Instant Quote Shop Filters Call Air Bros Book Service

St. Pete Beach, FL

air-bros-team-with-truck

Your Coastal HVAC Specialists

Air Bros Air Conditioning & Heating is your trusted source for reliable and efficient HVAC solutions in the beautiful coastal community of St. Pete Beach, FL. We understand the unique challenges that beachfront properties face, from salty air and high humidity to the need for robust cooling systems to combat the Florida heat. Our team of experienced technicians is dedicated to providing top-quality HVAC services tailored to the specific needs of St. Pete Beach residents and businesses.

Call us at 727-217-6148 or contact us online for help in St. Pete Beach, FL.

Your Comfort, Our Priority in St. Pete Beach

At Air Bros, we're dedicated to keeping your St. Pete Beach home comfortable year-round, no matter what Florida's weather brings. We offer a comprehensive range of HVAC services tailored to the unique needs of coastal living:

  • Stay Cool & Comfortable: Beat the heat with our expert AC services. We handle everything from minor repairs to full system installations, and we offer same-day service for those unexpected AC emergencies.
  • Warm & Cozy Winters: Even in Florida, winter nights can get chilly. Our heating services ensure your home stays warm and inviting, with repairs, installations, and maintenance for all types of heating systems.
  • Breathe Easy: Improve your indoor air quality with our solutions designed to control humidity and eliminate airborne contaminants. We install and service dehumidifiers and UV light air purifiers to create a healthier home environment.
  • Optimize Your Airflow: Ensure your HVAC system is running efficiently with our ductwork services. We can repair or replace your ductwork to maximize airflow and energy efficiency.

Our experienced and certified technicians are committed to providing top-quality workmanship and customer care on every job.

Why Choose Air Bros in St. Pete Beach?

  • Coastal Expertise: We understand the unique challenges of maintaining HVAC systems in coastal environments.
  • Fast and Reliable Service: We offer same-day service for AC emergencies and prioritize prompt service for all your HVAC needs.
  • Experienced Technicians: Our team is highly trained and experienced in all aspects of HVAC service.
  • Upfront Pricing: We provide transparent pricing with no hidden costs.
  • Customer Satisfaction Guaranteed: Your comfort and satisfaction are our top priorities.

Contact Air Bros Today!

Whether you need emergency AC repair, a new heating system installation, or any other HVAC service, Air Bros is here to help. Contact us today for a free consultation or to schedule a service appointment. We're proud to be your trusted HVAC partner in St. Pete Beach!

Call us at 727-217-6148 or contact us online for help in St. Pete Beach, FL.

Count on perfect service; Trust the bros you know!

Recent Jobs and Reviews in St. Pete Beach, Saint Pete Beach, FL

Job Locations and Reviews

Performed Maitenences on systems. Cleaned/treated drain lines and primary drain pans. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switchs functionality. Checked amp draw on compressors. Checked amp draw on fan motors. Checked capacitors are within factory range. Made sure all connections are tight. Systems are cooling with 20° temperature splits at this time. Verified systems heat properly. 

System #1 main level: *11 years old*
- Found burnt up and corroded wires at the capacitor and contactar terminals. 
- Condenser fan motor is over amping and at risk of failure

System #2 upstairs: *9 years old*
- condensate pump severely clogged
- Blower wheel has heavy microbial growth which is putting excess stress on the fan motor. 
- UV system inside Unit is no longer working. Recommending full replacement. 

Replaced compressor capacitor
Replaced Contactor
Replaced burnt up wires and connectors
Tested system after repair 

Signed client up for 3 system Maitenenc
Performed Maitenences on systems. Cleaned/treated drain lines and primary drain pans. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switchs functionality. Checked amp draw on compressors. Checked amp draw on fan motors. Checked capacitors are within factory range. Made sure all connections are tight. Systems are cooling with 20° temperature splits at this time. Verified systems heat properly. 

System #1 main level: *11 years old*
- Found burnt up and corroded wires at the capacitor and contactar terminals. 
- Condenser fan motor is over amping and at risk of failure

System #2 upstairs: *9 years old*
- condensate pump severely clogged
- Blower wheel has heavy microbial growth which is putting excess stress on the fan motor. 
- UV system inside Unit is no longer working. Recommending full replacement. 

Replaced compressor capacitor
Replaced Contactor
Replaced burnt up wires and connectors
Tested system after repair 

Signed client up for 3 system Maitenenc
Michael A.
Michael A. Checked in
Performed Maitenences on systems. Cleaned/treated drain lines and primary drain pans. Cleaned condenser coils. Evaporator coils are clean. Verified safety float switchs functionality. Checked amp draw on compressors. Checked amp draw on fan motors. Checked capacitors are within factory range. Made sure all connections are tight. Systems are cooling with 20° temperature splits at this time. Verified systems heat properly. System #1 main level: *11 years old* - Found burnt up and corroded wires at the capacitor and contactar terminals. - Condenser fan motor is over amping and at risk of failure System #2 upstairs: *9 years old* - condensate pump severely clogged - Blower wheel has heavy microbial growth which is putting excess stress on the fan motor. - UV system inside Unit is no longer working. Recommending full replacement. Replaced compressor capacitor Replaced Contactor Replaced burnt up wires and connectors Tested system after repair Signed client up for 3 system Maitenenc
St. Pete Beach, FL 33706
Griffin K.
Griffin K. Checked in
Troubleshoot the kitchen outlets Found a loose neutral connections tightened all connections and cleared the issue
St. Pete Beach, FL 33706
On arrival found unit not cooling due to weak condensate pump causing float to trip. Will submit estimate for condensate pump and drain replacement. Living room unit does not cooling due at this time.
On arrival found unit not cooling due to weak condensate pump causing float to trip. Will submit estimate for condensate pump and drain replacement. Living room unit does not cooling due at this time.
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to weak condensate pump causing float to trip. Will submit estimate for condensate pump and drain replacement. Living room unit does not cooling due at this time.
St. Pete Beach, FL 33706
Removed condenser and pad from home. Recovered refrigerant and disconnected electrical. Taped off line set to prevent moisture intrusion. Tax and labor included.
Removed condenser and pad from home. Recovered refrigerant and disconnected electrical. Taped off line set to prevent moisture intrusion. Tax and labor included.
Justin G.
Justin G. Checked in
Removed condenser and pad from home. Recovered refrigerant and disconnected electrical. Taped off line set to prevent moisture intrusion. Tax and labor included.
St. Pete Beach, FL 33706
Replace ceiling cassette
Start and test. Unit cooling properly at this time.
Replace ceiling cassette
Start and test. Unit cooling properly at this time.
Justin G.
Justin G. Checked in
Replace ceiling cassette Start and test. Unit cooling properly at this time.
St. Pete Beach, FL 33706
Middle Floor Unit Not Heating 

4 Head Cassette Single Trane/Mitsubishi Condenser 

System is low on refrigerant. Leak search already performed and system filled. Will need to replace cassette. 

Declined filling system 

Left system off so no further damage
Middle Floor Unit Not Heating 

4 Head Cassette Single Trane/Mitsubishi Condenser 

System is low on refrigerant. Leak search already performed and system filled. Will need to replace cassette. 

Declined filling system 

Left system off so no further damage
Nathan A.
Nathan A. Checked in
Middle Floor Unit Not Heating 4 Head Cassette Single Trane/Mitsubishi Condenser System is low on refrigerant. Leak search already performed and system filled. Will need to replace cassette. Declined filling system Left system off so no further damage
St. Pete Beach, FL 33706
Upon my inspection, found blown 5amp fuse in air handler. Performed a low vintage short diagnosis. Found that the existing broken UV lamp was causing the fuse to blow. Replaced Uv system and turned system back on. Thermostat took a really long time to boot back up and call for cooling (about 30 mins). When system stayed up, verified operations and found weak capacitor. Replaced capacitor. Performed Maitenence on system. System is cooling at this time with a 20° temperature split.
Upon my inspection, found blown 5amp fuse in air handler. Performed a low vintage short diagnosis. Found that the existing broken UV lamp was causing the fuse to blow. Replaced Uv system and turned system back on. Thermostat took a really long time to boot back up and call for cooling (about 30 mins). When system stayed up, verified operations and found weak capacitor. Replaced capacitor. Performed Maitenence on system. System is cooling at this time with a 20° temperature split.
Michael A.
Michael A. Checked in
Upon my inspection, found blown 5amp fuse in air handler. Performed a low vintage short diagnosis. Found that the existing broken UV lamp was causing the fuse to blow. Replaced Uv system and turned system back on. Thermostat took a really long time to boot back up and call for cooling (about 30 mins). When system stayed up, verified operations and found weak capacitor. Replaced capacitor. Performed Maitenence on system. System is cooling at this time with a 20° temperature split.
St. Pete Beach, FL 33706
Remove Current Trunk Line (Kitchen)
Run Duct-board Against Back Wall (High and Tight)
Duct Board to Living Room Transition 
Ductboard to Kitchen Transition 
Ductboard to Bathroom Transition (Flush Against Wall)
4” Bathroom Duct & Collar Ran Behind Studs (Mounting Fan Flush)
White Ceiling Registers 
Seal & Strap Ducting
Remove Current Trunk Line (Kitchen)
Run Duct-board Against Back Wall (High and Tight)
Duct Board to Living Room Transition 
Ductboard to Kitchen Transition 
Ductboard to Bathroom Transition (Flush Against Wall)
4” Bathroom Duct & Collar Ran Behind Studs (Mounting Fan Flush)
White Ceiling Registers 
Seal & Strap Ducting
Kyle K.
Kyle K. Checked in
Remove Current Trunk Line (Kitchen) Run Duct-board Against Back Wall (High and Tight) Duct Board to Living Room Transition Ductboard to Kitchen Transition Ductboard to Bathroom Transition (Flush Against Wall) 4” Bathroom Duct & Collar Ran Behind Studs (Mounting Fan Flush) White Ceiling Registers Seal & Strap Ducting
St. Pete Beach, FL 33706
Justin G.
Justin G. Checked in
Performed maintenance on 1 system. Unit cooling properly. Recommend for living room adding mini split to help cool due to lack of insulation.
St. Pete Beach, FL 33706
Justin G.
Justin G. Checked in
Performed inspection of hvac for high electric bill. Found thermostat set to fan on which allows the blower to run continuously. Evap coil and blower is dirty and will decrease efficiency. Outdoor unit coil is dirty as well. Ductwork is original sheet metal ducts and are leaking air and losing efficiency. Performed cleanings on system. Start and test. Unit cooling properly at this time.
St. Pete Beach, FL 33706
Ricky O.
Ricky O. Checked in
Cleaned drain line and pan on 2 mini splits
St. Pete Beach, FL 33706
On arrival inspected unit. Evan coil is extremely impacted and does not allow proper airflow through. Unit is a 2004 r22. Condenser is in very poor shape as well. Recommend to replace system due to age and condition. Unit is cooling to the best of its ability at this time.
On arrival inspected unit. Evan coil is extremely impacted and does not allow proper airflow through. Unit is a 2004 r22. Condenser is in very poor shape as well. Recommend to replace system due to age and condition. Unit is cooling to the best of its ability at this time.
Justin G.
Justin G. Checked in
On arrival inspected unit. Evan coil is extremely impacted and does not allow proper airflow through. Unit is a 2004 r22. Condenser is in very poor shape as well. Recommend to replace system due to age and condition. Unit is cooling to the best of its ability at this time.
St. Pete Beach, FL 33706
Install Single 12k BTU Head 
Remote/App Operated 
Install Wall Mounting Bracket 
Hurricane Tie Down Straps
Vibration Pads
New Refrigerant Lines
New Communication Wire
Install Hard Pipe PVC Drain
Install Exterior Line Covers
Install Multi Zone Outdoor Condenser 
Seal Penetration Points 
Pressure Test Systems 
Vacuum Systems 
Charge Systems 
UV Rated Outdoor Insulation 
Refrigerant Locking Caps
Permitting  
10 Year Parts Warranty 
3 Year Labor Warranty 

*Keep 9k BTU office head unit 
*Keep high voltage (electrical disconnect/whip)
Install Single 12k BTU Head 
Remote/App Operated 
Install Wall Mounting Bracket 
Hurricane Tie Down Straps
Vibration Pads
New Refrigerant Lines
New Communication Wire
Install Hard Pipe PVC Drain
Install Exterior Line Covers
Install Multi Zone Outdoor Condenser 
Seal Penetration Points 
Pressure Test Systems 
Vacuum Systems 
Charge Systems 
UV Rated Outdoor Insulation 
Refrigerant Locking Caps
Permitting  
10 Year Parts Warranty 
3 Year Labor Warranty 

*Keep 9k BTU office head unit 
*Keep high voltage (electrical disconnect/whip)
Kyle K.
Kyle K. Checked in
Install Single 12k BTU Head Remote/App Operated Install Wall Mounting Bracket Hurricane Tie Down Straps Vibration Pads New Refrigerant Lines New Communication Wire Install Hard Pipe PVC Drain Install Exterior Line Covers Install Multi Zone Outdoor Condenser Seal Penetration Points Pressure Test Systems Vacuum Systems Charge Systems UV Rated Outdoor Insulation Refrigerant Locking Caps Permitting 10 Year Parts Warranty 3 Year Labor Warranty *Keep 9k BTU office head unit *Keep high voltage (electrical disconnect/whip)
St. Pete Beach, FL 33706
Upon my inspection, I found system turning on and off intermittently. At the air handler, I found an improper drainage service port that is allowing air to be sucked into drain line. The main issue I found is the filter in the ceiling was severely impacted with debris and not allowing proper air flow. This was causing the drainage to back up in the system due to an air flow vacuum. Replaced filter and system is cooling at this time. Found a large leak in the supply plenum connected to the unit which is dumping cold air into the attic. System is cooling but not cooling efficiently until the air flow issue is addressed. Temp split is 10°. Also recommended drain line clean and treatment. 
Client did not opt to perform any additional work today.
Upon my inspection, I found system turning on and off intermittently. At the air handler, I found an improper drainage service port that is allowing air to be sucked into drain line. The main issue I found is the filter in the ceiling was severely impacted with debris and not allowing proper air flow. This was causing the drainage to back up in the system due to an air flow vacuum. Replaced filter and system is cooling at this time. Found a large leak in the supply plenum connected to the unit which is dumping cold air into the attic. System is cooling but not cooling efficiently until the air flow issue is addressed. Temp split is 10°. Also recommended drain line clean and treatment. 
Client did not opt to perform any additional work today.
Michael A.
Michael A. Checked in
Upon my inspection, I found system turning on and off intermittently. At the air handler, I found an improper drainage service port that is allowing air to be sucked into drain line. The main issue I found is the filter in the ceiling was severely impacted with debris and not allowing proper air flow. This was causing the drainage to back up in the system due to an air flow vacuum. Replaced filter and system is cooling at this time. Found a large leak in the supply plenum connected to the unit which is dumping cold air into the attic. System is cooling but not cooling efficiently until the air flow issue is addressed. Temp split is 10°. Also recommended drain line clean and treatment. Client did not opt to perform any additional work today.
St. Pete Beach, FL 33706
Install Single 12k BTU Head 
Remote/App Operated 
Install Wall Mounting Bracket 
Hurricane Tie Down Straps
Vibration Pads
New Refrigerant Lines
New Communication Wire
Install Hard Pipe PVC Drain
Install Exterior Line Covers
Install Single 12k Outdoor Condenser 
Seal Penetration Points 
Pressure Test Systems 
Vacuum Systems 
Charge Systems 
UV Rated Outdoor Insulation 
Refrigerant Locking Caps
Electrical to Panel/Breaker
Outdoor Surge Protection 
New Outdoor Electrical Whip
New Outdoor Electrical Disconnect
Permitting 
10 Year Parts Warranty 
3 Year Labor Warranty
Install Single 12k BTU Head 
Remote/App Operated 
Install Wall Mounting Bracket 
Hurricane Tie Down Straps
Vibration Pads
New Refrigerant Lines
New Communication Wire
Install Hard Pipe PVC Drain
Install Exterior Line Covers
Install Single 12k Outdoor Condenser 
Seal Penetration Points 
Pressure Test Systems 
Vacuum Systems 
Charge Systems 
UV Rated Outdoor Insulation 
Refrigerant Locking Caps
Electrical to Panel/Breaker
Outdoor Surge Protection 
New Outdoor Electrical Whip
New Outdoor Electrical Disconnect
Permitting 
10 Year Parts Warranty 
3 Year Labor Warranty
Kyle K.
Kyle K. Checked in
Install Single 12k BTU Head Remote/App Operated Install Wall Mounting Bracket Hurricane Tie Down Straps Vibration Pads New Refrigerant Lines New Communication Wire Install Hard Pipe PVC Drain Install Exterior Line Covers Install Single 12k Outdoor Condenser Seal Penetration Points Pressure Test Systems Vacuum Systems Charge Systems UV Rated Outdoor Insulation Refrigerant Locking Caps Electrical to Panel/Breaker Outdoor Surge Protection New Outdoor Electrical Whip New Outdoor Electrical Disconnect Permitting 10 Year Parts Warranty 3 Year Labor Warranty
St. Pete Beach, FL 33706
Upon arrival home owner states unit is intermittently cooling. Found drain line backed up causing safety to trip. Cleared drain line and pan. Added pan tabs to help with buildup. Verified system operations after repair. Unit is cooling properly. 

Drain is piped into home (possibly a bathroom or sink) no exterior drain 

Waived 95$ for membership
Upon arrival home owner states unit is intermittently cooling. Found drain line backed up causing safety to trip. Cleared drain line and pan. Added pan tabs to help with buildup. Verified system operations after repair. Unit is cooling properly. 

Drain is piped into home (possibly a bathroom or sink) no exterior drain 

Waived 95$ for membership
Nathan A.
Nathan A. Checked in
Upon arrival home owner states unit is intermittently cooling. Found drain line backed up causing safety to trip. Cleared drain line and pan. Added pan tabs to help with buildup. Verified system operations after repair. Unit is cooling properly. Drain is piped into home (possibly a bathroom or sink) no exterior drain Waived 95$ for membership
St. Pete Beach, FL 33706
Justin G.
Justin G. Checked in
Replace PCB and inverter control boards
St. Pete Beach, FL 33706
For condenser on roof- contactor is pitted with high resistance. Capacitor is weak. Allowing the system to run with a pitted contactor can damage the compressor with voltage drops. Fan motor has to work harder to start with weak capacitor.

Replaced contactor and capacitor. Tested system function after repair.
For condenser on roof- contactor is pitted with high resistance. Capacitor is weak. Allowing the system to run with a pitted contactor can damage the compressor with voltage drops. Fan motor has to work harder to start with weak capacitor.

Replaced contactor and capacitor. Tested system function after repair.
Sha’nya B.
Sha’nya B. Checked in
For condenser on roof- contactor is pitted with high resistance. Capacitor is weak. Allowing the system to run with a pitted contactor can damage the compressor with voltage drops. Fan motor has to work harder to start with weak capacitor. Replaced contactor and capacitor. Tested system function after repair.
St. Pete Beach, FL 33706
Precision tune up
Checked refrigerant pressures and air temp split. Air handler interior is dirty- provided estimates but homeowner does not want to move forward with cleanings at this time. Tested float switch. Flushed and treated drain pan/ line. Filter is recently changed. At condenser- cleaned out debris. Compressor capacitor reading is good. Contactor is pitted with high resistance. Capacitor for fan motor is weak- homeowner would like to replace capacitor and contactor. Need to schedule return visit for repair. All other system functions are in working order at this time. Signed up for maintenance membership.
Precision tune up
Checked refrigerant pressures and air temp split. Air handler interior is dirty- provided estimates but homeowner does not want to move forward with cleanings at this time. Tested float switch. Flushed and treated drain pan/ line. Filter is recently changed. At condenser- cleaned out debris. Compressor capacitor reading is good. Contactor is pitted with high resistance. Capacitor for fan motor is weak- homeowner would like to replace capacitor and contactor. Need to schedule return visit for repair. All other system functions are in working order at this time. Signed up for maintenance membership.
Sha’nya B.
Sha’nya B. Checked in
Precision tune up Checked refrigerant pressures and air temp split. Air handler interior is dirty- provided estimates but homeowner does not want to move forward with cleanings at this time. Tested float switch. Flushed and treated drain pan/ line. Filter is recently changed. At condenser- cleaned out debris. Compressor capacitor reading is good. Contactor is pitted with high resistance. Capacitor for fan motor is weak- homeowner would like to replace capacitor and contactor. Need to schedule return visit for repair. All other system functions are in working order at this time. Signed up for maintenance membership.
St. Pete Beach, FL 33706
Found leak on cassette coil in spare bedroom. No other leaks in system. Cooling for now. Sending quote to replace cassette
Found leak on cassette coil in spare bedroom. No other leaks in system. Cooling for now. Sending quote to replace cassette
Ricky O.
Ricky O. Checked in
Found leak on cassette coil in spare bedroom. No other leaks in system. Cooling for now. Sending quote to replace cassette
St. Pete Beach, FL 33706
Ricky O.
Ricky O. Checked in
Adding 2lbs of refrigerant now. Returning Tuesday for thorough leak check
St. Pete Beach, FL 33706
Justin G.
Justin G. Checked in
Performed extensive leak search on system. Checked outdoor and indoor coils and line set. Did not observe any leaks at this time. Add refrigerant back to factory specs. Will monitor system. Unit is cooling properly at this time.
St. Pete Beach, FL 33706
Justin G.
Justin G. Checked in
On arrival found unit not cooling due to low refrigerant. Will return to perform leak search for $350 next week. Unit is not cooling at this time.
St. Pete Beach, FL 33706
Kyle K.
Kyle K. Checked in
Installation of Mitsubishi 2 head condenser -Raise condenser to clients desired height -Connect to existing refrigerant line and comm wire -Vacuum lineset -Tiedown condenser to existing bracket -Run new electrical whip if it doesn't reach new location -Test system
St. Pete Beach, FL 33706

Contact the Bros You Know Today!

Schedule Service Online
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at 727-217-6148 .

By pressing Submit I agree to receive phone, email, or text messages from Air Bros Air Conditioning & Heating to the provided mobile number and also agree to the Air Bros Air Conditioning & Heating terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next