. 
Homeowner wanted to clean drain only. 
Drain clean. Unit is operating properly again not leaking water.
Reason for call:
Water leak on mini split 

Waived diagnostic with repair 

Equipment:
Single zone pioneer mini split 

Summary:
On arrival found mini split to operate well good pressures and temperature. Found drain line clogged and indoor unit I need of a full cleaning blower, coil, and panels. 
Homeowner wanted to clean drain only. 
Drain clean. Unit is operating properly again not leaking water.
Corbin C.
Corbin C. Checked in
Reason for call: Water leak on mini split Waived diagnostic with repair Equipment: Single zone pioneer mini split Summary: On arrival found mini split to operate well good pressures and temperature. Found drain line clogged and indoor unit I need of a full cleaning blower, coil, and panels. Homeowner wanted to clean drain only. Drain clean. Unit is operating properly again not leaking water.
St. Petersburg, FL 33711
Client states condenser was shutting off and air handler still running. Inspected unit for issues. Pressures ok. Temp split good. Electrical checked good. Unit has leak detector system built in. Could be possible leak in coil or intermittent issue. Told client to not reset breaker again to prevent clearing any fault codes for system. Unit cooling at this time.
Client states condenser was shutting off and air handler still running. Inspected unit for issues. Pressures ok. Temp split good. Electrical checked good. Unit has leak detector system built in. Could be possible leak in coil or intermittent issue. Told client to not reset breaker again to prevent clearing any fault codes for system. Unit cooling at this time.
Justin G.
Justin G. Checked in
Client states condenser was shutting off and air handler still running. Inspected unit for issues. Pressures ok. Temp split good. Electrical checked good. Unit has leak detector system built in. Could be possible leak in coil or intermittent issue. Told client to not reset breaker again to prevent clearing any fault codes for system. Unit cooling at this time.
St. Petersburg, FL 33702
Upstairs system issue:
Found clogged drain line. Performed drain cleaning and treatment on system. Client signed up for 2 system Maitenence plan. 
Tested drain line and found the existing drain line upstairs is a little higher than it should be and is giving a not great slope for the condensate. Let client know if this is an issue in the future we will need to shorten the existing drain line to allow for better drain slope coming from the unit. 
System is cooling at this time.
Upstairs system issue:
Found clogged drain line. Performed drain cleaning and treatment on system. Client signed up for 2 system Maitenence plan. 
Tested drain line and found the existing drain line upstairs is a little higher than it should be and is giving a not great slope for the condensate. Let client know if this is an issue in the future we will need to shorten the existing drain line to allow for better drain slope coming from the unit. 
System is cooling at this time.
Michael A.
Michael A. Checked in
Upstairs system issue: Found clogged drain line. Performed drain cleaning and treatment on system. Client signed up for 2 system Maitenence plan. Tested drain line and found the existing drain line upstairs is a little higher than it should be and is giving a not great slope for the condensate. Let client know if this is an issue in the future we will need to shorten the existing drain line to allow for better drain slope coming from the unit. System is cooling at this time.
St. Petersburg, FL 33701
On arrival found unit not cooling due to improper txv in air handler. Will submit estimates for repair and replacement options. Unit cooling to the best of its ability at this time.
On arrival found unit not cooling due to improper txv in air handler. Will submit estimates for repair and replacement options. Unit cooling to the best of its ability at this time.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to improper txv in air handler. Will submit estimates for repair and replacement options. Unit cooling to the best of its ability at this time.
St. Petersburg, FL 33710
Upon arrival, I found that the air handler was operating, but the condenser was not running. I reset power at the air handler, which restored operation to the condenser. After checking system pressures, I found the refrigerant charge to be low. The initial temperature differential was 13°, which is below the desired range.

I added refrigerant and allowed the system to operate for approximately 45 minutes. After the adjustment, the temperature differential improved to 17°, indicating better system performance.

While on site, I also completed a maintenance service, which included cleaning the condenser coil, treating the drain line, and performing a full air handler inspection. All electrical components were checked and found to be operating properly with no issues at this time.

The system is currently cooling and operating normally. However, because the exact cause of the low refrigerant condition has not yet been confirmed, the issue may not be fully resolved. At this time, the syst
Upon arrival, I found that the air handler was operating, but the condenser was not running. I reset power at the air handler, which restored operation to the condenser. After checking system pressures, I found the refrigerant charge to be low. The initial temperature differential was 13°, which is below the desired range.

I added refrigerant and allowed the system to operate for approximately 45 minutes. After the adjustment, the temperature differential improved to 17°, indicating better system performance.

While on site, I also completed a maintenance service, which included cleaning the condenser coil, treating the drain line, and performing a full air handler inspection. All electrical components were checked and found to be operating properly with no issues at this time.

The system is currently cooling and operating normally. However, because the exact cause of the low refrigerant condition has not yet been confirmed, the issue may not be fully resolved. At this time, the syst
ihsan m.
ihsan m. Checked in
Upon arrival, I found that the air handler was operating, but the condenser was not running. I reset power at the air handler, which restored operation to the condenser. After checking system pressures, I found the refrigerant charge to be low. The initial temperature differential was 13°, which is below the desired range. I added refrigerant and allowed the system to operate for approximately 45 minutes. After the adjustment, the temperature differential improved to 17°, indicating better system performance. While on site, I also completed a maintenance service, which included cleaning the condenser coil, treating the drain line, and performing a full air handler inspection. All electrical components were checked and found to be operating properly with no issues at this time. The system is currently cooling and operating normally. However, because the exact cause of the low refrigerant condition has not yet been confirmed, the issue may not be fully resolved. At this time, the syst
St. Petersburg, FL 33702
St. Petersburg, FL - Found condensate pump shutting off due to loose electrical outlet. Recommend to replace receptacle to prevent pump from shutting off.
Justin G.
Justin G. Checked in
Found condensate pump shutting off due to loose electrical outlet. Recommend to replace receptacle to prevent pump from shutting off.
St. Petersburg, FL 33703
Replace EEV stepper motor and board

Completed repair confirmed pressures to be slightly low. Informed homeowner about a leak search and top off they want to top off for now. Added 3.5 pounds of 410 to system. 

Proper operation was restored to equipment.
Replace EEV stepper motor and board

Completed repair confirmed pressures to be slightly low. Informed homeowner about a leak search and top off they want to top off for now. Added 3.5 pounds of 410 to system. 

Proper operation was restored to equipment.
Corbin C.
Corbin C. Checked in
Replace EEV stepper motor and board Completed repair confirmed pressures to be slightly low. Informed homeowner about a leak search and top off they want to top off for now. Added 3.5 pounds of 410 to system. Proper operation was restored to equipment.
St. Petersburg, FL 33702
Reason for call:
No cool 

Equipment:
2022 ruud 
Horizontal in attic 
Condenser in front of home 

Summary:
Found unit off on float switch on arrival found capacitor weak. Flushed drain line and pan to restore drainage. Replaced capacitor due to weak readings. Unit is up and cooling again.
Reason for call:
No cool 

Equipment:
2022 ruud 
Horizontal in attic 
Condenser in front of home 

Summary:
Found unit off on float switch on arrival found capacitor weak. Flushed drain line and pan to restore drainage. Replaced capacitor due to weak readings. Unit is up and cooling again.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Equipment: 2022 ruud Horizontal in attic Condenser in front of home Summary: Found unit off on float switch on arrival found capacitor weak. Flushed drain line and pan to restore drainage. Replaced capacitor due to weak readings. Unit is up and cooling again.
St. Petersburg, FL 33705
RUUD Equipment (2 Stage)
Install New Air Handler 
Install 1” Filter Rack Riser 
Install Air Handler UV System
Install New Outdoor Condenser 
New Filter Drier 
Install Thermostat (Ecobee)
Thermostat Wire Included 
Primary Float Safety Switch
Outdoor Surge Protection 
UV Rated Outdoor Insulation 
Refrigerant Locking Caps
Flush Existing Refrigerant Lines
Flush Drain Line
4” Hurricane Pad
Vibration Pads
Hurricane Tie Down Straps
Vacuum System 
Seal Supply/Return Plenums 
Remove Current Equipment
Replace Breakers (As Needed)
Permitting 
10 Year Parts Warranty
3 Year Labor Warranty 
100% Satisfaction 

*Complimentary 410a fill up (1-2lb)

*Cash price 9,500
RUUD Equipment (2 Stage)
Install New Air Handler 
Install 1” Filter Rack Riser 
Install Air Handler UV System
Install New Outdoor Condenser 
New Filter Drier 
Install Thermostat (Ecobee)
Thermostat Wire Included 
Primary Float Safety Switch
Outdoor Surge Protection 
UV Rated Outdoor Insulation 
Refrigerant Locking Caps
Flush Existing Refrigerant Lines
Flush Drain Line
4” Hurricane Pad
Vibration Pads
Hurricane Tie Down Straps
Vacuum System 
Seal Supply/Return Plenums 
Remove Current Equipment
Replace Breakers (As Needed)
Permitting 
10 Year Parts Warranty
3 Year Labor Warranty 
100% Satisfaction 

*Complimentary 410a fill up (1-2lb)

*Cash price 9,500
Martin W.
Martin W. Checked in
RUUD Equipment (2 Stage) Install New Air Handler Install 1” Filter Rack Riser Install Air Handler UV System Install New Outdoor Condenser New Filter Drier Install Thermostat (Ecobee) Thermostat Wire Included Primary Float Safety Switch Outdoor Surge Protection UV Rated Outdoor Insulation Refrigerant Locking Caps Flush Existing Refrigerant Lines Flush Drain Line 4” Hurricane Pad Vibration Pads Hurricane Tie Down Straps Vacuum System Seal Supply/Return Plenums Remove Current Equipment Replace Breakers (As Needed) Permitting 10 Year Parts Warranty 3 Year Labor Warranty 100% Satisfaction *Complimentary 410a fill up (1-2lb) *Cash price 9,500
St. Petersburg, FL 33713
Performed a maintenance on the HVAC system, I had a 20° temperature difference over all the system mechanically was functioning properly. I cleaned the drain line, the drain pan. I offered the homeowner the membership program which he agreed upon.
Performed a maintenance on the HVAC system, I had a 20° temperature difference over all the system mechanically was functioning properly. I cleaned the drain line, the drain pan. I offered the homeowner the membership program which he agreed upon.
ihsan m.
ihsan m. Checked in
Performed a maintenance on the HVAC system, I had a 20° temperature difference over all the system mechanically was functioning properly. I cleaned the drain line, the drain pan. I offered the homeowner the membership program which he agreed upon.
St. Petersburg, FL 33701
Install Single 12k BTU Head 
Remote/App Operated 
Install Hurricane Pad 
Hurricane Tie Down Straps
Vibration Pads
New Refrigerant Lines
New Communication Wire
Install Hard Pipe PVC Drain
Install Exterior Line Covers
Install Single 12k Outdoor Condenser 
Seal Penetration Points 
Pressure Test Systems 
Vacuum Systems 
Charge Systems 
UV Rated Outdoor Insulation 
Refrigerant Locking Caps
Outdoor Surge Protection 
New Outdoor Electrical Whip
New Outdoor Electrical Disconnect  
Replace Breakers (As Needed)
12 Year Parts Warranty 
3 Year Labor Warranty 

*Remove old condenser 
*Cut back lines at line cover and spray foam 
*Use high voltage from condenser
Install Single 12k BTU Head 
Remote/App Operated 
Install Hurricane Pad 
Hurricane Tie Down Straps
Vibration Pads
New Refrigerant Lines
New Communication Wire
Install Hard Pipe PVC Drain
Install Exterior Line Covers
Install Single 12k Outdoor Condenser 
Seal Penetration Points 
Pressure Test Systems 
Vacuum Systems 
Charge Systems 
UV Rated Outdoor Insulation 
Refrigerant Locking Caps
Outdoor Surge Protection 
New Outdoor Electrical Whip
New Outdoor Electrical Disconnect  
Replace Breakers (As Needed)
12 Year Parts Warranty 
3 Year Labor Warranty 

*Remove old condenser 
*Cut back lines at line cover and spray foam 
*Use high voltage from condenser
Kyle K.
Kyle K. Checked in
Install Single 12k BTU Head Remote/App Operated Install Hurricane Pad Hurricane Tie Down Straps Vibration Pads New Refrigerant Lines New Communication Wire Install Hard Pipe PVC Drain Install Exterior Line Covers Install Single 12k Outdoor Condenser Seal Penetration Points Pressure Test Systems Vacuum Systems Charge Systems UV Rated Outdoor Insulation Refrigerant Locking Caps Outdoor Surge Protection New Outdoor Electrical Whip New Outdoor Electrical Disconnect Replace Breakers (As Needed) 12 Year Parts Warranty 3 Year Labor Warranty *Remove old condenser *Cut back lines at line cover and spray foam *Use high voltage from condenser
St. Petersburg, FL 33707
Upon my system, found shorted fuse at the air handler. Performed a low-voltage short inspection. Found a short at the condenser contactor. Replace this contactor and replace the three amp fuse at the air handler. System started up and has a 20° temperature split. Amp draw on compressor and fan motor are good. Capacitor is within factory tolerance limits. Recommended a maintenance plan for the system as Client just moved in four months ago and has not had a proper maintenance yet. Sending quote for single system maintenance plan.
Waived $95 service fee with repair
Upon my system, found shorted fuse at the air handler. Performed a low-voltage short inspection. Found a short at the condenser contactor. Replace this contactor and replace the three amp fuse at the air handler. System started up and has a 20° temperature split. Amp draw on compressor and fan motor are good. Capacitor is within factory tolerance limits. Recommended a maintenance plan for the system as Client just moved in four months ago and has not had a proper maintenance yet. Sending quote for single system maintenance plan.
Waived $95 service fee with repair
Michael A.
Michael A. Checked in
Upon my system, found shorted fuse at the air handler. Performed a low-voltage short inspection. Found a short at the condenser contactor. Replace this contactor and replace the three amp fuse at the air handler. System started up and has a 20° temperature split. Amp draw on compressor and fan motor are good. Capacitor is within factory tolerance limits. Recommended a maintenance plan for the system as Client just moved in four months ago and has not had a proper maintenance yet. Sending quote for single system maintenance plan. Waived $95 service fee with repair
St. Petersburg, FL 33703
Reason for call:
No cool

Equipment:
2021 3 ton straight cool Icp
Vertical in closet 
Condenser out back 

Summary:
On arrival found system low on refrigerant charge. Found drain line clogged, clean drain free of charge as courtesy. Found leak inside condenser coil. Condenser coil will have to be replaced. Clients have temporary coping until repair can be done.
Reason for call:
No cool

Equipment:
2021 3 ton straight cool Icp
Vertical in closet 
Condenser out back 

Summary:
On arrival found system low on refrigerant charge. Found drain line clogged, clean drain free of charge as courtesy. Found leak inside condenser coil. Condenser coil will have to be replaced. Clients have temporary coping until repair can be done.
Corbin C.
Corbin C. Checked in
Reason for call: No cool Equipment: 2021 3 ton straight cool Icp Vertical in closet Condenser out back Summary: On arrival found system low on refrigerant charge. Found drain line clogged, clean drain free of charge as courtesy. Found leak inside condenser coil. Condenser coil will have to be replaced. Clients have temporary coping until repair can be done.
St. Petersburg, FL 33711
Unit is operating within manufacture specifications. No sounds at this time. Home owner states it could be coming from the above unit.
Unit is operating within manufacture specifications. No sounds at this time. Home owner states it could be coming from the above unit.
Nathan A.
Nathan A. Checked in
Unit is operating within manufacture specifications. No sounds at this time. Home owner states it could be coming from the above unit.
St. Petersburg, FL 33702
Review
Great service, came to my place the same day I called. Nate is a great communicator and technician; he kept me informed each step along the way. Nate and Griffin (the electrical technician) are honest, trustworthy, prompt, knowledgeable , and a pleasure to work with. Highly recommend!
Susan A. Valot - St. Petersburg, FL 33703
Response from Air Bros Air Conditioning & Electrical:

Thank you, Susan, for your wonderful 5-star rating; your support means a lot to us!

Review
I had an outstanding experience with Air Bros from the moment I scheduled my service through to the completion of the job. Nate arrived right on schedule and was incredibly professional from start to finish. He performed a thorough preventative maintenance and cleaning of our system with a high attention to detail. He took the time to check our entire system and went above and beyond to answer all my questions in detail about maintenance tips to help prevent future issues. Nate's expertise, friendly demeanor and professionalism along with the entire scheduling process were truly amazing!
Marci Gleicher - St. Petersburg, FL 33704
Response from Air Bros Air Conditioning & Electrical:

Thank you, Marci, for sharing your wonderful experience and recognizing Nate's professionalism and dedication; we truly appreciate your feedback and are glad to know our service met your expectations!

Review
Air Bros has been my go-to for HVAC since I bought my house in 2017, and I wouldnt trust anyone else! Ricky has kept my old unit running like a champ for years, and when my house recently flooded, Justin showed up to get it back up and runningbuying me some time before I finally replace it (after 20 years, its definitely earned its retirement!). Theyre always on time, know their stuff, and even a hit with my dogs. If you want honest, reliable, high-quality service in St. Pete, these guys are the way to go!
Amelia Johnson - St. Petersburg, FL 33704
Response from Air Bros Air Conditioning & Electrical:

Thank you, Amelia, for your kind words and for being a loyal customer since 2017! We're glad to hear that Ricky has kept your unit running smoothly and that Justin was there to help during a tough time. It means a lot to us to know we can provide reliable service for you and your furry friends!

Review
Nathan helped me out on very short notice, super professional and polite. Definitely will call again if need arises.
Ante Gotovina - St. Petersburg, FL 33704
Response from Air Bros Air Conditioning & Electrical:

Thank you, Ante, for your kind words about Nathan's professionalism and quick assistance; we look forward to helping you again in the future!

Contact the Bros You Know Today!

Schedule Service Online
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at 727-217-6148 .

By pressing Submit I agree to receive phone, email, or text messages from Air Bros Air Conditioning & Heating to the provided mobile number and also agree to the Air Bros Air Conditioning & Heating terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next