Instant Quote Shop Filters Call Air Bros

Gulfport, FL

air-bros-team-with-truck

Your Gulfport, FL, HVAC Experts

Air Bros Air Conditioning & Heating proudly serves the charming waterfront city of Gulfport, FL. We understand the importance of reliable and efficient HVAC and electrical systems in this unique coastal environment, and we're dedicated to providing top-notch service to keep your Gulfport home comfortable year-round. Our team of experienced and certified technicians is committed to delivering personalized solutions that exceed your expectations.

Call us at 727-217-6148 or contact us online for help in Gulfport, FL.

Comprehensive HVAC Services in Gulfport

We offer a full range of heating and cooling services tailored to the needs of Gulfport residents:

  • Air Conditioning: Stay cool and comfortable all summer long with our AC repair, installation, and maintenance services. We can handle any AC issue, big or small, and offer same-day service for emergencies.
  • Heating: Keep your home warm and cozy in the winter with our comprehensive heating services, including repair, installation, and maintenance for all types of heating systems.
  • Indoor Air Quality: Breathe easier with our indoor air quality solutions, such as dehumidifier and UV light installations, which help control humidity and eliminate airborne contaminants.
  • Ductwork: Ensure optimal airflow and energy efficiency with our ductwork repair and installation services.
  • Pool Heater Services: Extend your swim season with our pool heater installation and repair services.
  • Electrical Services: We offer outlet and switch replacements, ceiling fan installations, and whole-house surge protector installations.

Why Choose Air Bros in Gulfport?

  • Your Gulfport HVAC Specialists: We're not just any HVAC company; we're your neighbors in Gulfport. We understand the specific challenges of this coastal community and the importance of reliable HVAC systems for your home.
  • Here When You Need Us: We offer same-day service for AC emergencies and prioritize prompt service for all your HVAC needs, ensuring you're never left uncomfortable for long.
  • Expert Technicians You Can Trust: Our team is highly trained and experienced in all aspects of HVAC service, guaranteeing top-quality workmanship on every job.
  • Honest and Transparent: We believe in upfront pricing with no hidden fees or surprises. You'll always know exactly what to expect.
  • Your Comfort is Our Priority: We're dedicated to exceeding your expectations and ensuring your complete satisfaction with our services and your home comfort.

Contact Air Bros Today!

Ready to experience the Air Bros difference? We're your one-stop shop for all your HVAC needs in Gulfport. Whether you're facing an AC emergency, need a new heating system installed, or simply want to schedule routine maintenance, our team is here to help. Contact us today for a free consultation and let us show you why we're the trusted choice for home comfort in Gulfport!

Call us at 727-217-6148 or contact us online for help in Gulfport, FL.

Count on perfect service; Trust the bros you know!

Recent Jobs and Reviews in Gulfport, FL

Job Locations and Reviews

Justin G.
Justin G. Checked in
On arrival found unit not cooling due to tripped float. Cleared pan and drain. Added pan tabs to system. Observed weak capacitor and low refrigerant. Filled unit back to factory specs and replaced weak capacitor. Pressures good. Temp split good. Unit draining and cooling properly at this time.
Gulfport, FL 33707
Home owner has concerns humidity and lack of air flow in some areas 

Found air handler holding water due to clogged drain line 

Found system low refrigerant (1.5lb) (previous contractor working on system) (explained we can charge system and monitor pressures)

Home owner asked about dryer venting, explained we do not offer dryer vent services 

Addition/enclosure master bedroom/bathroom lack of air flow. 

Found wholes in ducting and ducts lacking insulation. Some ducts have been taped. Air handler is furthers from these areas 

Explained in the winter time we can come back to design a duct system to meet there homes requirements. Also recommended we could add mini split to addition

Scope of work
-Cleared drain line and drain pan 
-add pan tablets/solution to help with buildup 
-Primed trap and drain 
-added 1.5lb 410a back to factory specifications 

Will return in colder months to go over ducting
Home owner has concerns humidity and lack of air flow in some areas 

Found air handler holding water due to clogged drain line 

Found system low refrigerant (1.5lb) (previous contractor working on system) (explained we can charge system and monitor pressures)

Home owner asked about dryer venting, explained we do not offer dryer vent services 

Addition/enclosure master bedroom/bathroom lack of air flow. 

Found wholes in ducting and ducts lacking insulation. Some ducts have been taped. Air handler is furthers from these areas 

Explained in the winter time we can come back to design a duct system to meet there homes requirements. Also recommended we could add mini split to addition

Scope of work
-Cleared drain line and drain pan 
-add pan tablets/solution to help with buildup 
-Primed trap and drain 
-added 1.5lb 410a back to factory specifications 

Will return in colder months to go over ducting
Nathan A.
Nathan A. Checked in
Home owner has concerns humidity and lack of air flow in some areas Found air handler holding water due to clogged drain line Found system low refrigerant (1.5lb) (previous contractor working on system) (explained we can charge system and monitor pressures) Home owner asked about dryer venting, explained we do not offer dryer vent services Addition/enclosure master bedroom/bathroom lack of air flow. Found wholes in ducting and ducts lacking insulation. Some ducts have been taped. Air handler is furthers from these areas Explained in the winter time we can come back to design a duct system to meet there homes requirements. Also recommended we could add mini split to addition Scope of work -Cleared drain line and drain pan -add pan tablets/solution to help with buildup -Primed trap and drain -added 1.5lb 410a back to factory specifications Will return in colder months to go over ducting
Gulfport, FL 33707
Gulfport, FL - Replace warranty outdoor suction temp sensor. Unit cooling properly.
Justin G.
Justin G. Checked in
Replace warranty outdoor suction temp sensor. Unit cooling properly.
Gulfport, FL 33707
Client installed Mr. cool mini split single zone system. Found system very low on refrigerant. Explained that we can do a leak search and repair depending on where the leak is but client would like to hold off and fix it himself. System is not cooling at this time. 

Client noted that he did not pull a vacuum when releasing the refrigerant in the lineset. I explained that noncondensables will shorten the lifespan of a system and not allow it to work properly.
Client installed Mr. cool mini split single zone system. Found system very low on refrigerant. Explained that we can do a leak search and repair depending on where the leak is but client would like to hold off and fix it himself. System is not cooling at this time. 

Client noted that he did not pull a vacuum when releasing the refrigerant in the lineset. I explained that noncondensables will shorten the lifespan of a system and not allow it to work properly.
Michael A.
Michael A. Checked in
Client installed Mr. cool mini split single zone system. Found system very low on refrigerant. Explained that we can do a leak search and repair depending on where the leak is but client would like to hold off and fix it himself. System is not cooling at this time. Client noted that he did not pull a vacuum when releasing the refrigerant in the lineset. I explained that noncondensables will shorten the lifespan of a system and not allow it to work properly.
Gulfport, FL 33707
Justin G.
Justin G. Checked in
Found unit cooling on arrival. Error code reflects faulty temp sensor. Unit is still operational. Will submit estimate for sensor replacement.
Gulfport, FL 33707
System not cooling. Found condenser fan motor seized up. 
Replaced fan motor and started system. System is cooling at this time. 
Amp draws are good. 
1 year warranty on motor
System not cooling. Found condenser fan motor seized up. 
Replaced fan motor and started system. System is cooling at this time. 
Amp draws are good. 
1 year warranty on motor
Michael A.
Michael A. Checked in
System not cooling. Found condenser fan motor seized up. Replaced fan motor and started system. System is cooling at this time. Amp draws are good. 1 year warranty on motor
Gulfport, FL 33707
Found system running but compressor not coming on. Sound bad capacitor. Replaced capacitor and contactor. Started system and found amp draws and temperature splits are within range. Temperature split is at 19°. Performed a complementary drain cleaning.
System is cooling and draining properly at this time.
Found system running but compressor not coming on. Sound bad capacitor. Replaced capacitor and contactor. Started system and found amp draws and temperature splits are within range. Temperature split is at 19°. Performed a complementary drain cleaning.
System is cooling and draining properly at this time.
Michael A.
Michael A. Checked in
Found system running but compressor not coming on. Sound bad capacitor. Replaced capacitor and contactor. Started system and found amp draws and temperature splits are within range. Temperature split is at 19°. Performed a complementary drain cleaning. System is cooling and draining properly at this time.
Gulfport, FL 33707
3.5 ton Ruud system 
14.3 seer 2
10 year parts warranty
3 year labor warranty 
-Shorty air handler 
-Permit
-Condenser on existing stand with vibration pads
-New electrical disconnect outside
-Reinsulate all copper outside with uv resistant armorflex
-Hurricane tiedowns
-New electrical whip
-Corrosion protection sprayed on condenser 
-Float switch
-Seal to existing plenum
-10kw heater
-Replace breakers as needed
-Uv light installed above coil
-Flush drain
-New Honeywell thermostat
-100% satisfaction guarantee
3.5 ton Ruud system 
14.3 seer 2
10 year parts warranty
3 year labor warranty 
-Shorty air handler 
-Permit
-Condenser on existing stand with vibration pads
-New electrical disconnect outside
-Reinsulate all copper outside with uv resistant armorflex
-Hurricane tiedowns
-New electrical whip
-Corrosion protection sprayed on condenser 
-Float switch
-Seal to existing plenum
-10kw heater
-Replace breakers as needed
-Uv light installed above coil
-Flush drain
-New Honeywell thermostat
-100% satisfaction guarantee
Kyle K.
Kyle K. Checked in
3.5 ton Ruud system 14.3 seer 2 10 year parts warranty 3 year labor warranty -Shorty air handler -Permit -Condenser on existing stand with vibration pads -New electrical disconnect outside -Reinsulate all copper outside with uv resistant armorflex -Hurricane tiedowns -New electrical whip -Corrosion protection sprayed on condenser -Float switch -Seal to existing plenum -10kw heater -Replace breakers as needed -Uv light installed above coil -Flush drain -New Honeywell thermostat -100% satisfaction guarantee
Gulfport, FL 33707
2 Year Goodman Heat Pumps (2 Systems)

Performed maintenance on both systems 

Systems are operating within manufacture specifications
2 Year Goodman Heat Pumps (2 Systems)

Performed maintenance on both systems 

Systems are operating within manufacture specifications
Nathan A.
Nathan A. Checked in
2 Year Goodman Heat Pumps (2 Systems) Performed maintenance on both systems Systems are operating within manufacture specifications
Gulfport, FL 33707
Redo both flare fittings at condenser
Perform pressure test 
Pull deep vacuum 
Recharge with 1.6 pounds of R32 

Warranty flare on Condneser repair for 1 year. 

Informed homeowner of regular cleaning on mini split every other year. 

Pressure test held at 286.0 for 10 min 
Pull vac down to 500 m 
Charged system with 2.9 of 32
Redo both flare fittings at condenser
Perform pressure test 
Pull deep vacuum 
Recharge with 1.6 pounds of R32 

Warranty flare on Condneser repair for 1 year. 

Informed homeowner of regular cleaning on mini split every other year. 

Pressure test held at 286.0 for 10 min 
Pull vac down to 500 m 
Charged system with 2.9 of 32
Corbin C.
Corbin C. Checked in
Redo both flare fittings at condenser Perform pressure test Pull deep vacuum Recharge with 1.6 pounds of R32 Warranty flare on Condneser repair for 1 year. Informed homeowner of regular cleaning on mini split every other year. Pressure test held at 286.0 for 10 min Pull vac down to 500 m Charged system with 2.9 of 32
Gulfport, FL 33707
Reason for call:
Mini split no cool 

Equipment:
2025 single zone Daikin 

Summary:
On arrival found system extremely low on refrigerant charge. Found leaking flare fitting at Condenser. Quoted to redo both fitting at condenser. Perform pressure test to confirm no other leaks. Pull deep vacuum in system recharge system with 1.6 pound of R32. 
Pressure we reading 117 standing
Reason for call:
Mini split no cool 

Equipment:
2025 single zone Daikin 

Summary:
On arrival found system extremely low on refrigerant charge. Found leaking flare fitting at Condenser. Quoted to redo both fitting at condenser. Perform pressure test to confirm no other leaks. Pull deep vacuum in system recharge system with 1.6 pound of R32. 
Pressure we reading 117 standing
Corbin C.
Corbin C. Checked in
Reason for call: Mini split no cool Equipment: 2025 single zone Daikin Summary: On arrival found system extremely low on refrigerant charge. Found leaking flare fitting at Condenser. Quoted to redo both fitting at condenser. Perform pressure test to confirm no other leaks. Pull deep vacuum in system recharge system with 1.6 pound of R32. Pressure we reading 117 standing
Gulfport, FL 33707
Ricky O.
Ricky O. Checked in
Client had bad blower motor but it was replaced by another company less than a year ago. Gave her price of 1,450$ she’s calling other company to see if they will warranty
Gulfport, FL 33707
Ruud 4 ton 15.2 seer2 heat pump split system with 5kw heater
Anchor condenser
Material lift
WiFi thermostat
Primary float switch
Media filter
Clear drain
Uv rated insulation for outdoor copper
Refrigerant locking caps
Remove existing equipment 
Connect to existing ducts and electrical 
Seal unit to code
Tax labor and permit included
10 year parts warranty 
3 year labor warranty
Ruud 4 ton 15.2 seer2 heat pump split system with 5kw heater
Anchor condenser
Material lift
WiFi thermostat
Primary float switch
Media filter
Clear drain
Uv rated insulation for outdoor copper
Refrigerant locking caps
Remove existing equipment 
Connect to existing ducts and electrical 
Seal unit to code
Tax labor and permit included
10 year parts warranty 
3 year labor warranty
Martin W.
Martin W. Checked in
Ruud 4 ton 15.2 seer2 heat pump split system with 5kw heater Anchor condenser Material lift WiFi thermostat Primary float switch Media filter Clear drain Uv rated insulation for outdoor copper Refrigerant locking caps Remove existing equipment Connect to existing ducts and electrical Seal unit to code Tax labor and permit included 10 year parts warranty 3 year labor warranty
Gulfport, FL 33707
We tried to schedule Maitenences twice before today’s visit. Found clogged drain line and faulty safety float switch today. 
Performed rest of Maitenence today. Amp draws, contactar, and capacitor are good. Temp split is 19°. Cleaned condenser coils.  System is cooling at this time
Replaced ss2 safety switch
Performed discounted drain cleaning.
We tried to schedule Maitenences twice before today’s visit. Found clogged drain line and faulty safety float switch today. 
Performed rest of Maitenence today. Amp draws, contactar, and capacitor are good. Temp split is 19°. Cleaned condenser coils.  System is cooling at this time
Replaced ss2 safety switch
Performed discounted drain cleaning.
Michael A.
Michael A. Checked in
We tried to schedule Maitenences twice before today’s visit. Found clogged drain line and faulty safety float switch today. Performed rest of Maitenence today. Amp draws, contactar, and capacitor are good. Temp split is 19°. Cleaned condenser coils. System is cooling at this time Replaced ss2 safety switch Performed discounted drain cleaning.
Gulfport, FL 33707
Reason for call:
Tune up turned into no cool 

Equipment:
2015 Goodman 3 ton straight cool 
Condenser on roof 
Air handler vertical in storage closet 

Summary:
On arrival found condenser breaker tripping. Unit not cooling. Found dead capacitor and found compressor stuck in start up.  Unit needs new capacitor and new starting components. Informed homeowner he wanted a quote for replacement. Provided repair and replacement quote to homeowner.
Reason for call:
Tune up turned into no cool 

Equipment:
2015 Goodman 3 ton straight cool 
Condenser on roof 
Air handler vertical in storage closet 

Summary:
On arrival found condenser breaker tripping. Unit not cooling. Found dead capacitor and found compressor stuck in start up.  Unit needs new capacitor and new starting components. Informed homeowner he wanted a quote for replacement. Provided repair and replacement quote to homeowner.
Corbin C.
Corbin C. Checked in
Reason for call: Tune up turned into no cool Equipment: 2015 Goodman 3 ton straight cool Condenser on roof Air handler vertical in storage closet Summary: On arrival found condenser breaker tripping. Unit not cooling. Found dead capacitor and found compressor stuck in start up. Unit needs new capacitor and new starting components. Informed homeowner he wanted a quote for replacement. Provided repair and replacement quote to homeowner.
Gulfport, FL 33707
Reason for call:
Condensate pump running more than normal. 

Equipment:
2 zone hunter and cooper mini split 

Summary:
Performed tune up in both mini split heads. To find them cooling very well. Confirmed proper pressures, temperatures. Flushed coils and drain line. Inspected blower wheels to find both units need to be cleaned. Found condone pump operating very well more water is being produced at the warm season arrives. 

Homeowner only wanted mini split and inspected not central unit.
Reason for call:
Condensate pump running more than normal. 

Equipment:
2 zone hunter and cooper mini split 

Summary:
Performed tune up in both mini split heads. To find them cooling very well. Confirmed proper pressures, temperatures. Flushed coils and drain line. Inspected blower wheels to find both units need to be cleaned. Found condone pump operating very well more water is being produced at the warm season arrives. 

Homeowner only wanted mini split and inspected not central unit.
Corbin C.
Corbin C. Checked in
Reason for call: Condensate pump running more than normal. Equipment: 2 zone hunter and cooper mini split Summary: Performed tune up in both mini split heads. To find them cooling very well. Confirmed proper pressures, temperatures. Flushed coils and drain line. Inspected blower wheels to find both units need to be cleaned. Found condone pump operating very well more water is being produced at the warm season arrives. Homeowner only wanted mini split and inspected not central unit.
Gulfport, FL 33707
Upon arrival, I spoke with the tenant regarding the reported issue. The tenant stated that the condensate drain line had backed up into the float switch the previous day, causing the system to shut down.

Before recommending any repairs or cleaning services, I performed a complete system diagnostic. The system is mechanically operating properly at this time. The refrigerant cycle is healthy with no signs of leaks or restrictions, the temperature differential is approximately 20°F and within the proper operating range, and all electrical components are functioning as designed.

Based on my findings, the issue appears to be related to the condensate drain system. I recommended an advanced drain line cleaning to thoroughly clear the line and help prevent future backups. However, since I was onsite approximately one month ago for a maintenance visit, I am offering the service at the Tier 1 cleaning rate.

Once the cleaning is completed, I can confidently verify that the drain line is clear
Upon arrival, I spoke with the tenant regarding the reported issue. The tenant stated that the condensate drain line had backed up into the float switch the previous day, causing the system to shut down.

Before recommending any repairs or cleaning services, I performed a complete system diagnostic. The system is mechanically operating properly at this time. The refrigerant cycle is healthy with no signs of leaks or restrictions, the temperature differential is approximately 20°F and within the proper operating range, and all electrical components are functioning as designed.

Based on my findings, the issue appears to be related to the condensate drain system. I recommended an advanced drain line cleaning to thoroughly clear the line and help prevent future backups. However, since I was onsite approximately one month ago for a maintenance visit, I am offering the service at the Tier 1 cleaning rate.

Once the cleaning is completed, I can confidently verify that the drain line is clear
ihsan m.
ihsan m. Checked in
Upon arrival, I spoke with the tenant regarding the reported issue. The tenant stated that the condensate drain line had backed up into the float switch the previous day, causing the system to shut down. Before recommending any repairs or cleaning services, I performed a complete system diagnostic. The system is mechanically operating properly at this time. The refrigerant cycle is healthy with no signs of leaks or restrictions, the temperature differential is approximately 20°F and within the proper operating range, and all electrical components are functioning as designed. Based on my findings, the issue appears to be related to the condensate drain system. I recommended an advanced drain line cleaning to thoroughly clear the line and help prevent future backups. However, since I was onsite approximately one month ago for a maintenance visit, I am offering the service at the Tier 1 cleaning rate. Once the cleaning is completed, I can confidently verify that the drain line is clear
Gulfport, FL 33707
Replace evap coil, replace stat
Proper operation was restored to equipment.
Replace evap coil, replace stat
Proper operation was restored to equipment.
Corbin C.
Corbin C. Checked in
Replace evap coil, replace stat Proper operation was restored to equipment.
Gulfport, FL 33707
Found leaky evap coil. Client does not want to replace system due to them selling the home. Replacing coil on monday
Found leaky evap coil. Client does not want to replace system due to them selling the home. Replacing coil on monday
Ricky O.
Ricky O. Checked in
Found leaky evap coil. Client does not want to replace system due to them selling the home. Replacing coil on monday
Gulfport, FL 33707
Upon arrival, I checked the temperature difference between the supply and return air and recorded a 17° split. I then proceeded with a full electrical inspection and found all electrical components functioning properly with no signs of shorts, burnouts, or over-amperage conditions.

I performed a drain line treatment, cleaned the condenser coil, and completed an inspection of the air handler. During the inspection, I noticed the blower wheel has buildup/impact from dust accumulation. I recommended a blower wheel cleaning (pollen clean) to improve airflow and system efficiency; however, the homeowners chose to hold off on the service at this time.

If you have any questions, please feel free to reach out. Thank you for your business, and have a great day.
Upon arrival, I checked the temperature difference between the supply and return air and recorded a 17° split. I then proceeded with a full electrical inspection and found all electrical components functioning properly with no signs of shorts, burnouts, or over-amperage conditions.

I performed a drain line treatment, cleaned the condenser coil, and completed an inspection of the air handler. During the inspection, I noticed the blower wheel has buildup/impact from dust accumulation. I recommended a blower wheel cleaning (pollen clean) to improve airflow and system efficiency; however, the homeowners chose to hold off on the service at this time.

If you have any questions, please feel free to reach out. Thank you for your business, and have a great day.
ihsan m.
ihsan m. Checked in
Upon arrival, I checked the temperature difference between the supply and return air and recorded a 17° split. I then proceeded with a full electrical inspection and found all electrical components functioning properly with no signs of shorts, burnouts, or over-amperage conditions. I performed a drain line treatment, cleaned the condenser coil, and completed an inspection of the air handler. During the inspection, I noticed the blower wheel has buildup/impact from dust accumulation. I recommended a blower wheel cleaning (pollen clean) to improve airflow and system efficiency; however, the homeowners chose to hold off on the service at this time. If you have any questions, please feel free to reach out. Thank you for your business, and have a great day.
Gulfport, FL 33711
Justin G.
Justin G. Checked in
On arrival found condensate pump fitting broke and leaking water in return. Replaced pump. Changed electric to match new pump. Connected float. Start and test. Pump operating properly. Unit cooling at this time.
Gulfport, FL 33707
Install New Air Handler Coil Under Manufacturer Warranty 

Pulled vacuum and pressure test 

Charged system to manufacture specifications 

Unit is currently operating within manufacture specifications
Install New Air Handler Coil Under Manufacturer Warranty 

Pulled vacuum and pressure test 

Charged system to manufacture specifications 

Unit is currently operating within manufacture specifications
Nathan A.
Nathan A. Checked in
Install New Air Handler Coil Under Manufacturer Warranty Pulled vacuum and pressure test Charged system to manufacture specifications Unit is currently operating within manufacture specifications
Gulfport, FL 33707
Replacement of two 6 in flex runs
One located off mixing box feeding master bed has huge hole 
One located off mixing box feeding back room 
Bring 2 full bags of 6in reuse collars
Replacement of two 6 in flex runs
One located off mixing box feeding master bed has huge hole 
One located off mixing box feeding back room 
Bring 2 full bags of 6in reuse collars
Martin W.
Martin W. Checked in
Replacement of two 6 in flex runs One located off mixing box feeding master bed has huge hole One located off mixing box feeding back room Bring 2 full bags of 6in reuse collars
Gulfport, FL 33707
Completed tune up to find operation of unit within manufacturing specifications. Found blower wheel has biological growth, no primary float switch, duct work is not strap properly, 4 in run has collapsed on itself. 
Unit is operating there repairs will improve the operation, efficiency, and life expectancy of equipment.
Completed tune up to find operation of unit within manufacturing specifications. Found blower wheel has biological growth, no primary float switch, duct work is not strap properly, 4 in run has collapsed on itself. 
Unit is operating there repairs will improve the operation, efficiency, and life expectancy of equipment.
Nathan A.
Nathan A. Checked in
Completed tune up to find operation of unit within manufacturing specifications. Found blower wheel has biological growth, no primary float switch, duct work is not strap properly, 4 in run has collapsed on itself. Unit is operating there repairs will improve the operation, efficiency, and life expectancy of equipment.
Gulfport, FL 33707
Upon arrival tenant states unit is not cooling. Found outdoor board had failed. Bypassed board and system began to run. Found thermostat shorting across heat terminal causing system to run in heat. 

Found large hole in 6” flex duct in attic (potential rodent)

Recommendations 
-outdoor contactor pitted and rusted 
-outdoor compressor capacitor reading out of specs 
-outdoor coils impacted with dirt/debris 
-no primary overflow safety on air handler (potential water damage)
-Thermosat needs to be replaced (shorted)

Went over concern with homeowner. Also went over basic maintenance with tenant (filters etc)

Would recommend adding surge protectors to avoid this issue 

Unit is currently cooling but will need to get board from supplier. Will not run in heat until thermostat replaced. 


Casey (Tenant)

860-961-8493
Upon arrival tenant states unit is not cooling. Found outdoor board had failed. Bypassed board and system began to run. Found thermostat shorting across heat terminal causing system to run in heat. 

Found large hole in 6” flex duct in attic (potential rodent)

Recommendations 
-outdoor contactor pitted and rusted 
-outdoor compressor capacitor reading out of specs 
-outdoor coils impacted with dirt/debris 
-no primary overflow safety on air handler (potential water damage)
-Thermosat needs to be replaced (shorted)

Went over concern with homeowner. Also went over basic maintenance with tenant (filters etc)

Would recommend adding surge protectors to avoid this issue 

Unit is currently cooling but will need to get board from supplier. Will not run in heat until thermostat replaced. 


Casey (Tenant)

860-961-8493
Nathan A.
Nathan A. Checked in
Upon arrival tenant states unit is not cooling. Found outdoor board had failed. Bypassed board and system began to run. Found thermostat shorting across heat terminal causing system to run in heat. Found large hole in 6” flex duct in attic (potential rodent) Recommendations -outdoor contactor pitted and rusted -outdoor compressor capacitor reading out of specs -outdoor coils impacted with dirt/debris -no primary overflow safety on air handler (potential water damage) -Thermosat needs to be replaced (shorted) Went over concern with homeowner. Also went over basic maintenance with tenant (filters etc) Would recommend adding surge protectors to avoid this issue Unit is currently cooling but will need to get board from supplier. Will not run in heat until thermostat replaced. Casey (Tenant) 860-961-8493
Gulfport, FL 33707